1
|
Zhang T, Abdelhamid SA, Li D, Zhang H. A hydrogel-modified electrochemical biosensor for the rapid detection of ammonia‑nitrogen-resistant bacteria. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 932:172828. [PMID: 38692312 DOI: 10.1016/j.scitotenv.2024.172828] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2023] [Revised: 04/03/2024] [Accepted: 04/25/2024] [Indexed: 05/03/2024]
Abstract
Ammonia‑nitrogen wastewater is one of the main pollutants in the current environment. Rapid detection of microorganisms resistant to ammonia‑nitrogen provides a basis for bioremediation of ammonia‑nitrogen contaminated sites. This study uses electrochemical analysis for efficiently detecting of ammonia-resistant bacteria, utilizing a commercially available, low-cost screen-printed electrode (SPE) modified with agarose-based hydrogel (gel) or graphene oxide (GO). At the same time, the study employed electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV) to monitor bacterial growth, revealing Escherichia coli (E. coli) inhibition upon ammonia‑nitrogen addition, while Raoultella terrigena (RN1) and Pseudomonas (RN2) exhibit tolerance. The method provides sensitivity results in <45 min, which is significantly faster than traditional methods. RN1 and RN2 exhibit promising ammonia‑nitrogen removal rates, reaching up to 81 % and 92 %, respectively. This study aimed to develop an effective electrochemical method for rapidly detecting the sensitivity of microorganisms to ammonia‑nitrogen. The method offers advantages such as high speed, efficiency, and cost-effectiveness, potentially providing valuable microbial resources for mitigating ammonia nitrogen wastewater pollution.
Collapse
Affiliation(s)
- Ting Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China
| | | | - Defeng Li
- State Key Laboratory of Microbial Resources, Institute of Microbiology, Chinese Academy of Sciences, Beijing 100101, China.
| | - Houjin Zhang
- Department of Biotechnology, College of Life Science and Technology, Huazhong University of Science and Technology, MOE Key Laboratory of Molecular Biophysics, Wuhan 430074, China.
| |
Collapse
|
2
|
Graphene-Based Biosensors for Molecular Chronic Inflammatory Disease Biomarker Detection. BIOSENSORS 2022; 12:bios12040244. [PMID: 35448304 PMCID: PMC9030187 DOI: 10.3390/bios12040244] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/08/2022] [Revised: 04/04/2022] [Accepted: 04/11/2022] [Indexed: 11/17/2022]
Abstract
Chronic inflammatory diseases, such as cancer, diabetes mellitus, stroke, ischemic heart diseases, neurodegenerative conditions, and COVID-19 have had a high number of deaths worldwide in recent years. The accurate detection of the biomarkers for chronic inflammatory diseases can significantly improve diagnosis, as well as therapy and clinical care in patients. Graphene derivative materials (GDMs), such as pristine graphene (G), graphene oxide (GO), and reduced graphene oxide (rGO), have shown tremendous benefits for biosensing and in the development of novel biosensor devices. GDMs exhibit excellent chemical, electrical and mechanical properties, good biocompatibility, and the facility of surface modification for biomolecular recognition, opening new opportunities for simple, accurate, and sensitive detection of biomarkers. This review shows the recent advances, properties, and potentialities of GDMs for developing robust biosensors. We show the main electrochemical and optical-sensing methods based on GDMs, as well as their design and manufacture in order to integrate them into robust, wearable, remote, and smart biosensors devices. We also describe the current application of such methods and technologies for the biosensing of chronic disease biomarkers. We also describe the current application of such methods and technologies for the biosensing of chronic disease biomarkers with improved sensitivity, reaching limits of detection from the nano to atto range concentration.
Collapse
|
3
|
Pothipor C, Bamrungsap S, Jakmunee J, Ounnunkad K. A gold nanoparticle-dye/poly(3-aminobenzylamine)/two dimensional MoSe 2/graphene oxide electrode towards label-free electrochemical biosensor for simultaneous dual-mode detection of cancer antigen 15-3 and microRNA-21. Colloids Surf B Biointerfaces 2021; 210:112260. [PMID: 34894598 DOI: 10.1016/j.colsurfb.2021.112260] [Citation(s) in RCA: 31] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2021] [Revised: 11/25/2021] [Accepted: 12/02/2021] [Indexed: 12/11/2022]
Abstract
A dual-mode electrochemical biosensor is successfully developed for simultaneous detection of two different kinds of breast cancer biomarkers, namely cancer antigen 15-3 (CA 15-3) and microRNA-21 (miRNA-21), for the first time. The sensor composes of a poly(3-aminobenzylamine)/two-dimensional (2D) molybdenum selenide/graphene oxide nanocomposite modified two-screen-printed carbon electrode array (dual electrode), functionalized individually with 2,3-diaminophenazine-gold nanoparticles and toluidine blue-gold nanoparticles. Both kinds of the redox probe-gold nanoparticles are employed as signaling molecules and supports for immobilization of anti-CA 15-3 antibodies and capture DNA-21 probes, respectively. Due to the good conductivity and high surface-to-volume ratio of the nanocomposite, high amount of the antibodies and capture probes can be immobilized on the modified dual-electrode, giving the efficient duplex detection. Consequently, the biosensor provides good selectivity, and high sensitivity for the dual target analyte detection. The experimental results show that this label-free biosensor exhibits good linear responses to the concentrations of both target analytes with the limits of detection (LODs) of 0.14 U mL-1 and 1.2 fM for CA 15-3 and miRNA-21, respectively. This assay strategy has a great potential to be further developed for the simultaneous detection of a variety of miRNAs and protein biomarkers for point-of-care (POC) diagnostic applications.
Collapse
Affiliation(s)
- Chammari Pothipor
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; The Graduate School, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Suwussa Bamrungsap
- National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai 50200, Thailand.
| |
Collapse
|
4
|
Yaiwong P, Semakul N, Bamrungsap S, Jakmunee J, Ounnunkad K. Electrochemical detection of matrix metalloproteinase-7 using an immunoassay on a methylene blue/2D MoS 2/graphene oxide electrode. Bioelectrochemistry 2021; 142:107944. [PMID: 34500138 DOI: 10.1016/j.bioelechem.2021.107944] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2021] [Revised: 08/25/2021] [Accepted: 08/26/2021] [Indexed: 02/08/2023]
Abstract
Methylene blue (MB) adsorption onto a two-dimensional molybdenum disulfide (2D MoS2)/graphene oxide (GO) nanocomposite sitting on a screen-printed carbon electrode (SPCE) is used to develop a new sensitive label-free electrochemical immunosensor for the detection of matrix metalloproteinase-7 (MMP-7) cancer biomarkers. The 2D MoS2/GO nanocomposite deposited onto an SPCE provides a large specific surface area, fast electron transfer, and exceptional electrical conductivity. Furthermore, MB adsorbed onto the 2D MoS2/GO nanocomposite architecture can be used for signal amplification in electrochemical immunosensors. Moreover, an immunosensor platform was fabricated by the adsorption of anti-MMP-7 capture antibodies onto the MB/2D MoS2/GO nanocomposite surface via electrostatic interactions for the detection of the MMP-7 immunocomplex. Under optimum conditions, the label-free immunosensor exhibits a decrease in the current response for MB corresponding to the MMP-7 concentration. The sensor affords a linear logarithmic range of 0.010-75 ng mL-1 with a limit of detection (LOD) of 0.007 ng mL-1. The developed electrochemical immunosensor provides high selectivity, good reproducibility, and excellent stability. Furthermore, the proposed immunosensor can be applied for the detection of MMP-7 in human serum samples with good recovery. Thus, this device can be applied for the early clinical diagnosis of pancreatic and colorectal cancers.
Collapse
Affiliation(s)
- Patrawadee Yaiwong
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; The Graduate School, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Natthawat Semakul
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Suwussa Bamrungsap
- National Nanotechnology Center (NANOTEC), National Science and Technology Development Agency (NSTDA), Pathum Thani 12120, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai 50200, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand; Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai 50200, Thailand; Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai 50200, Thailand.
| |
Collapse
|
5
|
Critical reviews of electro-reactivity of screen-printed nanocomposite electrode to safeguard the environment from trace metals. MONATSHEFTE FUR CHEMIE 2021. [DOI: 10.1007/s00706-021-02802-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
6
|
Phetsang S, Khwannimit D, Rattanakit P, Chanlek N, Kidkhunthod P, Mungkornasawakul P, Jakmunee J, Ounnunkad K. A Redox Cu(II)-Graphene Oxide Modified Screen Printed Carbon Electrode as a Cost-Effective and Versatile Sensing Platform for Electrochemical Label-Free Immunosensor and Non-enzymatic Glucose Sensor. Front Chem 2021; 9:671173. [PMID: 34095085 PMCID: PMC8172615 DOI: 10.3389/fchem.2021.671173] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Accepted: 04/14/2021] [Indexed: 11/24/2022] Open
Abstract
A novel copper (II) ions [Cu(II)]-graphene oxide (GO) nanocomplex-modified screen-printed carbon electrode (SPCE) is successfully developed as a versatile electrochemical platform for construction of sensors without an additionally external redox probe. A simple strategy to prepare the redox GO-modified SPCE is described. Such redox GO based on adsorbed Cu(II) is prepared by incubation of GO-modified SPCE in the Cu(II) solution. This work demonstrates the fabrications of two kinds of electrochemical sensors, i.e., a new label-free electrochemical immunosensor and non-enzymatic sensor for detections of immunoglobulin G (IgG) and glucose, respectively. Our immunosensor based on square-wave voltammetry (SWV) of the redox GO-modified electrode shows the linearity in a dynamic range of 1.0-500 pg.mL-1 with a limit of detection (LOD) of 0.20 pg.mL-1 for the detection of IgG while non-enzymatic sensor reveals two dynamic ranges of 0.10-1.00 mM (sensitivity = 36.31 μA.mM-1.cm-2) and 1.00-12.50 mM (sensitivity = 3.85 μA.mM-1.cm-2) with a LOD value of 0.12 mM. The novel redox Cu(II)-GO composite electrode is a promising candidate for clinical research and diagnosis.
Collapse
Affiliation(s)
- Sopit Phetsang
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- National Institute of Technology, Nagaoka College, Niigata, Japan
| | - Duangruedee Khwannimit
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Parawee Rattanakit
- Division of Chemistry, School of Science, Walailak University, Nakhon Si Thammarat, Thailand
| | - Narong Chanlek
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pinit Kidkhunthod
- Synchrotron Light Research Institute (Public Organization), Nakhon Ratchasima, Thailand
| | - Pitchaya Mungkornasawakul
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Environmental Science Research Center, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
| | - Kontad Ounnunkad
- Department of Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, Thailand
- Research Center on Chemistry for Development of Health Promoting Products from Northern Resources, Chiang Mai University, Chiang Mai, Thailand
- Center of Excellence in Materials Science and Technology, Chiang Mai University, Chiang Mai, Thailand
| |
Collapse
|
7
|
Ménard-Moyon C, Bianco A, Kalantar-Zadeh K. Two-Dimensional Material-Based Biosensors for Virus Detection. ACS Sens 2020; 5:3739-3769. [PMID: 33226779 DOI: 10.1021/acssensors.0c01961] [Citation(s) in RCA: 51] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Viral infections are one of the major causes of mortality and economic losses worldwide. Consequently, efficient virus detection methods are crucial to determine the infection prevalence. However, most detection methods face challenges related to false-negative or false-positive results, long response times, high costs, and/or the need for specialized equipment and staff. Such issues can be overcome by access to low-cost and fast response point-of-care detection systems, and two-dimensional materials (2DMs) can play a critical role in this regard. Indeed, the unique and tunable physicochemical properties of 2DMs provide many advantages for developing biosensors for viral infections with high sensitivity and selectivity. Fast, accurate, and reliable detection, even at early infection stages by the virus, can be potentially enabled by highly accessible surface interactions between the 2DMs and the analytes. High selectivity can be obtained by functionalization of the 2DMs with antibodies, nucleic acids, proteins, peptides, or aptamers, allowing for specific binding to a particular virus, viral fingerprints, or proteins released by the host organism. Multiplexed detection and discrimination between different virus strains are also feasible. In this Review, we present a comprehensive overview of the major advances of 2DM-based biosensors for the detection of viruses. We describe the main factors governing the efficient interactions between viruses and 2DMs, making them ideal candidates for the detection of viral infections. We also critically detail their advantages and drawbacks, providing insights for the development of future biosensors for virus detection. Lastly, we provide suggestions to stimulate research in the fast expanding field of 2DMs that could help in designing advanced systems for preventing virus-related pandemics.
Collapse
Affiliation(s)
- Cécilia Ménard-Moyon
- CNRS, Immunology, Immunopathology and Therapeutic Chemistry, UPR3572, University of Strasbourg, ISIS, Strasbourg 67000, France
| | - Alberto Bianco
- CNRS, Immunology, Immunopathology and Therapeutic Chemistry, UPR3572, University of Strasbourg, ISIS, Strasbourg 67000, France
| | - Kourosh Kalantar-Zadeh
- School of Chemical Engineering, University of New South Wales, Kensington, New South Wales 2052, Australia
| |
Collapse
|
8
|
Song Y, Cao K, Li W, Ma C, Qiao X, Li H, Hong C. Optimal film thickness of rGO/MoS2 @ polyaniline nanosheets of 3D arrays for carcinoembryonic antigen high sensitivity detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.104694] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
9
|
Stefan-van Staden RI, Ilie-Mihai RM, Gugoasa LA, Bilasco A, Visan CA, Streinu-Cercel A. Molecular recognition of IL-8, IL-10, IL-12, and IL-15 in biological fluids using phthalocyanine-based stochastic sensors. Anal Bioanal Chem 2018; 410:7723-7737. [PMID: 30255322 DOI: 10.1007/s00216-018-1386-y] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2018] [Revised: 09/11/2018] [Accepted: 09/17/2018] [Indexed: 01/05/2023]
Abstract
Two stochastic sensors based on the modification of graphite paste with the complexes formed by phthalocyanine (PhCN) with Ni and Cu were designed and used for molecular recognition of IL-8, IL-10, IL-12, and IL-15. The four interleukins were recognized according to their signatures-called toff (qualitative parameter) from the diagrams obtained after measurements. The limit of determination for IL-8 was 1 × 10-4μg mL-1 when both stochastic sensors were used; for IL-10, the determination limit was 4.5 × 10-4μg mL-1 for the Ni complex-based sensor, and 4.5 × 10-7μg mL-1 for the Cu complex-based sensor, respectively; for IL-12, the determination limit was 5 × 10-4μg mL-1 for the Ni complex-based sensor, and 5 × 10-7μg mL-1 for the Cu complex-based sensor, respectively; while for IL-15, the determination limit was 5 × 10-5μg/mL for the Ni complex-based sensor, and 5 × 10-5μg/mL for the Cu complex-based sensor, respectively. The stochastic method used was validated using the following biological fluids: nasal lavage, saliva, serum, and whole blood. Graphical abstract ᅟ.
Collapse
Affiliation(s)
- Raluca-Ioana Stefan-van Staden
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021, Bucharest-6, Romania. .,Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, Bucharest, Romania.
| | - Ruxandra M Ilie-Mihai
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021, Bucharest-6, Romania.,Faculty of Applied Chemistry and Material Science, Politehnica University of Bucharest, Bucharest, Romania
| | - Livia Alexandra Gugoasa
- Laboratory of Electrochemistry and PATLAB, National Institute of Research for Electrochemistry and Condensed Matter, 202 Splaiul Independentei Str., 060021, Bucharest-6, Romania
| | - Anuta Bilasco
- National Institute of Infectious Diseases "Prof. Dr. Matei Balș", Carol Davila University of Medicine and Pharmacy, 1 Dr. Calistrat Grozovici St., 021105, Bucharest, Romania
| | - Constanta Angelica Visan
- National Institute of Infectious Diseases "Prof. Dr. Matei Balș", Carol Davila University of Medicine and Pharmacy, 1 Dr. Calistrat Grozovici St., 021105, Bucharest, Romania
| | - Adrian Streinu-Cercel
- National Institute of Infectious Diseases "Prof. Dr. Matei Balș", Carol Davila University of Medicine and Pharmacy, 1 Dr. Calistrat Grozovici St., 021105, Bucharest, Romania
| |
Collapse
|