1
|
Honig ML, Haba A, O'Leary KMF, Robinson EEA, Madungwe KV, Lin Y, McGuire C, Bühlmann P. Improvement of the Upper Detection Limit of Ionophore-Based H +-Selective Electrodes: Explanation and Elimination of Apparently Super-Nernstian Responses. Anal Chem 2024; 96:9901-9908. [PMID: 38850234 DOI: 10.1021/acs.analchem.4c00984] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/10/2024]
Abstract
The response range of an ion-selective electrode (ISE) has been described by counterion interference at the lower and Donnan failure at the upper detection limit. This approach fails when the potentiometric response at the upper detection limit exhibits an apparently super-Nernstian response, as has been reported repeatedly for H+-selective electrodes. While also observed when samples contain other anions, super-Nernstian responses at low pH are a problem in particular for samples that contain phthalate, a common component of commercial pH calibration solutions. This work shows that coextraction of H+ and a sample anion into the sensing membrane alone does not explain these super-Nernstian responses, even when membrane-internal diffusion potentials are taken into account. Instead, these super-Nernstian responses are explained by the formation of complexes between that anion and at least two protonated ionophore molecules. As demonstrated by experiments and explained with quantitative phase boundary models, the apparently super-Nernstian responses at low pH can be eliminated by restricting the molecular ratio of ionophore and ionic sites. Notably, this conclusion results in recommendations for the optimization of sensing membranes that, in some instances, will conflict with previously reported recommendations from the ionic site theory for the optimization of the lower detection limit. This mechanistic insight is key to maximizing the response range of these ionophore-based ISEs.
Collapse
Affiliation(s)
- Madeline L Honig
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Ariki Haba
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Katie M F O'Leary
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Emily E A Robinson
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Kuzivakwashe V Madungwe
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| | - Ye Lin
- Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States
| | - Chad McGuire
- Emerson Automation Solutions, 6021 Innovation Boulevard, Shakopee, Minnesota 55379, United States
| | - Philippe Bühlmann
- Department of Chemistry, University of Minnesota, 207 Pleasant Street, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
2
|
Chen XV, Mousavi MP, Bühlmann P. Fluorous-Phase Ion-Selective pH Electrodes: Electrode Body and Ionophore Optimization for Measurements in the Physiological pH Range. ACS OMEGA 2020; 5:13621-13629. [PMID: 32566827 PMCID: PMC7301372 DOI: 10.1021/acsomega.0c00582] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2020] [Accepted: 05/18/2020] [Indexed: 06/11/2023]
Abstract
Because of their low polarity and polarizability, fluorous sensing membranes are both hydrophobic and lipophobic and exhibit very high ion selectivities. Here, we report on a new fluorous-membrane ion-selective electrode (ISE) with a wide sensing range centered around physiologically relevant pH values. The fluorophilic tris[perfluoro(octyl)butyl]amine (N[(CH2)4Rf8]3) was synthesized and tested as a new H+ ionophore using a redesigned electrode body that provides excellent mechanical sealing and much improved measurement reliability. In a challenging 1 M KCl background, these fluorous-phase ISEs exhibit a sensing range from pH 2.2 to 11.2, which is one of the widest working ranges reported to date for ionophore-based H+ ISEs. High selectivities against common interfering ions such as K+, Na+, and Ca2+ were determined (selectivity coefficients: logK H, K pot = - 11.6; logK H, Na pot = - 12.4; logK H, Ca pot < - 10.2). The use of the N[(CH2)4Rf8]3 ionophore with its -(CH2)4- spacers separating the amino group from the strongly electron-withdrawing perfluorooctyl groups improved the potentiometric selectivity as compared to the less basic tris[perfluoro(octyl)propyl]amine ionophore. The use of N[(CH2)4Rf8]3 also made the ISE less prone to counter anion failure (i.e., Donnan failure) at low pH than the use of tris[perfluoro(octyl)pentyl]amine with its longer -(CH2)5- spacers, which more effectively shield the amino center from the perfluorooctyl groups. In addition, we exposed both conventional plasticized PVC-phase pH ISEs and fluorous-phase pH ISEs to 10% serum for 5 days. Results show that the PVC-phase ISEs lost selectivity while their fluorous-phase counterparts did not.
Collapse
|
3
|
Jasielec JJ, Mousavi Z, Granholm K, Sokalski T, Lewenstam A. Sensitivity and Selectivity of Ion-Selective Electrodes Interpreted Using the Nernst-Planck-Poisson Model. Anal Chem 2018; 90:9644-9649. [DOI: 10.1021/acs.analchem.8b02659] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Jerzy J. Jasielec
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Physical Chemistry and Modeling Department, Al. Mickiewicza 30, 30-059 Kraków, Poland
| | - Zekra Mousavi
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Kim Granholm
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Tomasz Sokalski
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| | - Andrzej Lewenstam
- AGH University of Science and Technology, Faculty of Materials Science and Ceramics, Physical Chemistry and Modeling Department, Al. Mickiewicza 30, 30-059 Kraków, Poland
- Johan Gadolin Process Chemistry Centre, c/o Centre for Process Analytical Chemistry and Sensor Technology (ProSens), Åbo Akademi University, Biskopsgatan 8, 20500 Åbo-Turku, Finland
| |
Collapse
|
4
|
Sahani MK, Singh AK, Jain AK. Nano-level monitoring of Mn(2+) ion by fabrication of coated pyrolytic graphite electrode based on isonicotinohydrazide derivatives. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 50:124-32. [PMID: 25746253 DOI: 10.1016/j.msec.2015.01.091] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/25/2014] [Revised: 01/16/2015] [Accepted: 01/30/2015] [Indexed: 10/24/2022]
Abstract
The two ionophores N'(N',N‴E,N',N‴E)-N',N‴-((((oxybis(ethane-2,1-diyl))bis(oxy)) bis(2,1-phenylene))bis(methanylylidene))di(isonicotinohydrazide) (I1) and (N',N‴E,N',N‴E)-N',N‴-(((propane-1,3-diylbis(oxy))bis(2,1-phenylene))bis(methanylylidene))di(isonicotinohydrazide) (I2) were synthesised and investigated as neutral carrier in the fabrication of Mn(2+) ion selective sensor. Several membranes were prepared by incorporating different plasticizers and anionic excluders and their effect on potentiometric response was studied. The best analytical performance was obtained with the electrode having a membrane of composition of I2: PVC: o-NPOE: NaTPB in the ratio of 6:34:58:2 (w/w, mg). Comparative studies of coated graphite electrode (CGE) and coated pyrolytic graphite electrode (CPGE) based on I2 reveal the superiority of CPGE. The CPGE exhibits wide working concentration range of 1.23×10(-8)-1.0×10(-1) mol L(-1) and a detection limit down to 4.78×10(-9) mol L(-1) with a Nernstian slope of 29.5±0.4 mV decade(-1) of activity. The sensor performs satisfactorily over a wide pH range (3.5-9.0) and exhibited a quick response time (9s). The sensor can work satisfactorily in water-acetonitrile and water-methanol mixtures. It can tolerate 30% acetonitrile and 20% methanol content in the mixtures. The sensor could be used for a period of four months without any significant divergence in performance. The sensor reflects its utility in the quantification of Mn(2+) ion in real samples and has been successfully employed as an indicator electrode in the potentiometric titration of Mn(2+) ion with ethylenediaminetetraacetic acid (EDTA).
Collapse
Affiliation(s)
- Manoj Kumar Sahani
- Department of Chemistry, Indian Institute of Technology-Roorkee, Rookee 247667, India
| | - A K Singh
- Department of Chemistry, Indian Institute of Technology-Roorkee, Rookee 247667, India.
| | - A K Jain
- Department of Chemistry, Indian Institute of Technology-Roorkee, Rookee 247667, India
| |
Collapse
|
5
|
WITHDRAWN: PVC membrane based of 2,3,5-Triphenyltetrazolium Chloride (TTC) and 2,4,5-Triphenyltetrazolium Formazan (TTF) for determination Ba2+ and its application of crystal growth. ARAB J CHEM 2013. [DOI: 10.1016/j.arabjc.2013.11.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
6
|
Su CC, Ueng CH, Liu LK. Characteristics of Lariat Crown Ether-Copper (II) Ion-Selective Electrodes. J CHIN CHEM SOC-TAIP 2013. [DOI: 10.1002/jccs.200100105] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
7
|
Wang TY, Shih JS. Iron (III) Ion Selective Electrode Based on Dithia 12-Crown-4. J CHIN CHEM SOC-TAIP 2013. [DOI: 10.1002/jccs.198800060] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
8
|
Mercury selective potentiometric sensor based on low rim functionalized thiacalix [4]-arene as a cationic receptor. J Mol Liq 2013. [DOI: 10.1016/j.molliq.2012.10.008] [Citation(s) in RCA: 333] [Impact Index Per Article: 30.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
9
|
Mazloum-Ardakani M, Manshadi AD, Bagherzadeh M, Kargar H. Impedimetric and Potentiometric Investigation of a Sulfate Anion-Selective Electrode: Experiment and Simulation. Anal Chem 2012; 84:2614-21. [DOI: 10.1021/ac203260e] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
| | | | - Mojtaba Bagherzadeh
- Waste
Management Department, NFCRS, Nuclear Science and Technology Research Institute,
Isfahan, 81465-1589, I. R. Iran
| | - Hadi Kargar
- Departmentof Chemistry, Payame Noor University, P.O. Box 19395-4697
Tehran, I. R. Iran
| |
Collapse
|
10
|
Singh J, Singh AK, Jain A. Fabrication of novel coated graphite electrodes for the selective nano-level determination of Cd2+ ions in biological and environmental samples. Electrochim Acta 2011. [DOI: 10.1016/j.electacta.2011.06.106] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
11
|
Yang Y, Cao X, Surowiec M, Bartsch RA. Calix[4]arene-dithiacrown ethers: synthesis and potentiometric membrane sensing of Hg2+. Tetrahedron 2010. [DOI: 10.1016/j.tet.2009.11.058] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
12
|
Zook JM, Lindner E. Reverse current pulse method to restore uniform concentration profiles in ion-selective membranes. 1. Galvanostatic pulse methods with decreased cycle time. Anal Chem 2009; 81:5146-54. [PMID: 19459603 DOI: 10.1021/ac801984d] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
The applications of ion-selective electrodes (ISEs) have been broadened through the introduction of galvanostatic current pulse methods in potentiometric analysis. An important requirement in these applications is the restoration of the uniform equilibrium concentration profiles in the ISE membrane between each measurement. The simplest restoration method is zero-current relaxation, in which the membrane relaxes under open-circuit conditions in a diffusion-controlled process. This paper presents a novel restoration method using a reverse current pulse. An analytic model for this restoration method is derived to predict the concentration profiles inside ISE membranes following galvanostatic current pulses. This model allows the calculation of the voltage transients as the membrane voltage relaxes back toward its zero-current equilibrium value. The predicted concentration profiles and voltage transients are confirmed using spectroelectrochemical microscopy (SpECM). The reverse current restoration method described in this paper reduces the voltage drift and voltage error by 10-100 times compared to the zero-current restoration method. Therefore, this new method provides faster and more reproducible voltage measurements in most chronopotentiometric ISE applications, such as improving the detection limit and determining concentrations and diffusion coefficients of membrane species. One limitation of the reverse current restoration method is that it cannot be used in a few applications that require background electrolyte loaded membranes without excess of lipophilic cation exchanger.
Collapse
Affiliation(s)
- Justin M Zook
- Department of Biomedical Engineering, The University of Memphis, 330 Engineering Technology Building, Memphis, Tennessee 38152, USA
| | | |
Collapse
|
13
|
Egorov V, Lyaskovski P, Il'inchik I, Soroka V, Nazarov V. Estimation of Ion-Pairing Constants in Plasticized Poly(vinyl chloride) Membranes Using Segmented Sandwich Membranes Technique. ELECTROANAL 2009. [DOI: 10.1002/elan.200904639] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Nano-level monitoring of Yb(III) by fabrication of coated graphite electrode based on newly synthesized hexaaza macrocyclic ligand. Anal Chim Acta 2009; 643:74-82. [DOI: 10.1016/j.aca.2009.03.047] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2009] [Revised: 03/26/2009] [Accepted: 03/27/2009] [Indexed: 11/18/2022]
|
15
|
Gupta VK, Goyal RN, Jain AK, Sharma RA. Aluminium (III)-selective PVC membrane sensor based on a Schiff base complex of N,N′-bis (salicylidene)-1, 2-cyclohexanediamine. Electrochim Acta 2009. [DOI: 10.1016/j.electacta.2008.11.020] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
16
|
Singh AK, Singh P, Banerjee S, Mehtab S. Development of electrochemical sensors for nano scale Tb(III) ion determination based on pendant macrocyclic ligands. Anal Chim Acta 2009; 633:109-18. [DOI: 10.1016/j.aca.2008.11.029] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2008] [Revised: 11/12/2008] [Accepted: 11/13/2008] [Indexed: 10/21/2022]
|
17
|
Mazloum Ardakani M, Ebrahimi P, Mansournia MR. The complex (2,3;6,7;10,11;14,15-tetraphenyl-4,9,13,16-tetraoxo-1,5,8,12-tetraazacyclohexadecane) copper(II) as a carrier for a salicylate-sensitive poly(vinylchloride) membrane electrode. RUSS J ELECTROCHEM+ 2008. [DOI: 10.1134/s1023193508090127] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
18
|
|
19
|
Performance evaluation criteria for preparation and measurement of macro- and microfabricated ion-selective electrodes (IUPAC Technical Report). PURE APPL CHEM 2008. [DOI: 10.1351/pac200880010085] [Citation(s) in RCA: 179] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Over the last 30 years, IUPAC published several documents with the goal of achieving standardized nomenclature and methodology for potentiometric ion-selective electrodes (ISEs). The ISE vocabulary was formulated, measurement protocols were suggested, and the selectivity coefficients were compiled. However, in light of new discoveries and experimental possibilities in the field of ISEs, some of the IUPAC recommendations have become outdated. The goal of this technical report is to direct attention to ISE practices and the striking need for updated or refined IUPAC recommendations which are consistent with the state of the art of using macro- and microfabricated planar microelectrodes. Some of these ISE practices have never been addressed by IUPAC but have gained importance with the technological and theoretical developments of recent years. In spite of its recognized importance, a generally acceptable revision of the current IUPAC recommendations is far beyond the scope of this work.
Collapse
|
20
|
Abstract
Potentiometric sensors share unique characteristics that set them apart from other electrochemical sensors. Potentiometric nanoelectrodes have been reported and successfully used for many decades, and we review these developments. Current research chiefly focuses on nanoscale films at the outer or the inner side of the membrane, with outer layers for increasing biocompatibility, expanding the sensor response, or improving the limit of detection (LOD). Inner layers are mainly used for stabilizing the response and eliminating inner aqueous contacts or undesired nanoscale layers of water. We also discuss the ultimate detectability of ions with such sensors and the power of coupling the ultra-low LODs of ion-selective electrodes with nanoparticle labels to give attractive bioassays that can compete with state-of-the-art electrochemical detection.
Collapse
Affiliation(s)
- Eric Bakker
- Nanochemistry Research Institute, Department of Applied Chemistry, Curtin University of Technology, Perth, WA 6845, Australia
| | - Ernö Pretsch
- Institute of Biogeochemistry and Pollutant Dynamics, ETH Zurich, CH-8092 Zurich, Switzerland
| |
Collapse
|
21
|
Mazloum Ardakani M, Pourhakak P, Salavati-Niasari M. Bis(2-hydroxyacetophenone)ethylenediimine as a neutral carrier in a coated-wire membrane electrode for lead(II). ANAL SCI 2007; 22:865-70. [PMID: 16772687 DOI: 10.2116/analsci.22.865] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A coated-wire ion-selective electrode (CWISE), based on a Schiff base as a neutral carrier, was successfully developed for the detection of Pb(II) in aqueous solution. CWISE exhibited a linear response with a Nernstian slope of 29.4 +/- 0.5 mV/decade within the concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M lead ion. CWISE has shown detection limits of 5.0 x 10(-6) M. The electrode exhibited good selectivity over a number of alkali, alkaline earth, transition and heavy metal ions. This sensor yielded a steady potential within 10 to 20 s at a linear dynamic range. The electrode was suitable for use in aqueous solutions in a pH range of 2.0 to 5.0. Applications of this electrode for the determination of lead in real samples and as indicator electrode for potentiometric titration of Pb2+ ion using K2CrO4 are reported.
Collapse
|
22
|
Kumar KG, Poduval R, Augustine P, John S, Saraswathyamma B. A PVC plasticized sensor for Ni(II) ion based on a simple ethylenediamine derivative. ANAL SCI 2007; 22:1333-7. [PMID: 17038772 DOI: 10.2116/analsci.22.1333] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6-7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.
Collapse
|
23
|
|
24
|
Singh AK, Mehtab S, Jain AK. Selective electrochemical sensor for copper (II) ion based on chelating ionophores. Anal Chim Acta 2006; 575:25-31. [PMID: 17723567 DOI: 10.1016/j.aca.2006.05.076] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2006] [Revised: 05/17/2006] [Accepted: 05/22/2006] [Indexed: 11/24/2022]
Abstract
Plasticized membranes using 3-(2-pyridinyl)-2H-pyrido[1,2,-a]-1,3,5-triazine-2,4(3H)-dithione (L1) and acetoacetanilide (L2) have been prepared and explored as Cu2+-selective sensors. Effect of various plasticizers, viz. chloronaphthalene (CN), benzyl acetate (BA), o-nitrophenyloctyl ether (o-NPOE), and anion excluders, sodium tetraphenylborate (NaTPB) and oleic acid (OA) was studied in detail and improved performance was observed at several instances. Optimum performance was observed with dithione derivative (L1) having a membrane composition of L1 (5):PVC (120):o-NPOE (240):OA (10). The sensor works satisfactorily in the concentration range 5.0 x 10(-8) to 1.0 x 10(-2) M (detection limit 4.0 x 10(-8) M) with a Nernstian slope of 29.5 mV decade(-1) of activity. Wide pH range (3.0-9.5), fast response time (12s), non-aqueous tolerance (up to 20%) and adequate shelf life (4 months) indicate the vital utility of the proposed sensor. The potentiometric selectivity coefficient values as determined by match potential method (MPM) indicate good response for Cu2+ in presence of interfering ions. The proposed electrode comparatively shows good selectivity with respect to alkali, alkaline earth, transition and some rare earth metals ions. The electrode was used for the determination of copper in different milk powder, water samples and as indicator electrode in potentiometric titration of copper ion with EDTA.
Collapse
Affiliation(s)
- Ashok Kumar Singh
- Department of Chemistry, Indian Institute of Technology at Roorkee, Roorkee 247667, India.
| | | | | |
Collapse
|
25
|
|
26
|
Mohamed SK. Ion-selective electrode for gallium determination in nickel alloy, fly-ash and biological samples. Anal Chim Acta 2006. [DOI: 10.1016/j.aca.2006.01.014] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
27
|
Ardakani MM, Jalayer M, Naeimi H, Heidarnezhad A, Zare HR. Highly selective oxalate-membrane electrode based on 2,2′-[1,4-butandiyle bis(nitrilo propylidine)]bis-1-naphtholato copper(II). Biosens Bioelectron 2006; 21:1156-62. [PMID: 15925504 DOI: 10.1016/j.bios.2005.04.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2005] [Revised: 04/26/2005] [Accepted: 04/26/2005] [Indexed: 11/27/2022]
Abstract
A new oxalate-selective electrode based on the complex 2,2'-[1,4-butandiyle bis(nitrilo propylidine)]bis-1-naphtholato copper(II) (CuL) as the membrane carrier was developed. The electrode exhibited a good Nernstian slope of -29.2+/-0.6 mV/decade (mean value+/-standard deviation, n=5) and a linear range of 5.0 x 10(-8) to 1.0 x 10(-1)M for oxalate. The limit of detection was 5.0 x 10(-8)M. This electrode represents a fast response time (i.e. 10-15s) and could be used for more than 3 months. The selectivity coefficients were determined by the fixed interference method (FIM) and could be used in the pH range of 2.0-7.0. It was employed as an indicator electrode for the determination of oxalate in water samples.
Collapse
Affiliation(s)
- M Mazloum Ardakani
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
| | | | | | | | | |
Collapse
|
28
|
Ardakani MM, Jalayer MS, Safari J, Sadeghi Z, Zare HR. Salicylate poly(vinyl chloride) membrane electrode based on (2-[(E)-2-(4-nitrophenyl) hydrazono]-1-phenyl-2-(2-quinolyl)-1-ethanone) Cu(II). Anal Biochem 2005; 341:259-66. [PMID: 15907871 DOI: 10.1016/j.ab.2005.03.040] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2004] [Indexed: 10/25/2022]
Abstract
A new salicylate-selective electrode based on the complex of (2-[(E)-2-(4-nitrophenyl)hydrazono]-1-phenyl-2-(2-quinolyl)-1-ethanone) Cu(II) as the membrane carrier was developed. The electrode exhibited a good Nernstian slope of -59.6+/-1.0 mV/decade and a linear range of 1.0 x 10(-6) to 1.0M for salicylate. The limit of detection was 5.0 x 10(-7) M. The electrode had a fast response time of 10 s and can be used for more than 3 months. The selective coefficients were determined by the fixed interference method and could be used in the pH range of 4.0 to 10.5. The electrode was employed as an indicator electrode for direct determination of salicylate in pharmaceutical and biological samples.
Collapse
Affiliation(s)
- M Mazloum Ardakani
- Department of Chemistry, Faculty of Science, Yazd University, Yazd, Iran.
| | | | | | | | | |
Collapse
|
29
|
Xu L, Yuan R, Fu YZ, Chai YQ. Potentiometric Membrane Electrode for Salicylate Based on an Organotin Complex with a Salicylal Schiff Base of Amino Acid. ANAL SCI 2005; 21:287-92. [PMID: 15790114 DOI: 10.2116/analsci.21.287] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A novel salicylate-selective electrode based on an organotin complex with a salicylal Schiff base of amino acid salicylaldehydeaminoacid-di-n-butyl-Sn(IV) [Sn(IV)-SAADB] as ionophore is described, which exhibits high selectivity for salicylate over many other common anions with an anti-Hofmeister selectivity sequence: Sal- >> PhCOO- > SCN- > Cl04- > I- > NO3- > NO2- > Br- > Cl- > CH3COO-. The electrode, based on Sn(IV)-SAADB, with a 30.44 wt% PVC, a 65.45 wt% plasticizer (dioctyl phthalate, DOP), a 3.81 wt% ionophore and a 0.3 wt% anionic additive is linear in 6.0 x 10(-6) - 1.0 x 10(-1) mol l(-1) with a detection limit of 2.0 x 10(-6) mol l(-1) and a slope of 62.0 +/- 1.2 mV/decade of salicylate concentration in a phosphate buffer solution of pH 5.5 at 25 degrees C. The influence on the electrode performances by lipophilic charged additives was studied, and the possible response mechanism was investigated by UV spectra. The electrode was applied to medicine analysis and the result obtained has been satisfactory.
Collapse
Affiliation(s)
- Lan Xu
- Institute of Analytical Chemistry, The College of Chemistry and Chemical Engineering, Southwest China Normal University, Chongqing 400715, PR China
| | | | | | | |
Collapse
|
30
|
Bissig R, Oesch U, Pretsch E, Morf WE, Simon W. Einfluss der Lipophilie von 3, 6-Dioxakorksäurediamiden auf ihr Verhalten als Ionophore. Helv Chim Acta 2004. [DOI: 10.1002/hlca.19780610504] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
31
|
Bissig R, Pretsch E, Morf WE, Simon W. Makrocyclische und acyclische neutrale Ionophore. Einfluss des Ringschlusses auf die Kationenselektivität. Helv Chim Acta 2004. [DOI: 10.1002/hlca.19780610503] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
32
|
Büchi R, Pretsch E, Morf WE, Simon W. 13C-Kernresonanzspektroskopische und elektromotorische Untersuchungen der Wechselwirkung von neutralen Carriern mit Ionen in Membranen. Helv Chim Acta 2004. [DOI: 10.1002/hlca.19760590715] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
33
|
Shahrokhian S, Taghani A, Hamzehloei A, Reza Mousavi S. Potentiometric membrane sensors based on zirconyl(IV) phthalocyanine for detection of sulfosalicylic acid. Talanta 2004; 63:371-6. [DOI: 10.1016/j.talanta.2003.11.007] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2003] [Revised: 10/19/2003] [Accepted: 11/05/2003] [Indexed: 11/24/2022]
|
34
|
Johnson RD, Bachas LG. Ionophore-based ion-selective potentiometric and optical sensors. Anal Bioanal Chem 2003; 376:328-41. [PMID: 12734632 DOI: 10.1007/s00216-003-1931-0] [Citation(s) in RCA: 115] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2002] [Revised: 03/15/2003] [Accepted: 03/20/2003] [Indexed: 10/20/2022]
Abstract
This paper describes ion-selective electrodes (ISEs) and optodes with a focus on the fundamental mechanisms, response characteristics, and recognition elements (ionophores) described to date for these sensors. The topics covered review the most frequently encountered ideas about ionophore-based sensors, including the theoretical and experimental parameters that influence response, typical ionophore structures, useful membrane compositions, and applications. Since these sensors are applicable in a number of fields, such as clinical, environmental, and process monitoring, as well as more novel approaches such as microfluidic-based systems and micro/nanoprobes, this article provides descriptions that are oriented toward a more general audience. Furthermore, a large portion of this review describes the ionophore component itself in hopes of inspiring ideas in readers of how novel molecular architectures with new ionic targets or improved selectivity can be developed.
Collapse
Affiliation(s)
- R Daniel Johnson
- Department of Chemistry, University of Kentucky, Lexington 40505-0055, USA
| | | |
Collapse
|
35
|
Lo CK, Choi MM. Symmetrical electrochemical cell for determination of coextraction constants of metal salts for ion-selective polymeric membranes. Anal Chim Acta 2003. [DOI: 10.1016/s0003-2670(03)00420-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
36
|
Arida HA, el-Reefy SA, el-Saied AM. A new lead(II)-selective PVC-coated graphite rod electrode based on a Schiff base complex. ANAL SCI 2003; 19:687-90. [PMID: 12769365 DOI: 10.2116/analsci.19.687] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A new lead(II)-selective electrode has been developed based on bis(acetylacetone)-p-phenylenediamine-lead(II) [LPb(NO3)2]H2O complex ionophore as a sensing material, dioctylphthalate (DOP) as a solvent mediator and PVC as a matrix. This electrode exhibits a linear Nernstian response over the concentration range of 1 x 10(-5)-1 x 10(-1) mol l(-1) of Pb(II) cation, with a cationic calibration slope of 30.0 +/- 0.2 mV/concentration decade and a detection limit of 2 x 10(-6) mol l(-1) (0.40 ppm). It has a fast response time and can be used for a period of 2 months without any divergence in potentials. The proposed electrode reveals a good selectivity for Pb(II) over a wide variety of other tested cations and could be used in the pH range of 4-8. It was successfully used for direct determination of Pb(II) concentration in some samples. The obtained results show a good agreement with those obtained by an atomic absorption spectrometric method. The average recovery obtained is 96.5 +/- 0.5% with standard deviation of 1.2% (n = 8).
Collapse
Affiliation(s)
- Hassan A Arida
- Hot Lab. Center, Atomic Energy Authority, 13759-Cairo, Egypt.
| | | | | |
Collapse
|
37
|
|
38
|
Qin Y, Bakker E. Evaluation of the separate equilibrium processes that dictate the upper detection limit of neutral ionophore-based potentiometric sensors. Anal Chem 2002; 74:3134-41. [PMID: 12141674 DOI: 10.1021/ac0156159] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The upper detection limit of polar ionophore-based ion-selective electrode membranes is predicted by utilizing the coextraction constant of dissociated electrolyte, the stability constant of the ionophore, and the membrane composition. The coextraction constant of dissociated electrolytes into the polar poly(vinyl chloride) membrane plasticized with o-nitrophenyl octyl ether (PVC-NPOE) is here measured by a novel approach. The sandwich membrane technique is utilized, with one membrane segment containing a lipophilic cation exchanger and the other containing an anion exchanger. This yields information about the coextraction constant and the free ion concentrations of the electrolyte in the two segments. Predictions correlate quantitatively with the upper detection limit observed for ion-selective electrodes based on the ionophores valinomycin, tert-butylcalix[4]arene tetraethyl ester, and calcimycin. The difficulties of the prediction of the upper detection limit for nonpolar poly(vinyl chloride) membranes plasticized with bis(2-ethylhexyl sebacate) (PVC-DOS) due to ion association are discussed in detail. A thermodynamic cycle experiment with a series of sandwich membranes shows that the principal processes governing the upper detection limit of PVC-DOS membranes are identical to those for the PVC-NPOE membranes. However, the stability of the ion pairs between the ionophore-metal ion complexes and the extracted anion are different from that of ion pairs formed between the same anion and the lipophilic anion exchanger. This makes it difficult to quantitatively predict the upper detection limit on the basis of simple apparent coextraction and complexation data alone. The approach reported herein is useful not only for mechanistic purposes but also to shed light onto the many cases where coextraction effects need to be understood but are not directly experimentally accessible.
Collapse
Affiliation(s)
- Yu Qin
- Department of Chemistry, Auburn University, Alabama 36849, USA
| | | |
Collapse
|
39
|
|
40
|
Mazloum M, Salavati Niassary M, Mirhoseini Chahooki S, Amini M. Silver-Selective Coated-Wire Electrode Based on Resorc[4]arene Neutral Carrier. ELECTROANAL 2002. [DOI: 10.1002/1521-4109(200203)14:5<376::aid-elan376>3.0.co;2-m] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
41
|
Szymańska I, Ocicka K, Radecka H, Radecki J, Geise H, Dieltiens P, Aleksandrzak K. Methoxy-substituted derivatives of 1,4-bis(2-phenylethenyl)benzene and of 1,4-bis(2-phenylethyl)benzene as ligands in ion-selective electrodes for lead ions. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2001. [DOI: 10.1016/s0928-4931(01)00348-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
42
|
Panwar A, Baniwal S, Singh R, Sharma CL, Singh AK. STRONTIUM (II)-SELECTIVE ELECTRODE BASED ON A MACROCYCLIC LIGAND. ANAL LETT 2001. [DOI: 10.1081/al-100107523] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
43
|
Radecka H, Tohda K, Umezawa Y. Optimum concentration of anionic sites in lipophilic macrocyclic pentaamine-based liquid membranes for potentiometric responses to anionic analytes. ANAL SCI 2001; 17:1221-4. [PMID: 11990601 DOI: 10.2116/analsci.17.1221] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- H Radecka
- Polish Academy of Sciences, Institute of Animal Reproduction and Food Science, Division of Food Research, Olsztyn
| | | | | |
Collapse
|
44
|
Qin Y, Bakker E. Quantification of the concentration of ionic impurities in polymeric sensing membranes with the segmented sandwich technique. Anal Chem 2001; 73:4262-7. [PMID: 11569818 DOI: 10.1021/ac0104126] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Ionic impurities in solvent polymeric membranes have been the main reason early ion-selective electrodes (ISEs) without added ion exchanger exhibited a functional potentiometric response. Today, knowledge of such impurities and their elimination becomes important in view of designing ISEs with low detection limits and voltammetric ion-selective electrodes, to increase operational lifetime, and to optimize sensing selectivity. Here, a potentiometric segmented sandwich membrane technique is used to study the amount and properties of impurities in situ directly in the membrane phase. This technique can be used with a number of ionophores and with different membrane matrixes and does not require specialized equipment. The concentration of anionic impurities in PVC-DOS (bis(2-ethylhexyl) sebacate) and PVC-NPOE (o-nitrophenyloctyl ether) was found to be on the order of 100 micromol/kg with membranes containing weakly binding potassium ionophores. The concentration of cation-exchanger sites of carboxylated PVC-NPOE was found to be higher (1.62 mmol/kg). Addition of the neutral lipophilic salt ETH 500 to both membrane segments had only a marginal effect on the results for PVC-NPOE membranes but had a large impact on the observed membrane potential for PVC-DOS membranes. Theory explains that the addition of such salt to membranes where ion pairing is predominant is essential for the accurate assessment of ionic impurities with this technique.
Collapse
Affiliation(s)
- Y Qin
- Department of Chemistry, Auburn University, Alabama 36849, USA
| | | |
Collapse
|
45
|
Tohda K, Higuchi T, Dragoe D, Umezawa Y. Threshold ionic site concentrations required for Nernstian potentiometric responses of neutral ionophore-incorporated ion-selective liquid membranes. ANAL SCI 2001; 17:833-9. [PMID: 11708115 DOI: 10.2116/analsci.17.833] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
An equation that can describe the concentrations of ionic sites required for a Nernstian potentiometric response slope of neutral ionophore-incorporated ion-selective liquid membranes is presented. This equation is derived from a model based on electrical diffuse layers on both the membrane and the aqueous sides of the interface, in which the phase boundary potential is correlated to the surface charge density as well as the salt concentrations in the bulk membrane and aqueous solution. To experimentally and accurately confirm the validity of this equation, response characteristics of field effect transistors covered by neutral ionophore-based liquid membranes with varying concentrations of a derivative of tetraphenylborate as an anionic site but free of ionic impurities were examined. The observed membrane potentials and the response slopes for membranes with various concentrations of anionic sites were in good agreement with the values calculated from the theory presented in this paper with the measured complexation stability constants for the relevant systems. This result indicates that the theoretical prediction based on the proposed equation for the anionic site concentration is accessible for the preparation of neutral ionophore-incorporated ion-selective liquid membranes, which show Nernstian response slopes for the primary ions.
Collapse
Affiliation(s)
- K Tohda
- Department of Chemistry, School of Science, University of Tokyo, Hongo, Bunkyo, Tokyo 113-0033, Japan
| | | | | | | |
Collapse
|
46
|
|
47
|
|
48
|
Umezawa K, Tohda K, Lin XM, Sessler JL, Umezawa Y. Expanded porphyrin incorporated solvent polymeric membrane electrodes: protonation and interaction with an analyte anion at organic/water interface as studied by optical second harmonic generation and Fourier transform infrared attenuated total reflectance spectrometry. Anal Chim Acta 2001. [DOI: 10.1016/s0003-2670(00)01157-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
49
|
Gupta K. Effect of concentration of ion exchanger, plasticizer and molecular weight of cyanocopolymers on selectivity and sensitivity of Cd(II) ion selective electrode. Talanta 2000; 52:1087-103. [DOI: 10.1016/s0039-9140(00)00479-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/1999] [Revised: 05/30/2000] [Accepted: 05/31/2000] [Indexed: 11/26/2022]
|
50
|
Chen L, He X, Zhao B, Liu Y. Calixarene derivative as the neutral carrier in silver ion-selective electrode and liquid membrane transport. Anal Chim Acta 2000. [DOI: 10.1016/s0003-2670(00)00912-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|