1
|
Chapman M, Rajagopal V, Stewart A, Collins DJ. Critical review of single-cell mechanotyping approaches for biomedical applications. LAB ON A CHIP 2024; 24:3036-3063. [PMID: 38804123 DOI: 10.1039/d3lc00978e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Abstract
Accurate mechanical measurements of cells has the potential to improve diagnostics, therapeutics and advance understanding of disease mechanisms, where high-resolution mechanical information can be measured by deforming individual cells. Here we evaluate recently developed techniques for measuring cell-scale stiffness properties; while many such techniques have been developed, much of the work examining single-cell stiffness is impacted by difficulties in standardization and comparability, giving rise to large variations in reported mechanical moduli. We highlight the role of underlying mechanical theories driving this variability, and note opportunities to develop novel mechanotyping devices and theoretical models that facilitate convenient and accurate mechanical characterisation. Moreover, many high-throughput approaches are confounded by factors including cell size, surface friction, natural population heterogeneity and convolution of elastic and viscous contributions to cell deformability. We nevertheless identify key approaches based on deformability cytometry as a promising direction for further development, where both high-throughput and accurate single-cell resolutions can be realized.
Collapse
Affiliation(s)
- Max Chapman
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Vijay Rajagopal
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
| | - Alastair Stewart
- ARC Centre for Personalised Therapeutics Technologies, The University of Melbourne, Parkville, VIC, Australia
- Department of Biochemistry and Pharmacology, The University of Melbourne, Parkville, VIC, Australia
| | - David J Collins
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria, Australia.
- Graeme Clarke Institute University of Melbourne Parkville, Victoria 3052, Australia
| |
Collapse
|
2
|
Manaf NA, Wahab AA, Rasheed HA, Aziz MNC, Salim MIM, Sahalan M, Hum YC, Lai KW. Investigation of single beam ultrasound sensitivity as a monitoring tool for local hyperthermia treatment in breast cancer. MULTIMEDIA TOOLS AND APPLICATIONS 2023; 82:5011-5030. [DOI: 10.1007/s11042-021-11845-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 09/17/2021] [Accepted: 12/23/2021] [Indexed: 09/01/2023]
|
3
|
Miura K, Fukushi Y. Scanning acoustic microscopy imaging of cellular structural and mechanical alterations from external stimuli. Heliyon 2021; 7:e07847. [PMID: 34485733 PMCID: PMC8391065 DOI: 10.1016/j.heliyon.2021.e07847] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 05/17/2021] [Accepted: 08/18/2021] [Indexed: 11/27/2022] Open
Abstract
Cells incur structural and functional damage from external stimuli. Under scanning acoustic microscopy (SAM), speed of sound (SOS), attenuation, and thickness values are plotted to visualize cellular stiffness, viscosity, and size. The obtained digital data are then compared using statistical analysis. In the present study, we aimed to investigate the alterations in the mechanical and structural characteristics of cancer cells in response to anticancer drugs, acidic fluids, and microwave burdens using SAM. We found that active untreated cells showed increased thickness and reduced SOS and attenuation, whereas dying treated cells displayed reduced thickness and increased SOS. Tannic and acetic acid treatments and microwave irradiation all increased SOS and attenuation and reduced thickness, which meant that these treatments made cells thinner, stiffer, and more viscous. Furthermore, the different anticancer drugs interacted with cancer cells to induce characteristic changes in SAM values. These structural and mechanical alterations induced in cells were difficult to observe under light microscopy. However, under SAM, cancer cell activity and function corresponded consistently with changes in SAM values. Cellular damage parameters were statistically compared between the different treatments, and time-dependent cellular changes were established. SAM observation can therefore reliably evaluate cancer cell damage and recovery after chemotherapy and physical therapy. These results may help evaluate the therapeutic efficacy of various treatments.
Collapse
Affiliation(s)
- Katsutoshi Miura
- Department of Health Science, Pathology and Anatomy, Hamamatsu University School of Medicine, Hamamatsu, 431-3192, Japan
| | - Yasuko Fukushi
- Department of Innovative Medical Photonics, Institute for Photonics Research, Preeminent Medical Photonics Education & Research Center, Hamamatsu University School of Medicine, Hamamatsu, 431-3192, Japan
| |
Collapse
|
4
|
Ultrasound-Responsive Smart Drug Delivery System of Lipid Coated Mesoporous Silica Nanoparticles. Pharmaceutics 2021; 13:pharmaceutics13091396. [PMID: 34575472 PMCID: PMC8468042 DOI: 10.3390/pharmaceutics13091396] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2021] [Revised: 08/27/2021] [Accepted: 08/31/2021] [Indexed: 12/23/2022] Open
Abstract
The immediate release of chemotherapeutics at the target site, along with no premature release in circulation is always challenging. The purpose of this study was to develop a stimuli responsive drug delivery system, composed of lipid supported mesoporous silica nanoparticles (MSNPs) for triggered drug release at the target site and simultaneously avoiding the premature release. MSNPs with a higher drug loading capacity and very slow release were designed so as to enhance release by FDA approved US-irradiation. Doxorubicin, as a model drug, and perfluoropentane (PFP) as a US responsive material, were entrapped in the porous structure of MSNPs. Lipid coating enhanced the cellular uptake and in addition provided a gatekeeping effect at the pore opening to reduce premature release. The mechanical and thermal effects of US induced the conversion of liquid PFP to a gaseous form that was able to rupture the lipid layer, resulting in triggered drug release. The prolonged stability profile and non-toxic behavior made them suitable candidate for the delivery of anticancer drugs. This smart system, with the abilities of better cellular uptake and higher cytotoxic effects on US-irradiation, would be a good addition to the applied side of chemotherapeutic advanced drug delivery systems.
Collapse
|
5
|
Moore MJ, Bodera F, Hernandez C, Shirazi N, Abenojar E, Exner AA, Kolios MC. The dance of the nanobubbles: detecting acoustic backscatter from sub-micron bubbles using ultra-high frequency acoustic microscopy. NANOSCALE 2020; 12:21420-21428. [PMID: 33079108 PMCID: PMC7646462 DOI: 10.1039/d0nr05390b] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Nanobubbles have gained attention for their use as highly stable ultrasound (US) contrast agents, but assessment of individual nanobubble size remains a challenge. Current sizing techniques require either extensive sample preparation or depend on assumed values of nanobubble density that are not well characterized. An US based approach would be desirable; however, probing individual nanobubbles using US transducers at clinical frequencies is not feasible due to the comparatively long acoustic wavelengths employed. Here we present a technique which can be used to estimate nano- or microbubble size by virtue of the amount of motion detected in an M-Mode image acquired using an acoustic microscope equipped with a 200 MHz transducer. A sample of a bubble-containing solution is incorporated into a phantom composed of molten agarose. The solidified agarose gel contains pores with well-defined sizes dictated by the agarose concentration. Bubbles in the gel matrix that are smaller in diameter than the gel pore size are capable of undergoing stochastic motion which manifests as intensity fluctuations in M-Mode images. Conversely, bubbles which are larger than the agarose pores become trapped and produce static M-Mode intensity patterns. In this study, agarose gels with concentrations ranging from 0.25% to 1.25% (mean pore sizes ranging from 2.68 μm to 0.34 μm) were loaded with either nanobubbles (mean diameter 0.326 μm) or microbubbles (mean diameter 2.71 μm) and imaged at 200 MHz. In the nanobubble loaded gels, M-Mode fluctuations were clearly visible up to a gel concentration of 1% (pore size of 0.39 μm). In contrast, the microbubble loaded gels exhibited minimal M-Mode fluctuation even at agarose concentrations of 0.25% (2.68 μm pore size). Autocorrelation curves generated from the M-Mode data demonstrated a clear trend of curve flattening (loss of motion) when the pore size was comparable to mean bubble diameter, indicating that individual bubbles trapped in the agarose pores are the main source of acoustic backscatter. In the future, decay parameters extracted from the autocorrelation curves could potentially be used as indicators of mean bubble diameter for bubble populations of unknown size.
Collapse
|
6
|
Matarèse BFE, Lad J, Seymour C, Schofield PN, Mothersill C. Bio-acoustic signaling; exploring the potential of sound as a mediator of low-dose radiation and stress responses in the environment. Int J Radiat Biol 2020; 98:1083-1097. [DOI: 10.1080/09553002.2020.1834162] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Affiliation(s)
- Bruno F. E. Matarèse
- Department of Haematology, University of Cambridge, Cambridge, UK
- Department of Physics, University of Cambridge, Cambridge, UK
| | - Jigar Lad
- Department of Physics and Astronomy, McMaster University, Hamilton, Canada
| | - Colin Seymour
- Department of Biology, McMaster University, Hamilton, Canada
| | - Paul N. Schofield
- Department of Physiology, Development and Neuroscience, University of Cambridge, Cambridge, UK
| | | |
Collapse
|
7
|
Taubenberger AV, Baum B, Matthews HK. The Mechanics of Mitotic Cell Rounding. Front Cell Dev Biol 2020; 8:687. [PMID: 32850812 PMCID: PMC7423972 DOI: 10.3389/fcell.2020.00687] [Citation(s) in RCA: 69] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2020] [Accepted: 07/06/2020] [Indexed: 12/21/2022] Open
Abstract
When animal cells enter mitosis, they round up to become spherical. This shape change is accompanied by changes in mechanical properties. Multiple studies using different measurement methods have revealed that cell surface tension, intracellular pressure and cortical stiffness increase upon entry into mitosis. These cell-scale, biophysical changes are driven by alterations in the composition and architecture of the contractile acto-myosin cortex together with osmotic swelling and enable a mitotic cell to exert force against the environment. When the ability of cells to round is limited, for example by physical confinement, cells suffer severe defects in spindle assembly and cell division. The requirement to push against the environment to create space for spindle formation is especially important for cells dividing in tissues. Here we summarize the evidence and the tools used to show that cells exert rounding forces in mitosis in vitro and in vivo, review the molecular basis for this force generation and discuss its function for ensuring successful cell division in single cells and for cells dividing in normal or diseased tissues.
Collapse
Affiliation(s)
- Anna V. Taubenberger
- Biotechnology Center, Center for Molecular and Cellular Bioengineering, Technische Universität Dresden, Dresden, Germany
| | - Buzz Baum
- MRC Laboratory for Molecular Cell Biology, University College London, London, United Kingdom
| | - Helen K. Matthews
- MRC Laboratory for Molecular Cell Biology, University College London, London, United Kingdom
| |
Collapse
|
8
|
A Macro Lens-Based Optical System Design for Phototherapeutic Instrumentation. SENSORS 2019; 19:s19245427. [PMID: 31835391 PMCID: PMC6960533 DOI: 10.3390/s19245427] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Revised: 12/02/2019] [Accepted: 12/05/2019] [Indexed: 01/07/2023]
Abstract
Light emitting diode (LED) and ultrasound have been powerful treatment stimuli for tumor cell growth due to non-radiation effects. This research is the first preliminary study of tumor cell suppression using a macro-lens-supported 460-nm LED combined with high-frequency ultrasound. The cell density, when exposed to the LED combined with ultrasound, was gradually reduced after 30 min of induction for up to three consecutive days when 48-W DC, 20-cycle, and 50 Vp-p sinusoidal pulses were applied to the LEDs through a designed macro lens and to the ultrasound transducer, respectively. Using a developed macro lens, the non-directional light beam emitted from the LED could be localized to a certain spot, likewise with ultrasound, to avoid additional undesirable thermal effects on the small sized tumor cells. In the experimental results, compared to LED-only induction (14.49 ± 2.73%) and ultrasound-only induction (13.27 ± 2.33%), LED combined with ultrasound induction exhibited the lowest cell density (6.25 ± 1.25%). Therefore, our measurement data demonstrated that a macro-lens-supported 460-nm LED combined with an ultrasound transducer could possibly suppress early stage tumor cells effectively.
Collapse
|
9
|
Ruland A, Gilmore KJ, Daikuara LY, Fay CD, Yue Z, Wallace GG. Quantitative ultrasound imaging of cell-laden hydrogels and printed constructs. Acta Biomater 2019; 91:173-185. [PMID: 31055120 DOI: 10.1016/j.actbio.2019.04.055] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Revised: 04/02/2019] [Accepted: 04/25/2019] [Indexed: 12/17/2022]
Abstract
In the present work we have revisited the application of quantitative ultrasound imaging (QUI) to cellular hydrogels, by using the reference phantom method (RPM) in combination with a local attenuation compensation algorithm. The investigated biological samples consisted of cell-laden collagen hydrogels with PC12 neural cells. These cell-laden hydrogels were used to calibrate the integrated backscattering coefficient (IBC) as a function of cell density, which was then used to generate parametric images of local cell density. The image resolution used for QUI and its impact on the relative IBC error was also investigated. Another important contribution of our work was the monitoring of PC12 cell proliferation. The cell number estimates obtained via the calibrated IBC compared well with data obtained using a conventional quantitative method, the MTS assay. Evaluation of spectral changes as a function of culture time also provided additional information on the cell cluster size, which was found to be in close agreement with that observed by microscopy. Last but not least, we also applied QUI on a 3D printed cellular construct in order to illustrate its capabilities for the evaluation of bioprinted structures. STATEMENT OF SIGNIFICANCE: While there is intensive research in the areas of polymer science, biology, and 3D bio-printing, there exists a gap in available characterisation tools for the non-destructive inspection of biological constructs in the three-dimensional domain, on the macroscopic scale, and with fast data acquisition times. Quantitative ultrasound imaging is a suitable characterization technique for providing essential information on the development of tissue engineered constructs. These results provide a detailed and comprehensive guide on the capabilities and limitations of the technique.
Collapse
|
10
|
Strohm EM, Gnyawali V, Sebastian JA, Ngunjiri R, Moore MJ, Tsai SSH, Kolios MC. Sizing biological cells using a microfluidic acoustic flow cytometer. Sci Rep 2019; 9:4775. [PMID: 30886171 PMCID: PMC6423196 DOI: 10.1038/s41598-019-40895-x] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Accepted: 02/25/2019] [Indexed: 12/19/2022] Open
Abstract
We describe a new technique that combines ultrasound and microfluidics to rapidly size and count cells in a high-throughput and label-free fashion. Using 3D hydrodynamic flow focusing, cells are streamed single file through an ultrasound beam where ultrasound scattering events from each individual cell are acquired. The ultrasound operates at a center frequency of 375 MHz with a wavelength of 4 μm; when the ultrasound wavelength is similar to the size of a scatterer, the power spectra of the backscattered ultrasound waves have distinct features at specific frequencies that are directly related to the cell size. Our approach determines cell sizes through a comparison of these distinct spectral features with established theoretical models. We perform an analysis of two types of cells: acute myeloid leukemia cells, where 2,390 measurements resulted in a mean size of 10.0 ± 1.7 μm, and HT29 colorectal cancer cells, where 1,955 measurements resulted in a mean size of 15.0 ± 2.3 μm. These results and histogram distributions agree very well with those measured from a Coulter Counter Multisizer 4. Our technique is the first to combine ultrasound and microfluidics to determine the cell size with the potential for multi-parameter cellular characterization using fluorescence, light scattering and quantitative photoacoustic techniques.
Collapse
Affiliation(s)
- Eric M Strohm
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Vaskar Gnyawali
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Joseph A Sebastian
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Robert Ngunjiri
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Michael J Moore
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Scott S H Tsai
- Department of Mechanical and Industrial Engineering, Ryerson University, 350 Victoria St, Toronto, Canada
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada
| | - Michael C Kolios
- Department of Physics, Ryerson University, 350 Victoria St, Toronto, Canada.
- Institute for Biomedical Engineering and Science Technology, a partnership between Ryerson University and St. Michael's Hospital, M5B 1W8, Toronto, Canada.
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael's Hospital, M5B 1W8, Toronto, Canada.
| |
Collapse
|
11
|
Wu Y, Stewart AG, Lee PVS. On-chip cell mechanophenotyping using phase modulated surface acoustic wave. BIOMICROFLUIDICS 2019; 13:024107. [PMID: 31065306 PMCID: PMC6478592 DOI: 10.1063/1.5084297] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/06/2018] [Accepted: 04/09/2019] [Indexed: 05/05/2023]
Abstract
A surface acoustic wave (SAW) microfluidic chip was designed to measure the compressibility of cells and to differentiate cell mechanophenotypes. Polystyrene microbeads and poly(methylmethacrylate) (PMMA) microbeads were first tested in order to calibrate and validate the acoustic field. We observed the prefocused microbeads being pushed into the new pressure node upon phase shift. The captured trajectory matched well with the equation describing acoustic radiation force. The compressibility of polystyrene microbeads and that of PMMA microbeads was calculated, respectively, by fitting the trajectory from the experiment and that simulated by the equation across a range of compressibility values. Following, A549 human alveolar basal epithelial cells (A549 cells), human airway smooth muscle (HASM) cells, and MCF-7 breast cancer cells were tested using the same procedure. The compressibility of each cell from the three cell types was measured also by fitting trajectories between the experiment and that from the equation; the size was measured by image analysis. A549 cells were more compressible than HASM and MCF-7 cells; HASM cells could be further distinguished from MCF-7 cells by cell size. In addition, MCF-7 cells were treated by colchicine and 2-methoxyestradiol to disrupt the cell microtubules and were found to be more compressible. Computer simulation was also carried out to investigate the effect of cell compressibility and cell size due to acoustic radiation force to examine the sensitivity of the measurement. The SAW microfluidic method is capable of differentiating cell types or cells under different conditions based on the cell compressibility and the cell size.
Collapse
Affiliation(s)
- Yanqi Wu
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria 3010, Australia
| | - Alastair G. Stewart
- Department of Pharmacology and Therapeutics, University of Melbourne, Melbourne, Victoria 3010, Australia
| | - Peter V. S. Lee
- Department of Biomedical Engineering, University of Melbourne, Melbourne, Victoria 3010, Australia
| |
Collapse
|
12
|
Gnyawali V, Strohm EM, Wang JZ, Tsai SSH, Kolios MC. Simultaneous acoustic and photoacoustic microfluidic flow cytometry for label-free analysis. Sci Rep 2019; 9:1585. [PMID: 30733497 PMCID: PMC6367457 DOI: 10.1038/s41598-018-37771-5] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2018] [Accepted: 12/12/2018] [Indexed: 01/05/2023] Open
Abstract
We developed a label-free microfluidic acoustic flow cytometer (AFC) based on interleaved detection of ultrasound backscatter and photoacoustic waves from individual cells and particles flowing through a microfluidic channel. The AFC uses ultra-high frequency ultrasound, which has a center frequency of 375 MHz, corresponding to a wavelength of 4 μm, and a nanosecondpulsed laser, to detect individual cells. We validate the AFC by using it to count different color polystyrene microparticles and comparing the results to data from fluorescence-activated cell sorting (FACS). We also identify and count red and white blood cells in a blood sample using the AFC, and observe an excellent agreement with results obtained from FACS. This new label-free, non-destructive technique enables rapid and multi-parametric studies of individual cells of a large heterogeneous population using parameters such as ultrasound backscatter, optical absorption, and physical properties, for cell counting and sizing in biomedical and diagnostics applications.
Collapse
Affiliation(s)
- Vaskar Gnyawali
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, Canada
- Keenan Research Centre, St. Michael's Hospital, Toronto, Canada
| | - Eric M Strohm
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
- Translational Biology and Engineering Program, Ted Rogers Centre for Heart Research, Toronto, Canada
| | - Jun-Zhi Wang
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, Canada
- Keenan Research Centre, St. Michael's Hospital, Toronto, Canada
| | - Scott S H Tsai
- Department of Mechanical and Industrial Engineering, Ryerson University, Toronto, Canada
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, Canada
- Keenan Research Centre, St. Michael's Hospital, Toronto, Canada
| | - Michael C Kolios
- Department of Physics, Ryerson University, Toronto, Canada.
- Institute for Biomedical Engineering, Science and Technology (iBEST), Toronto, Canada.
- Keenan Research Centre, St. Michael's Hospital, Toronto, Canada.
| |
Collapse
|
13
|
Choe SW, Park K, Park C, Ryu J, Choi H. Combinational light emitting diode-high frequency focused ultrasound treatment for HeLa cell. Comput Assist Surg (Abingdon) 2017; 22:79-85. [PMID: 28956464 DOI: 10.1080/24699322.2017.1379158] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
PURPOSE Light sources such as laser and light emitting diode or ultrasound devices have been widely used for cancer therapy and regenerative medicines, since they are more cost-effective and less harmful than radiation therapy, chemotherapy or magnetic treatment. Compared to laser and low intensity ultrasound techniques, light emitting diode and high frequency focused ultrasound shows enhanced therapeutic effects, especially for small tumors. MATERIALS AND METHODS We propose combinational light emitting diode-high frequency focused ultrasound treatment for human cervical cancer HeLa cells. Individual red, green, and blue light emitting diode light only, high frequency focused ultrasound only, or light emitting diode light combined with high frequency focused ultrasound treatments were applied in order to characterize the responses of HeLa cells. RESULTS Cell density exposed by blue light emitting diode light combined with high frequency focused ultrasound (2.19 ± 0.58%) was much lower than that of cells exposed by red and green light emitting diode lights (81.71 ± 9.92% and 61.81 ± 4.09%), blue light emitting diode light (11.19 ± 2.51%) or high frequency focused ultrasound only (9.72 ± 1.04%). CONCLUSIONS We believe that the proposed combinational blue light emitting diode-high frequency focused ultrasound treatment could have therapeutic benefits to alleviate cancer cell proliferation.
Collapse
Affiliation(s)
- Se-Woon Choe
- a Department of Medical IT Convergence Engineering , Kumoh National Institute of Technology , Gumi , Korea
| | - Kitae Park
- a Department of Medical IT Convergence Engineering , Kumoh National Institute of Technology , Gumi , Korea
| | - Chulwoo Park
- a Department of Medical IT Convergence Engineering , Kumoh National Institute of Technology , Gumi , Korea
| | - Jaemyung Ryu
- b Department of Optical System Engineering , Kumoh National Institute of Technology , Gumi , Korea
| | - Hojong Choi
- a Department of Medical IT Convergence Engineering , Kumoh National Institute of Technology , Gumi , Korea
| |
Collapse
|
14
|
Veronick JA, Assanah F, Piscopo N, Kutes Y, Vyas V, Nair LS, Huey BD, Khan Y. Mechanically Loading Cell/Hydrogel Constructs with Low-Intensity Pulsed Ultrasound for Bone Repair. Tissue Eng Part A 2017; 24:254-263. [PMID: 28610471 DOI: 10.1089/ten.tea.2016.0547] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Low-intensity pulsed ultrasound (LIPUS) has been shown to be effective for orthopedic fracture repair and nonunion defects, but the specific mechanism behind its efficacy is still unknown. Previously, we have shown a measurable acoustic radiation force at LIPUS intensities traditionally used for clinical treatment and have applied this force to osteoblastic cells encapsulated in type I collagen hydrogels. Our goal in this study is to provide insight and inform the appropriate design of a cell therapy approach to bone repair in which osteoblasts are embedded in collagen hydrogels, implanted into a bony defect, and then transdermally stimulated using LIPUS-derived acoustic radiation force to enhance bone formation at the earliest time points after bone defect repair. To this end, in this study, we demonstrate the ability to measure local hydrogel deformations in response to LIPUS-induced acoustic radiation force and reveal that hydrogel deformation varies with both LIPUS intensity and hydrogel stiffness. Specifically, hydrogel deformation is positively correlated with LIPUS intensity and this deformation is further increased by reducing the stiffness of the hydrogel. We have also shown that encapsulated osteoblastic cells respond to increases in LIPUS intensity by upregulating both cyclooxygenase 2 and prostaglandin E2 (PGE2), both implicated in new bone formation and well-established responses to the application of fluid forces on osteoblast cells. Finally, we demonstrate that combining an increase in LIPUS with a three-dimensional culture environment upregulates both markers beyond their expression noted from either experimental condition alone, suggesting that both LIPUS and hydrogel encapsulation, when combined and modulated appropriately, can enhance osteoblastic response considerably. These studies provide important information toward a clinically relevant cell therapy treatment for bone defects that allows the transdermal application of mechanical loading to bone defects without physically destabilizing the defect site.
Collapse
Affiliation(s)
- James A Veronick
- 1 Department of Biomedical Engineering, University of Connecticut , Storrs, Connecticut
| | - Fayekah Assanah
- 1 Department of Biomedical Engineering, University of Connecticut , Storrs, Connecticut
| | - Nicole Piscopo
- 2 Department of Biomedical Engineering, University of Wisconsin , Madison, Wisconsin
| | - Yasemin Kutes
- 3 Department of Materials Science and Engineering, University of Connecticut , Storrs, Connecticut
| | - Varun Vyas
- 3 Department of Materials Science and Engineering, University of Connecticut , Storrs, Connecticut
| | - Lakshmi S Nair
- 1 Department of Biomedical Engineering, University of Connecticut , Storrs, Connecticut.,3 Department of Materials Science and Engineering, University of Connecticut , Storrs, Connecticut.,4 Department of Orthopaedic Surgery, University of Connecticut Health Center , Farmington, Connecticut.,5 Institute for Regenerative Engineering, University of Connecticut Health Center , Farmington, Connecticut
| | - Bryan D Huey
- 3 Department of Materials Science and Engineering, University of Connecticut , Storrs, Connecticut
| | - Yusuf Khan
- 1 Department of Biomedical Engineering, University of Connecticut , Storrs, Connecticut.,3 Department of Materials Science and Engineering, University of Connecticut , Storrs, Connecticut.,4 Department of Orthopaedic Surgery, University of Connecticut Health Center , Farmington, Connecticut.,5 Institute for Regenerative Engineering, University of Connecticut Health Center , Farmington, Connecticut
| |
Collapse
|
15
|
Abstract
Volume is an essential characteristic of a cell, and this review describes the main methods of its measurement that have been used in the past several decades. The discussed methods include various implementations of light scattering, estimates based on one or two cell dimensions, surface scanning, fluorescence confocal and transmission slice-by-slice imaging, intracellular volume markers, displacement of extracellular solution, quantitative phase imaging, radioactive methods, and some others. Suitability of these methods to some typical samples and applications is discussed. © 2017 International Society for Advancement of Cytometry.
Collapse
Affiliation(s)
- Michael A Model
- Department of Biological Sciences, Kent State University, Kent, Ohio
| |
Collapse
|
16
|
Farhat G, Giles A, Kolios MC, Czarnota GJ. Optical coherence tomography spectral analysis for detecting apoptosis in vitro and in vivo. JOURNAL OF BIOMEDICAL OPTICS 2015; 20:126001. [PMID: 26641199 DOI: 10.1117/1.jbo.20.12.126001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2015] [Accepted: 11/03/2015] [Indexed: 05/16/2023]
Abstract
Apoptosis is a form of programmed cell death characterized by a series of predictable morphological changes at the subcellular level, which modify the light-scattering properties of cells. We present a spectroscopic optical coherence tomography (OCT) technique to detect changes in subcellular morphology related to apoptosis in vitro and in vivo. OCT data were acquired from acute myeloid leukemia (AML) cells treated with cisplatin over a 48-h period. The backscatter spectrum of the OCT signal acquired from the cell samples was characterized by calculating its in vitro integrated backscatter (IB) and spectral slope (SS). The IB increased with treatment duration, while the SS decreased, with the most significant changes occurring after 24 to 48 h of treatment. These changes coincided with striking morphological transformations in the cells and their nuclei. Similar trends in the spectral parameter values were observed in vivo in solid tumors grown from AML cells in mice, which were treated with chemotherapy and radiation. Our results provide a strong foundation from which future experiments may be designed to further understand the effect of cellular morphology and kinetics of apoptosis on the OCT signal and demonstrate the feasibility of using this technique in vivo.
Collapse
Affiliation(s)
- Golnaz Farhat
- University of Toronto, Department of Medical Biophysics, Faculty of Medicine, 2075 Bayview Avenue, Toronto M4N 3M5, CanadabSunnybrook Health Sciences Centre, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto M4N 3M5, CanadacSunnybrook Health Sci
| | - Anoja Giles
- Sunnybrook Health Sciences Centre, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto M4N 3M5, CanadacSunnybrook Health Sciences Centre, Radiation Oncology, 2075 Bayview Avenue, Toronto M4N 3M5, Canada
| | - Michael C Kolios
- Ryerson University, Department of Physics, 350 Victoria Street, Toronto M5B 2K3, Canada
| | - Gregory J Czarnota
- University of Toronto, Department of Medical Biophysics, Faculty of Medicine, 2075 Bayview Avenue, Toronto M4N 3M5, CanadabSunnybrook Health Sciences Centre, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto M4N 3M5, CanadacSunnybrook Health Sci
| |
Collapse
|