Thiruchelvam N, Hashim H, Forman CR, Jacobsen L, Sperup T, Andersen K. New compact micro-hole zone catheter enables women to achieve effective bladder emptying without flow-stops. BRITISH JOURNAL OF NURSING (MARK ALLEN PUBLISHING) 2024; 33:834-843. [PMID: 39302905 DOI: 10.12968/bjon.2024.0212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/22/2024]
Abstract
BACKGROUND Clean intermittent self-catheterisation (CISC) with conventional eyelet catheters (CECs) is associated with urine flow-stops, which require the catheter to be repositioned so flow can resume. Flow-stops often occur because bladder mucosa is sucked into the eyelets. AIMS This investigation aimed to compare the bladder-emptying performance of the micro-hole zone catheter (MHZC) with the CEC. METHODS This was a multi-centre, randomised, open-label, controlled cross-over study with 82 women comparing the MHZC to the CEC. The endpoints relating to bladder-emptying performance included the residual volume at first flow-stop, the number of flow-stops and the proportion of successful treatment responses. The women's perception of the catheters was assessed as well as device discomfort. FINDINGS Catheterisations with MHZC significantly reduced the risk of flow-stops, with relative risk results showing a 2.74 times lower risk of flow-stops with a health professional-led catheterisation and a 2.52 times lower risk during self-catheterisation. There was no statistical difference in residual urine volume at first flow-stop between the two catheters. Catheterisations with the MHZC were significantly more likely to achieve zero flow-stops and a residual urine volume of <10 ml at first flow-stop. The women had a significantly more positive perception of the MHZC than the CEC in areas including handling, confidence, sensation and satisfaction. CONCLUSION The MHZC enabled effective bladder emptying without catheters needing to be repositioned, supporting the women by simplifying the procedure and making them feel confident that their bladders were empty.
Collapse
Affiliation(s)
- Nikesh Thiruchelvam
- Consultant Urologist, Department of Urology, Addenbrooke's Hospital, Cambridge University Hospitals NHS Foundation Trust, Cambridge, UK
| | - Hashim Hashim
- Consultant Urological Surgeon, Bristol Urological Institute, North Bristol NHS Trust, Bristol, UK
| | | | | | - Trine Sperup
- Clinical Strategy Project Manager, Coloplast, Humlebæk, Denmark
| | - Karin Andersen
- Chief Physician, Department of Urology, Odense University Hospital, Odense, Denmark
| |
Collapse
|
2
|
Prieto JA, Murphy CL, Stewart F, Fader M. Intermittent catheter techniques, strategies and designs for managing long-term bladder conditions. Cochrane Database Syst Rev 2021; 10:CD006008. [PMID: 34699062 PMCID: PMC8547544 DOI: 10.1002/14651858.cd006008.pub5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
BACKGROUND Intermittent catheterisation (IC) is a commonly recommended procedure for people with incomplete bladder emptying. Frequent complications are urinary tract infection (UTI), urethral trauma and discomfort during catheter use. Despite the many designs of intermittent catheter, including different lengths, materials and coatings, it is unclear which catheter techniques, strategies or designs affect the incidence of UTI and other complications, measures of satisfaction/quality of life and cost-effectiveness. This is an update of a Cochrane Review first published in 2007. OBJECTIVES: To assess the clinical and cost-effectiveness of different catheterisation techniques, strategies and catheter designs, and their impact, on UTI and other complications, and measures of satisfaction/quality of life among adults and children whose long-term bladder condition is managed by intermittent catheterisation. SEARCH METHODS We searched the Cochrane Incontinence Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings (searched 12 April 2021), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheterisation techniques, strategies or catheter designs. DATA COLLECTION AND ANALYSIS As per standard Cochrane methodological procedures, two review authors independently extracted data, assessed risk of bias and assessed the certainty of evidence using GRADE. Outcomes included the number of people with symptomatic urinary tract infections, complications such as urethral trauma/bleeding, comfort and ease of use of catheters, participant satisfaction and preference, quality of life measures and economic outcomes. MAIN RESULTS We included 23 trials (1339 randomised participants), including twelve RCTs and eleven cross-over trials. Most were small (fewer than 60 participants completed), although three trials had more than 100 participants. Length of follow-up ranged from one month to 12 months and there was considerable variation in definitions of UTI. Most of the data from cross-over trials were not presented in a useable form for this review. Risk of bias was unclear in many domains due to insufficient information in the trial reports and several trials were judged to have a high risk of performance bias due to lack of blinding and a high risk of attrition bias. The certainty of evidence was downgraded for risk of bias, and imprecision due to low numbers of participants. Aseptic versus clean technique We are uncertain if there is any difference between aseptic and clean techniques in the risk of symptomatic UTI because the evidence is low-certainty and the 95% confidence interval (CI) is consistent with possible benefit and possible harm (RR 1.20 95% CI 0.54 to 2.66; one study; 36 participants). We identified no data relating to the risk of adverse events comparing aseptic and clean techniques or participant satisfaction or preference. Single-use (sterile) catheter versus multiple-use (clean) We are uncertain if there is any difference between single-use and multiple-use catheters in terms of the risk of symptomatic UTI because the certainty of evidence is low and the 95% CI is consistent with possible benefit and possible harm (RR 0.98, 95% CI 0.55, 1.74; two studies; 97 participants). One study comparing single-use catheters to multiple-use catheters reported zero adverse events in either group; no other adverse event data were reported for this comparison. We identified no data for participant satisfaction or preference. Hydrophilic-coated catheters versus uncoated catheters We are uncertain if there is any difference between hydrophilic and uncoated catheters in terms of the number of people with symptomatic UTI because the certainty of evidence is low and the 95% CI is consistent with possible benefit and possible harm (RR 0.89, 95% CI 0.69 to 1.14; two studies; 98 participants). Uncoated catheters probably slightly reduce the risk of urethral trauma and bleeding compared to hydrophilic-coated catheters (RR 1.37, 95% CI 1.01 to 1.87; moderate-certainty evidence). The evidence is uncertain if hydrophilic-coated catheters compared with uncoated catheters has any effect on participant satisfaction measured on a 0-10 scale (MD 0.7 higher, 95% CI 0.19 to 1.21; very low-certainty evidence; one study; 114 participants). Due to the paucity of data, we could not assess the certainty of evidence relating to participant preference (one cross-over trial of 29 participants reported greater preference for a hydrophilic-coated catheter (19/29) compared to an uncoated catheter (10/29)). AUTHORS' CONCLUSIONS: Despite a total of 23 trials, the paucity of useable data and uncertainty of the evidence means that it remains unclear whether the incidence of UTI or other complications is affected by use of aseptic or clean technique, single (sterile) or multiple-use (clean) catheters, coated or uncoated catheters or different catheter lengths. The current research evidence is uncertain and design and reporting issues are significant. More well-designed trials are needed. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheterisation techniques and strategies, and catheter designs.
Collapse
Affiliation(s)
- Jacqui A Prieto
- Faculty of Health Sciences, University of Southampton, Southampton, UK
| | | | - Fiona Stewart
- c/o Cochrane Incontinence, Population Health Sciences Institute, Newcastle University, Newcastle upon Tyne, UK
| | - Mandy Fader
- Faculty of Health Sciences, University of Southampton, Southampton, UK
| |
Collapse
|
3
|
Prieto J, Murphy CL, Moore KN, Fader M. WITHDRAWN: Intermittent catheterisation for long-term bladder management. Cochrane Database Syst Rev 2017; 8:CD006008. [PMID: 28796279 PMCID: PMC6483323 DOI: 10.1002/14651858.cd006008.pub4] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
BACKGROUND Intermittent catheterisation is a commonly recommended procedure for people with incomplete bladder emptying. There are now several designs of intermittent catheter (e.g. different lengths, 'ready to use' presentation) with different materials (e.g. PVC-free) and coatings (e.g. hydrophilic). The most frequent complication of intermittent catheterisation is urinary tract infection (UTI), but satisfaction, preference and ease of use are also important to users. It is unclear which catheter designs, techniques or strategies affect the incidence of UTI, which are preferable to users and which are most cost effective. OBJECTIVES To compare one type of catheter design versus another, one type of catheter material versus another, aseptic catheterisation technique versus clean technique, single-use (sterile) catheters versus multiple-use (clean) catheters, self-catheterisation versus catheterisation by others and any other strategies designed to reduce UTI and other complications or improve user-reported outcomes (user satisfaction, preference, ease of use) and cost effectiveness in adults and children using intermittent catheterisation for incomplete bladder emptying. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, and handsearching of journals and conference proceedings (searched 30 September 2013), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheter designs, catheterisation techniques or strategies. DATA COLLECTION AND ANALYSIS Two review authors assessed the methodological quality of trials and abstracted data. For dichotomous variables, risk ratios and 95% confidence intervals were derived for each outcome where possible. For continuous variables, mean differences and 95% confidence intervals were calculated for each outcome. Because of trial heterogeneity, it was not always possible to combine data to give an overall estimate of treatment effect. MAIN RESULTS Thirty-one trials met the inclusion criteria, including 13 RCTs and 18 cross-over trials. Most were small (less than 60 participants completed), although five trials had more than 100 participants. There was considerable variation in length of follow-up and definitions of UTI. Participant dropout was a problem for several trials, particularly where there was long-term follow-up to measure incidence of UTI. Fifteen trials were more than 10 years old and focused mainly on comparing different catheterisation techniques (e.g. single versus multiple-use) on clinical outcomes whereas, several more recent trials have focused on comparing different types of catheter designs or materials, especially coatings, and user preference. It was not possible to combine data from some trials owing to variations in the catheters tested and in particular the catheter coatings. Where there were data, confidence intervals around estimates were wide and hence clinically important differences in UTI and other outcomes could neither be identified nor reliably ruled out. No study assessed cost-effectiveness. AUTHORS' CONCLUSIONS Despite a total of 31 trials, there is still no convincing evidence that the incidence of UTI is affected by use of aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, self-catheterisation or catheterisation by others, or by any other strategy. Results from user-reported outcomes varied. The current research evidence is weak and design issues are significant. More well-designed trials are strongly recommended. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheter designs, catheterisation techniques and strategies.
Collapse
Affiliation(s)
- Jacqui Prieto
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| | - Catherine L Murphy
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| | - Katherine N Moore
- University of AlbertaFaculty of Nursing3rd Floor, Clinical Sciences BuildingEdmontonCanadaT6G 2G7
| | - Mandy Fader
- University of SouthamptonFaculty of Health SciencesRoom AA80, South Academic Block (Mailpoint11)Southampton General HospitalSouthamptonUKSO16 6YD
| |
Collapse
|
4
|
Shamout S, Biardeau X, Corcos J, Campeau L. Outcome comparison of different approaches to self-intermittent catheterization in neurogenic patients: a systematic review. Spinal Cord 2017; 55:629-643. [PMID: 28117329 DOI: 10.1038/sc.2016.192] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2016] [Revised: 12/01/2016] [Accepted: 12/11/2016] [Indexed: 02/08/2023]
Abstract
STUDY DESIGN Systematic review (Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA); http://www.prisma-statement.org). OBJECTIVES Different types of catheters and techniques have been described in the past three decades to identify the best self-intermittent catheterization method. Our aim is to review systematically the literature on the most appropriate material and technique to perform self-intermittent catheterization in the adult neurogenic population. METHODS A systematic review search was performed through PubMed/Medline, Embase and Cochrane Central Register of Controlled Trials (CENTRAL) databases to study all types of self-intermittent catheters, and analyzing their impact on urinary tract infections (UTIs), urethral trauma, cost-effectiveness, quality of life and patient's satisfaction. We used the following keywords: 'intermittent catheterization/catheterisation', 'neurogenic', 'urinary catheters for intermittent use' and 'urethral catheterization/catheterisation' published by November 2015. RESULTS After screening 3768 articles, 31 were included in the final synthesis (level of evidence 1b to 2b). The 2188 trial participants were mainly spinal cord injury adults and women with multiple sclerosis. Hydrophilic-coated catheters tended to decrease the incidence of UTI as well as urethral trauma and improve patient's satisfaction when compared with non-hydrophilic-coated catheters. Similarly, prelubricated catheters were associated with better results in terms of patient satisfaction. Sterile technique seemed to decrease the incidence of recurrent UTI; however, these results are counter-balanced by significantly increasing cost compared with clean catheterization. CONCLUSIONS The present review demonstrated advantages of hydrophilic-coated catheters in decreasing risk of UTI and urethral trauma as well as improving patient's satisfaction. Prelubricated catheters has been shown to be superior to conventional polyvinyl chloride catheters. Randomized controlled trials comparing hydrophilic and prelubricated catheters must be conducted to assess possible superiority and cost-effectiveness.
Collapse
Affiliation(s)
- S Shamout
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - X Biardeau
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - J Corcos
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| | - L Campeau
- Division of Urology, Department of Surgery, Jewish General Hospital, Lady Davis Institute for Medical Research, McGill University, Montreal, QC, Canada
| |
Collapse
|
5
|
Ding J, Chen C, Song XC, Zhang L, Deng M, Zhu L. Changes in Prolapse and Urinary Symptoms After Successful Fitting of a Ring Pessary With Support in Women With Advanced Pelvic Organ Prolapse: A Prospective Study. Urology 2015; 87:70-5. [PMID: 26375847 DOI: 10.1016/j.urology.2015.07.025] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2015] [Revised: 07/16/2015] [Accepted: 07/20/2015] [Indexed: 11/28/2022]
Abstract
OBJECTIVE To estimate the percentage of improvement in prolapse and urinary symptoms and adverse effects in women with advanced pelvic organ prolapse (POP) after 3 months of use of a ring pessary with support. MATERIALS AND METHODS In this prospective study, 109 consecutive women with advanced POP were fitted with a ring pessary with support; 73 (73/109, 67.0%) of the women had a successful 3-month pessary fitting trial. Prolapse symptoms, urinary symptoms, and urinary flow parameters were assessed at baseline and at 3 months. Adverse effects were assessed within 3 months. McNemar's test and paired-sample t tests were performed. RESULTS Prolapse and urinary symptoms improved from baseline to 3 months, including bulging (90.4% to 23.3%; P <.001) and pressure (64.4% to 13.7%; P <.001). Voiding difficulty improved in 97.8% of the women (45/46; P <.001), splinting improved in 100% (19/19; P <.001), urge urinary incontinence improved in 76.9% (30/39; P <.001), and stress urinary incontinence improved in 58.1% (18/31; P = .025) after 3 months. After pessary treatment, the differences in maximum flow rate, mean flow rate, void volume, and postvoid residual at baseline and 3 months were statistically significant (P <.05). Vaginal discharge (32/73, 43.8%) was the most common adverse event. Vaginal ulcers developed in 7 (7/73, 9.6%) of the women. CONCLUSION The ring pessary with support was successfully fitted in patients with advanced POP with a high success rate and few complications. The pessary could resolve more than half of the prolapse and urinary symptoms. Therefore, initial conservative treatment with a ring pessary with support in advanced POP is worthwhile.
Collapse
Affiliation(s)
- Jing Ding
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
| | - Chun Chen
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Xiao-Chen Song
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Lei Zhang
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Mou Deng
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China
| | - Lan Zhu
- Departments of Obstetrics and Gynecology, Peking Union Medical College Hospital, Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, China.
| |
Collapse
|
6
|
Prieto JA, Murphy C, Moore KN, Fader MJ. Intermittent catheterisation for long-term bladder management (abridged cochrane review). Neurourol Urodyn 2015; 34:648-53. [DOI: 10.1002/nau.22792] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2015] [Accepted: 04/09/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Jacqui A. Prieto
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| | - Catherine Murphy
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| | | | - Mandy J. Fader
- University of Southampton-Faculty of Health Sciences; South Academic Block, Southampton General Hospital; Southampton United Kingdom
| |
Collapse
|
7
|
Pinder B, Lloyd AJ, Nafees B, Elkin EP, Marley J. Patient preferences and willingness to pay for innovations in intermittent self-catheters. Patient Prefer Adherence 2015; 9:381-8. [PMID: 25834407 PMCID: PMC4358414 DOI: 10.2147/ppa.s73487] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND Intermittent catheterization is the gold standard for bladder management in Europe in people with spinal cord injuries. The aim of the present study was to identify and investigate individuals' preferences regarding intermittent self-catheterization (ISC) devices and furthermore investigate the willingness to pay for attributes in ISC devices in the UK, France, and the Netherlands. METHODS A discrete choice experiment survey was conducted to evaluate the patients' perceived value of catheter features. Attributes were selected based upon a literature review of the most important characteristics of catheters and the survey was developed and validated with input from patients and medical experts. Data were analyzed using the conditional logit model whereby the coefficients obtained from the model provided an estimate of the (log) odds ratios of preference for attributes. Willingness to pay was estimated for all levels of the attributes. RESULTS Two-hundred and eighty-three participants completed the questionnaire and were included in data analysis. Risk of infection had the highest odds ratios as preferred important attribute for all three countries followed by ease of insertion. "Pre-coated catheters" was found to be valued as the most preferred coating technology across all countries. Out of pocket cost was a significant influence on patients' choice. CONCLUSION Users of ISC perceive the value of convenience (size of catheter), ease of insertion, and reduced risk of infection as the most important features attached to an intermittent catheter. These results are applicable both for the "classic" ISC user as well as for another broad group of catheter dependent individuals.
Collapse
Affiliation(s)
| | | | - Beenish Nafees
- ICON plc, Oxford, UK
- Correspondence: Beenish Nafees, ICON plc, Seacourt Tower, West Way, Oxford OX2 0JJ, UK, Tel +44 7957 634 170, Email
| | | | - Jerome Marley
- School of Nursing, University of Ulster, Newtownabbey, UK
| |
Collapse
|
8
|
Abstract
BACKGROUND Intermittent catheterisation is a commonly recommended procedure for people with incomplete bladder emptying. There are now several designs of intermittent catheter (e.g. different lengths, 'ready to use' presentation) with different materials (e.g. PVC-free) and coatings (e.g. hydrophilic). The most frequent complication of intermittent catheterisation is urinary tract infection (UTI), but satisfaction, preference and ease of use are also important to users. It is unclear which catheter designs, techniques or strategies affect the incidence of UTI, which are preferable to users and which are most cost effective. OBJECTIVES To compare one type of catheter design versus another, one type of catheter material versus another, aseptic catheterisation technique versus clean technique, single-use (sterile) catheters versus multiple-use (clean) catheters, self-catheterisation versus catheterisation by others and any other strategies designed to reduce UTI and other complications or improve user-reported outcomes (user satisfaction, preference, ease of use) and cost effectiveness in adults and children using intermittent catheterisation for incomplete bladder emptying. SEARCH METHODS We searched the Cochrane Incontinence Group Specialised Register, which contains trials identified from the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, MEDLINE in process, and handsearching of journals and conference proceedings (searched 30 September 2013), the reference lists of relevant articles and conference proceedings, and we attempted to contact other investigators for unpublished data or for clarification. SELECTION CRITERIA Randomised controlled trials (RCTs) or randomised cross-over trials comparing at least two different catheter designs, catheterisation techniques or strategies. DATA COLLECTION AND ANALYSIS Two review authors assessed the methodological quality of trials and abstracted data. For dichotomous variables, risk ratios and 95% confidence intervals were derived for each outcome where possible. For continuous variables, mean differences and 95% confidence intervals were calculated for each outcome. Because of trial heterogeneity, it was not always possible to combine data to give an overall estimate of treatment effect. MAIN RESULTS Thirty-one trials met the inclusion criteria, including 13 RCTs and 18 cross-over trials. Most were small (less than 60 participants completed), although five trials had more than 100 participants. There was considerable variation in length of follow-up and definitions of UTI. Participant dropout was a problem for several trials, particularly where there was long-term follow-up to measure incidence of UTI. Fifteen trials were more than 10 years old and focused mainly on comparing different catheterisation techniques (e.g. single versus multiple-use) on clinical outcomes whereas, several more recent trials have focused on comparing different types of catheter designs or materials, especially coatings, and user preference. It was not possible to combine data from some trials owing to variations in the catheters tested and in particular the catheter coatings. Where there were data, confidence intervals around estimates were wide and hence clinically important differences in UTI and other outcomes could neither be identified nor reliably ruled out. No study assessed cost-effectiveness. AUTHORS' CONCLUSIONS Despite a total of 31 trials, there is still no convincing evidence that the incidence of UTI is affected by use of aseptic or clean technique, coated or uncoated catheters, single (sterile) or multiple-use (clean) catheters, self-catheterisation or catheterisation by others, or by any other strategy. Results from user-reported outcomes varied. The current research evidence is weak and design issues are significant. More well-designed trials are strongly recommended. Such trials should include analysis of cost-effectiveness because there are likely to be substantial differences associated with the use of different catheter designs, catheterisation techniques and strategies.
Collapse
Affiliation(s)
- Jacqui Prieto
- Faculty of Health Sciences, University of Southampton, Room AA80, South Academic Block (Mailpoint11), Southampton General Hospital, Southampton, UK, SO16 6YD
| | | | | | | |
Collapse
|
9
|
Residual urine volumes after intermittent catheterization in men with spinal cord injury. Spinal Cord 2013; 51:776-9. [PMID: 23939190 DOI: 10.1038/sc.2013.81] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2013] [Revised: 06/25/2013] [Accepted: 06/27/2013] [Indexed: 11/08/2022]
Abstract
STUDY DESIGN Prospective cross-sectional study. OBJECTIVES To investigate residual urine volumes after intermittent catheterization (IC) in men with spinal cord injury (SCI) and the effect of residual urine on the rate of symptomatic urinary tract infections (UTIs). SETTING Single SCI rehabilitation center in Switzerland. METHODS Sixty men experienced in IC (≥ 6 months) emptied their bladder twice by IC. Immediately after catheterization, residual urine was determined by ultrasonography. Personal characteristics and bladder diary details (annual UTI rate, catheter type) were also collected. RESULTS The median residual urine volume was 7.0 ml (lower quartile (LQ): 0.0, upper quartile (UQ): 20.3 ml). No residual urine was observed after 42% (n=50) of all catheterizations (n=120). Unsatisfactory residual volumes (that is, >50 ml) were observed after 9% (n=11) of all catheterizations. There was no significant (P=0.95) difference between the median residual urine volume of men with recurrent (>2 UTIs per year) UTIs (2.5 ml, LQ: 0.0, UQ: 29.3 ml) and the volume of those with sporadic (≤ 2 UTIs per year) UTIs (6.0 ml, LQ: 0.0, UQ: 20.0 ml). CONCLUSIONS Bladder evacuation by IC is an efficient method, resulting in zero or small residual urine volumes. The small residual urine volumes generally observed after IC do not predispose for UTIs.
Collapse
|
10
|
Chartier-Kastler E, Amarenco G, Lindbo L, Soljanik I, Andersen HL, Bagi P, Gjødsbøl K, Domurath B. A prospective, randomized, crossover, multicenter study comparing quality of life using compact versus standard catheters for intermittent self-catheterization. J Urol 2013; 190:942-7. [PMID: 23587630 DOI: 10.1016/j.juro.2013.04.026] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2013] [Accepted: 04/04/2013] [Indexed: 11/29/2022]
Abstract
PURPOSE Intermittent catheterization is the recommended standard treatment for neurogenic bladder dysfunction. However, standard intermittent catheters can be unwieldy, difficult to use and carry discreetly. This can influence patient ability to perform catheterization efficiently, discreetly and privately, therefore, affecting patient quality of life. We evaluated whether the discreet design of the compact catheter would improve quality of life in intermittent catheterization users compared with standard catheters. MATERIALS AND METHODS We performed a nonblinded, randomized, multicenter, 2-way crossover study with 2 treatment periods of 6 weeks ± 3 days. A total of 125 patients with neurogenic bladder dysfunction were included in the study from 17 study sites, including 7 in France, 3 each in Germany, Denmark and Sweden, and 1 in Norway. Quality of life was evaluated by the intermittent self-catheterization questionnaire. The difference in questionnaire scores between the compact catheter and standard hydrophilic coated catheters was analyzed using a mixed linear normal model. RESULTS The intermittent catheterization questionnaire score increased significantly due to compact catheter use. We noted an estimated mean difference of 17.0 between the compact and standard intermittent catheters (p <0.001), corresponding to a 28% increase. The primary study results were further supported by the positive results of the secondary objective of preference, that is 63% of patients preferred the compact catheter. CONCLUSIONS The discreet design of the compact catheter significantly improved patient quality of life related to intermittent self-catheterization.
Collapse
|
11
|
Boucher A, Cloutier J, Lebel S, Hamel M, Lamontagne P, Bolduc S. Hydrophilic-coated catheter appreciation study in a pediatric population. Can Urol Assoc J 2011; 4:e150-4. [PMID: 21749816 DOI: 10.5489/cuaj.09138] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The objective of the paper was to compare the satisfaction of hydrophilic-coated catheters (HC) (SpeediCath, Coloplast Canada, Mississauga, ON) versus uncoated catheters in a pediatric neurogenic bladder population, in order to identify a target group for HC. The main hypothesis was that our patients, with regard to their limitations, might have difficulties using the HC. MATERIAL AND METHODS A comparative prospective study was initiated in one pediatric rehabilitation centre. Out of the 39 patients who tried the HC during a routine clinic visit, 31 patients/parents accepted to participate in a 1-week trial and to answer a satisfaction questionnaire. Their medical records were reviewed for age, neurological disease, intellectual deficit, impaired dexterity and method of catheterization (Mitrofanoff/urethra). RESULTS Thirty of the 31 patients answered the satisfaction questionnaire. The median age for the 30 patients was 13.5 years (range 6-20 years). Of these patients, 19 were females (63%), 26 performed self-catheterization (87%), and 6 had Mitrofanoff (20%). Ten children (33%) would be ready to proceed with HC and all 10 children would receive catheterization by the urethra. Of these, 9 were females (90%), 8 used compact-HC (80%) and all were self-sufficient. Patients using compact-HC would continue with this catheter. In the patient comments, males catheterizing per-urethra and patients using a continent stoma requiring long catheters had problems with the excess of lubricant. CONCLUSION Most children preferred their usual uncoated catheter and would not change for HC. Female patients catheterizing per-urethra with a compact-HC seem to benefit most from this catheter.
Collapse
Affiliation(s)
- Andréanne Boucher
- Division of Urology, Centre Hospitalier Universitaire de Québec, Université Laval, Québec, QC
| | | | | | | | | | | |
Collapse
|
12
|
Park YH, Ku JH, Oh SJ. Accuracy of post-void residual urine volume measurement using a portable ultrasound bladder scanner with real-time pre-scan imaging. Neurourol Urodyn 2011; 30:335-8. [PMID: 20658544 DOI: 10.1002/nau.20977] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
AIMS To evaluate whether the bladder scanner with real-time pre-scan imaging (RPI) is superior to the conventional bladder scanner in measuring post-void residual urine (PVR) volume. METHODS Sixty-seven patients with voiding dysfunction were subjected to PVR volume measurements. The PVR volume was measured three times by two experienced examiners using bladder scanners with (BioCon-500, Mcube Technology, Seoul, Korea) or without (BVI-3000 BladderScan, Verathon, WA) RPI. Immediately after the procedure, urethral catheterization was performed to obtain true volume. The accuracy and variability of measurements were compared between the two devices and correlation coefficients were obtained. RESULTS The Pearson correlation coefficients between the PVR volume measured by each device and the true volume were 0.932 for the bladder scanner without RPI and 0.950 for the bladder scanner with RPI. The bladder scanner without RPI tended to overestimate the true volume in moderate volume ranges (>100 ml) by a mean percentage of differences of volume (PDV) of 16.3%, while the bladder scanner with RPI underestimated the true volume in the whole volume range by a mean PDV of -14.1% (P<0.001). Repeated measures ANOVA showed no significant interobserver variability (P=0.977 for the bladder scanner without RPI and P=0.853 for the bladder scanner with RPI) or intraobserver variability (P=0.660 for the bladder scanner without RPI and P=0.271 for the bladder scanner with RPI). CONCLUSIONS Our results showed that exact pointing to the bladder prior to actual measurement of bladder volume with RPI seems to reduce the variability of the measured values.
Collapse
Affiliation(s)
- Yong Hyun Park
- Department of Urology, Seoul National University College of Medicine, Seoul, Korea
| | | | | |
Collapse
|
13
|
Clinical evaluation of a newly developed catheter (SpeediCath Compact Male) in men with spinal cord injury: residual urine and user evaluation. Spinal Cord 2011; 49:817-21. [DOI: 10.1038/sc.2011.14] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
14
|
Chartier-Kastler E, Lauge I, Ruffion A, Goossens D, Charvier K, Biering-Sørensen F. Safety of a new compact catheter for men with neurogenic bladder dysfunction: a randomised, crossover and open-labelled study. Spinal Cord 2011; 49:844-50. [DOI: 10.1038/sc.2011.5] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
15
|
Bagi P, Hannibalsen J, Permild R, Stilling S, Looms DK. Safety of a New Compact Male Intermittent Catheter: Randomized, Cross-Over, Single-Blind Study in Healthy Male Volunteers. Urol Int 2011; 86:179-84. [DOI: 10.1159/000321900] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2010] [Accepted: 10/03/2010] [Indexed: 12/13/2022]
|
16
|
Chartier-Kastler E, Denys P. Intermittent catheterization with hydrophilic catheters as a treatment of chronic neurogenic urinary retention. Neurourol Urodyn 2010; 30:21-31. [PMID: 20928913 DOI: 10.1002/nau.20929] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2009] [Accepted: 03/15/2010] [Indexed: 11/07/2022]
Abstract
AIMS Neurogenic bladder can be effectively managed with intermittent catheterization (IC) to improve or restore continence, but there is no consensus on which type of catheter is preferred. Hydrophilic catheters were developed to reduce urethral friction, thereby minimizing trauma and sticking, and making them more acceptable to the patient, and easier and safer to use. The objective of this article was to review the literature on the benefits of hydrophilic catheters in patients with neurogenic bladder. METHODS A large body of experimental and observational evidence, including randomized controlled trials, was identified using PubMed. RESULTS Compared with plastic catheters that have been manually lubricated with gel, hydrophilic catheters reduce urinary tract infection and microhematuria. Hydrophilic catheters are also associated with high levels of patient satisfaction because they are comfortable to use. CONCLUSIONS There is a wealth of evidence, including randomized controlled trials, to support the benefits of hydrophilic catheters in terms of safety and quality of life, especially in men with spinal cord injury. More data are required for spina bifida, multiple sclerosis, and in women. Further research is warranted, especially large-scale and long-term robust comparisons of different types of catheter, and in well-defined and stratified populations.
Collapse
|