1
|
Yamamoto M, Yashima F, Shirai S, Tada N, Naganuma T, Yamawaki M, Yamanaka F, Mizutani K, Noguchi M, Ueno H, Takagi K, Ohno Y, Izumo M, Nishina H, Suzuyama H, Yamasaki K, Nishioka K, Hachinohe D, Fuku Y, Otsuka T, Asami M, Watanabe Y, Hayashida K, Ocean-Tavi Investigators OBOT. Performance and outcomes of the SAPIEN 3 Ultra RESILIA transcatheter heart valve in the OCEAN-TAVI registry. EUROINTERVENTION 2024; 20:579-590. [PMID: 38726714 PMCID: PMC11067722 DOI: 10.4244/eij-d-23-00996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Accepted: 01/14/2024] [Indexed: 05/14/2024]
Abstract
BACKGROUND Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.
Collapse
Affiliation(s)
- Masanori Yamamoto
- Department of Cardiology, Toyohashi Heart Center, Toyohashi, Japan
- Department of Cardiology, Nagoya Heart Center, Nagoya, Japan
- Department of Cardiology, Gifu Heart Center, Gifu, Japan
| | - Fumiaki Yashima
- Department of Cardiology, Saiseikai Utsunomiya Hospital, Utsunomiya, Japan
| | - Shinichi Shirai
- Department of Cardiology, Kokura Memorial Hospital, Kitakyushu, Japan
| | - Norio Tada
- Department of Cardiology, Sendai Kosei Hospital, Sendai, Japan
| | - Toru Naganuma
- Department of Cardiology, New Tokyo Hospital, Chiba, Japan
| | - Masahiro Yamawaki
- Department of Cardiology, Saiseikai Yokohama City Eastern Hospital, Yokohama, Japan
| | - Futoshi Yamanaka
- Department of Cardiology, Shonan Kamakura General Hospital, Kamakura, Japan
| | - Kazuki Mizutani
- Department of Medicine, Division of Cardiology, Kindai University, Osaka, Japan
| | - Masahiko Noguchi
- Department of Cardiology, Tokyo Bay Urayasu Ichikawa Medical Center, Urayasu, Japan
| | - Hiroshi Ueno
- Second Department of Internal Medicine, Toyama University Hospital, Toyama, Japan
| | - Kensuke Takagi
- Department of Cardiology, National Cerebral and Cardiovascular Center, Osaka, Japan
| | - Yohei Ohno
- Department of Cardiology, Tokai University School of Medicine, Isehara, Japan
| | - Masaki Izumo
- Department of Cardiology, St Marianna University School of Medicine, Kawasaki, Japan
| | - Hidetaka Nishina
- Department of Cardiology, Tsukuba Medical Center Hospital, Tsukuba, Japan
| | - Hiroto Suzuyama
- Division of Cardiology, Saiseikai Kumamoto Hospital Cardiovascular Center, Kumamoto, Japan
| | - Kazumasa Yamasaki
- Department of Cardiology, Sapporo Higashi Tokushukai Hospital, Sapporo, Japan
| | - Kenji Nishioka
- Department of Cardiology, Hiroshima City Hiroshima Citizens Hospital, Hiroshima, Japan
| | - Daisuke Hachinohe
- Cardiovascular Medicine, Sapporo Heart Center, Sapporo Cardiovascular Clinic, Sapporo, Japan
| | - Yasushi Fuku
- Department of Cardiovascular Medicine, Kurashiki Central Hospital, Kurashiki, Japan
| | - Toshiaki Otsuka
- Department of Hygiene and Public Health, Nippon Medical School, Tokyo, Japan
- Center for Clinical Research, Nippon Medical School Hospital, Tokyo, Japan
| | - Masahiko Asami
- Division of Cardiology, Mitsui Memorial Hospital, Tokyo, Japan
| | - Yusuke Watanabe
- Department of Cardiology, Teikyo University School of Medicine, Tokyo, Japan
| | - Kentaro Hayashida
- Department of Cardiology, Keio University School of Medicine, Tokyo, Japan
| | | |
Collapse
|
2
|
Urena M, Vahanian A, Iung B. Transcatheter Aortic Valve Replacement Without Onsite Cardiac Surgery: A Simplified or Simplistic Approach? JACC Cardiovasc Interv 2023; 16:3031-3033. [PMID: 38151318 DOI: 10.1016/j.jcin.2023.10.038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/01/2023] [Revised: 10/14/2023] [Accepted: 10/17/2023] [Indexed: 12/29/2023]
Affiliation(s)
- Marina Urena
- Department of Cardiology, Bichat Claude Bernard Hospital, Assistance Publique Hôpitaux de Paris, Paris, France; Paris Cité University, Paris, France; INSERM U1148, Paris, France.
| | - Alec Vahanian
- Paris Cité University, Paris, France; INSERM U1148, Paris, France
| | - Bernard Iung
- Department of Cardiology, Bichat Claude Bernard Hospital, Assistance Publique Hôpitaux de Paris, Paris, France; Paris Cité University, Paris, France; INSERM U1148, Paris, France
| |
Collapse
|
3
|
Ahmed A, Mathew DM, Mathew SM, Awad AK, Varghese KS, Khaja S, Vega E, Pandey R, Thomas JJ, Mathew CS, Ahmed S, George J, Awad AK, Fusco PJ. General Anesthesia Versus Local Anesthesia in Patients Undergoing Transcatheter Aortic Valve Replacement: An Updated Meta-Analysis and Systematic Review. J Cardiothorac Vasc Anesth 2023; 37:1358-1367. [PMID: 37120319 DOI: 10.1053/j.jvca.2023.03.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/07/2022] [Revised: 01/07/2023] [Accepted: 03/06/2023] [Indexed: 05/01/2023]
Abstract
OBJECTIVES For patients with aortic stenosis, transcatheter aortic valve replacement (TAVR) offers a less invasive treatment modality than conventional surgical valve replacement. Although the surgery is performed traditionally under general anesthesia (GA), recent studies have described success with TAVR using local anesthesia (LA) and/or conscious sedation. The study authors performed a pairwise meta-analysis to compare the clinical outcomes of TAVR based on operative anesthesia management. DESIGN A random effects pairwise meta-analysis via the Mantel-Haenszel method. SETTING Not applicable, as this is a meta-analysis. PARTICIPANTS No individual patient data were used. INTERVENTIONS Not applicable, as this is a meta-analysis. MEASUREMENTS AND MAIN RESULTS The authors comprehensively searched the PubMed, Embase, and Cochrane databases to identify studies comparing TAVR performed using LA or GA. Outcomes were pooled as risk ratios (RR) or standard mean differences (SMD) and their 95% CIs. The authors' pooled analysis included 14,388 patients from 40 studies (7,754 LA; 6,634 GA). Compared to GA TAVR, LA TAVR was associated with significantly lower rates of 30-day mortality (RR 0.69; p < 0.01) and stroke (RR 0.78; p = 0.02). Additionally, LA TAVR patients had lower rates of 30-day major and/or life-threatening bleeding (RR 0.64; p = 0.01), 30-day major vascular complications (RR 0.76; p = 0.02), and long-term mortality (RR 0.75; p = 0.009). No significant difference was seen between the 2 groups for a 30-day paravalvular leak (RR 0.88, p = 0.12). CONCLUSIONS Transcatheter aortic valve replacement performed using LA is associated with lower rates of adverse clinical outcomes, including 30-day mortality and stroke. No difference was seen between the 2 groups for a 30-day paravalvular leak. These results support the use of minimally invasive forms of TAVR without GA.
Collapse
Affiliation(s)
- Adham Ahmed
- City University of New York School of Medicine, New York, NY.
| | - Dave M Mathew
- City University of New York School of Medicine, New York, NY
| | - Serena M Mathew
- City University of New York School of Medicine, New York, NY
| | - Ahmed K Awad
- Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | | | - Sofia Khaja
- City University of New York School of Medicine, New York, NY
| | - Eamon Vega
- City University of New York School of Medicine, New York, NY
| | - Roshan Pandey
- City University of New York School of Medicine, New York, NY
| | | | | | - Sarah Ahmed
- City University of New York School of Medicine, New York, NY
| | - Jerrin George
- University of Toledo College of Medicine and Life Sciences, Toledo, OH
| | - Ayman K Awad
- Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Peter J Fusco
- City University of New York School of Medicine, New York, NY
| |
Collapse
|
4
|
Update on Minimalist TAVR Care Pathways: Approaches to Care in 2022. Curr Cardiol Rep 2022; 24:1179-1187. [PMID: 35767177 PMCID: PMC9244066 DOI: 10.1007/s11886-022-01737-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 06/03/2022] [Indexed: 11/20/2022]
Abstract
Purpose of Review This review summarizes current data supporting a minimalist TAVR approach and identifies the need for additional study to optimize TAVR care. The authors discuss future directions of the TAVR landscape and how this necessitates evolution of minimalist care pathways. Recent Findings Transcatheter aortic valve replacement (TAVR) has become a mainstay in the treatment of aortic stenosis since the initial procedure in 2002. Recently, attention has shifted to TAVR optimization and the minimalist approach with a focus on minimizing procedural sedation, protocolization of perioperative management, and prioritization on early discharge. This approach has been shown to be safe and reduce procedure time, length of stay, and overall cost for hospital systems. Summary The minimalist care pathway avoids general anesthesia, shortens procedure time and length of stay, and reduces cost without changing mortality or readmission rates at 30 days. A variety of protocols have been proposed without a clear consensus on specific components or patient eligibility. There is a continued need for data regarding patient risk stratification, valve selection, and discharge strategy as TAVR becomes increasingly common.
Collapse
|