1
|
Mitsuhashi S, Kamal F, Shinn BJ, Chalikonda D, Tyberg A, Shahid H, Sarkar A, Kahaleh M, Chiang A, Kumar A, Schlachterman A, Loren D, Kowalski T. Colonic-enteric lumen-apposing metal stents: a promising and safe alternative for endoscopic management of small-bowel obstruction. Gastrointest Endosc 2024; 99:606-613. [PMID: 37951278 DOI: 10.1016/j.gie.2023.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Revised: 11/03/2023] [Accepted: 11/06/2023] [Indexed: 11/13/2023]
Abstract
BACKGROUND AND AIMS Lumen-apposing metal stents (LAMSs) have revolutionized the treatment of various gastroenterologic conditions that previously required surgery. The use of LAMSs for the management of small-bowel obstruction (SBO) involves EUS-guided coloenterostomy (EUS-CE) between the colon and a dilated loop of the small intestine proximal to the point of obstruction. This procedure is potentially beneficial for patients with malignant SBO who are poor surgical candidates. METHODS A retrospective cohort study was conducted at 2 tertiary care hospitals. Patients who underwent EUS-CE for SBO were identified, and data regarding patient demographics, indication for the procedure, location of the obstruction, procedural details, and adverse events were collected. The primary outcome was technical success of the procedure. Secondary outcomes were clinical success, resolution of symptoms, ability to tolerate enteral nutrition, and adverse events. RESULTS Twenty-six patients who underwent the EUS-CE procedure were included. Technical success was achieved in all 26 patients, clinical success (resolution of obstructive symptoms) was achieved in 92.3% of patients (24/26), and the ability to resume enteral nutrition in 84.6% (22/26). Adverse events occurred in 4 patients (15.4%) and included bleeding (1/26), diarrhea (2/26), and postprocedure sepsis (1/26). Patients were followed for a mean of 54.8 days (range, 2-190). CONCLUSIONS This study highlights that EUS-CE with LAMSs can be performed with high technical and clinical success for the management of SBO, particularly in patients with malignant obstructions who are not suitable candidates for surgical interventions. Further research with larger sample sizes will be essential to substantiate its efficacy and safety.
Collapse
Affiliation(s)
- Shuji Mitsuhashi
- Department of Medicine, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Faisal Kamal
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Brianna J Shinn
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Divya Chalikonda
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Amy Tyberg
- Department of Medicine, Division of Gastroenterology and Hepatology, Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA
| | - Haroon Shahid
- Department of Medicine, Division of Gastroenterology and Hepatology, Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA
| | - Avik Sarkar
- Department of Medicine, Division of Gastroenterology and Hepatology, Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA
| | - Michel Kahaleh
- Department of Medicine, Division of Gastroenterology and Hepatology, Robert Wood Johnson University Hospital, New Brunswick, New Jersey, USA
| | - Austin Chiang
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Anand Kumar
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Alex Schlachterman
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - David Loren
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| | - Thomas Kowalski
- Department of Medicine, Division of Gastroenterology and Hepatology, Thomas Jefferson University Hospital, Philadelphia, Pennsylvania, USA
| |
Collapse
|
2
|
Zhang J, Bao Y. Value of MSCT plus MRI in the Detection of Colon Cancer. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE : ECAM 2022; 2022:6507865. [PMID: 35685721 PMCID: PMC9173996 DOI: 10.1155/2022/6507865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Revised: 05/05/2022] [Accepted: 05/11/2022] [Indexed: 11/18/2022]
Abstract
Colon cancer is a common digestive system malignancy with nonspecific early symptoms, which necessitates better early detection methods. The present study was conducted to assess the accuracy and clinical value of multislice spiral CT (MSCT) plus magnetic resonance imaging (MRI) for colon cancer. Between January 2019 and July 2020, 100 patients with pathologically confirmed colon cancer treated in Wuxi People's Hospital were assessed for eligibility and recruited. All eligible patients received MRI and MSCT without any treatment prior to scanning. The accuracy of preoperative diagnosis and staging of colon cancer by MRI, MSCT, and MRI plus MSCT were analyzed using postoperative pathological results as the gold standard, and consistency analysis was performed. The receiver operating characteristic curve (ROC) was plotted, and the area under the curve (AUC) was obtained to analyze the preoperative diagnostic value. The accuracy of MRI, MSCT, and MRI plus MSCT was 98.00%, 96.00%, and 100% with good consistency (Kappa = 0.732, 0.703, and 0.756). The AUC of MRI, MSCT, and MRI plus MSCT was 0.889, 0.861, and 0.903, respectively. The preoperative diagnostic accuracy of MRI for colon cancer at T1, T2, T3, and T4 stages was 76.92%, 82.61%, 73.47%, and 86.67%, respectively, those of MSCT was 53.85%, 69.57%, 63.27%, and 40.00%, respectively, and those of MRI plus MSCT was 100.00%, 95.65%, 95.92%, and 86.67%, respectively. Consistency analysis yielded good consistency for the diagnosis of the T-staging of colon cancer (Kappa = 0.754, 0.731, 0.776). MSCT plus MRI yielded higher accuracy, specificity, and sensitivity in the detection of colon cancer versus the standalone MRI or MSCT, which demonstrated great potential in the early detection of colon cancer with a high clinical value.
Collapse
Affiliation(s)
- Jingni Zhang
- Department of Radiology, Affiliated Hospital of Jiangnan University, Wuxi 214062, Jiangsu Province, China
| | - Yu Bao
- Medical Imaging Center, Wuxi People's Hospital, Wuxi 214043, Jiangsu Province, China
| |
Collapse
|