1
|
Nyssen P, Maho A, Malempre R, Matagne A, Mouithys-Mickalad A, Hoebeke M. Propofol inhibits the myeloperoxidase activity by acting as substrate through a redox process. Biochim Biophys Acta Gen Subj 2022; 1866:130100. [PMID: 35150774 DOI: 10.1016/j.bbagen.2022.130100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Revised: 02/01/2022] [Accepted: 02/01/2022] [Indexed: 01/13/2023]
Abstract
BACKGROUND Propofol (2,6-diisopropylphenol) is frequently used as intravenous anesthetic agent, especially in its injectable form (Diprivan), to initiate and maintain sedative state during surgery or in intensive care units. Numerous studies have reported the antioxidant and anti-inflammatory effect of propofol. The oxidant enzyme myeloperoxidase (MPO), released from activated neutrophils, plays a key role in host defense. An increase of the circulating MPO concentration has been observed in patients admitted in intensive care unit and presenting a systemic inflammatory response related to septic shock or trauma. METHODS This study investigates the immunomodulatory action of propofol and Diprivan as inhibitor of the oxidant activity of MPO. The understanding of the redox action mechanism of propofol and Diprivan on the myeloperoxidase chlorination and peroxidase activities has been refined using the combination of fluorescence and absorption spectroscopies with docking and cyclic voltammetry. RESULTS Propofol acts as a reversible MPO inhibitor. The molecule interacts as a reducing substrate in the peroxidase cycle and promotes the accumulation of compound II. At acidic pH (5.5), propofol and Diprivan do not inhibit the chlorination activity, but their action increases at physiological pH (7.4). The main inhibitory action of Diprivan could be attributed to its HOCl scavenging property. GENERAL SIGNIFICANCE Propofol can act as a reversible MPO inhibitor at clinical concentrations. This property could, in addition to other previously proven anti-inflammatory actions, induce an immunomodulatory action, beneficial during clinical use, particularly in the treatment of systemic inflammation response syndrome.
Collapse
Affiliation(s)
- P Nyssen
- Biomedical Spectroscopy Laboratory, Department of Physics, CESAM, University of Liège, Building B5a, Quartier Agora, Allée du 6 Août, 19, Sart-Tilman, 4000 Liège, Belgium.
| | - A Maho
- Greenmat, Department of Chemistry, CESAM, University of Liège, Building B6c, Quartier Agora, Allée du 6 Août, 19, Sart-Tilman, 4000 Liège, Belgium
| | - R Malempre
- Laboratory of Enzymology and Protein folding, Centre for Protein Engineering, InBioS, University of Liège, Building B6a, Quartier Agora, Allée du 6 Août, 19, Sart-Tilman, 4000 Liège, Belgium
| | - A Matagne
- Laboratory of Enzymology and Protein folding, Centre for Protein Engineering, InBioS, University of Liège, Building B6a, Quartier Agora, Allée du 6 Août, 19, Sart-Tilman, 4000 Liège, Belgium
| | - A Mouithys-Mickalad
- CORD, Department of Chemistry, CIRM, University of Liège, Building B6a, Quartier Agora, Allée du 6 Août, 13, Sart-Tilman, 4000 Liège, Belgium
| | - M Hoebeke
- Biomedical Spectroscopy Laboratory, Department of Physics, CESAM, University of Liège, Building B5a, Quartier Agora, Allée du 6 Août, 19, Sart-Tilman, 4000 Liège, Belgium
| |
Collapse
|
2
|
Ferrier DC, Kiely J, Luxton R. Propofol detection for monitoring of intravenous anaesthesia: a review. J Clin Monit Comput 2021; 36:315-323. [PMID: 34213720 PMCID: PMC9123036 DOI: 10.1007/s10877-021-00738-5] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2020] [Accepted: 06/28/2021] [Indexed: 11/03/2022]
Abstract
This paper presents a review of established and emerging methods for detecting and quantifying the intravenous anaesthetic propofol in solution. There is growing evidence of numerous advantages of total intravenous anaesthesia using propofol compared to conventional volatile-based anaesthesia, both in terms of patient outcomes and environmental impact. However, volatile-based anaesthesia still accounts for the vast majority of administered general anaesthetics, largely due to a lack of techniques for real-time monitoring of patient blood propofol concentration. Herein, propofol detection techniques that have been developed to date are reviewed alongside a discussion of remaining challenges.
Collapse
Affiliation(s)
- David C Ferrier
- Institute of Bio-Sensing Technology, University of the West of England, Frenchay Campus, Bristol, BS16 1QY, UK.
| | - Janice Kiely
- Institute of Bio-Sensing Technology, University of the West of England, Frenchay Campus, Bristol, BS16 1QY, UK
| | - Richard Luxton
- Institute of Bio-Sensing Technology, University of the West of England, Frenchay Campus, Bristol, BS16 1QY, UK
| |
Collapse
|
3
|
Kivlehan F, Chaum E, Lindner E. Propofol detection and quantification in human blood: the promise of feedback controlled, closed-loop anesthesia. Analyst 2015; 140:98-106. [PMID: 25327876 DOI: 10.1039/c4an01483a] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The performance of a membrane-coated voltammetric sensor for propofol (2,6-diisopropylphenol) has been characterized in long term monitoring experiments using an automated flow analytical system (AFAS) and by analyzing human serum and whole blood samples by standard addition. It is shown that the signal of the membrane-coated electrochemical sensor for propofol is not influenced by the components of the pharmaceutical formulation of propofol (propofol injectable emulsion). The current values recorded with the electrochemical propofol sensor in buffer solutions and human serum samples spiked with propofol injectable emulsion showed excellent correlation with the peak heights recorded with an UV-Vis detector during the HPLC analysis of these samples (R(2) = 0.997 in PBS and R(2) = 0.975 in human serum). However, the determination of propofol using the electrochemical method is simpler, faster and has a better detection limit (0.08 ± 0.05 μM) than the HPLC method (0.4 ± 0.2 μM). As a first step towards feedback controlled closed-loop anesthesia, the membrane-coated electrochemical sensor has been implemented onto surface of an intravenous catheter. The response characteristics of the membrane-coated carbon fiber electrode on the catheter surface were very similar to those seen using a macroelectrode.
Collapse
Affiliation(s)
- Francine Kivlehan
- Department of Biomedical Engineering, University of Memphis, Memphis, Tennessee 38152, USA.
| | | | | |
Collapse
|
4
|
Karim K, Giannoudi L, Piletska E, Chianella I, Henry OY, Laitenberger P, Piletsky SA, Cowen T. Development of MIP sensor for monitoring propofol in clinical procedures. ACTA ACUST UNITED AC 2015. [DOI: 10.1080/22243682.2015.1031278] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
5
|
Rainey F, Kivlehan F, Chaum E, Lindner E. Toward Feedback Controlled Anesthesia: Automated Flow Analytical System for Electrochemical Monitoring of Propofol in Serum Solutions. ELECTROANAL 2014. [DOI: 10.1002/elan.201300585] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
6
|
Kivlehan F, Garay F, Guo J, Chaum E, Lindner E. Toward feedback-controlled anesthesia: voltammetric measurement of propofol (2,6-diisopropylphenol) in serum-like electrolyte solutions. Anal Chem 2012; 84:7670-6. [PMID: 22900668 DOI: 10.1021/ac3006878] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Propofol is a widely used, potent intravenous anesthetic for ambulatory anesthesia and long-term sedation. The target steady state concentration of propofol in blood is 0.25-10 μg/mL (1-60 μM). Although propofol can be oxidized electrochemically, monitoring its concentration in biological matrixes is very challenging due to (i) low therapeutic concentration, (ii) high concentrations of easily oxidizable interfering compounds in the sample, and (iii) fouling of the working electrode. In this work we report the performance characteristics of an organic film coated glassy carbon (GC) electrode for continuous monitoring of propofol. The organic film (a plasticized PVC membrane) improved the detection limit and the selectivity of the voltammetric sensor due to the large difference in hydrophobicity between the analyte (propofol) and interfering compounds of the sample, e.g., ascorbic acid (AA) or p-acetamidophenol (APAP). Furthermore, the membrane coating prevented electrode fouling and served as a protective barrier against electrode passivation by proteins. Studies revealed that sensitivity and selectivity of the voltammetric method is greatly influenced by the composition of the PVC membrane. The detection limit of the membrane-coated sensor for propofol in PBS is reported as 0.03 ± 0.01 μM. In serum-like electrolyte solutions containing physiologically relevant levels of albumin (5%) and 3 mM AA and 1 mM APAP as interfering agents, the detection limit was 0.5 ± 0.4 μM. Both values are below the target concentrations used clinically during anesthesia or sedation.
Collapse
Affiliation(s)
- Francine Kivlehan
- Department of Biomedical Engineering, University of Memphis, Tennessee 38152, USA
| | | | | | | | | |
Collapse
|
7
|
Friaa O, Maillard P, Brault D. Reaction of the m-THPC triplet state with the antioxidant Trolox and the anesthetic Propofol: Modulation of photosensitization mechanisms relevant to photodynamic therapy? Photochem Photobiol Sci 2012; 11:703-14. [DOI: 10.1039/c2pp05354c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
8
|
Langmaier J, Garay F, Kivlehan F, Chaum E, Lindner E. Electrochemical quantification of 2,6-diisopropylphenol (propofol). Anal Chim Acta 2011; 704:63-7. [PMID: 21907022 DOI: 10.1016/j.aca.2011.08.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2011] [Revised: 07/19/2011] [Accepted: 08/02/2011] [Indexed: 11/24/2022]
Abstract
2,6-Diisopropylphenol (propofol) is a potent anesthetic drug with fast onset of the anesthetic effect and short recovery time for the patients. Outside of the United States, propofol is widely used in performing target controlled infusion anesthesia. With the long term vision of an electrochemical sensor for in vivo monitoring and feedback controlled dosing of propofol in blood, different alternatives for the electrochemical quantification of propofol using diverse working electrodes and experimental conditions are presented in this contribution. When the electrochemical oxidation of propofol takes place on a glassy carbon working electrode, an electrochemically active film grows on the electrode surface. The reduction current of the film is proportional to the propofol concentration and the accumulation time. Based on these findings a stripping analytical method was developed for the detection of propofol in acidic solutions between 0 and 30 μM, with a detection limit of 5.5±0.4 μM. By restricting the scanned potential window between 0.5 V and 1.0 V in cyclic voltammetric experiments, the formation of the electrochemically active polymer can be prevented. This allowed the development of a direct voltammetric method for assessing propofol in acidic solutions between 0 and 30 μM, with a 3.2±0.1 μM (n=3) detection limit. The stripping method has a better sensitivity but somewhat worse reproducibility because the electrode surface has to be renewed between each experiment. The direct method does not require the renewal of the electrode surface between measurements but has no adequate selectivity towards the common interfering compounds.
Collapse
Affiliation(s)
- Jan Langmaier
- Department of Biomedical Engineering, University of Memphis, Memphis, TN 38152-3210, United States
| | | | | | | | | |
Collapse
|