1
|
Biddulph B, Morris JG, Lewis M, Hunter K, Sunderland C. Reliability of Near-Infrared Spectroscopy with and without Compression Tights during Exercise and Recovery Activities. Sports (Basel) 2023; 11:sports11020023. [PMID: 36828308 PMCID: PMC9965473 DOI: 10.3390/sports11020023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 01/06/2023] [Accepted: 01/13/2023] [Indexed: 01/20/2023] Open
Abstract
Near-infrared spectroscopy (NIRS) is widely used in sports science research, despite the limited reliability of available data. The aim of the present study was to assess the reliability of NIRS with and without compression tights. Thirteen healthy active males, (age 21.5 ± 2.7 years, body mass 82.1 ± 11.2 kg, BMI 24.6 ± 3.2 kg·m-2) completed four trials (two control trials and two trials using compression tights) over a 28-day period. During each trial, participants completed 20 min each of laying supine, sitting, walking (4 km·h-1), jogging, and sitting following the jogging. An NIRS device was attached to the muscle belly of the vastus lateralis and gastrocnemius and recorded tissue saturation index (TSI), muscle oxygenation, and muscle deoxygenation. Systematic bias and 95% limits of agreement (LOA) and coefficient of variation (CV) were used to report reliability measures for each activity type. For TSI, systematic bias (LOA) at the gastrocnemius during the control and tights trial ranged from -0.4 to 1.7% (4.4 to 10.3%) and -1.9 to 3.5% (8.1 to 12.0%), respectively. For the vastus lateralis, the systematic bias (LOA) for the control trial ranged from -2.4 to 1.0% (5.1 to 6.9%) and for the tights trial was -0.8 to 0.6% (7.0 to 9.5%). For TSI, the CV during the control trial ranged from 1.7 to 4.0% for the gastrocnemius and 1.9 to 2.6% for the vastus lateralis. During the tights trials, the CV ranged from 3.0 to 4.5% for the gastrocnemius and 2.6 to 3.5% for the vastus lateralis. The CV for muscle oxygenation during the control and tights trials for the gastrocnemius was 2.7 to 6.2% and 1.0 to 8.8% and for the vastus lateralis was 0.6 to 4.0% and 4.0 to 4.5%, respectively. The relative reliability was poorer in the tights trials, but if the aim was to detect a 5% difference in TSI, NIRS would be sufficiently reliable. However, the reliability of muscle oxygenation and deoxygenation varies considerably with activity type, and this should be considered when determining whether to employ NIRS in research studies.
Collapse
Affiliation(s)
- Brett Biddulph
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - John G Morris
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | | | - Kirsty Hunter
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
| | - Caroline Sunderland
- Sport, Health and Performance Enhancement (SHAPE) Research Centre, Department of Sport Science, Nottingham Trent University, Nottingham NG11 8NS, UK
- Correspondence: ; Tel.: +44-(0)1158486379
| |
Collapse
|
2
|
Effects of 24 h Compression Interventions with Different Garments on Recovery Markers during Running. Life (Basel) 2021; 11:life11090905. [PMID: 34575054 PMCID: PMC8471437 DOI: 10.3390/life11090905] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2021] [Revised: 08/20/2021] [Accepted: 08/27/2021] [Indexed: 11/24/2022] Open
Abstract
Compression and temperature manipulation are discussed as strategies to improve performance markers and recovery in sports. Here, we investigate the effects of compression stockings made with fabric, either combined or not with heating and cooling substances, on variables related to running performance and recovery. Ten trained runners (mean ± standard deviation age 45 ± 9 years old, body mass 69 ± 7 kg, height 166 ± 4 cm) with no experience of using compression garments performed an intense running session of 10 km, then wore a stocking for 24 h (randomized; without compression, compression, compression with camphor, and compression with menthol), and were evaluated on the following day, after running 5 km. The different types of compression stockings used 24 h before exercise did not affect running kinematics (p > 0.14), skin temperature (p > 0.05), heart rate (p > 0.12; mean value of maximal heart rate 156 bpm), comfort perception (p = 0.13; mean value of 7/10 points), or perception of recovery (p = 0.13; mean value of 7/10 points). In general, there were no effects of 24 h pre-exercise lower leg compression, including those treated with menthol and camphor applications on running kinematics, skin temperature, heart rate, or recovery perception in athletes undertaking consecutive running exercises.
Collapse
|
3
|
Predicting Compression Pressure of Knitted Fabric Using a Modified Laplace's Law. MATERIALS 2021; 14:ma14164461. [PMID: 34442988 PMCID: PMC8401858 DOI: 10.3390/ma14164461] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 08/03/2021] [Accepted: 08/04/2021] [Indexed: 11/29/2022]
Abstract
The aim of this study is to develop a mathematical model for the prediction of compression pressure based on fabric parameters, such as engineering stress, engineering strain and engineering modulus of elasticity. Four knitted compression fabrics with different fibrous compositions and knit structures were used. Rectangular-cut strips were employed for the force–elongation characterization of the fabrics. The experimental pressure values between the fabric and rigid cylinder were assessed using a Picopress pressure measuring device. The mechanical and physical parameters of the fabric that influence the interface pressure, such as strain, elasticity modulus/stress and thickness, were determined and integrated into Laplace’s law. A good correlation was observed between the experimental and calculated pressure values for all combinations of fabrics, mounted with variable tension on the cylinder. Over the considered range of pressures, the difference between the two datasets was generally less than 0.5 mmHg. The effect of washing after five, ten and fifteen washing cycles on the fabric–cylinder interface pressure was found to be significant.
Collapse
|
4
|
O'Riordan SF, McGregor R, Halson SL, Bishop DJ, Broatch JR. Sports compression garments improve resting markers of venous return and muscle blood flow in male basketball players. JOURNAL OF SPORT AND HEALTH SCIENCE 2021:S2095-2546(21)00092-2. [PMID: 34314879 PMCID: PMC10362518 DOI: 10.1016/j.jshs.2021.07.010] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/10/2021] [Accepted: 06/21/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND The benefits associated with sports compression garments are thought to be closely related to enhanced blood flow. However, findings are equivocal, possibly due to heterogeneity in the techniques used for measuring blood flow, the garment types used, and the pressures applied. This study combined Doppler ultrasound and near-infrared spectroscopy technologies to provide the first comprehensive assessment of the effects of 3 sports compression garment types on markers of venous return and muscle blood flow at rest. METHODS Resting lower-limb blood flow measures (markers of venous return, muscle blood flow, and muscle oxygenation) of 22 elite, junior, male basketball players (age = 17.2 ± 0.9 years, mean ± SD) were assessed in 4 separate conditions: no compression (CON), compression tights (TIGHTS), compression shorts (SHORTS), and compression socks (SOCKS). Markers of venous return (cross-sectional area, time-averaged mean and peak blood flow velocity, and venous blood flow) were measured via Doppler ultrasound at the popliteal and common femoral veins. Muscle blood flow and muscle oxygenation were measured in the gastrocnemius medialis and vastus lateralis using near-infrared spectroscopy. RESULTS Popliteal markers of venous return were higher in TIGHTS compared to CON (p < 0.01) and SHORTS (p < 0.01), with SOCKS values higher compared with CON (p < 0.05). Common femoral vein markers of venous return were higher for all conditions compared to CON (p < 0.05), with TIGHTS values also higher compared to SOCKS (p < 0.05). Gastrocnemius medialis blood flow was higher for TIGHTS compared to CON (p = 0.000), SOCKS (p = 0.012), and SHORTS (p = 0.000), with SOCKS higher compared to SHORTS (p = 0.046). Vastus lateralis blood flow was higher for TIGHTS compared to CON (p = 0.028) and SOCKS (p = 0.019), with SHORTS also higher compared to CON (p = 0.012) and SOCKS (p = 0.005). Gastrocnemius medialis oxygenation was higher for TIGHTS compared to CON (p = 0.003), SOCKS (p = 0.033), and SHORTS (p = 0.003), with SOCKS higher compared to CON (p = 0.044) and SHORTS (p = 0.032). Vastus lateralis oxygenation was higher for TIGHTS compared to CON (p = 0.020) and SOCKS (p = 0.006). CONCLUSION Markers of venous return, muscle blood flow, and muscle oxygenation are increased with sports compression garments. TIGHTS are most effective, potentially because of the larger body area compressed.
Collapse
Affiliation(s)
- Shane F O'Riordan
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia.
| | - Rod McGregor
- Faculty of Health, University of Canberra, Bruce, ACT 2617, Australia
| | - Shona L Halson
- School of Behavioural and Health Sciences, Australian Catholic University, Banyo, QLD 4014, Australia
| | - David J Bishop
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia
| | - James R Broatch
- Institute for Health and Sport (iHeS), Victoria University, Footscray, VIC 3011, Australia; Department of Physiology, Australian Institute of Sport, Bruce, ACT 2617, Australia
| |
Collapse
|
5
|
Broatch JR, O'Riordan SF, Keske MA, Betik AC, Bishop DJ, Halson SL, Parker L. Reduced post-exercise muscle microvascular perfusion with compression is offset by increased muscle oxygen extraction: Assessment by contrast-enhanced ultrasound. FASEB J 2021; 35:e21499. [PMID: 33811697 DOI: 10.1096/fj.202002205rr] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Revised: 02/16/2021] [Accepted: 02/17/2021] [Indexed: 11/11/2022]
Abstract
The microvasculature is important for both health and exercise tolerance in a range of populations. However, methodological limitations have meant changes in microvascular blood flow are rarely assessed in humans during interventions designed to affect skeletal muscle blood flow such as the wearing of compression garments. The aim of this study is, for the first time, to use contrast-enhanced ultrasound to directly measure the effects of compression on muscle microvascular blood flow alongside measures of femoral artery blood flow and muscle oxygenation following intense exercise in healthy adults. It was hypothesized that both muscle microvascular and femoral artery blood flows would be augmented with compression garments as compared with a control condition. Ten recreationally active participants completed two repeated-sprint exercise sessions, with and without lower-limb compression tights. Muscle microvascular blood flow, femoral arterial blood flow (2D and Doppler ultrasound), muscle oxygenation (near-infrared spectroscopy), cycling performance, and venous blood samples were measured/taken throughout exercise and the 1-hour post-exercise recovery period. Compared with control, compression reduced muscle microvascular blood volume and attenuated the exercise-induced increase in microvascular velocity and flow immediately after exercise and 1 hour post-exercise. Compression increased femoral artery diameter and augmented the exercise-induced increase in femoral arterial blood flow during exercise. Markers of blood oxygen extraction in muscle were increased with compression during and after exercise. Compression had no effect on blood lactate, glucose, or exercise performance. We provide new evidence that lower-limb compression attenuates the exercise-induced increase in skeletal muscle microvascular blood flow following exercise, despite a divergent increase in femoral artery blood flow. Decreased muscle microvascular perfusion is offset by increased muscle oxygen extraction, a potential mechanism allowing for the maintenance of exercise performance.
Collapse
Affiliation(s)
- James R Broatch
- Institute for Health and Sport (IHES), Victoria University, Melbourne, VIC, Australia.,Australia Institute of Sport, Canberra, ACT, Australia
| | - Shane F O'Riordan
- Institute for Health and Sport (IHES), Victoria University, Melbourne, VIC, Australia.,Australia Institute of Sport, Canberra, ACT, Australia
| | - Michelle A Keske
- Institute for Physical Activity and Nutrition (IPAN), School of Exercise and Nutrition Sciences, Deakin University, Geelong, VIC, Australia
| | - Andrew C Betik
- Institute for Physical Activity and Nutrition (IPAN), School of Exercise and Nutrition Sciences, Deakin University, Geelong, VIC, Australia
| | - David J Bishop
- Institute for Health and Sport (IHES), Victoria University, Melbourne, VIC, Australia
| | - Shona L Halson
- School of Behavioural and Health Sciences, Australian Catholic University, Melbourne, VIC, Australia
| | - Lewan Parker
- Institute for Physical Activity and Nutrition (IPAN), School of Exercise and Nutrition Sciences, Deakin University, Geelong, VIC, Australia
| |
Collapse
|
6
|
Customised pressure profiles of made-to-measure sports compression garments. SPORTS ENGINEERING 2021. [DOI: 10.1007/s12283-021-00350-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
AbstractThe purpose of this study was to make made-to-measure compression garments that elicit pressures within and below clinical standards. The study also examined whether pressures and gradients can be replicated within and between participants’ legs, and between separate compression garment conditions. Ten males volunteered to participate. Based on three-dimensional scans of the participants’ lower body, three different made-to-measure garments were manufactured: control, symmetrical and asymmetrical. Garment pressures were assessed from the malleolus to the gluteal fold using a pressure monitoring device. A root mean squared difference analysis was used to calculate the in vivo linear graduation parameters. Linear regression showed that peak pressure at the ankle in the left and right leg were: control garment, 13.5 ± 2.3 and 12.9 ± 2.6; asymmetrical garment, 12.7 ± 2.5 and 26.3 ± 3.4; symmetrical garment, 27.7 ± 2.2 and 27.5 ± 1.6 (all mmHg, mean ± standard deviation). Pressure reduction from the ankle to the gluteal fold in the left and right leg were: control, 8.9 ± 3.5 and 7.4 ± 3.0; asymmetrical, 7.8 ± 3.9 and 21.9 ± 3.2; symmetrical, 25.0 ± 4.1 and 22.3 ± 3.6 (all mmHg, mean ± standard deviation). Made-to-measure compression garments can be made to elicit pressures within and below clinical standards, and to elicit equivalent pressures and gradients in different participants.
Collapse
|
7
|
Enhanced Cycling Time-Trial Performance During Multiday Exercise With Higher-Pressure Compression Garment Wear. Int J Sports Physiol Perform 2020; 16:287-295. [PMID: 32871554 DOI: 10.1123/ijspp.2019-0716] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2019] [Revised: 03/23/2020] [Accepted: 04/03/2020] [Indexed: 11/18/2022]
Abstract
PURPOSE Compression garments are widely used as a tool to accelerate recovery from intense exercise and have also gained traction as a performance aid, particularly during periods of limited recovery. This study tested the hypothesis that increased pressure levels applied via high-pressure compression garments would enhance "multiday" exercise performance. METHODS A single-blind crossover design, incorporating 3 experimental conditions-loose-fitting gym attire (CON), low-compression (LC), and high-compression (HC) garments-was adopted. A total of 10 trained male cyclists reported to the laboratory on 6 occasions, collated into 3 blocks of 2 consecutive visits. Each "block" consisted of 3 parts, an initial high-intensity protocol, a 24-hour period of controlled rest while wearing the applied condition/garment (CON, LC, and HC), and a subsequent 8-km cycling time trial, while wearing the respective garment. Subjective discomfort questionnaires and blood pressure were assessed prior to each exercise bout. Power output, oxygen consumption, and heart rate were continuously measured throughout exercise, with plasma lactate, creatine kinase, and myoglobin concentrations assessed at baseline and the end of exercise, as well as 30 and 60 minutes postexercise. RESULTS Time-trial performance was significantly improved during HC compared with both CON and LC (HC = 277 [83], CON = 266 [89], and LC = 265 [77] W; P < .05). In addition, plasma lactate was significantly lower at 30 and 60 minutes postexercise on day 1 in HC compared with CON. No significant differences were observed for oxygen consumption, heart rate, creatine kinase, or subjective markers of discomfort. CONCLUSION The pressure levels exerted via lower-limb compression garments influence their effectiveness for cycling performance, particularly in the face of limited recovery.
Collapse
|
8
|
Shaari IH, Abu Osman NA, Shasmin HN. A case study on interface pressure pattern of two garment orthoses on a child with cerebral palsy. Proc Inst Mech Eng H 2020; 234:884-894. [DOI: 10.1177/0954411920923541] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Many studies have shown that medical compression products produce different levels of interface pressure during the usage of the products. However, limited studies have explored the pattern of interface pressure exerted by orthotic garments. This case study aimed to investigate the pattern of interface pressure exerted by two types of orthotic garments on a child with cerebral palsy. A 13-year-old child diagnosed with ataxic spastic diplegia cerebral palsy has difficulty to perform sit-to-stand motion even with a walking frame due to his truncal ataxia. A TheraTogsTM orthosis and a Dynamic Lycra® Fabric Orthosis (DLFO) were prepared for the child. The child’s sit-to-stand ability without and with the usage of orthoses was recorded using five sit-to-stand tests. The garments’ interface pressure was measured using F-scan (9811E) and F-scan 6.5.1 version software. The pressure was recorded when the child was in sitting position and performing sit-to-stand-to-sit motion. Overall, the child completed the five sit-to-stand test duration within 2.53 ± 0.04 s and 2.51 ± 0.09 s with the usage of TheraTogsTM orthosis and DLFO, respectively. Higher pressure was exerted by Dynamic Lycra Fabric Orthosis (axillary = 122 mmHg) in contrast to TheraTogsTM orthosis (77 mmHg) when the child was in a sitting position. Lower pressure was exerted by DLFO (7 mmHg), over xiphoid level and for TheraTogsTM orthosis is 1.2 mmHg over axillary level when the child was performing sit-to-stand motion. The largest range of pressure was exerted by TheraTogsTM orthosis with a minimum pressure of 5 mmHg and a maximum pressure of 155 mmHg during sit-to-stand motion. Overall, the DLFO exerted higher mean interface pressure on the child in comparison to TheraTogsTM orthosis when the child’s body was in a sitting position wearing both upper garment and pants. Both TheraTogsTM orthosis and DLFO presented a different range of interface pressure over different body segments and activities.
Collapse
Affiliation(s)
- Ida Hasni Shaari
- Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
- Centre of Physiotherapy Study, Faculty of Health Sciences, Universiti Teknologi MARA, Puncak Alam, Selangor, Malaysia
| | - Noor Azuan Abu Osman
- Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| | - Hanie Nadia Shasmin
- Centre for Applied Biomechanics, Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
| |
Collapse
|
9
|
Effects of Upper-Limb, Lower-Limb, and Full-Body Compression Garments on Full Body Kinematics and Free-Throw Accuracy in Basketball Players. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10103504] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Compression garments can enhance performance and promote recovery in athletes. Different body coverage with compression garments may impose distinct effects on kinematic movement mechanics and thus basketball free-throw accuracy. The objective of this study was to examine basketball free-throw shooting accuracy, consistency and the range of motion of body joints while wearing upper-, lower- and full-body compression garments. Twenty male basketball players performed five blocks of 20 basketball free-throw shooting trials in each of the following five compression garment conditions: control-pre, top, bottom, full (top + bottom) and control-post. All conditions were randomized except pre- and post-control (the first and last conditions). Range of motion of was acquired by multiple inertial measurement units. Free-throw accuracy and the coefficient of variation were also analyzed. Players wearing upper-body or full-body compression garments had significantly improved accuracy by 4.2% and 5.9%, respectively (p < 0.05), but this difference was not observed with shooting consistency. Smaller range of motion of head flexion and trunk lateral bending (p < 0.05) was found in the upper- and full-body conditions compared to the control-pre condition. These findings suggest that an improvement in shooting accuracy could be achieved by constraining the range of motion through the use of upper-body and full-body compression garments.
Collapse
|
10
|
Effects of Compression Tights on Recovery Parameters after Exercise Induced Muscle Damage: A Randomized Controlled Crossover Study. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2019; 2019:5698460. [PMID: 30728847 PMCID: PMC6341249 DOI: 10.1155/2019/5698460] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Revised: 12/13/2018] [Accepted: 01/01/2019] [Indexed: 01/16/2023]
Abstract
Introduction Recent meta-analyses on compression garments have reported faster recovery of muscle function particularly after intense eccentric power or resistance exercise. However, due to the complex interaction between cohorts included, exercises involved and compression applied, recovery length and modalities, and outcome parameters selected, only limited practical recommendations can be drawn from these studies. Thus, our aim was to determine the effect of compression tights on recovery from high mechanical and metabolic stress monitored over a longer recovery period. Material and Methods Using a crossover design, 19 resistance-trained 4th/5th Division German handball players (31.3±7.7 years; 24.1±3.8 kg/m2) were randomly assigned at the start of the project to the compression tight (recovery-pro-tights, cep, Bayreuth, Germany) or the control group. Immediately after a combined lower extremity resistance training and electromyostimulation, participants had to wear compression tights. Compression was applied initially for 24 h and then 12 h intermitted by 12 h of nonuse for a total of 96 h. Primary study endpoint was maximum isokinetic hip/leg-extensor strength (MIES) as determined by a leg-press. Secondary endpoint was lower extremity power as assessed by a counter movement jump. Follow-up assessments were conducted 24, 48, 72, and 96 h postexercise. Outcomes were analyzed using a linear mixed effect model with spherical symmetric within-condition correlation. Results All 19 participants underwent their allocated treatment and passed through the project strictly according to the study protocol. MIES demonstrated significantly (p=0.003) lower overall reductions (155 N) after wearing compression tights. In parallel, lower extremity power significantly (p<0.001) varies between both conditions with lower reductions in favor of the compression condition. Of importance, full recovery for lower extremity muscle strength or power was still not reached 96 h postexercise. Conclusion Based on our results we recommend athletes wear compression tights for faster recovery, particularly after intense exercise with a pronounced eccentric aspect.
Collapse
|
11
|
Snowdon N, Sier D, Potia T, Wheat J, McLean S. Compression garments and fabric orthoses for rehabilitation and function: a systematic mapping review. INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION 2018. [DOI: 10.12968/ijtr.2018.25.12.655] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Nicky Snowdon
- Senior lecturer in physiotherapy, Department of Allied Health Professions, Faculty of Health and Wellbeing, Sheffield Hallam University, Sheffield, UK
| | - Daniel Sier
- Physiotherapy clinical specialist, Neuro Rehabilitation Outreach Team, Rotherham, Doncaster and South Humber NHS Foundation Trust, Doncaster, UK
| | - Tanzila Potia
- Staff physical therapist, Atlantis Physical Therapy, Roxbury, Massachusetts, USA
| | - Jon Wheat
- Professor of Sport and Exercise Biomechanics, Academy of Sport and Physical Activity Sheffield Hallam University, Sheffield, UK
| | - Sionnadh McLean
- Senior lecturer in physiotherapy, Department of Allied Health Professions, Sheffield Hallam University, Sheffield, UK
| |
Collapse
|
12
|
Lee DC, Lee SW, Khaw K, Ali A, Sheridan SE, Wong SH. Haemodynamic responses of wearing low-pressure sports compression tights during an orthostatic challenge in healthy individuals. J Sci Med Sport 2018; 21:1062-1067. [DOI: 10.1016/j.jsams.2017.12.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2017] [Revised: 11/16/2017] [Accepted: 12/08/2017] [Indexed: 10/18/2022]
|
13
|
Lower Limb Sports Compression Garments Improve Muscle Blood Flow and Exercise Performance During Repeated-Sprint Cycling. Int J Sports Physiol Perform 2018; 13:882-890. [DOI: 10.1123/ijspp.2017-0638] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Purpose: Evidence supporting the use of lower-limb compression garments during repeated-sprint exercise (RSE) with short rest periods, where performance will rely heavily on aerobic metabolism, is lacking. Methods: A total of 20 recreationally active participants completed 2 cycling RSE sessions, with and without lower-limb compression tights. The RSE session consisted of 4 sets of 10 × 6-s maximal sprints on a wind-braked cycle ergometer, interspaced by 24 s of recovery between bouts and 2 min of recovery between sets. Muscle oxygen consumption () of, and blood flow (mBF) to, the right vastus lateralis muscle was measured during exercise using near-infrared spectroscopy and venous/arterial occlusions of the right lower limb. Cycling performance, oxygen consumption (), heart rate, and capillary blood samples (lactate, pH, bicarbonate, and base excess) were also measured/taken throughout the session. Results: Compared with control, peak power (40.7 [19.9] W; mean ± 95% confidence intervals) and mBF (0.101 [0.061] mL·min−1·100 g−1) were higher, and heart rate (2 [1] beats/min) was lower, when participants wore compression (P < .05). , , blood lactate, and heart rate increased as a result of exercise (P < .05), with no differences between conditions. Similarly, blood pH, bicarbonate, and base excess decreased as a result of exercise (P < .05), with no difference between conditions. Conclusions: Wearing lower-limb compression tights during RSE with short intervals of rest improved cycling performance, vastus lateralis mBF, and heart rate. These results provide novel data to support the notion that lower-limb compression garments aid RSE performance, which may be related to local and/or central blood flow.
Collapse
|
14
|
Reich-Schupke S, Surhoff S, Stücker M. Pressure profiles of sport compression stockings. J Dtsch Dermatol Ges 2018; 14:495-506. [PMID: 27119471 DOI: 10.1111/ddg.12779] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
BACKGROUND While sport compression stockings (SCS) have become increasingly popular, there is no regulatory norm as exists for medical compression stockings (MCS). The objective of this pilot study was to compare five SCS with respect to their pressure profiles ex vivo and in vivo, and in relation to German standards for MCS (RAL norm). PATIENTS AND METHODS In vivo (10 competitive athletes; standardized procedure using the Kikuhime pressure monitor) and ex vivo (tested at the Hohenstein Institute) pressure profiles were tested for the following products: CEP Running Progressive Socks, Falke Running Energizing, Sigvaris Performance, X-Socks Speed Metal Energizer, and 2XU Compression Race Socks. RESULTS Ex vivo ankle pressures of CEP (25.6 mmHg) and 2XU (23.2 mmHg) corresponded to class 2 MCS; that of Sigvaris (20.8 mmHg), to class 1 MCS. The remaining SCS achieved lower pressure values. The pressure gradients showed marked differences, and did not meet MCS standards. Average in vivo pressures were higher for 2XU, CEP, and Sigvaris than for Falke and X-Socks. However, in vivo values for all SCS were below those of class 1 MCS. None of the SCS showed the decreasing pressure gradient (from distal to proximal) required for MCS. CONCLUSIONS In vivo and ex vivo pressure profiles of all SCS examined showed marked heterogeneity, and did not meet MCS standards. Consequently, the clinical and practical effects of SCS cannot be compared, either. It would therefore be desirable to establish a classification that allows for the categorization and comparison of various SCS as well as their selection based on individual preferences and needs (high vs. low pressure, progressive vs. degressive profile).
Collapse
Affiliation(s)
- Stefanie Reich-Schupke
- Center for Venous Disorders (Dermatology and Vascular Surgery), Department of Dermatology, Allergology, und Venereology, University of Bochum, St. Josef Hospital, Bochum, Germany
| | - Stefan Surhoff
- Center for Venous Disorders (Dermatology and Vascular Surgery), Department of Dermatology, Allergology, und Venereology, University of Bochum, St. Josef Hospital, Bochum, Germany
| | - Markus Stücker
- Center for Venous Disorders (Dermatology and Vascular Surgery), Department of Dermatology, Allergology, und Venereology, University of Bochum, St. Josef Hospital, Bochum, Germany
| |
Collapse
|
15
|
Rahimi M, Blaber AP, Menon C. Motorized adaptive compression system for enhancing venous return: A feasibility study on healthy individuals. Med Eng Phys 2017; 50:65-74. [PMID: 29102275 DOI: 10.1016/j.medengphy.2017.10.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2017] [Revised: 08/18/2017] [Accepted: 10/04/2017] [Indexed: 10/18/2022]
Abstract
Notwithstanding the extensive use of conventional compression devices in managing venous disorders, these modalities have shortages that diminish their treatment efficacy and lessen patient adherence to therapy. The purpose of this study was to develop an improved compression system that eliminates the flaws of the existing devices. A motorized bandage was designed that takes advantage of continuous feedback from force-sensing resistors to apply reproducible, controlled pressure on the lower extremities. The performance of the device in enhancing venous return was explored in a pilot test on 11 healthy participants, wherein graded lower body negative pressure was employed as a surrogate of passive standing. Each subject underwent two experiments; with and without pressure application over the calves. A two-way repeated-measures analysis of variance revealed a significant difference in the mean hemodynamic responses when the compression bandage was in action (p < .05). Specifically, a meaningful increase was observed in mean arterial pressure by 5%, diastolic blood pressure by 8% and left ventricular ejection time by 4%; and a significant decrease of 5% and 6% was noticed in heart rate and pulse pressure, respectively. These results demonstrate the capability of the designed system in attenuating the imposed orthostatic stress on cardiovascular system.
Collapse
Affiliation(s)
- Mahan Rahimi
- MENRVA Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University, Metro Vancouver, BC V3T 0A3, Canada
| | - Andrew P Blaber
- Aerospace Physiology Laboratory, Department of Biomedical Physiology and Kinesiology, Simon Fraser University, Burnaby, BC V5A 1S6, Canada
| | - Carlo Menon
- MENRVA Research Group, Schools of Mechatronic Systems Engineering and Engineering Science, Simon Fraser University, Metro Vancouver, BC V3T 0A3, Canada.
| |
Collapse
|
16
|
de Britto MA, Lemos AL, Dos Santos CS, Stefanyshyn DJ, Carpes FP. Effect of a Compressive Garment on Kinematics of Jump-Landing Tasks. J Strength Cond Res 2016; 31:2480-2488. [PMID: 27552212 DOI: 10.1519/jsc.0000000000001620] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
de Britto, MA, Lemos, AL, dos Santos, CS, Stefanyshyn, DJ, and Carpes, FP. Effect of a compressive garment on kinematics of jump-landing tasks. J Strength Cond Res 31(9): 2480-2488, 2017-During jump-landing tasks, knee kinematics such as excessive valgus have been linked to knee injury in females. We determine the influence of a compressive garment on knee valgus during landing. Physically active women (n = 27, mean age 23 years) performed 4 different jump-landing tasks with 2 apparel conditions (compressive garment and regular sports shorts). Kinematic data were collected to determine knee flexion and valgus angles and the maximum jump height. Results showed that the compressive garment decreased knee flexion and knee valgus range of motion, without significant changes in the maximum jump height. As a practical application, we suggest that compression could be a strategy to reduce dynamic valgus without influencing jump performance, which motivates further study of its potential for knee injury prevention.
Collapse
Affiliation(s)
- Morgana A de Britto
- 1Laboratory of Neuromechanics, Applied Neuromechanics Research Group, Federal University of Pampa, Uruguaiana, Rio Grande do Sul, Brazil; 2Post-Graduate Program in Physical Education, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil; and 3Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, Alberta, Canada
| | | | | | | | | |
Collapse
|
17
|
Reich-Schupke S, Surhoff S, Stücker M. Das Druckprofil von Sportkompressionsstrümpfen. J Dtsch Dermatol Ges 2016; 14:495-507. [DOI: 10.1111/ddg.12779_g] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Stefanie Reich-Schupke
- Venenzentrum der Dermatologischen und Gefäßchirurgischen Kliniken, Klinik für Dermatologie, Allergologie und Venerologie; Kliniken der Ruhr-Universität Bochum im St. Josef Krankenhaus; Bochum
| | - Stefan Surhoff
- Venenzentrum der Dermatologischen und Gefäßchirurgischen Kliniken, Klinik für Dermatologie, Allergologie und Venerologie; Kliniken der Ruhr-Universität Bochum im St. Josef Krankenhaus; Bochum
| | - Markus Stücker
- Venenzentrum der Dermatologischen und Gefäßchirurgischen Kliniken, Klinik für Dermatologie, Allergologie und Venerologie; Kliniken der Ruhr-Universität Bochum im St. Josef Krankenhaus; Bochum
| |
Collapse
|
18
|
Wannop JW, Worobets JT, Madden R, Stefanyshyn DJ. Influence of Compression and Stiffness Apparel on Vertical Jump Performance. J Strength Cond Res 2016; 30:1093-101. [PMID: 27003453 DOI: 10.1519/jsc.0000000000001195] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Compression apparel alters both compression of the soft tissues and the hip joint stiffness of athletes. It is not known whether it is the compression elements, the stiffness elements, or some combination that increases performance. Therefore, the purpose of this study was to determine how systematically increasing upper leg compression and hip joint stiffness independently from one another affects vertical jumping performance. Ten male athletes performed countermovement vertical jumps in 8 concept apparel conditions and 1 control condition (loose fitting shorts). The 8 apparel conditions, 4 that specifically altered the amount of compression exerted on the thigh and 4 that altered the hip joint stiffness by means of elastic thermoplastic polyurethane bands, were tested on 2 separate testing sessions (one testing the compression apparel and the other testing the stiffness apparel). Maximum jump height was measured, while kinematic data of the hip, knee, and ankle joint were recorded with a high-speed camera (480 Hz). Both compression and stiffness apparel can have a positive influence on vertical jumping performance. The increase in jump height for the optimal compression was due to increased hip joint range of motion and a trend of increasing the jump time. Optimal stiffness also increased jump height and had the trend of decreasing the hip joint range of motion and hip joint angular velocity. The exact mechanisms by which apparel interventions alter performance is not clear, but it may be due to alterations to the force-length and force-velocity relationships of muscle.
Collapse
Affiliation(s)
- John W Wannop
- Human Performance Lab, Faculty of Kinesiology, University of Calgary, Calgary, Alberta, Canada
| | | | | | | |
Collapse
|
19
|
Chan V, Duffield R, Watsford M. The effects of compression garments on performance of prolonged manual-labour exercise and recovery. Appl Physiol Nutr Metab 2016; 41:125-32. [DOI: 10.1139/apnm-2015-0335] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
This study investigated the effects of wearing compression garments during and 24 h following a 4-h exercise protocol simulating manual-labour tasks. Ten physically trained male participants, familiar with labouring activities, undertook 4 h of work tasks characteristic of industrial workplaces. Participants completed 2 testing sessions, separated by at least 1 week. In the experimental condition, participants wore a full-length compression top and compression shorts during the exercise protocol and overnight recovery, with normal work clothes worn in the control condition. Testing for serum creatine kinase and C-reactive protein, handgrip strength, knee flexion and extension torque, muscle stiffness, perceived muscle soreness and fatigue as well as heart rate and rating of perceived exertion (RPE) responses to 4-min cycling were performed before, following, and 24 h after exercise. Creatine kinase, muscle soreness, and rating of perceived fatigue increased following the exercise protocol (p < 0.05) as did RPE to a standardised cycling warm-up bout. Conversely, no postexercise changes were observed in C-reactive protein, handgrip strength, peak knee flexion torque, or stiffness measures (p > 0.05). Knee extension torque was significantly higher in the control condition at 24 h postexercise (3.1% ± 5.4% change; compression: 2.2% ± 11.1% change), although no other variables were different between conditions at any time. However, compression demonstrated a moderate–large effect (d > 0.60) to reduce perceived muscle soreness, fatigue, and RPE from standardised warm-up at 24 h postexercise. The current findings suggest that compression may assist in perceptual recovery from manual-labour exercise with implications for the ability to perform subsequent work bouts.
Collapse
Affiliation(s)
- Val Chan
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
| | - Rob Duffield
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
| | - Mark Watsford
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
- Sport and Exercise Discipline Group, Faculty of Health, University of Technology Sydney, Lindfield, Australia
| |
Collapse
|
20
|
Marqués-Jiménez D, Calleja-González J, Arratibel I, Delextrat A, Terrados N. Are compression garments effective for the recovery of exercise-induced muscle damage? A systematic review with meta-analysis. Physiol Behav 2016; 153:133-48. [DOI: 10.1016/j.physbeh.2015.10.027] [Citation(s) in RCA: 47] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2015] [Revised: 10/22/2015] [Accepted: 10/26/2015] [Indexed: 10/22/2022]
|