1
|
Wang J, Greuter MJ, Zheng S, van Veldhuizen DW, Vermeulen KM, Wang Y, Lu W, de Bock GH. Assessment of the Benefits and Cost-Effectiveness of Population-Based Breast Cancer Screening in Urban China: A Model-Based Analysis. Int J Health Policy Manag 2022; 11:1658-1667. [PMID: 34273933 PMCID: PMC9808213 DOI: 10.34172/ijhpm.2021.62] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2020] [Accepted: 05/30/2021] [Indexed: 01/12/2023] Open
Abstract
BACKGROUND To decrease the burden of breast cancer (BC), the Chinese government recently introduced biennial mammography screening for women aged 45-70 years. In this study, we assess the effectiveness and cost-effectiveness of implementing this programme in urban China using a micro-simulation model. METHODS The 'Simulation Model on radiation Risk and breast cancer Screening' (SiMRiSc) was applied, with parameters updated based on available data for the Chinese population. The base scenario was biennial mammography screening for women aged 45-70 years, and this was compared to a reference population with no screening. Seven alternative scenarios were then simulated by varying the screening intervals and participant ages. This analysis was conducted from a societal perspective. The discounted incremental cost-effectiveness ratio (ICER) was compared to a threshold of triple the gross domestic product (GDP) per life years gained (LYG), which was 30 785 USD/LYG. Univariate sensitivity analyses were conducted to evaluate model robustness. In addition, a budget impact analysis was performed by comparing biennial screening with no screening at a time horizon of 10 years. RESULTS Compared with no screening, the base scenario was cost-effective in urban China, giving a discounted average cost-effectiveness ratio (ACER) of 17 309 USD/LYG. The model was most sensitive to the cost of mammography per screen, followed by mean size of self-detected tumours, mammographic breast density and the cumulative lifetime risk of BC. The efficient frontier showed that at a threshold of 30 785 USD/LYG, the base scenario was the optimal scenario with a discounted ICER of 25 261 USD/LYG. Over 10 years, screening would incur a net cost of almost 38.1 million USD for a city with 1 million citizens. CONCLUSION Compared to no screening, biennial mammography screening for women aged from 45-70 is cost-effective in urban China.
Collapse
Affiliation(s)
- Jing Wang
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Marcel J.W. Greuter
- Department of Radiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Robotics and Mechatronics (RaM) Group, Faculty of Electrical Engineering Mathematics and Computer Science, Technical Medical Centre, University of Twente, Enschede, The Netherlands
| | - Senshuang Zheng
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Daniëlle W.A. van Veldhuizen
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Karin M. Vermeulen
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Yuan Wang
- Department of Epidemiology and Health Statistics, School of Public Health, Tianjin Medical University, Tianjin, China
- Collaborative Innovation Center of Chronic Disease Prevention and Control, School of Public Health, Tianjin Medical University, Tianjin, China
| | - Wenli Lu
- Department of Epidemiology and Health Statistics, School of Public Health, Tianjin Medical University, Tianjin, China
- Collaborative Innovation Center of Chronic Disease Prevention and Control, School of Public Health, Tianjin Medical University, Tianjin, China
| | - Geertruida H. de Bock
- Department of Epidemiology, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
2
|
Hajipour Khire Masjidi B, Bahmani S, Sharifi F, Peivandi M, Khosravani M, Hussein Mohammed A. CT-ML: Diagnosis of Breast Cancer Based on Ultrasound Images and Time-Dependent Feature Extraction Methods Using Contourlet Transformation and Machine Learning. COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE 2022; 2022:1493847. [PMID: 35655521 PMCID: PMC9155970 DOI: 10.1155/2022/1493847] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/04/2021] [Revised: 02/02/2022] [Accepted: 02/28/2022] [Indexed: 12/15/2022]
Abstract
Breast diseases are a group of diseases that appear in different forms. An entire group of these diseases is breast cancer. This disease is one of the most important and common diseases in women. A machine learning system has been trained to identify specific patterns using an algorithm in a machine learning system to diagnose breast cancer. Therefore, designing a feature extraction method is essential to decrease the computation time. In this article, a two-dimensional contourlet is utilized as the input image based on the Breast Cancer Ultrasound Dataset. The sub-banded contourlet coefficients are modeled using the time-dependent model. The features of the time-dependent model are considered the leading property vector. The extracted features are applied separately to determine breast cancer classes based on classification methods. The classification is performed for the diagnosis of tumor types. We used the time-dependent approach to feature contourlet sub-bands from three groups of benign, malignant, and health control test samples. The final feature of 1200 ultrasound images used in three categories is trained based on k-nearest neighbor, support vector machine, decision tree, random forest, and linear discrimination analysis approaches, and the results are recorded. The decision tree results show that the method's sensitivity is 87.8%, 92.0%, and 87.0% for normal, benign, and malignant, respectively. The presented feature extraction method is compatible with the decision tree approach for this problem. Based on the results, the decision tree architecture with the highest accuracy is the more accurate and compatible method for diagnosing breast cancer using ultrasound images.
Collapse
Affiliation(s)
| | - Soufia Bahmani
- Department of Computer Engineering and Information Technology, Amirkabir University of Technology, Tehran 15875-4413, Iran
| | - Fatemeh Sharifi
- Department of Electrical Engineering, University of Applied Science and Technology, Bushehr, Iran
| | - Mohammad Peivandi
- Hochschule für Technik und Wirtschaft Berlin (HTW Berlin), Berlin, Germany
| | - Mohammad Khosravani
- Department of Electrical & Computer Engineering, Arak University of Technology, Arak, Iran
| | - Adil Hussein Mohammed
- Department of Communication and Computer Engineering, Faculty of Engineering, Cihan University-Erbil, Kurdistan Region, Iraq
| |
Collapse
|
3
|
Berg WA. BI-RADS 3 on Screening Breast Ultrasound: What Is It and What Is the Appropriate Management? JOURNAL OF BREAST IMAGING 2021; 3:527-538. [PMID: 34545351 PMCID: PMC8445238 DOI: 10.1093/jbi/wbab060] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2021] [Indexed: 12/24/2022]
Abstract
US is widely used in breast imaging for diagnostic purposes and is also used increasingly for supplemental screening in women with dense breasts. US frequently depicts masses that are occult on mammography, even after tomosynthesis, and the vast majority of such masses are benign. Many masses seen only on screening US are easily recognized as benign simple cysts. Probably benign, BI-RADS 3, or low suspicion, BI-RADS 4A masses are also common and often prompt short-interval follow-up or biopsy, respectively, yet the vast majority of these are benign. This review details appropriate characterization, classification, and new approaches to the management of probably benign masses seen on screening US that can reduce false positives and, thereby, reduce costs and patient anxiety.
Collapse
Affiliation(s)
- Wendie A Berg
- University of Pittsburgh School of Medicine, Department of Radiology, Magee-Womens Hospital of UPMC, Pittsburgh, PA, USA
| |
Collapse
|
4
|
Lee SE, Kim HY, Yoon JH, Kim EK, Kim JY, Kim MJ, Kim GR, Park YV, Moon HJ. Chronological Trends of Breast Ductal Carcinoma In Situ: Clinical, Radiologic, and Pathologic Perspectives. Ann Surg Oncol 2021; 28:8699-8709. [PMID: 34196861 DOI: 10.1245/s10434-021-10378-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 06/11/2021] [Indexed: 12/11/2022]
Abstract
BACKGROUND Because no prior studies have evaluated the chronological trends of ductal carcinoma in situ (DCIS) despite the increasing number of surgeries performed for DCIS, this study analyzed how the clinical, radiologic, and pathologic characteristics of DCIS changed during a 10-year period. METHODS Of 7123 patients who underwent primary breast cancer surgery at a single institution from 2006 to 2015, 792 patients with pure DCIS were included in this study. The chronological trends of age, symptoms, method for detecting either mammography or ultrasonography, tumor size, nuclear grade, comedonecrosis, and molecular markers were calculated using Poisson regression for all patients and asymptomatic patients. RESULTS During 10 years, DCIS surgery rates significantly increased (p < 0.001). Despite the high percentage of DCIS detected on mammography, the detection rate for DCIS by mammography significantly decreased (97.3% in 2006 to 67.6% in 2015; p = 0.025), whereas the detection rate by ultrasound significantly increased (2.7% to 31.0%; p < 0.001). Conservation surgery rates (odds ratio [OR], 1.058), low-to-intermediate nuclear grade rates (OR, 1.069), and the absence of comedonecrosis (OR, 1.104) significantly increased over time (all p < 0.05). Estrogen receptor (ER) negativity (OR, 0.935) and human epidermal growth factor receptor 2 (HER2) positivity rates (OR, 0.953) significantly decreased (all p < 0.05). The same trends were observed for the 613 asymptomatic patients. CONCLUSION The rate of DCIS detected on ultrasound only significantly increased during 10 years. Low-to-intermediate nuclear grade rates significantly increased, whereas ER negativity and HER2 positivity rates significantly decreased during the same period. These findings suggest that DCIS detected on screening ultrasound is less aggressive than DCIS detected on mammography.
Collapse
Affiliation(s)
- Si Eun Lee
- Department of Radiology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea
| | - Ha Yan Kim
- Biostatistics Collaboration Unit, Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, Korea
| | - Jung Hyun Yoon
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Eun-Kyung Kim
- Department of Radiology, Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Korea
| | - Jee Ye Kim
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Ga Ram Kim
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Youngjean Vivian Park
- Department of Radiology, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, Korea.
| |
Collapse
|
5
|
Huh S, Suh HJ, Kim EK, Kim MJ, Yoon JH, Park VY, Moon HJ. Follow-Up Intervals for Breast Imaging Reporting and Data System Category 3 Lesions on Screening Ultrasound in Screening and Tertiary Referral Centers. Korean J Radiol 2020; 21:1027-1035. [PMID: 32691538 PMCID: PMC7371624 DOI: 10.3348/kjr.2019.0747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 11/30/2022] Open
Abstract
Objective To assess the appropriate follow-up interval, and rate and timepoint of cancer detection in women with Breast Imaging Reporting and Data System (BI-RADS) 3 lesions on screening ultrasonography (US) according to the type of institution. Materials and Methods A total of 1451 asymptomatic women who had negative or benign findings on screening mammogram, BI-RADS 3 assessment on screening US, and at least 6 months of follow-up were included. The median follow-up interval was 30.8 months (range, 6.8–52.9 months). The cancer detection rate, cancer detection timepoint, risk factors, and clinicopathological characteristics were compared between the screening and tertiary centers. Nominal variables were compared using the chi-square or Fisher's exact test and continuous variables were compared using the independent t test or Mann-Whitney U test. Results In 1451 women, 19 cancers (1.3%) were detected; two (0.1%) were diagnosed at 6 months and 17 (1.2%) were diagnosed after 12.3 months. The malignancy rates were both 1.3% in the screening (9 of 699) and tertiary (10 of 752) centers. In the screening center, all nine cancers were invasive cancers and diagnosed after 12.3 months. In the tertiary center, two were ductal carcinomas in situ and eight were invasive cancers. Two of the invasive cancers were diagnosed at 6 months and the remaining eight cancers newly developed after 13.1 months. Conclusion One-year follow-up rather than 6-month follow-up may be suitable for BI-RADS 3 lesions on screening US found in screening centers. However, more caution is needed regarding similar findings in tertiary centers where 6-month follow-up may be more appropriate.
Collapse
Affiliation(s)
- Sun Huh
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Suh
- Department of Radiology, Severance Check-Up, Seoul, Korea
| | - Eun Kyung Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Jung Hyun Yoon
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Vivian Youngjean Park
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
| |
Collapse
|
6
|
Won SY, Park HS, Kim EK, Kim SI, Moon HJ, Yoon JH, Park VY, Park S, Kim MJ, Cho YU, Park BW. Survival Rates of Breast Cancer Patients Aged 40 to 49 Years according to Detection Modality in Korea: Screening Ultrasound versus Mammography. Korean J Radiol 2020; 22:159-167. [PMID: 32901456 PMCID: PMC7817635 DOI: 10.3348/kjr.2019.0588] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 04/29/2020] [Accepted: 05/12/2020] [Indexed: 12/31/2022] Open
Abstract
Objective The aim of this study was to compare the survival rates of Korean females aged 40 to 49 years with breast cancer detected by supplemental screening ultrasound (US) or screening mammography alone. Materials and Methods This single-institution retrospective study included 240 patients with breast cancer (mean age, 45.1 ± 2.8 years) detected by US or mammography who had undergone breast surgery between 2003 and 2008. Medical records were reviewed for clinicopathologic characteristics and detection methods. Disease-free survival (DFS) and overall survival (OS) were compared between patients with breast cancer in the US and mammography groups using the log-rank test. Multivariable cox regression analysis was used to identify independent variables associated with DFS and OS. Results Among the 240 cases of breast cancer, 43 were detected by supplemental screening US and 197 by screening mammography (mean follow-up: 7.4 years, 93.3% with dense breasts). There were 19 recurrences and 16 deaths, all occurring in the mammography group. While the US group did not differ from the mammography group in tumor stage, the patients in this group were more likely to undergo breast-conserving surgery and radiation therapy than the mammography group. The US group also showed better DFS (p = 0.016); however, OS did not differ between the two groups (p = 0.058). In the multivariable analysis, the US group showed a lower risk of recurrence (hazard ratio, 0.097; 95% confidence interval, 0.001–0.705) compared to the mammography group. Conclusion Our study found that Korean females aged 40–49 years with US-detected breast cancer showed better DFS than those with mammography-detected breast cancer. However, there were no statistically significant differences in OS.
Collapse
Affiliation(s)
- So Yeon Won
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Hyung Seok Park
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Eun Kyung Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Seung Il Kim
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Hee Jung Moon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Jung Hyun Yoon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Vivian Youngjean Park
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Seho Park
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Min Jung Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea.
| | - Young Up Cho
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| | - Byeong Woo Park
- Department of Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
7
|
Yang L, Wang S, Zhang L, Sheng C, Song F, Wang P, Huang Y. Performance of ultrasonography screening for breast cancer: a systematic review and meta-analysis. BMC Cancer 2020; 20:499. [PMID: 32487106 PMCID: PMC7268243 DOI: 10.1186/s12885-020-06992-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Accepted: 05/21/2020] [Indexed: 01/04/2023] Open
Abstract
Background To investigate the performance of primary ultrasound (P-US) screening for breast cancer, and that of supplemental ultrasound (S-US) screening for breast cancer after negative mammography (MAM). Methods Electronic databases (PubMed, Scopus, Web of Science, and Embase) were systematically searched to identify relevant studies published between January 2003 and May 2018. Only high-quality or fair-quality studies reporting any of the following performance values for P-US or S-US screening were included: sensitivity, specificity, cancer detected rate (CDR), recall rate (RR), biopsy rate (BR), proportion of invasive cancers among screening-detected cancers (ProIC), and proportion of node-negative cancers among screening-detected invasive cancers (ProNNIC). Results Twenty-three studies were included, including 12 studies in which S-US screening was used after negative MAM and 11 joint screening studies in which both primary MAM (P-MAM) and P-US were used. Meta-analyses revealed that S-US screening could detect 96% [95% confidential intervals (CIs): 82 to 99%] of occult breast cancers missed by MAM and identify 93% (95% CIs: 89 to 96%) of healthy women, with a CDR of 3.0/1000 (95% CIs: 1.8/1000 to 4.6/1000), RR of 8.8% (95% CIs: 5.0 to 13.4%), BR of 3.9% (95% CIs: 2.7 to 5.4%), ProIC of 73.9% (95% CIs: 49.0 to 93.7%), and ProNNIC of 70.9% (95% CIs: 46.0 to 91.6%). Compared with P-MAM screening, P-US screening led to the recall of significantly more women with positive screening results [1.5% (95% CIs:0.6 to 2.3%), P = 0.001] and detected significantly more invasive cancers [16.3% (95% CIs: 10.6 to 22.1%), P < 0.001]. However, there were no significant differences for other performance measures between the two screening methods, including sensitivity, specificity, CDR, BR, and ProNNIC. Conclusions Current evidence suggests that S-US screening could detect occult breast cancers missed by MAM. P-US screening has shown to be comparable to P-MAM screening in women with dense breasts in terms of sensitivity, specificity, cancer detection rate, and biopsy rate, but with higher recall rates and higher detection rates for invasive cancers.
Collapse
Affiliation(s)
- Lei Yang
- Key laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Beijing Office for Cancer Prevention and Control, Peking University Cancer Hospital & Institute, Beijing, 100142, China
| | - Shengfeng Wang
- Department of Epidemiology & Biostatistics, School of Public Health, Peking University, Beijing, 100191, China
| | - Liwen Zhang
- Department of Epidemiology and Biostatistics, Key Laboratory of Cancer Prevention and Therapy (Tianjin), Key Laboratory of Breast Cancer Prevention and Therapy (National Ministry of Education), Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China.,National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China
| | - Chao Sheng
- Department of Epidemiology and Biostatistics, Key Laboratory of Cancer Prevention and Therapy (Tianjin), Key Laboratory of Breast Cancer Prevention and Therapy (National Ministry of Education), Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China.,National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China
| | - Fengju Song
- Department of Epidemiology and Biostatistics, Key Laboratory of Cancer Prevention and Therapy (Tianjin), Key Laboratory of Breast Cancer Prevention and Therapy (National Ministry of Education), Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China.,National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China
| | - Ping Wang
- Department of Epidemiology and Biostatistics, Key Laboratory of Cancer Prevention and Therapy (Tianjin), Key Laboratory of Breast Cancer Prevention and Therapy (National Ministry of Education), Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China.,National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China
| | - Yubei Huang
- Department of Epidemiology and Biostatistics, Key Laboratory of Cancer Prevention and Therapy (Tianjin), Key Laboratory of Breast Cancer Prevention and Therapy (National Ministry of Education), Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China. .,National Clinical Research Center for Cancer, Tianjin Medical University Cancer Institute and Hospital, Tianjin, 300060, China.
| |
Collapse
|
8
|
Sood R, Rositch AF, Shakoor D, Ambinder E, Pool KL, Pollack E, Mollura DJ, Mullen LA, Harvey SC. Ultrasound for Breast Cancer Detection Globally: A Systematic Review and Meta-Analysis. J Glob Oncol 2020; 5:1-17. [PMID: 31454282 PMCID: PMC6733207 DOI: 10.1200/jgo.19.00127] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
PURPOSE Mammography is not always available or feasible. The purpose of this systematic review and meta-analysis is to assess the diagnostic performance of ultrasound as a primary tool for early detection of breast cancer. MATERIALS AND METHODS For this systematic review and meta-analysis, we comprehensively searched PubMed and SCOPUS to identify articles from January 2000 to December 2018 that included data on the performance of ultrasound for detection of breast cancer. Studies evaluating portable, handheld ultrasound as an independent detection modality for breast cancer were included. Quality assessment and bias analysis were performed with the Quality Assessment of Diagnostic Accuracy Studies-2 tool. Sensitivity analyses and meta-regression were used to explore heterogeneity. The study protocol has been registered with the international prospective register of systematic reviews (PROSPERO identifier: CRD42019127752). RESULTS Of the 526 identified studies, 26 were eligible for inclusion. Ultrasound had an overall pooled sensitivity and specificity of 80.1% (95% CI, 72.2% to 86.3%) and 88.4% (95% CI, 79.8% to 93.6%), respectively. When only low- and middle-income country data were considered, ultrasound maintained a diagnostic sensitivity of 89.2% and specificity of 99.1%. Meta-analysis of the included studies revealed heterogeneity. The high sensitivity of ultrasound for the detection of breast cancer was not statistically significantly different in subgroup analyses on the basis of mean age, risk, symptoms, study design, bias level, and study setting. CONCLUSION Given the increasing burden of breast cancer and infeasibility of mammography in certain settings, we believe these results support the potential use of ultrasound as an effective primary detection tool for breast cancer, which may be beneficial in low-resource settings where mammography is unavailable.
Collapse
Affiliation(s)
- Rupali Sood
- Johns Hopkins Medicine, Baltimore, MD.,RAD-AID International, Chevy Chase, MD
| | - Anne F Rositch
- The Johns Hopkins Bloomberg School of Public Health, Baltimore, MD
| | | | | | - Kara-Lee Pool
- RAD-AID International, Chevy Chase, MD.,University of California, Los Angeles, CA
| | - Erica Pollack
- RAD-AID International, Chevy Chase, MD.,Denver Health Medical Center, Denver, CO
| | | | | | - Susan C Harvey
- Johns Hopkins Medicine, Baltimore, MD.,RAD-AID International, Chevy Chase, MD
| |
Collapse
|
9
|
Huang Y, Tong Z, Chen K, Wang Y, Liu P, Gu L, Liu J, Yu J, Song F, Zhao W, Shi Y, Li H, Xiao H, Hao X. Interpretation of breast cancer screening guideline for Chinese women. Cancer Biol Med 2019; 16:825-835. [PMID: 31908899 PMCID: PMC6936244 DOI: 10.20892/j.issn.2095-3941.2019.0322] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/24/2019] [Accepted: 12/26/2019] [Indexed: 12/19/2022] Open
Abstract
Breast cancer is the most common malignant tumor in Chinese women. Early screening is the best way to improve the rates of early diagnosis and survival of breast cancer patients. The peak onset age for breast cancer in Chinese women is considerably younger than those in European and American women. It is imperative to develop breast cancer screening guideline that is suitable for Chinese women. By summarizing the current evidence on breast cancer screening in Chinese women, and referring to the latest guidelines and consensus on breast cancer screening in Europe, the United States, and East Asia, the China Anti-Cancer Association and National Clinical Research Center for Cancer (Tianjin Medical University Cancer Institute and Hospital) have formulated population-based guideline for breast cancer screening in Chinese women. The guideline provides recommendations on breast cancer screening for Chinese women at average or high risk of breast cancer according to the following three aspects: age of screening, screening methods, and screening interval. This article provides more detailed information to support the recommendations in this guideline and to provide more direction for current breast cancer screening practices in China.
Collapse
Affiliation(s)
| | | | - Kexin Chen
- Department of Epidemiology and Statistics
| | - Ying Wang
- Department of Epidemiology and Statistics
- China Anti-Cancer Association, Tianjin 300060, China
| | | | - Lin Gu
- The 2 Surgery Department of Breast Oncology
| | | | - Jinpu Yu
- Cancer Molecular Diagnostics Core
| | | | - Wenhua Zhao
- Department of Epidemiology and Statistics
- China Anti-Cancer Association, Tianjin 300060, China
| | - Yehui Shi
- Medicine Department of Breast Oncology
| | - Hui Li
- Department of Gastrointestinal Cancer Biology
| | - Huaiyuan Xiao
- Department of Research and Education, Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Tianjin 300060, China
| | - Xishan Hao
- Department of Epidemiology and Statistics
- China Anti-Cancer Association, Tianjin 300060, China
| |
Collapse
|
10
|
Sabek EAS, Salem HT. Technical Factors Affecting Ultrasound Breast Tumor Size as Correlated with Pathological Type. MEDICINA (KAUNAS, LITHUANIA) 2019; 55:E713. [PMID: 31731397 PMCID: PMC6915355 DOI: 10.3390/medicina55110713] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 10/11/2019] [Accepted: 10/16/2019] [Indexed: 11/17/2022]
Abstract
Background and Objectives: Accurate breast tumor sizing is very important in treatment planning; as a result, ultrasound (US) plays an important role in diagnosing breast masses, due to its non-magnified image and its availability. The continuous change in the disease pathogenesis of breast cancer and tremendous advances in US imaging technology require the continuous evaluation of this imaging modality. In this study, our aim was to determine the accuracy of US in measuring the size of breast mass, and if there is an influence of the different pathological types on this accuracy. Materials and Methods: This study contained 66 specimens of breast masses that underwent surgical excision and pathological examination of the resected masses; the mean difference between the size taken by US and the size taken by pathology was calculated to the patients as a whole and for each tumor type in this study. Results: The result was that US underestimates the size of the tumor by 0.5 cm for all pathological types, and the US size is in agreement with the pathology size. Conclusions: US is an accurate method in measuring breast lesions with a degree of underestimation that may be related to many factors such as the tumor type, size, and margins. Complementary MRI is recommended in case of ILC and architectural distortion.
Collapse
Affiliation(s)
- Eman Ahmed Shawky Sabek
- Health Radiation Research Department, National Center of Radiation Research and Technology, Atomic Energy Authority, 3 Ahmed El-zomor street, Nasr City, P.O. BOX 9621, Cairo 11765, Egypt;
| | | |
Collapse
|
11
|
Nowikiewicz T, Nowak A, Wiśniewska M, Wiśniewski M, Nowikiewicz M, Zegarski W. Analysis of the causes of false negative and false positive results of preoperative axillary ultrasound in patients with early breast cancer - a single-centre study. Contemp Oncol (Pozn) 2018; 22:247-251. [PMID: 30783389 PMCID: PMC6377422 DOI: 10.5114/wo.2018.82644] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Accepted: 11/30/2018] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION Properly planned and performed diagnostic tests allow the optimal treatment option to be chosen for the patient. They also allow qualification for the correct surgical procedure. AIM OF THE STUDY In this study we evaluated the clinical value of preoperative ultrasound scan (USS) testing performed during primary disease staging in patients with early breast cancer qualified to sentinel lymph node biopsy (SLNB). MATERIAL AND METHODS The group of breast cancer patients who underwent SLNB from March 2012 to May 2013. As well as the standard procedure of the preoperative diagnostics model, in each patient the USS of axillary lymph nodes was performed additionally. The results were compared with the data from postoperative pathological reports. We attempted to define the factors influencing the possibility of obtaining false positive and false negative USS results. RESULTS The analysis comprised 172 patients. In 14.4% of cases with normal USS result the pathological result was different from the expected one (pN1). In 42.3% of patients with suspicious axillary lymph nodes the result of the pathological report was positive. The sensitivity of the USS testing was 89.3%, and the specificity was 34.4%, PPV - 85.6%, NPV - 42.3%. CONCLUSIONS Ultrasonographic assessment of axillary lymph nodes in breast cancer patients qualified for SLNB is a test with high sensitivity and high predictive value of the positive test result. The possibility of a result contrary to the actual nodal status may result primarily from the technical limitations of USS testing.
Collapse
Affiliation(s)
- Tomasz Nowikiewicz
- Chair and Department of Surgical Oncology, Ludwik Rydygier’s Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
- Department of Breast Cancer and Reconstructive Surgery, Prof. Franciszek Łukaszczyk Oncology Centre, Bydgoszcz, Poland
| | - Adam Nowak
- Diagnostic Imaging and Interventional Radiology Unit, Prof. Franciszek Łukaszczyk Oncology Centre, Bydgoszcz, Poland
| | - Magdalena Wiśniewska
- Department of Oncology and Brachytherapy, Ludwik Rydygier’s Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
- Chemotherapy Department, Prof. Franciszek Łukaszczyk Oncology Centre, Bydgoszcz, Poland
| | - Michał Wiśniewski
- Outpatient Chemotherapy Department, Prof. Franciszek Łukaszczyk Oncology Centre, Bydgoszcz, Poland
| | - Magdalena Nowikiewicz
- Student Scientific Society, Chair and Department of Surgical Oncology, Ludwik Rydygier’s Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
| | - Wojciech Zegarski
- Chair and Department of Surgical Oncology, Ludwik Rydygier’s Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University in Torun, Bydgoszcz, Poland
- Department of Breast Cancer and Reconstructive Surgery, Prof. Franciszek Łukaszczyk Oncology Centre, Bydgoszcz, Poland
| |
Collapse
|
12
|
Kim MJ. Medical auditing of whole-breast screening ultrasonography. Ultrasonography 2017; 36:198-203. [PMID: 28322034 PMCID: PMC5494866 DOI: 10.14366/usg.17005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 02/15/2017] [Accepted: 02/16/2017] [Indexed: 11/07/2022] Open
Abstract
Since breast ultrasonography (US) has been used as an adjunctive screening modality in women with dense breasts, the need has arisen to evaluate and monitor its possible harm and benefits in comparison with other screening modalities such as mammography. Recently, the fifth edition of the Breast Imaging Reporting and Data System published by the American College of Radiology has suggested auditing methods for screening breast US. However, the method proposed therein is slightly different from how diagnostic performance was calculated in previous studies on screening breast US. In this article, the background and core aspects of medical audits of breast cancer screening will be reviewed to provide an introduction to the medical auditing of screening breast US, with the goal of helping radiologists to understand and identify potential ways to improve outcomes.
Collapse
Affiliation(s)
- Min Jung Kim
- Department of Radiology, Research Institute of Radiological Science, Severance Hospital, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
13
|
Yoo J, Ahn HS, Kim SJ, Park SH, Seo M, Chong S. Evaluation of Diagnostic Performance of Screening Thyroid Ultrasonography and Imaging Findings of Screening-Detected Thyroid Cancer. Cancer Res Treat 2017; 50:11-18. [PMID: 28231691 PMCID: PMC5784632 DOI: 10.4143/crt.2016.600] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 02/08/2017] [Indexed: 12/13/2022] Open
Abstract
Purpose The purpose of this study was to evaluate the diagnostic performance and cost of screening thyroid ultrasonography (US) in an asymptomatic population and determine the US features of screening-detected thyroid cancer. Materials and Methods This study included 1,845 asymptomatic participants who underwent screening thyroid US between March and August 2012 at the screening center in our hospital. We evaluated the diagnostic performance of screening thyroid US for thyroid cancer and the average cost of diagnosis for each patient. We also determined the characteristic US features of screening-detected thyroid cancer. Results Of the 1,845 subjects, 661 showed no abnormalities, 1,155 exhibited benign thyroid nodules, and 29 exhibited thyroid cancer. Imaging features such as solid composition, hypoechogenicity, taller-than-wide axis, and ill-defined or spiculated margins of nodules were suggestive of malignancy. The rate of detection of cancer was 1.6% (29/1,845), and the sensitivity, specificity, and positive and negative predictive values were 100% (18/18), 98.7% (1,051/1,065), 56.3% (18/32), and 100% (1,051/1,051), respectively. Of 18 patients who underwent thyroidectomy, three (16.7%) had a pathological tumor staging of T3, and four (22.2%) had a pathological nodal staging of N1a. The average cost of diagnosis for each patient with cancer was $7,319. Conclusion Screening thyroid US exhibited a good diagnostic performance, with a feasible social cost of use. This modality demonstrated significant differences in sonographic features between screening-detected cancer and benign nodules.
Collapse
Affiliation(s)
- Jeongin Yoo
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Hye Shin Ahn
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Soo Jin Kim
- Department of Radiology, New Korea Hospital/Human Medical Imaging and Intervention Center, Gimpo, Korea
| | - Sung Hee Park
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| | - Mirinae Seo
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea.,Department of Radiology, Kyung Hee University Hospital, Kyung Hee University College of Medicine, Seoul, Korea
| | - Semin Chong
- Department of Radiology, Chung-Ang University Hospital, Chung-Ang University College of Medicine, Seoul, Korea
| |
Collapse
|
14
|
Kim SY, Kim MJ, Moon HJ, Yoon JH, Kim EK. Application of the downgrade criteria to supplemental screening ultrasound for women with negative mammography but dense breasts. Medicine (Baltimore) 2016; 95:e5279. [PMID: 27858896 PMCID: PMC5591144 DOI: 10.1097/md.0000000000005279] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
We investigated whether the application of the downgrade criteria to supplemental screening ultrasound (US) for women with negative mammography but dense breasts can reduce the rate of Breast Imaging Reporting and Data System (BI-RADS) categories 3 to 4a without a loss of cancer detection.This retrospective study was approved by the Institutional Review Board, and the need to obtain informed consent was waived. A total of 3171 consecutive women (978 women, 1173 women, and 1020 women in the first, second, and third year, respectively) with negative mammography but dense breast who underwent radiologist-performed, hand-held supplemental screening US from March 2010 to February 2013 were included. Downgrade criteria for BI-RADS category 2 were complicated cysts ≤5 mm observed as circumscribed, homogeneous, and hypoechoic lesions and circumscribed oval-shaped solid masses ≤5 mm. Changes in the distribution of BI-RADS category, biopsy rate, and cancer detection yield over 3 years were analyzed. Performances of less-experienced (12 fellows with <2 years of experience) and experienced (3 staffs with >12 years of experience) radiologists were compared. Outcomes of initial examinations (prevalence screening) and noninitial examinations (incidence screening) were compared.Application of the downgrade criteria reduced BI-RADS categories 3 to 4a in both less-experienced (from 39.4% to 16.0%, P < 0.001) and experienced radiologists (from 22.6% to 11.1%, P < 0.001) over 3 years. Biopsy rates also significantly decreased from 6.5% to 2.4% (P < 0.001). Cancer detection yield of supplemental screening US was 2.8 per 1000 examinations (9 of 3171: 2 ductal carcinoma in situ and 7 invasive cancers). There were no differences in cancer detection yield per each year (P = 0.539). There was no interval cancer. In noninitial examinations, BI-RADS categories 3 to 4a rates, biopsy rates, and cancer detection rates were lower compared to initial examinations.Application of the downgrade criteria reduced BI-RADS categories 3 to 4a without a loss of cancer detection. We suggest that our downgrade criteria can be used to reduce the false positive rate in the supplemental screening US. Further large-scale, multicenter, prospective studies are needed to validate the effectiveness of the downgrade criteria.
Collapse
Affiliation(s)
| | | | | | | | - Eun-Kyung Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, South Korea
- Correspondence: Eun-Kyung Kim, Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, 03722 Seoul, South Korea (e-mail: )
| |
Collapse
|
15
|
Nam SY, Ko EY, Han BK, Shin JH, Ko ES, Hahn SY. Breast Imaging Reporting and Data System Category 3 Lesions Detected on Whole-Breast Screening Ultrasound. J Breast Cancer 2016; 19:301-307. [PMID: 27721880 PMCID: PMC5053315 DOI: 10.4048/jbc.2016.19.3.301] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Accepted: 06/17/2016] [Indexed: 12/03/2022] Open
Abstract
Purpose This study assessed the incidence and cancer rate of probably benign lesions detected on bilateral whole-breast screening ultrasound (US), which corresponded to US Breast Imaging Reporting and Data System (BI-RADS) category 3, and evaluated the proper management of those lesions. Methods This study was approved by the Institutional Review Board in our institution, which waived informed patient consent. We retrospectively reviewed US images of 1,666 patients who underwent bilateral whole-breast screening US as a supplemental screening test to negative screening mammography or screening US only. The incidence, clinical course, and cancer rate of screening US-detected probably benign lesions corresponding to US BI-RADS category 3 were investigated, and the size and multiplicity of screening US-detected category 3 lesions were evaluated. Results Probably benign lesions corresponding to US BI-RADS category 3 were detected in 689 of 1,666 patients (41.4%) who underwent screening US. Among them, 653 had follow-up US images for at least 24 months, and among these 653, 190 (29.1%) had multiple bilateral category 3 lesions. Moreover, 539 of 1,666 patients (32.4%) had lesions ≤1 cm in size and 114 of 1,666 (6.8%) had lesions >1 cm (median, 0.82 cm; range, 0.3–4.2 cm). Four of the 653 patients (0.6%) showed suspicious interval changes and were categorized into BI-RADS category 4. Biopsy analysis confirmed only one lesion as invasive ductal carcinoma at the 6-month follow-up; another lesion was an intraductal papilloma and the remaining two were fibroadenomas. Overall cancer rate of the screening US-detected BI-RADS category 3 lesions was 0.2%. Conclusion The incidence of category 3 lesions detected on screening US only was very high, but the cancer rate was very low. Therefore, in an average-risk population, routine screening US is preferable over short-term follow-up for BI-RADS category 3 lesions detected on whole-breast screening US.
Collapse
Affiliation(s)
- Sang Yu Nam
- Department of Radiology, Gachon University Gil Medical Center, Gachon University of Medicine and Science, Incheon, Korea
| | - Eun Young Ko
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Boo-Kyung Han
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jung Hee Shin
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Eun Sook Ko
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Soo Yeon Hahn
- Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
16
|
Zhao S, Mei Y, Wang J, Zhang K, Ma R. Different Levels of CEA, CA153 and CA125 in Milk and Benign and Malignant Nipple Discharge. PLoS One 2016; 11:e0157639. [PMID: 27327081 PMCID: PMC4915693 DOI: 10.1371/journal.pone.0157639] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 06/02/2016] [Indexed: 11/18/2022] Open
Abstract
Background The aim of this study was to assess the diagnostic values of three breast tumor markers (i.e., CEA, CA153 and CA125) in milk and nipple discharge in the prediction of different breast diseases diagnoses. Methods Three hundred thirty-six patients (96 breast cancer and 240 benign disease patients) with nipple discharge and a control group of 56 healthy parturient participants were enrolled in the present study. Nipple discharge samples were preoperatively collected from the patients, and milk was collected from the colostrum of the parturient participants. The samples were assayed for the CEA, CA153 and CA125 levels. Cutoff values were determined for the detection of breast diseases using ROC curves. Results The levels of CEA, CA153 and CA125 were significantly different between the nipple discharge and the milk (all ps < 0.001). In the nipple discharge, the CEA and CA153 levels in the breast cancer group were significantly greater than those in the benign group (all ps < 0.001), and cutoff values of 263.3 ng/mL and 1235.3 U/mL, respectively, were established. However, the expression of CA125 did not differ significantly between the breast cancer and benign groups. Conclusion Differences in the apparent expression levels of CEA, CA153 and CA125 in patients with nipple discharge and healthy persons were validated. The present data suggest that CEA and CA153 might potentially be useful in the differential diagnoses of benign tumors and breast cancer. CA125 did not seem to be useful for breast cancer detection.
Collapse
Affiliation(s)
- Song Zhao
- Department of Breast Surgery, Qilu Hospital of Shandong University, Jinan, Shandong, China
| | - Yu Mei
- Department of Breast Surgery, Jinan Maternity and Child Care Hospital, Jinan, Shandong, PR China
| | - Jianli Wang
- Department of Pathophysiology, School of Medicine, Shandong University, Shandong, China
| | - Kai Zhang
- Department of Breast Surgery, Qilu Hospital of Shandong University, Jinan, Shandong, China
- * E-mail: (RM); (KZ)
| | - Rong Ma
- Department of Breast Surgery, Qilu Hospital of Shandong University, Jinan, Shandong, China
- * E-mail: (RM); (KZ)
| |
Collapse
|
17
|
Hwang JY, Han BK, Ko EY, Shin JH, Hahn SY, Nam MY. Screening Ultrasound in Women with Negative Mammography: Outcome Analysis. Yonsei Med J 2015; 56:1352-8. [PMID: 26256979 PMCID: PMC4541666 DOI: 10.3349/ymj.2015.56.5.1352] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2014] [Revised: 01/10/2015] [Accepted: 01/14/2015] [Indexed: 11/27/2022] Open
Abstract
PURPOSE To show the results of an audit of screening breast ultrasound (US) in women with negative mammography in a single institution and to analyze US-detected cancers within a year and interval cancers. MATERIALS AND METHODS During the year of 2006, 1974 women with negative mammography were screened with US in our screening center, and 1727 among them had pathologic results or any follow up breast examinations more than a year. We analyzed the distribution of Breast Imaging Reporting and Data System (BI-RADS) category and the performance outcome through follow up. RESULTS Among 1727 women (age, 30-76 years, median 49.5 years), 1349 women (78.1%) showed dense breasts on mammography, 762 (44.1%) had previous breast US, and 25 women (1.4%) had a personal history of breast cancers. Test negatives were 94.2% (1.627/1727) [BI-RADS category 1 in 885 (51.2%), 2 in 742 (43.0%)]. The recall rate (=BI-RADS category 3, 4, 5) was 5.8%. Eight cancers were additionally detected with US (yield, 4.6 per 1000). The sensitivity, specificity, and positive predictive value (PPV1, PPV2) were 88.9%, 94.6%, 8.0%, and 28.0%, respectively. Eight of nine true positive cancers were stage I or in-situ cancers. One interval cancer was stage I cancer from BI-RADS category 2. CONCLUSION Screening US detected 4.6 additional cancers among 1000. The recall rate was 5.8%, which is in lower bound of acceptable range of mammography (5-12%), according to American College of Radiology standard.
Collapse
Affiliation(s)
- Ji-Young Hwang
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
- Department of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, Seoul, Korea
| | - Boo-Kyung Han
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
| | - Eun Young Ko
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Jung Hee Shin
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Soo Yeon Hahn
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| | - Mee Young Nam
- Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
| |
Collapse
|
18
|
Moon HJ, Kim EK. Characteristics of breast cancer detected by supplementary screening ultrasonography. Ultrasonography 2015; 34:153-6. [PMID: 26062638 PMCID: PMC4484284 DOI: 10.14366/usg.15029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2015] [Revised: 05/24/2015] [Accepted: 05/24/2015] [Indexed: 11/24/2022] Open
Affiliation(s)
- Hee Jung Moon
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| | - Eun-Kyung Kim
- Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
19
|
Improved visualization of breast cancer features in multifocal carcinoma using phase-contrast and dark-field mammography: an ex vivo study. Eur Radiol 2015; 25:3659-68. [PMID: 25956934 PMCID: PMC4636518 DOI: 10.1007/s00330-015-3773-5] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2014] [Revised: 12/19/2014] [Accepted: 04/07/2015] [Indexed: 11/21/2022]
Abstract
Objectives Conventional X-ray attenuation-based contrast is inherently low for the soft-tissue components of the female breast. To overcome this limitation, we investigate the diagnostic merits arising from dark-field mammography by means of certain tumour structures enclosed within freshly dissected mastectomy samples. Methods We performed grating-based absorption, absolute phase and dark-field mammography of three freshly dissected mastectomy samples containing bi- and multifocal carcinoma using a compact, laboratory Talbot-Lau interferometer. Preoperative in vivo imaging (digital mammography, ultrasound, MRI), postoperative histopathological analysis and ex vivo digital mammograms of all samples were acquired for the diagnostic verification of our results. Results In the diagnosis of multifocal tumour growth, dark-field mammography seems superior to standard breast imaging modalities, providing a better resolution of small, calcified tumour nodules, demarcation of tumour boundaries with desmoplastic stromal response and spiculated soft-tissue strands extending from an invasive ductal breast cancer. Conclusions On the basis of selected cases, we demonstrate that dark-field mammography is capable of outperforming conventional mammographic imaging of tumour features in both calcified and non-calcified tumours. Presuming dose optimization, our results encourage further studies on larger patient cohorts to identify those patients that will benefit the most from this promising additional imaging modality. Key Points • X-ray dark-field mammography provides significantly improved visualization of tumour features • X-ray dark-field mammography is capable of outperforming conventional mammographic imaging • X-ray dark-field mammography provides imaging sensitivity towards highly dispersed calcium grains
Collapse
|