1
|
Grande F, Cesare PM, Mochi Zamperoli E, Gianoli CM, Mollica F, Catapano S. Evaluation of Tension and Deformation in a Mandibular Toronto Bridge Anchored on Three Fixtures Using Different Framework Materials, Abutment Systems, and Loading Conditions: A FEM Analysis. Eur J Dent 2023; 17:1097-1105. [PMID: 36696917 PMCID: PMC10756777 DOI: 10.1055/s-0042-1758785] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023] Open
Abstract
OBJECTIVE The aim of this study was to investigate by finite element method analysis the behaviour of a three-implant mandible Toronto framework made by three different materials, with two abutment systems and two loading conditions. MATERIALS AND METHODS Three implants were virtually inserted in a mandible model in positions 3.6, 4.1, and 4.6. Three prosthetic framework bars with the same design and dimension (4.8 × 5.5 mm) were projected. The variables introduced in the computer model were the framework materials (glass fiber reinforced resin, Co-Cr, TiAl6V4), the abutment systems (Multi-Unit-Abutment [MUA]/OT-Bridge), and the loading conditions (500 N vertical load on all the framework area and 400 N on a 7-mm distal cantilever). The computer was programmed with physical properties of the materials as derived from the literature. Maximum tension and deformation values for each variable were registered at framework, screws, and abutment level and then compared. RESULTS Metal frameworks Cr-Co and TiAl6V4 resulted in lower deformation than glass fiber-reinforced resin frameworks while presenting higher tension values. The OT-Bridge exhibited lower maximum tension and deformation values than the MUA system. The first loading condition reached higher tension and deformation values than the second and it resulted in more uniformly distributed load on all the framework area, especially with the OT-Bridge system. CONCLUSION More rigid materials and OT-Bridge system decrease the deformation on the prosthetic components. Tension stresses are more uniformly distributed with glass fiber-reinforced resin, in the OT-Bridge system and avoiding cantilever loading.
Collapse
Affiliation(s)
- Francesco Grande
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin, Italy
| | | | | | | | | | - Santo Catapano
- Department of Prosthodontics, University of Ferrara, Ferrara, Italy
| |
Collapse
|
2
|
Tallarico M, Fiorillo L, Montanari M, Scrascia R, Cristache CM, Ferrari E, Casucci A, Xhanari E, Lupi SM, Ieria I, Baldoni E, Rodriguez y Baena R, Cervino G. One-Year Multicenter Randomised Controlled Trial Comparing OT Equator® and Locator Attachments to Retain an Early Loaded Implant Overdenture on Two Implants. Int J Biomater 2023; 2023:2745262. [PMID: 37457392 PMCID: PMC10348852 DOI: 10.1155/2023/2745262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 06/06/2022] [Accepted: 06/27/2023] [Indexed: 07/18/2023] Open
Abstract
This investigation aimed to compare the effectiveness of the OT Equator® (Rhein, Bologna, Italy) and the Locator attachment systems used to retain early loaded implant-retained overdentures. This study was designed as a multicenter randomised controlled trial of parallel groups. After implant placement, the patients were randomised to receive OT Equator® attachments in the test group or Locator attachments in the control group. The outcome measures were implant and prosthetic success and survival rates, any biological and technical complication, marginal bone loss, patients' satisfaction, and periodontal parameters. Overall, 42 patients were consecutively enrolled and treated. One implant was lost in the control group, while no implants were lost in the test group. No prostheses failed in both groups. Only a few complications were experienced in both groups. The main was represented by loss of retention of the attachments (retentive caps). The OT Equator® attachment showed statistically lower periodontal parameters. In conclusion, both attachment systems were suitable for overdenture implant retention.
Collapse
Affiliation(s)
| | - Luca Fiorillo
- School of Dentistry, Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Via Consolare Valeria 1, Messina 98125, Italy
- School of Dentistry, Aldent University, Tirana 1001, Albania
- Multidisciplinary Department of Medical-Surgical and Odontostomatological Specialties, University of Campania “Luigi Vanvitelli”, Naples 80121, Italy
- Department of Prosthodontics, Dr D. Y. Patil Dental College and Hospital, Dr D. Y. Patil Vidyapeeth, Pimpri, Pune 411018, India
| | | | | | - Corina Marilena Cristache
- Faculty of Midwifery and Medical Assisting, “Carol Davila” University of Medicine and Pharmacy, Bucharest 020021, Romania
| | | | | | - Erta Xhanari
- School of Dentistry, Aldent University, Tirana 1001, Albania
| | | | | | | | | | - Gabriele Cervino
- School of Dentistry, Department of Biomedical and Dental Sciences and Morphofunctional Imaging, University of Messina, Via Consolare Valeria 1, Messina 98125, Italy
| |
Collapse
|
3
|
Bekhit SS, Abdelhamid AM, Metwally NA. Evaluation of prosthetic screw loosening in all-on-four implant-supported restorations with two different connection systems. J Prosthet Dent 2023:S0022-3913(23)00366-9. [PMID: 37414597 DOI: 10.1016/j.prosdent.2023.05.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2023] [Revised: 05/17/2023] [Accepted: 05/18/2023] [Indexed: 07/08/2023]
Abstract
STATEMENT OF PROBLEM: The OT BRIDGE connection system can be an alternative to multiunit abutments (MUA) for patients with all-on-four implant-supported restorations. However, the amount of prosthetic screw loosening of the OT BRIDGE in comparison with the MUA used in all-on-four implant restorations is unclear. PURPOSE The purpose of this in vitro study was to compare the loss of removal torque in the absence of load and after dynamic cyclic loading between the 2 different connection systems: OT BRIDGE attachment and MUA used in all-on-four implant-supported restorations. MATERIAL AND METHODS Four dummy implants (Neobiotech Co Ltd) were inserted into an edentulous mandibular model according to the all-on-four concept. Sixteen screw-retained restorations were digitally fabricated and assigned to 2 groups: the OT BRIDGE group received 8 restorations connected with OT BRIDGE (Rhein 83 srl); the MUA group received 8 restorations connected with MUA (Neobiotech Co Ltd). Restorations were tightened to the abutments according to the manufacturers' recommendations by using a digital torque gauge. The removal torque value (RTV) was measured with the same digital torque gauge. After retightening, dynamic cyclic loading was applied by using a pneumatic custom cyclic loading machine. RTV after loading was measured with the same torque gauge. From the RTVs measured, the ratios of removal torque loss (RTL) before and after loading and the difference between before and after loading were calculated. Data were analyzed by using the independent samples t test, paired samples t test, and mixed model analysis of variance (α=.05). RESULTS The OT BRIDGE showed significantly higher RTL before loading ratio (%) than the MUA in anterior abutments (P=.002) and posterior abutments (P=.003), as well as significantly higher RTL after loading ratio (%) in anterior abutments (P=.02). The MUA showed significantly higher RTL difference between before and after loading ratio (%) than the OT BRIDGE in both anterior (P=.001) and posterior abutments (P<.001). In both systems, posterior abutments showed significantly higher RTL after loading ratio (%) than anterior abutments (P<.001). CONCLUSIONS Posterior abutments showed more prosthetic screw loosening than anterior ones in both systems. The OT BRIDGE showed higher total prosthetic screw loosening than the MUA, although this was not significant in posterior abutments after loading. However, the OT BRIDGE was less affected by cyclic loading than the MUA.
Collapse
Affiliation(s)
- Samuel Sami Bekhit
- Instructor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt.
| | - Ahmed M Abdelhamid
- Professor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Nayrouz Adel Metwally
- Lecturer, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
4
|
Implant Survival Rate and Prosthetic Complications of OT Equator Retained Maxillary Overdenture: A Cohort Study. PROSTHESIS 2022. [DOI: 10.3390/prosthesis4040057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
(1) Background: The overdenture is a complete denture, an implant-supported prosthesis, that the patient can remove at home for the usual oral hygiene procedures, thanks to a simple and intuitive anchoring system. Clinically, the execution of this rehabilitation for the lower arch is often favored, but when it is necessary to limit the extension of the palate in the upper arch, it can represent the least invasive and economic solution. The aim of the study is to analyze post-loading implant loss for implant-supported prostheses in the edentulous upper jaw. (2) Methods: This retrospective study was carried out on patients who received a superior overdenture on four implants for rehabilitation. A total of 42 patients were included in this study and initially evaluated clinically and radiographically. The follow-up period for patients after delivery of the upper overdenture is between 48 and 72 months. A total of 168 implants were inserted and monitored in this period. Clinical and radiographic tests were carried out on all 168 implants, with constant re-evaluation. (3) Results: The overall implant survival rate is 92.9%, a value that corresponds to those present in the literature in previously published studies. There were few prosthetic complications, mainly the detachment of anterior prosthetic teeth. (4) Conclusions: Most of these complete prostheses, which as antagonist had another previously made overdenture on four or on two implants, achieved excellent success rates in this study at 72 months.
Collapse
|
5
|
Grande F, Pozzan MC, Marconato R, Mollica F, Catapano S. Evaluation of Load Distribution in a Mandibular Model with Four Implants Depending on the Number of Prosthetic Screws Used for OT-Bridge System: A Finite Element Analysis (FEA). MATERIALS (BASEL, SWITZERLAND) 2022; 15:ma15227963. [PMID: 36431449 PMCID: PMC9699052 DOI: 10.3390/ma15227963] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2022] [Revised: 11/09/2022] [Accepted: 11/09/2022] [Indexed: 05/28/2023]
Abstract
In full-arch implant rehabilitations, when the anterior screw abutment channel compromises the aesthetic of the patient, the OT-Bridge system used with its Seeger rings may provide the necessary retention of the prosthesis. However, no studies have evaluated the forces generated at the Seeger level during loading. This Finite Element Analysis aims to investigate the mechanical behavior of Seeger rings in a mandibular model with four implants and an OT-Bridge system, used without one or two anterior prosthetic screws. A 400 N unilateral load was virtually applied on a 7 mm distal cantilever. Two different variables were considered: the constraint conditions using two or three screws instead of four and the three different framework materials (fiberglass reinforced resin, cobalt-chrome, TiAl6V4). The FEA analysis exhibited tensile and compressive forces on the Seeger closest to the loading point. With the resin framework, a tension force on abutment 3.3 generates a displacement from 5 to 10 times greater than that respectively expressed in metal framework materials. In a full-arch rehabilitation with four implants, the case with three prosthetic screws seems to be a safer and more predictable configuration instead of two. Considering the stress value exhibited and the mechanical properties of the Seeger, the presence of only two prosthetic screws could lead to permanent deformation of the Seeger in the screwless abutment closest to the loading point.
Collapse
Affiliation(s)
- Francesco Grande
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
- Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Via Nizza, 230, 10126 Torino, Italy
| | - Mario Cesare Pozzan
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| | - Raul Marconato
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| | - Francesco Mollica
- Department of Engineering, University of Ferrara, 44121 Ferrara, Italy
| | - Santo Catapano
- Department of Prosthodontics, University of Ferrara, Via Luigi Borsari 46, 44121 Ferrara, Italy
| |
Collapse
|
6
|
Assessment of Preload Loss after Cyclic Loading in the OT Bridge System in an “All-on-Four” Rehabilitation Model in the Absence of One and Two Prosthesis Screws. MATERIALS 2022; 15:ma15041582. [PMID: 35208121 PMCID: PMC8879715 DOI: 10.3390/ma15041582] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Revised: 02/17/2022] [Accepted: 02/18/2022] [Indexed: 01/28/2023]
Abstract
The aim of this study was to evaluate the stability of prosthetic screws after applying cyclic loadings in an “all-on-four” rehabilitation model with the OT Bridge system. The model was tested both with and without anterior screws. Four implant analogues following the “all-on-four” concept were inserted in an edentulous mandibular resin model. An OT Bridge system with a Cr–Co prosthetic framework was fabricated. Depending on the presence or absence of one or two anterior screws on the implant analogues, three groups were created, i.e., Gr.1: three tightening screws, Gr.2: two tightening screws, Control Group: four tightening screws. Each single group underwent subsequent 400,000 cyclic loads, simulating approximately a year of chewing by using a dynamometer machine. This cycle was repeated five times for each group, and preload loss values were evaluated on each prosthetic screw after each cycle. All the data obtained were analyzed by one-way ANOVA and Student’s t-test. No statistically significant differences after intragroup analysis were found. A statistically significant difference within the Gr.1 between the screws in positions 33 and 36, equal to 15.2% (p-value = 0.0176), was found. The OT Bridge seems a useful system to maintain the retention of a prosthesis during mechanical stress conditions even in the absence of one screw in an “all-on-four” rehabilitation. This could represent a good solution to solve the esthetic problem of the screw buccal access hole for fixed solutions.
Collapse
|
7
|
Tallarico M, Lumbau AMI, Meloni SM, Ieria I, Park CJ, Zadrożny L, Xhanari E, Pisano M. Five-Year Prospective Study on Implant Failure and Marginal Bone Remodeling Expected Using Bone Level Implants with Sandblasted/Acid-Etched Surface and Conical Connection. Eur J Dent 2022; 16:787-795. [PMID: 34991163 DOI: 10.1055/s-0041-1739439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022] Open
Abstract
OBJECTIVE The purpose of the present prospective, case-series study was to report implant survival rate and marginal bone remodeling expected 5 years after loading using dental implants placed in daily practice. MATERIALS AND METHODS This research was designed as an open-cohort, prospective, case-series evaluation. Any partially or completely edentulous patient, scheduled to receive at least one bone level implant, was considered eligible for this study. Primary outcome measurements were: implant and prosthetic cumulative survival rate and any complications experienced up to the 5-year follow-up. Secondary outcome measures were: thickness of gingival biotype, implant insertion torque, implant stability quotient, and marginal bone loss (MBL). RESULTS Ninety consecutive patients (34 males and 56 females, aged between 24 and 81 years old [mean: 53.2 ± 15.4]) with 243 inserted implants were followed for at least 5 years after loading (mean: 65.4 ± 3.1 months; range from 60 to 72). At the 1-year follow-up, no drop-outs were recorded, but 17 patients (18.9%) with 18 restorations (12.6%) delivered on 34 implants (14%) were lost at the 5-year examination. At the 5-year follow-up examination, six implants lost osseointegration (97.5%). In the same period, four prostheses failed (97.2%). Five complications were reported in five different patients (prosthetic success rate was 96.5%, at patient level). Five years after loading, the mean MBL was 0.41 ± 0.30 mm. The difference from the 1-year data was 0.04 ± 0.19 mm. A statistically significant higher MBL was found for smokers, and patients with thin gingival biotype. The mean implant insertion torque was 42.9 ± 4.8 Ncm (range from 15 to 45 Ncm). Two-hundred and three implants (83.5%) were inserted with an insertion torque ≥35 and ≤45 Ncm. CONCLUSIONS High implant survival and success rate could be expected with stable marginal bone remodeling up to 5 years after loading. Smoking and thin tissue biotype were the most important variabilities associated with higher MBL. Further research studies are needed to confirm these results.
Collapse
Affiliation(s)
| | | | | | | | - Chang-Joo Park
- Department of Dentistry, Division of Oral and Maxillofacial Surgery, College of Medicine, Hanyang University, Seoul, Korea
| | - Lukasz Zadrożny
- Department of Dental Propedeutics and Prophylaxis, Medical University of Warsaw, Warsaw, Poland
| | - Erta Xhanari
- Department of Implantology and Prosthetic Aspects, Master of Science in Dentistry Program, Aldent University, Tirana, Albania
| | - Milena Pisano
- School of Dentistry, University of Sassari, Sassari, Italy
| |
Collapse
|
8
|
A One-Year, Multicenter, Retrospective Evaluation of Narrow and Low-Profile Abutments Used to Rehabilitate Complete Edentulous Lower Arches: The OT Bridge Concept. PROSTHESIS 2020. [DOI: 10.3390/prosthesis2040033] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Purpose: To evaluate preliminary data on survival and success rates of immediately loaded, screw-retained, restorations delivered on lower arches using narrow and low-profile OT Equator abutments. Methods: This retrospective study analyzed data of patients rehabilitated with OT Bridge (fixed prosthetic system built on OT Equator) prosthetic concept from November 2017 to February 2019 in five different centers. Outcome measures were implant and prosthetic survival rates, biological and technical complications, marginal bone loss (MBL), oral health impact profile (OHIP), bleeding on probing, and plaque index. Results: A total of 60 implants were inserted in 12 patients. Patients were followed for a mean period of 15.8 months (range 12–24). All the patients received OT Equator as intermediate abutments. Four out of 60 implants were connected to the prosthetic framework using only the Seeger system, without a screw. One year after loading, three implants failed (implant survival rate of 95.0%) in two patients. No prosthesis failed and no major biological and technical complications were experienced. One year after initial loading, the marginal bone level was 0.32 ± 0.2 mm. The OHIP before treatment was 87.7 ± 6.0. One year after treatment, OHIP was 23.6 ± 1.2. The difference was statistically significant (64.1 ± 7.2; p = 0.0000). One year after loading, 8.9% of the examined implant sites present positive bleeding on probing, while 5.8% of the implant sites presented plaque. Conclusions: The OT Equator abutments showed successful results when used to support mandible fixed dental prosthesis delivered on 4–6 implants. Whole prosthetic survival and success rates, high patient satisfaction, and good biological parameters were experienced one year after function. Further prospective studies are needed to confirm these preliminary results.
Collapse
|