1
|
Sharma S, Bennasar M, Yadav M. Evaluation of Fetal Heart Using Fetal Heart Quantification (fetalHQ) Technique in an Indian Cohort. JOURNAL OF CLINICAL ULTRASOUND : JCU 2024. [PMID: 39392047 DOI: 10.1002/jcu.23859] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2024] [Accepted: 09/23/2024] [Indexed: 10/12/2024]
Abstract
OBJECTIVE To evaluate the intra- and interobserver reproducibility of parameters used to determine cardiac morphometry and deformation using FetalHQ in Indian population. METHODOLOGY Two operators blinded to each other performed FetalHQ analysis independently on 35 normal fetuses of gestational age between 18 + 0 and 37 + 0 weeks and days. Intra- and interobserver correlation coefficient and limits of agreement were ascertained for parameters obtained from HQ analysis. RESULTS Excellent reproducibility (ICC > 0.9) was observed for global morphometric parameters. Ejection fraction, stroke volume, stroke volume/kg demonstrated excellent reliability (ICC > 0.9), cardiac output, fractional area change showed a lower correlation (ICC < 0.8), and right and left ventricular global strain showed no correlation. Twenty-four segment sphericity index of left ventricle (LV) and right ventricle (RV) showed low to moderate correlation (LV-ICC 0.48-0.79; RV-ICC 0.43-0.82). Fractional shortening (FS) showed poor intraobserver reliability in RV. CONCLUSION FetalHQ provides reliable estimates of the global cardiac morphometry but not for global cardiac strain. Regional transverse contractility represented by FS has poor correlation in right ventricle, especially in the apical region, possibly due to moderator band. Nevertheless, it is a promising tool which requires technical advancements and validation to improve its accuracy and reliability.
Collapse
Affiliation(s)
| | - Mar Bennasar
- BCNatal-Barcelona Center for Maternal-Fetal and Neonatal Medicine, Hospital Clinicl and Hospital Sant Joan de Deu, Barcelona, Spain
| | | |
Collapse
|
2
|
Zhang M, Kong Y, Huang B, Peng Y, Zhou C, Yan J, Luo Y. Evaluation of the changes in cardiac morphology of fetuses with congenital heart disease using fetalHQ. J Matern Fetal Neonatal Med 2023; 36:2285239. [PMID: 38010356 DOI: 10.1080/14767058.2023.2285239] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2023] [Accepted: 11/14/2023] [Indexed: 11/29/2023]
Abstract
Objective: To evaluate the changes in cardiac morphology of fetuses with congenital heart disease (CHD) using the fetal heart quantitative technique (fetalHQ).Methods: A total of 20 normal pregnant women (control group) and 20 pregnant women suspected of fetal CHD (case group) were included in this study. The dynamic images of the four-chamber view of the fetal heart were recorded and analyzed using fetalHQ. The global sphericity index (GSI) and 24-segment SI of the two groups were compared. The differences in the left and right ventricular 24-segment SI for each group were investigated.Results: There was no statistically significant difference in the GSI between the two groups (p > 0.05). The difference in the SI values of left ventricular segments 1-2 between the case group and control group was statistically significant (all p < 0.05), while the intergroup difference in SI of left ventricular segments 3-24 was not significant (all p > 0.05). The SI of the 24 segments of the right ventricle showed no significant intergroup difference (all p > 0.05). The difference in the left and right ventricular 24-segment SI in the case group did not reach statistical significance (all p > 0.05). In the control group, the SI values between the left and right ventricles were significantly different in segments 18-24 (all p < 0.05), and no significant difference was found in segments 1-17 (all p > 0.05). There was a statistically significant intergroup difference in the percentage of unusual left ventricular SI, determined based on Z-score (p < 0.05), and the percentage of outliers for the right ventricle between the two groups showed no significant difference (p > 0.05).Conclusion: The fetalHQ is regarded as a straightforward and reliable approach for assessing the cardiac GSI and 24-segment SI of left and right ventricles in fetuses diagnosed with CHD. While CHD may not significantly impact the overall shape of the fetal heart or the geometric shape of the right ventricle, in this study, a notable increase in SI values for the left ventricular 1-2 segments was observed, indicating a more flattened ventricular chamber. Additionally, the morphological distinctions between the left and right ventricles in fetuses with CHD are no longer discernible.
Collapse
Affiliation(s)
- Meixiang Zhang
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Yifan Kong
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Beilei Huang
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Yulin Peng
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Cheng Zhou
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Junyi Yan
- Clinical laboratory, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| | - Yingchun Luo
- Department of Ultrasound, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, China
| |
Collapse
|
3
|
Wang Y, Liu H, Hu X, Hu X, Zhang J, Zhang H, Wang J, Su S, Wang Y, Lyu Z. The effect of gestational diabetes mellitus on fetal right heart growth in late-term pregnancy: A prospective study. Echocardiography 2022; 39:1101-1112. [PMID: 35861350 DOI: 10.1111/echo.15425] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 06/12/2022] [Accepted: 07/03/2022] [Indexed: 11/26/2022] Open
Abstract
BACKGROUND Gestational diabetes mellitus (GDM) is a complication of pregnancy strongly associated with an increased risk of structural fetal abnormalities. As the fetal heart grows quickly during the late-term pregnancy period, it is important to understand fetal heart growth before birth. This study explored how GDM affects fetal heart growth by evaluating basic echocardiography indicators during late pregnancy. METHODS This prospective, longitudinal study included 63 GDM patients (GDM group) and 67 healthy pregnant women (control group). All subjects underwent fetal echocardiography scans at gestational weeks 28-32, 32-36, and 36-40. Twelve echocardiographic indicators were assessed at each observation and analyzed by using a mixed model. RESULTS The left atrial diameter (LA) and left ventricular end-diastolic diameter (LV) similarly increased from the first to the third observation. The right ventricular end-diastolic diameter (RV) was significantly different between the groups, and a group × time interaction was detected. The tricuspid annular peak systolic velocity (s') increased more rapidly in the GDM than the control group during the first to second observations, and the group × time interaction was significant. The increase in the tricuspid annular plane systolic excursion (TAPSE) of the GDM group was "slow-fast", while that of the control group was "fast-slow", during three observations. After adjusting covariates, the group difference and interaction effect of TAPSE and RV remained significant. CONCLUSIONS The differences in fetal right heart indicators between the GDM and control groups suggest that GDM may affect the structure and functional growth of the fetal right heart during late-term pregnancy.
Collapse
Affiliation(s)
- Yuhan Wang
- Department of Endocrinology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Hongzhou Liu
- Department of Endocrinology, The First Medical Center, Chinese PLA General Hospital, Beijing, China.,Department of Endocrinology, First Hospital of Handan City, Handan, Hebei Province, China
| | - Xiaona Hu
- Department of Endocrinology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Xiaodong Hu
- Department of Endocrinology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| | - Jiamei Zhang
- Department of Ultrasound Diagnosis, The Second Hospital of Hebei Medical University, Xinhua District, Shijiazhuang, Hebei Province, China
| | - Han Zhang
- Department of Ultrasound Diagnosis, The Second Hospital of Hebei Medical University, Xinhua District, Shijiazhuang, Hebei Province, China
| | - Jincheng Wang
- Department of Radiology, Peking University Cancer Hospital, Haidian District, Beijing, China
| | - Shan Su
- Department of Ultrasound, Chaoyang Hospital, Capital Medical University, Shijingshan District, Beijing, China
| | - Yueheng Wang
- Department of Ultrasound Diagnosis, The Second Hospital of Hebei Medical University, Xinhua District, Shijiazhuang, Hebei Province, China
| | - Zhaohui Lyu
- Department of Endocrinology, The First Medical Center, Chinese PLA General Hospital, Beijing, China
| |
Collapse
|
4
|
Feasibility of 4D-Spatio Temporal Image Correlation (STIC) in the Comprehensive Assessment of the Fetal Heart Using FetalHQ ®. J Clin Med 2022; 11:jcm11051414. [PMID: 35268505 PMCID: PMC8911117 DOI: 10.3390/jcm11051414] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 03/02/2022] [Accepted: 03/02/2022] [Indexed: 02/05/2023] Open
Abstract
Fetal Heart Quantification (FetalHQ®) is a novel speckle tracking software that permits the study of global and regional ventricular shape and function from a 2D four-chamber-view loop. The 4D-Spatio Temporal Image Correlation (STIC) modality enables the offline analysis of optimized and perfectly aligned cardiac planes. We aimed to evaluate the feasibility and reproducibility of 4D-STIC speckle tracking echocardiography (STE) using FetalHQ® and to compare it to 2D STE. We conducted a prospective study including 31 low-risk singleton pregnancies between 20 and 40 weeks of gestation. Four-chamber view volumes and 2D clips were acquired with an apex pointing at 45° and with a frame rate higher than 60 Hz. Morphometric and functional echocardiography was performed by FetalHQ®. Intra- and interobserver reproducibility were evaluated by the intraclass correlation coefficient (ICC). Our results showed excellent reproducibility (ICC > 0.900) for morphometric evaluation (biventricular area, longitudinal and transverse diameters). Reproducibility was also good (ICC > 0.800) for functional evaluation (biventricular strain, Fractional Area Change, left ventricle volumes, ejection fraction and cardiac output). On the contrary, the study of the sphericity index and shortening fraction of the different ventricular segments showed lower reproducibility (ICC < 0.800). To conclude, 4D-STIC is feasible, reproducible and comparable to 2D echocardiography for the assessment of cardiac morphometry and function.
Collapse
|