1
|
Liang Z, Mo F, Zheng Z, Li Y, Tian Y, Jiang X, Liu T. Quantitative cervical spine injury responses in whiplash loading with a numerical method of natural neural reflex consideration. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2022; 219:106761. [PMID: 35344767 DOI: 10.1016/j.cmpb.2022.106761] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 03/07/2022] [Accepted: 03/15/2022] [Indexed: 06/14/2023]
Abstract
BACKGROUND AND OBJECTIVE Neural reflex is hypothesized as a regulating step in spine stabilizing system. However, neural reflex control is still in its infancy to consider in the previous finite element analysis of head-neck system for various applications. The purpose of this study is to investigate the influences of neural reflex control on neck biomechanical responses, then provide a new way to achieve an accurate biomechanical analysis for head-neck system with a finite element model. METHODS A new FE head-neck model with detailed active muscles and spinal cord modeling was established and globally validated at multi-levels. Then, it was coupled with our previously developed neuromuscular head-neck model to analyze the effects of vestibular and proprioceptive reflexes on biomechanical responses of head-neck system in a typical spinal injury loading condition (whiplash). The obtained effects were further analyzed by comparing a review of epidemiologic data on cervical spine injury situations. RESULT The results showed that the active model (AM) with neural reflex control obviously presented both rational head-neck kinematics and tissue injury risk referring to the previous experimental and epidemiologic studies, when compared with the passive model (PM) without it. Tissue load concentration locations as well as stress/strain levels were both changed due to the muscle activation forces caused by neural reflex control during the whole loading process. For the bony structures, the AM showed a peak stress level accounting for only about 25% of the PM. For the discs, the stress concentrated location was transferred from C2-C6 in the PM to C4-C6 in the AM. For the spinal cord, the strain concentrated locations were transferred from C1 segment to around C4 segment when the effects of neural reflex control were implemented, while the gray matter and white matter peak strains were reduced to 1/3 and 1/2 of the PM, respectively. All these were well correlated with epidemiological studies on clinical cervical spine injuries. CONCLUSION In summary, the present work demonstrated necessity of considering neural reflex in FE analysis of a head-neck system as well as our model biofidelity. Overall results also verified the previous hypothesis and further quantitatively indicated that the muscle activation caused by neural reflex is providing a protection for the neck in impact loading by decreasing the strain level and changing the possible injury to lower spinal cord level to reduce injury severity.
Collapse
Affiliation(s)
- Ziyang Liang
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan 410082, China; Department of Orthopedics, The Second Xiangya Hospital of Central South University, Changsha, Hunan 410011, China
| | - Fuhao Mo
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan 410082, China.
| | - Zhefen Zheng
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan 410082, China
| | - Yuandong Li
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan 410082, China
| | - Ye Tian
- College of Mechanical and Vehicle Engineering, Hunan University, Changsha, Hunan 410082, China
| | - Xiaobing Jiang
- Department of Spine Surgery, Guangzhou University of Chinese medicine, Guangzhou, Guangdong 510405, China
| | - Tang Liu
- Department of Orthopedics, The Second Xiangya Hospital of Central South University, Changsha, Hunan 410011, China
| |
Collapse
|
2
|
Wang F, Jia S, Li M, Pan K, Zhang J, Fan Y. Effect of the medial collateral ligament and the lateral ulnar collateral ligament injury on elbow stability: a finite element analysis. Comput Methods Biomech Biomed Engin 2021; 24:1517-1529. [PMID: 33715549 DOI: 10.1080/10255842.2021.1898601] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
Ligaments are the most important stabilizer of elbow. However, the stress of ligaments is hard to measure because of the complex biomechanical environment in the elbow. Our objective was to develop a human elbow finite element model and to validate it by a comparison with previous experimental data. Then several different ligaments injury conditions and elbow flexion were simulated to analyse the elbow instability and to stress the biomechanical consequences. The computational investigation of different effects of ligament constraints of elbow was studied by means of finite element analysis. The stress of the anterior bundle was almost greater than other ligaments in all conditions, which played the most important role during the elbow flexion. The posterior bundle was the secondary stabilizer during flexion after the anterior bundle. The lateral ulnar collateral ligament (LUCL) injury could result in an increase of the ulnar cartilage stress. The anterior bundle and the LUCL were recommended to be repaired in elbow joint dislocations and fractures. This study could help understand the dynamic effects of ligaments on the joint over the entire extension by investigating the tissue stress.
Collapse
Affiliation(s)
- Fang Wang
- College of Mechanical Engineering, Tianjin University of Science & Technology, No. 1038, Dagu Nanlu, Hexi District, Tianjin, China.,Tianjin Key Lab of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, Tianjin, China.,National Research Centre for Rehabilitation Technical Aids, No. 1, Ronghuazhonglu, BDA, Beijing, China.,Beijing Key Laboratory of Rehabilitation Technical Aids for Old-Age Disability, No.1, Ronghuazhonglu, BDA, Beijing, China
| | - Shuoqi Jia
- College of Mechanical Engineering, Tianjin University of Science & Technology, No. 1038, Dagu Nanlu, Hexi District, Tianjin, China
| | - Mingxin Li
- Department of Traumatic Orthopaedics, Tianjin Hospital, No. 406, Jiefang Nanlu, Hexi District, Tianjin, China
| | - Kui Pan
- College of Mechanical Engineering, Tianjin University of Science & Technology, No. 1038, Dagu Nanlu, Hexi District, Tianjin, China
| | - Jianguo Zhang
- College of Mechanical Engineering, Tianjin University of Science & Technology, No. 1038, Dagu Nanlu, Hexi District, Tianjin, China.,Tianjin Key Lab of Integrated Design and On-line Monitoring for Light Industry & Food Machinery and Equipment, Tianjin, China
| | - Yubo Fan
- Beijing Advanced Innovation Centre for Biomedical Engineering, Key Laboratory for Biomechanics and Mechanobiology of Chinese Education Ministry, School of Biological Science and Medical Engineering, Beihang University, No.37, Xueyuan Road, Haidian District, Beijing, China.,School of Engineering Medicine, Beihang University, No.37, Xueyuan Road, Haidian District, Beijing, China
| |
Collapse
|
3
|
Zhang H, Mo F, Wang L, Behr M, Arnoux PJ. A Framework of a Lower Limb Musculoskeletal Model With Implemented Natural Proprioceptive Feedback and Its Progressive Evaluation. IEEE Trans Neural Syst Rehabil Eng 2020; 28:1866-1875. [DOI: 10.1109/tnsre.2020.3003497] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
4
|
Mo F, Li J, Dan M, Liu T, Behr M. Implementation of controlling strategy in a biomechanical lower limb model with active muscles for coupling multibody dynamics and finite element analysis. J Biomech 2019; 91:51-60. [PMID: 31101432 DOI: 10.1016/j.jbiomech.2019.05.001] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 05/02/2019] [Accepted: 05/04/2019] [Indexed: 11/28/2022]
Abstract
Computational biomechanics for human body modeling has generally been categorized into two separated domains: finite element analysis and multibody dynamics. Combining the advantages of both domains is necessary when tissue stress and physical body motion are both of interest. However, the method for this topic is still in exploration. The aim of this study is to implement unique controlling strategies in finite element model for simultaneously simulating musculoskeletal body dynamics and in vivo stress inside human tissues. A finite element lower limb model with 3D active muscles was selected for the implementation of controlling strategies, which was further validated against in-vivo human motion experiments. A unique feedback control strategy that couples together a basic Proportion-Integration-Differentiation (PID) controller and generic active signals from Computed Muscle Control (CMC) method of the musculoskeletal model or normalized EMG singles was proposed and applied in the present model. The results show that the new proposed controlling strategy show a good correlation with experimental test data of the normal gait considering joint kinematics, while stress distribution of local lower limb tissue can be also detected in real-time with lower limb motion. In summary, the present work is the first step for the application of active controlling strategy in the finite element model for concurrent simulation of both body dynamics and tissue stress. In the future, the present method can be further developed to apply it in various fields for human biomechanical analysis to monitor local stress and strain distribution by simultaneously simulating human locomotion.
Collapse
Affiliation(s)
- Fuhao Mo
- State Key Laboratory of Advanced Design and Manufacture for Vehicle Body, Hunan University, Changsha, Hunan 410082, China; Aix-Marseille University, IFSTTAR, LBA UMRT24, Faculté de Médecine Nord, Boulevard Pierre Dramard, 13916 Marseille Cedex 20, France
| | - Junjie Li
- State Key Laboratory of Advanced Design and Manufacture for Vehicle Body, Hunan University, Changsha, Hunan 410082, China
| | - Minchao Dan
- State Key Laboratory of Advanced Design and Manufacture for Vehicle Body, Hunan University, Changsha, Hunan 410082, China
| | - Tang Liu
- Department of Orthopedics, The Second Xiangya Hospital of Central South University, 139 Renmin Road, Changsha, Hunan 410011, China.
| | - Michel Behr
- Aix-Marseille University, IFSTTAR, LBA UMRT24, Faculté de Médecine Nord, Boulevard Pierre Dramard, 13916 Marseille Cedex 20, France
| |
Collapse
|