1
|
AHANDOUST SINA, SAADATMAND MARYAM. COMPUTATIONAL STUDY OF GEOMETRIC EFFECTS OF BOTTOM WALL MICROGROOVES ON CELL DOCKING INSIDE MICROFLUIDIC DEVICES. J MECH MED BIOL 2021. [DOI: 10.1142/s0219519421500172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Cells docking inside microfluidic devices is effective in studying cell biology, cell-based biosensing, as well as drug screening. Furthermore, single cell and regularly cells docking inside the microstructure of microfluidic systems are advantageous in different analyses of single cells exposed to equal drug concentration and mechanical stimulus. In this study, we investigated bottom wall microgrooves with semicircular and rectangular geometries with different sizes which are suitable for single cell docking along the length of the microgroove in [Formula: see text]-direction and numerous cells docking regularly in one line inside the microgroove in a 3D microchannel. We used computational fluid dynamics to analyze the fluid recirculation area inside different microgrooves. The height of recirculation area in the bottom of microgroove could affect the cell’s attachment, and also materials delivery to attached cells, so the height of recirculation area may have optimum value. In addition, we analyzed the fluid drag force on cell movement toward the microgroove. This parameter was proportional to the fluid velocities in [Formula: see text] and [Formula: see text] directions in different microgrooves geometries. In different microgrooves’ geometries the fluid velocity in [Formula: see text]-direction did not change, but the fluid velocity in [Formula: see text]-direction decreased inside the microgroove. Therefore, the cell movement time inside the microgroove increased, and also the drag force in [Formula: see text]-direction could push the cells toward the bottom due to the lower drag force in [Formula: see text]-direction. The percentages of negative shear stress and average shear stress on the adhered cell surface were also calculated. The lower average shear stress, and negative shear stress around 50% on the cell surface were against cell detachment from the substrate. The results indicated that at the constant fluid inlet velocity and microchannel height, microgroove geometry and ratio of cell size to the microgroove size play pivotal roles in the cell initial adhesion to the substrate as well as the cell detachment.
Collapse
Affiliation(s)
- SINA AHANDOUST
- Department of Biomedical Engineering, Amirkabir University of Technology, 424 Hafez Avenue, Tehran, Iran
| | - MARYAM SAADATMAND
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Azadi Avenue, Tehran, Iran
| |
Collapse
|
2
|
Loo JFC, Ho HP, Kong SK, Wang TH, Ho YP. Technological Advances in Multiscale Analysis of Single Cells in Biomedicine. ACTA ACUST UNITED AC 2019; 3:e1900138. [PMID: 32648696 DOI: 10.1002/adbi.201900138] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2019] [Revised: 07/25/2019] [Indexed: 12/20/2022]
Abstract
Single-cell analysis has recently received significant attention in biomedicine. With the advances in super-resolution microscopy, fluorescence labeling, and nanoscale biosensing, new information may be obtained for the design of cancer diagnosis and therapeutic interventions. The discovery of cellular heterogeneity further stresses the importance of single-cell analysis to improve our understanding of disease mechanism and to develop new strategies for disease treatment. To this end, many studies are exploited at the single-cell level for high throughput, highly parallel, and quantitative analysis. Technically, microfluidics are also designed to facilitate single-cell isolation and enrichment for downstream detection and manipulation in a robust, sensitive, and automated manner. Further achievements are made possible by consolidating optically label-free, electrical, and molecular sensing techniques. Moreover, these technologies are coupled with computing algorithms for high throughput and automated quantitative analysis with a short turnaround time. To reflect on how the technological developments have advanced single-cell analysis, this mini-review is aimed to offer readers an introduction to single-cell analysis with a brief historical development and the recent progresses that have enabled multiscale analysis of single-cells in the last decade. The challenges and future trends are also discussed with the view to inspire forthcoming technical developments.
Collapse
Affiliation(s)
- Jacky Fong-Chuen Loo
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR.,Biochemistry Programme, School of Life Sciences, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR
| | - Ho Pui Ho
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR
| | - Siu Kai Kong
- Biochemistry Programme, School of Life Sciences, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR
| | - Tza-Huei Wang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA.,Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD, 21218, USA
| | - Yi-Ping Ho
- Department of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR.,Centre for Novel Biomaterials, The Chinese University of Hong Kong, Shatin, New Territories, Hong Kong SAR
| |
Collapse
|
3
|
Wang C, Ren L, Liu W, Wei Q, Tan M, Yu Y. Fluorescence quantification of intracellular materials at the single-cell level by an integrated dual-well array microfluidic device. Analyst 2019; 144:2811-2819. [PMID: 30882810 DOI: 10.1039/c9an00153k] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We present an integrated microfluidic device for quantifying intracellular materials at the single-cell level. This device combines a dual-well structure and a microfluidic control system. The dual-well structure includes capture wells (20 μm in diameter) for trapping a single cell and reaction wells (200 μm in diameter) for confining reagents. The control system enables a programmable procedure for single-cell analysis. This device achieves highly efficient trapping of single cells, overcoming the Poisson distribution, while affording sufficient biochemical reagents for each isolated reactor. We successfully utilized the presented device to monitor the catalytic interaction between intracellular alkaline phosphatase enzyme and a fluorogenic substrate and to quantify the intracellular glucose concentration of a single K562 cell based on an external standard method. The results demonstrate the feasibility and convenience of our dual-well array microfluidic device as a practical single-cell research tool.
Collapse
Affiliation(s)
- Chenyu Wang
- State Key Laboratory on Integrated Optoelectronics, Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083, China
| | | | | | | | | | | |
Collapse
|