1
|
Gruisen JAE, Schormans PMJ, Punt IM, Roth AK, van Kuijk SMJ, Poeze M, Hannemann PFW. Patient reported and functional outcome measures after surgical salvage procedures for posttraumatic radiocarpal osteoarthritis - a systematic review. BMC Musculoskelet Disord 2024; 25:453. [PMID: 38849773 PMCID: PMC11157883 DOI: 10.1186/s12891-024-07527-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/15/2024] [Accepted: 05/15/2024] [Indexed: 06/09/2024] Open
Abstract
BACKGROUND Posttraumatic wrist osteoarthritis is an irreversible and often progressive condition. Many surgical treatments, used in (daily) practice, aim to relieve symptoms like pain and restore function. The aim of this systematic review is to assess the patient reported and functional outcomes of the most common surgical interventions in patients with posttraumatic wrist osteoarthritis. This overview can help clinicians select the best treatment and manage patient's expectations. METHODS A literature search was performed in Pubmed, Embase and Cochrane for articles published between 1990 and November 2022 according to the PRISMA guidelines. The study protocol has been registered in the PROSPERO database (CRD42017080427). Studies that describe patient reported outcomes (pain and Disability of Arm, Shoulder and Hand (DASH) -score) and functional outcomes (range of motion (ROM) and grip strength) after surgical intervention with a minimal follow-up of 1 year were included. The identified surgical procedures included denervation, proximal row carpectomy, interpositional- and total arthroplasty, and midcarpal-, radiocarpal- and total arthrodesis. The pre-and postoperative outcomes were pooled and presented per salvage procedure. RESULTS Data from 50 studies was included. Pain score improved after all surgeries except denervation. Flexion/extension decreased after radiocarpal arthrodesis, did not show significant changes after proximal row carpectomy, and improved for all other surgeries. DASH score improved after arthroplasty, proximal row carpectomy and midcarpal arthrodesis. Grip strength improved after interposition arthroplasty and partial arthrodesis. CONCLUSION Evidence from this review did not support the indication for denervation in this particular patient population. In patients with SLAC/SNAC II, proximal row carpectomy might be favourable to a midcarpal arthrodesis solely based on better FE ROM of the radiocarpal joint after proximal row carpectomy. In terms of radiocarpal mobility, total wrist arthroplasty might be preferred to radiocarpal arthrodesis in patients with osteoarthritis after a distal radius fracture. More uniform measurements of outcomes would improve the understanding of the effect of surgical treatments of the posttraumatic osteoarthritic wrist.
Collapse
Affiliation(s)
- Jane A E Gruisen
- Department of Trauma and Orthopedic Surgery, Maastricht University Medical Centre, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
| | - Philip M J Schormans
- Department of Surgery, Amphia Hospital Breda, Molengracht 21, 4818 CK Breda, The Netherlands.
| | - Ilona M Punt
- Department of Trauma and Orthopedic Surgery, Maastricht University Medical Centre, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
| | - Alex K Roth
- Department of Trauma and Orthopedic Surgery, Maastricht University Medical Centre, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
| | - Sander M J van Kuijk
- Department of Klinische Epidemiologie en Medical Technology Assessment, Maastricht University, P.Debyelaan 25, Maastricht, 6229 HX, The Netherlands
| | - Martijn Poeze
- Department of Trauma and Orthopedic Surgery, Maastricht University Medical Centre, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
| | - Pascal F W Hannemann
- Department of Trauma and Orthopedic Surgery, Maastricht University Medical Centre, PO Box 5800, 6202 AZ, Maastricht, The Netherlands
| |
Collapse
|
2
|
Laudermilch D, Morales-Restrepo A, Bhogal S, Kaufmann RA. Parallel K-Wire Placement Leads to Fusion and Midcarpal Settling in Scaphoid Excision Four-Corner Fusion. Hand (N Y) 2023; 18:589-597. [PMID: 34933586 PMCID: PMC10233651 DOI: 10.1177/15589447211057302] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Scaphoid excision 4-corner fusion is a motion-sparing procedure in patients with advanced radioscaphoid arthritis. This study introduces an alternate technique for scaphoid excision 4-corner fusion using a parallel Kirschner wire (K-wire) construct across the midcarpal joints that leads to reliable fusion rates, and good patient outcomes. METHODS This is a single-surgeon, retrospective study of patients who underwent scaphoid excision 4-corner fusion, using a parallel K-wire construct across the midcarpal joints. Once fusion was achieved, K-wires were removed. Radiographic union rate, time to union, capitolunate angle, capitolunate coverage, and amount of midcarpal settling are measured. Patient-reported outcome measures and descriptive statistics are presented. RESULTS Sixty-five wrists were included in this study with a mean age of 50.1 years. One patient was lost to follow-up. All 64 wrists (100%) fused at an average of 2.6 months. The mean capitolunate angle was 7°, and capitolunate coverage was 99.2%. Fifty-two patients (81%) had adequate radiographs for measurement. Average midcarpal settling was 1.1 mm. Thirty-two patients (51%) were available for long-term follow-up at an average of 5.3 years (0.7-10.2 years), and participated in patient reported outcomes (PRO) surveys. The mean Quick Disabilities of the Arm, Shoulder, and Hand score was 16.6, and numeric pain rating scale score was 1.8. CONCLUSIONS Parallel K-wire placement across the midcarpal joints with scaphoid leads to a high rate of fusion with good patient outcomes long term. Midcarpal settling that occurs through dynamic compression around the K-wires may have contributed to bony fusion. This technique may provide an alternative approach to achieving reliable fusion across the midcarpal joints.
Collapse
|
3
|
Andronic O, Labèr R, Kriechling P, Karczewski D, Flury A, Nagy L, Schweizer A. Surgical fixation techniques in four-corner fusion of the wrist: a systematic review of 1103 cases. J Plast Surg Hand Surg 2023; 57:29-37. [PMID: 35522840 DOI: 10.1080/2000656x.2022.2070182] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Four-corner fusion (4CF) is a known treatment option for degenerative wrist conditions. Different techniques may be used and there is no general consensus on best implant. As such, it was the purpose of the current systematic review to compare fusion rates and outcomes depending on the fixation technique. METHODS The systematic review was registered in the international prospective register of systematic reviews (PROSPERO): CRD42020164301. It followed the PRISMA guidelines. Original articles were screened using the following databases: Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and Web of Science Core Collection. Studies reporting on outcome for 4CF surgery were included. Studies with a minimum Level IV of evidence were considered eligible. Quality assessment was performed using the Methodological Index for Non-Randomized Studies (MINORS) criteria. RESULTS A total of 29 studies met the inclusion criteria, for a total of 1103 wrists. The mean age was 41.8 years (range 19-83). Mean follow-up overall was 43.5 months (range 24-146 months). Reported fusion weighted rates were >90% and did not differ significantly between techniques. Reoperations due to different reasons occurred in 135 (12%) of all 1103. There was significant data heterogeneity regarding fusion rates (I2 = 70%). Inconsistency and heterogeneity in data reporting did not allow meta-analysis with direct data pooling and comparison of subgroups. CONCLUSIONS Satisfactory fusion rates (over 90%) can be achieved independent of the fixation technique used in 4-corner arthrodesis. Due to the high data heterogeneity and reporting inconsistency across studies, no statements regarding PROMs, ROM or grip strength can be made. LEVEL OF EVIDENCE Systematic Review of Level IV Studies.
Collapse
Affiliation(s)
- Octavian Andronic
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| | - Raffael Labèr
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| | - Philipp Kriechling
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| | - Daniel Karczewski
- Center for Musculoskeletal Surgery, Department of Orthopaedic Surgery, Charité - Universitaetsmedizin Berlin, Berlin, Germany
| | - Andreas Flury
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| | - Ladislav Nagy
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| | - Andreas Schweizer
- Department of Orthopaedics, Balgrist University Hospital, Zürich, Switzerland
| |
Collapse
|
4
|
Eder C, Scheller A, Schwab N, Krapohl BD. Four-corner arthrodesis of the wrist using Variable Angle Locking Compression Intercarpal Fusion Plate (VA LCP ICF Plate; Synthes ®): pre- and postoperative radiological analysis and clinical outcome in long-term evaluation. GMS INTERDISCIPLINARY PLASTIC AND RECONSTRUCTIVE SURGERY DGPW 2019; 8:Doc15. [PMID: 31815084 PMCID: PMC6883383 DOI: 10.3205/iprs000141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Long persisting scaphoid non-unions or scapholunate ligament ruptures can lead to carpal collapse. The resulting clinical symptoms are restrictions in the range of motion, pain, and loss of grip strength. The symptomatic treatment so far offers different options. In our study, the Variable Angle Locking Compression Intercarpal Fusion Plate (VA LCP ICF Plate) by Synthes® was used in 11 cases of advanced carpal collapse for a four-corner fusion of the wrist. The intra- and postoperative as well as follow-up results have been assessed and compared with those of current literature. The results of the Manchester-Modified Disability of the Shoulder, Arm and Hand Score (M²-Dash) showed an average of 41.5 points (MD=44/SD=16.62/MIN=21/MAX=65). One of the re-evaluated patients complained about pain at rest. One patient stated pain after mild strain; 4 patients complained pain after heavy burden (e.g. boxing, weight lifting). Measuring the range of motion, the operated hand showed a maximum in dorsal extension of 78.31% and in flexion of 57.89% compared to the contralateral, non-operated hand. In performance testing the fist clenching sign as well as pinch grip were complete and void of pain in 100%, whereas opposition (dig. man. I to V) was complete in five patients (83.33%), with moderate pain in one patient (16.67%) and a persisting gap of 0.2 cm in n=1 (16.67%). In comparison with the current literature regarding healing rates, complications, and follow-up results, we recommend the Synthes® VA LCP ICF Plate as a good surgical option in patients suffering from advanced carpal collapse.
Collapse
Affiliation(s)
- Christian Eder
- Centre for Musculoskeletal Surgery, Charité - Medical University, Campus Virchow Clinic, Berlin, Germany
| | - Ariane Scheller
- Centre for Musculoskeletal Surgery, Charité - Medical University, Campus Virchow Clinic, Berlin, Germany
| | | | | |
Collapse
|
5
|
Tielemans A, Van Innis F, Troussel S, Detrembleur C, Libouton X, Lequint T. Effect of four-corner fusion with locking plate without bone graft on functional recovery of the wrist: New treatment guidelines. HAND SURGERY & REHABILITATION 2017; 36:186-191. [DOI: 10.1016/j.hansur.2017.01.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/19/2016] [Revised: 01/07/2017] [Accepted: 01/12/2017] [Indexed: 12/14/2022]
|
6
|
Clinical and radiological outcomes of scaphoidectomy and 4-corner fusion in scapholunate advanced collapse at 5 and 10 years. Ann Plast Surg 2014; 71:166-9. [PMID: 23277107 DOI: 10.1097/sap.0b013e31824b3e1e] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
SUMMARY This retrospective study examined clinical and radiological outcomes of scaphoidectomy and 4-corner fusion in patients with a scapholunate advanced collapse (SLAC) at 5 and 10 years. PURPOSE Partial wrist arthrodesis is commonly performed to treat wrist arthritis because it provides pain relief without sacrificing complete wrist motion. The purposes of this retrospective study were to evaluate clinical and radiological outcomes after scaphoidectomy and 4-corner fusion after more than 10 years of follow-up and to compare the midterm and long-term results. METHODS Forty-two patients were enrolled. The following were evaluated annually: pain (visual analog scale); Disabilities of the Arm, Shoulder, and Hand score; range of motion; grip strength; and Modified Mayo Wrist score. Bony union and arthritic changes in the radiolunate joint were also evaluated radiologically. Midterm and long-term results were compared. RESULTS The mean (SD) follow-up period was 12.2 (1.43) years. Two patients were excluded from the study because of complications, so the final postoperative evaluation included 40 patients. Visual analog scale and Disabilities of the Arm, Shoulder, and Hand scores improved to a satisfactory level by 5 years after surgery and did not differ significantly between 5 and 10 years. Flexion, extension, and radial deviation were reduced after 5 years compared with preoperative measures, and no difference was found between 5 and 10 years. Ulnar deviation, pronation, and supination did not change significantly after surgery. Grip strength was significantly recovered from 29.7 (4.9) kg at 5 years after surgery to 32.1 (8.5) kg at 10 years. The Modified Mayo Wrist score improved significantly to 83.2 (4.1) at 5 years after surgery but did not differ significantly between 5 and 10 years. All cases showed radiological solid fusion, and the mean (SD) period of union was 9.34 (3.7) weeks. Further radiolunate arthritic change was verified in 2 patients, but Modified Mayo Wrist scores were fair. One patient experienced inexplicable pain; therefore, total wrist fusion was performed at 6 years after surgery. CONCLUSIONS This retrospective cohort study of patients followed up for more than 10 years showed that the midterm and long-term results of 4-corner fusion for stage III SLAC were satisfactory, and arthritic changes in the radiolunate joint were minimal.
Collapse
|
7
|
Xu YQ, Qi BC, Fan XY, Xu XS, Lu S, Ding J. Four-corner arthrodesis concentrator of nickel-titanium memory alloy for carpal collapse: a report on 18 cases. J Hand Surg Am 2012; 37:2246-51. [PMID: 23101519 DOI: 10.1016/j.jhsa.2012.07.040] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 07/27/2012] [Accepted: 07/31/2012] [Indexed: 02/02/2023]
Abstract
PURPOSE To evaluate the treatment of carpal collapse using a four-corner arthrodesis concentrator of nickel-titanium memory alloy. METHODS From August 2006 to August 2010, 18 patients with carpal collapse had scaphoid excision and four-corner (capitate, lunate, triquetrum, and hamate) arthrodesis using a nickel-titanium memory alloy four-corner arthrodesis concentrator. The mean follow-up time was 30 months (range, 12-48). Various wrist parameters, including grip strength, wrist motion, and degree of pain were recorded and compared before and after surgery. RESULTS The average fusion time was 2.3 months (range, 2-4). Neither nonunion nor wound infection was found in any of the patients. At one year follow-up, the grip strength had reached 80% of that of the healthy side, whereas the range of motion was greater than 50% of the contralateral side. After the surgery, the mean pain scores were improved. CONCLUSIONS Four-corner arthrodesis using a nickel-titanium memory alloy four-corner arthrodesis concentrator effectively treated carpal collapse and preserved most wrist function.
Collapse
Affiliation(s)
- Yong-qing Xu
- Department of Orthopedic Surgery, Kunming General Hospital, Kunming, China
| | | | | | | | | | | |
Collapse
|
8
|
Xu YQ, Qi BC, Zhu YL, Xu XS, Lu S, Li J, Ding J, Qin LM. Four-corner arthrodesis concentrator of Ni-Ti memory alloy for carpal collapse. Orthop Surg 2012; 2:266-71. [PMID: 22009961 DOI: 10.1111/j.1757-7861.2010.00098.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE To evaluate the treatment outcomes of a four-corner arthrodesis concentrator of Ni-Ti memory alloy for carpal collapse. METHODS From August 2006 to November 2009, 13 patients with carpal collapse underwent scaphoid excision and four-corner (capitate, lunate, triquetrum and hamate) arthrodesis using a four-corner arthrodesis concentrator of Ni-Ti memory alloy. The mean follow-up time was 26.5 months (range, 7-38 months). Various wrist parameters, including the grip strength, range of wrist movements and degree of pain (visual analogue scales) were recorded and compared before and after surgery. RESULTS The average fusion time was 2.3 months (range, 2-4 months). Neither non-union nor wound infection was found in any of the patients. By the sixth month postoperatively, the grip strength had reached an average of 32.49 ± 6.21 kg with a range of 22.3-39.7 kg, this being 80.8% of that found on the healthy side. The range of motion reached over 53.0% of that of the healthy side. Preoperatively and at 6 months postoperatively, the mean pain scores were (4.46 ± 1.27) and 1.31 ± 0.95, respectively, when resting (P < 0.05), and 7.00 ± 1.41 and 2.62 ± 1.26, respectively, when weight-bearing (P < 0.05). The mean value of the Krimmer wrist score was 79.2 (range, 64-84). The rate of excellent and fine results was 84.6% (11/13), being excellent in three cases, good in eight and fair in two. CONCLUSION Four-corner arthrodesis using a four-corner arthrodesis concentrator of Ni-Ti memory alloy is an effective method for treating carpal collapse and preserving most wrist function.
Collapse
Affiliation(s)
- Yong-Qing Xu
- Department of Orthopedic Surgery, Kunming General Hospital, Chengdu Military Region, Kunming, China.
| | | | | | | | | | | | | | | |
Collapse
|