1
|
Slavin BV, Ehlen QT, Costello JP, Nayak VV, Bonfante EA, Benalcázar Jalkh EB, Runyan CM, Witek L, Coelho PG. 3D Printing Applications for Craniomaxillofacial Reconstruction: A Sweeping Review. ACS Biomater Sci Eng 2023; 9:6586-6609. [PMID: 37982644 DOI: 10.1021/acsbiomaterials.3c01171] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2023]
Abstract
The field of craniomaxillofacial (CMF) surgery is rich in pathological diversity and broad in the ages that it treats. Moreover, the CMF skeleton is a complex confluence of sensory organs and hard and soft tissue with load-bearing demands that can change within millimeters. Computer-aided design (CAD) and additive manufacturing (AM) create extraordinary opportunities to repair the infinite array of craniomaxillofacial defects that exist because of the aforementioned circumstances. 3D printed scaffolds have the potential to serve as a comparable if not superior alternative to the "gold standard" autologous graft. In vitro and in vivo studies continue to investigate the optimal 3D printed scaffold design and composition to foster bone regeneration that is suited to the unique biological and mechanical environment of each CMF defect. Furthermore, 3D printed fixation devices serve as a patient-specific alternative to those that are available off-the-shelf with an opportunity to reduce operative time and optimize fit. Similar benefits have been found to apply to 3D printed anatomical models and surgical guides for preoperative or intraoperative use. Creation and implementation of these devices requires extensive preclinical and clinical research, novel manufacturing capabilities, and strict regulatory oversight. Researchers, manufacturers, CMF surgeons, and the United States Food and Drug Administration (FDA) are working in tandem to further the development of such technology within their respective domains, all with a mutual goal to deliver safe, effective, cost-efficient, and patient-specific CMF care. This manuscript reviews FDA regulatory status, 3D printing techniques, biomaterials, and sterilization procedures suitable for 3D printed devices of the craniomaxillofacial skeleton. It also seeks to discuss recent clinical applications, economic feasibility, and future directions of this novel technology. By reviewing the current state of 3D printing in CMF surgery, we hope to gain a better understanding of its impact and in turn identify opportunities to further the development of patient-specific surgical care.
Collapse
Affiliation(s)
- Blaire V Slavin
- University of Miami Miller School of Medicine, 1011 NW 15th St., Miami, Florida 33136, United States
| | - Quinn T Ehlen
- University of Miami Miller School of Medicine, 1011 NW 15th St., Miami, Florida 33136, United States
| | - Joseph P Costello
- University of Miami Miller School of Medicine, 1011 NW 15th St., Miami, Florida 33136, United States
| | - Vasudev Vivekanand Nayak
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, 1011 NW 15th St., Miami, Florida 33136, United States
| | - Estavam A Bonfante
- Department of Prosthodontics and Periodontology, University of Sao Paulo, Bauru School of Dentistry, Alameda Dr. Octávio Pinheiro Brisolla, Quadra 9 - Jardim Brasil, Bauru São Paulo 17012-901, Brazil
| | - Ernesto B Benalcázar Jalkh
- Department of Prosthodontics and Periodontology, University of Sao Paulo, Bauru School of Dentistry, Alameda Dr. Octávio Pinheiro Brisolla, Quadra 9 - Jardim Brasil, Bauru São Paulo 17012-901, Brazil
| | - Christopher M Runyan
- Department of Plastic and Reconstructive Surgery, Wake Forest School of Medicine, 475 Vine St, Winston-Salem, North Carolina 27101, United States
| | - Lukasz Witek
- Biomaterials Division, NYU Dentistry, 345 E. 24th St., New York, New York 10010, United States
- Hansjörg Wyss Department of Plastic Surgery, NYU Grossman School of Medicine, New York University, 222 E 41st St., New York, New York 10017, United States
- Department of Biomedical Engineering, NYU Tandon School of Engineering, 6 MetroTech Center, Brooklyn, New York 11201, United States
| | - Paulo G Coelho
- Department of Biochemistry and Molecular Biology, University of Miami Miller School of Medicine, 1011 NW 15th St., Miami, Florida 33136, United States
- DeWitt Daughtry Family Department of Surgery, Division of Plastic Surgery, University of Miami Miller School of Medicine, 1120 NW 14th St., Miami, Florida 33136, United States
| |
Collapse
|
2
|
Wang Q, Telha W, Wu Y, Abotaleb B, Jiang N, Zhu S. Evaluation of the Properties of 3D-Printed Ti Alloy Plates: In Vivo and In Vitro Comparative Experimental Study. J Clin Med 2023; 12:jcm12020444. [PMID: 36675373 PMCID: PMC9860900 DOI: 10.3390/jcm12020444] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2022] [Revised: 12/31/2022] [Accepted: 01/01/2023] [Indexed: 01/09/2023] Open
Abstract
Titanium (Ti)-based implants play a significant role in rigid internal fixation in maxillofacial surgery. No study has reported that three-dimensional-printed Ti alloy plates (3D-Ti plates) have comprehensively excellent properties similar to standard plates (Matrix-MANDIBLE, SYNTHES, Switzerland) (Synthes-Ti plates). In this work, we manufactured 3D-Ti plates by selective laser melting with Ti6Al4V powder. The surface morphology, mechanical properties, and bone-plate contact rate of the 3D-Ti plates and the Synthes-Ti plates were characterized and compared via electron microscopy, atomic force microscopy, Vickers hardness test, three-point bending test, and software calculation. Human bone marrow stromal cells (HBMSCs) were cultured on the plates to test their biocompatibility. Importantly, the 3D-Ti plates were placed into a mandibular fracture model to assess the effect of medical application for 4 and 24 weeks. The 3D-Ti plates were demonstrated to have similar biocompatibility and stability for rigid internal fixation with the Synthes-Ti plates, lower roughness (106.44 ± 78.35 nm), better mechanical strength (370.78 ± 1.25 HV10), and a higher bone-plate contact rate (96.9%). These promising results indicate the feasibility of using 3D-Ti plates for irregular shapes and complex anatomical structures in a clinical context.
Collapse
Affiliation(s)
- Qi Wang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Wael Telha
- Department of Orthognathic and TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Yange Wu
- Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Bassam Abotaleb
- Department of Orthognathic and TMJ Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
| | - Nan Jiang
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Correspondence: (N.J.); (S.Z.)
| | - Songsong Zhu
- State Key Laboratory of Oral Diseases and National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu 610041, China
- Correspondence: (N.J.); (S.Z.)
| |
Collapse
|
3
|
You Y, Niu Y, Sun F, Huang S, Ding P, Wang X, Zhang X, Zhang J. Three-dimensional printing and 3D slicer powerful tools in understanding and treating neurosurgical diseases. Front Surg 2022; 9:1030081. [PMCID: PMC9614074 DOI: 10.3389/fsurg.2022.1030081] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2022] [Accepted: 09/28/2022] [Indexed: 11/13/2022] Open
Abstract
With the development of the 3D printing industry, clinicians can research 3D printing in preoperative planning, individualized implantable materials manufacturing, and biomedical tissue modeling. Although the increased applications of 3D printing in many surgical disciplines, numerous doctors do not have the specialized range of abilities to utilize this exciting and valuable innovation. Additionally, as the applications of 3D printing technology have increased within the medical field, so have the number of printable materials and 3D printers. Therefore, clinicians need to stay up-to-date on this emerging technology for benefit. However, 3D printing technology relies heavily on 3D design. 3D Slicer can transform medical images into digital models to prepare for 3D printing. Due to most doctors lacking the technical skills to use 3D design and modeling software, we introduced the 3D Slicer to solve this problem. Our goal is to review the history of 3D printing and medical applications in this review. In addition, we summarized 3D Slicer technologies in neurosurgery. We hope this article will enable many clinicians to leverage the power of 3D printing and 3D Slicer.
Collapse
Affiliation(s)
- Yijie You
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China
| | - Yunlian Niu
- Department of Neurology, Xinhua Hospital Chongming Branch, Shanghai, China
| | - Fengbing Sun
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China
| | - Sheng Huang
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China
| | - Peiyuan Ding
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China
| | - Xuhui Wang
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China,Department of Neurosurgery, Xinhua Hospital Affiliated to Shanghai JiaoTong University School of Medicine, The Cranial Nerve Disease Center of Shanghai JiaoTong University, Shanghai, China
| | - Xin Zhang
- Educational Administrative Department, Shanghai Chongming Health School, Shanghai, China,Correspondence: Xin Zhang Jian Zhang
| | - Jian Zhang
- Department of Neurosurgery, Xinhua Hospital Chongming Branch, Shanghai, China,Correspondence: Xin Zhang Jian Zhang
| |
Collapse
|
4
|
Mohd Sabee MMS, Ahmad Tajuddin NNI, Ku Ishak KM, Rusli A, Abdullah MK, Shafiq MD, Shuib RK, Abdul Hamid ZA. Comparison of physical and mechanical properties of biodegradable polybutylene adipate terephthalate, polycaprolactone, and poly(lactic acid) fabricated via fused deposition modeling and conventional molding. J Appl Polym Sci 2022. [DOI: 10.1002/app.52973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Mohd Meer Saddiq Mohd Sabee
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Nurul Nabilah Izzah Ahmad Tajuddin
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Ku Marsila Ku Ishak
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Arjulizan Rusli
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Muhammad Khalil Abdullah
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Mohamad Danial Shafiq
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Raa Khimi Shuib
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| | - Zuratul Ain Abdul Hamid
- Biomaterials Research Niche Group, School of Materials and Mineral Resources Engineering Universiti Sains Malaysia Nibong Tebal Pulau Pinang Malaysia
| |
Collapse
|
5
|
Rynio P, Wojtuń M, Wójcik Ł, Kawa M, Falkowski A, Gutowski P, Kazimierczak A. The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis. Quant Imaging Med Surg 2022; 12:1385-1396. [PMID: 35111632 DOI: 10.21037/qims-21-529] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2021] [Accepted: 10/13/2021] [Indexed: 12/21/2022]
Abstract
Background Advances in 3D printing technology allow us to continually find new medical applications. One of them is 3D printing of aortic templates to guide vascular surgeons or interventional radiologists to create fenestrations in the stent-graft surface for the implantation procedure called fenestrated endovascular aortic aneurysm repair. It is believed that the use of 3D printing significantly improves the quality of modified fenestrated stent-grafts. However, the accuracy and reliability of personalized 3D printed models of aortic templates are not well established. Methods Thirteen 3D printed templates of the visceral aorta and sixteen of the aortic arch and their corresponding computer tomography of angiography images were included in this accuracy study. The 3D models were scanned in the same conditions on computed tomography (CT) and evaluated by three physicians experienced in vascular CT assessment. Model and patient CT measurements were performed at key landmarks to maintain quality for stent-graft modification, including side branches and aortic diameters. CT-scanned aortic templates were segmented, aligned with sourced patient data, and evaluated for the Hausdorff matrix. Next, Bland-Altman plots determined the degree of agreement. Results The Intraclass Correlation Coefficients values were more than 0.9 for all measurements of aortic diameters and aortic branches diameter in all landmark locations. Therefore, the reliability of the aortic templates was considered excellent. The Bland-Altman plots analysis indicated measurement biases of 0.05 to 0.47 for aortic arch templates and 0.06 to 0.38 for reno-visceral aortic templates. The arithmetic mean of Hausdorff's mean distances of the aortic arch templates was 0.47 mm (SD =0.06) and ranged from 0.34 to 0.58. The mean metrics for abdominal models was 0.24 mm (SD =0.03) and ranged from 0.21 to 0.31. Conclusions The printed models of 3D aortic templates are accurate and reliable, thus can be widely used in endovascular surgery and interventional radiology departments as aortic templates to guide the physician-modified fenestrated stent-graft fabrication.
Collapse
Affiliation(s)
- Pawel Rynio
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Maciej Wojtuń
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Łukasz Wójcik
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Miłosz Kawa
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Aleksander Falkowski
- Department of Radiology, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Piotr Gutowski
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| | - Arkadiusz Kazimierczak
- Department of Vascular Surgery, Pomeranian Medical University in Szczecin, Szczecin, Poland
| |
Collapse
|
6
|
Asbai-Ghoudan R, Ruiz de Galarreta S, Rodriguez-Florez N. Analytical model for the prediction of permeability of triply periodic minimal surfaces. J Mech Behav Biomed Mater 2021; 124:104804. [PMID: 34481309 DOI: 10.1016/j.jmbbm.2021.104804] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 07/22/2021] [Accepted: 08/27/2021] [Indexed: 12/22/2022]
Abstract
Triply periodic minimal surfaces (TPMS) are mathematically defined cellular structures whose geometry can be quickly adapted to target desired mechanical response (structural and fluid). This has made them desirable for a wide range of bioengineering applications; especially as bioinspired materials for bone replacement. The main objective of this study was to develop a novel analytical framework which would enable calculating permeability of TPMS structures based on the desired architecture, pore size and porosity. To achieve this, computer-aided designs of three TPMS structures (Fisher-Koch S, Gyroid and Schwarz P) were generated with varying cell size and porosity levels. Computational Fluid Dynamics (CFD) was used to calculate permeability for all models under laminar flow conditions. Permeability values were then used to fit an analytical model dependent on geometry parameters only. Results showed that permeability of the three architectures increased with porosity at different rates, highlighting the importance of pore distribution and architecture. The computed values of permeability fitted well with the suggested analytical model (R2>0.99, p<0.001). In conclusion, the novel analytical framework presented in the current study enables predicting permeability values of TPMS structures based on geometrical parameters within a difference <5%. This model, which could be combined with existing structural analytical models, could open new possibilities for the smart optimisation of TPMS structures for biomedical applications where structural and fluid flow properties need to be optimised.
Collapse
Affiliation(s)
- Reduan Asbai-Ghoudan
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain.
| | - Sergio Ruiz de Galarreta
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain
| | - Naiara Rodriguez-Florez
- Department of Mechanical Engineering and Materials, Universidad de Navarra, TECNUN Escuela de Ingenieros, Paseo Manuel de Lardizabal, 13, 20018, San Sebastian, Spain; IKERBASQUE, Basque Foundation for Science, Plaza Euskadi 5, 48009, Bilbao, Spain
| |
Collapse
|
7
|
Sharma D, Mathur VP, Satapathy BK. Biodegradable and Biocompatible 3D Constructs for Dental Applications: Manufacturing Options and Perspectives. Ann Biomed Eng 2021; 49:2030-2056. [PMID: 34318403 DOI: 10.1007/s10439-021-02839-3] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Designing 3D constructs with appropriate materials and structural frameworks for complex dental restorative/regenerative procedures has always remained a multi-criteria optimization challenge. In this regard, 3D printing has long been known to be a potent tool for various tissue regenerative applications, however, the preparation of biocompatible, biodegradable, and stable inks is yet to be explored and revolutionized for overall performance improvisation. The review reports the currently employed manufacturing processes for the development of engineered self-supporting, easily processable, and cost-effective 3D constructs with target-specific tuneable mechanics, bioactivity, and degradability aspects in the oral cavity for their potential use in numerous dental applications ranging from soft pulp tissues to hard alveolar bone tissues. A hybrid synergistic approach, comprising of development of multi-layered, structurally stable, composite building blocks with desired physicomechanical performance and bioactivity presents an optimal solution to circumvent the major limitations and develop new-age advanced dental restorations and implants. Further, the review summarizes some manufacturing perspectives which may inspire the readers to design appropriate structures for clinical trials so as to pave the way for their routine applications in dentistry in the near future.
Collapse
Affiliation(s)
- Deepika Sharma
- Department of Materials Science and Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India
| | - Vijay Prakash Mathur
- Division of Pedodontics and Preventive Dentistry, Centre for Dental Education and Research, All India Institute of Medical Sciences, New Delhi, 110029, India
| | - Bhabani K Satapathy
- Department of Materials Science and Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India.
| |
Collapse
|
8
|
Alhazmi B, Alshomer F, Alawirdhi B. Multiscale sterilizable 3D printed auricular templates to guide cartilaginous framework sizing and sculpture during autologous microtia reconstruction. JPRAS Open 2021; 28:121-125. [PMID: 33855150 PMCID: PMC8027526 DOI: 10.1016/j.jpra.2021.03.004] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 03/12/2021] [Indexed: 11/24/2022] Open
Abstract
Microtia reconstruction using autologous costal cartilage can be one of the most challenging tasks in reconstructive surgery. An intraoperative guide using 2-dimentional drawing of the contralateral ear on an x-ray film remains the current standard of care. In this paper, we present the use of computer-aided design and desktop 3D printing to fabricate low cost, sterilizable auricular carving templates to serve as a peri-operative reference for microtia reconstruction. The design was made as a single component which incorporated the usual anatomic reference points of the ear based on Nagata technique as a Stereo-lithography file format (. STL) for 3D printing. The templates were created in sizes ranging from 55 mm to 70 mm with a 2 mm increment with an average production cost of 0.26 US dollars per material per template and about 4.5 US dollars for the whole set. Individual templates were then 3D-printed using a thermoplastic polyurethane (TPU 95A) semiflexible filament on a desktop fused deposition modeling, Ultimaker 2 + 3D printer. The produced template tolerated the sterilization process with no structural changes as compared to its pre-sterilization condition. In conclusion, we present cost-effective, sterilizable, multiscale auricular templates to guide the pre- and intra-operative carving of the cartilaginous framework during microtia reconstruction with more accuracy in a time efficient manner, thereby overcoming the drawbacks of using the traditional x-ray film. The templates are readily accessible and sharable for free through open-source software and can be directly 3D-printed using an affordable desktop 3D printer.
Collapse
Affiliation(s)
- Bushra Alhazmi
- Division of Plastic Surgery, Department of Surgery, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia
| | - Feras Alshomer
- Division of Plastic Surgery, Department of Surgery, King Abdulaziz Medical City, Ministry of National Guard - Health Affairs, Riyadh, Saudi Arabia.,King Abdullah International Medical Research Center, Riyadh, Saudi Arabia
| | - Bassam Alawirdhi
- Department of Plastic Surgery, Prince Sultan Military Medical City, Riyadh, Saudi Arabia
| |
Collapse
|