• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4641775)   Today's Articles (134)   Subscriber (50458)
For: Souffrant R, Zietz C, Fritsche A, Kluess D, Mittelmeier W, Bader R. Advanced material modelling in numerical simulation of primary acetabular press-fit cup stability. Comput Methods Biomech Biomed Engin 2012;15:787-93. [DOI: 10.1080/10255842.2011.561012] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Number Cited by Other Article(s)
1
Modeling the debonding process of osseointegrated implants due to coupled adhesion and friction. Biomech Model Mechanobiol 2023;22:133-158. [PMID: 36284076 PMCID: PMC9957925 DOI: 10.1007/s10237-022-01637-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2022] [Accepted: 09/06/2022] [Indexed: 11/02/2022]
2
Determinants of the primary stability of cementless acetabular cup implants: A 3D finite element study. Comput Biol Med 2021;135:104607. [PMID: 34242871 DOI: 10.1016/j.compbiomed.2021.104607] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 05/31/2021] [Accepted: 06/22/2021] [Indexed: 11/20/2022]
3
Comparison of Test Setups for the Experimental Evaluation of the Primary Fixation Stability of Acetabular Cups. MATERIALS 2020;13:ma13183982. [PMID: 32916802 PMCID: PMC7559462 DOI: 10.3390/ma13183982] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 08/28/2020] [Accepted: 09/03/2020] [Indexed: 11/22/2022]
4
Fixation Stability of Uncemented Acetabular Cups With Respect to Different Bone Defect Sizes. J Arthroplasty 2020;35:1720-1728. [PMID: 32063411 DOI: 10.1016/j.arth.2020.01.019] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Revised: 12/23/2019] [Accepted: 01/09/2020] [Indexed: 02/01/2023]  Open
5
Weißmann V, Ramskogler T, Schulze C, Bader R, Hansmann H. Influence of Synthetic Bone Substitutes on the Anchorage Behavior of Open-Porous Acetabular Cup. MATERIALS (BASEL, SWITZERLAND) 2019;12:E1052. [PMID: 30935040 PMCID: PMC6479851 DOI: 10.3390/ma12071052] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 03/25/2019] [Accepted: 03/26/2019] [Indexed: 11/17/2022]
6
Schulze C, Vogel D, Sander M, Bader R. Calibration of crushable foam plasticity models for synthetic bone material for use in finite element analysis of acetabular cup deformation and primary stability. Comput Methods Biomech Biomed Engin 2018;22:25-37. [PMID: 30449160 DOI: 10.1080/10255842.2018.1524884] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
7
Experimental Characterization of the Primary Stability of Acetabular Press-Fit Cups with Open-Porous Load-Bearing Structures on the Surface Layer. METALS 2018. [DOI: 10.3390/met8100839] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
8
Weißmann V, Boss C, Bader R, Hansmann H. A novel approach to determine primary stability of acetabular press-fit cups. J Mech Behav Biomed Mater 2018;80:1-10. [PMID: 29414463 DOI: 10.1016/j.jmbbm.2018.01.015] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2017] [Revised: 11/11/2017] [Accepted: 01/16/2018] [Indexed: 11/28/2022]
9
Experimental and computational analysis of micromotions of an uncemented femoral knee implant using elastic and plastic bone material models. J Biomech 2017;61:137-143. [DOI: 10.1016/j.jbiomech.2017.07.023] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 07/05/2017] [Accepted: 07/16/2017] [Indexed: 11/22/2022]
10
Vayron R, Nguyen VH, Bosc R, Naili S, Haïat G. Assessment of the biomechanical stability of a dental implant with quantitative ultrasound: A three-dimensional finite element study. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016;139:773-780. [PMID: 26936559 DOI: 10.1121/1.4941452] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
11
Finite element simulation of ultrasonic wave propagation in a dental implant for biomechanical stability assessment. Biomech Model Mechanobiol 2015;14:1021-32. [PMID: 25619479 DOI: 10.1007/s10237-015-0651-7] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2014] [Accepted: 01/10/2015] [Indexed: 12/31/2022]
12
Vayron R, Mathieu V, Michel A, Haïat G. Assessment of in vitro dental implant primary stability using an ultrasonic method. ULTRASOUND IN MEDICINE & BIOLOGY 2014;40:2885-2894. [PMID: 25308939 DOI: 10.1016/j.ultrasmedbio.2014.03.035] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2013] [Revised: 03/05/2014] [Accepted: 03/06/2014] [Indexed: 06/04/2023]
13
Ultrasonic evaluation of dental implant osseointegration. J Biomech 2014;47:3562-8. [PMID: 25262877 DOI: 10.1016/j.jbiomech.2014.07.011] [Citation(s) in RCA: 41] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 07/08/2014] [Accepted: 07/13/2014] [Indexed: 01/22/2023]
14
Kelly N, Cawley D, Shannon F, McGarry J. An investigation of the inelastic behaviour of trabecular bone during the press-fit implantation of a tibial component in total knee arthroplasty. Med Eng Phys 2013;35:1599-606. [DOI: 10.1016/j.medengphy.2013.05.007] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 04/25/2013] [Accepted: 05/16/2013] [Indexed: 11/28/2022]
15
Mathieu V, Michel A, Flouzat Lachaniette CH, Poignard A, Hernigou P, Allain J, Haïat G. Variation of the impact duration during the in vitro insertion of acetabular cup implants. Med Eng Phys 2013;35:1558-63. [DOI: 10.1016/j.medengphy.2013.04.005] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2012] [Revised: 04/07/2013] [Accepted: 04/17/2013] [Indexed: 10/26/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA