1
|
Buwaniwal A, Joshi M, Sharma V, Gupta G, Khan A, Kansal S, Sapra BK. Long term measurements of aerosol mass concentration with optical particle counters: Discrepancies with plausible reasons. CHEMOSPHERE 2024; 363:142949. [PMID: 39067825 DOI: 10.1016/j.chemosphere.2024.142949] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/23/2024] [Revised: 07/23/2024] [Accepted: 07/24/2024] [Indexed: 07/30/2024]
Abstract
Gravimetry-based direct measurements of mass concentration require offline analysis which is not suited for field campaigns. Hence such campaigns rely on the estimation of mass concentration by indirect methods mostly calibrated in controlled laboratory conditions. Optical particle counter (OPC) employs algorithms converting the measured number concentration to mass concentration using appropriate conversion factors. The accuracy of such conversion has not been validated for widely varying atmospheric conditions. This study compares the mass concentration estimated by OPC with those directly obtained from gravimetry-based instruments for outdoor samples collected in Bathinda City, Punjab, India from January 2022 to November 2023. The difference in the gravimetrically measured and OPC predicted values quantified in terms of ratios (gravimetric to optically estimated mass concentration), came out to be 1.42 ± 0.77, 0.99 ± 0.51, and 1.17 ± 0.58 for PM10, PM2.5 and PM1, respectively. This difference when estimated with the back-up filter of OPC itself (C Factor), was 1.37 ± 0.66. More than half of the samples showed ratios outside the 0.8-1.2 range thus indicating under or over-estimation in the OPC predicted values. The probable role of variation in density, shape, and refractive index of atmospheric aerosol particles towards the observed inaccuracy of estimated mass concentration has been highlighted. In the absence of clear guidelines and protocols, the study suggests ways to improve the accuracy via periodic measurement of the C Factor and/or incorporating calibration factors in such measurements.
Collapse
Affiliation(s)
- Ankita Buwaniwal
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Manish Joshi
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India.
| | - Veena Sharma
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Gagan Gupta
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Arshad Khan
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India
| | - Sandeep Kansal
- Department of Physics, Maharaja Ranjit Singh Punjab Technical University, Bathinda, 151001, Punjab, India
| | - Balvinder Kaur Sapra
- Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Mumbai, 400 085, India; Homi Bhabha National Institute, Anushakti Nagar, Mumbai, 400094, India
| |
Collapse
|
2
|
Sepasgozar SME, Blair J. Measuring non-road diesel emissions in the construction industry: a synopsis of the literature. INTERNATIONAL JOURNAL OF CONSTRUCTION MANAGEMENT 2019. [DOI: 10.1080/15623599.2019.1573479] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Affiliation(s)
| | - John Blair
- Faculty of Built Environment, University of New South Wales, Sydney, NSW, Australia
| |
Collapse
|
3
|
A comparison of direct-reading instruments for the measurement of hexavalent chromium during stainless steel welding. ACS CHEMICAL HEALTH & SAFETY 2016. [DOI: 10.1016/j.jchas.2015.10.014] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|