1
|
Vanella G, Coluccio C, Cucchetti A, Leone R, Dell'Anna G, Giuffrida P, Abbatiello C, Binda C, Fabbri C, Arcidiacono PG. Fully covered versus partially covered self-expandable metal stents for palliation of distal malignant biliary obstruction: a systematic review and meta-analysis. Gastrointest Endosc 2024; 99:314-322.e19. [PMID: 37813199 DOI: 10.1016/j.gie.2023.10.023] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 08/28/2023] [Accepted: 10/04/2023] [Indexed: 10/11/2023]
Abstract
BACKGROUND AND AIMS Self-expandable metal stents (SEMSs) are standardly used for distal malignant biliary obstruction (dMBO). Although data suggest that covered versus uncovered SEMSs increase the time to recurrent biliary obstruction (TRBO), no data are available for fully covered (FC) versus partially covered (PC) designs. METHODS PubMed, Scopus, and Cochrane databases were screened up to January 2023 for studies concerning dMBO treated by an FC- or PC-SEMS and describing adverse events (AEs), recurrences, or TRBO for specific design subpopulations. Pooled proportions or means were calculated using a random-effects model. Several subanalyses were preplanned, including a subanalysis restricted to prospective studies and unresectable diseases. Heterogeneity and publication bias were explored. Standardized differences (d-values) were calculated between groups. RESULTS From 1290 records, 62 studies (3327 using FC-SEMSs and 2322 using PC-SEMSs) were included. FC- versus PC-SEMSs showed negligible differences in the rate of total AEs (12% vs 9.9%) and all specific AEs, including cholecystitis (2.5% vs 2.6%). In a subanalysis restricted to prospective studies and unresectable diseases, the rate of RBO was comparable between FC-SEMSs (27.3% [95% confidence interval {CI}, 23.7-31.2], I2 = 35.34%) and PC-SEMSs (25.3% [95% CI, 20.2-30.7], I2 = 85.09%), despite small differences (d-values between .186 and .216) in the rate of ingrowth (.5% vs 2.9%) favoring FC-SEMSs and migration (9.8% vs 4.3%) favoring PC-SEMSs. TRBO was shorter for FC-SEMSs (238 days [95% CI, 191-286], I2 = 63.1%) versus PC-SEMSs (369 days [95% CI, 290-449], I2 = 71.9%; d-value = .116). CONCLUSIONS Despite considerable heterogeneity and small standardized differences, PC-SEMSs consistently exhibited longer TRBO than FC-SEMSs across analyses, without any other differences in AE rates, potentially proposing PC-SEMSs as the standard comparator and TRBO as the primary outcome for future randomized studies on dMBO. (Clinical trial registration number: CRD42023393965.).
Collapse
Affiliation(s)
- Giuseppe Vanella
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Chiara Coluccio
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Alessandro Cucchetti
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Pancreatobiliary Endoscopy and Endosonography Division, Alma Mater Studiorum University of Bologna, Bologna, Italy
| | - Roberto Leone
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy; International MD Program, Vita-Salute San Raffaele University, Milan, Italy
| | - Giuseppe Dell'Anna
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| | - Paolo Giuffrida
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Section of Gastroenterology & Hepatology, Department of Health Promotion Sciences Maternal and Infant Care, Internal Medicine and Medical Specialties, PROMISE, University of Palermo, Palermo, Italy
| | - Carmela Abbatiello
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy; Digestive Disease Postgraduate School, University of Salerno, Italy
| | - Cecilia Binda
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Carlo Fabbri
- Gastroenterology Department, Morgagni-Pierantoni Hospital, Forlì, Italy
| | - Paolo Giorgio Arcidiacono
- Pancreatobiliary Endoscopy and Endosonography Division, Pancreas Translational and Clinical Research Centre, IRCCS San Raffaele Scientific Institute, Vita-Salute San Raffaele University, Milan, Italy
| |
Collapse
|
2
|
Endo Y, Tanaka M, Kitago M, Yagi H, Abe Y, Hasegawa Y, Hori S, Nakano Y, Iwasaki E, Kitagawa Y. Comparison Between Plastic and Metallic Biliary Stent Placement for Preoperative Patients with Pancreatic Head Cancer: A Systematic Review and Meta-Analysis. Ann Surg Oncol 2024; 31:1319-1327. [PMID: 37952017 DOI: 10.1245/s10434-023-14523-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2023] [Accepted: 10/15/2023] [Indexed: 11/14/2023]
Abstract
BACKGROUND Optimal preoperative biliary drainage for patients with pancreatic cancer before pancreatoduodenectomy remains unclear. This study aimed to investigate the comparison of efficacy and safety between a metallic stent (MS) and a plastic stent (PS). METHODS Comparative studies on the use of MS and PS for pancreatic cancer before pancreatoduodenectomy were systematically searched using the MEDLINE and Web of Science databases. Pre- and postoperative data also were extracted. Random-effects meta-analyses were performed to compare post-endoscopic retrograde cholangiopancreatography (ERCP) complications as well as intra- and postoperative outcomes between the two arms of the study, and pooled odds ratios (ORs) or mean differences (MDs) were calculated with 95 percent confidence intervals (CIs). RESULTS The study analyzed 12 studies involving 683 patients. Insertion of MS was associated with a lower incidence of re-intervention (OR, 0.06; 95% CI 0.03-0.15; P < 0.001), increased post-ERCP adverse events (OR, 2.22; 95% CI 1.13-4.36; P = 0.02), and similar operation time (MD, 18.0 min; 95% CI -29.1 to 65.6 min; P = 0.46), amount of blood loss (MD, 43.0 ml; 95% CI -207.1 to 288.2 ml; P = 0.73), and surgical complication rate (OR, 0.78; 95% CI 0.53-1.15; P = 0.21). The cumulative stent patency rate after 3 months was higher in the MS group than in the PS group (70-100 % vs 30.0-45.0 %). CONCLUSION For biliary drainage in patients with pancreatic cancer during this era of multidisciplinary treatment, MS use might be the first choice because MS provides a more durable biliary drainage and a similar risk of postoperative outcomes compared with PS.
Collapse
Affiliation(s)
- Yutaka Endo
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Masayuki Tanaka
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan.
| | - Minoru Kitago
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Hiroshi Yagi
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yuta Abe
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yasushi Hasegawa
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Shutaro Hori
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yutaka Nakano
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Eisuke Iwasaki
- Departments of Internal Medicine, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| | - Yuko Kitagawa
- Departments of Surgery, Keio University School of Medicine, Shinanomachi, Shinjuku, Tokyo, Japan
| |
Collapse
|