Knüppel F, Malchow S, Sun A, Hussong J, Hartmann A, Wurm FH, Torner B. Viscosity Modeling for Blood and Blood Analog Fluids in Narrow Gap and High Reynolds Numbers Flows. MICROMACHINES 2024; 15:793. [PMID: 38930763 PMCID: PMC11205544 DOI: 10.3390/mi15060793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/15/2024] [Revised: 06/06/2024] [Accepted: 06/13/2024] [Indexed: 06/28/2024]
Abstract
For the optimization of ventricular assist devices (VADs), flow simulations are crucial. Typically, these simulations assume single-phase flow to represent blood flow. However, blood consists of plasma and blood cells, making it a multiphase flow. Cell migration in such flows leads to a heterogeneous cell distribution, significantly impacting flow dynamics, especially in narrow gaps of less than 300 μm found in VADs. In these areas, cells migrate away from the walls, forming a cell-free layer, a phenomenon not usually considered in current VAD simulations. This paper addresses this gap by introducing a viscosity model that accounts for cell migration in microchannels under VAD-relevant conditions. The model is based on local particle distributions measured in a microchannels with a blood analog fluid. We developed a local viscosity distribution for flows with particles/cells and a cell-free layer, applicable to both blood and analog fluids, with particle volume fractions of up to 5%, gap heights of 150 μm, and Reynolds numbers around 100. The model was validated by comparing simulation results with experimental data of blood and blood analog fluid flow on wall shear stresses and pressure losses, showing strong agreement. This model improves the accuracy of simulations by considering local viscosity changes rather than assuming a single-phase fluid. Future developments will extend the model to physiological volume fractions up to 40%.
Collapse
Affiliation(s)
- Finn Knüppel
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18059 Rostock, Germany; (F.K.); (S.M.); (F.-H.W.)
| | - Sasha Malchow
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18059 Rostock, Germany; (F.K.); (S.M.); (F.-H.W.)
| | - Ang Sun
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Jeanette Hussong
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Alexander Hartmann
- Institute of Clinical Chemistry and Laboratory Medicine, Rostock University Medical Center, 18057 Rostock, Germany;
| | - Frank-Hendrik Wurm
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18059 Rostock, Germany; (F.K.); (S.M.); (F.-H.W.)
| | - Benjamin Torner
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18059 Rostock, Germany; (F.K.); (S.M.); (F.-H.W.)
| |
Collapse
|
2
|
Barbosa F, Dueñas-Pamplona J, Abreu CS, Oliveira MSN, Lima RA. Numerical Model Validation of the Blood Flow through a Microchannel Hyperbolic Contraction. MICROMACHINES 2023; 14:1886. [PMID: 37893323 PMCID: PMC10608998 DOI: 10.3390/mi14101886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2023] [Revised: 09/18/2023] [Accepted: 09/28/2023] [Indexed: 10/29/2023]
Abstract
A computational fluid dynamics (CFD) model of blood flow through hyperbolic contraction with a discrete phase model (DPM) was experimentally validated. For this purpose, the positions and velocities of red blood cells (RBCs) flowing in a microchannel with hyperbolic contraction were experimentally assessed using image analysis techniques, and were subsequently compared with the numerical results. The numerically and experimentally obtained velocity fields were in good agreement, with errors smaller than 10%. Additionally, a nearly constant strain rate was observed in the contraction region, which can be attributed to the quasilinear increase in the velocity along the hyperbolic contraction. Therefore, the numerical technique used was validated due to the close similarity between the numerically and experimentally obtained results. The tested CFD model can be used to optimize the microchannel design by minimizing the need to fabricate prototypes and evaluate them experimentally.
Collapse
Affiliation(s)
- Filipe Barbosa
- Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal;
| | - Jorge Dueñas-Pamplona
- Departamento de Ingeniería Energética, Universidad Politécnica de Madrid, 28040 Madrid, Spain;
| | - Cristiano S. Abreu
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, 4800-058 Guimarães, Portugal;
- LABBELS—Associate Laboratory, 4710-057 Braga, Portugal
- Physics Department, Porto Superior Engineering Institute, ISEP, 4200-072 Porto, Portugal
| | - Mónica S. N. Oliveira
- James Weir Fluids Laboratory, Department of Mechanical and Aerospace Engineering, University of Strathclyde, Glasgow G1 1XJ, UK;
| | - Rui A. Lima
- Mechanical Engineering and Resource Sustainability Center (METRICS), University of Minho, 4800-058 Guimarães, Portugal;
- CEFT—Transport Phenomena Research Center, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
- ALiCE—Associate Laboratory in Chemical Engineering, Faculty of Engineering, University of Porto, 4200-465 Porto, Portugal
| |
Collapse
|
3
|
Knüppel F, Sun A, Wurm FH, Hussong J, Torner B. Effect of Particle Migration on the Stress Field in Microfluidic Flows of Blood Analog Fluids at High Reynolds Numbers. MICROMACHINES 2023; 14:1494. [PMID: 37630030 PMCID: PMC10456677 DOI: 10.3390/mi14081494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Revised: 07/19/2023] [Accepted: 07/21/2023] [Indexed: 08/27/2023]
Abstract
In the present paper, we investigate how the reductions in shear stresses and pressure losses in microfluidic gaps are directly linked to the local characteristics of cell-free layers (CFLs) at channel Reynolds numbers relevant to ventricular assist device (VAD) applications. For this, detailed studies of local particle distributions of a particulate blood analog fluid are combined with wall shear stress and pressure loss measurements in two complementary set-ups with identical flow geometry, bulk Reynolds numbers and particle Reynolds numbers. For all investigated particle volume fractions of up to 5%, reductions in the stress and pressure loss were measured in comparison to a flow of an equivalent homogeneous fluid (without particles). We could explain this due to the formation of a CFL ranging from 10 to 20 μm. Variations in the channel Reynolds number between Re = 50 and 150 did not lead to measurable changes in CFL heights or stress reductions for all investigated particle volume fractions. These measurements were used to describe the complete chain of how CFL formation leads to a stress reduction, which reduces the apparent viscosity of the suspension and results in the Fåhræus-Lindqvist effect. This chain of causes was investigated for the first time for flows with high Reynolds numbers (Re∼100), representing a flow regime which can be found in the narrow gaps of a VAD.
Collapse
Affiliation(s)
- Finn Knüppel
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Ang Sun
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Frank-Hendrik Wurm
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| | - Jeanette Hussong
- Institute for Fluid Mechanics and Aerodynamics, Technical University of Darmstadt, 64287 Darmstadt, Germany; (A.S.); (J.H.)
| | - Benjamin Torner
- Institute of Turbomachinery, Faculty for Mechanical Engineering and Ship Design, University of Rostock, 18055 Rostock, Germany; (F.K.); (F.-H.W.)
| |
Collapse
|
4
|
Gracka M, Lima R, Miranda JM, Student S, Melka B, Ostrowski Z. Red blood cells tracking and cell-free layer formation in a microchannel with hyperbolic contraction: A CFD model validation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 226:107117. [PMID: 36122496 DOI: 10.1016/j.cmpb.2022.107117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/07/2022] [Revised: 08/16/2022] [Accepted: 09/05/2022] [Indexed: 06/15/2023]
Abstract
BACKGROUND AND OBJECTIVE In recent years, progress in microfabrication technologies has attracted the attention of researchers across disciplines. Microfluidic devices have the potential to be developed into powerful tools that can elucidate the biophysical behavior of blood flow in microvessels. Such devices can also be used to separate the suspended physiological fluid from whole in vitro blood, which includes cells. Therefore, it is essential to acquire a detailed description of the complex interaction between erythrocytes (red blood cells; RBCs) and plasma. RBCs tend to undergo axial migration caused by occurrence of the Fåhræus-Lindqvist effect. These dynamics result in a cell-free layer (CFL), or a low volume fraction of cells, near the vessel wall. The aim of the paper is to develop a numerical model capable of reproducing the behavior of multiphase flow in a microchannel obtained under laboratory conditions and to compare two multiphase modelling techniques Euler-Euler and Euler-Lagrange. METHODS In this work, we employed a numerical Computational Fluid Dynamics (CFD) model of the blood flow within microchannels with two hyperbolic contraction shapes. The simulation was used to reproduce the blood flow behavior in a microchannel under laboratory conditions, where the CFL formation is visible downstream of the hyperbolic contraction. The multiphase numerical model was developed using Euler-Euler and hybrid Euler-Lagrange approaches. The hybrid CFD simulation of the RBC transport model was performed using a Discrete Phase Model. Blood was assumed to be a nonhomogeneous mixture of two components: dextran, whose properties are consistent with plasma, and RBCs, at a hematocrit of 5% (percent by volume of RBCs). RESULTS The results show a 5 μm thick CFL in a microchannel with a broader contraction and a 35 μm thick CFL in a microchannel with a narrower contraction. The RBC volume fraction in the CFL is less than 2%, compared to 7-8% in the core flow. The results are consistent for both multiphase simulation techniques used. The simulation results were then validated against the experimentally-measured CFL in each of the studied microchannel geometries. CONCLUSIONS Reasonable agreement between experiments and simulations was achieved. A validated model such as the one tested in this study can expedite the microchannel design process by minimizing the need to prefabricate prototypes and test them under laboratory conditions.
Collapse
Affiliation(s)
- Maria Gracka
- Department of Thermal Technology, Biomedical Engineering Laboratory, Silesian University of Technology, Gliwice, Poland.
| | - Rui Lima
- MEtRiCS, DME, School of Engineering, University of Minho, Braga, Portugal; CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Porto, Portugal
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Porto, Portugal
| | - Sebastian Student
- Department of Systems Biology and Engineering, Silesian University of Technology, Gliwice, Poland; Biotechnology Centre, Silesian University of Technology, Gliwice, Poland
| | - Bartłomiej Melka
- Department of Thermal Technology, Biomedical Engineering Laboratory, Silesian University of Technology, Gliwice, Poland
| | - Ziemowit Ostrowski
- Department of Thermal Technology, Biomedical Engineering Laboratory, Silesian University of Technology, Gliwice, Poland
| |
Collapse
|
5
|
Rubio A, López M, Rodrigues T, Campo-Deaño L, Vega EJ. A particulate blood analogue based on artificial viscoelastic blood plasma and RBC-like microparticles at a concentration matching the human haematocrit. SOFT MATTER 2022; 18:7510-7523. [PMID: 36148801 DOI: 10.1039/d2sm00947a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
There has been enormous interest in the production of fluids with rheological properties similar to those of real blood over the last few years. Application fields range from biomicrofluidics (microscale) to forensic science (macroscale). The inclusion of flexible microparticles in blood analogue fluids has been demonstrated to be essential in order to reproduce the behaviour of blood flow in these fields. Here, we describe a protocol to produce a whole human blood analogue composed of a proposed plasma analogue and flexible spherical microparticles that mimic the key structural attributes of RBCs (size and mechanical properties), at a concentration matching the human haematocrit (∼42% by volume). Polydimethylsiloxane (PDMS) flexible microparticles were used to mimic RBCs, whose capability to deform is tunable by means of the mixing ratio of the PDMS precursor. Their flow through glass micronozzles allowed us to find the appropriate mixing ratio of PDMS to have approximately the same Young's modulus (E) as that exhibited by real RBCs. Shear and extensional rheology and microrheology techniques were used to match the properties exhibited by human plasma and whole blood at body temperature (37 °C). Finally, we study the flow of our proposed fluid through a microfluidic channel, showing the in vitro reproduction of the multiphase flow effects taking place in the human microcirculatory system, such as the cell-free layer (CFL) and the Fåhræus-Lindqvist effect. A macroscale application in the field of forensic science is also presented, concerning the impact of our blood analogue droplets on a solid surface for bloodstain pattern analysis.
Collapse
Affiliation(s)
- A Rubio
- Depto. de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006, Badajoz, Spain. ejvega@unex
| | - M López
- Depto. de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006, Badajoz, Spain. ejvega@unex
| | - T Rodrigues
- CEFT, Depto. de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - L Campo-Deaño
- CEFT, Depto. de Engenharia Mecânica, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
- ALiCE, Faculdade de Engenharia, Universidade do Porto, Rua Dr. Roberto Frias, 4200-465, Porto, Portugal
| | - E J Vega
- Depto. de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006, Badajoz, Spain. ejvega@unex
| |
Collapse
|
6
|
Geometry effect in multi-step crossflow microfluidic devices for red blood cells separation and deformability assessment. Biomed Microdevices 2022; 24:20. [PMID: 35670892 DOI: 10.1007/s10544-022-00616-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/24/2022] [Indexed: 11/02/2022]
Abstract
The efficient separation of blood components using microfluidic systems can help to improve the detection and diagnosis of several diseases, such as malaria and diabetes. Therefore, a novel multi-step microfluidic device, based on passive crossflow filters was developed. Three different designs were proposed, fabricated and tested in order to evaluate the most suitable geometry to perform, simultaneously, blood cells separation and cell deformability measurements. All the proposed geometries include a main channel and three sequential separation steps, all comprised of symmetrical crossflow filters, with multiple rows of pillars, to reduce the amount of red blood cells (RBCs) flowing to the outlets of the microfluidic device (MD). Sets of hyperbolic constrictions located at the outlets allow the assessment of cells deformability. Based on the proposed geometries, the three correspondent MD were evaluated and compared, by measuring the RBCs velocities, the cell-free layer (CFL) effect through the microchannels and by quantifying the amount of RBCs at the outlets. The results suggest that the proposed MD 3 configuration was the most effective one for the desired application, due to the formation of a wider CFL. As a result, a minor amount of RBCs flow through the hyperbolic contraction at the third separation level of the device. Nevertheless, for all the proposed geometries, the existence of three separation levels shows that it is possible to achieve a highly efficient cell separation. If needed, such microdevices have the potential for further improvements by increasing the number of separation levels, aiming the total separation of blood cells from plasma.
Collapse
|
7
|
Miranda I, Souza A, Sousa P, Ribeiro J, Castanheira EMS, Lima R, Minas G. Properties and Applications of PDMS for Biomedical Engineering: A Review. J Funct Biomater 2021; 13:2. [PMID: 35076525 PMCID: PMC8788510 DOI: 10.3390/jfb13010002] [Citation(s) in RCA: 147] [Impact Index Per Article: 49.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/13/2021] [Accepted: 12/16/2021] [Indexed: 12/14/2022] Open
Abstract
Polydimethylsiloxane (PDMS) is an elastomer with excellent optical, electrical and mechanical properties, which makes it well-suited for several engineering applications. Due to its biocompatibility, PDMS is widely used for biomedical purposes. This widespread use has also led to the massification of the soft-lithography technique, introduced for facilitating the rapid prototyping of micro and nanostructures using elastomeric materials, most notably PDMS. This technique has allowed advances in microfluidic, electronic and biomedical fields. In this review, an overview of the properties of PDMS and some of its commonly used treatments, aiming at the suitability to those fields' needs, are presented. Applications such as microchips in the biomedical field, replication of cardiovascular flow and medical implants are also reviewed.
Collapse
Affiliation(s)
- Inês Miranda
- Center for MicroElectromechanical Systems (CMEMS-UMinho), Campus de Azurém, University of Minho, 4800-058 Guimaraes, Portugal; (I.M.); (P.S.); (G.M.)
| | - Andrews Souza
- MEtRICs, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimaraes, Portugal;
| | - Paulo Sousa
- Center for MicroElectromechanical Systems (CMEMS-UMinho), Campus de Azurém, University of Minho, 4800-058 Guimaraes, Portugal; (I.M.); (P.S.); (G.M.)
| | - João Ribeiro
- Centro de Investigação de Montanha (CIMO), Campus de Santa Apolónia, Instituto Politécnico de Bragança, 5300-253 Braganca, Portugal;
| | - Elisabete M. S. Castanheira
- Centre of Physics of Minho and Porto Universities (CF-UM-UP), Campus de Gualtar, University of Minho, 4710-057 Braga, Portugal;
| | - Rui Lima
- MEtRICs, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimaraes, Portugal;
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal
| | - Graça Minas
- Center for MicroElectromechanical Systems (CMEMS-UMinho), Campus de Azurém, University of Minho, 4800-058 Guimaraes, Portugal; (I.M.); (P.S.); (G.M.)
| |
Collapse
|
8
|
Sadek SH, Rubio M, Lima R, Vega EJ. Blood Particulate Analogue Fluids: A Review. MATERIALS (BASEL, SWITZERLAND) 2021; 14:2451. [PMID: 34065125 PMCID: PMC8126041 DOI: 10.3390/ma14092451] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Revised: 04/30/2021] [Accepted: 05/01/2021] [Indexed: 11/16/2022]
Abstract
Microfluidics has proven to be an extraordinary working platform to mimic and study blood flow phenomena and the dynamics of components of the human microcirculatory system. However, the use of real blood increases the complexity to perform these kinds of in vitro blood experiments due to diverse problems such as coagulation, sample storage, and handling problems. For this reason, interest in the development of fluids with rheological properties similar to those of real blood has grown over the last years. The inclusion of microparticles in blood analogue fluids is essential to reproduce multiphase effects taking place in a microcirculatory system, such as the cell-free layer (CFL) and Fähraeus-Lindqvist effect. In this review, we summarize the progress made in the last twenty years. Size, shape, mechanical properties, and even biological functionalities of microparticles produced/used to mimic red blood cells (RBCs) are critically exposed and analyzed. The methods developed to fabricate these RBC templates are also shown. The dynamic flow/rheology of blood particulate analogue fluids proposed in the literature (with different particle concentrations, in most of the cases, relatively low) is shown and discussed in-depth. Although there have been many advances, the development of a reliable blood particulate analogue fluid, with around 45% by volume of microparticles, continues to be a big challenge.
Collapse
Affiliation(s)
- Samir Hassan Sadek
- Departamento de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006 Badajoz, Spain; (S.H.S.); (M.R.)
| | - Manuel Rubio
- Departamento de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006 Badajoz, Spain; (S.H.S.); (M.R.)
| | - Rui Lima
- MEtRICs, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimarães, Portugal;
- Transport Phenomena Research Center, Department of Chemical Engineering, Faculty of Engineering, University of Porto, Rua Dr. Roberto Frias, 4200-465 Porto, Portugal
| | - Emilio José Vega
- Departamento de Ingeniería Mecánica, Energética y de los Materiales and Instituto de Computación Científica Avanzada (ICCAEx), Universidad de Extremadura, E-06006 Badajoz, Spain; (S.H.S.); (M.R.)
| |
Collapse
|
9
|
Carneiro J, Lima R, Campos JBLM, Miranda JM. A microparticle blood analogue suspension matching blood rheology. SOFT MATTER 2021; 17:3963-3974. [PMID: 33724275 DOI: 10.1039/d1sm00106j] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The handling of blood in vitro is demanding because of ethical, economical and safety issues. Although several Newtonian and non-Newtonian blood analogues are found in the literature, few studies have used particles to mimic red blood cells (RBCs) and built an analogue with similar rheological properties of blood. This work reports the development of a blood analogue suspension composed of polydimethylsiloxane (PDMS) microparticles with an average diameter of ∼7 μm. High throughput production of PDMS particles is possible using a multi-stage membrane emulsification process; up to ∼6 mL of microparticles are manufactured in 3 hours. PDMS particles at a concentration of around 21% (w/w) at 20 °C present steady, oscillatory and extensional rheologies very similar to those of blood under physiological conditions (37 °C and ∼41% hematocrit), making them a good candidate whole blood analogue. Also, flow studies were performed in microchannels with contraction to study the cell-free layer (CFL) formation and particle deformation, achieving good qualitative results. Using the procedure developed, it is possible to obtain blood analogue fluids with a shelf life of at least 6 months.
Collapse
Affiliation(s)
- J Carneiro
- CEFT, Transport Phenomena Research Center, Chemical Engineering Department, Faculty of Engineering, University of Porto, 4050-465 Porto, Portugal.
| | | | | | | |
Collapse
|
10
|
Xia HM, Wu JW, Zheng JJ, Zhang J, Wang ZP. Nonlinear microfluidics: device physics, functions, and applications. LAB ON A CHIP 2021; 21:1241-1268. [PMID: 33877234 DOI: 10.1039/d0lc01120g] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The microfluidic flow is typically laminar due to the dominant viscous effects. At Reynolds numbers far below 1 (Re ≪ 1), the fluid inertia can be neglected. For the steady flow of incompressible Newtonian fluids, it approaches linear Stokes flow. At intermediate Re, there exists a weak-inertia flow regime where secondary flows such as Dean vortices are accessible for microfluidic manipulations. Apart from the fluid inertia, other nonlinear factors such as the non-Newtonian fluid properties, concurrent flow of dissimilar fluids, compliant fluidic structures and stimuli-responsive materials can also cause intriguing flow behaviours. Through proper designs, they can be applied for a variety of microfluidic components including mixers, valves, oscillators, stabilizers and auto-regulators etc., greatly enriching the microfluidic flow control and manipulation strategies. Due to its unique working characteristics and advantages, nonlinear microfluidics has increasingly attracted extensive attention. This review presents a systematic survey on this subject. The designs of typical nonlinear microfluidic devices, their working mechanisms, key applications, and the perspective of their future developments will be discussed. The nonlinear microfluidic techniques are believed to play an essential role in the next generation of highly-integrated, automated, and intelligent microfluidics.
Collapse
Affiliation(s)
- H M Xia
- School of Mechanical Engineering, Nanjing University of Science and Technology, Nanjing 210094, P. R. China.
| | | | | | | | | |
Collapse
|
11
|
Carvalho V, Maia I, Souza A, Ribeiro J, Costa P, Puga H, Teixeira S, Lima RA. In vitro
Biomodels in Stenotic Arteries to Perform Blood Analogues Flow Visualizations and Measurements: A Review. Open Biomed Eng J 2020. [DOI: 10.2174/1874120702014010087] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
Cardiovascular diseases are one of the leading causes of death globally and the most common pathological process is atherosclerosis. Over the years, these cardiovascular complications have been extensively studied by applying in vivo, in vitro and numerical methods (in silico). In vivo studies represent more accurately the physiological conditions and provide the most realistic data. Nevertheless, these approaches are expensive, and it is complex to control several physiological variables. Hence, the continuous effort to find reliable alternative methods has been growing. In the last decades, numerical simulations have been widely used to assess the blood flow behavior in stenotic arteries and, consequently, providing insights into the cardiovascular disease condition, its progression and therapeutic optimization. However, it is necessary to ensure its accuracy and reliability by comparing the numerical simulations with clinical and experimental data. For this reason, with the progress of the in vitro flow measurement techniques and rapid prototyping, experimental investigation of hemodynamics has gained widespread attention. The present work reviews state-of-the-art in vitro macro-scale arterial stenotic biomodels for flow measurements, summarizing the different fabrication methods, blood analogues and highlighting advantages and limitations of the most used techniques.
Collapse
|
12
|
Carvalho V, Rodrigues N, Ribeiro R, Costa PF, Teixeira JCF, Lima RA, Teixeira SFCF. Hemodynamic study in 3D printed stenotic coronary artery models: experimental validation and transient simulation. Comput Methods Biomech Biomed Engin 2020; 24:623-636. [PMID: 33225743 DOI: 10.1080/10255842.2020.1842377] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
Atherosclerosis is a progressive disease that can significantly reduce blood supply to vital organs, being one of the main causes of death worldwide. In this work, a numerical and experimental study in 3D printed stenotic coronary arteries, considering both steady and pulsatile blood flow conditions, is presented. The results revealed that a degree of stenosis superior to 50% creates disturbed flows downstream of the contraction, with an accented increase in the wall shear stress measurements at the stenosis throat. Finally, the multiphase mixture was investigated and compared with a single-phase modelling, and only slight differences were observed right after the stenosis throat.
Collapse
Affiliation(s)
- Violeta Carvalho
- MEtRICs Research Center, University of Minho, Guimarães, Portugal
| | - Nelson Rodrigues
- ALGORITMI Research Center, University of Minho, Guimarães, Portugal
| | | | | | | | - Rui A Lima
- MEtRICs Research Center, University of Minho, Guimarães, Portugal.,CEFT, Faculty of Engineering, University of Porto, Porto, Portugal
| | | |
Collapse
|
13
|
Elitas M, Sengul E. Quantifying Heterogeneity According to Deformation of the U937 Monocytes and U937-Differentiated Macrophages Using 3D Carbon Dielectrophoresis in Microfluidics. MICROMACHINES 2020; 11:mi11060576. [PMID: 32521676 PMCID: PMC7345647 DOI: 10.3390/mi11060576] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2020] [Revised: 06/04/2020] [Accepted: 06/08/2020] [Indexed: 12/14/2022]
Abstract
A variety of force fields have thus far been demonstrated to investigate electromechanical properties of cells in a microfluidic platform which, however, are mostly based on fluid shear stress and may potentially cause irreversible cell damage. This work presents dielectric movement and deformation measurements of U937 monocytes and U937-differentiated macrophages in a low conductive medium inside a 3D carbon electrode array. Here, monocytes exhibited a crossover frequency around 150 kHz and presented maximum deformation index at 400 kHz and minimum deformation index at 1 MHz frequencies at 20 Vpeak-peak. Although macrophages were differentiated from monocytes, their crossover frequency was lower than 50 kHz at 10 Vpeak-peak. The change of the deformation index for macrophages was more constant and lower than the monocyte cells. Both dielectric mobility and deformation spectra revealed significant differences between the dielectric responses of U937 monocytes and U937-differentiated macrophages, which share the same origin. This method can be used for label-free, specific, and sensitive single-cell characterization. Besides, damage of the cells by aggressive shear forces can, hence, be eliminated and cells can be used for downstream analysis. Our results showed that dielectric mobility and deformation have a great potential as an electromechanical biomarker to reliably characterize and distinguish differentiated cell populations from their progenitors.
Collapse
Affiliation(s)
- Meltem Elitas
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey;
- Sabanci University Nanotechnology Research and Application Center, Istanbul 34956, Turkey
- Correspondence: ; Tel.: +90-538-810-2930
| | - Esra Sengul
- Faculty of Engineering and Natural Sciences, Sabanci University, Istanbul 34956, Turkey;
| |
Collapse
|
14
|
3D Printed Biomodels for Flow Visualization in Stenotic Vessels: An Experimental and Numerical Study. MICROMACHINES 2020; 11:mi11060549. [PMID: 32485816 PMCID: PMC7344925 DOI: 10.3390/mi11060549] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 05/17/2020] [Accepted: 05/25/2020] [Indexed: 12/13/2022]
Abstract
Atherosclerosis is one of the most serious and common forms of cardiovascular disease and a major cause of death and disability worldwide. It is a multifactorial and complex disease that promoted several hemodynamic studies. Although in vivo studies more accurately represent the physiological conditions, in vitro experiments more reliably control several physiological variables and most adequately validate numerical flow studies. Here, a hemodynamic study in idealized stenotic and healthy coronary arteries is presented by applying both numerical and in vitro approaches through computational fluid dynamics simulations and a high-speed video microscopy technique, respectively. By means of stereolithography 3D printing technology, biomodels with three different resolutions were used to perform experimental flow studies. The results showed that the biomodel printed with a resolution of 50 μm was able to most accurately visualize flow due to its lowest roughness values (Ra = 1.8 μm). The flow experimental results showed a qualitatively good agreement with the blood flow numerical data, providing a clear observation of recirculation regions when the diameter reduction reached 60%.
Collapse
|
15
|
Kim CM, Choi HJ, Kim GM. 512-Channel Geometric Droplet-Splitting Microfluidic Device by Injection of Premixed Emulsion for Microsphere Production. Polymers (Basel) 2020; 12:polym12040776. [PMID: 32244738 PMCID: PMC7240624 DOI: 10.3390/polym12040776] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 03/24/2020] [Accepted: 03/25/2020] [Indexed: 11/16/2022] Open
Abstract
We present a 512-channel geometric droplet-splitting microfluidic device that involves the injection of a premixed emulsion for microsphere production. The presented microfluidic device was fabricated using conventional photolithography and polydimethylsiloxane casting. The fabricated microfluidic device consisted of 512 channels with 256 T-junctions in the last branch. Five hundred and twelve microdroplets with a narrow size distribution were produced from a single liquid droplet. The diameter and size distribution of prepared micro water droplets were 35.29 µm and 8.8% at 10 mL/h, respectively. Moreover, we attempted to prepare biocompatible microspheres for demonstrating the presented approach. The diameter and size distribution of the prepared poly (lactic-co-glycolic acid) microspheres were 6.56 µm and 8.66% at 10 mL/h, respectively. To improve the monodispersity of the microspheres, we designed an additional post array part in the 512-channel geometric droplet-splitting microfluidic device. The monodispersity of the microdroplets prepared with the microfluidic device combined with the post array part exhibited a significant improvement.
Collapse
Affiliation(s)
- Chul Min Kim
- Department of Mechanical Engineering, Korea Polytechnic University, Siheung-Si 15073, Korea;
| | - Hye Jin Choi
- School of Mechanical Engineering, Kyungpook National University, Daegu 41566, Korea;
| | - Gyu Man Kim
- School of Mechanical Engineering, Kyungpook National University, Daegu 41566, Korea;
- Correspondence: ; Tel.: +82-053-950-7570
| |
Collapse
|
16
|
Advances in Computational Fluid Mechanics in Cellular Flow Manipulation: A Review. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9194041] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Recently, remarkable developments have taken place, leading to significant improvements in microfluidic methods to capture subtle biological effects down to single cells. As microfluidic devices are getting sophisticated, design optimization through experimentations is becoming more challenging. As a result, numerical simulations have contributed to this trend by offering a better understanding of cellular microenvironments hydrodynamics and optimizing the functionality of the current/emerging designs. The need for new marketable designs with advantageous hydrodynamics invokes easier access to efficient as well as time-conservative numerical simulations to provide screening over cellular microenvironments, and to emulate physiological conditions with high accuracy. Therefore, an excerpt overview on how each numerical methodology and associated handling software works, and how they differ in handling underlying hydrodynamic of lab-on-chip microfluidic is crucial. These numerical means rely on molecular and continuum levels of numerical simulations. The current review aims to serve as a guideline for researchers in this area by presenting a comprehensive characterization of various relevant simulation techniques.
Collapse
|
17
|
A Microfluidic Deformability Assessment of Pathological Red Blood Cells Flowing in a Hyperbolic Converging Microchannel. MICROMACHINES 2019; 10:mi10100645. [PMID: 31557932 PMCID: PMC6843121 DOI: 10.3390/mi10100645] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2019] [Revised: 09/20/2019] [Accepted: 09/24/2019] [Indexed: 12/25/2022]
Abstract
The loss of the red blood cells (RBCs) deformability is related with many human diseases, such as malaria, hereditary spherocytosis, sickle cell disease, or renal diseases. Hence, during the last years, a variety of technologies have been proposed to gain insights into the factors affecting the RBCs deformability and their possible direct association with several blood pathologies. In this work, we present a simple microfluidic tool that provides the assessment of motions and deformations of RBCs of end-stage kidney disease (ESKD) patients, under a well-controlled microenvironment. All of the flow studies were performed within a hyperbolic converging microchannels where single-cell deformability was assessed under a controlled homogeneous extensional flow field. By using a passive microfluidic device, RBCs passing through a hyperbolic-shaped contraction were measured by a high-speed video microscopy system, and the velocities and deformability ratios (DR) calculated. Blood samples from 27 individuals, including seven healthy controls and 20 having ESKD with or without diabetes, were analysed. The obtained data indicates that the proposed device is able to detect changes in DR of the RBCs, allowing for distinguishing the samples from the healthy controls and the patients. Overall, the deformability of ESKD patients with and without diabetes type II is lower in comparison with the RBCs from the healthy controls, with this difference being more evident for the group of ESKD patients with diabetes. RBCs from ESKD patients without diabetes elongate on average 8% less, within the hyperbolic contraction, as compared to healthy controls; whereas, RBCs from ESKD patients with diabetes elongate on average 14% less than the healthy controls. The proposed strategy can be easily transformed into a simple and inexpensive diagnostic microfluidic system to assess blood cells deformability due to the huge progress in image processing and high-speed microvisualization technology.
Collapse
|
18
|
Catarino SO, Rodrigues RO, Pinho D, Miranda JM, Minas G, Lima R. Blood Cells Separation and Sorting Techniques of Passive Microfluidic Devices: From Fabrication to Applications. MICROMACHINES 2019; 10:mi10090593. [PMID: 31510012 PMCID: PMC6780402 DOI: 10.3390/mi10090593] [Citation(s) in RCA: 60] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Revised: 09/03/2019] [Accepted: 09/06/2019] [Indexed: 01/23/2023]
Abstract
Since the first microfluidic device was developed more than three decades ago, microfluidics is seen as a technology that exhibits unique features to provide a significant change in the way that modern biology is performed. Blood and blood cells are recognized as important biomarkers of many diseases. Taken advantage of microfluidics assets, changes on blood cell physicochemical properties can be used for fast and accurate clinical diagnosis. In this review, an overview of the microfabrication techniques is given, especially for biomedical applications, as well as a synopsis of some design considerations regarding microfluidic devices. The blood cells separation and sorting techniques were also reviewed, highlighting the main achievements and breakthroughs in the last decades.
Collapse
Affiliation(s)
- Susana O Catarino
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Raquel O Rodrigues
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Diana Pinho
- Research Centre in Digitalization and Intelligent Robotics (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal
| | - Graça Minas
- Center for MicroElectromechanical Systems (CMEMS-UMinho), University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP), Rua Roberto Frias, 4200-465 Porto, Portugal.
- MEtRICs, Mechanical Engineering Department, University of Minho, Campus de Azurém, 4800-058 Guimarães, Portugal.
| |
Collapse
|
19
|
Cho M, Hong SO, Lee SH, Hyun K, Kim JM. Effects of Ionic Strength on Lateral Particle Migration in Shear-Thinning Xanthan Gum Solutions. MICROMACHINES 2019; 10:E535. [PMID: 31443169 PMCID: PMC6723194 DOI: 10.3390/mi10080535] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/21/2019] [Revised: 08/08/2019] [Accepted: 08/12/2019] [Indexed: 01/22/2023]
Abstract
Viscoelastic fluids, including particulate systems, are found in various biological and industrial systems including blood flow, food, cosmetics, and electronic materials. Particles suspended in viscoelastic fluids such as polymer solutions migrate laterally, forming spatially segregated streams in pressure-driven flow. Viscoelastic particle migration was recently applied to microfluidic technologies including particle counting and sorting and the micromechanical measurement of living cells. Understanding the effects on equilibrium particle positions of rheological properties of suspending viscoelastic fluid is essential for designing microfluidic applications. It has been considered that the shear-thinning behavior of viscoelastic fluid is a critical factor in determining the equilibrium particle positions. This work presents the lateral particle migration in two different xanthan gum-based viscoelastic fluids with similar shear-thinning viscosities and the linear viscoelastic properties. The flexibility and contour length of the xanthan gum molecules were tuned by varying the ionic strength of the solvent. Particles suspended in flexible and short xanthan gum solution, dissolved at high ionic strength, migrated toward the corners in a square channel, whereas particles in the rigid and long xanthan gum solutions in deionized water migrated toward the centerline. This work suggests that the structural properties of polymer molecules play significant roles in determining the equilibrium positions in shear-thinning fluids, despite similar bulk rheological properties. The current results are expected to be used in a wide range of applications such as cell counting and sorting.
Collapse
Affiliation(s)
- Mira Cho
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea
| | - Sun Ok Hong
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea
| | - Seung Hak Lee
- School of Chemical and Biomolecular Engineering, Pusan National University, Busan 46241, Korea
| | - Kyu Hyun
- School of Chemical and Biomolecular Engineering, Pusan National University, Busan 46241, Korea.
| | - Ju Min Kim
- Department of Energy Systems Research, Ajou University, Suwon 16499, Korea.
- Department of Chemical Engineering, Ajou University, Suwon 16499, Korea.
| |
Collapse
|
20
|
A Passive Microfluidic Device Based on Crossflow Filtration for Cell Separation Measurements: A Spectrophotometric Characterization. BIOSENSORS-BASEL 2018; 8:bios8040125. [PMID: 30544881 PMCID: PMC6316345 DOI: 10.3390/bios8040125] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/27/2018] [Revised: 12/02/2018] [Accepted: 12/04/2018] [Indexed: 01/04/2023]
Abstract
Microfluidic devices have been widely used as a valuable research tool for diagnostic applications. Particularly, they have been related to the successful detection of different diseases and conditions by assessing the mechanical properties of red blood cells (RBCs). Detecting deformability changes in the cells and being able to separate those cells may be a key factor in assuring the success of detection of some blood diseases with diagnostic devices. To detect and separate the chemically modified RBCs (mimicking disease-infected RBCs) from healthy RBCs, the present work proposes a microfluidic device comprising a sequence of pillars with different gaps and nine different outlets used to evaluate the efficiency of the device by measuring the optical absorption of the collected samples. This latter measurement technique was tested to distinguish between healthy RBCs and RBCs chemically modified with glutaraldehyde. The present study indicates that it was possible to detect a slight differences between the samples using an optical absorption spectrophotometric setup. Hence, the proposed microfluidic device has the potential to perform in one single step a partial passive separation of RBCs based on their deformability.
Collapse
|
21
|
Microfluidic Deformability Study of an Innovative Blood Analogue Fluid Based on Giant Unilamellar Vesicles. J Funct Biomater 2018; 9:jfb9040070. [PMID: 30518160 PMCID: PMC6306889 DOI: 10.3390/jfb9040070] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2018] [Revised: 11/12/2018] [Accepted: 11/27/2018] [Indexed: 11/16/2022] Open
Abstract
Blood analogues have long been a topic of interest in biofluid mechanics due to the safety and ethical issues involved in the collection and handling of blood samples. Although the current blood analogue fluids can adequately mimic the rheological properties of blood from a macroscopic point of view, at the microscopic level blood analogues need further development and improvement. In this work, an innovative blood analogue containing giant unilamellar vesicles (GUVs) was developed to mimic the flow behavior of red blood cells (RBCs). A natural lipid mixture, soybean lecithin, was used for the GUVs preparation, and three different lipid concentrations were tested (1 × 10-3 M, 2 × 10-3 M and 4 × 10-3 M). GUV solutions were prepared by thin film hydration with a buffer, followed by extrusion. It was found that GUVs present diameters between 5 and 7 µm which are close to the size of human RBCs. Experimental flow studies of three different GUV solutions were performed in a hyperbolic-shaped microchannel in order to measure the GUVs deformability when subjected to a homogeneous extensional flow. The result of the deformation index (DI) of the GUVs was about 0.5, which is in good agreement with the human RBC's DI. Hence, the GUVs developed in this study are a promising way to mimic the mechanical properties of the RBCs and to further develop particulate blood analogues with flow properties closer to those of real blood.
Collapse
|
22
|
Local Hematocrit Fluctuation Induced by Malaria-Infected Red Blood Cells and Its Effect on Microflow. BIOMED RESEARCH INTERNATIONAL 2018; 2018:8065252. [PMID: 29850568 PMCID: PMC5937607 DOI: 10.1155/2018/8065252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Revised: 03/06/2018] [Accepted: 03/13/2018] [Indexed: 11/17/2022]
Abstract
We investigate numerically the microscale blood flow in which red blood cells (RBCs) are partially infected by Plasmodium falciparum, the malaria parasite. The infected RBCs are modeled as more rigid cells with less deformability than healthy ones. Our study illustrates that, in a 10 μm microvessel in low-hematocrit conditions (18% and 27%), the Plasmodium falciparum-infected red blood cells (Pf-IRBCs) and healthy ones first form a train of cells. Because of the slow moving of the Pf-IRBCs, the local hematocrit (Hct) near the Pf-IRBCs is then increased, to approximately 40% or even higher values. This increase of the local hematocrit is temporary and is kept for a longer length of time because of the long RBC train formed in 27%-Hct condition. Similar hematocrit elevation at the downstream region with 45%-Hct in the same 10 μm microvessel is also observed with the cells randomly located. In 20 μm microvessels with 45%-Hct, the Pf-IRBCs slow down the velocity of the healthy red blood cells (HRBCs) around them and then locally elevate the volume fraction and result in the accumulation of the RBCs at the center of the vessels, thus leaving a thicker cell free layer (CFL) near the vessel wall than normal. Variation of wall shear stress (WSS) is caused by the fluctuation of local Hct and the distance between the wall and the RBCs. Moreover, in high-hematocrit condition (45%), malaria-infected cells have a tendency to migrate to the edge of the aggregates which is due to the uninterrupted hydrodynamic interaction between the HRBCs and Pf-IRBC. Our results suggest that the existence of Pf-IRBCs is a nonnegligible factor for the fluctuation of hematocrit and WSS and also contributes to the increase of CFL of pathological blood flow in microvessels. The numerical approach presented has the potential to be utilized to RBC disorders and other hematologic diseases.
Collapse
|
23
|
Bento D, Rodrigues RO, Faustino V, Pinho D, Fernandes CS, Pereira AI, Garcia V, Miranda JM, Lima R. Deformation of Red Blood Cells, Air Bubbles, and Droplets in Microfluidic Devices: Flow Visualizations and Measurements. MICROMACHINES 2018; 9:E151. [PMID: 30424085 PMCID: PMC6187860 DOI: 10.3390/mi9040151] [Citation(s) in RCA: 45] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/10/2018] [Revised: 03/21/2018] [Accepted: 03/21/2018] [Indexed: 12/30/2022]
Abstract
Techniques, such as micropipette aspiration and optical tweezers, are widely used to measure cell mechanical properties, but are generally labor-intensive and time-consuming, typically involving a difficult process of manipulation. In the past two decades, a large number of microfluidic devices have been developed due to the advantages they offer over other techniques, including transparency for direct optical access, lower cost, reduced space and labor, precise control, and easy manipulation of a small volume of blood samples. This review presents recent advances in the development of microfluidic devices to evaluate the mechanical response of individual red blood cells (RBCs) and microbubbles flowing in constriction microchannels. Visualizations and measurements of the deformation of RBCs flowing through hyperbolic, smooth, and sudden-contraction microchannels were evaluated and compared. In particular, we show the potential of using hyperbolic-shaped microchannels to precisely control and assess small changes in RBC deformability in both physiological and pathological situations. Moreover, deformations of air microbubbles and droplets flowing through a microfluidic constriction were also compared with RBCs deformability.
Collapse
Affiliation(s)
- David Bento
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Raquel O Rodrigues
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- LCM-Laboratory of Catalysis and Materials-Associate Laboratory LSRE/LCM, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Vera Faustino
- MEMS-UMinho Research Unit, Universidade do Minho, DEI, Campus de Azurém, 4800-058 Guimarães, Portugal.
| | - Diana Pinho
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
| | - Carla S Fernandes
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - Ana I Pereira
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
- Centro de Investigação em Digitalização e Robótica Inteligente (CeDRI), Instituto Politécnico de Bragança, Campus de Santa Apolónia, 5300-253 Bragança, Portugal.
- Algoritmi R&D Centre, Campus de Gualtar, University of Minho, 4710-057 Braga, Portugal.
| | - Valdemar Garcia
- Instituto Politécnico de Bragança, ESTiG/IPB, C. Sta. Apolónia, 5301-857 Bragança, Portugal.
| | - João M Miranda
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
| | - Rui Lima
- CEFT, Faculdade de Engenharia da Universidade do Porto (FEUP) Rua Roberto Frias, 4800-058 Porto, Portugal.
- MEtRiCS, Mechanical Engineering Department, Campus de Azurém, University of Minho, 4800-058 Guimarães, Portugal.
| |
Collapse
|
24
|
Mehri R, Niazi E, Mavriplis C, Fenech M. An automated method for dynamic red blood cell aggregate detection in microfluidic flow. Physiol Meas 2018; 39:01NT02. [PMID: 29227278 DOI: 10.1088/1361-6579/aaa0ad] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Red blood cell (RBC) aggregation is a unique phenomenon that occurs when red blood cells are subjected to low shear rates. Little is known about the sizes, shapes and behaviour of aggregates flowing in healthy humans. However, excessive aggregation has been shown to be an indication of pathological conditions. Therefore, characterizing RBC aggregates is important to medical research. The objective of this study was to develop a reliable technique based on image processing to assess and characterize human RBC aggregation subjected to controlled and measurable shear rates in a two-fluid flow microfluidic shearing system. APPROACH Images of RBC suspensions at [Formula: see text], [Formula: see text] and [Formula: see text] entrained by a phosphate buffered saline solution in a PDMS microchannel were captured with a high speed camera. An algorithm for processing the RBC aggregate images is presented and validated (1) on a sample of known diameter hollow glass microspheres and (2) by comparing RBC aggregate size results with those of an ImageJ image processing technique and those obtained by manual detection by two independent researchers. MAIN RESULTS The proposed image processing algorithm provides a very good agreement with the manufacturer data for the glass microspheres. It also performs well on the RBC suspension images, with errors of 2-4 [Formula: see text] with respect to the manual results. SIGNIFICANCE The proposed automated method for RBC aggregate detection is found to be reliable and fairly accurate and will serve researchers and, perhaps in the future, clinicians to assess healthy and pathological RBC aggregation under flowing conditions.
Collapse
Affiliation(s)
- R Mehri
- Author to whom any correspondence should be addressed
| | | | | | | |
Collapse
|