1
|
Yang D, Chen Z, Zhao W, Zhao J, Zhou X, Wang J. Characterization the corneal transparency profile in SMILE-treated myopic patients with densitometry: A 7-year cohort study. Indian J Ophthalmol 2024; 72:S429-S434. [PMID: 38317330 DOI: 10.4103/ijo.ijo_1787_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2023] [Accepted: 11/03/2023] [Indexed: 02/07/2024] Open
Abstract
PURPOSE To investigate 7-year changes in corneal densitometry (CD) and its influencing factors following small incision lenticule extraction (SMILE) for moderate to high myopia. METHODS A total of 32 patients (52 eyes) with a mean spherical equivalent (SE) refraction of -6.30 ± 1.30 D who underwent SMILE were recruited for this prospective study. Pre- and postoperative CD and corneal aberrations were measured by an oculus Pentacam system, and patients were followed up to 7 years. The CD evolution over time and its influencing factors were explored. RESULTS No complications were observed after SMILE. There was a significant time effect on postoperative CD ( P < 0.05). The CD values at the 0-to-2 and 2-to-6 mm of the anterior layer increased at the first day ( P < 0.05) and declined to baselines at 1 year postoperatively; after that, CD values at any zone and any corneal layer presented a decreasing trend over time (all P < 0.05). Multivariate analysis showed that postoperative CD was positively correlated with age and optical zone (OZ), whereas negatively correlated with SE, corrected distance visual acuity (CDVA), and corneal aberrations (higher-order aberrations, Coma0 and Coma90) (all P < 0.05). Generalized estimating equation revealed that age, SE, CDVA, OZ, and Coma0 were the main factors influencing postoperative CD values (all P < 0.05). CONCLUSION CD manifested a long-term decreasing trend in moderate to high myopia treated with SMILE. Its main influencing factors are age, SE, CDVA, OZ, and Coma0.
Collapse
Affiliation(s)
- Dongmei Yang
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Second People's Hospital of Yunnan Province, Affiliated Hospital of Yunnan University, Kunming, China
| | - Zhuoyi Chen
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Wuxiao Zhao
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Center for Optometry and Visual Science, The People's Hospital of Guangxi Zhuang Autonomous Region, Guangxi Academy of Medical Sciences, Nanning, China
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jifang Wang
- Eye Institute and Department of Ophthalmology, Fudan University, Shanghai, China
- Department of Nursing, Eye and ENT Hospital, Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
2
|
Foo VHX, Liu YC, Ang M, Htoon HM, Ting DSJ, Mehta JS. Comparative Study of Primary SMILE, SMILE Enhancement, and Femtosecond Laser-Assisted LASIK on Higher Order Aberrations and Corneal Densitometry. J Refract Surg 2024; 40:e291-e303. [PMID: 38717083 DOI: 10.3928/1081597x-20240314-01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/20/2024]
Abstract
PURPOSE To compare differences in corneal densitometry (CD) and higher order aberrations (HOAs) in eyes that underwent small incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for the treatment of myopia and myopic astigmatism at postoperative months 3, 6, and 12, and to evaluate their changes in a separate cohort of eyes after SMILE enhancement. METHODS In this prospective, randomized, paired-eye clinical trial, consecutive eligible participants were randomized to undergo SMILE or FS-LASIK in either eye. Main outcome measures were CD and HOAs preoperatively and at 3, 6, and 12 months postoperatively. A separate cohort of consecutive patients who had SMILE and underwent enhancement were also included for comparison. RESULTS For CD, no significant differences were found between SMILE and FS-LASIK up to month 12. For HOA measured by wavefront aberrometry, both SMILE and FS-LASIK had an increase in total root mean square (RMS) HOAs, spherical aberration (SA), and vertical coma up to month 12. SMILE had an additional increase in vertical quatrefoil, and FS-LASIK had an increase in horizontal coma at month 12. FS-LASIK had higher SA than SMILE, whereas SMILE had higher vertical quatrefoil than FS-LASIK at month 12. Central and posterior zone CD had significantly decreased after SMILE enhancement compared to after primary SMILE up to 2 years after enhancement. RMS HOAs, lower order aberrations, and SA were all increased after SMILE enhancement compared to after primary SMILE. CONCLUSIONS SMILE induced lower SA but higher vertical quatrefoil than FS-LASIK at 1 year. Both SMILE and FS-LASIK had similar increases in RMS HOAs and vertical coma up to 1 year. There were no differences in CD between both groups. SMILE enhancement additionally had decreased central and posterior CD but greater RMS HOAs and SA compared to primary SMILE. [J Refract Surg. 2024;40(5):e291-e303.].
Collapse
|
3
|
Lin F, Cheng C, Li M, Liu S, Zhou X. Visual outcomes and corneal densitometry after allogenic and autologous lenticule intrastromal keratoplasty for the correction of moderate-to-high hyperopia. Graefes Arch Clin Exp Ophthalmol 2023; 261:3015-3022. [PMID: 37199799 DOI: 10.1007/s00417-023-06097-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Revised: 04/17/2023] [Accepted: 04/26/2023] [Indexed: 05/19/2023] Open
Abstract
AIM This study aimed to evaluate the visual outcomes and corneal densitometry (CD) after allogenic lenticule intrastromal keratoplasty (AL-LIKE) and autologous lenticule intrastromal keratoplasty (AU-LIKE) for the correction of moderate-to-high hyperopia. METHODS Ten subjects (14 eyes) underwent AL-LIKE and eight (8 eyes) underwent AU-LIKE. Patients were examined preoperatively and 1 day, 1 month, and 6 months postoperatively. The visual outcomes and CD for both surgical methods were evaluated. RESULTS No postoperative complications were observed with either method. The efficacy index was 0.85±0.18 and 0.90±0.33 in the AL-LIKE and AU-LIKE groups, respectively. The safety indices were 1.07±0.21 and 1.25±0.37 in the AL-LIKE and AU-LIKE groups, respectively. The CD values of the anterior, central, and posterior layers in the AL-LIKE group increased significantly at 1 day postoperatively (all P < 0.05). The CD values of the anterior and central layers remained significantly higher than the preoperative values at 6 months postoperatively (all P < 0.05). The CD values of the anterior layer in the AU-LIKE group increased significantly 1 day postoperatively (all P < 0.05) and decreased to preoperative values (all P > 0.05) 1 month postoperatively. CONCLUSION Both AL-LIKE and AU-LIKE exhibit good efficacy and safety in correcting hyperopia. However, AU-LIKE may have a smaller affected area and faster recovery time than those associated with AU-LIKE related to changes in corneal transparency.
Collapse
Affiliation(s)
- Feng Lin
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Chiwen Cheng
- Affiliated Eye Hospital of Nanchang University, Nanchang, 330006, China
| | - Meiyan Li
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China
| | - Shengtao Liu
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China.
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.
- NHC Key Laboratory of Myopia (Fudan University), Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai, 200031, China.
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, 200031, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai, 200031, China.
| |
Collapse
|
4
|
Han T, Zhang L, Huang Y, Shen Y, Zhou X, Xu Y. Seven-year corneal densitometry changes after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis. Lasers Med Sci 2023; 38:183. [PMID: 37572159 DOI: 10.1007/s10103-023-03850-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 08/05/2023] [Indexed: 08/14/2023]
Abstract
This study aims to investigate the 7-year changes in corneal densitometry (CD) after small incision lenticule extraction (SMILE) and femtosecond laser-assisted in situ keratomileusis (FS-LASIK). Forty-two eyes undergoing SMILE and thirty-one undergoing FS-LASIK were included in this retrospective study. CD was measured preoperatively and at 3 and 7 years postoperatively. Three concentric radial zones (0-2, 2-6, and 6-10 mm) of three different corneal depths (anterior 120 μm, posterior 60 μm, and central layer) were analyzed. In all three zones of the three corneal layers, no significant difference in CD was found between the two groups preoperatively and at 3 and 7 years postoperatively (all P > 0.05). All CD values in the three zones of the anterior and central layers significantly declined at 3 years postoperatively (all P < 0.001), and then increased at 7 years postoperatively compared to corresponding 3-year values (all P < 0.01). In the posterior layer, CD values in the 0-2-mm and 2-6-mm zones decreased at 3 years postoperatively (all P < 0.01) and continued to decrease at 7 years postoperatively (all P < 0.01). Similar CD trends were observed after SMILE and FS-LASIK. Posterior layer CD showed a decrease throughout the study period. In the anterior and central layers, CD values decreased and then increased at 7 years postoperatively. The transparency changes might have been due to age-related three-dimensional growth of collagen fibers and wound-healing reactions.
Collapse
Affiliation(s)
- Tian Han
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Luoli Zhang
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yangyi Huang
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Yang Shen
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China
| | - Xingtao Zhou
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China.
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China.
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China.
| | - Ye Xu
- Department of Ophthalmology, Eye and ENT Hospital of Fudan University, Shanghai, China.
- NHC Key Laboratory of Myopia (Fudan University), Shanghai, China.
- Research Center of Ophthalmology and Optometry Shanghai, Shanghai, China.
- Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care (20DZ2255000), Shanghai, China.
| |
Collapse
|
5
|
He Y, Ma BS, Zeng JH, Ma DJ. Corneal optical density: Structural basis, measurements, influencing factors, and roles in refractive surgery. Front Bioeng Biotechnol 2023; 11:1144455. [PMID: 37091331 PMCID: PMC10117965 DOI: 10.3389/fbioe.2023.1144455] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Accepted: 03/29/2023] [Indexed: 04/08/2023] Open
Abstract
The cornea is the main refractive medium of the human eye, and its clarity is critical to visual acuity. Corneal optical density (COD) is an important index to describe corneal transparency. Intact corneal epithelial and endothelial cells, regular arrangement of collagen fibers in the stroma, and normal substance metabolism are all integral for the cornea to maintain its transparency. In the last two decades, the Pentacam Scheimpflug imaging system has emerged as a breakthrough for the measurement of COD (also called corneal densitometry). It has been found that a wide variety of factors such as age, refractive status, and corneal diseases can affect COD. Different corneal refractive surgery methods also change COD in different corneal regions and layers and affect visual acuity following the surgery. Thus, COD has gradually become a significant indicator to evaluate corneal health, one on which the attention of clinicians has been increasingly focused.
Collapse
Affiliation(s)
- Ye He
- Changsha Aier Eye Hospital, Changsha, China
| | - Bo-Sheng Ma
- Department of Ophthalmology, The Second Xiangya Hospital, Central South University, Changsha, China
| | - Jun-Hao Zeng
- Xiangya School of Medicine, Central South University, Changsha, China
| | - Dai-Jin Ma
- Changsha Aier Eye Hospital, Changsha, China
- *Correspondence: Dai-Jin Ma,
| |
Collapse
|
6
|
Comparison of Corneal Densitometry and Visual Quality after Small Incision Lenticule Extraction (SMILE) and Laser Epithelial Keratomileusis (LASEK): One-Year Comparative Study. BIOMED RESEARCH INTERNATIONAL 2023; 2023:3430742. [PMID: 36778055 PMCID: PMC9911227 DOI: 10.1155/2023/3430742] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Revised: 12/22/2022] [Accepted: 01/16/2023] [Indexed: 02/05/2023]
Abstract
Purpose To investigate changes in corneal densitometry (CD) and visual quality following small incision lenticule extraction (SMILE) and laser epithelial keratomileusis (LASEK) in patients with mild-to-moderate myopia. Methods A retrospective analysis was performed on 24 and 25 patients (46 eyes each) who underwent SMILE and LASEK, respectively, for mild-to-moderate myopia. The visual quality and CD values were recorded. Using the Pentacam Scheimpflug system, CD values were collected in three concentric optical zones at the depths of the anterior, central, and posterior layers. Efficacy, safety, predictability, corneal wavefront aberrations, and QoV scores were measured to evaluate visual quality. A correlation analysis was performed between changes in CD and clinical characteristics. Results There were no statistical differences in efficacy and safety indices between the two groups. At 3 months postoperatively, a pronounced reduction in several zones was observed in the LASEK group (p < 0.05), whereas no obvious change was observed in the SMILE group. There were obvious changes in the CD values in several zones in the SMILE and LASEK groups (p < 0.05) after 1 year. The magnitude of the CD changes in the anterior and central corneal layers was smaller in the SMILE group than in the LASEK group (all p < 0.05). Lower HOAs, spherical aberration, and horizontal comas of the anterior and whole corneal surfaces were observed in the SMILE group. QoV scores were similar between the two groups. Conclusion CD decreased in the SMILE and LASEK groups after 1 year; there was a smaller reduction in SMILE than in LASEK. SMILE and LASEK did not differ significantly in terms of safety and effectiveness in correcting mild-to-moderate myopia.
Collapse
|
7
|
In vivo confocal microscopy of sub-basal corneal nerves and corneal densitometry after three kinds of refractive procedures for high myopia. Int Ophthalmol 2022; 43:925-935. [PMID: 36153757 DOI: 10.1007/s10792-022-02494-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2021] [Accepted: 08/20/2022] [Indexed: 10/14/2022]
Abstract
PURPOSE To observe corneal nerve fibers and densitometry after small incision lenticule extraction (SMILE), femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) and laser-assisted subepithelial keratomileusis (LASEK) for high myopia. METHODS This is a prospective, cross-sectional research study. Patients with high myopia (equivalent spherical lens: -6.00 and -11.00D) who underwent laser corneal refractive surgery were divided into three groups: SMILE, FS-LASIK and LASEK. Scheimpflug imaging of corneal nerves in five areas was observed by confocal microscopy before and 6, 12 months after surgery. Corneal densitometry was measured by Pentacam anterior segment analysis system. RESULTS Overall, 59 patients were enrolled. The nerve density in the central area did not recover to the preoperative level in three groups until 12 months. The density and length of corneal nerves in central and lower area were better in the SMILE group 6 months postoperatively (p = 0.01), while nerve density did not differ significantly among three groups 12 months postoperatively (p = 0.18). Nerve fibers in central and temporal region were wider in LASEK than that in other two groups at 6- and 12-month follow-up. Corneal densitometry in the central 6 mm diameter was significantly higher in the LASEK group compared with other two groups 6 months postoperatively (p = 0.04). Twelve months postoperatively, corneal densitometry in range of all zone was lower in SMILE than in FS-LASIK and LASEK (p = 0.01, 0.03, 0.04). CONCLUSIONS Compared with FS-LASIK and LASEK, SMILE-treated eyes with high myopia had certain advantages in nerve density, length and nerve connection way and had better corneal transparency after operation.
Collapse
|
8
|
Xu C, Yang D, Zhao W, Long Z, Zhang Z, Shen Y, Zhou X, Zhao J. Long-term changes in corneal densitometry and associated factors following small incision lenticule extraction for moderate and high myopia. Front Med (Lausanne) 2022; 9:945894. [PMID: 36160150 PMCID: PMC9492929 DOI: 10.3389/fmed.2022.945894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Accepted: 08/15/2022] [Indexed: 11/28/2022] Open
Abstract
Purpose To investigate long-term trends in corneal densitometry and associated influencing factors following small incision lenticule extraction (SMILE). Methods A comparative study was performed among 72 eyes of 38 patients undergoing SMILE. Eyes were divided into moderate myopia [mean spherical equivalent (SE),−4.22 ± 0.68D] and high myopia (mean SE,−7.63 ± 1.09 D) groups. Visual acuity, manifest refraction, corneal topography and corneal densitometry (CD) were evaluated preoperatively and 3 years postoperatively. Results The efficacy indices at last postoperative follow-up (42.47 ± 0.51 months) were 0.92 ± 0.21 and 0.97 ± 0.22, the safety indices were 1.12 ± 0.17 and 1.14 ± 0.21 for high and moderate myopia, respectively (all P > 0.05). CD values in the 0–6 mm zone of the posterior corneal layer was statistically significantly lower than the preoperative values in both groups. Postoperative CD values (0–2 mm zone) in the posterior layer of the high myopia group were statistically significantly lower than in the moderate myopia group (P = 0.025); CD values (2–6 mm zone) in the anterior layer were higher in the high myopia group (P = 0.026). Correlation analyses showed that CD values in the 0–2 mm middle layer were negatively correlated with lenticule thickness in high myopia (r = −0.411, P = 0.016); there was a negative correlation between the CD values (0–6 mm) and corneal oblique trefoil in this group (P < 0.05). Conclusion Corneal transparency in the 0–6 mm zone of the posterior cornea increased following SMILE in moderate and high myopia. Long-term CD values in high myopia may be correlated with oblique trefoil and lenticule thickness.
Collapse
Affiliation(s)
- Changqin Xu
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Department of Ophthalmology, The Third People's Hospital of Chengdu, The Affiliated Hospital of Southwest Jiaotong University, Chengdu, China
| | - Dongmei Yang
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Wuxiao Zhao
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Zhigang Long
- Department of Ophthalmology, Liuzhou Red Cross Hospital, Liuzhou, China
| | - Zhe Zhang
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yang Shen
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Xingtao Zhou
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- *Correspondence: Xingtao Zhou
| | - Jing Zhao
- Eye Institute and Department of Ophthalmology, Eye and ENT Hospital, Fudan University, Shanghai, China
- Key Laboratory of Myopia, NHC Key Laboratory of Myopia (Fudan University), Chinese Academy of Medical Sciences, Shanghai, China
- Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
- Jing Zhao
| |
Collapse
|
9
|
Hou J, Wang Y, Zhang J, Lei Y, Ma Z, Zhang Y, Zheng X. Corneal densitometry after allogeneic small-incision intrastromal lenticule implantation for hyperopia correction. BMC Ophthalmol 2022; 22:286. [PMID: 35764952 PMCID: PMC9241174 DOI: 10.1186/s12886-022-02454-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 05/11/2022] [Indexed: 11/12/2022] Open
Abstract
Purpose To evaluate corneal densitometry after allogeneic corneal small-incision intrastromal lenticule implantation (SILI) for hyperopia. Methods A retrospective study. Thirty-one hyperopic eyes of 24 patients who underwent SILI were enrolled in this study. Examinations took place preoperatively and 1 week, 1 month, 3 months, and 6 months postoperatively. Corneal densitometry (CD) from different concentric radial zones (0–2, 2–6, and 6–10 mm annulus) and layers (anterior, central, and posterior) were obtained using Scheimpflug imaging. The association between CD changes and the uncorrected distance visual acuity (UDVA), spherical equivalent (SE), central corneal thickness (CCT) and K value were examined. Results No serious intraoperative complications occurred during SILI. The mean total CD increased postoperatively compared to preoperatively (P < 0.01). However, no significant differences were found among the four subsequent follow-up time points (P > 0.05). At 6 months postoperatively, the CD values showed an increase of 2.71 ± 2.52, 2.23 ± 2.25, and 1.87 ± 2.46 at the 0–2, 2–6, and 6–10 mm annuli, respectively (all at P < 0.01). The anterior 120 μm displayed the highest densitometry before and after surgery (all at P < 0.01). No significant increase was found within the posterior 60 μm of the cornea (P > 0.05). No correlation was found between the CD and relevant parameters(all at P > 0.05). Conclusions SILI resulted in an increase in CD within the surgically altered area, however such change has no significant correlation with visual outcomes.
Collapse
Affiliation(s)
- Jie Hou
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China
| | - Yan Wang
- Tianjin Key Laboratory of Ophthalmology and Visual Science, Tianjin Eye Hospital, Clinical College of Ophthalmology, Tianjin Medical University, Tianjin, China
| | - Jing Zhang
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China
| | - Yulin Lei
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China.
| | - Zhixing Ma
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China
| | - Ying Zhang
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China
| | - Xiuyun Zheng
- Jinan Mingshui Eye Hospital, Number 5601, Longquan Road, Zhangqiu District, 250200, Jinan, China
| |
Collapse
|
10
|
Zhao L, Jing L, Li J, Du X. Changes in corneal densitometry after long-term orthokeratology for myopia and short-term discontinuation. PLoS One 2022; 17:e0263121. [PMID: 35120161 PMCID: PMC8815901 DOI: 10.1371/journal.pone.0263121] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 01/12/2022] [Indexed: 11/18/2022] Open
Abstract
Purpose
To quantify changes in corneal densitometry after long-term orthokeratology treatment in myopic children and to analyze the reversibility one month after discontinuation.
Methods
Seventy-four myopic subjects aged 8–16 years, who wore orthokeratology lenses for two years, were divided into relatively steep- (lens movement within 1.0–1.5 mm, thirty-six participants) and flat-fitting groups (lens movement within 1.5–2.0 mm, thirty-eight participants). Based on refractive errors, they were divided into low and moderate myopia groups (thirty-seven participants in each group). Corneal densitometry was performed using Pentacam (Oculus Optikgeräte GmbH, Wetzlar, Germany) at each follow-up timepoint. Repeated-measures analysis of variance was used to compare the parameters before and after orthokeratology.
Results
The corneal densitometry values over the 0–10 mm diameter area increased from 12.84±1.38 grayscale units (GSU) at baseline to 13.59±1.42 GSU after three-month orthokeratology (P = .001) and reached 14.92±1.45 GSU at two years (P < .001). An increase in densitometry began at one month (P = .001) over the 0–2 mm annulus compared with that at three months over the 2–6 mm and 6–10 mm zones (P = .002,.014). The densitometry values significantly increased at three months in the relatively steep-fitting group (P = .003) and at one year in the relatively flat-fitting group (P = .001). After discontinuation of orthokeratology for one month, the values showed no significant decrease.
Conclusions
Long-term orthokeratology treatment causes a small but statistically significant increase in corneal densitometry values. During the first year, the onset of these changes was related to the fitting mode. Corneal densitometry values showed no significant reduction after one-month discontinuation.
Collapse
Affiliation(s)
- Lianghui Zhao
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
- Weifang Medical University, Weifang, China
| | - Lili Jing
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
| | - Jie Li
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
| | - Xianli Du
- Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China
- State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Shandong Eye Institute, Shandong First Medical University & Shandong Academy of Medical Sciences, Qingdao, China
- * E-mail:
| |
Collapse
|
11
|
Corneal Light Scatter After Ultrathin Descemet Stripping Automated Endothelial Keratoplasty Versus Descemet Membrane Endothelial Keratoplasty in Descemet Endothelial Thickness Comparison Trial: A Randomized Controlled Trial. Cornea 2021; 39:691-696. [PMID: 31939923 DOI: 10.1097/ico.0000000000002256] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE To compare the degree of corneal light scatter as measured by densitometry in ultrathin Descemet Stripping Automated Endothelial Keratoplasty (UT-DSAEK) and Descemet Membrane Endothelial Keratoplasty (DMEK) in the Descemet endothelial thickness comparison trial. METHODS This was a prespecified secondary analysis of the Descemet endothelial thickness comparison trial, which was a prospective, randomized controlled trial. Subjects with isolated endothelial dysfunction were enrolled and were randomized to either UT-DSAEK or DMEK. Corneal opacity was quantitatively measured by Pentacam densitometry (OCULUS) at 3, 6, and 12 months. RESULTS Fifty eyes of 38 patients were enrolled at the Casey Eye Institute at Oregon Health & Science University and the Byers Eye Institute at Stanford University. Corneal densitometry for the anterior and posterior layers improved in both UT-DSAEK and DMEK after surgery. The decrease was more pronounced in the posterior layer for both groups. However, there was no difference in the degree of corneal light scatter between UT-DSAEK and DMEK at postoperative month 12, and no difference in change in densitometry was observed between the 2 arms from baseline to month 12. CONCLUSIONS Both UT-DSAEK and DMEK experience an improvement in the degree of corneal light scatter after surgery. However, there was no difference in densitometry between the 2 groups at month 12. Therefore, other factors such as higher order aberrations in the posterior cornea rather than stromal-stromal interface haze mediate the superior visual outcomes in DMEK compared with UT-DSAEK.
Collapse
|
12
|
Wei R, Li M, Yang W, Shen Y, Zhao Y, Fu D, Shang J, Zhang J, Choi J, Zhou X. Corneal Densitometry After Small Incision Lenticule Extraction (SMILE) and Femtosecond Laser-Assisted LASIK (FS-LASIK): 5-Year Prospective Comparative Study. Front Med (Lausanne) 2020; 7:521078. [PMID: 33240901 PMCID: PMC7681246 DOI: 10.3389/fmed.2020.521078] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Accepted: 10/05/2020] [Indexed: 11/13/2022] Open
Abstract
Purpose: To investigate long-term changes in corneal densitometry (CD) following small incision lenticule extraction (SMILE) vs. femtosecond laser-assisted LASIK (FS-LASIK) in patients with myopia or myopic astigmatism. Methods: Prospective analysis was performed in 66 eyes of 38 patients (13 males) who underwent SMILE and 54 eyes of 29 patients (5 males) who underwent FS-LASIK. In all patients, an ocular examination was performed preoperatively, and at 6–12 months and 5 years postoperatively. CD was obtained with the Pentacam Scheimpflug imaging system at the 0–2-mm, 2–6-mm, and 6–10-mm zones of the cornea at depth of anterior 120 μm, midcornea, and posterior 60 μm. Correlation analysis was performed between postoperative change in CD and other variables such as age, type of surgery, central corneal thickness, spherical equivalent, lenticule thickness/ablation depth, and changes in wavefront aberrations. Results: At postoperative 6–12 months, a significant reduction at several corneal zones in the FS-LASIK cohort (P < 0.05) was observed. In the SMILE cohort, no significant change in CD relative to baseline was observed. However, at 5 years postoperatively, in both groups, a significant decrease in CD was observed in three zones of three layers (all P < 0.001). The change in CD was similar between groups at postoperative 6–12 months, but at 5 years the magnitude of change was significantly smaller in SMILE than FS-LASIK in the anterior and central layers (all P < 0.05). Conclusion: CD with the Scheimpflug imaging system showed a significant decrease at 5 years after SMILE or FS-LASIK, and the change was significantly less pronounced after SMILE.
Collapse
Affiliation(s)
- Ruoyan Wei
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Meiyan Li
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Weiming Yang
- Department of Ophthalmology, Children's Hospital of Fudan University, Shanghai, China
| | - Yang Shen
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Yu Zhao
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Dan Fu
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jianmin Shang
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| | - Jing Zhang
- Department of Epidemiology and Biostatistics, School of Public Health, Fudan University, Shanghai, China
| | - Joanne Choi
- Department of Ophthalmology, Kresge Eye Institute, Wayne State University, Detroit, MI, United States
| | - Xingtao Zhou
- Department of Ophthalmology and Optometry, Eye and ENT Hospital, Fudan University, Shanghai, China.,NHC Key Laboratory of Myopia, Fudan University, Shanghai, China.,Shanghai Research Center of Ophthalmology and Optometry, Shanghai, China
| |
Collapse
|
13
|
Alio Del Barrio JL, Parafita-Fernandez A, Canto-Cerdan M, Alio JL, Teus M. Evolution of corneal thickness and optical density after laser in situ keratomileusis versus small incision lenticule extraction for myopia correction. Br J Ophthalmol 2020; 105:1656-1660. [PMID: 32980816 DOI: 10.1136/bjophthalmol-2020-316601] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2020] [Revised: 06/19/2020] [Accepted: 09/06/2020] [Indexed: 11/04/2022]
Abstract
PURPOSE To compare the thickness and stromal optical density (OD) evolution of the flap and cap after femtosecond (FS-LASIK; Visumax) and small incision lenticule extraction (SMILE), respectively, for myopia correction. METHODS A prospective study comprising 78 eyes (n=39 per group) was performed. Anterior segment optical coherence tomography (MS39) images were collected at each postoperative visit (1 day, 1 week and 1 and 3 months) and flap/cap thicknesses were measured. Using ImageJ software, three regions were defined to measure OD (in grayscale units: flap/cap stroma, residual stromal bed (RSB) and all stroma (including flap/cap-stroma, surgical interface and RSB). RESULTS Mean central thickness significantly increased during the 3-month follow-up in both LASIK (5.43±4.23 μm; p=0.0118) and SMILE (2.76±5.61 μm; p=0.0118), with differences between both techniques statistically significant (p=0.020). All OD values showed a statistically significant reduction during SMILE follow-up: cap 48.96±5.55 versus 44.95±5.41 (p=0.19×10-6), RSB 50.26±7.06 versus 45.42±7.53 (p=0.00005), total stroma 50.34±6.49 versus 45.46±6.96 (p=0.5×10-5) at 1 day and 3 months, respectively, whereas no statistically significant changes were found during LASIK follow-up. No significant differences were observed in OD values between both techniques at any time point, although SMILE showed a tendency for higher OD values than LASIK within the first postoperative month. Visumax presented a tendency for thicker caps than target (11.48±7.85 μm), but not for flaps (2.73±8.93 μm) (p=0.00003). CONCLUSIONS Both LASIK flaps and SMILE caps show a significant postoperative rethickening. SMILE corneas present higher optical densities than LASIK corneas in the early postoperative period, with a significant decrease thereafter and up to 3 months. These findings correlate with the delayed visual recovery observed after SMILE.
Collapse
Affiliation(s)
- Jorge Luis Alio Del Barrio
- Cornea, Cataract and Refractive Surgery Unit, VISSUM (Grupo Miranza), Alicante, Spain.,Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain
| | - Alberto Parafita-Fernandez
- Ophthalmology Department, Complexo Hospitalario Universitario de Pontevedra, Pontevedra, Spain.,Clínica Oftalmológica Dr Parafita, Ribeira, A Coruña, Spain
| | - Mario Canto-Cerdan
- Cornea, Cataract and Refractive Surgery Unit, VISSUM (Grupo Miranza), Alicante, Spain
| | - Jorge L Alio
- Cornea, Cataract and Refractive Surgery Unit, VISSUM (Grupo Miranza), Alicante, Spain.,Division of Ophthalmology, School of Medicine, Universidad Miguel Hernández, Alicante, Spain
| | - Miguel Teus
- Hospital Universitario Príncipe de Asturias, Universidad de Alcalá, Alcalá de Henares, Madrid, Spain .,Clínica Novovisión, Madrid, Spain
| |
Collapse
|