Zhou Y, Pree S, Bellan PM. Imaging suprathermal x-rays from a laboratory plasma jet using PIN-diode-based and scintillator-based 1D pinhole/coded aperture cameras. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2023; 94:013504. [PMID: 36725608 DOI: 10.1063/5.0122760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 12/22/2022] [Indexed: 06/18/2023]
Abstract
A PIN-diode-based 1D x-ray camera and a scintillator-based 1D x-ray camera, both with a microsecond to submicrosecond time resolution, have been developed to perform time-resolved imaging of transient, low-intensity, suprathermal x-rays associated with magnetohydrodynamic instabilities disrupting a plasma jet. These cameras have a high detection efficiency over a broad x-ray band, a wide field of view, and the capability to produce >50 time-resolved frames with a ≤1 μs time resolution. The x-ray images are formed by a pinhole or by a coded aperture placed outside a vacuum chamber in which the plasma jet is launched. The 1D imaging shows that the location of the x-ray source is either a few centimeters away from an inner disk electrode or near a spatially translatable metal frame that is 30-40 cm away from the electrode. Compared to a pinhole, a coded aperture increases the signal collection efficiency but also introduces unwanted artifacts.
Collapse
Affiliation(s)
- Yi Zhou
- Department of Applied Physics and Materials Science, California Institute of Technology, Pasadena, California 91125, USA
| | - Seth Pree
- Department of Applied Physics and Materials Science, California Institute of Technology, Pasadena, California 91125, USA
| | - Paul M Bellan
- Department of Applied Physics and Materials Science, California Institute of Technology, Pasadena, California 91125, USA
| |
Collapse
|
2
|
Barbui T, Chellai O, Delgado-Aparicio L, Ellis R, Hill K, Stratton B, Wallace J, Wisniewski J, Cantone B, Dumont R, Fedorczak N, Hatchressian J, Lotte P, Malard P. Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak. FUSION ENGINEERING AND DESIGN 2021. [DOI: 10.1016/j.fusengdes.2021.112957] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
3
|
Delgado-Aparicio LF, VanMeter P, Barbui T, Chellai O, Wallace J, Yamazaki H, Kojima S, Almagari AF, Hurst NC, Chapman BE, McCollam KJ, Den Hartog DJ, Sarff JS, Reusch LM, Pablant N, Hill K, Bitter M, Ono M, Stratton B, Takase Y, Luethi B, Rissi M, Donath T, Hofer P, Pilet N. Multi-energy reconstructions, central electron temperature measurements, and early detection of the birth and growth of runaway electrons using a versatile soft x-ray pinhole camera at MST. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:073502. [PMID: 34340413 DOI: 10.1063/5.0043672] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Accepted: 04/26/2021] [Indexed: 06/13/2023]
Abstract
A multi-energy soft x-ray pinhole camera has been designed, built, and deployed at the Madison Symmetric Torus to aid the study of particle and thermal transport, as well as MHD stability physics. This novel imaging diagnostic technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently on each pixel. The detector of choice is a PILATUS3 100 K with a 450 μm thick silicon sensor and nearly 100 000 pixels sensitive to photon energies between 1.6 and 30 keV. An ensemble of cubic spline smoothing functions has been applied to the line-integrated data for each time-frame and energy-range, obtaining a reduced standard-deviation when compared to that dominated by photon-noise. The multi-energy local emissivity profiles are obtained from a 1D matrix-based Abel-inversion procedure. Central values of Te can be obtained by modeling the slope of the continuum radiation from ratios of the inverted radial emissivity profiles over multiple energy ranges with no a priori assumptions of plasma profiles, magnetic field reconstruction constraints, high-density limitations, or need of shot-to-shot reproducibility. In tokamak plasmas, a novel application has recently been tested for early detection, 1D imaging, and study of the birth, exponential growth, and saturation of runaway electrons at energies comparable to 100 × Te,0; thus, early results are also presented.
Collapse
Affiliation(s)
| | - P VanMeter
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - T Barbui
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - O Chellai
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - J Wallace
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - H Yamazaki
- National Institutes for Quantum and Radiological Science and Technology, Naka, Ibaraki 311-0193, Japan
| | - S Kojima
- Kyushu University, Kasuga-kouen 6-1, Kasuga, Japan
| | - A F Almagari
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - N C Hurst
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - B E Chapman
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - K J McCollam
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - D J Den Hartog
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - J S Sarff
- University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - L M Reusch
- Edgewood College, Madison, Wisconsin 53711, USA
| | - N Pablant
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - K Hill
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - M Bitter
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - M Ono
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - B Stratton
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - Y Takase
- The University of Tokyo, Kashiwa 277-8561, Japan
| | - B Luethi
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - M Rissi
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - T Donath
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - P Hofer
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - N Pilet
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| |
Collapse
|
4
|
VanMeter PD, Delgado-Aparicio LF, Reusch LM, Den Hartog DJ. Robust analysis of space-, time-, and energy-resolved soft x-ray measurements of magnetically confined fusion plasmas (invited). THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:053549. [PMID: 34243280 DOI: 10.1063/5.0043787] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/11/2021] [Accepted: 04/03/2021] [Indexed: 06/13/2023]
Abstract
A novel compact multi-energy soft x-ray (ME-SXR) diagnostic based on the PILATUS3 100K x-ray detector has been developed in collaboration between the Princeton Plasma Physics Laboratory and the University of Wisconsin-Madison and tested on the Madison Symmetric Torus (MST) reversed-field pinch. This solid-state photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the lower photon absorption cutoff energy can be independently set, allowing it to be configured for a unique combination of simultaneous spatial, spectral, and temporal resolution of ∼1 cm, 100 eV, and 500 Hz, respectively. The diagnostic is highly versatile and can be readily adapted to diverse plasma operating conditions and scientific needs without any required downtime. New results from improved-confinement and quasi-single helicity plasmas in the MST demonstrate how the detector can be applied to study multiple aspects of the evolution of magnetically confined fusion-grade plasmas. These include observing the evolution of thermal emissivity, characterizing the energy of mid-Z excitation lines, extracting the Te profile, and observing the evolution of non-thermal populations. A technique for integrating the ME-SXR diagnostic into an integrated data analysis framework based on Bayesian inference is also presented. This allows ME-SXR measurements to be combined with data for complementary diagnostics in order to simultaneously infer Te and nZ from all available information.
Collapse
Affiliation(s)
- P D VanMeter
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | | | - L M Reusch
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - D J Den Hartog
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| |
Collapse
|
5
|
Barbui T, Delgado-Aparicio LF, Pablant N, Disch C, Luethi B, Pilet N, Stratton B, VanMeter P. Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2021; 92:023105. [PMID: 33648134 DOI: 10.1063/5.0040571] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2020] [Accepted: 01/20/2021] [Indexed: 06/12/2023]
Abstract
A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ∼100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (∼1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV-100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of Kα emission lines are fit to the characteristic responsivity ("S-curve"), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ∼100k pixels. This work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV-10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.
Collapse
Affiliation(s)
- T Barbui
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | | | - N Pablant
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - C Disch
- DECTRIS Ltd., 5405 Baden-Daettwil, Switzerland
| | - B Luethi
- DECTRIS Ltd., 5405 Baden-Daettwil, Switzerland
| | - N Pilet
- DECTRIS Ltd., 5405 Baden-Daettwil, Switzerland
| | - B Stratton
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - P VanMeter
- Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| |
Collapse
|
6
|
Förster A, Brandstetter S, Schulze-Briese C. Transforming X-ray detection with hybrid photon counting detectors. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2019; 377:20180241. [PMID: 31030653 PMCID: PMC6501887 DOI: 10.1098/rsta.2018.0241] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/27/2019] [Indexed: 05/22/2023]
Abstract
Hybrid photon counting (HPC) detectors have radically transformed basic research at synchrotron light sources since 2006. They excel at X-ray diffraction applications in the energy range from 2 to 100 keV. The main reasons for their superiority are the direct detection of individual photons and the accurate determination of scattering and diffraction intensities over an extremely high dynamic range. The detectors were first adopted in macromolecular crystallography where they revolutionized data collection. They were soon also used for small-angle scattering, coherent scattering, powder X-ray diffraction, spectroscopy and increasingly high-energy applications. Here, we will briefly survey the history of HPC detectors, explain their technology and then show in detail how improved detection has transformed a wide range of experimental techniques. We will end with an outlook to the future, which will probably see HPC technology find even broader use, for example, in electron microscopy and medical applications. This article is part of the theme issue 'Fifty years of synchrotron science: achievements and opportunities'.
Collapse
|
7
|
Yamazaki H, Delgado-Aparicio LF, Groebner R, Grierson B, Hill K, Pablant N, Stratton B, Efthimion P, Ejiri A, Takase Y, Ono M. A computational tool for simulation and design of tangential multi-energy soft x-ray pin-hole cameras for tokamak plasmas. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10G120. [PMID: 30399783 DOI: 10.1063/1.5038788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2018] [Accepted: 07/12/2018] [Indexed: 06/08/2023]
Abstract
A new tool has been developed to calculate the spectral, spatial, and temporal responses of multi-energy soft x-ray (ME-SXR) pinhole cameras for arbitrary plasma densities (n e,D), temperature (T e), and impurity densities (n Z). ME-SXR imaging provides a unique opportunity for obtaining important plasma properties (e.g., T e, n Z, and Z eff) by measuring both continuum and line emission in multiple energy ranges. This technique employs a pixelated x-ray detector in which the lower energy threshold for photon detection can be adjusted independently. Simulations assuming a tangential geometry and DIII-D-like plasmas (e.g., n e,0 ≈ 8 × 1019 m-3 and T e,0 ≈ 2.8 keV) for various impurity (e.g., C, O, Ar, Ni, and Mo) density profiles have been performed. The computed brightnesses range from few 102 counts pixel-1 ms-1 depending on the cut-off energy thresholds, while the maximum allowable count rate is 104 counts pixel-1 ms-1. The typical spatial resolution in the mid-plane is ≈0.5 cm with a photon-energy resolution of 500 eV at a 500 Hz frame rate.
Collapse
Affiliation(s)
- H Yamazaki
- The University of Tokyo, Kashiwa 277-8561, Japan
| | | | - R Groebner
- General Atomics, San Diego, California 92121, USA
| | - B Grierson
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - K Hill
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - N Pablant
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - B Stratton
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - P Efthimion
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| | - A Ejiri
- The University of Tokyo, Kashiwa 277-8561, Japan
| | - Y Takase
- The University of Tokyo, Kashiwa 277-8561, Japan
| | - M Ono
- Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540, USA
| |
Collapse
|
8
|
VanMeter P, Delgado-Aparicio LF, Reusch L, Pablant N, Maddox J, Rissi M, Luethi B, Donath T, Schulze-Briese C, Hill K, Den Hartog D. Pixel-to-pixel variation on a calibrated PILATUS3-based multi-energy soft x-ray detector. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2018; 89:10G119. [PMID: 30399863 DOI: 10.1063/1.5037347] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Accepted: 06/04/2018] [Indexed: 06/08/2023]
Abstract
A multi-energy soft x-ray pin-hole camera based on the PILATUS3 100 K x-ray detector has recently been installed on the Madison Symmetric Torus. This photon-counting detector consists of a two-dimensional array of ∼100 000 pixels for which the photon lower-threshold cutoff energy E c can be independently set for each pixel. This capability allows the measurement of plasma x-ray emissivity in multiple energy ranges with a unique combination of spatial and spectral resolution and the inference of a variety of important plasma properties (e.g., T e, n Z, Z eff). The energy dependence of each pixel is calibrated for the 1.6-6 keV range by scanning individual trimbit settings, while the detector is exposed to fluorescence emission from Ag, In, Mo, Ti, V, and Zr targets. The resulting data for each line are then fit to a characteristic "S-curve" which determines the mapping between the 64 possible trimbit settings for each pixel. The statistical variation of this calibration from pixel-to-pixel was explored, and it was found that the discreteness of trimbit settings results in an effective threshold resolution of ΔE < 100 eV. A separate calibration was performed for the 4-14 keV range, with a resolution of ΔE < 200 eV.
Collapse
Affiliation(s)
- P VanMeter
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | | | - L Reusch
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - N Pablant
- Princeton Plasma Physics Laboratory (PPPL), Princeton, New Jersey 08540, USA
| | - J Maddox
- Department of Engineering Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| | - M Rissi
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - B Luethi
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | - T Donath
- DECTRIS Ltd., 5405 Baden-Dättwil, Switzerland
| | | | - K Hill
- Princeton Plasma Physics Laboratory (PPPL), Princeton, New Jersey 08540, USA
| | - D Den Hartog
- Department of Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA
| |
Collapse
|