1
|
Chen M, Pei Z, Wang Y, Song F, Zhong J, Wang C, Ma Y. Small extracellular vesicles' enrichment from biological fluids using an acoustic trap. Analyst 2024; 149:3169-3177. [PMID: 38639189 DOI: 10.1039/d4an00034j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/20/2024]
Abstract
Small extracellular vesicles (sEVs), a form of extracellular vesicles, are lipid bilayered structures released by all cells. Large-scale studies on sEVs from clinical samples are necessary, but a major obstacle is the lack of rapid, reproducible, efficient, and low-cost methods to enrich sEVs. Acoustic microfluidics have the advantage of being label-free and biocompatible, which have been reported to successfully enrich sEVs. In this paper, we present a highly efficient acoustic microfluidic trap that can offer low and large volume compatible ways of enriching sEVs from biological fluids by flexible structure design. It uses the idea of pre-loading larger seed particles in the acoustic trap to enable sub-micron particle capturing. The microfluidic chip is actuated using a piezoelectric plate transducer attached to a silicon-glass bonding plate with circular cavities. Each cavity works as a resonant unit, excited at the frequency of both the half wave resonance in the main plane and inverted quarter wave resonance in the depth direction, which has the ability to strongly trap seed particles at the center, thereby improving the subsequent nanoparticle capture efficiency. Mean trapping efficiencies of 35.62% and 64.27% were obtained using 60 nm and 100 nm nanobeads, respectively. By the use of this technology, we have successfully enriched sEVs from cell culture conditioned media and blood plasma at a flow rate of 10 μL min-1. The isolated sEV subpopulations are characterized by NTA and TEM, and their protein cargo is determined by WB. This acoustic trapping chip provides a rapid and robust method to enrich sEVs from biofluids with high reproducibility and sufficient quantities. Therefore, it can serve as a new tool for biological and clinical research such as cancer diagnosis and drug delivery.
Collapse
Affiliation(s)
- Mengli Chen
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Zhiguo Pei
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Yao Wang
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Feifei Song
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Jinfeng Zhong
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Ce Wang
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| | - Yuting Ma
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
| |
Collapse
|
2
|
Nair KPPR, Veettil TCP, Wood BR, Paul D, Alan T. Haemoprocessor: A Portable Platform Using Rapid Acoustically Driven Plasma Separation Validated by Infrared Spectroscopy for Point-of-Care Diagnostics. BIOSENSORS 2022; 12:bios12020119. [PMID: 35200379 PMCID: PMC8924765 DOI: 10.3390/bios12020119] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2021] [Revised: 02/04/2022] [Accepted: 02/10/2022] [Indexed: 05/28/2023]
Abstract
The identification of biomarkers from blood plasma is at the heart of many diagnostic tests. These tests often need to be conducted frequently and quickly, but the logistics of sample collection and processing not only delays the test result, but also puts a strain on the healthcare system due to the sheer volume of tests that need to be performed. The advent of microfluidics has made the processing of samples quick and reliable, with little or no skill required on the user's part. However, while several microfluidic devices have been demonstrated for plasma separation, none of them have validated the chemical integrity of the sample post-process. Here, we present Haemoprocessor: a portable, robust, open-fluidic system that utilizes Travelling Surface Acoustic Waves (TSAW) with the expression of overtones to separate plasma from 20× diluted human blood within a span of 2 min to achieve 98% RBC removal. The plasma and red blood cell separation quality/integrity was validated through Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy and multivariate analyses to ascertain device performance and reproducibility when compared to centrifugation (the prevailing gold-standard for plasma separation). Principal Component Analysis (PCA) showed a remarkable separation of 92.21% between RBCs and plasma components obtained through both centrifugation and Haemoprocessor methods. Moreover, a close association between plasma isolates acquired by both approaches in PCA validated the potential of the proposed system as an eminent cell enrichment and plasma separation platform. Thus, compared to contemporary acoustic devices, this system combines the ease of operation, low sample requirement of an open system, the versatility of a SAW device using harmonics, and portability.
Collapse
Affiliation(s)
- Kamal Prakash Prasanna Ravindran Nair
- Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia;
- Department of Biosciences & Bioengineering, Indian Institute of Technology Bombay, Mumbai 400076, India;
- IIT Bombay—Monash Academy, Indian Institute of Technology Bombay, Mumbai 400076, India
| | | | - Bayden R. Wood
- Monash Centre for Biospectroscopy, Department of Chemistry, Monash University, Melbourne, VIC 3800, Australia; (T.C.P.V.); (B.R.W.)
| | - Debjani Paul
- Department of Biosciences & Bioengineering, Indian Institute of Technology Bombay, Mumbai 400076, India;
- IIT Bombay—Monash Academy, Indian Institute of Technology Bombay, Mumbai 400076, India
| | - Tuncay Alan
- Department of Mechanical & Aerospace Engineering, Monash University, Melbourne, VIC 3800, Australia;
- IIT Bombay—Monash Academy, Indian Institute of Technology Bombay, Mumbai 400076, India
| |
Collapse
|
3
|
Wang C, Ma Y, Pei Z, Song F, Zhong J, Wang Y, Yan X, Dai P, Jiang Y, Qiu J, Shi M, Wu X. Sheathless acoustic based flow cell sorter for enrichment of rare cells. Cytometry A 2021; 101:311-324. [PMID: 34806837 DOI: 10.1002/cyto.a.24521] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2021] [Revised: 11/12/2021] [Accepted: 11/17/2021] [Indexed: 11/12/2022]
Abstract
Cell enrichment is a powerful tool in many kinds of cell research, especially in applications with low abundance cell types. In this work, we developed a microfluidic fluorescence activated cell sorting device that was able to perform on-demand, low loss cell detection, and sorting. The chip utilizes three-dimensional acoustic standing waves to position all cells in the same fluid velocity regime without sheath. When the cells pass through a laser interrogation region, the scattering and fluorescent signals are detected, translated and transported to software. The target cells are then identified by gating on the plots. Short bursts of standing acoustic waves are triggered by order from PC to sort target cells within predefined gating region. For very low abundance and rare labeled lymphocytes mixed with high concentration unlabeled white blood cells (WBCs), (1-100 labeled lymphocytes are diluted in 106 WBCs in 1 ml volume fluid), the device is able to remove more than 98% WBCs and recover labeled lymphocytes with efficiency of 80%. We further demonstrated that this device worked with real clinical samples by successfully isolating fetal nucleated red blood cells (FNRBCs) in the blood samples from pregnant women with male fetus. The obtained cells were sequenced and the expressions of (sex determining region Y) SRY genes were tested to determine fetal cell proportion. In genetic analysis, the proportion of fetal cells in the final picked sample is up to 40.64%. With this ability, the device proposed could be valuable for biomedical applications involving fetal cells, circulating tumor cells, and stem cells.
Collapse
Affiliation(s)
- Ce Wang
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.,CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Yuting Ma
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Zhiguo Pei
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Feifei Song
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Jinfeng Zhong
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Yao Wang
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Xintao Yan
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Pu Dai
- Department of Otolaryngology, Head and Neck Surgery, Institute of Otolaryngology, Chinese PLA General Hospital, Beijing, China
| | - Yi Jiang
- Department of Otolaryngology-Head and Neck Surgery, Shanghai ninth people's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.,Ear Institute, Shanghai JiaoTong University School of Medicine, Shanghai, China
| | - Jianping Qiu
- Department of Obstetrics and Gynecology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, China
| | - Mengdie Shi
- Department of Obstetrics and Gynecology, The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, China
| | - Xiaodong Wu
- School of Biomedical Engineering (Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Hefei, China.,CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| |
Collapse
|
4
|
Wang C, Ma Y, Chen Z, Wu Y, Song F, Qiu J, Shi M, Wu X. Sheathless microflow cytometer utilizing two bulk standing acoustic waves. Cytometry A 2021; 99:987-998. [PMID: 33956400 DOI: 10.1002/cyto.a.24362] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 04/26/2021] [Accepted: 04/30/2021] [Indexed: 01/16/2023]
Abstract
In recent years, microflow cytometry has become a popular research field because of its potential to provide low-cost and disposable chips for complex cell analyses. Herein, we demonstrate a sheathless microflow cytometer which integrates a bulk standing acoustic wave based microchip capable of three dimensional cell focusing. Flow cytometry was successfully demonstrated using this system with a coefficient of variation (CV) of 2.16% with standard calibration beads. The sensitivities calibrated by rainbow beads are 518 MEFL in fluorescein Isothiocyanate (FITC) channel and 264 MEPE in P-phycoerythrin (PE) channels, respectively. The linearities are more than 99% in both channels. The capability of the proposed microflow cytometer is further demonstrated by immunologically labeled leukocytes differentiation in blood. This acoustic-based microflow cytometer did not require any sheath flows or complex structures and can be mass produced. Because of the simple fluid channel, the chip can be easily made pipeless, disposable for applications requiring no cross contamination. Moreover, with the gentle and bio-compatible acoustic waves used, this technique is expected to maintain the viability of cells and other bioparticles.
Collapse
Affiliation(s)
- Ce Wang
- School of Biomedical Engineering(Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China.,CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Yuting Ma
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Zhongxiang Chen
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Yunliang Wu
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Feifei Song
- CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| | - Jianping Qiu
- The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China
| | - Mengdie Shi
- The Affiliated Suzhou Hospital of Nanjing Medical University, Suzhou Municipal Hospital, Gusu School, Nanjing Medical University, Suzhou, Jiangsu, China
| | - Xiaodong Wu
- School of Biomedical Engineering(Suzhou), Division of Life Sciences and Medicine, University of Science and Technology of China, Suzhou, Jiangsu, China.,CAS Key Lab of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu, China
| |
Collapse
|