1
|
Shimizu T, Tsuchiya Y, Ueda H, Izumi S, Ochi E. Effects of single and repeated bouts of flywheel exercise on jump performance and muscle damage in athletes and non athletes. BMC Sports Sci Med Rehabil 2024; 16:9. [PMID: 38167075 PMCID: PMC10763137 DOI: 10.1186/s13102-023-00785-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Accepted: 12/07/2023] [Indexed: 01/05/2024]
Abstract
BACKGROUND Although recent studies have investigated the effects of flywheel (FW) training on muscle function, the effects of transient FW exercise on jump performance in athletes are unknown. This study examined the effects of single and repeated bouts of FW squat exercises on jump performance and muscle damage in male collegiate basketball players. METHODS The participants were 10 healthy college-age men (nonathletes) and 11 male basketball players (athletes). The intervention involved 100 squat exercises (10 repetitions × 10 sets) using an FW device. To examine the repeated-bout effects, the protocol was conducted again after a 2-week interval. Squat jumps, countermovement jumps, drop jumps, and rebound jumps were evaluated as jump performance, while isometric maximal voluntary contraction (MVC) torque in knee extension, muscle soreness, range of motion, thigh circumference, muscle thickness, and echo intensity were evaluated as markers of muscle damage. Measurements were taken at baseline, immediately after exercise, 24 h later, and 72 h later. RESULTS The jump performance of nonathletes decreased after exercise (p < 0.05), while that of the athletes did not. The results were similar for muscle soreness. MVC torque decreased significantly after the first exercise in both groups (p < 0.05) and was significantly lower in the nonathletes versus athletes. Significant repeated-bout effects were found for muscle soreness in nonathletes but not athletes. CONCLUSIONS These results suggest that a single bout of FW exercise reduces jump performance in male nonathletes but not basketball players.
Collapse
Affiliation(s)
- Takashi Shimizu
- Faculty of Health Care, Teikyo Heisei University, 2-51-4, Higashiikebukuro, Toshima, Tokyo, 170-8445, Japan
- Graduate School of Sports and Health Studies, Hosei University, 4342, Aihara-Cho, Machida, Tokyo, 194-0298, Japan
| | - Yosuke Tsuchiya
- Center for Liberal Arts, Laboratory of Health and Sports Sciences, Meiji Gakuin University, 1518, Kamikurata-Cho, Totsuka, Yokohama, Kanagawa, 244-8539, Japan
| | - Hisashi Ueda
- Faculty of Health and Medical Science, Teikyo Heisei University, 4-1, Uruidominami, Ichihara, Chiba, 290-0193, Japan
| | - Shigeki Izumi
- Graduate School of Sports and Health Studies, Hosei University, 4342, Aihara-Cho, Machida, Tokyo, 194-0298, Japan
| | - Eisuke Ochi
- Graduate School of Sports and Health Studies, Hosei University, 4342, Aihara-Cho, Machida, Tokyo, 194-0298, Japan.
- Faculty of Bioscience and Applied Chemistry, Graduate School of Sports and Health Studies, Hosei University, 3-7-2 Kajino, Koganei, Tokyo, 184-8584, Japan.
| |
Collapse
|
2
|
Thompson BJ, Xu J. Isokinetic Dynamometer Leg Extensor Peak Torque Measurement: A Time-Delayed Reliability and Score Selection Analysis Study. J Funct Morphol Kinesiol 2023; 8:jfmk8020062. [PMID: 37218858 DOI: 10.3390/jfmk8020062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Revised: 04/21/2023] [Accepted: 05/09/2023] [Indexed: 05/24/2023] Open
Abstract
The reliability of isokinetic peak torque (PT) has been reported mostly using a short-term (<~10 day) inter-trial testing time frame. However, many studies and programs utilize a long-term (several weeks to months) inter-trial testing period. Additionally, the methods by which the PT value is selected and reported from a multiple rep testing scheme have not been well investigated for both reliability and PT absolute performance comparisons. The purpose of this study was to investigate the long-term reliability of isokinetic and isometric PT of the leg extensors with an emphasis on the differences among several PT score selection methods. Thirteen men and women (age = 19.5 years) underwent two testing trials separated by 28.8 (±1.8) days. Testing included maximal voluntary contractions of three sets of three reps for two isokinetic contraction conditions of 60 (Isok60) and 240 (Isok240) deg/s velocities, and three sets of one rep of isometric contractions for the leg extensors. The PT score was derived from seven different methods (see text for descriptions). Reliability as assessed from intraclass correlation coefficients (ICCs) varied widely across contraction conditions and PT score selection parameters. The Isok60 velocity overall had lower reliability (ICCs = 0.48-0.81) than Isok240 (0.77-0.87) across the conditions whereas the isometric PT variables showed moderate reliability (0.71-0.73). Overall the set 1 PT score selection parameters were generally lower (p ≤ 0.05) than those that involved sets two and three. Systematic error (p ≤ 0.05) was shown for 6 out of the 17 PT selection variables. On a subjective interpretation basis, when taking everything into account the best overall combination of time/trial efficiency, reliability, best/highest PT score parameter, and reduced risk of systematic bias appears to be the PT variable that uses the average of the highest two reps of the first two sets of three reps-i.e., averaging the highest two values of the six total reps from the first two sets.
Collapse
Affiliation(s)
- Brennan J Thompson
- Department of Kinesiology and Health Science, Utah State University, Logan, UT 84322, USA
- Movement Research Clinic, Sorenson Legacy Foundation Center for Clinical Excellence, Utah State University, Logan, UT 84322, USA
| | - Jennifer Xu
- Department of Kinesiology, University of Virginia, Charlottesville, VA 22904, USA
| |
Collapse
|