Ameyibor E, Stewart JT. Resolution and quantitation of pentazocine enantiomers in human serum by reversed-phase high-performance liquid chromatography using sulfated beta-cyclodextrin as chiral mobile phase additive and solid-phase extraction.
JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 1997;
703:273-8. [PMID:
9448087 DOI:
10.1016/s0378-4347(97)00408-8]
[Citation(s) in RCA: 19] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A sensitive and stereospecific HPLC method was developed for the analysis of (-)- and (+)-pentazocine in human serum. The assay involves the use of a phenyl solid-phase extraction column for serum sample clean-up prior to HPLC analysis. Chromatographic resolution of the pentazocine enantiomers was performed on a octadecylsilane column with sulfated-beta-cyclodextrin (S-beta-CD) as the chiral mobile phase additive. The composition of the mobile phase was aqueous 10 mM potassium dihydrogenphosphate buffer pH 5.8 (adjusted with phosphoric acid)-absolute ethanol (80:20, v/v) containing 10 mM S-beta-CD at a flow-rate of 0.7 ml/min. Recoveries of (-)- and (+)-pentazocine were in the range of 91-93%. Linear calibration curves were obtained in the 20-400 ng/ml range for each enantiomer in serum. The detection limit based on S/N=3 was 15 ng/ml for each pentazocine enantiomer in serum with UV detection at 220 nm. The limit of quantitation for each enantiomer was 20 ng/ml. Precision calculated as R.S.D. and accuracy calculated as error were in the range 0.9-7.0% and 1.2-6.2%, respectively, for the (-)-enantiomer and 0.8- 7.6% and 1.2-4.6%, respectively, for the (+)-enantiomer (n=3).
Collapse