1
|
Ries M, Kelava I, Ajduk J, Košec A, Žaja R, Trotić R. Correlation between neural response telemetry measurements and fitting levels. Int J Pediatr Otorhinolaryngol 2024; 182:112001. [PMID: 38885546 DOI: 10.1016/j.ijporl.2024.112001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/11/2024] [Revised: 05/30/2024] [Accepted: 06/02/2024] [Indexed: 06/20/2024]
Abstract
INTRODUCTION The neural response telemetry (NRT) is a standard procedure in cochlear implantation mostly used to determine the functionality of implanted device and to check auditory nerve responds to the stimulus. Correlation between NRT measurements and subjective threshold (T) and maximum comfort (C) levels has been reported but results are inconsistent, and it is still not clear which of the NRT measurements could be the most useful in predicting fitting levels. PURPOSE In our study we aimed to investigate which NRT measurement corresponds better to fitting levels. Impedance (IMP), Evoked Action Potential (ECAP) threshold and amplitude growth function (AGF) slope values were included in the study. Also, we tried to identify cochlear area at which the connection between NRT measurements and fitting levels would be the most pronounced. MATERIALS AND METHODS Thirty-one children implanted with Cochlear device were included in this retrospective study. IMP, ECAP thresholds and AGF were obtained intra-operatively and 12 months after surgery at electrodes 5, 11 and 19 as representative for each part of cochlea. Subjective T and C levels were obtained 12 months after the surgery during cochlear fitting. RESULTS ECAP thresholds obtained 12 months after surgery showed statistically significant correlation to both T and C levels at all 3 selected electrodes. IMP correlated with C levels while AGF showed tendency to correlate with T levels. However, these correlations were not statistically significant for all electrodes. CONCLUSION ECAP threshold measurements correlated to T and C values better than AGF slope and IMP. Measurements obtained twelve months after surgery seems to be more predictive of T and C values compared to intra-operative measurements. The best correlation between ECAP threshold and T and C values was found at electrode 11 suggesting NRT measurements at mid-portion cochlear region to be the most useful in predicting fitting levels.
Collapse
Affiliation(s)
- Mihael Ries
- Department of Otorhinolaryngology, Sisters of Charity University Hospital Center, Vinogradska Cesta 29, Zagreb, Croatia; School of Medicine, University of Zagreb, Šalata 3a, Zagreb, Croatia
| | - Iva Kelava
- Department of Otorhinolaryngology, Sisters of Charity University Hospital Center, Vinogradska Cesta 29, Zagreb, Croatia.
| | - Jakov Ajduk
- Department of Otorhinolaryngology, Sisters of Charity University Hospital Center, Vinogradska Cesta 29, Zagreb, Croatia; School of Medicine, University of Zagreb, Šalata 3a, Zagreb, Croatia
| | - Andro Košec
- Department of Otorhinolaryngology, Sisters of Charity University Hospital Center, Vinogradska Cesta 29, Zagreb, Croatia; School of Medicine, University of Zagreb, Šalata 3a, Zagreb, Croatia
| | - Roko Žaja
- School of Medicine, University of Zagreb, Šalata 3a, Zagreb, Croatia
| | - Robert Trotić
- Department of Otorhinolaryngology, Sisters of Charity University Hospital Center, Vinogradska Cesta 29, Zagreb, Croatia
| |
Collapse
|
2
|
Espina González C, Morant Ventura A, Pla Gil I, Aragonés Redó M, Pérez Carbonell T, Marco Algarra J. Variation of electrical impedance over 5 years post-implantation and relationship with the maximum comfort level (MCL) in adults with cochlear implants. ACTA OTORRINOLARINGOLOGICA ESPANOLA 2024; 75:23-30. [PMID: 38224870 DOI: 10.1016/j.otoeng.2024.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2022] [Accepted: 04/29/2023] [Indexed: 01/17/2024]
Abstract
INTRODUCTION The maximum comfort level (MCL), threshold level (THR) and electrical impedance change in the postoperative period of the cochlear implant for months until they stabilize. The objective of this article is to establish the variation during 5 post-surgical years of impedance, and its relationship with MCL in unilaterally implanted adults. METHODS Retrospective study over 5 years, with 78 adult patients implanted with MED-EL in a tertiary hospital from the year 2000 to 2015. The variation in impedance, MCL and the relationship between them were analyzed in basal (9-12), medial (5-8) and apical electrodes (1-4), performing an inferential ANOVA analysis of repeated measures with comparisons between consecutive times, corrected with Bonferroni criteria. RESULTS 33 men (42.3%) and 45 women (57.7%), with a mean age of 52.7±14.6 years. "Stability" was considered the time of follow-up without statistically significant differences between one visit and the next. Changes in impedance in medial electrodes ceased to be statistically significant at 3 months, and in apicals at 6 months, with mean values of 5.84 and 6.43kΩ. MCL stabilized at 2 years in basal and apical electrodes, and at 3 years in medial, with mean values of 24.9, 22.7, and 25.6qu. There was a correlation between MCL and impedance in medium electrodes up to 3 months and in apical ones up to one year. CONCLUSIONS Electrical impedance drops significantly in medial and apical electrodes up to 3 and 6 months. MCL increases significantly up to two years. Impedance is related to MCL up to 6 months.
Collapse
Affiliation(s)
- Clara Espina González
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain; Servicio de Otorrinolaringología, Hospital del Mar, Barcelona, Spain.
| | - Antonio Morant Ventura
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain
| | - Ignacio Pla Gil
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain
| | - María Aragonés Redó
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain; Servicio de Otorrinolaringología, Hospital Arnau de Vilanova, Valencia, Spain
| | - Tomás Pérez Carbonell
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain
| | - Jaime Marco Algarra
- Servicio de Otorrinolaringología, Hospital Clínico Universitario de Valencia, Universitat de València, Valencia, Spain
| |
Collapse
|
3
|
Lambriks L, van Hoof M, Debruyne J, Janssen M, Hof J, Hellingman K, Devocht E, George E. Toward neural health measurements for cochlear implantation: The relationship among electrode positioning, the electrically evoked action potential, impedances and behavioral stimulation levels. Front Neurol 2023; 14:1093265. [PMID: 36846130 PMCID: PMC9948626 DOI: 10.3389/fneur.2023.1093265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/10/2023] [Indexed: 02/11/2023] Open
Abstract
Introduction Estimating differences in neural health across different sites within the individual cochlea potentially enables clinical applications for subjects with a cochlear implant. The electrically evoked compound action potential (ECAP) is a measure of neural excitability that possibly provides an indication of a neural condition. There are many factors, however, that affect this measure and increase the uncertainty of its interpretation. To better characterize the ECAP response, its relationship with electrode positioning, impedances, and behavioral stimulation levels was explored. Methods A total of 14 adult subjects implanted with an Advanced Bionics cochlear electrode array were prospectively followed up from surgery to 6 months postoperative. Insertion depth, distance to the modiolus, and distance to the medial wall were assessed for each electrode by postoperative CT analysis. ECAPs were measured intraoperatively and at three visits postoperatively on all 16 electrodes using the NRI feature of clinical programming software and characterized using multiple parameters. Impedances and behavioral stimulation levels were measured at every fitting session. Results Patterns in ECAPs and impedances were consistent over time, but high variability existed among subjects and between different positions in the cochlea. Electrodes located closer to the apex of the cochlea and closer to the modiolus generally showed higher neural excitation and higher impedances. Maximum loudness comfort levels were correlated strongly with the level of current needed to elicit a response of 100 μV ECAP. Conclusion Multiple factors contribute to the ECAP response in subjects with a cochlear implant. Further research might address whether the ECAP parameters used in this study will benefit clinical electrode fitting or the assessment of auditory neuron integrity.
Collapse
Affiliation(s)
- Lars Lambriks
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,*Correspondence: Lars Lambriks ✉
| | - Marc van Hoof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Joke Debruyne
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Miranda Janssen
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands,Department of Methodology and Statistics, Care and Public Health Research Institute, Maastricht University, Maastricht, Netherlands
| | - Janny Hof
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Katja Hellingman
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Elke Devocht
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| | - Erwin George
- Department of ENT/Audiology, School for Mental Health and NeuroScience, Maastricht University Medical Centre, Maastricht, Netherlands
| |
Collapse
|
4
|
Leblans M, Sismono F, Vanpoucke F, van Dinther J, Lerut B, Kuhweide R, Offeciers E, Zarowski A. Novel Impedance Measures as Biomarker for Intracochlear Fibrosis. Hear Res 2022; 426:108563. [DOI: 10.1016/j.heares.2022.108563] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 04/05/2022] [Accepted: 06/15/2022] [Indexed: 11/04/2022]
|
5
|
Brotto D, Caserta E, Sorrentino F, Favaretto N, Marioni G, Martini A, Bovo R, Gheller F, Trevisi P. Long-Term Impedance Trend in Cochlear Implant Users with Genetically Determined Congenital Profound Hearing Loss. J Am Acad Audiol 2022; 33:105-114. [PMID: 35577055 DOI: 10.1055/s-0041-1739290] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
BACKGROUND Impedance is a basic parameter registered at any cochlear implant (CI) fitting section. It is useful in monitoring electrode functioning and the status of the surrounding anatomical structures. PURPOSE The main aim of this study is to evaluate the 5-year impedance-value trend in patients affected by congenital genetically determined profound hearing loss implanted with Cochlear Nucleus devices. RESEARCH DESIGN Observational, retrospective, monocentric study. STUDY SAMPLE Twenty-seven consecutive patients (9 females: 12.0 ± 7.6 years old; range: 4.2-40.4) with genetic diagnosis of GJB2 mutation causing congenital profound hearing loss who underwent cochlear implantation from 2010 to 2020 with good auditory benefit. INTERVENTION Impedance values of the CIs were obtained from the CIs' programming software that registers those parameters for each follow-up section of each patient. DATA COLLECTION AND ANALYSIS Impedance values were measured over time (activation, 6, 12, 24, and 60 months after cochlear implantation), for each of the 22 electrodes, in common ground, monopolar 1, monopolar 2, and monopolar 1 + 2 stimulation modes. RESULTS A significant variation was found between CI activation and 6-month follow-up. This difference was found for each of the 22 electrodes. Electrodes 1 to 4 showed higher impedance values compared with all other electrodes in each time interval. Repeated-measures analysis of variance ruled out significant variations in impedance values from 6-month to 5-year follow-up. CONCLUSIONS Impedance values were extremely stable after activation, at least for the first 5 years. In these cases, even minimal impedance variations should be carefully evaluated for their possible implications on hearing performance.
Collapse
Affiliation(s)
- Davide Brotto
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Ezio Caserta
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Flavia Sorrentino
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Niccolò Favaretto
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Gino Marioni
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Alessandro Martini
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Roberto Bovo
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Flavia Gheller
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| | - Patrizia Trevisi
- Section of Otorhinolaryngology - Head and Neck Surgery, Department of Neurosciences, University of Padova, Padova, Italy
| |
Collapse
|