1
|
López LR, Dessì P, Cabrera-Codony A, Rocha-Melogno L, Kraakman B, Naddeo V, Balaguer MD, Puig S. CO 2 in indoor environments: From environmental and health risk to potential renewable carbon source. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 856:159088. [PMID: 36181799 DOI: 10.1016/j.scitotenv.2022.159088] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Revised: 09/10/2022] [Accepted: 09/24/2022] [Indexed: 06/16/2023]
Abstract
In the developed world, individuals spend most of their time indoors. Poor Indoor Air Quality (IAQ) has a wide range of effects on human health. The burden of disease associated with indoor air accounts for millions of premature deaths related to exposure to Indoor Air Pollutants (IAPs). Among them, CO2 is the most common one, and is commonly used as a metric of IAQ. Indoor CO2 concentrations can be significantly higher than outdoors due to human metabolism and activities. Even in presence of ventilation, controlling the CO2 concentration below the Indoor Air Guideline Values (IAGVs) is a challenge, and many indoor environments including schools, offices and transportation exceed the recommended value of 1000 ppmv. This is often accompanied by high concentration of other pollutants, including bio-effluents such as viruses, and the importance of mitigating the transmission of airborne diseases has been highlighted by the COVID-19 pandemic. On the other hand, the relatively high CO2 concentration of indoor environments presents a thermodynamic advantage for direct air capture (DAC) in comparison to atmospheric CO2 concentration. This review aims to describe the issues associated with poor IAQ, and to demonstrate the potential of indoor CO2 DAC to purify indoor air while generating a renewable carbon stream that can replace conventional carbon sources as a building block for chemical production, contributing to the circular economy.
Collapse
Affiliation(s)
- L R López
- LEQUiA, Institute of Environment, University of Girona, Campus Montilivi, carrer Maria Aurelia Capmany 69, Girona, Spain.
| | - P Dessì
- LEQUiA, Institute of Environment, University of Girona, Campus Montilivi, carrer Maria Aurelia Capmany 69, Girona, Spain
| | - A Cabrera-Codony
- LEQUiA, Institute of Environment, University of Girona, Campus Montilivi, carrer Maria Aurelia Capmany 69, Girona, Spain
| | - L Rocha-Melogno
- ICF, 2635 Meridian Parkway Suite 200, Durham, NC 27713, United States
| | - B Kraakman
- Jacobs Engineering, Templey Quay 1, Bristol BAS1 6DG, UK; Institute of Sustainable Processes, University of Valladolid, Dr. Mergelina s/n., 47011 Valladolid, Spain
| | - V Naddeo
- Sanitary Environmental Engineering Division, Department of Civil Engineering, University of Salerno, 84084 Fisciano, SA, Italy
| | - M D Balaguer
- LEQUiA, Institute of Environment, University of Girona, Campus Montilivi, carrer Maria Aurelia Capmany 69, Girona, Spain
| | - S Puig
- LEQUiA, Institute of Environment, University of Girona, Campus Montilivi, carrer Maria Aurelia Capmany 69, Girona, Spain
| |
Collapse
|
2
|
Shen G, Ainiwaer S, Zhu Y, Zheng S, Hou W, Shen H, Chen Y, Wang X, Cheng H, Tao S. Quantifying source contributions for indoor CO 2 and gas pollutants based on the highly resolved sensor data. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2020; 267:115493. [PMID: 33254594 DOI: 10.1016/j.envpol.2020.115493] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2020] [Revised: 08/16/2020] [Accepted: 08/20/2020] [Indexed: 05/21/2023]
Abstract
Household air pollution is the dominant contributor to population air pollutant exposure, but it is often of less concern compared with ambient air pollution. One of the major knowledge gaps in this field are detailed quantitative source contributions of indoor pollutants, especially for gaseous compounds. In this study, temporally, spatially, and vertically resolved monitoring for typical indoor gases including CO2, CO, formaldehyde, methane, and the total volatile organic compounds (VOCs) was conducted to address pollution dynamics and major sources in an urban apartment. The indoor concentrations were significantly higher than the simultaneously measured outdoor concentrations. A new statistic approach was proposed to quantitatively estimate contributions of different sources. It was estimated that outdoor CO2 contributed largely to the indoor CO2, while main indoor sources were human metabolism and cooking. Outdoor infiltration and cooking contributed almost equally to the indoor CO. The contribution of outdoor infiltration to methane was much higher than that to formaldehyde. Cooking contributed to 24%, 19%, and 25% of indoor formaldehyde, methane, and VOCs, whereas the other unresolved indoor sources contributed 61%, 19%, and 35% of these pollutants, respectively. Vertical measurements showed that the uplifting of hot air masses led to relatively high concentrations of the pollutants in the upper layer of the kitchen and in the other rooms to a lesser extent.
Collapse
Affiliation(s)
- Guofeng Shen
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Subinuer Ainiwaer
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Yaqi Zhu
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Shuxiu Zheng
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Weiying Hou
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Huizhong Shen
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, 30332, USA
| | - Yilin Chen
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, 30332, USA
| | - Xilong Wang
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Hefa Cheng
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China
| | - Shu Tao
- College of Urban and Environmental Sciences, Laboratory for Earth Surface Processes, Sino-French Institute for Earth System Science, Peking University, Beijing, 100871, China.
| |
Collapse
|
3
|
Sulewska MJ, Gładyszewska-Fiedoruk K, Sztulc P. Analysis of the results of empirical research and surveys of perceived indoor temperature depending on gender and seasons. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2018; 25:31205-31218. [PMID: 30191526 DOI: 10.1007/s11356-018-3029-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/24/2018] [Accepted: 08/20/2018] [Indexed: 06/08/2023]
Abstract
The indoor thermal condition tests were conducted as real and declared by the respondents. The tests were carried out in the laboratory room in Bialystok. The object is a detached, two-storey building with a cellar. The tests were carried out from February to May 2015. In 1 week, on average, ten measurement series were carried out. During one experiment series, there were between 10 and 15 students present in the room. The aim of the publication is to analyze the results of declared perceived temperature tests in the room depending on the gender, the season and indoor and outdoor temperature conditions. On the basis of statistical analysis of the test results, it was found that in the analyzed age group, the perceived temperature declared in the room is not affected by the respondent's gender. The conclusion is that the temperature sensations of young (and probably healthy) people who do not do physical work are similar, regardless of gender. Differences between the average perceived temperature in the room, declared by all respondents in winter and declared in spring are statistically significant. The indoor perceived temperature declared in the winter is almost constant and does not depend on the temperature of the perceived temperature of outdoor air.
Collapse
Affiliation(s)
- Maria Jolanta Sulewska
- Department of Geotechnics and Structural Mechanics, Bialystok University of Technology, Bialystok, Poland
| | | | - Piotr Sztulc
- Design Studio Jacek Zagórecki, Bialystok, Poland
| |
Collapse
|