1
|
Bourguignon N, Karp P, Attallah C, Chamorro DA, Oggero M, Booth R, Ferrero S, Bhansali S, Pérez MS, Lerner B, Helguera G. Large Area Microfluidic Bioreactor for Production of Recombinant Protein. BIOSENSORS 2022; 12:bios12070526. [PMID: 35884329 PMCID: PMC9313365 DOI: 10.3390/bios12070526] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Revised: 07/06/2022] [Accepted: 07/07/2022] [Indexed: 11/16/2022]
Abstract
To produce innovative biopharmaceuticals, highly flexible, adaptable, robust, and affordable bioprocess platforms for bioreactors are essential. In this article, we describe the development of a large-area microfluidic bioreactor (LM bioreactor) for mammalian cell culture that works at laminar flow and perfusion conditions. The 184 cm2 32 cisterns LM bioreactor is the largest polydimethylsiloxane (PDMS) microfluidic device fabricated by photopolymer flexographic master mold methodology, reaching a final volume of 2.8 mL. The LM bioreactor was connected to a syringe pump system for culture media perfusion, and the cells’ culture was monitored by photomicrograph imaging. CHO-ahIFN-α2b adherent cell line expressing the anti-hIFN-a2b recombinant scFv-Fc monoclonal antibody (mAb) for the treatment of systemic lupus erythematosus were cultured on the LM bioreactor. Cell culture and mAb production in the LM bioreactor could be sustained for 18 days. Moreover, the anti-hIFN-a2b produced in the LM bioreactor showed higher affinity and neutralizing antiproliferative activity compared to those mAbs produced in the control condition. We demonstrate for the first-time, a large area microfluidic bioreactor for mammalian cell culture that enables a controlled microenvironment suitable for the development of high-quality biologics with potential for therapeutic use.
Collapse
Affiliation(s)
- Natalia Bourguignon
- Centro IREN, Universidad Tecnológica Nacional, Haedo B1706EAH, Provincia de Buenos Aires, Argentina; (N.B.); (D.A.C.); (M.S.P.)
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL 33174, USA;
| | - Paola Karp
- Laboratorio de Biotecnología Farmacéutica, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Ciudad de Buenos Aires C1428ADN, Argentina; (P.K.); (S.F.)
| | - Carolina Attallah
- Centro Biotecnológico del Litoral, Laboratorio de Cultivos Celulares, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral (UNL), CONICET, Santa Fe S3000ZAA, Provincia de Santa Fe, Argentina; (C.A.); (M.O.)
| | - Daniel A. Chamorro
- Centro IREN, Universidad Tecnológica Nacional, Haedo B1706EAH, Provincia de Buenos Aires, Argentina; (N.B.); (D.A.C.); (M.S.P.)
| | - Marcos Oggero
- Centro Biotecnológico del Litoral, Laboratorio de Cultivos Celulares, Facultad de Bioquímica y Ciencias Biológicas, Universidad Nacional del Litoral (UNL), CONICET, Santa Fe S3000ZAA, Provincia de Santa Fe, Argentina; (C.A.); (M.O.)
| | - Ross Booth
- Roche Sequencing Solutions, Inc., Pleasanton, CA 94588, USA;
| | - Sol Ferrero
- Laboratorio de Biotecnología Farmacéutica, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Ciudad de Buenos Aires C1428ADN, Argentina; (P.K.); (S.F.)
| | - Shekhar Bhansali
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL 33174, USA;
| | - Maximiliano S. Pérez
- Centro IREN, Universidad Tecnológica Nacional, Haedo B1706EAH, Provincia de Buenos Aires, Argentina; (N.B.); (D.A.C.); (M.S.P.)
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL 33174, USA;
| | - Betiana Lerner
- Centro IREN, Universidad Tecnológica Nacional, Haedo B1706EAH, Provincia de Buenos Aires, Argentina; (N.B.); (D.A.C.); (M.S.P.)
- Department of Electrical and Computer Engineering, Florida International University, Miami, FL 33174, USA;
- Correspondence: (B.L.); (G.H.); Tel.:+5411-4343-1177 (ext. 1209) (B.L.); +54-11-4783-2869 (G.H.)
| | - Gustavo Helguera
- Laboratorio de Biotecnología Farmacéutica, Instituto de Biología y Medicina Experimental (IBYME-CONICET), Ciudad de Buenos Aires C1428ADN, Argentina; (P.K.); (S.F.)
- Correspondence: (B.L.); (G.H.); Tel.:+5411-4343-1177 (ext. 1209) (B.L.); +54-11-4783-2869 (G.H.)
| |
Collapse
|
2
|
Taylor DP, Mathur P, Renaud P, Kaigala GV. Microscale hydrodynamic confinements: shaping liquids across length scales as a toolbox in life sciences. LAB ON A CHIP 2022; 22:1415-1437. [PMID: 35348555 DOI: 10.1039/d1lc01101d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Hydrodynamic phenomena can be leveraged to confine a range of biological and chemical species without needing physical walls. In this review, we list methods for the generation and manipulation of microfluidic hydrodynamic confinements in free-flowing liquids and near surfaces, and elucidate the associated underlying theory and discuss their utility in the emerging area of open space microfluidics applied to life-sciences. Microscale hydrodynamic confinements are already starting to transform approaches in fundamental and applied life-sciences research from precise separation and sorting of individual cells, allowing localized bio-printing to multiplexing for clinical diagnosis. Through the choice of specific flow regimes and geometrical boundary conditions, hydrodynamic confinements can confine species across different length scales from small molecules to large cells, and thus be applied to a wide range of functionalities. We here provide practical examples and implementations for the formation of these confinements in different boundary conditions - within closed channels, in between parallel plates and in an open liquid volume. Further, to enable non-microfluidics researchers to apply hydrodynamic flow confinements in their work, we provide simplified instructions pertaining to their design and modelling, as well as to the formation of hydrodynamic flow confinements in the form of step-by-step tutorials and analytical toolbox software. This review is written with the idea to lower the barrier towards the use of hydrodynamic flow confinements in life sciences research.
Collapse
Affiliation(s)
- David P Taylor
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
- Microsystems Laboratory 4, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Prerit Mathur
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
- Dept. of Chemistry and Applied Biosciences, Eidgenössische Technische Hochschule (ETH), Vladimir-Prelog-Weg 1-5/10, 8093 Zurich, Switzerland
| | - Philippe Renaud
- Microsystems Laboratory 4, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland
| | - Govind V Kaigala
- IBM Research - Europe, Säumerstrasse 4, 8803 Rüschlikon, Switzerland.
| |
Collapse
|
3
|
Ostrikov K, Kashani MN, Vasilev K, MacGregor MN. Fluid Flow Dependency in Immunoselective Cell Capture via Liquid Biopsy. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:12388-12396. [PMID: 34596407 DOI: 10.1021/acs.langmuir.1c01998] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
Liquid biopsy targets rare cells that overexpress disease-specific membrane markers and capture these cells via immunoaffinity. The diagnosis efficiency of liquid biopsy can be impaired by the presence of healthy adherent cells also expressing the same biomarkers. Here, we investigated the effect of settling times and rinsing flow rates on the efficiency of EpCAM-based immunocapture using both simulation and experiments with three different cell types. Cell-surface adhesion forces and shear rates were calculated to define the range of rinsing flow rates to test experimentally. Healthy adherent cells did not adhere to blocked immunofunctionalized surfaces within the timeframe of the experiment; however, healthy EpCAM positive cells did bind to the surface to some extent. The greatest difference in capture efficiency was obtained using a high rinsing flow rate of 25 mL/min following 40 min static incubation, indicating that optimizing rinsing flow rates could be a viable option to capture, more specifically, cancer cells overexpressing EpCAM.
Collapse
Affiliation(s)
- Kola Ostrikov
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
| | - Moein Navvab Kashani
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
- South Australian Node of the Australian National Fabrication Facility, Mawson Lakes 5095, Australia
| | - Krasimir Vasilev
- UniSA STEM, University of South Australia, Mawson Lakes 5095, Australia
| | | |
Collapse
|
4
|
Abstract
![]()
Hydrodynamic phenomena
are ubiquitous in living organisms and can
be used to manipulate cells or emulate physiological microenvironments
experienced in vivo. Hydrodynamic effects influence multiple cellular
properties and processes, including cell morphology, intracellular
processes, cell–cell signaling cascades and reaction kinetics,
and play an important role at the single-cell, multicellular, and
organ level. Selected hydrodynamic effects can also be leveraged to
control mechanical stresses, analyte transport, as well as local temperature
within cellular microenvironments. With a better understanding of
fluid mechanics at the micrometer-length scale and the advent of microfluidic
technologies, a new generation of experimental tools that provide
control over cellular microenvironments and emulate physiological
conditions with exquisite accuracy is now emerging. Accordingly, we
believe that it is timely to assess the concepts underlying hydrodynamic
control of cellular microenvironments and their applications and provide
some perspective on the future of such tools in in vitro cell-culture
models. Generally, we describe the interplay between living cells,
hydrodynamic stressors, and fluid flow-induced effects imposed on
the cells. This interplay results in a broad range of chemical, biological,
and physical phenomena in and around cells. More specifically, we
describe and formulate the underlying physics of hydrodynamic phenomena
affecting both adhered and suspended cells. Moreover, we provide an
overview of representative studies that leverage hydrodynamic effects
in the context of single-cell studies within microfluidic systems.
Collapse
Affiliation(s)
- Deborah Huber
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland.,Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Ali Oskooei
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| | - Xavier Casadevall I Solvas
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Andrew deMello
- Institute of Chemical and Bioengineering, Department of Chemistry and Applied Biosciences, ETH Zürich , Vladimir-Prelog-Weg 1, 8093 Zürich, Switzerland
| | - Govind V Kaigala
- IBM Research-Zürich , Säumerstrasse 4, 8803 Rüschlikon, Switzerland
| |
Collapse
|
5
|
Abstract
Cells employing amoeboid motility exhibit repetitive cycles of rapid expansion and contraction and apply coordinated traction forces to their environment. Although aspects of this process are well studied, it is unclear how the cell controls the coordination of cell length changes with adhesion to the surface. Here, we develop a simple model to mechanistically explain the emergence of periodic changes in length and spatiotemporal dynamics of traction forces measured in chemotaxing unicellular amoeba, Dictyostelium discoideum. In contrast to the biochemical mechanisms that have been implicated in the coordination of some cellular processes, we show that many features of amoeboid locomotion emerge from a simple mechanochemical model. The mechanism for interaction with the environment in Dictyostelium is unknown and thus, we explore different cell-environment interaction models to reveal that mechanosensitive adhesions are necessary to reproduce the spatiotemporal adhesion patterns. In this modeling framework, we find that the other motility modes, such as smooth gliding, arise naturally with variations in the physical properties of the surface. Thus, our work highlights the prominent role of biomechanics in determining the emergent features of amoeboid locomotion.
Collapse
|
6
|
The Expression of HMGB1 in Bone Marrow MSCs Is Upregulated by Hypoxia with Regulatory Effects on the Apoptosis and Adhesion. BIOMED RESEARCH INTERNATIONAL 2016; 2016:4598927. [PMID: 28050559 PMCID: PMC5168487 DOI: 10.1155/2016/4598927] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/14/2016] [Revised: 09/24/2016] [Accepted: 10/13/2016] [Indexed: 02/05/2023]
Abstract
Background and Aims. Hypoxia regulates the survival of mesenchymal stem cells (MSCs) but the mechanism is unclear. In hypoxia, the level of high mobility group box 1 (HMGB1) was increased in many cells which may be involved in the regulation of cell biology. The aim is to determine whether hypoxia affects the expression of HMGB1 in bone marrow MSCs (BM-MSCs) and to investigate the role of HMGB1 in the apoptosis and adhesion. Methods. BM-MSCs were exposed to hypoxia (1% O2) and normoxia (20% O2) and the expression of HMGB1 was measured by RT-PCR and western blotting. The apoptosis and adhesion of BM-MSCs were evaluated after interfered by different concentrations of HMGB1. Results. Expression of HMGB1 in BM-MSCs showed a significant upregulation in hypoxia when compared to those in normoxia. The adhesion of BM-MSCs was increased by HMGB1 in a concentration-dependent manner; the apoptosis effect of HMGB1 depended on its concentrations: HMGB1 at low concentration (50 ng/mL) promoted the apoptosis of BM-MSCs while HMGB1 at high concentration (≥100 ng/mL) reduced this apoptosis. Conclusions. Hypoxia enhanced the expression of HMGB1 in BM-MSCs with influences on apoptosis and adhesion and this could have a significant effect on the regenerative potential of MSC-based strategies.
Collapse
|
7
|
Zhu X, Bouffanais R, Yue DKP. Interplay between motility and cell-substratum adhesion in amoeboid cells. BIOMICROFLUIDICS 2015; 9:054112. [PMID: 26487898 PMCID: PMC4592429 DOI: 10.1063/1.4931762] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2015] [Accepted: 09/15/2015] [Indexed: 05/07/2023]
Abstract
The effective migration of amoeboid cells requires a fine regulation of cell-substratum adhesion. These entwined processes have been shown to be regulated by a host of biophysical and biochemical cues. Here, we reveal the pivotal role played by calcium-based mechanosensation in the active regulation of adhesion resulting in a high migratory adaptability. Using mechanotactically driven Dictyostelium discoideum amoebae, we uncover the existence of optimal mechanosensitive conditions-corresponding to specific levels of extracellular calcium-for persistent directional migration over physicochemically different substrates. When these optimal mechanosensitive conditions are met, noticeable enhancement in cell migration directionality and speed is achieved, yet with significant differences among the different substrates. In the same narrow range of calcium concentrations that yields optimal cellular mechanosensory activity, we uncovered an absolute minimum in cell-substratum adhesion activity, for all considered substrates, with differences in adhesion strength among them amplified. The blocking of the mechanosensitive ion channels with gadolinium-i.e., the inhibition of the primary mechanosensory apparatus-hampers the active reduction in substrate adhesion, thereby leading to the same undifferentiated and drastically reduced directed migratory response. The adaptive behavioral responses of Dictyostelium cells sensitive to substrates with varying physicochemical properties suggest the possibility of novel surface analyses based on the mechanobiological ability of mechanosensitive and guidable cells to probe substrates at the nanometer-to-micrometer level.
Collapse
Affiliation(s)
- Xiaoying Zhu
- Singapore University of Technology and Design , 8 Somapah Road, Singapore 487372
| | - Roland Bouffanais
- Singapore University of Technology and Design , 8 Somapah Road, Singapore 487372
| | - Dick K P Yue
- Massachusetts Institute of Technology , 77 Massachusetts Avenue, Cambridge, Massachusetts 02139, USA
| |
Collapse
|