1
|
Yang N, Nakagawa M, Nishiura A, Yamada M, Morikuni H, Honda Y, Matsumoto N. Identification of Senescent Cells in Peri-Implantitis and Prevention of Mini-Implant Loss Using Senolytics. Int J Mol Sci 2023; 24:ijms24032507. [PMID: 36768829 PMCID: PMC9916936 DOI: 10.3390/ijms24032507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Revised: 12/05/2022] [Accepted: 12/16/2022] [Indexed: 02/03/2023] Open
Abstract
Peri-implantitis is a disease that causes the detachment of orthodontic mini-implants. Recently, stress-induced senescent cells have been reported to be involved in various inflammatory diseases. Senescent cell-eliminating drugs, termed "senolytics", can improve the symptoms of such diseases. However, the relationship between peri-implantitis and senescent cells remains unclear. In this study, we evaluated the presence of senescent cells in a rat peri-implantitis model developed with a gum ring. The effect on bone resorption and implant loss was also investigated with and without senolytics (Dasatinib and Quercetin). The number of senescence markers (p19, p21, and p16) was found to increase, and implant detachment occurred in 24 days. After the administration of senolytics, the number of senescence markers decreased and implant detachment was inhibited. This study suggests that senescent cells aggravate peri-implantitis and senolytic administration latently reduces implant loss by inhibiting senescence-related mechanisms.
Collapse
Affiliation(s)
- Niuxin Yang
- Department of Orthodontics, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
| | - Masato Nakagawa
- Department of Oral Anatomy, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
- Correspondence: (M.N.); (Y.H.); Tel.: +81-90-1675-7895 (M.N.); +81-72-864-3013 (Y.H.)
| | - Aki Nishiura
- Department of Orthodontics, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
| | - Masahiro Yamada
- Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, 4-1 Seiryomachi, Sendai 980-8575, Japan
| | - Hidetoshi Morikuni
- Department of Orthodontics, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
| | - Yoshitomo Honda
- Department of Oral Anatomy, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
- Correspondence: (M.N.); (Y.H.); Tel.: +81-90-1675-7895 (M.N.); +81-72-864-3013 (Y.H.)
| | - Naoyuki Matsumoto
- Department of Orthodontics, Osaka Dental University, 8-1 Kuzuhahanazonocho, Hirakata 573-1121, Japan
| |
Collapse
|
2
|
Sfondrini MF, Gandini P, Alcozer R, Vallittu PK, Scribante A. Failure load and stress analysis of orthodontic miniscrews with different transmucosal collar diameter. J Mech Behav Biomed Mater 2018; 87:132-137. [PMID: 30059839 DOI: 10.1016/j.jmbbm.2018.07.032] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 07/13/2018] [Accepted: 07/23/2018] [Indexed: 02/07/2023]
Abstract
Miniscrews have been introduced in orthodontics as temporary anchorage devices (TADs), in order to move the correct teeth and avoid other elements to slide toward a wrong direction. Moreover the ease of use of TADs encouraged clinicians to use miniscrews also for non-conventional purposes, as fixation in mandibular fracture, mini-implant supported temporary pontics, miniscrew-assisted rapid palatal expanders and distalizers. These applications develop higher forces, so TAD fracture can be an unwanted complication. Some authors analyzed torsional loads but no studies measured forces required to bend the screws and ultimate flexural strength. Accordingly, in the present report, Ti-6Al-4V TADs were mechanically evaluated. Seven different diameters of screws were tested: 1.3 mm (Aarhus Screw, Medicon), 1.5 mm (Spider Screw, HDC), 1.6 mm (Aarhus Screw, Medicon), 1.7 mm (Ortho Easy, Forestadent), 1.8 mm (Ortho Implant, 3 M), 1.9 mm (Spider Screw, HDC) and 2.0 mm (Storm, Kristal). The forces to bend the titanium TADs were measured at 0.1 mm, 0.2 mm magnitude of deflections and at maximum load (as peak before screw fracture) in air with a universal testing machine. Statistical analyses were performed. Both at 0.1 mm and at 0.2 mm deflections and at maximum load, the significantly highest forces were reported with 1.7, 1.8, 1.9, and 2.0 mm TADs. The lowest values were reported with 1.6, 1.5, and 1.3 mm mini-implants. No significant differences were reported between 1.6 mm and 1.7 mm screws. It was found that load values in N versus stress in MPa were not fully comparable when screws with small and larger diameter were compared. Therefore, when placing a miniscrew for applications that need maximum shear bending resistance, these results would be considered in order to reduce risk of unwanted fracture.
Collapse
Affiliation(s)
- Maria Francesca Sfondrini
- Unit of Orthodontics and Paediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Paola Gandini
- Unit of Orthodontics and Paediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Roberto Alcozer
- Unit of Orthodontics and Paediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Piazzale Golgi 2, 27100 Pavia, Italy
| | - Pekka K Vallittu
- Department of Biomaterial Science and Turku Clinical Biomaterials Centre - TCBC, Institute of Dentistry, University of Turku, Turku, Finland; City of Turku, Welfare Division, Turku, Finland
| | - Andrea Scribante
- Unit of Orthodontics and Paediatric Dentistry - Section of Dentistry - Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, Piazzale Golgi 2, 27100 Pavia, Italy.
| |
Collapse
|
3
|
Scribante A, Montasser MA, Radwan ES, Bernardinelli L, Alcozer R, Gandini P, Sfondrini MF. Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs). MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1138. [PMID: 29976856 PMCID: PMC6073155 DOI: 10.3390/ma11071138] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/04/2018] [Revised: 06/25/2018] [Accepted: 07/03/2018] [Indexed: 11/30/2022]
Abstract
Temporary anchorage devices (TADs) have been introduced into orthodontic clinical practice in order to allow tooth movements while avoiding strain on adjacent teeth. Miniscrews are available in the market with different diameters and materials. Accordingly, the purpose of the present report was to measure and compare the forces to bend and fracture different mini implants. Ti-6Al-4V titanium and stainless steel TADs of different manufacturers (Spider ScrewHDC; Mini Implants⁻Leone; Benefit⁻Orteam; Storm⁻Kristal) were evaluated. Two different diameters (1.5 mm and 2.0 mm) were tested. The sample included 10 unused specimens for each group, blocked in an Instron Universal Testing Machine, and a shear load was applied at the neck of the miniscrew. The force to bend the miniscrew was measured at 0.1 mm and 0.2 mm deflections. Also, the maximum force before screw fracture was recorded. Data were submitted for statistical analysis. Results showed significantly higher forces for 2.0 mm than 1.5 mm screws, both at 0.1 mm and 0.2 mm deflections and at maximum load. Moreover, no significant differences were reported between titanium and stainless steel miniscrews of equal diameters.
Collapse
Affiliation(s)
- Andrea Scribante
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Mona A Montasser
- Orthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura 35511, Egypt.
| | - Eman Saad Radwan
- Orthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura 35511, Egypt.
| | - Luisa Bernardinelli
- Section of Statistics, Department of Brain and Behavioural Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Roberto Alcozer
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Paola Gandini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Maria Francesca Sfondrini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| |
Collapse
|
4
|
Scribante A, Montasser MA, Radwan ES, Bernardinelli L, Alcozer R, Gandini P, Sfondrini MF. Reliability of Orthodontic Miniscrews: Bending and Maximum Load of Different Ti-6Al-4V Titanium and Stainless Steel Temporary Anchorage Devices (TADs). MATERIALS (BASEL, SWITZERLAND) 2018. [PMID: 29976856 DOI: 10.3390/ecms2018-05219] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Temporary anchorage devices (TADs) have been introduced into orthodontic clinical practice in order to allow tooth movements while avoiding strain on adjacent teeth. Miniscrews are available in the market with different diameters and materials. Accordingly, the purpose of the present report was to measure and compare the forces to bend and fracture different mini implants. Ti-6Al-4V titanium and stainless steel TADs of different manufacturers (Spider ScrewHDC; Mini Implants⁻Leone; Benefit⁻Orteam; Storm⁻Kristal) were evaluated. Two different diameters (1.5 mm and 2.0 mm) were tested. The sample included 10 unused specimens for each group, blocked in an Instron Universal Testing Machine, and a shear load was applied at the neck of the miniscrew. The force to bend the miniscrew was measured at 0.1 mm and 0.2 mm deflections. Also, the maximum force before screw fracture was recorded. Data were submitted for statistical analysis. Results showed significantly higher forces for 2.0 mm than 1.5 mm screws, both at 0.1 mm and 0.2 mm deflections and at maximum load. Moreover, no significant differences were reported between titanium and stainless steel miniscrews of equal diameters.
Collapse
Affiliation(s)
- Andrea Scribante
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Mona A Montasser
- Orthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura 35511, Egypt.
| | - Eman Saad Radwan
- Orthodontic Department, Faculty of Dentistry, Mansoura University, Mansoura 35511, Egypt.
| | - Luisa Bernardinelli
- Section of Statistics, Department of Brain and Behavioural Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Roberto Alcozer
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Paola Gandini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| | - Maria Francesca Sfondrini
- Unit of Orthodontics and Paediatric Dentistry, Section of Dentistry, Department of Clinical, Surgical, Diagnostic and Paediatric Sciences, University of Pavia, 27100 Pavia, Italy.
| |
Collapse
|