1
|
Fratta G, Daniele P, Labanca I, Acconcia G, Rech I. Near-zero distortion in TCSPC at more than one photon per excitation period: experimental validation. OPTICS LETTERS 2024; 49:4958-4961. [PMID: 39208005 DOI: 10.1364/ol.534363] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Accepted: 08/13/2024] [Indexed: 09/04/2024]
Abstract
The time-correlated single-photon counting (TCSPC) technique is widely renowned for its capability of reconstructing rapid and weak light signals with exceptional sensitivity and sub-picosecond timing resolution. Unfortunately, the speed of TCSPC has been historically severely limited to avoid a phenomenon known as pileup distortion. For this reason, the count rate of a classic TCSPC acquisition channel is kept below a few percent of the laser excitation rate (usually 1%-5%). In this work, we experimentally validate a novel, to our knowledge, TCSPC theory recently reported that effectively overcomes such a limitation and finally achieves high-speed operation without distortion. Exploiting a single-photon avalanche diode (SPAD), in this paper we show how to acquire additional information about the status of the system at run time, and by combining it with the classic TCSPC data histogram, we report how a count rate of approximately 60% of the excitation frequency with near-zero distortion can indeed be achieved with a commercial system.
Collapse
|
2
|
Pullano SA, Oliva G, Titirsha T, Shuvo MMH, Islam SK, Laganà F, La Gatta A, Fiorillo AS. Design of an Electronic Interface for Single-Photon Avalanche Diodes. SENSORS (BASEL, SWITZERLAND) 2024; 24:5568. [PMID: 39275479 PMCID: PMC11398220 DOI: 10.3390/s24175568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 08/26/2024] [Accepted: 08/27/2024] [Indexed: 09/16/2024]
Abstract
Single-photon avalanche diodes (SPADs) belong to a family of avalanche photodiodes (APDs) with single-photon detection capability that operate above the breakdown voltage (i.e., Geiger mode). Design and technology constraints, such as dark current, photon detection probability, and power dissipation, impose inherent device limitations on avalanche photodiodes. Moreover, after the detection of a photon, SPADs require dead time for avalanche quenching and recharge before they can detect another photon. The reduction in dead time results in higher efficiency for photon detection in high-frequency applications. In this work, an electronic interface, based on the pole-zero compensation technique for reducing dead time, was investigated. A nanosecond pulse generator was designed and fabricated to generate pulses of comparable voltage to an avalanche transistor. The quenching time constant (τq) is not affected by the compensation capacitance variation, while an increase of about 30% in the τq is related to the properties of the specific op-amp used in the design. Conversely, the recovery time was observed to be strongly influenced by the compensation capacitance. Reductions in the recovery time, from 927.3 ns down to 57.6 ns and 9.8 ns, were observed when varying the compensation capacitance in the range of 5-0.1 pF. The experimental results from an SPAD combined with an electronic interface based on an avalanche transistor are in strong accordance, providing similar output pulses to those of an illuminated SPAD.
Collapse
Affiliation(s)
- Salvatore A Pullano
- Department of Health Sciences, "Magna Graecia" University, 88100 Catanzaro, Italy
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA
| | - Giuseppe Oliva
- Department of Health Sciences, "Magna Graecia" University, 88100 Catanzaro, Italy
| | - Twisha Titirsha
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA
| | - Md Maruf Hossain Shuvo
- Department of Electrical and Computer Engineering, University of Texas at El Paso, El Paso, TX 79968, USA
| | - Syed Kamrul Islam
- Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO 65211, USA
| | - Filippo Laganà
- Department of Health Sciences, "Magna Graecia" University, 88100 Catanzaro, Italy
| | - Antonio La Gatta
- Department of Health Sciences, "Magna Graecia" University, 88100 Catanzaro, Italy
| | - Antonino S Fiorillo
- Department of Health Sciences, "Magna Graecia" University, 88100 Catanzaro, Italy
| |
Collapse
|
3
|
Bovolenta A, Cominelli A, Acconcia G, Rech I. Quantifying distortion in time-correlated single photon counting: a universal parameter. OPTICS LETTERS 2024; 49:1563-1566. [PMID: 38489451 DOI: 10.1364/ol.511914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Accepted: 02/22/2024] [Indexed: 03/17/2024]
Abstract
One major drawback of the classic time-correlated single photon counting (TCSPC) technique is pileup-related distortion. To keep it under a reasonable level, the maximum count rate has to be reduced, posing a serious limitation to the overall measurement speed. This means that there is an intrinsic trade-off between speed and distortion: either count rate is raised, but distortion is worsened, or distortion is minimized at the expense of speed. In both cases, it is impossible to precisely evaluate the degree of distortion introduced. Here comes our new, to the best of our knowledge, figure of merit, which is able to provide a numerical estimate of the distortion whatever the signal shape is, marking a real turning point in the way of doing TCSPC. In this article, this new parameter will be defined and its effectiveness will be demonstrated by means of mathematical computations.
Collapse
|
4
|
Acconcia G, Ceccarelli F, Gulinatti A, Rech I. Timing measurements with silicon single photon avalanche diodes: principles and perspectives [Invited]. OPTICS EXPRESS 2023; 31:33963-33999. [PMID: 37859164 DOI: 10.1364/oe.491400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/22/2023] [Accepted: 09/10/2023] [Indexed: 10/21/2023]
Abstract
Picosecond timing of single photons has laid the foundation of a great variety of applications, from life sciences to quantum communication, thanks to the combination of ultimate sensitivity with a bandwidth that cannot be reached by analog recording techniques. Nowadays, more and more applications could still be enabled or advanced by progress in the available instrumentation, resulting in a steadily increasing research interest in this field. In this scenario, single-photon avalanche diodes (SPADs) have gained a key position, thanks to the remarkable precision they are able to provide, along with other key advantages like ruggedness, compactness, large signal amplitude, and room temperature operation, which neatly distinguish them from other solutions like superconducting nanowire single-photon detectors and silicon photomultipliers. With this work, we aim at filling a gap in the literature by providing a thorough discussion of the main design rules and tradeoffs for silicon SPADs and the electronics employed along them to achieve high timing precision. In the end, we conclude with our outlook on the future by summarizing new routes that could benefit from present and prospective timing features of silicon SPADs.
Collapse
|
5
|
Chen P, Kang Q, Niu J, Jing Y, Zhang X, Yu B, Qu J, Lin D. Fluorescence lifetime tracking and imaging of single moving particles assisted by a low-photon-count analysis algorithm. BIOMEDICAL OPTICS EXPRESS 2023; 14:1718-1731. [PMID: 37078048 PMCID: PMC10110318 DOI: 10.1364/boe.485729] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/17/2023] [Revised: 03/06/2023] [Accepted: 03/06/2023] [Indexed: 05/03/2023]
Abstract
Fluorescence lifetime imaging microscopy (FLIM) has been widely used in the field of biological research because of its high specificity, sensitivity, and quantitative ability in the sensing cellular microenvironment. The most commonly used FLIM technology is based on time-correlated single photon counting (TCSPC). Although the TCSPC method has the highest temporal resolution, the data acquisition time is usually long, and the imaging speed is slow. In this work, we proposed a fast FLIM technology for fluorescence lifetime tracking and imaging of single moving particles, named single particle tracking FLIM (SPT-FLIM). We used feedback-controlled addressing scanning and Mosaic FLIM mode imaging to reduce the number of scanned pixels and the data readout time, respectively. Moreover, we developed a compressed sensing analysis algorithm based on alternating descent conditional gradient (ADCG) for low-photon-count data. We applied the ADCG-FLIM algorithm on both simulated and experimental datasets to evaluate its performance. The results showed that ADCG-FLIM could achieve reliable lifetime estimation with high accuracy and precision in the case of a photon count less than 100. By reducing the photon count requirement for each pixel from, typically, 1000 to 100, the acquisition time for a single frame lifetime image could be significantly shortened, and the imaging speed could be improved to a great extent. On this basis, we obtained lifetime trajectories of moving fluorescent beads using the SPT-FLIM technique. Overall, our work offers a powerful tool for fluorescence lifetime tracking and imaging of single moving particles, which will promote the application of TCSPC-FLIM in biological research.
Collapse
|
6
|
Avanzi E, Behera A, Contini D, Spinelli L, Dalla Mora A, Di Sieno L. Effects and correctability of pile-up distortion using established figures of merit in time-domain diffuse optics at extreme photon rates. Sci Rep 2022; 12:5417. [PMID: 35354888 PMCID: PMC8967884 DOI: 10.1038/s41598-022-09385-5] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Accepted: 03/22/2022] [Indexed: 11/09/2022] Open
Abstract
Time-domain diffuse optics (TD-DO) allows one to probe diffusive media with recognized advantages over other working domains but suffers from a poor signal-to-noise ratio (SNR) resulting from the need to build-up the histogram of single-photon arrival times with maximum count rates (CR) of few percent of the laser pulse rate to avoid the so-called "pile-up" distortion. Here we explore the feasibility of TD-DO under severe pile-up conditions with a systematic in-silico/experimental study evaluating the effects and correctability of the distortion by means of shared figures of merit. In-silico, we demonstrate that pile-up correction allows one the retrieval of homogeneous optical properties with average error < 1% up to a CR > 99%, while the optimal CR needed to detect localized perturbation was found to be 83%. Experiments reported here confirm these findings despite exhibiting higher accuracy errors in the retrieval of homogeneous optical properties and higher noise in the detection of localized absorption perturbations, but in line with the state-of-the-art systems. This work validates a new working regime for TD-DO, demonstrating an increase of the SNR at constant acquisition time, but also potentially leading in the future to previously unrealizable measurements of dynamic phenomena or in spatial scanning applications.
Collapse
Affiliation(s)
- Elisabetta Avanzi
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy
| | - Anurag Behera
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy
| | - Davide Contini
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy
| | - Lorenzo Spinelli
- Istituto di Fotonica e Nanotecnologie, Consiglio Nazionale delle Ricerche, Piazza Leonardo da Vinci 32, 20133, Milan, Italy
| | - Alberto Dalla Mora
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy.
| | - Laura Di Sieno
- Dipartimento di Fisica, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133, Milan, Italy
| |
Collapse
|
7
|
Farina S, Labanca I, Acconcia G, Ghezzi A, Farina A, D'Andrea C, Rech I. Above pile-up fluorescence microscopy with a 32 Mc/s single-channel time-resolved SPAD system. OPTICS LETTERS 2022; 47:82-85. [PMID: 34951886 DOI: 10.1364/ol.444815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 11/15/2021] [Indexed: 06/14/2023]
Abstract
One of the major drawbacks of time-correlated single-photon counting (TCSPC) is generally represented by pile-up distortion, which strongly bounds the maximum acquisition speed to a few percent of the laser excitation rate. Based on a previous theoretical analysis, recently we presented the first, to the best of our knowledge, low-distortion and high-speed TCSPC system capable of overcoming the pile-up limitation by perfectly matching the single-photon avalanche diode (SPAD) dead time to the laser period. In this work, we validate the proposed system in a standard fluorescence measurement by comparing experimental data with the reference theoretical framework. As a result, a count rate of 32 Mc/s was achieved with a single-channel system still observing a negligible lifetime distortion.
Collapse
|
8
|
Farina S, Acconcia G, Labanca I, Ghioni M, Rech I. Toward ultra-fast time-correlated single-photon counting: A compact module to surpass the pile-up limit. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:063702. [PMID: 34243546 DOI: 10.1063/5.0044774] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Accepted: 05/28/2021] [Indexed: 06/13/2023]
Abstract
Time-Correlated Single-Photon Counting (TCSPC) is an excellent technique used in a great variety of scientific experiments to acquire exceptionally fast and faint light signals. Above all, in Fluorescence Lifetime Imaging (FLIM), it is widely recognized as the gold standard to record sub-nanosecond transient phenomena with picosecond precision. Unfortunately, TCSPC has an intrinsic limitation: to avoid the so-called pile-up distortion, the experiments have been historically carried out, limiting the acquisition rate below 5% of the excitation frequency. In 2017, we demonstrated that such a limitation can be overcome if the detector dead time is exactly matched with the excitation period, thus paving the way to unprecedented speedup of FLIM measurements. In this paper, we present the first single-channel system that implements the novel proposed methodology to be used in modern TCSPC experimental setups. To achieve this goal, we designed a compact detection head, including a custom single-photon avalanche diode externally driven by a fully integrated Active Quenching Circuit (AQC), featuring a finely tunable dead time and a short reset time. The output timing signal is extracted by using a picosecond precision Pick-Up Circuit (PUC) and fed to a newly developed timing module consisting of a mixed-architecture Fast Time to Amplitude Converter (F-TAC) followed by high-performance Analog-to-Digital Converters (ADCs). Data are transmitted in real-time to a Personal Computer (PC) at USB 3.0 rate for specific and custom elaboration. Preliminary experimental results show that the new TCSPC system is suitable for implementing the proposed technique, achieving, indeed, high timing precision along with a count rate as high as 40 Mcps.
Collapse
Affiliation(s)
- S Farina
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - G Acconcia
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - I Labanca
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - M Ghioni
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - I Rech
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| |
Collapse
|
9
|
Di Sieno L, Behera A, Rohilla S, Ferocino E, Contini D, Torricelli A, Krämer B, Koberling F, Pifferi A, Mora AD. Probe-hosted large area silicon photomultiplier and high-throughput timing electronics for enhanced performance time-domain functional near-infrared spectroscopy. BIOMEDICAL OPTICS EXPRESS 2020; 11:6389-6412. [PMID: 33282497 PMCID: PMC7687960 DOI: 10.1364/boe.400868] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/23/2020] [Revised: 09/21/2020] [Accepted: 10/07/2020] [Indexed: 05/06/2023]
Abstract
Two main bottlenecks prevent time-domain diffuse optics instruments to reach their maximum performances, namely the limited light harvesting capability of the detection chain and the bounded data throughput of the timing electronics. In this work, for the first time to our knowledge, we overcome both those limitations using a probe-hosted large area silicon photomultiplier detector coupled to high-throughput timing electronics. The system performances were assessed based on international protocols for diffuse optical imagers showing better figures with respect to a state-of-the-art device. As a first step towards applications, proof-of-principle in-vivo brain activation measurements demonstrated superior signal-to-noise ratio as compared to current technologies.
Collapse
Affiliation(s)
- L. Di Sieno
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - A. Behera
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - S. Rohilla
- PicoQuant Innovation GmbH, Rudower Chaussee 29, 12489 Berlin, Germany
- Charité–Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu and Berlin Institute of Health, Department of Internal Medicine/Infectious Diseases and Respiratory Medicine, Charitéplatz 1, 10117 Berlin, Germany
| | - E. Ferocino
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - D. Contini
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - A. Torricelli
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - B. Krämer
- PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany
| | - F. Koberling
- PicoQuant GmbH, Rudower Chaussee 29, 12489 Berlin, Germany
| | - A. Pifferi
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
- Consiglio Nazionale delle Ricerche, Istituto di Fotonica e Nanotecnologie, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| | - A. Dalla Mora
- Politecnico di Milano, Dipartimento di Fisica, Piazza Leonardo da Vinci 32, 20133 Milano, Italy
| |
Collapse
|
10
|
Datta R, Heaster TM, Sharick JT, Gillette AA, Skala MC. Fluorescence lifetime imaging microscopy: fundamentals and advances in instrumentation, analysis, and applications. JOURNAL OF BIOMEDICAL OPTICS 2020; 25:1-43. [PMID: 32406215 PMCID: PMC7219965 DOI: 10.1117/1.jbo.25.7.071203] [Citation(s) in RCA: 326] [Impact Index Per Article: 81.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 04/24/2020] [Indexed: 05/18/2023]
Abstract
SIGNIFICANCE Fluorescence lifetime imaging microscopy (FLIM) is a powerful technique to distinguish the unique molecular environment of fluorophores. FLIM measures the time a fluorophore remains in an excited state before emitting a photon, and detects molecular variations of fluorophores that are not apparent with spectral techniques alone. FLIM is sensitive to multiple biomedical processes including disease progression and drug efficacy. AIM We provide an overview of FLIM principles, instrumentation, and analysis while highlighting the latest developments and biological applications. APPROACH This review covers FLIM principles and theory, including advantages over intensity-based fluorescence measurements. Fundamentals of FLIM instrumentation in time- and frequency-domains are summarized, along with recent developments. Image segmentation and analysis strategies that quantify spatial and molecular features of cellular heterogeneity are reviewed. Finally, representative applications are provided including high-resolution FLIM of cell- and organelle-level molecular changes, use of exogenous and endogenous fluorophores, and imaging protein-protein interactions with Förster resonance energy transfer (FRET). Advantages and limitations of FLIM are also discussed. CONCLUSIONS FLIM is advantageous for probing molecular environments of fluorophores to inform on fluorophore behavior that cannot be elucidated with intensity measurements alone. Development of FLIM technologies, analysis, and applications will further advance biological research and clinical assessments.
Collapse
Affiliation(s)
- Rupsa Datta
- Morgridge Institute for Research, Madison, Wisconsin, United States
| | - Tiffany M. Heaster
- Morgridge Institute for Research, Madison, Wisconsin, United States
- University of Wisconsin, Department of Biomedical Engineering, Madison, Wisconsin, United States
| | - Joe T. Sharick
- Morgridge Institute for Research, Madison, Wisconsin, United States
| | - Amani A. Gillette
- Morgridge Institute for Research, Madison, Wisconsin, United States
- University of Wisconsin, Department of Biomedical Engineering, Madison, Wisconsin, United States
| | - Melissa C. Skala
- Morgridge Institute for Research, Madison, Wisconsin, United States
- University of Wisconsin, Department of Biomedical Engineering, Madison, Wisconsin, United States
| |
Collapse
|
11
|
Cominelli A, Acconcia G, Labanca I, Ghioni M, Rech I. Accurate non-invasive measurement of the turn-on transition of fast gated single photon avalanche diodes. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:033102. [PMID: 30927784 DOI: 10.1063/1.5056222] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2018] [Accepted: 02/10/2019] [Indexed: 06/09/2023]
Abstract
Recently developed Active Quenching Circuits (AQCs) with fast-gating capabilities allow us to control a single photon avalanche diode with gate windows in the nanosecond and sub-nanosecond range, thus paving the way to advanced applications, especially in the field of time-correlated single photon counting. In this scenario, an accurate measurement of the time needed by the AQC to turn-on the detector is of utmost importance. Indeed, it permits us to evaluate the impact of the system in specific applications and provides a tool to designers to understand AQC limitations and to enhance its performance. Here we propose a simple non-invasive technique to accurately measure the time needed by a gated system to turn on the detector. The effectiveness of the measure has been proved on a gated system, and results have been compared to those obtained starting from the distribution of recorded photons under constant illumination, which is a widely used approach in the literature. The great advantage of the proposed approach is that it avoids typical artifacts that affect other kinds of measurements.
Collapse
Affiliation(s)
- A Cominelli
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - G Acconcia
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - I Labanca
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - M Ghioni
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| | - I Rech
- Dipartimento di Elettronica, Informazione e Bioingegneria, Politecnico di Milano, Piazza L. da Vinci 32, 20133 Milan, Italy
| |
Collapse
|
12
|
Acconcia G, Cominelli A, Ghioni M, Rech I. Fast fully-integrated front-end circuit to overcome pile-up limits in time-correlated single photon counting with single photon avalanche diodes. OPTICS EXPRESS 2018; 26:15398-15410. [PMID: 30114802 DOI: 10.1364/oe.26.015398] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2018] [Accepted: 05/23/2018] [Indexed: 06/08/2023]
Abstract
Time-Correlated Single Photon Counting (TCSPC) is an essential tool in many scientific applications, where the recording of optical pulses with picosecond precision is required. Unfortunately, a key issue has to be faced: distortion phenomena can affect TCSPC experiments at high count rates. In order to avoid this problem, TCSPC experiments have been commonly carried out by limiting the maximum operating frequency of a measurement channel below 5% of the excitation frequency, leading to a long acquisition time. Recently, it has been demonstrated that matching the detector dead time to the excitation period allows to keep distortion around zero regardless of the rate of impinging photons. This solution paves the way to unprecedented measurement speed in TCSPC experiments. In this scenario, the front-end circuits that drive the detector play a crucial role in determining the performance of the system, both in terms of measurement speed and timing performance. Here we present two fully integrated front-end circuits for Single Photon Avalanche Diodes (SPADs): a fast Active Quenching Circuit (AQC) and a fully-differential current pick-up circuit. The AQC can apply very fast voltage variations, as short as 1.6ns, to reset external custom-technology SPAD detectors. A fast reset, indeed, is a key parameter to maximize the measurement speed. The current pick-up circuit is based on a fully differential structure which allows unprecedented rejection of disturbances that typically affect SPAD-based systems at the end of the dead time. The circuit permits to sense the current edge resulting from a photon detection with picosecond accuracy and precision even a few picoseconds after the end of the dead time imposed by the AQC. This is a crucial requirement when the system is operated at high rates. Both circuits have been deeply characterized, especially in terms of achievable measurement speed and timing performance.
Collapse
|