1
|
Alonso-Ojembarrena A, Gregorio-Hernández R, Raimondi F. Neonatal point-of-care lung ultrasound: what should be known and done out of the NICU? Eur J Pediatr 2024; 183:1555-1565. [PMID: 38315204 DOI: 10.1007/s00431-023-05375-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2023] [Revised: 12/05/2023] [Accepted: 12/06/2023] [Indexed: 02/07/2024]
Abstract
Lung ultrasound is rapidly becoming a useful tool in the care of neonates: its ease of use, reproducibility, low cost, and negligible side effects make it a very suitable tool for the respiratory care of all neonates. This technique has been extensively studied by different approaches in neonatal intensive care unit (NICU), both for diagnostic and prognostic aims and to guide respiratory treatments. However, many neonates are being born in level I/II hospitals without NICU facilities so all pediatricians, not just neonatal intensivists, should be aware of its potential. This is made possible by the increasing access to ultrasound machines in a modern hospital setting. In this review, we describe the ultrasonographic characteristics of the normal neonatal lung. We also discuss the ultrasound features of main neonatal respiratory diseases: transient tachypnea of the neonate (TTN), respiratory distress syndrome (RDS), meconium aspiration syndrome (MAS), pneumothorax (PNX), pleural effusion (PE), or pneumonia. Finally, we mention two functional approaches to lung ultrasound: 1. The use of lung ultrasound in level I delivery centers as a mean to assess the severity of neonatal respiratory distress and request a transport to a higher degree structure in a timely fashion. 2. The prognostic accuracy of lung ultrasound for early and targeted surfactant replacement. CONCLUSION LU is still a useful tool in level I/II neonatal units, both for diagnostic and functional issues. WHAT IS KNOWN • Neonatal lung ultrasound has been recently introduced in the usual care in many Neonatal Intensive Care Units. WHAT IS NEW • It also has many advantages in level I/II neonatal units, both for neonatologist or even pediatricians that treat neonates in those sites.
Collapse
Affiliation(s)
- Almudena Alonso-Ojembarrena
- Neonatal Intensive Care Unit, Puerta del Mar University Hospital, Avenida Ana de Viya, 11, 11009, Cádiz, Spain.
- Biomedical Research and Innovation Institute of Cádiz (INiBICA), Research Unit, Puerta del Mar University Hospital, Cádiz, Spain.
| | | | - Francesco Raimondi
- Division of Neonatology, Department of Translational Medical Sciences, Università Federico II Di Napoli, Naples, Italy
| |
Collapse
|
2
|
Huang P, Chen D, Liu X, Zhang X, Song X. Diagnostic value of bedside lung ultrasound and 12-zone score in the 65 cases of neonatal respiratory distress syndrome and its severity. Biomed Eng Online 2024; 23:29. [PMID: 38448872 PMCID: PMC10918994 DOI: 10.1186/s12938-024-01224-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Accepted: 02/23/2024] [Indexed: 03/08/2024] Open
Abstract
OBJECTIVE To explore the predictive value of bedside lung ultrasound score in the severity of neonatal respiratory distress syndrome (NRDS) and mechanical ventilation and extubation. METHODS The clinical data of 65 neonates with NRDS and invasive mechanical ventilation diagnosed in the neonatal intensive care unit of our hospital from July 2021 to July 2022 were retrospectively analyzed. 65 neonates were included in the NRDS group, and 40 neonates with other common lung diseases were selected as the other lung disease groups. All neonates underwent lung ultrasound and X-ray examination. The correlation between lung ultrasound scores and arterial blood gas indexes was analyzed by Pearson. The efficacy of successful evacuation of mechanical ventilation was evaluated by lung ultrasound analysis by ROC curve analysis. RESULTS The positive rates of lung consolidation and white lung in NRDS group were higher than the other lung disease groups (P < 0.05). The positive rates of bronchial inflation sign and double lung points were lower than these in the other lung disease groups (P < 0.05). The ultrasound scores of both lungs, left lung, right lung, bilateral lung and double basal lung in the NRDS group were significantly higher than those in the other lung disease groups (P < 0.05). There was a significant positive correlation between lung ultrasound score and X-ray grade (r = 0.841, P < 0.001). The area under the curve (AUC) of lung ultrasound score for the differential diagnosis of NRDS and common lung diseases was 0.907. The AUC of lung ultrasound score in the differential diagnosis of mild and moderate, and moderate and severe NRDS were 0.914 and 0.933, respectively, which had high clinical value. The lung ultrasound score was positively correlated with the level of PaCO2 (r = 0.254, P = 0.041), and negatively correlated with the levels of SpO2 and PaO2 (r = - 0.459, - 0.362, P = 0.001, 0.003). The AUC of successful mechanical ventilation withdrawal predicted by the pulmonary ultrasound score before extubation was 0.954 (95% CI 0.907-1.000). The predictive value of successful extubation was 10 points of the pulmonary ultrasound score, with a sensitivity of 93.33% and a specificity of 88.00%. CONCLUSION The bedside lung ultrasound score can intuitively reflect the respiratory status of neonates, which provides clinicians with an important basis for disease evaluation.
Collapse
Affiliation(s)
- Peipei Huang
- Department of Ultrasound, The Third Affiliated Hospital of Shanghai University, Wenzhou People's Hospital, No. 299, Gu'an Road, Ouhai District, Wenzhou, 325000, Zhejiang, China
| | - Deng Chen
- Department of Ultrasound, The Third Affiliated Hospital of Shanghai University, Wenzhou People's Hospital, No. 299, Gu'an Road, Ouhai District, Wenzhou, 325000, Zhejiang, China.
| | - Xiuxiang Liu
- Department of Ultrasound, The Third Affiliated Hospital of Shanghai University, Wenzhou People's Hospital, No. 299, Gu'an Road, Ouhai District, Wenzhou, 325000, Zhejiang, China
| | - Xiang Zhang
- Department of Ultrasound, The Third Affiliated Hospital of Shanghai University, Wenzhou People's Hospital, No. 299, Gu'an Road, Ouhai District, Wenzhou, 325000, Zhejiang, China
| | - Xiazi Song
- Department of Neonatology, The Third Affiliated Hospital of Shanghai University, Wenzhou People's Hospital, Wenzhou, Zhejiang, China
| |
Collapse
|
3
|
Liu J. Ultrasound diagnosis and grading criteria of neonatal respiratory distress syndrome. J Matern Fetal Neonatal Med 2023; 36:2206943. [PMID: 37142428 DOI: 10.1080/14767058.2023.2206943] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Background: Respiratory distress syndrome (RDS) is a common critical lung disease in newborn infants, especially those in premature infants with higher mortality rate. Early and correct diagnosis is the key to improve its prognosis. Previously, the diagnosis of RDS mainly relied on chest X-ray (CXR) findings, and it has been graded into four stages based on the progression and severity of CXR changes. This traditional diagnosing and grading method may lead to high misdiagnosis rate or delayed diagnosis. Recently, using ultrasound to diagnose neonatal lung diseases and RDS is becoming increasingly popular, and the technology is gaining higher sensitivity and higher specificity. The management of RDS under lung ultrasound (LUS) monitoring has achieved significant results, reducing the misdiagnosis rate of RDS, thereby reducing the probability of mechanical ventilation and the use of exogenous pulmonary surfactant, and making the success rate of treatment of RDS up to 100%.Objective: The purpose of the article was to introduce the ultrasound grading methods and criteria of RDS, in order to promote the application of LUS in the diagnosis and treatment of RDS.Methods: Literature (in English and Chinese) on the use of ultrasound in the diagnosis of neonatal RDS between 2008 and 2022 was selected for inclusion in this study.Results: From the collected literature, the use of ultrasound in the diagnosis of RDS is increasing, and people's understanding of the ultrasound imaging findings of RDS is also changing. Among them, the research on ultrasound grading of RDS is the latest progress.Conclusion: Ultrasound is accurate and reliable in the diagnosis and differential diagnosis of RDS. It is of great clinical value to master the ultrasound diagnosis and grading criteria of RDS.
Collapse
Affiliation(s)
- Jing Liu
- Department of Neonatology and NICU, Beijing Chao-Yang Hospital, Capital Medical University, Beijing, China
| |
Collapse
|
4
|
Mohsen N, Solis-Garcia G, Jasani B, Nasef N, Mohamed A. Accuracy of lung ultrasound in predicting extubation failure in neonates: A systematic review and meta-analysis. Pediatr Pulmonol 2023; 58:2846-2856. [PMID: 37431954 DOI: 10.1002/ppul.26598] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2023] [Revised: 06/06/2023] [Accepted: 07/03/2023] [Indexed: 07/12/2023]
Abstract
OBJECTIVE To systematically review and meta-analyze the diagnostic accuracy of lung ultrasound score (LUS) in predicting extubation failure in neonates. STUDY DESIGN MEDLINE, COCHRANE, EMBASE, CINAHL, and clinicaltrials.gov were searched up to 30 November 2022, for studies evaluating the diagnostic accuracy of LUS in predicting extubation outcome in mechanically ventilated neonates. METHODOLOGY Two investigators independently assessed study eligibility, extracted data, and assessed study quality using the Quality Assessment for Studies of Diagnostic Accuracy 2 tool. We conducted a meta-analysis of pooled diagnostic accuracy data using random-effect models. Data were reported according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. We calculated pooled sensitivity and specificity, pooled diagnostic odds ratios with 95% confidence intervals (CI), and area under the curve (AUC). RESULTS Eight observational studies involving 564 neonates were included, and the risk of bias was low in seven studies. The pooled sensitivity and specificity for LUS in predicting extubation failure in neonates were 0.82 (95% CI: 0.75-0.88) and 0.83 (95% CI: 0.78-0.86), respectively. The pooled diagnostic odds ratio was 21.24 (95% CI: 10.45-43.19), and the AUC for LUS predicting extubation failure was 0.87 (95% CI: 0.80-0.95). Heterogeneity among included studies was low, both graphically and by statistical criteria (I2 = 7.35%, p = 0.37). CONCLUSIONS The predictive value of LUS in neonatal extubation failure may hold promise. However, given the current level of evidence and the methodological heterogeneity observed, there is a clear need for large-scale, well-designed prospective studies that establish standardized protocols for lung ultrasound performance and scoring. REGISTRATION The protocol was registered in OSF (https://doi.org/10.17605/OSF.IO/ZXQUT).
Collapse
Affiliation(s)
- Nada Mohsen
- Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Gonzalo Solis-Garcia
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Bonny Jasani
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- The Hospital for Sick Children, Toronto, Ontario, Canada
| | - Nehad Nasef
- Department of Pediatrics, Faculty of Medicine, Mansoura University, Mansoura, Egypt
| | - Adel Mohamed
- Department of Pediatrics, University of Toronto, Toronto, Ontario, Canada
- Mount Sinai Hospital, Toronto, Ontario, Canada
| |
Collapse
|
5
|
Luo K, Wang H, Huang F, Tang J. Optimal timing and cutoff range of lung ultrasound in predicting surfactant administration in neonates: A meta-analysis and systematic review. PLoS One 2023; 18:e0287758. [PMID: 37498845 PMCID: PMC10374100 DOI: 10.1371/journal.pone.0287758] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 06/11/2023] [Indexed: 07/29/2023] Open
Abstract
OBJECTIVE Timely application of surfactant replacement therapy is critical for neonates with respiratory distress syndrome (RDS). Presently, early clinical decision on surfactant use relies solely on ventilator parameters. However, ventilator parameters are unable to truly recapitulate the extent of surfactant deficiency. Lung ultrasound has been increasingly used in the early prediction of surfactant use in recent years, but its predictive value remains unclear. Therefore, we conducted this study to examine its predictive value in surfactant use and determine the optimal timing and cutoff value. METHODS Studies on neonates with respiratory distress or diagnosed with RDS were collected from PubMed, Embase, Cochrane Library, and Web of Science. Primary outcomes included sensitivity, specificity, and positive and negative predictive values of lung ultrasound. RESULTS Ten eligible studies with 1162 participants were included. The sensitivity and specificity of lung ultrasound in predicting surfactant use were 0.86 (95% CI: 0.81-0.90) and 0.82 (95% CI: 0.71-0.90), respectively. Lung ultrasound performed within 1-3 h after birth had a sensitivity of 0.89 (95% CI: 0.79-0.95) and a Youden's index of 0.67. Compared with a lung ultrasound score (LUS) cutoff of ≤6/7, ≤8, >5, >6/7, and >8, a LUS cutoff of ≤5 had higher Youden's index (0.73) and sensitivity (0.94, 95% CI: 0.85-0.97) in predicting surfactant use. CONCLUSIONS Lung ultrasound is effective for predicting surfactant use in neonates. Lung ultrasound within 1-3 h after birth and a LUS cutoff of 5 are recommended. However, the symptoms and oxygenation of the neonatal patients must also be considered.
Collapse
Affiliation(s)
- Keren Luo
- Department of Neonatology, West China Second Hospital, Sichuan University/Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu City, Sichuan Province, China
| | - Haoran Wang
- West China School of Medicine, Sichuan University, Chengdu City, Sichuan Province, China
| | - Fangjun Huang
- West China School of Medicine, Sichuan University, Chengdu City, Sichuan Province, China
| | - Jun Tang
- Department of Neonatology, West China Second Hospital, Sichuan University/Key Laboratory of Birth Defects and Related Diseases of Women and Children (Sichuan University), Ministry of Education, Chengdu City, Sichuan Province, China
| |
Collapse
|
6
|
Sorokine A, Czuzoj-Shulman N, Abenhaim HA. Maternal and neonatal outcomes in women with a history of chemotherapy exposure: a population-based study of 8 million obstetric admissions. Arch Gynecol Obstet 2023; 307:747-753. [PMID: 35523971 DOI: 10.1007/s00404-022-06566-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 03/23/2022] [Indexed: 11/30/2022]
Abstract
PURPOSE With improvement in cancer care and fertility preservation, increasing numbers of cancer survivors are requiring obstetrical care. The objective of our study was to evaluate the effect of history of chemotherapy exposure on maternal and neonatal outcomes. METHODS A retrospective population-based cohort study was conducted using the Healthcare Cost and Utilization Project-Nationwide Inpatient Sample (HCUP-NIS) to obtain data on maternal and newborn outcomes in a cohort of births occurring between the years 2006 and 2015. The annual and overall prevalence of chemotherapy exposure was calculated among pregnant women, and multivariate logistic regression models were used to estimate the effect of history of exposure to chemotherapy on the risk of adverse maternal and newborn outcomes. RESULTS Of 7,907,139 birth admissions, 613 had a history of chemotherapy exposure for an overall incidence of 7.75 per 100,000 admissions. The prevalence of chemotherapy exposure in pregnancy increased during the study period (P < 0.001). Women with a history of chemotherapy were more likely to suffer from obstetric and medical complications including pre-eclampsia, chorioamnionitis, postpartum hemorrhage, and venous thromboembolism as well as an increased risk in overall mortality (OR 9.39, 95% CI 1.31-67.32). No differences were observed in the incidence of adverse neonatal outcomes, including stillbirth, intra-uterine growth restriction, or preterm birth. CONCLUSION Women with history of chemotherapy have higher incidence of pregnancy complications and maternal death, with no differences in fetal or newborn outcomes.
Collapse
Affiliation(s)
- Avigayil Sorokine
- Department of Obstetrics and Gynecology, Jewish General Hospital, McGill University, Pavilion H, Room 325, 5790 Cote-des-Neiges Road, Montreal, H3S 1Y9, Canada
| | - Nicholas Czuzoj-Shulman
- Center for Clinical Epidemiology and Community Studies, Jewish General Hospital, Montreal, QC, Canada
| | - Haim Arie Abenhaim
- Department of Obstetrics and Gynecology, Jewish General Hospital, McGill University, Pavilion H, Room 325, 5790 Cote-des-Neiges Road, Montreal, H3S 1Y9, Canada.
- Center for Clinical Epidemiology and Community Studies, Jewish General Hospital, Montreal, QC, Canada.
| |
Collapse
|
7
|
Perri A, Fattore S, D’Andrea V, Sbordone A, Patti ML, Nobile S, Tirone C, Giordano L, Tana M, Priolo F, Serrao F, Riccardi R, Prontera G, Vento G. Lowering of the Neonatal Lung Ultrasonography Score after nCPAP Positioning in Neonates over 32 Weeks of Gestational Age with Neonatal Respiratory Distress. Diagnostics (Basel) 2022; 12:diagnostics12081909. [PMID: 36010259 PMCID: PMC9406690 DOI: 10.3390/diagnostics12081909] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Revised: 08/02/2022] [Accepted: 08/03/2022] [Indexed: 11/24/2022] Open
Abstract
Respiratory distress (RD) is one of the most common causes of admission to the neonatal intensive care unit. Correct diagnosis and timely intervention are crucial. Lung ultrasonography (LU) is a useful diagnostic tool for the neonatologist in the diagnosis of RD; the neonatal lung ultrasonography score (nLUS) can be used in the diagnostic process, but some authors hypothesise that it is also useful for the management of some neonatal RD. The aim of this study is to analyse the changes in nLUS score before (T0) and after (T1) the start of respiratory support with nasal CPAP in neonates over 32 weeks of age with RD. Thirty-three newborns were enrolled in this retrospective study. LU was performed before and after the start of CPAP. The median nLUS scores at T0 and T1 were 9 (IQR 7−12) and 7 (IQR 4−10), respectively, and showed a significant difference (p < 0.001). The magnitude of reduction in nLUS score, expressed as a percentage, was inversely related to the need for subsequent administration of exogenous surfactant. The study suggests the usefulness of the nLUS score in assessing the response to CPAP in neonates over 32 weeks gestational age.
Collapse
Affiliation(s)
- Alessandro Perri
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Simona Fattore
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Vito D’Andrea
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
- Correspondence: ; Tel.: +39-0630154357; Fax: +39-063383211
| | - Annamaria Sbordone
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Maria Letizia Patti
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Stefano Nobile
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Chiara Tirone
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Lucia Giordano
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Milena Tana
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Francesca Priolo
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Francesca Serrao
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Riccardo Riccardi
- Neonatal Intensive Care Unit, “San Giovanni Calibita Fatebenefratelli” Hospital, Isola Tiberina, 00186 Rome, Italy
| | - Giorgia Prontera
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| | - Giovanni Vento
- Department of Woman and Child Health and Public Health, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy
| |
Collapse
|
8
|
McGillick EV, te Pas AB, van den Akker T, Keus JMH, Thio M, Hooper SB. Evaluating Clinical Outcomes and Physiological Perspectives in Studies Investigating Respiratory Support for Babies Born at Term With or at Risk of Transient Tachypnea: A Narrative Review. Front Pediatr 2022; 10:878536. [PMID: 35813383 PMCID: PMC9260080 DOI: 10.3389/fped.2022.878536] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Accepted: 05/09/2022] [Indexed: 12/02/2022] Open
Abstract
Respiratory distress in the first few hours of life is a growing disease burden in otherwise healthy babies born at term (>37 weeks gestation). Babies born by cesarean section without labor (i.e., elective cesarean section) are at greater risk of developing respiratory distress due to elevated airway liquid volumes at birth. These babies are commonly diagnosed with transient tachypnea of the newborn (TTN) and historically treatments have mostly focused on enhancing airway liquid clearance pharmacologically or restricting fluid intake with limited success. Alternatively, a number of clinical studies have investigated the potential benefits of respiratory support in newborns with or at risk of TTN, but there is considerable heterogeneity in study designs and outcome measures. A literature search identified eight clinical studies investigating use of respiratory support on outcomes related to TTN in babies born at term. Study demographics including gestational age, mode of birth, antenatal corticosteroid exposure, TTN diagnosis, timing of intervention (prophylactic/interventional), respiratory support (type/interface/device/pressure), and study outcomes were compared. This narrative review provides an overview of factors within and between studies assessing respiratory support for preventing and/or treating TTN. In addition, we discuss the physiological understanding of how respiratory support aids lung function in newborns with elevated airway liquid volumes at birth. However, many questions remain regarding the timing of onset, pressure delivered, device/interface used and duration, and weaning of support. Future studies are required to address these gaps in knowledge to provide evidenced based recommendations for management of newborns with or at risk of TTN.
Collapse
Affiliation(s)
- Erin V. McGillick
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| | - Arjan B. te Pas
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, Netherlands
| | - Thomas van den Akker
- Department of Obstetrics and Gynaecology, Leiden University Medical Center, Leiden, Netherlands
- Athena Institute, Vrije Universiteit Amsterdam, Amsterdam, Netherlands
| | - J. M. H. Keus
- Division of Neonatology, Department of Pediatrics, Leiden University Medical Center, Leiden, Netherlands
| | - Marta Thio
- Newborn Research, The Royal Women’s Hospital, Melbourne, VIC, Australia
- The Murdoch Children’s Research Institute, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, University of Melbourne, Melbourne, VIC, Australia
| | - Stuart B. Hooper
- The Ritchie Centre, Hudson Institute of Medical Research, Melbourne, VIC, Australia
- Department of Obstetrics and Gynaecology, Monash University, Melbourne, VIC, Australia
| |
Collapse
|
9
|
Zong H, Huang Z, Zhao J, Lin B, Fu Y, Lin Y, Huang P, Sun H, Yang C. The Value of Lung Ultrasound Score in Neonatology. Front Pediatr 2022; 10:791664. [PMID: 35633958 PMCID: PMC9130655 DOI: 10.3389/fped.2022.791664] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Accepted: 04/20/2022] [Indexed: 12/11/2022] Open
Abstract
Point-of-care lung ultrasound (LUS) is increasingly applied in the neonatal intensive care unit (NICU). Diagnostic applications for LUS in the NICU contain the diagnosis of many common neonatal pulmonary diseases (such as Respiratory distress syndrome, Transient tachypnea of the newborn, Meconium aspiration syndrome, Pneumonia, Pneumothorax, and Pleural effusion) which have been validated. In addition to being employed as a diagnostic tool in the classical sense of the term, recent studies have shown that the number and type of artifacts are associated with lung aeration. Based on this theory, over the last few years, LUS has also been used as a semi-quantitative method or as a "functional" tool. Scores have been proposed to monitor the progress of neonatal lung diseases and to decide whether or not to perform a specific treatment. The semi-quantitative LUS scores (LUSs) have been developed to predict the demand for surfactant therapy, the need of respiratory support and the progress of bronchopulmonary dysplasia. Given their ease of use, accuracy and lack of invasiveness, the use of LUSs is increasing in clinical practice. Therefore, this manuscript will review the application of LUSs in neonatal lung diseases.
Collapse
Affiliation(s)
- Haifeng Zong
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Zhifeng Huang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Jie Zhao
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Bingchun Lin
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Yongping Fu
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Yanqing Lin
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Peng Huang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Hongyan Sun
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| | - Chuanzhong Yang
- Neonatal Intensive Care Unit, Affiliated Shenzhen Maternity & Child Healthcare Hospital, Southern Medical University, Shenzhen, China
| |
Collapse
|
10
|
Madajczak D, Daboval T, Lauterbach R, Łoniewska B, Błaż W, Szczapa T, Sadowska-Krawczenko I, Michalak-Kloc M, Sławska H, Borszewska-Kornacka M, Bokiniec R. Protocol for a multicenter, double-blind, randomized, placebo-controlled phase III trial of the inhaled β2-adrenergic receptor agonist salbutamol for transient tachypnea of the newborn (the REFSAL trial). Front Pediatr 2022; 10:1060843. [PMID: 36714639 PMCID: PMC9879660 DOI: 10.3389/fped.2022.1060843] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Accepted: 12/20/2022] [Indexed: 01/14/2023] Open
Abstract
BACKGROUND Transient tachypnea of the newborn (TTN), which results from inadequate absorption of fetal lung fluid, is the most common cause of neonatal respiratory distress. Stimulation of β-adrenergic receptors enhances alveolar fluid absorption. Therefore, the β2-adrenergic receptor agonist salbutamol has been proposed as a treatment for TTN. This study aims to evaluate the efficacy and safety of salbutamol as supportive pharmacotherapy together with non-invasive nasal continuous positive airway pressure (NIV/nCPAP) for the prevention of persistent pulmonary hypertension of the newborn (PPHN) in infants with TTN. METHODS AND ANALYSIS This multicenter, double-blind, phase III trial will include infants with a gestational age between 32 and 42 weeks who are affected by respiratory disorders and treated in eight neonatal intensive care units in Poland. A total of 608 infants within 24 h after birth will be enrolled and randomly assigned (1:1) to receive nebulized salbutamol with NIV or placebo (nebulized 0.9% NaCl) with NIV. The primary outcome is the percentage of infants with TTN who develop PPHN. The secondary outcomes are the severity of respiratory distress (assessed with the modified TTN Silverman score), frequency of need for intubation, duration of NIV and hospitalization, acid-base balance (blood pH, partial pressure of O2 and CO2, and base excess), and blood serum ionogram for Na+, K+, and Ca2+. DISCUSSION The Respiratory Failure with Salbutamol (REFSAL) study will be the first clinical trial to evaluate the efficacy and safety of salbutamol in the prevention of persistent pulmonary hypertension in newborns with tachypnea, and will improve short term outcomes. If successful, the study will demonstrate the feasibility of early intervention with NIV/nCPAP together with nebulized salbutamol in the management of TTN. ETHICS AND DISSEMINATION The study protocol was approved by the Bioethics Committee of the Medical University of Warsaw, Warsaw, Poland on November 16, 2020 (decision number KB/190/2020). All procedures will follow the principles of the Declaration of Helsinki. The results of the study will be submitted for knowledge translation in peer-reviewed journals and presented at national and international pediatric society conferences. CLINICAL TRIAL REGISTRATION It is registered at ClinicalTrials.gov NCT05527704, EudraCT 2020-003913-36; Protocol version 5.0 from 04/01/2022.
Collapse
Affiliation(s)
- Dariusz Madajczak
- Department of Neonatology and Neonatal Intensive Care, Medical University of Warsaw, Warsaw, Poland
| | - Thierry Daboval
- Department of Pediatrics - Division of Neonatology, Faculty of Medicine, University of Ottawa, Ottawa, ON, Canada
| | | | - Beata Łoniewska
- Department of Neonatology and Intensive Neonatal Care, Pomeranian Medical University, Szczecin, Poland
| | - Witold Błaż
- Clinical Department of Neonatology With Neonatal Intensive Care Unit, University of Rzeszow, Saint Jadwiga the Queen Clinical Provincial Hospital No 2, Rzeszow, Poland
| | - Tomasz Szczapa
- Department of Neonatology, Poznań University of Medical Sciences, Poznań, Poland
| | - Iwona Sadowska-Krawczenko
- Department of Neonatology, Collegium Medicum in Bydgoszcz, Nicolaus Copernicus University, Toruń, Poland
| | - Marzena Michalak-Kloc
- Neonatology Clinical Department, Karol Marcinkowski University Hospital, Zielona Góra, Poland
| | - Helena Sławska
- Neonatology Unit, Specialist Hospital No 2, Bytom, Medical University of Silesia, Bytom, Poland
| | | | - Renata Bokiniec
- Department of Neonatology and Neonatal Intensive Care, Medical University of Warsaw, Warsaw, Poland
| | | |
Collapse
|
11
|
Wang J, Wei H, Chen H, Wan K, Mao R, Xiao P, Chang X. Application of ultrasonography in neonatal lung disease: An updated review. Front Pediatr 2022; 10:1020437. [PMID: 36389379 PMCID: PMC9640768 DOI: 10.3389/fped.2022.1020437] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 09/27/2022] [Indexed: 11/26/2022] Open
Abstract
Lung disease is often life-threatening for both preterm and term newborns. Therefore, an accurate and rapid diagnosis of lung diseases in newborns is crucial, as management strategies differ with different etiologies. To reduce the risk of radiation exposure derived from the conventionally used chest x-ray as well as computed tomography scans, lung ultrasonography (LUS) has been introduced in clinical practice to identify and differentiate neonatal lung diseases because of its radiation-free characteristic, convenience, high accuracy, and low cost. In recent years, it has been proved that LUS exhibits high sensitivity and specificity for identifying various neonatal lung diseases. Here, we offer an updated review of the applications of LUS in neonatal lung diseases based on the reports published in recent years (2017 to present).
Collapse
Affiliation(s)
- Jin Wang
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Hongjuan Wei
- Department of Neonatology, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Hui Chen
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Ke Wan
- School of Medical Sciences, University of Sydney, Sydney, New South Wales, Australia
| | - Ruifeng Mao
- School of Life Sciences, Huaiyin Normal University, Huai'an, China
| | - Peng Xiao
- Department of Dermatology, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| | - Xin Chang
- Department of Ultrasound Medicine, Nanjing Lishui People's Hospital, Zhongda Hospital Lishui Branch, Southeast University, Nanjing, China
| |
Collapse
|