1
|
Wong SW, Kopecny L, Crowe P. Interventions to prevent visual fatigue during robotic surgery. J Robot Surg 2024; 18:396. [PMID: 39509074 DOI: 10.1007/s11701-024-02154-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2024] [Accepted: 10/26/2024] [Indexed: 11/15/2024]
Abstract
The robotic surgeon is at risk of visual fatigue from prolonged viewing of the video display resulting in digital eye strain and use of the three-dimensional binoculars resulting in accommodative stress. Symptoms of digital eye strain include blurred vision, dry eyes, eyestrain, neck and back ache, diplopia, light sensitivity, and headaches. Vergence or accommodation-related symptoms include blurred near or distance vision, difficulty refocusing, and diplopia. Beneficial ergonomic interventions to manage digital eye strain during robotic surgery include appropriate lighting, improved neck positioning, optimal screen positioning, improved image parameters, screen breaks, optimising environmental factors, and eye exercises. Correction of refractive error, use of lubricating eye drops, and blink efficiency training to induce motor memory have been shown to be effective in reducing visual fatigue. Vergence-accommodation mismatch can be reduced with slower movement of the camera, screen breaks, and correction of refractive error. Robotic surgeons should adopt these simple and non-invasive interventions to minimise visual fatigue.
Collapse
Affiliation(s)
- Shing Wai Wong
- Randwick Campus, School of Clinical Medicine, The University of New South Wales, Sydney, NSW, Australia.
- Department of General Surgery, Prince of Wales Hospital, Sydney, NSW, Australia.
| | - Lloyd Kopecny
- Department of General Surgery, Prince of Wales Hospital, Sydney, NSW, Australia
| | - Philip Crowe
- Randwick Campus, School of Clinical Medicine, The University of New South Wales, Sydney, NSW, Australia
- Department of General Surgery, Prince of Wales Hospital, Sydney, NSW, Australia
| |
Collapse
|
2
|
Nagarajan K, Ravi K, Periakaruppan SP, Satgunam P. When noise becomes signal: A study of blink rate using an eye tracker. Ocul Surf 2024; 34:516-520. [PMID: 39491645 DOI: 10.1016/j.jtos.2024.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 10/26/2024] [Accepted: 11/02/2024] [Indexed: 11/05/2024]
Abstract
PURPOSE Although blink rate is considered important for digital eye strain and dry eye conditions, its assessment has been mostly manual. This study aimed at quantifying blink rate automatically using the Eyelink 1000 Plus eye tracker and comparing it with manual counting. Additionally, blink rate was correlated with reading eye movements and reading speed. METHODS Thirty participants (mean age 26.8 ± 3.5 years; 19 females) were enrolled. An on-screen reading task for 3 min duration, was repeated 3 times with a 2-min break between the repetitions. During this task, eye movements and blinks were measured through the Eyelink 1000 Plus eye tracker. The blink was also counted manually by the examiner in real time from a video feed. RESULTS The blink rate obtained by the eye tracker (median [Q1, Q3]:11.7 [6.8,15.5] blinks/min) and manual counting (11.6 [7.1, 15.4] blinks/min) were comparable (p > 0.5). No significant correlations were observed between the blink rate and any of the reading eye movement parameters except saccadic amplitude (Spearman's rho, rs = 0.506). No statistically significant correlation was found between the blink rate and reading speed. CONCLUSION The Eyelink 1000 Plus eye tracker gives a comparable blink rate compared to that obtained through manual counting. A positive correlation between the blink rate and saccade amplitude could indicate a coupled interaction between the two mechanisms to minimize visual loss during reading. The option of using this tracker to investigate blinks in dry eye and binocular vision disorders can be further explored.
Collapse
Affiliation(s)
- Krishnaveni Nagarajan
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India
| | - Kavya Ravi
- Hinsdale Central High School, Hinsdale, IL, USA
| | | | - PremNandhini Satgunam
- Brien Holden Institute of Optometry and Vision Sciences, L V Prasad Eye Institute, Hyderabad, India.
| |
Collapse
|
3
|
Tomberg C, Petagna M, de Selliers de Moranville LA. Spontaneous eye blinks in horses (Equus caballus) are modulated by attention. Sci Rep 2024; 14:19336. [PMID: 39164361 PMCID: PMC11336180 DOI: 10.1038/s41598-024-70141-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Accepted: 08/13/2024] [Indexed: 08/22/2024] Open
Abstract
Spontaneous eye blinks are brief closures of both eyelids. The spontaneous eye blink rate (SEBR) exceeds physiological corneal needs and is modulated by emotions and cognitive states, including vigilance and attention, in humans. In several animal species, the SEBR is modulated by stress and antipredator vigilance, which may limit the loss of visual information due to spontaneous eye closing. Here, we investigated whether the SEBR is modulated by attention in the domestic horse (Equus caballus). Our data supported previous studies indicating a tonic SEBR specific to each individual. We also found that, superimposed on a tonic SEBR, phasic changes were induced by cognitive processing. Attention downmodulated the SEBR, with the magnitude of blink inhibition proportional to the degree of attentional selectivity. On the other hand, reward anticipation upregulated the SEBR. Our data also suggested that horses possess the cognitive property of object permanence: they understand that an object that is no longer in their visual field has not ceased to exist. In conclusion, our results suggested that spontaneous eye blinks in horses are modulated by attentional cognitive processing.
Collapse
Affiliation(s)
- Claude Tomberg
- Faculty of Medicine, Université libre de Bruxelles, 808, route de Lennik, CP 630, 1070, Brussels, Belgium.
| | - Maxime Petagna
- Faculty of Medicine, Université libre de Bruxelles, 808, route de Lennik, CP 630, 1070, Brussels, Belgium
| | | |
Collapse
|
4
|
Acet Y. Assessing blink dynamics with non-noticeable method. Cont Lens Anterior Eye 2024:102277. [PMID: 39004571 DOI: 10.1016/j.clae.2024.102277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2024] [Revised: 07/09/2024] [Accepted: 07/09/2024] [Indexed: 07/16/2024]
Abstract
PURPOSE The purpose of the study was to demonstrate the feasibility of blink dynamics with a contactless, non-noticeable method without any visible light being reflected to the participant's eye by the device, and to investigate the blink dynamics parameters in 39 participants whose blink dynamics were examined with this method. It was also aimed to explain the potential of corneal topography devices for non-noticeable blink dynamics and elucidate some tips to device manufacturers to make them practical. METHODS A one-minute real-time video image in the meibography module of the scheimpflug camera-based corneal topography device was recorded in the slow motion mode of the mobile phone. Detailed analysis of blink dynamics was made by advancing the video images manually at 10 ms intervals. Lid Closing Time (LCT), Lid Opening Time (LOT), third Interblink Interval times (IBI(3)), fifth Interblink Interval times (IBI(5)), Number of Blinks Per Minute (NoB), Number of Complete Blinks Per Minute (NoCB), Number of Incomplete Blinks Per Minute (NoICB) were investigated. RESULTS The average NoB, NoCB, and NoICB (blinks/minute) with ± standard deviation (SD) values were found to be 22.9 ± 14.4; 14.5 ± 12.4 and 8.4 ± 8, respectively. The average IBI(3) time(seconds) with ± SD was measured as 3.4 ± 4.5. The average IBI(5) time (seconds) with ± SD was 3.9 ± 3.7 The average LCT time (milliseconds) with ± SD was found to be 91.9 ± 36.9 in the 4 different blinks analyzed. The average LOT time (milliseconds) with ± SD was found to be 582.6 ± 196.5 in the 3 different blinks analyzed. CONCLUSIONS Blink dynamics can be examined in detail with corneal topography devices in a non-contact, no visible light, and most importantly, non-noticeable manner. Existing video imaging modules of corneal topography devices have the potential to investigate blink dynamics. It is anticipated that the clinical use of blink dynamics, which can be performed practically, will increase, particularly in the monitoring of ocular surface and neurological diseases.
Collapse
Affiliation(s)
- Yakup Acet
- Department of Ophthalmology, Mardin Training and Research Hospital, Mardin, Turkey.
| |
Collapse
|
5
|
Vaughan M, García-Porta N, Tabernero J, Gantes-Nuñez J, Artal P, Pardhan S. Ocular effects of exposure to low-humidity environment with contact lens wear: A pilot study. Ophthalmic Physiol Opt 2024; 44:718-726. [PMID: 38551074 DOI: 10.1111/opo.13308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2023] [Revised: 03/13/2024] [Accepted: 03/16/2024] [Indexed: 05/01/2024]
Abstract
PURPOSE To compare the ocular effects of exposure to a low-humidity environment with and without contact lens (CL) wear using various non-invasive tests. METHODS Fourteen habitual soft CL wearers were exposed to controlled low humidity (5% relative humidity [RH]) in an environmental chamber for 90 min on two separate occasions. First, when wearing their habitual spectacles and then, on a separate visit, when wearing silicone hydrogel CLs that were fitted specifically for this purpose. All participants had adapted to the new CL prior to data collection. Three non-invasive objective measurements were taken at each visit: blinking rate, objective ocular scatter (measured using the objective scatter index) and ocular surface cooling rate (measured using a long-wave infrared thermal camera). At each visit, measurements were taken before the exposure in comfortable environmental conditions (RH: 45%), and after exposure to environmental stress (low humidity, RH: 5%). RESULTS CL wearers showed increased blinking rate (p < 0.005) and ocular scatter (p = 0.03) but similar cooling rate of the ocular surface (p = 0.08) when compared with spectacle wear in comfortable environmental conditions. The exposure to low humidity increased the blinking rate significantly with both types of corrections (p = 0.01). Interestingly, ocular scatter (p = 0.96) and cooling rate (p = 0.73) were not significantly different before and after exposure to low humidity. There were no significant two-way interactions between correction and exposure in any of the measurements. CONCLUSIONS CLs significantly increased the blinking rate, which prevented a quick degradation of the tear film integrity as it was refreshed more regularly. It is hypothesised that the increased blinking rate in CL wearers aids in maintaining ocular scatter quality and cooling rate when exposed to a low-humidity environment. These results highlight the importance of blinking in maintaining tear film stability.
Collapse
Affiliation(s)
- Megan Vaughan
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| | - Nery García-Porta
- Applied Physics Department, Optics and Optometry Faculty, University of Santiago de Compostela, Santiago, Spain
- Institute of Materials (iMATUS), University of Santiago de Compostela, Santiago, Spain
| | - Juan Tabernero
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
- Department of Electromagnetism and Electronics, University of Murcia, Murcia, Spain
| | | | - Pablo Artal
- Laboratorio de Óptica, Centro de Investigación en Óptica y Nanofísica, Campus Espinardo, University of Murcia, Murcia, Spain
| | - Shahina Pardhan
- Vision and Eye Research Institute, School of Medicine, Anglia Ruskin University, Cambridge, UK
| |
Collapse
|
6
|
Ren Y, Wen H, Bai F, Huang B, Wang Z, Zhang S, Pu Y, Le Z, Gong X, Wang L, Chen W, Zheng Q. Comparison of deep learning-assisted blinking analysis system and Lipiview interferometer in dry eye patients: a cross-sectional study. EYE AND VISION (LONDON, ENGLAND) 2024; 11:7. [PMID: 38374153 PMCID: PMC10875838 DOI: 10.1186/s40662-024-00373-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 01/01/2024] [Indexed: 02/21/2024]
Abstract
BACKGROUND Abnormal blinking pattern is associated with ocular surface diseases. However, blink is difficult to analyze due to the rapid movement of eyelids. Deep learning machine (DLM) has been proposed as an optional tool for blinking analysis, but its clinical practicability still needs to be proven. Therefore, the study aims to compare the DLM-assisted Keratograph 5M (K5M) as a novel method with the currently available Lipiview in the clinic and assess whether blinking parameters can be applied in the diagnosis of dry eye disease (DED). METHODS Thirty-five DED participants and 35 normal subjects were recruited in this cross-sectional study. DED questionnaire and ocular surface signs were evaluated. Blinking parameters including number of blinks, number of incomplete blinking (IB), and IB rate were collected from the blinking videos recorded by the K5M and Lipiview. Blinking parameters were individually collected from the DLM analyzed K5M videos and Lipiview generated results. The agreement and consistency of blinking parameters were compared between the two devices. The association of blinking parameters to DED symptoms and signs were evaluated via heatmap. RESULTS In total, 140 eyes of 70 participants were included in this study. Lipiview presented a higher number of IB and IB rate than those from DLM-assisted K5M (P ≤ 0.006). DLM-assisted K5M captured significant differences in number of blinks, number of IB and IB rate between DED and normal subjects (P ≤ 0.035). In all three parameters, DLM-assisted K5M also showed a better consistency in repeated measurements than Lipiview with higher intraclass correlation coefficients (number of blinks: 0.841 versus 0.665; number of IB: 0.750 versus 0.564; IB rate: 0.633 versus 0.589). More correlations between blinking parameters and DED symptoms and signs were found by DLM-assisted K5M. Moreover, the receiver operating characteristic analysis showed the number of IB from K5M exhibiting the highest area under curve of 0.773. CONCLUSIONS DLM-assisted K5M is a useful tool to analyze blinking videos and detect abnormal blinking patterns, especially in distinguishing DED patients from normal subjects. Large sample investigations are therefore warranted to assess its clinical utility before implementation.
Collapse
Affiliation(s)
- Yueping Ren
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Han Wen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Furong Bai
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Binge Huang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Zhenzhen Wang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Shuwen Zhang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Yaojia Pu
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Zhenmin Le
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Xianhui Gong
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China
| | - Lei Wang
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China.
| | - Wei Chen
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China.
| | - Qinxiang Zheng
- National Clinical Research Center for Ocular Diseases, Eye Hospital, Wenzhou Medical University, Wenzhou, 325027, Zhejiang, China.
- The School of Ophthalmology and Optometry, Wenzhou Medical University, 270 Xueyuan West Road, Wenzhou, 325027, Zhejiang, People's Republic of China.
| |
Collapse
|
7
|
Vitor RC, de Carvalho Teixeira JB, Dos Santos KC, Oliveira GMSD, Guedes PEB, da Paixão Sevá A, Gomes Junior DC, Veloso JF, Carlos RSA. Shih-Tzu dogs show alterations in ocular surface homeostasis despite adequate aqueous tear production. Acta Vet Scand 2024; 66:3. [PMID: 38229091 DOI: 10.1186/s13028-024-00724-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 01/03/2024] [Indexed: 01/18/2024] Open
Abstract
BACKGROUND Shih-Tzu dogs are frequently affected by ocular surface disorders such as corneal ulceration and dry eye disease (DED). The aim of this study was to evaluate ocular surface homeostasis in Shih-Tzu dogs that have adequate aqueous production. Twenty-eight dogs were subjected to eyelid blink counting, Schirmer tear test (STT-1), ophthalmic evaluation, tear film break-up time (TBUT), fluorescein test and Masmali tear ferning (TF) grading scale. RESULTS Of the 28 animals evaluated, the median value of incomplete eyelid blinks/min (median = 15.0 blinks/min; Interquartil interval - IQR = 8.7 blinks/min - 19.5 blinks/min) was higher than the complete blinks/min (median = 2.5 blinks/min; IQR = 1.6 blinks/min - 4.3 blinks/min), with statistically significant difference. The Schirmer tear test had a median value of 25.0 mm/min (IQR = 22.7 mm/min - 27.5 mm/min), considered within the normal range for the species. On ophthalmic examination, all dogs had trichiasis of the caruncle and medial lower eyelid entropion. Lagophthalmos was the third most common alteration observed (71.4%; 20/28). The median of TBUT was 4.0 s; (IQR = 3.0 - 6.0 s). All the animals were negative to the fluorescein test and the TFT indicated that the majority of the eyes (51.8%; 29/56) were classified in abnormal grades 3 and 4 according to the Masmali tear ferning (TF) grading scale. CONCLUSIONS Although the Shith-Tzu dogs had STT-1 values within the normal range for the species there was high prevalence of abnormal TFT grades and low TBUT in all dogs, showing that despite adequate aqueous production, these dogs have poor precorneal tear film quality. In addition, the dogs showed few complete eyelid blinks and ophthalmic alterations, promoting poor tear film diffusion. All these findings, isolated or together, can result in DED.
Collapse
Affiliation(s)
- Rebeca Costa Vitor
- Department of Agricultural and Environmental Sciences, State University of Santa Cruz (UESC), Ilhéus-Bahia, Brazil
| | | | - Katharine Costa Dos Santos
- Department of Agricultural and Environmental Sciences, State University of Santa Cruz (UESC), Ilhéus-Bahia, Brazil
| | | | - Paula Elisa Brandão Guedes
- Department of Agricultural and Environmental Sciences, State University of Santa Cruz (UESC), Ilhéus-Bahia, Brazil
| | - Anaiá da Paixão Sevá
- Department of Agricultural and Environmental Sciences, State University of Santa Cruz (UESC), Ilhéus-Bahia, Brazil
| | | | - Jéssica Fontes Veloso
- Department of Veterinary Medicine, Federal University of Western Bahia (UFOB), Barra-Bahia, Brazil
| | | |
Collapse
|
8
|
Shi GL, Pan AP, Hu RL, Zhang YQ, Ma YJ, Yu AY. Preliminary Application of a Continuous Functional Contrast Visual Acuity System in the Assessment of Visual Function in Dry Eye Patients. Transl Vis Sci Technol 2023; 12:6. [PMID: 38054930 PMCID: PMC10702783 DOI: 10.1167/tvst.12.12.6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 10/29/2023] [Indexed: 12/07/2023] Open
Abstract
Purpose To investigate the feasibility and efficacy of a continuous functional contrast visual acuity (CFCVA) system in the assessment of visual function in dry eye disease (DED). Methods Twenty patients with DED and 15 normal controls were recruited. Subjective symptoms were evaluated using the Ocular Surface Disease Index (OSDI) questionnaire, and tear film stability was assessed by a noninvasive corneal topographer. Under natural blinking conditions, the custom-built CFCVA system was used to take serial visual acuity measurements at 100%, 25%, 10%, and 5% contrast for 60 seconds. A 5-minute measurement at a 100% contrast level was defined as the stress test (ST). Mean CFCVA was defined, and visual maintenance ratio (VMR) was the ratio of mean CFCVA divided by baseline visual acuity. Results In both groups, VMR decreased and mean CFCVA (logarithm of the minimum angle of resolution) increased with decreasing optotype contrast (from 100% to 5%). In ST, the ST VMR at the fourth and fifth minutes (VMR54 and VMR55) showed the strongest correlations with OSDI total, ocular symptoms, and vision-related function (-0.646 and -0.598, -0.688 and -0.693, and -0.599 and -0.555, respectively, P < 0.05). VMR54 and VMR55 also demonstrated the best discriminating ability for detecting DED, with areas under the curve of 0.903 and 0.867, respectively. Conclusions Extending the continuous measuring time was more effective for detecting vision-related functional abnormalities in patients with DED than simply decreasing the optotype contrast level. Translational Relevance The proposed CFCVA system and associated parameters offer a potential method for quantifying and interpreting the visual symptoms of DED in clinical care.
Collapse
Affiliation(s)
- Gui-Lian Shi
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - An-Peng Pan
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Rui-Lin Hu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | | | - Yun-Jing Ma
- Tianjin Branch of National Clinical Research Center for Ocular Disease, Tianjin, China
- Tianjin Medical University Eye Hospital, Tianjin, China
| | - A-Yong Yu
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| |
Collapse
|
9
|
Sakakura S, Inagaki E, Ochiai Y, Yamamoto M, Takai N, Nagata T, Higa K, Sato Y, Toshida H, Murat D, Hirayama M, Ogawa Y, Negishi K, Shimmura S. A Comprehensive Assessment of Tear-Film-Oriented Diagnosis (TFOD) in a Dacryoadenectomy Dry Eye Model. Int J Mol Sci 2023; 24:16510. [PMID: 38003700 PMCID: PMC10671533 DOI: 10.3390/ijms242216510] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2023] [Revised: 11/06/2023] [Accepted: 11/13/2023] [Indexed: 11/26/2023] Open
Abstract
Tear film instability is a major cause of dry eye disease. In order to treat patients with short tear film breakup time (TBUT)-type dry eye, the development of tear film stabilizing agents is essential. However, the lack of an appropriate animal model of tear film instability has made drug development difficult. Although rabbit dry eye models have been reported in the past, there are only a few reports that focus on tear film instability. Herein, we assessed the tear film stability of a rabbit dry eye model induced by dacryoadenectomy. A clinical evaluation of the ocular surface, interferometry, and histological assessments of the cornea and conjunctiva were performed. Following the removal of the lacrimal glands, TBUT was shortened significantly, with dimple and random breakup patterns prominently observed. Furthermore, the blink rate in this model increased after dacryoadenectomy, suggesting that this model partially captured the phenotypes of human short TBUT-type dry eye and may be useful as an animal model for investigating potential drug candidates.
Collapse
Affiliation(s)
- Saki Sakakura
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
| | - Emi Inagaki
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
- Department of Physiology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan
- Japan Society for the Promotion of Science, 5-3-1 Kojimachi, Chiyoda-ku, Tokyo 102-0083, Japan
| | - Yuichiro Ochiai
- Kitayama Labes Co., Ltd., 3052-1 Arai, Ina City 396-0025, Japan
| | | | - Naofumi Takai
- Kitayama Labes Co., Ltd., 3052-1 Arai, Ina City 396-0025, Japan
| | - Taeko Nagata
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
| | - Kazunari Higa
- Cornea Center and Eye Bank, Tokyo Dental College Ichikawa General Hospital, 5-11-13 Sugano, Ichikawa 272-8513, Japan;
| | - Yasunori Sato
- Department of Preventive Medicine and Public Health, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan;
| | - Hiroshi Toshida
- Department of Ophthalmology, Juntendo University Shizuoka Hospital, Nagaoka 1129, Izunokuni City 410-2295, Japan;
| | - Dogru Murat
- Department of Ophthalmology, Tsurumi University, 2-1-3 Tsurumi, Yokohama 230-0063, Japan
| | - Masatoshi Hirayama
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
| | - Yoko Ogawa
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
| | - Kazuno Negishi
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
| | - Shigeto Shimmura
- Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan (M.H.); (K.N.)
- Department of Clinical Regenerative Medicine, Fujita Medical Innovation Center, Fujita Health University, Haneda Innovation City Zone A, 1-1-4 Hanedakuko, Ota-ku, Tokyo 144-0041, Japan
| |
Collapse
|
10
|
Ax T, Ganse B, Fries FN, Szentmáry N, de Paiva CS, March de Ribot F, Jensen SO, Seitz B, Millar TJ. Dry eye disease in astronauts: a narrative review. Front Physiol 2023; 14:1281327. [PMID: 37929210 PMCID: PMC10620524 DOI: 10.3389/fphys.2023.1281327] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 10/03/2023] [Indexed: 11/07/2023] Open
Abstract
Long-duration spaceflight can have adverse effects on human health. One of the most common ocular conditions experienced by astronauts is dry eye disease (DED). Symptoms of DED include feelings of eye irritation, eye strain, foreign body sensation and blurred vision. Over 30% of International Space Station expedition crew members reported irritation and foreign body sensation. We reviewed the current literature on the prevalence and mechanisms of DED in astronauts and its potential implications for long-duration spaceflight, including the influence of environmental factors, such as microgravity and fluid shift on tear film physiology in space. DED has negative effects on astronaut performance, which is why there is a need for further research into the pathophysiology and countermeasures. As an in-flight countermeasure, neurostimulation seems to be among the most promising options.
Collapse
Affiliation(s)
- Timon Ax
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
- School of Medicine, Western Sydney University, Sydney, NSW, Australia
| | - Bergita Ganse
- Werner Siemens-Endowed Chair for Innovative Implant Development (Fracture Healing), Departments and Institutes of Surgery, Saarland University, Homburg/Saar, Germany
- Department of Trauma, Hand and Reconstructive Surgery, Departments and Institutes of Surgery, Saarland University, Homburg/Saar, Germany
| | - Fabian N. Fries
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany
| | - Nóra Szentmáry
- Dr. Rolf M. Schwiete Center for Limbal Stem Cell and Aniridia Research, Saarland University, Homburg/Saar, Germany
| | - Cintia S. de Paiva
- Ocular Surface Center, Department of Ophthalmology, Baylor College of Medicine, Cullen Eye Institute, Houston, TX, United States
| | | | - Slade O. Jensen
- School of Medicine, Western Sydney University, Sydney, NSW, Australia
- Antimicrobial Resistance and Mobile Elements Group, Ingham Institute of Applied Medical Research, Sydney, NSW, Australia
| | - Berthold Seitz
- Department of Ophthalmology, Saarland University Medical Center, Homburg/Saar, Germany
| | | |
Collapse
|
11
|
Zhang S, Echegoyen J. Design and Usability Study of a Point of Care mHealth App for Early Dry Eye Screening and Detection. J Clin Med 2023; 12:6479. [PMID: 37892616 PMCID: PMC10607458 DOI: 10.3390/jcm12206479] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2023] [Revised: 09/27/2023] [Accepted: 10/10/2023] [Indexed: 10/29/2023] Open
Abstract
Significantly increased eye blink rate and partial blinks have been well documented in patients with dry eye disease (DED), a multifactorial eye disorder with few effective methods for clinical diagnosis. In this study, a point of care mHealth App named "EyeScore" was developed, utilizing blink rate and patterns as early clinical biomarkers for DED. EyeScore utilizes an iPhone for a 1-min in-app recording of eyelid movements. The use of facial landmarks, eye aspect ratio (EAR) and derivatives enabled a comprehensive analysis of video frames for the determination of eye blink rate and partial blink counts. Smartphone videos from ten DED patients and ten non-DED controls were analyzed to optimize EAR-based thresholds, with eye blink and partial blink results in excellent agreement with manual counts. Importantly, a clinically relevant algorithm for the calculation of "eye healthiness score" was created, which took into consideration eye blink rate, partial blink counts as well as other demographic and clinical risk factors for DED. This 10-point score can be conveniently measured anytime with non-invasive manners and successfully led to the identification of three individuals with DED conditions from ten non-DED controls. Thus, EyeScore can be validated as a valuable mHealth App for early DED screening, detection and treatment monitoring.
Collapse
Affiliation(s)
- Sydney Zhang
- Department of Clinical Research, Westview Eye Institute, San Diego, CA 92129, USA;
| | | |
Collapse
|
12
|
Lange EB, Fink LK. Eye blinking, musical processing, and subjective states-A methods account. Psychophysiology 2023; 60:e14350. [PMID: 37381918 DOI: 10.1111/psyp.14350] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 04/26/2023] [Accepted: 04/29/2023] [Indexed: 06/30/2023]
Abstract
Affective sciences often make use of self-reports to assess subjective states. Seeking a more implicit measure for states and emotions, our study explored spontaneous eye blinking during music listening. However, blinking is understudied in the context of research on subjective states. Therefore, a second goal was to explore different ways of analyzing blink activity recorded from infra-red eye trackers, using two additional data sets from earlier studies differing in blinking and viewing instructions. We first replicate the effect of increased blink rates during music listening in comparison with silence and show that the effect is not related to changes in self-reported valence, arousal, or to specific musical features. Interestingly, but in contrast, felt absorption reduced participants' blinking. The instruction to inhibit blinking did not change results. From a methodological perspective, we make suggestions about how to define blinks from data loss periods recorded by eye trackers and report a data-driven outlier rejection procedure and its efficiency for subject-mean analyses, as well as trial-based analyses. We ran a variety of mixed effects models that differed in how trials without blinking were treated. The main results largely converged across accounts. The broad consistency of results across different experiments, outlier treatments, and statistical models demonstrates the reliability of the reported effects. As recordings of data loss periods come for free when interested in eye movements or pupillometry, we encourage researchers to pay attention to blink activity and contribute to the further understanding of the relation between blinking, subjective states, and cognitive processing.
Collapse
Affiliation(s)
- Elke B Lange
- Department of Music, Max Planck Institute for Empirical Aesthetics, Frankfurt/M, Germany
| | - Lauren K Fink
- Department of Music, Max Planck Institute for Empirical Aesthetics, Frankfurt/M, Germany
- Max Planck NYU Center for Language, Music, & Emotion, Frankfurt/M, Germany
- Department of Psychology, Neuroscience and Behaviour, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
13
|
Oganov A, Yazdanpanah G, Jabbehdari S, Belamkar A, Pflugfelder S. Dry eye disease and blinking behaviors: A narrative review of methodologies for measuring blink dynamics and inducing blink response. Ocul Surf 2023; 29:166-174. [PMID: 37257694 DOI: 10.1016/j.jtos.2023.05.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 04/28/2023] [Accepted: 05/28/2023] [Indexed: 06/02/2023]
Abstract
Dry eye disease (DED) is a leading cause of ophthalmology clinical encounters with prevalence ranging from 8.7% to 64% in various populations. Blinking is an endogenous process to refresh the tear film, clear debris and maintain quality vision. Altered blinking behavior is a common feature of DED and is implicated in the pathology of the disease. However, lack of a comprehensive review on the relationship between altered blinking behavior and DED is notable in the literature. Blinking behavior may be an effect of DED due to an unstable tear film sensitizing a motor response or be its cause due to destabilization of the tear film in conditions such as benign essential blepharospasm. In this comprehensive review, we summarize the current models and theories of tear film dynamics and blinking behavior to better understand their connection to DED and introduce contemporary technologies and measurement tools used in the evaluation and induction of blinking behavior. We also describe future directions of research to better understand the relationship between DED and blinking and explore therapies that address the abnormal blinking component of DED.
Collapse
Affiliation(s)
- Anthony Oganov
- Department of Ophthalmology, Renaissance School of Medicine, Stony Brook, NY, USA
| | - Ghasem Yazdanpanah
- Illinois Eye and Ear Infirmary, Department of Ophthalmology and Visual Sciences, University of Illinois at Chicago, Illinois, USA
| | - Sayena Jabbehdari
- Jones Eye Institute, University of Arkansas for Medical Sciences, Arkansas, USA
| | - Aditya Belamkar
- Indiana University School of Medicine, Indianapolis, IN, USA
| | | |
Collapse
|
14
|
Kim Y, Lew H. Recovery of the Ratio of Closure Time during Blink Time in Lacrimal Passage Intubation. J Clin Med 2023; 12:3631. [PMID: 37297826 PMCID: PMC10253602 DOI: 10.3390/jcm12113631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2023] [Revised: 03/30/2023] [Accepted: 05/22/2023] [Indexed: 06/12/2023] Open
Abstract
(1) Background: We aim to find a novel blink parameter in nasolacrimal duct obstruction (NDO) patients and analyze parameters that could reflect subjective symptoms and objective indicators at the same time through a blink dynamic analysis. (2) Methods A retrospective study was conducted with 34 patients (48 eyes) who underwent lacrimal passage intubation (LPI) and 24 control groups (48 eyes). All patients' blink patterns were measured using an ocular surface interferometer before and after LPI, including total blink (TB) and partial blink (PB) and the blink indices blink time (BT), lid closing time (LCT), closure time (CT), lid opening time (LOT), interblink time (IBT), closing speed (CS) and opening speed (OS). The tear meniscus height (TMH) was measured, and the questionnaire "Epiphora Patient's Quality of Life (E-QOL)," which includes daily activity restriction as well as static and dynamic activities, was completed. (3) Results: Compared to CT and the ratio of CT during BT (CT/BT) in control (89.4 ± 20.0 msec, 13.16%), those in NDOs were longer (140.3 ± 92.0 msec, 20.20%) and were also related to TMH. After LPI, CT and CT/BT were recovered to 85.4 ± 22.07 msec, 13.29% (p < 0.001). CT and CT/BT showed a positive correlation with the E-QOL questionnaire score, particularly with dynamic activities. (4) Conclusions: CT and CT/BT, which are objective indicators associated with subjective symptoms of patients, are considered new blink indices for the evaluation of NDO patients with Munk's score.
Collapse
Affiliation(s)
| | - Helen Lew
- Department of Ophthalmology, Bundang CHA Medical Center, CHA University, Seongnam 13496, Republic of Korea;
| |
Collapse
|
15
|
Huber SE, Martini M, Sachse P. Task-synchronized eye blink modulation neither requires visual stimulation nor active motor response and is modulated by task predictability. Int J Psychophysiol 2023; 187:1-10. [PMID: 36773888 DOI: 10.1016/j.ijpsycho.2023.01.011] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 01/31/2023] [Accepted: 01/31/2023] [Indexed: 02/12/2023]
Abstract
It has been repeatedly shown that temporal task features are reflected in eye blink dynamics during attention tasks. Eye blinks occur with increased likeliness particularly when demands on external attention allocation are low. Both predictive, top-down and reactive, bottom-up processes were shown to be involved in blink regulation. However, whether temporal stimulus prediction is a generally active component of the attention system or rather specific to the visual domain has not been fully elaborated yet. By monitoring eye blinking of 99 students during an auditory attention task and analyzing particularly the dynamics of eye blink onsets relative to stimuli timings, we show here that prediction does, in principle, not require visual stimulation, and is also not merely a consequence of the involvement of manual responses during the task. We further show that both the inclusion of manual response to stimuli and elevated task predictability enhance the prediction component reflected in eye blink dynamics, whereas for the latter we experimentally manipulate objective task predictability by adjusting the frequency dependence of the power spectral densities of the series of inter-stimulus time intervals. This allows us finally to explain why, for specific choices of experimental conditions, the generally active and present prediction component involved in attention can become difficult to detect in non-visual, auditory tasks. Conversely, this comes with the important implication that, if tasks aim for elaborating particularly temporal prediction, distributing stimuli over time such that inter-stimulus-intervals conform to a sample of Gaussian noise represents a specifically unfavorable choice.
Collapse
Affiliation(s)
- Stefan E Huber
- Department of Psychology, University of Innsbruck, Universitätsstraße 5-7, A-6020 Innsbruck, Austria; Institute of Psychology, University of Graz, Universitätsplatz 2, A-8010 Graz, Austria.
| | - Markus Martini
- Department of Psychology, University of Innsbruck, Universitätsstraße 5-7, A-6020 Innsbruck, Austria
| | - Pierre Sachse
- Department of Psychology, University of Innsbruck, Universitätsstraße 5-7, A-6020 Innsbruck, Austria
| |
Collapse
|
16
|
Chidi-Egboka NC, Jalbert I, Chen J, Briggs NE, Golebiowski B. Blink Rate Measured In Situ Decreases While Reading From Printed Text or Digital Devices, Regardless of Task Duration, Difficulty, or Viewing Distance. Invest Ophthalmol Vis Sci 2023; 64:14. [PMID: 36763349 PMCID: PMC9927758 DOI: 10.1167/iovs.64.2.14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/11/2023] Open
Abstract
Purpose To compare blinking measured in situ during various tasks and examine relationships with ocular surface symptoms. The day-to-day repeatability of the blink rate and interblink interval was assessed. Methods Twenty-four students (28.6 ± 6.3 years; 8 male and 16 female) completed six reading tasks (printed text, laptop, TV, smartphone, smartphone at 50% brightness, smartphone with complex text), and two nonreading tasks (conversation, walking) in a randomized cross-over study. Ocular surface symptoms and clinical signs were assessed. The blink rate and interblink interval were measured using a wearable eye tracking headset. Blink parameters were compared across tasks and time (linear mixed model and post hoc comparisons with Bonferroni correction). Associations between blinking, symptoms, ocular surface, and clinical signs were assessed (Spearman's correlation). The smartphone reading task was completed twice to determine the coefficient of repeatability. Results The blink rate was lower (mean 10.7 ± 9.7 blinks/min) and the interblink interval longer (mean 9.6 ± 8.7 seconds) during all reading tasks compared with conversation (mean 32.4 ± 12.4 blinks/min; 1.5 ± 0.6 seconds) and walking (mean 31.3 ± 15.5 blinks/min; 1.9 ± 1.3s) (P < 0.001). There were no significant differences in blink parameters between any of the reading tasks or between conversation and walking. Changes in blinking occurred within 1 minute of starting the task. No associations were evident between blink rate or interblink interval and ocular surface symptoms or signs. The coefficient of repeatability was ±12.4 blinks/min for blink rate and ±18.8 seconds for interblink interval. Conclusions Spontaneous blinking can be measured reliably in situ. The blink rate was decreased and the interblink interval increased during reading compared with conversation and walking. Changes in blinking were immediate, sustained, and not associated with ocular surface symptoms or signs.
Collapse
Affiliation(s)
- Ngozi Charity Chidi-Egboka
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW, Australia
| | - Isabelle Jalbert
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW, Australia
| | - Jiaying Chen
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW, Australia
| | - Nancy E. Briggs
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW, Australia,Mark Wainwright Analytical Centre, UNSW Sydney, Sydney, NSW, Australia
| | - Blanka Golebiowski
- School of Optometry and Vision Science, Faculty of Medicine and Health, UNSW Sydney, Sydney, NSW, Australia
| |
Collapse
|
17
|
Ji Y, Liu S, Hong X, Lu Y, Wu X, Li K, Li K, Liu Y. Advances in artificial intelligence applications for ocular surface diseases diagnosis. Front Cell Dev Biol 2022; 10:1107689. [PMID: 36605721 PMCID: PMC9808405 DOI: 10.3389/fcell.2022.1107689] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Accepted: 12/05/2022] [Indexed: 01/07/2023] Open
Abstract
In recent years, with the rapid development of computer technology, continual optimization of various learning algorithms and architectures, and establishment of numerous large databases, artificial intelligence (AI) has been unprecedentedly developed and applied in the field of ophthalmology. In the past, ophthalmological AI research mainly focused on posterior segment diseases, such as diabetic retinopathy, retinopathy of prematurity, age-related macular degeneration, retinal vein occlusion, and glaucoma optic neuropathy. Meanwhile, an increasing number of studies have employed AI to diagnose ocular surface diseases. In this review, we summarize the research progress of AI in the diagnosis of several ocular surface diseases, namely keratitis, keratoconus, dry eye, and pterygium. We discuss the limitations and challenges of AI in the diagnosis of ocular surface diseases, as well as prospects for the future.
Collapse
Affiliation(s)
- Yuke Ji
- The Laboratory of Artificial Intelligence and Bigdata in Ophthalmology, Affiliated Eye Hospital of Nanjing Medical University, Nanjing, China
| | - Sha Liu
- The Laboratory of Artificial Intelligence and Bigdata in Ophthalmology, Affiliated Eye Hospital of Nanjing Medical University, Nanjing, China
| | - Xiangqian Hong
- Shenzhen Eye Hospital, Jinan University, Shenzhen, China
| | - Yi Lu
- Shenzhen Eye Hospital, Jinan University, Shenzhen, China
| | - Xingyang Wu
- Shenzhen Eye Hospital, Jinan University, Shenzhen, China
| | - Kunke Li
- Shenzhen Eye Hospital, Jinan University, Shenzhen, China,*Correspondence: Yunfang Liu, ; Keran Li, ; Kunke Li,
| | - Keran Li
- The Laboratory of Artificial Intelligence and Bigdata in Ophthalmology, Affiliated Eye Hospital of Nanjing Medical University, Nanjing, China,*Correspondence: Yunfang Liu, ; Keran Li, ; Kunke Li,
| | - Yunfang Liu
- Department of Ophthalmology, First Affiliated Hospital of Huzhou University, Huzhou, China,*Correspondence: Yunfang Liu, ; Keran Li, ; Kunke Li,
| |
Collapse
|
18
|
Zeng W, Lou H, Huang Q, Li K, Liu X, Wu K. Eliciting blinks by transcutaneous electric nerve stimulation improves tear fluid in healthy video display terminal users: A self-controlled study. Medicine (Baltimore) 2022; 101:e31352. [PMID: 36343050 PMCID: PMC9646660 DOI: 10.1097/md.0000000000031352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
We aimed to elicit strong blinks among healthy video display terminal (VDT) users by periorbital transcutaneous electric nerve stimulation (TENS) and evaluate its impact on the tear fluid and visual task. Appropriate TENS conditions were evaluated to evoke strong blinks under minimum discomfort. Seventeen healthy VDT users with noninvasive Keratograph first breakup time (NIKf-BUT) 5-15 s and Ocular Surface Disease Index (OSDI) scores < 15 were recruited in this study. Before the trial, noninvasive Keratograph average breakup time (NIKa-BUT), tear meniscus height (TMH) and OSDI scores were evaluated. Before each TENS session, the volunteers played Tetris while the corresponding blink rate and Tetris scores were recorded. Then, the participants underwent 30 minutes of TENS, which evoked blinking of their right eye 20 times per minute. Tetris scores were evaluated again during TENS. The Tetris scores and corresponding blink rate were assessed after each TENS session while NIKa-BUT, TMH and OSDI scores were recorded after the third and sixth TENS sessions. We found that OSDI scores declined significantly after the sixth TENS (P = .003). The NIKa-BUT of the right eye was promoted after the sixth TENS (P = .02), and the TMH was higher after the third and sixth TENS in both eyes (P = .03, P = .03 for right eyes respectively, P = .01, P = .01 for left eyes respectively). There was no significant difference between the adjusted Tetris scores before and during TENS (P = .12). The blink rate before and after TENS were unaffected after 6 sessions (P = .61). The results indicated that periorbital TENS effectively ameliorated ocular irritation and improved tear secretion and tear film stability by eliciting strong blinks in healthy VDT users without disturbing the visual task.
Collapse
Affiliation(s)
- Weiting Zeng
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Han Lou
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Quanbin Huang
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Kunke Li
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Xiuping Liu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
| | - Kaili Wu
- Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, China
- * Correspondence: Kaili Wu, Zhongshan Ophthalmic Center, State Key Laboratory of Ophthalmology, Sun Yat-sen University, Guangzhou, Guangdong 510060, China (e-mail: )
| |
Collapse
|
19
|
Validating a Portable Device for Blinking Analyses through Laboratory Neurophysiological Techniques. Brain Sci 2022; 12:brainsci12091228. [PMID: 36138962 PMCID: PMC9496691 DOI: 10.3390/brainsci12091228] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 09/02/2022] [Accepted: 09/06/2022] [Indexed: 11/25/2022] Open
Abstract
Blinking analysis contributes to the understanding of physiological mechanisms in healthy subjects as well as the pathophysiological mechanisms of neurological diseases. To date, blinking is assessed by various neurophysiological techniques, including electromyographic (EMG) recordings and optoelectronic motion analysis. We recorded eye-blink kinematics with a new portable device, the EyeStat (Generation 3, blinktbi, Inc., Charleston, SC, USA), and compared the measurements with data obtained using traditional laboratory-based techniques. Sixteen healthy adults underwent voluntary, spontaneous, and reflex blinking recordings using the EyeStat device and the SMART motion analysis system (BTS, Milan, Italy). During the blinking recordings, the EMG activity was recorded from the orbicularis oculi muscles using surface electrodes. The blinking data were analyzed through dedicated software and evaluated with repeated-measure analyses of variance. The Pearson’s product-moment correlation coefficient served to assess possible associations between the EyeStat device, the SMART motion system, and the EMG data. We found that the EMG data collected during the EyeStat and SMART system recordings did not differ. The blinking data recorded with the EyeStat showed a linear relationship with the results obtained with the SMART system (r ranging from 0.85 to 0.57; p ranging from <0.001 to 0.02). These results demonstrate a high accuracy and reliability of a blinking analysis through this portable device, compared with standard techniques. EyeStat may make it easier to record blinking in research activities and in daily clinical practice, thus allowing large-scale studies in healthy subjects and patients with neurological diseases in an outpatient clinic setting.
Collapse
|
20
|
Corneal nerves and their role in dry eye pathophysiology. Exp Eye Res 2022; 222:109191. [PMID: 35850173 DOI: 10.1016/j.exer.2022.109191] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/15/2022] [Accepted: 07/11/2022] [Indexed: 12/11/2022]
Abstract
As the cornea is densely innervated, its nerves are integral not only to its structure but also to its pathophysiology. Corneal integrity depends on a protective tear film that is maintained by corneal sensation and the reflex arcs that control tearing and blinking. Furthermore, corneal nerves promote epithelial growth and local immunoregulation. Thus, corneal nerves constitute pillars of ocular surface homeostasis. Conversely, the abnormal tear film in dry eye favors corneal epithelial and nerve damage. The ensuing corneal nerve dysfunction contributes to dry eye progression, ocular pain and discomfort, and other neuropathic symptoms. Recent evidence from clinical studies and animal models highlight the significant but often overlooked neural dimension of dry eye pathophysiology. Herein, we review the anatomy and physiology of corneal nerves before exploring their role in the mechanisms of dry eye disease.
Collapse
|
21
|
Smartphone gaming induces dry eye symptoms and reduces blinking in school-aged children. Eye (Lond) 2022; 37:1342-1349. [PMID: 35668140 PMCID: PMC9169596 DOI: 10.1038/s41433-022-02122-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 05/20/2022] [Accepted: 05/23/2022] [Indexed: 01/09/2023] Open
Abstract
Purpose Smartphone use by children is rising rapidly, but its ocular surface impact is unknown. This study examined the effect of smartphone use on blinking, symptoms, and tear function in children. Methods Prospective intervention study where 36 children aged 6–15years (14 M:22 F) played games on a smartphone continuously for one hour. Symptoms (SANDE, IOSS, NRS) and tear film (lipid layer thickness, tear secretion, stability) were assessed before and after gaming. Blink rate and interblink interval were measured in situ using an eye tracking headset, before (during conversation) and continuously throughout gaming. Symptoms and tear film changes were examined using paired t-tests. Changes in blinking throughout one hour were examined using repeated measures ANOVA, post-hoc comparisons with Bonferroni correction. Associations examined using Pearson bivariate correlation. Significance level was 0.05. Results Symptoms worsened following one hour smartphone gaming (SANDE + 8.2units, p = 0.01; IOSS + 1.3units, p < 0.001; NRS-average +6.3units, p = 0.03; NRS-comfort +7.6units, p = 0.04; NRS-tiredness +10.1units, p = 0.01), but tear film remained unchanged. Blink rate reduced from 20.8 blinks/min to 8.9 blinks/min (p < 0.001) and interblink interval increased from 2.9 s to 8.7 s (p = 0.002) within the first minute of gaming relative to baseline conversation, and this effect remained unchanged throughout one hour of gaming. Conclusions Smartphone use in children results in dry eye symptoms and immediate and sustained slowing of blinking, with no change in tear function evident up to one hour. Given the ubiquitous use of smartphones by children, future work should examine whether effects reported herein persist or get worse over a longer term causing cumulative damage to the ocular surface.
Collapse
|
22
|
Guillemin C, Hammad G, Read J, Requier F, Charonitis M, Delrue G, Vandeleene N, Lommers E, Maquet P, Collette F. Pupil response speed as a marker of cognitive fatigue in early Multiple Sclerosis. Mult Scler Relat Disord 2022; 65:104001. [DOI: 10.1016/j.msard.2022.104001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2022] [Revised: 06/10/2022] [Accepted: 06/24/2022] [Indexed: 10/17/2022]
|
23
|
Zheng Q, Zhang X, Zhang J, Bai F, Huang S, Pu J, Chen W, Wang L. A texture-aware U-Net for identifying incomplete blinking from eye videography. Biomed Signal Process Control 2022; 75. [DOI: 10.1016/j.bspc.2022.103630] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
24
|
Daley MS, Diaz K, Posada-Quintero HF, Kong Y, Chon K, Bolkhovsky JB. Archetypal physiological responses to prolonged wakefulness. Biomed Signal Process Control 2022. [DOI: 10.1016/j.bspc.2022.103529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
25
|
Zheng Q, Wang L, Wen H, Ren Y, Huang S, Bai F, Li N, Craig JP, Tong L, Chen W. Impact of Incomplete Blinking Analyzed Using a Deep Learning Model With the Keratograph 5M in Dry Eye Disease. Transl Vis Sci Technol 2022; 11:38. [PMID: 35357395 PMCID: PMC8976934 DOI: 10.1167/tvst.11.3.38] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Purpose To establish a deep learning model (DLM) for blink analysis, and investigate whether blink video frame sampling rate influences the accuracy of analysis. Methods This case-controlled study recruited 50 dry eye disease (DED) participants and 50 normal subjects. Blink videos recorded by a Keratograph 5M, symptom questionnaires, and ocular surface assessments were collected. After processing the blink images as datasets, further training and evaluation of DLM was performed. Blink videos of 30 frames per second (FPS) under white light, eight FPS extracted from white light videos, and eight FPS under infrared light were processed by DLM to generate blink profiles, allowing comparison of blink parameters, and their association with DED symptoms and signs. Results The blink parameters based on 30 FPS video presented higher sensitivity and accuracy than those based on eight FPS. The average relative interpalpebral height (IPH), the frequency and proportion of incomplete blinking (IB) were much higher in DED participants than in normal controls (P < 0.001). The IB frequency was closely associated with DED symptoms and signs (|R| ≥ 0.195, P ≤ 0.048), as was IB proportion and the average IPH (R ≥ 0.202, P ≤ 0.042). Conclusions DLM is a powerful tool for analyzing blink videos with high accuracy and sensitivity, and a frame rate ≥ 30 FPS is recommended. The IB frequency is indicative of DED. Translational Relevance The system of DLM-based blink analysis is of great potential for the assessment of IB and diagnosis of DED.
Collapse
Affiliation(s)
- Qinxiang Zheng
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Lei Wang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Han Wen
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Yueping Ren
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Shenghai Huang
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Furong Bai
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Na Li
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| | - Jennifer P Craig
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, Auckland, New Zealand
| | - Louis Tong
- Singapore Eye Research Institute, Singapore; Singapore National Eye Centre, Singapore; Yong Loo Lin School of Medicine, National University of Singapore, Singapore
| | - Wei Chen
- Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China; National Clinical Research Center for Ocular Diseases, Wenzhou, Zhejiang, China
| |
Collapse
|
26
|
Wang J, Bao J, Song W, Li S, Hao Y, Tian L, Jie Y. Assessment of Eyelid Pressure Using a Novel Pressure Measurement Device in Patients With Moderate-to-Severe Dry Eye Disease. Front Med (Lausanne) 2022; 9:833576. [PMID: 35198579 PMCID: PMC8858813 DOI: 10.3389/fmed.2022.833576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 01/17/2022] [Indexed: 11/26/2022] Open
Abstract
Objective To assess a novel eyelid pressure measurement device and study the relationship between eyelid pressure and ocular surface parameters of moderate-to-severe dry eye disease (DED). Methods The present study included 70 eyes of 35 moderate-to-severe DED patients. All subjects were subjected to the following examinations for DED assessment: Ocular Surface Disease Index (OSDI) questionnaire, tear meniscus height (TMH), lipid layer thickness (LLT), number of partial blink (PB), total blink (TB) and partial blink rate (PBR), fluorescein tear breakup time (FBUT), corneal fluorescein staining (CFS), lid margin abnormality, meibum expression assessment (meibum score), meibomian gland dropout (MGd) and Schirmer I test. Pressure of the upper eyelid was measured thrice with the novel pressure measurement device. Repeatability of the device was evaluated by intraclass correlation coefficient (ICC). Safety of the device was evaluated by observing ocular adverse reactions of each subject prior to measurement, at day 1 and day 7 following measurement. Correlations between eyelid pressure and ocular surface parameters of moderate-to-severe DED were analyzed by using Pearson correlation coefficient and Kendall's tau-b correlation coefficient. Results ICC of the measurement results in our study was 0.86. There was no abnormality presenting in all subjects recorded prior to measurement, 1 and 7 days following measurement. The eyelid pressure was significantly correlated with PBR (r = 0.286, P = 0.016), FBUT (r = −0.331, P = 0.005), CFS (r = 0.528, P = 0.000), lid margin abnormality (r = 0.408, P = 0.011) and MGd (r = 0.226, P = 0.016) in moderate-to-severe DED patients, but not significantly correlated with OSDI score (r = 0.016, P = 0.912), TMH (r = −0.002, P = 0.988), meibum score (r = −0.196, P = 0.317), LLT (r = 0.114, P = 0.346), PB (r = 0.116, P = 0.338), TB (r = 0.074, P = 0.544), meibum score (r = −0.196, P = 0.317) and Schirmer I test (r = 0.028, P = 0.821). Conclusion The novel pressure measurement device exhibited good repeatability and safety in measuring eyelid pressure. Significant correlations were noted between the eyelid pressure and PBR, FBUT, CFS, lid margin abnormality and MGd in moderate-to-severe DED. The measurement of eyelid pressure combined with ocular surface parameters may be valuable for the assessment of DED.
Collapse
Affiliation(s)
- Jingyi Wang
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Jiayu Bao
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Wenxiu Song
- Beijing Aier Intech Eye Hospital, Beijing, China
| | - Siyuan Li
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Yiran Hao
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
| | - Lei Tian
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Beijing Advanced Innovation Center for Big Data-Based Precision Medicine, Beihang University and Capital Medical University, Beijing, China
- *Correspondence: Lei Tian
| | - Ying Jie
- Beijing Ophthalmology and Visual Sciences Key Laboratory, Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Ying Jie
| |
Collapse
|
27
|
Huber SE, Martini M, Sachse P. Patterns of eye blinks are modulated by auditory input in humans. Cognition 2021; 221:104982. [PMID: 34923195 DOI: 10.1016/j.cognition.2021.104982] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 11/29/2021] [Accepted: 12/02/2021] [Indexed: 11/16/2022]
Abstract
Previous studies could elaborate a link between attentional processes and eye blinking in both visual and auditory attention tasks. Here we show that this link is active at a fundamental level of perception: presentation of a series of bare sine tones is sufficient to induce a modulation of temporal blink patterns, allowing to determine which series was presented to participants even when they are not required to interactively engage in processing the auditory input. In particular, we monitored eye blinking during an auditory attention task using two series of sine tones, differing in the predictability of the timing of tone onsets. Whereas inter-onset intervals in one tone series corresponded to uncorrelated samples from a normal distribution, they were distributed according to a Gaussian random walk in the other tone series. We find that blink patterns are dynamically modulated by both purely auditory inputs. The magnitude, form, and coherence of the temporal associations between tone onsets and blink events depend strongly on the requirement to respond to the presented stimuli. The predictability of the tone series appears to modulate pre-stimulus blink inhibition given that a response is required. Altogether, these findings suggest eye blink as a readily available, non-invasive behavioral marker for context-sensitive, moment-to-moment allocation of attention.
Collapse
Affiliation(s)
- Stefan E Huber
- Department of Psychology, University of Innsbruck, Innrain 52, 6020 Innsbruck, Austria; Institute for Basic Sciences in Engineering Science, University of Innsbruck, Technikerstraße 13/4, 6020 Innsbruck, Austria.
| | - Markus Martini
- Department of Psychology, University of Innsbruck, Innrain 52, 6020 Innsbruck, Austria
| | - Pierre Sachse
- Department of Psychology, University of Innsbruck, Innrain 52, 6020 Innsbruck, Austria
| |
Collapse
|
28
|
Zhang S, Yan Y, Lu Y, Zhou Y, Fu Y. Effect of Transcutaneous Upper Eyelid Blepharoplasty on Blink Parameters and Lipid Layer Thickness. Front Med (Lausanne) 2021; 8:732041. [PMID: 34881256 PMCID: PMC8645827 DOI: 10.3389/fmed.2021.732041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/01/2021] [Indexed: 11/13/2022] Open
Abstract
Purpose: This study aimed to investigate the effect of transcutaneous upper eyelid blepharoplasty on lipid layer thickness (LLT) and blink parameters in young women during the early postoperative period. Methods: This prospective study included 110 eyes of 55 young female patients (age range, 19–31 years) who underwent transcutaneous upper eyelid blepharoplasty. The LLT and blink parameters measured using a LipiView interferometer were recorded before the surgery and 1 week and 1 month after the surgery. Ocular Surface Disease Index (OSDI) score, noninvasive tear film breakup time (NITBUT), and palpebral fissure height (PFH) measurements were also performed at each time point. Results: The number of blinks significantly decreased (P < 0.001), and the number of partial blinks and partial blink rate (PBR) significantly increased 1 week after the surgery (P = 0.002 and P < 0.001); they all returned to baseline in 1 month. The LLT and OSDI score increased significantly 1 week and 1 month after the surgery (P < 0.001 and P < 0.001). A significant increase in the NITBUT and a significant decrease in the PFH were observed 1 week after the surgery (P < 0.001 and P < 0.001), and the values returned to baseline 1 month after the surgery. No clinical correlation was found between blink parameters and ocular surface parameters. Conclusions: Transcutaneous upper eyelid blepharoplasty led to a change in blink parameters and ocular surface parameters during the early postoperative period. However, this influence was temporary, and the transitory change in blink parameters had no effects on the ocular surface environment.
Collapse
Affiliation(s)
- Siyi Zhang
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yan Yan
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yang Lu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yixiong Zhou
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| | - Yao Fu
- Department of Ophthalmology, Shanghai Ninth People's Hospital, Shanghai JiaoTong University School of Medicine, Shanghai, China.,Shanghai Key Laboratory of Orbital Diseases and Ocular Oncology, Shanghai, China
| |
Collapse
|
29
|
Raposo AC, Lebrilla C, Portela RW, Xu G, Oriá AP. The glycoproteomics of hawk and caiman tears. BMC Vet Res 2021; 17:381. [PMID: 34886864 PMCID: PMC8656020 DOI: 10.1186/s12917-021-03088-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 11/22/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Glycoproteins are important tear components that participate in the stability of the ocular surface. However, the glycopeptides that are present in the tears of wild animals have not yet been described. This work aimed to describe the glycoproteomic profile of roadside hawk (Rupornis magnirostris) and caiman (Caiman latirostris) tears. METHODS Tears collected from 10 hawks and 70 caimans using Schirmer tear test strips were used in this study. The samples were submitted to trypsin digestion and separated using a reverse-phase column coupled to a mass spectrometer associated to a nanospray ionization source. The glycoproteins were categorized as: cellular components, biological processes and molecular function, according to the UniProt Knowledgebase. RESULTS As shown by the liquid chromatography-mass spectrometry, all glycopeptides found were classified as N-type. Of the 51 glycoproteins that were identified in the hawk tear film, the most abundant were ovotransferrin, globulins and complement system proteins. In the caiman tear film, 29 glycoproteins were identified. The most abundant caiman glycoproteins were uncharacterized proteins, ATPases, globulins and proteasome components. Ontological characterization revealed that the glycoproteins were extracellular, and the most identified molecular function was endopeptidase activity for both species. CONCLUSION Glycoproteins are abundant in the tear film of the bird and reptile species studied herein, and all these molecules were shown to have N-type modifications. Location at the extracellular space and an endopeptidase inhibitor activity were the main cell component and molecular function for both species, respectively. These profiles showed differences when compared to human tears, are possibly linked to adaptive processes and can be the basis for further studies on the search of disease biomarkers.
Collapse
Affiliation(s)
- Ana Cláudia Raposo
- School of Veterinary Medicine, Federal University of Bahia, Brazil, Salvador, 40.110-060, Brazil
| | - Carlito Lebrilla
- Chemistry Department, Mass Spectrometry Facilities Campus, University of California, Davis, CA, 95616-8585, USA
| | - Ricardo Wagner Portela
- Institute of Health Sciences, Federal University of Bahia, Brazil, Salvador, 40.110-100, Brazil
| | - Gege Xu
- Chemistry Department, Mass Spectrometry Facilities Campus, University of California, Davis, CA, 95616-8585, USA
| | - Arianne Pontes Oriá
- School of Veterinary Medicine, Federal University of Bahia, Brazil, Salvador, 40.110-060, Brazil.
| |
Collapse
|
30
|
Muntz A, Turnbull PR, Kim AD, Gokul A, Wong D, Tsay TSW, Zhao K, Zhang S, Kingsnorth A, Wolffsohn JS, Craig JP. Extended screen time and dry eye in youth. Cont Lens Anterior Eye 2021; 45:101541. [PMID: 34840070 DOI: 10.1016/j.clae.2021.101541] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 10/18/2021] [Accepted: 11/09/2021] [Indexed: 12/29/2022]
Abstract
PURPOSE Extended screen time amongst youth is a pervasive global phenomenon, with wide-ranging implications for health and quality of life. Dry eye disease is increasingly reported as emerging in paediatric populations and is associated with modified blinking behaviour during extended screen time. This study sought to evaluate spontaneous blink rates, dry eye symptomology and screen use habits of young extended screen time users. METHODS Attendees of a gaming convention in Auckland, NZ, completed a self-directed iPad-based survey on personal screen use habits and ocular symptoms using the 5-item Dry Eye Questionnaire (DEQ-5) and the Symptom Assessment in Dry Eye (SANDE) questionnaire. Blink rate was covertly and concomitantly recorded using the front-facing iPad camera and quantified by automated software. A validated, self-assessment blink test was administered as a proxy for tear film stability measurements. RESULTS A total of 456 respondents (mean age ± SD: 24 ± 10 years, range: 13 - 75, 38% female) reported an average weekly screen time of 43.7 ± 24.4 h. DEQ-5 and SANDE scores were 10 ± 3 and 34 ± 19; 90% of respondents qualified as symptomatic for dry eye disease (DEQ-5 ≥ 6). Blink test results suggested a tear film stability < 10 s in 24% of cases. Poorer symptomology correlated with increased screen use, elevated blink rates and reduced proxy tear film stability (r = 0.15 to 0.22, all p < 0.01). CONCLUSION Extended screen time in a young population was associated with blinking behaviour and symptomology consistent with patients with dry eye. Implementing routine clinical screening, educational interventions, and developing official guidance on safe screen use may help prevent an accelerated degradation of ocular surface health and quality of life in young people.
Collapse
Affiliation(s)
- Alex Muntz
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand.
| | - Philip Rk Turnbull
- School of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Andy D Kim
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Akilesh Gokul
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Daniel Wong
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; School of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Tricia Shau-Wei Tsay
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; School of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Karyn Zhao
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; School of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Simo Zhang
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; School of Optometry and Vision Science, New Zealand National Eye Centre, The University of Auckland, New Zealand
| | - Alec Kingsnorth
- School of Optometry and Vision Science, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - James S Wolffsohn
- School of Optometry and Vision Science, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| | - Jennifer P Craig
- Department of Ophthalmology, New Zealand National Eye Centre, The University of Auckland, New Zealand; School of Optometry and Vision Science, College of Health and Life Sciences, Aston University, Birmingham, United Kingdom
| |
Collapse
|
31
|
Al-Mohtaseb Z, Schachter S, Shen Lee B, Garlich J, Trattler W. The Relationship Between Dry Eye Disease and Digital Screen Use. Clin Ophthalmol 2021; 15:3811-3820. [PMID: 34531649 PMCID: PMC8439964 DOI: 10.2147/opth.s321591] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Accepted: 07/30/2021] [Indexed: 11/23/2022] Open
Abstract
Dry eye disease is characterized by tear film instability that can result in ocular surface damage. Patients with dry eye disease may experience ocular pain/discomfort and visual disturbances that may negatively impact quality of life. Increased use of digital screens for work, communication, and entertainment, especially during times of pandemic, may contribute to dry eye. Extensive cross-sectional studies have shown that digital screen use duration is associated with an increased risk of severe symptoms and clinical diagnosis of dry eye disease in adults. Smartphone use duration has also been found to be greater in school-age children with dry eye disease than in those without dry eye disease. A commonly accepted hypothesis for the relationship between digital screen use and dry eye disease is that digital screen use changes blinking dynamics, leading to ocular dryness. This review describes evidence that digital screen use is associated with dry eye disease, that digital device use alters blinking dynamics, and that dry eye affects mental health and work productivity in digital screen users. Helpful prevention and management strategies for dry eye disease exist for those who use digital screens.
Collapse
Affiliation(s)
- Zaina Al-Mohtaseb
- Department of Ophthalmology, Cullen Eye Institute, Baylor College of Medicine, Houston, TX, USA
| | - Scott Schachter
- Presbyopia and Ocular Surface Disease, Allergan, an AbbVie Company, Irvine, CA, USA
| | | | | | | |
Collapse
|
32
|
Joo T, Joo JH, Park IK, Shin JH. Analysis of Eyelid Blink Characteristics in Patients with Ptosis Using a Smartphone Camera. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2021. [DOI: 10.3341/jkos.2021.62.7.873] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
Purpose: To compare eyelid blink characteristics between patients with ptosis and healthy controls using a smartphone camera. Methods: The ptosis group consisted of 20 senile aponeurotic ptosis patients with margin reflex distance1 ≤2.5 mm and the control group consisted of 10 healthy subjects without ptosis. The ptosis group was further divided into two groups based on an age cutoff of 70 years. Palpebral fissure height, levator function, margin reflex distance1, inter-blink interval, blink duration, blink rate, and blink velocity were measured and compared between the three groups based on photographs of the eyelids and videos of blinking taken with a smartphone camera. Results: The palpebral fissure height, levator function, margin reflex distance1, and blink velocity were lower in the ptosis groups than in the control group but these values did not differ between the two ptosis groups. The palpebral fissure height, levator function, and margin reflex distance1 were correlated with blink velocity. In the receiver operating characteristic (ROC) curve of blink velocity, the area under the receiver operating characteristic (AUROC) curve value was as high as 0.969 and the cut-off value was 32.36 mm/s. Conclusions: It is possible to analyze eyelid blink characteristics using a smartphone camera and the results confirmed that palpebral fissure height, levator function, margin reflex distance1, and blink velocity were lower in the senile aponeurotic ptosis group than in the healthy control group and were unaffected by age. Additionally, blink velocity is valuable for diagnosis of ptosis due to the correlation between the degree of ptosis, blink velocity, and the ROC curve of blink velocity.
Collapse
|
33
|
Diagnostic Performance of a Novel Noninvasive Workup in the Setting of Dry Eye Disease. J Ophthalmol 2020; 2020:5804123. [PMID: 33489333 PMCID: PMC7803097 DOI: 10.1155/2020/5804123] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2020] [Revised: 11/15/2020] [Accepted: 12/01/2020] [Indexed: 11/17/2022] Open
Abstract
Purpose To evaluate the diagnostic performance of a novel noninvasive automated workup employed for the diagnosis of dry eye disease (DED). Methods One hundred patients with mild to moderate DED and 100 matched control subjects were enrolled in this cross-sectional study. Ocular surface examinations were carried out by means of IDRA Plus (SBM Sistemi, Turin, Italy), which allows the automated evaluation of noninvasive breakup time (NIBUT), lipid layer thickness (LLT), tear meniscus height (TMH), infrared meibography for the measurement of meibomian gland loss (MGL), and blinking analysis. Continuous variables were compared between patients with DED and controls by using the Mann–Whitney U test. The area under the curve (AUC) of receiver operating characteristic curves was calculated. The correlations between ocular surface parameters were evaluated with Pearson correlation analysis. Results Patients with DED showed significantly lower values of NIBUT, LLT, and TMH compared to controls (6.9 ± 2.5 vs 10.4 ± 2.4 s, P < 0.001; 64.6 ± 20.3 vs 73.4 ± 21.9 nm, P = 0.003; 0.231 ± 0.115 vs 0.289 ± 0.164, P = 0.012, respectively). Conversely, no significant differences were observed for MGL and blinking analysis (both P > 0.05). NIBUT had the highest diagnostic power (AUC = 0.841, sensitivity = 0.89, and specificity = 0.69), followed by LLT (AUC = 0.621, sensitivity = 0.89, and specificity = 0.55), TMH (AUC = 0.606, sensitivity = 0.57, and specificity = 0.63), blink analysis (AUC = 0.533, sensitivity = 0.48, and specificity = 0.59), and MGL (AUC = 0.531, sensitivity = 0.54, and specificity = 0.48). In patients with DED, NIBUT showed a significant correlation with TMH (R = 0.347, P = 0.002) and blinking analysis (R = 0.356, P < 0.001), while blinking analysis was negatively correlated with MGL (R = −0.315, P = 0.008). Conclusions The automated noninvasive workup validated in this study may be a useful tool for reaching a noninvasive diagnosis of DED with a good performance, especially for NIBUT.
Collapse
|
34
|
Yong PT, Arif N, Sharanjeet-Kaur S, Hairol MI. Double Eyelid Tape Wear Affects Anterior Ocular Health among Young Adult Women with Single Eyelids. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2020; 17:ijerph17217701. [PMID: 33105550 PMCID: PMC7672649 DOI: 10.3390/ijerph17217701] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/29/2020] [Accepted: 10/09/2020] [Indexed: 11/16/2022]
Abstract
Many East Asians apply double eyelid tape to create the double eyelid effect temporarily as a means of increasing their beauty. This study evaluated the effects of four-week wear of double eyelid tape on anterior ocular health in young adult women with single eyelids. Twenty-nine participants who met the inclusion criteria were recruited. The participants’ anterior ocular health was examined including blinking characteristics (blink pattern and blink rate), ocular surface health (presence of corneal abrasion, corneal staining, conjunctival staining, corneal curvatures, meibomian gland dysfunction), tear break up time, intraocular pressure, and subjective comfort level. Participants were required to apply the double eyelid tape for at least eight hours a day and five days a week for four weeks. The parameters were re-measured at the end of each week. There was a significant increase in conjunctival staining, corneal staining, and meibomian gland dysfunction, with a significant reduction in tear break-up time and intraocular pressure. By week 3, all participants had incomplete blinks. There was no significant change in symptoms and subjective comfort level reported. Therefore, patients and eye care practitioners should be aware of the potential implications of double eyelid tape wear on ocular health, with no significant change in subjective comfort.
Collapse
Affiliation(s)
- Pui Theng Yong
- Centre for Community Health Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur 50300, Malaysia; (P.T.Y.); (N.A.)
| | - Norlaili Arif
- Centre for Community Health Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur 50300, Malaysia; (P.T.Y.); (N.A.)
| | - Sharanjeet Sharanjeet-Kaur
- Centre for Rehabilitation & Special Need Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur 50300, Malaysia;
| | - Mohd Izzuddin Hairol
- Centre for Community Health Studies, Faculty of Health Sciences, Universiti Kebangsaan Malaysia, Kuala Lumpur 50300, Malaysia; (P.T.Y.); (N.A.)
- Correspondence:
| |
Collapse
|
35
|
Raposo AC, Lebrilla CB, Portela RW, Goonatilleke E, Neto FAD, Oriá AP. The proteomics of roadside hawk (Rupornis magnirostris), broad-snouted caiman (Caiman latirostris) and loggerhead sea turtle (Caretta caretta) tears. BMC Vet Res 2020; 16:276. [PMID: 32767984 PMCID: PMC7412644 DOI: 10.1186/s12917-020-02495-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2020] [Accepted: 07/27/2020] [Indexed: 12/26/2022] Open
Abstract
Background Tears play an important role in ocular surface protection, and help wild animals maintain visual acuity in the face of air and water friction. The proteomics of tears has only been described for mammals. The knowledge of the proteomics of wild animal tears can aid not only in the setting of normal standards for ocular disease studies in these animals, but also to base the search for new molecules to be used in ophthalmology therapeutics. We therefore set out to describe the proteomic profile of roadside hawk (Rupornis magnirostris), broad-snouted caiman (Caiman latirostris) and loggerhead sea turtle (Caretta caretta) tears. Tears were collected from healthy animals, their spectral profiles were obtained with an LTQ Orbitrap XL mass spectrometer, and the dataset was analyzed against reference taxa. Results For roadside hawk, 446 proteins were identified, the most abundant being albumin, transferrin, globulin and actin. For broad-snouted caiman and loggerhead sea turtle, 1358 and 163 proteins were identified, respectively. Uncharacterized proteins and transferrin were highly abundant in both species. The roadside hawk tear components and their properties were similar to those described for humans, but with a higher albumin concentration. Broad-snouted caiman tears presented a wide diversity of ontological functions, with an abundant presence of enzymatic compounds. In loggerhead sea turtle tears, the predominance of proteins with ion-transport functions was consistent with possible osmolality-maintenance mechanisms. Conclusion These data enhance our understanding of birds and reptiles’ tears microcomposition and may be used to base the discovery of new molecules with high biotechnological potential.
Collapse
Affiliation(s)
- A C Raposo
- School of Veterinary Medicine, Federal University of Bahia, Salvador, 40110-060, Brazil
| | - C B Lebrilla
- Chemistry Department, Mass Spectrometry Facilities Campus, University of California, Davis, CA, 95616-8585, USA
| | - R W Portela
- Institute of Health Sciences, Federal University of Bahia, Salvador, 40110-100, Brazil
| | - E Goonatilleke
- Chemistry Department, Mass Spectrometry Facilities Campus, University of California, Davis, CA, 95616-8585, USA
| | - F A Dórea Neto
- School of Veterinary Medicine, Federal University of Bahia, Salvador, 40110-060, Brazil
| | - A P Oriá
- School of Veterinary Medicine, Federal University of Bahia, Salvador, 40110-060, Brazil.
| |
Collapse
|
36
|
Diagnosis and remediation of blink inefficiency. Cont Lens Anterior Eye 2020; 44:101331. [PMID: 32499135 DOI: 10.1016/j.clae.2020.04.015] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/23/2020] [Accepted: 04/27/2020] [Indexed: 11/23/2022]
Abstract
To examine the role of incomplete blinking in contributing to blink inefficiency, symptoms of dry eye and ocular surface disease. To review methods for diagnosing blink inefficiency (including both reduced overall blink rate and increased incomplete blink rate) and the role of remediation for efficient complete blinking as an essential part of the lacrimal functional unit in maintaining tear homeostasis. Diagnosis and remediation of blink inefficiency appear to have been somewhat misunderstood in the management of dry eye disease. To the extent that a high incomplete blink rate ranks in significance with low blink frequency in contributing to blink inefficiency, measures and remediation of only total blink rate are of reduced usefulness in the diagnosis and treatment of blink inefficiency-related ocular surface exposure, dry eye symptoms and ocular surface disease. In addition, a patient's blink performance during a biomicroscopy or any other clinical assessment of blink efficiency, is unlikely to be characteristic of or relevant to the blink inefficiency that develops and causes symptoms during their various day-to-day activities. There appears to be a strong case for prescribing blink efficiency exercises in the management of many cases of dry eye symptoms and ocular surface disease. Remediation of spontaneous blink inefficiency may require that a motor memory of voluntary complete, rapid, relaxed and natural looking blink formation is established and maintained as the basis for efficient spontaneous blinking. Voluntary forceful blinking may undermine the motor memory of efficient blinking and risk the depletion of any reserves of lipid.
Collapse
|
37
|
Shaafi Kabiri N, Brooks C, Comery T, Kelley ME, Fried P, Bhangu J, Thomas K. The Hawthorne Effect in Eye-blinking: Awareness that One's Blinks are Being Counted Alters Blink Behavior. Curr Eye Res 2020; 45:1380-1384. [PMID: 32272023 DOI: 10.1080/02713683.2020.1752736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Purpose: Spontaneous eye-blink rate is the number of involuntary blinks performed during a certain period of time. Assessing blink rate in humans provides valuable physiological and behavioral data for studying neuropathology and emotional states. Cognitive states, including awareness on the part of the subject that his or her blinks are being counted, may influence blink activity and confound blink rate measurements. The goal of this study was to provide direct experimental evaluation of the hypothesis that subject awareness affects tasked-based blink activity. Materials and methods: 30 young healthy adult males with normal vision underwent a series of tasks - viewing images, talking, sitting quietly, and cross fixation - while being video recorded. Each subject completed the tasks naively, then repeated them after being explicitly told their blink rate was being measured. Blink rate was measured through minute-by-minute blink counts by human raters. Results: We found a transitory impact on blink count during the first and third minute of a passive image-viewing task that occurred immediately after subjects were informed of their eye blinks being counted. However, the overall blink rate across the 7-min passive image-viewing task was not influenced. In three other tasks - fixation, silence, and conversation - we observed no statistically significant difference in minute-by-minute blink count or overall blink rate. Conclusions: We conclude that informing a subject that his eye blinks are being counted exerts a modest but significant acute influence on blinking activity, but critically does not appear to confound blink rate over prolonged tasks.
Collapse
Affiliation(s)
- Nina Shaafi Kabiri
- Department of Anatomy and Neurobiology, Boston University School of Medicine , Boston, Massachusetts, USA
| | - Chris Brooks
- Department of Anatomy and Neurobiology, Boston University School of Medicine , Boston, Massachusetts, USA
| | - Tom Comery
- Early Clinical Development, Pfizer Inc ., Cambridge, Massachusetts, USA
| | | | - Pete Fried
- Department of Anatomy and Neurobiology, Boston University School of Medicine , Boston, Massachusetts, USA
| | - Jaspreet Bhangu
- Department of Anatomy and Neurobiology, Boston University School of Medicine , Boston, Massachusetts, USA
| | - Kevin Thomas
- Department of Anatomy and Neurobiology, Boston University School of Medicine , Boston, Massachusetts, USA
| |
Collapse
|
38
|
McMonnies CW. The clinical and experimental significance of blinking behavior. JOURNAL OF OPTOMETRY 2020; 13:74-80. [PMID: 31992536 PMCID: PMC7182785 DOI: 10.1016/j.optom.2019.09.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2019] [Revised: 09/17/2019] [Accepted: 09/22/2019] [Indexed: 05/23/2023]
Abstract
Evaluations of tear functions frequently involve some form of voluntary control over blink behaviour. To the degree that voluntary control of blinking risks departure from normal-range spontaneous blinking, the tear function findings from such studies may be confounded. Even subject awareness that blinking is being assessed may influence findings if such awareness results in any degree of voluntary control. Ideally, the influence on blink rate and tear functions induced by therapeutic or experimental interventions could be measured against a normal-range baseline spontaneous blink rate in order that any differences found could be validly attributed to those interventions. Sometimes pre-intervention 'rest-related' baseline blink rates have been incorrectly described as 'basal' blink rates without specification of pre-intervention conditions of 'rest' or consideration of any contributions from voluntary control. Also, studies which use only blink rates to measure blink efficiency ignore the critically important contribution of incomplete blinking to blink inefficiency. This review finds that the assessment of normal-range spontaneous blink rates depends on measurement conditions which have frequently been ignored previously. For example, normal-range spontaneous blink rates appear more likely to occur with fixation targets which have a disengaged affect and an associated neutral influence on and from dopamine activity. Ideally, fixation targets should also involve minimal cognitive loading and vision demands. In addition, normal-range (symptom free) spontaneous blink rates are more likely to be assessed in a comfortable ambient environment without subject awareness that blink behaviour is being assessed and when voluntary blinking is not involved.
Collapse
Affiliation(s)
- Charles W McMonnies
- School of Optometry and Vision Science, University of New South Wales, Kensington 2052, Australia.
| |
Collapse
|
39
|
Yazdani M, Elgstøen KBP, Rootwelt H, Shahdadfar A, Utheim ØA, Utheim TP. Tear Metabolomics in Dry Eye Disease: A Review. Int J Mol Sci 2019; 20:E3755. [PMID: 31374809 PMCID: PMC6695908 DOI: 10.3390/ijms20153755] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2019] [Revised: 07/26/2019] [Accepted: 07/30/2019] [Indexed: 12/13/2022] Open
Abstract
Dry eye disease (DED) is a multifactorial syndrome that can be caused by alteration in the quality or quantity of the precorneal tear film. It is considered one of the most common ocular conditions leading patients to seek eye care. The current method for diagnostic evaluations and follow-up examinations of DED is a combination of clinical signs and symptoms determined by clinical tests and questionnaires, respectively. The application of powerful omics technologies has opened new avenues toward analysis of subjects in health and disease. Metabolomics is a new emerging and complementary research discipline to all modern omics in the comprehensive analysis of biological systems. The identification of distinct metabolites and integrated metabolic profiles in patients can potentially inform clinicians at an early stage or during monitoring of disease progression, enhancing diagnosis, prognosis, and the choice of therapy. In ophthalmology, metabolomics has gained considerable attention over the past decade but very limited such studies have been reported on DED. This paper aims to review the application of tear metabolomics in DED.
Collapse
Affiliation(s)
- Mazyar Yazdani
- Department of Medical Biochemistry, Oslo University Hospital, Ullevål, 0450 Oslo, Norway.
- Center for Eye Research, Department of Ophthalmology, Oslo University Hospital, Ullevål, 0450 Oslo, Norway.
- The Norwegian Dry Eye Clinic, 0366 Oslo, Norway.
| | | | - Helge Rootwelt
- Department of Medical Biochemistry, Oslo University Hospital, 0027 Oslo, Norway
| | - Aboulghassem Shahdadfar
- Center for Eye Research, Department of Ophthalmology, Oslo University Hospital, Ullevål, 0450 Oslo, Norway
| | | | - Tor Paaske Utheim
- Department of Medical Biochemistry, Oslo University Hospital, Ullevål, 0450 Oslo, Norway
- The Norwegian Dry Eye Clinic, 0366 Oslo, Norway
- Department of Plastic and Reconstructive Surgery, Oslo University Hospital, 0450 Oslo, Norway
- Department of Maxillofacial Surgery, Oslo University Hospital, 0450 Oslo, Norway
- Department of Ophthalmology, Vestre Viken Hospital Trust, 3019 Drammen, Norway
- Department of Ophthalmology, Stavanger University Hospital, 4011 Stavanger, Norway
- Department of Clinical Medicine, Faculty of Medicine, University of Bergen, 5020 Bergen, Norway
- Department of Ophthalmology, Sørlandet Hospital Arendal, 4604 Arendal, Norway
- Department of Life Sciences and Health, Oslo Metropolitan University, 0130 Oslo, Norway
| |
Collapse
|
40
|
Jie Y, Sella R, Feng J, Gomez ML, Afshari NA. Evaluation of incomplete blinking as a measurement of dry eye disease. Ocul Surf 2019; 17:440-446. [PMID: 31152804 DOI: 10.1016/j.jtos.2019.05.007] [Citation(s) in RCA: 49] [Impact Index Per Article: 8.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2019] [Revised: 05/11/2019] [Accepted: 05/28/2019] [Indexed: 01/27/2023]
Abstract
PURPOSE To investigate the association between partial blinking during spontaneous blinking as measured by interferometry and ocular exams for the assessment of dry eye disease (DED). METHODS This retrospective study included 58 eyes of patients previously diagnosed with DED. Ocular surface assessment included ocular surface disease index (OSDI) score, tear film osmolarity, tear breakup time (TBUT), grading of corneal fluorescein staining, Schirmer I test, and dry eye parameters by the LipiView™ interferometer (TearScience, Morrisville, NC, USA), including lipid layer thickness of the tear film (LLT), meibomian gland dropout (MGd), number of incomplete and complete blinks per 20 s and the partial blinking rate (PBR). Generalized estimation equations (GEE) were used for association testing between each variable of interest. The working correlation for each GEE model was selected using the Corrected Quasi-likelihood under the Independence Model Criterion. RESULTS The number of incomplete blinks was significantly associated with TBUT (P = 0.006), OSDI (P = 0.000) and MGd (P = 0.000). PBR was significantly associated with OSDI (P = 0.032) and MGd (P = 0.000). The number of complete blinks was significantly associated with TBUT (P = 0.032), but not with other ocular surface parameters. MGd was significantly associated with TBUT (P = 0.002) and OSDI (P = 0.001). LLT was significantly associated with tear film osmolarity (P = 0.007), and tear film osmolarity was significantly associated with LLT (P = 0.000). CONCLUSIONS Incomplete blinking is associated with decreased TBUT, increased OSDI, and increased MGd possibly through its contribution to meibomian gland obstruction and subsequent loss of tear film homeostasis. It may, therefore, be considered an additive measure for mild-to-moderate DED assessment.
Collapse
Affiliation(s)
- Ying Jie
- Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, USA; Beijing Tongren Dry Eye Center, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, China
| | - Ruti Sella
- Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, USA
| | - Jun Feng
- Beijing Tongren Dry Eye Center, Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, China
| | - Maria L Gomez
- Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, USA
| | - Natalie A Afshari
- Shiley Eye Institute, Department of Ophthalmology, University of California San Diego, La Jolla, CA, USA.
| |
Collapse
|
41
|
Koh S. Irregular Astigmatism and Higher-Order Aberrations in Eyes With Dry Eye Disease. Invest Ophthalmol Vis Sci 2019; 59:DES36-DES40. [PMID: 30481804 DOI: 10.1167/iovs.17-23500] [Citation(s) in RCA: 38] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Visual disturbances were included in the definition of dry eye disease in the 2007 Dry Eye Workshop report. As a result, quality of vision (QoV) in dry eye patients has received increased attention. Corneal topography and wavefront sensors have been used to objectively and quantitatively evaluate optical quality, with data showing increases in irregular astigmatism and higher-order aberrations (HOAs) in dry eye patients. Furthermore, ocular optical characteristics are influenced by the tear film, which constantly fluctuates over time. Therefore, dynamic quantitative assessments of optical quality with continuous measurements are essential to understanding QoV in dry eye patients. This review summarizes what is known and what advances have been made in evaluating and understanding QoV in dry eye patients. In particular, corneal topographic and wavefront analyses, conducted both overseas and in Japan, are described.
Collapse
Affiliation(s)
- Shizuka Koh
- Department of Innovative Visual Science, Osaka University Graduate School of Medicine, Osaka, Japan.,Department of Ophthalmology, Osaka University Graduate School of Medicine, Osaka, Japan
| |
Collapse
|
42
|
Mork R, Falkenberg HK, Fostervold KI, Thorud HMS. Visual and psychological stress during computer work in healthy, young females-physiological responses. Int Arch Occup Environ Health 2018; 91:811-830. [PMID: 29850947 PMCID: PMC6132651 DOI: 10.1007/s00420-018-1324-5] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2017] [Accepted: 05/22/2018] [Indexed: 11/26/2022]
Abstract
Purpose Among computer workers, visual complaints, and neck pain are highly prevalent. This study explores how occupational simulated stressors during computer work, like glare and psychosocial stress, affect physiological responses in young females with normal vision. Methods The study was a within-subject laboratory experiment with a counterbalanced, repeated design. Forty-three females performed four 10-min computer-work sessions with different stress exposures: (1) minimal stress; (2) visual stress (direct glare); (3) psychological stress; and (4) combined visual and psychological stress. Muscle activity and muscle blood flow in trapezius, muscle blood flow in orbicularis oculi, heart rate, blood pressure, blink rate and postural angles were continuously recorded. Immediately after each computer-work session, fixation disparity was measured and a questionnaire regarding perceived workstation lighting and stress was completed. Results Exposure to direct glare resulted in increased trapezius muscle blood flow, increased blink rate, and forward bending of the head. Psychological stress induced a transient increase in trapezius muscle activity and a more forward-bent posture. Bending forward towards the computer screen was correlated with higher productivity (reading speed), indicating a concentration or stress response. Forward bent posture was also associated with changes in fixation disparity. Furthermore, during computer work per se, trapezius muscle activity and blood flow, orbicularis oculi muscle blood flow, and heart rate were increased compared to rest. Conclusions Exposure to glare and psychological stress during computer work were shown to influence the trapezius muscle, posture, and blink rate in young, healthy females with normal binocular vision, but in different ways. Accordingly, both visual and psychological factors must be taken into account when optimizing computer workstations to reduce physiological responses that may cause excessive eyestrain and musculoskeletal load.
Collapse
Affiliation(s)
- Randi Mork
- Department of Public Health Science, Norwegian University of Life Sciences, Ås, Norway.
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, National Centre for Optics, Vision and Eye Care, P.O. Box 235, 3603, Kongsberg, Norway.
| | - Helle K Falkenberg
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, National Centre for Optics, Vision and Eye Care, P.O. Box 235, 3603, Kongsberg, Norway
| | | | - Hanne Mari S Thorud
- Department of Optometry, Radiography and Lighting Design, University of South-Eastern Norway, National Centre for Optics, Vision and Eye Care, P.O. Box 235, 3603, Kongsberg, Norway
| |
Collapse
|