1
|
Consagra W, Ning L, Rathi Y. Neural orientation distribution fields for estimation and uncertainty quantification in diffusion MRI. Med Image Anal 2024; 93:103105. [PMID: 38377728 DOI: 10.1016/j.media.2024.103105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 12/13/2023] [Accepted: 02/05/2024] [Indexed: 02/22/2024]
Abstract
Inferring brain connectivity and structure in-vivo requires accurate estimation of the orientation distribution function (ODF), which encodes key local tissue properties. However, estimating the ODF from diffusion MRI (dMRI) signals is a challenging inverse problem due to obstacles such as significant noise, high-dimensional parameter spaces, and sparse angular measurements. In this paper, we address these challenges by proposing a novel deep-learning based methodology for continuous estimation and uncertainty quantification of the spatially varying ODF field. We use a neural field (NF) to parameterize a random series representation of the latent ODFs, implicitly modeling the often ignored but valuable spatial correlation structures in the data, and thereby improving efficiency in sparse and noisy regimes. An analytic approximation to the posterior predictive distribution is derived which can be used to quantify the uncertainty in the ODF estimate at any spatial location, avoiding the need for expensive resampling-based approaches that are typically employed for this purpose. We present empirical evaluations on both synthetic and real in-vivo diffusion data, demonstrating the advantages of our method over existing approaches.
Collapse
Affiliation(s)
- William Consagra
- Psychiatry Neuroimaging Laboratory, Brigham and Women's Hospital, Harvard Medical School, 399 Revolution Drive, Boston, 02215, MA, United States.
| | - Lipeng Ning
- Psychiatry Neuroimaging Laboratory, Brigham and Women's Hospital, Harvard Medical School, 399 Revolution Drive, Boston, 02215, MA, United States
| | - Yogesh Rathi
- Psychiatry Neuroimaging Laboratory, Brigham and Women's Hospital, Harvard Medical School, 399 Revolution Drive, Boston, 02215, MA, United States
| |
Collapse
|
2
|
Ren Y, Gao Y, Qiu B, Nan X, Han J. Effects of radiofrequency channel numbers on B 1+ mapping using the Bloch-Siegert shift method. Neuroimage 2023; 279:120308. [PMID: 37544415 DOI: 10.1016/j.neuroimage.2023.120308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 07/14/2023] [Accepted: 08/03/2023] [Indexed: 08/08/2023] Open
Abstract
PURPOSE This paper aims to investigate the impact of the channel numbers on the performance of B1+ mapping, by using the Bloch-Siegert shift (BSS) method. B1+ mapping plays a crucial role in various brain imaging protocols. THEORY AND METHODS We simulated the radiofrequency field of the human head model in six groups of multi-channel receive coil with a range of different channel numbers. MR signals were synthesized according to the standard BSS sequence, with quantified Gaussian added. Next, we combined the signals of each channel to reconstruct the B1+ map by weighted averaging and maximum likelihood estimation strategies and evaluate the bias by relative standard deviation of each coil. RESULTS The simulation results revealed that the accuracy of B1+ maps improved with the increasing of channel numbers, meanwhile the per channel efficiency of B1+maps accuracy gradually decrease. Both trends slowed down when the channel numbers reached 12 or above. CONCLUSION Our finding suggests that increasing the channel numbers can improve the accuracy of B1+map. However, a diminishing efficiency of per channel accuracy improvement was overserved, indicating that the relationship between quality of B1+ map and the channel numbers is nonlinear. Based on these findings, our study provides a reference for determining channel numbers to achieve a balance of coil selection and manufacturing cost. It also provides a theoretical basis for evaluating other B1+ mapping techniques.
Collapse
Affiliation(s)
- Yinhao Ren
- School of Biomedical Engineering, Anhui Medical University, Hefei, China
| | - Yunyu Gao
- School of Biomedical Engineering, Southern Medical University, Guangzhou, China
| | - Bensheng Qiu
- Center for Biomedical Imaging, University of Science and Technology of China, Hefei, China
| | - Xiang Nan
- Department of Anatomy, Anhui Medical University, Hefei, China.
| | - Jijun Han
- School of Biomedical Engineering, Anhui Medical University, Hefei, China.
| |
Collapse
|
3
|
Feizollah S, Tardif CL. High-resolution diffusion-weighted imaging at 7 Tesla: single-shot readout trajectories and their impact on signal-to-noise ratio, spatial resolution and accuracy. Neuroimage 2023; 274:120159. [PMID: 37150332 DOI: 10.1016/j.neuroimage.2023.120159] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2023] [Revised: 03/31/2023] [Accepted: 05/04/2023] [Indexed: 05/09/2023] Open
Abstract
Diffusion MRI (dMRI) is a valuable imaging technique to study the connectivity and microstructure of the brain in vivo. However, the resolution of dMRI is limited by the low signal-to-noise ratio (SNR) of this technique. Various multi-shot acquisition strategies have been developed to achieve sub-millimeter resolution, but they require long scan times which can be restricting for patient scans. Alternatively, the SNR of single-shot acquisitions can be increased by using a spiral readout trajectory to minimize the sequence echo time. Imaging at ultra-high fields (UHF) could further increase the SNR of single-shot dMRI; however, the shorter T2* of brain tissue and the greater field non-uniformities at UHFs will degrade image quality, causing image blurring, distortions, and signal loss. In this study, we investigated the trade-off between the SNR and resolution of different k-space trajectories, including echo planar imaging (EPI), partial Fourier EPI, and spiral trajectories, over a range of dMRI resolutions at 7T. The effective resolution, spatial specificity and sharpening effect were measured from the point spread function (PSF) of the simulated diffusion sequences for a nominal resolution range of 0.6-1.8 mm. In-vivo partial brain scans at a nominal resolution of 1.5 mm isotropic were acquired using the three readout trajectories to validate the simulation results. Field probes were used to measure dynamic magnetic fields offline up to the 3rd order of spherical harmonics. Image reconstruction was performed using static ΔB0 field maps and the measured trajectories to correct image distortions and artifacts, leaving T2* effects as the primary source of blurring. The effective resolution was examined in fractional anisotropy (FA) maps calculated from a multi-shell dataset with b-values of 300, 1000, and 2000 s/mm2 in 5, 16, and 48 directions, respectively. In-vivo scans at nominal resolutions of 1, 1.2, and 1.5 mm were acquired and the SNR of the different trajectories calculated using the multiple replica method to investigate the SNR. Finally, in-vivo whole brain scans with an effective resolution of 1.5 mm isotropic were acquired to explore the SNR and efficiency of different trajectories at a matching effective resolution. FA and intra-cellular volume fraction (ICVF) maps calculated using neurite orientation dispersion and density imaging (NODDI) were used for the comparison. The simulations and in vivo imaging results showed that for matching nominal resolutions, EPI trajectories had the highest specificity and effective resolution with maximum image sharpening effect. However, spirals have a significantly higher SNR, in particular at higher resolutions and even when the effective image resolutions are matched. Overall, this work shows that the higher SNR of single-shot spiral trajectories at 7T allows us to achieve higher effective resolutions compared to EPI and PF-EPI to map the microstructure and connectivity of small brain structures.
Collapse
Affiliation(s)
- Sajjad Feizollah
- Department of Neurology and Neurosurgery, Faculty of Medicine and Health Sciences, McGill University, 3801 Rue University, Montreal, QC, Canada; McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, 3801 Rue University, Montreal, QC, Canada.
| | - Christine L Tardif
- Department of Neurology and Neurosurgery, Faculty of Medicine and Health Sciences, McGill University, 3801 Rue University, Montreal, QC, Canada; McConnell Brain Imaging Centre, Montreal Neurological Institute, McGill University, 3801 Rue University, Montreal, QC, Canada; Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Duff Medical Building, 3775 Rue University, Suite 316, Montreal, QC, Canada.
| |
Collapse
|
4
|
Malte Oeschger J, Tabelow K, Mohammadi S. Axisymmetric diffusion kurtosis imaging with Rician bias correction: A simulation study. Magn Reson Med 2023; 89:787-799. [PMID: 36198046 DOI: 10.1002/mrm.29474] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Revised: 09/01/2022] [Accepted: 09/04/2022] [Indexed: 12/13/2022]
Abstract
PURPOSE To compare the estimation accuracy of axisymmetric diffusion kurtosis imaging (DKI) and standard DKI in combination with Rician bias correction (RBC). METHODS Axisymmetric DKI is more robust against noise-induced variation in the measured signal than standard DKI because of its reduced parameter space. However, its susceptibility to Rician noise bias at low signal-to-noise ratios (SNR) is unknown. Here, we investigate two main questions: first, does RBC improve estimation accuracy of axisymmetric DKI?; second, is estimation accuracy of axisymmetric DKI increased compared to standard DKI? Estimation accuracy was investigated on the five axisymmetric DKI tensor metrics (AxTM): the parallel and perpendicular diffusivity and kurtosis and mean of the kurtosis tensor, using a noise simulation study based on synthetic data of tissues with varying fiber alignment and in-vivo data focusing on white matter. RESULTS RBC mainly increased accuracy for the parallel AxTM in tissues with highly to moderately aligned fibers. For the perpendicular AxTM, axisymmetric DKI without RBC performed slightly better than with RBC. However, the combination of axisymmetric DKI with RBC was the overall best performing algorithm across all five AxTM in white matter and axisymmetric DKI itself substantially improved accuracy in axisymmetric tissues with low fiber alignment. CONCLUSION Combining axisymmetric DKI with RBC facilitates accurate DKI parameter estimation at unprecedented low SNRs ( ≈ 15 $$ \approx 15 $$ ) in white matter, possibly making it a valuable tool for neuroscience and clinical research studies where scan time is a limited resource. The tools used here are available in the open-source ACID toolbox for SPM.
Collapse
Affiliation(s)
- Jan Malte Oeschger
- Institute of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Karsten Tabelow
- Weierstrass Institute for Applied Analysis and Stochastics, Berlin, Germany
| | - Siawoosh Mohammadi
- Institute of Systems Neuroscience, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.,Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| |
Collapse
|
5
|
Cole JH. Multimodality neuroimaging brain-age in UK biobank: relationship to biomedical, lifestyle, and cognitive factors. Neurobiol Aging 2020; 92:34-42. [PMID: 32380363 PMCID: PMC7280786 DOI: 10.1016/j.neurobiolaging.2020.03.014] [Citation(s) in RCA: 167] [Impact Index Per Article: 41.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/05/2020] [Accepted: 03/24/2020] [Indexed: 01/01/2023]
Abstract
The brain-age paradigm is proving increasingly useful for exploring aging-related disease and can predict important future health outcomes. Most brain-age research uses structural neuroimaging to index brain volume. However, aging affects multiple aspects of brain structure and function, which can be examined using multimodality neuroimaging. Using UK Biobank, brain-age was modeled in n = 2205 healthy people with T1-weighted MRI, T2-FLAIR, T2∗, diffusion-MRI, task fMRI, and resting-state fMRI. In a held-out healthy validation set (n = 520), chronological age was accurately predicted (r = 0.78, mean absolute error = 3.55 years) using LASSO regression, higher than using any modality separately. Thirty-four neuroimaging phenotypes were deemed informative by the regression (after bootstrapping); predominantly gray-matter volume and white-matter microstructure measures. When applied to new individuals from UK Biobank (n = 14,701), significant associations with multimodality brain-predicted age difference (brain-PAD) were found for stroke history, diabetes diagnosis, smoking, alcohol intake and some, but not all, cognitive measures (corrected p < 0.05). Multimodality neuroimaging can improve brain-age prediction, and derived brain-PAD values are sensitive to biomedical and lifestyle factors that negatively impact brain and cognitive health. Brain-age was predicted from 6 different neuroimaging modalities. Combined multi-modality brain-age was more accurate than any single modality. Thirty-four neuroimaging measures were informative for brain-age prediction. Informative measures generally reflect brain volume and white-matter microstructure. Brain-age was associated with stroke, diabetes, smoking, alcohol and cognition.
Collapse
Affiliation(s)
- James H Cole
- Department of Neuroimaging, Institute of Psychiatry, Psychology & Neuroscience, King's College London, London, UK; Centre for Medical Image Computing, Department of Computer Science, University College London, London, UK; Dementia Research Centre, Institute of Neurology, University College London, London, UK.
| |
Collapse
|
6
|
Peña-Nogales Ó, Hernando D, Aja-Fernández S, de Luis-Garcia R. Determination of optimized set of b-values for Apparent Diffusion Coefficient mapping in liver Diffusion-Weighted MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 310:106634. [PMID: 31710951 DOI: 10.1016/j.jmr.2019.106634] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/08/2019] [Revised: 10/21/2019] [Accepted: 10/25/2019] [Indexed: 06/10/2023]
Abstract
In this manuscript we derive the Cramér-Rao Lower Bound (CRLB) of the monoexponential diffusion-weighted signal model under a realistic noise assumption, and propose a formulation to obtain optimized sets of b-values that maximize the noise performance of the Apparent Diffusion Coefficient (ADC) maps given a target ADC and a signal-to-noise ratio. Therefore, for various sets of parameters (S0 and ADC), signal-to-noise ratios (SNR) and noise distribution, we computed optimized sets of b-values using CRLB-based analysis in two different ways: (i) through a greedy algorithm where b-values from a pool of candidates were added iteratively to the set, and (ii) through a two b-value search algorithm were all two b-value combinations of the pool of candidates were tested. Further, optimized sets of b-values were computed from synthetic data, phantoms, and in-vivo liver diffusion-weighted imaging (DWI) experiments to validate the CRLB-based analysis. The optimized sets of b-values obtained through the proposed CRLB-based analysis showed good agreement with the optimized sets obtained experimentally from synthetic, phantoms, and in-vivo liver data. The variance of the ADC maps decreased when employing the optimized set of b-values compared to various sets of b-values proposed in the literature for in-vivo liver DWI, although differences of notable magnitude between noise models and optimization strategies were not found. In addition, the higher b-values decreased for lower SNR under the Rician noise distribution. Optimization of the set b-values is critical to maximize the noise performance (i.e., maximize the precision and minimize the variance) of the estimated ADC maps in diffusion-weighted MRI. Hence, the proposed approach may help to optimize and standardize liver diffusion-weighted MRI acquisitions by computing optimized set of b-values for a given set of parameters.
Collapse
Affiliation(s)
- Óscar Peña-Nogales
- Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain. http://www.lpi.tel.uva.es
| | - Diego Hernando
- Departments of Radiology, Medical Physics, and Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States
| | | | | |
Collapse
|
7
|
Tabelow K, Balteau E, Ashburner J, Callaghan MF, Draganski B, Helms G, Kherif F, Leutritz T, Lutti A, Phillips C, Reimer E, Ruthotto L, Seif M, Weiskopf N, Ziegler G, Mohammadi S. hMRI - A toolbox for quantitative MRI in neuroscience and clinical research. Neuroimage 2019; 194:191-210. [PMID: 30677501 PMCID: PMC6547054 DOI: 10.1016/j.neuroimage.2019.01.029] [Citation(s) in RCA: 129] [Impact Index Per Article: 25.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 12/21/2018] [Accepted: 01/10/2019] [Indexed: 12/20/2022] Open
Abstract
Neuroscience and clinical researchers are increasingly interested in quantitative magnetic resonance imaging (qMRI) due to its sensitivity to micro-structural properties of brain tissue such as axon, myelin, iron and water concentration. We introduce the hMRI-toolbox, an open-source, easy-to-use tool available on GitHub, for qMRI data handling and processing, presented together with a tutorial and example dataset. This toolbox allows the estimation of high-quality multi-parameter qMRI maps (longitudinal and effective transverse relaxation rates R1 and R2⋆, proton density PD and magnetisation transfer MT saturation) that can be used for quantitative parameter analysis and accurate delineation of subcortical brain structures. The qMRI maps generated by the toolbox are key input parameters for biophysical models designed to estimate tissue microstructure properties such as the MR g-ratio and to derive standard and novel MRI biomarkers. Thus, the current version of the toolbox is a first step towards in vivo histology using MRI (hMRI) and is being extended further in this direction. Embedded in the Statistical Parametric Mapping (SPM) framework, it benefits from the extensive range of established SPM tools for high-accuracy spatial registration and statistical inferences and can be readily combined with existing SPM toolboxes for estimating diffusion MRI parameter maps. From a user's perspective, the hMRI-toolbox is an efficient, robust and simple framework for investigating qMRI data in neuroscience and clinical research.
Collapse
Affiliation(s)
| | | | | | | | - Bogdan Draganski
- Laboratory for Research in Neuroimaging, Department of Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Switzerland; Department of Neurology, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Gunther Helms
- Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
| | - Ferath Kherif
- Laboratory for Research in Neuroimaging, Department of Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Switzerland
| | - Tobias Leutritz
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Antoine Lutti
- Laboratory for Research in Neuroimaging, Department of Clinical Neuroscience, Lausanne University Hospital and University of Lausanne, Switzerland
| | | | - Enrico Reimer
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | | | | | - Nikolaus Weiskopf
- Department of Neurophysics, Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany
| | - Gabriel Ziegler
- Institute for Cognitive Neurology and Dementia Research, University of Magdeburg, Germany
| | | |
Collapse
|