Yang Y, Gu D, Aisa HA, Ito Y. Studies on the effect of column angle in figure-8 centrifugal counter-current chromatography.
J Chromatogr A 2010;
1218:6128-34. [PMID:
21134675 DOI:
10.1016/j.chroma.2010.11.014]
[Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2010] [Revised: 10/15/2010] [Accepted: 11/10/2010] [Indexed: 11/18/2022]
Abstract
The performance of the figure-8 column configuration in centrifugal counter-current chromatography was investigated by changing the angle between the column axis (a line through the central post and the peripheral post on which the figure-8 coil is wound) and the centrifugal force. The first series of experiments was performed using a polar two-phase solvent system composed of 1-butanol-acetic acid-water (4:1:5, v/v) to separate two dipeptide samples, Trp-Tyr and Val-Tyr, at a flow rate of 0.05 ml/min at 1000 rpm. When the column angle was changed from 0° (column axis parallel to the centrifugal force) to 45° and 45° to 90° (column axis perpendicular to the centrifugal force), peak resolution (Rs) changed from 1.93 (Sf=37.8%) to 1.54 (Sf=30.6%), then to 1.31 (Sf=40.5%) with the lower mobile phase and from 1.21 (Sf=38.8%) to 1.10 (Sf=34.4%), then to 0.99 (Sf=42.2%) with the upper mobile phase, respectively, where the stationary phase retention, Sf, is given in parentheses. The second series of experiments was similarly performed with a more hydrophobic two-phase solvent system composed of hexane-ethyl acetate-methanol-0.1M hydrochloric acid (1:1:1:1, v/v) to separate three DNP-amino acids, DNP-glu, DNP-β-ala and DNP-ala, at a flow rate of 0.05 ml/min at 1000 rpm. When the column angle was altered from 0° to 45° and 45° to 90°, Rs changed from 1.77 (1st peak/2nd peak) and 1.52 (2nd peak/3rd peak) (Sf=27.3%) to 1.24 and 1.02 (Sf=35.4%), then to 1.69 and 1.49 (Sf=42.1%) with the lower mobile phase, and from 1.73 and 0.84 (SF=41.2%) to 1.44 and 0.73 (Sf=45.6%), then to 1.21 and 0.63 (Sf=55.6%) with the upper mobile phase, respectively. The performance of figure-8 column at 0° and 90° was also compared at different flow rates. The results show that Rs was increased with decreased flow rate yielding the highest value at the 0° column angle with lower mobile phase. The overall results of our studies indicated that a 0° column angle for the figure-8 column enhances the mixing of two phases in the column to improve peak resolution while decreasing the stationary phase retention by interrupting the laminar flow of the mobile phase.
Collapse