1
|
Watson EL, Patel B, Katsogridakis E, Pepper CJ, Messeder SJ, Saratzis A, Zubair M, Nicholls JK, Chung E, Bown MJ. Selecting Portable Ankle/Toe Brachial Pressure Index Systems for a Peripheral Arterial Disease Population Screening Programme: a Systematic Review, Clinical Evaluation Exercise, and Consensus Process. Eur J Vasc Endovasc Surg 2022; 64:693-702. [PMID: 35970334 DOI: 10.1016/j.ejvs.2022.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Revised: 07/11/2022] [Accepted: 08/03/2022] [Indexed: 01/11/2023]
Abstract
OBJECTIVE To provide an overview of systems available for peripheral arterial disease (PAD) screening, together with respective accuracies and a clinical evaluation to identify a system suitable for use in a community screening programme. METHODS A systematic review of the diagnostic accuracy of six ankle brachial pressure index (ABPI) and toe brachial pressure index (TBPI) devices deemed to be portable, which were Conformité Européenne (CE) marked, and were automated or semi-automated was carried out compared with gold standard handheld Doppler and duplex ultrasound. The devices were MESI-ABPI-MD, Huntleigh Dopplex Ability, Huntleigh ABPI and TBPI systems, Systoe TBPI system, and BlueDop. Seven databases (MEDLINE, EMBASE, Scopus, Web of Science, Cochrane Database of Systematic Reviews, Cochrane Register of Controlled Trials (CENTRAL), and Cumulative Index to Nursing and Allied Health Literature (CINAHL)) were searched, and 11 studies were identified as eligible for review. This was followed by hands on clinical evaluation by abdominal aortic aneurysm (AAA) screening staff (n = 39). During this, devices were demonstrated to staff which they then tested on volunteers and gave feedback using pre-designed questionnaires on their suitability for use in a screening programme. Finally, accuracy data and staff preferences were combined during a consensus conference that was held between study and screening staff to determine the most appropriate device to use in a community screening programme. RESULTS Generally, the evaluated systems have a moderate level of sensitivity and a high level of specificity: Dopplex ability sensitivity 20% - 70%, specificity 86% - 96%; MESI sensitivity 57% - 74%, specificity 85% - 99%; BlueDop sensitivity 95%, specificity 89%; and Systoe sensitivity 71%, specificity 77%. Clinical evaluation by screening staff identified a preference for the MESI system. The consensus conference concluded that the MESI device was a good candidate for use in a community PAD screening programme. CONCLUSION The MESI system is a good candidate to consider for community PAD screening.
Collapse
Affiliation(s)
- Emma L Watson
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Bhavisha Patel
- Vascular Surgery Unit, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Emmanuel Katsogridakis
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK; Vascular Surgery Unit, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Coral J Pepper
- Library and Information Service, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Sarah Jane Messeder
- Vascular Surgery Unit, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Athanasios Saratzis
- Vascular Surgery Unit, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Maria Zubair
- Department of Health Sciences, University of Leicester, Leicester, UK
| | - Jennifer K Nicholls
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK; Library and Information Service, University Hospitals of Leicester NHS Trust, Leicester, UK
| | - Emma Chung
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK
| | - Matthew J Bown
- Department of Cardiovascular Sciences, University of Leicester, Leicester, UK; Vascular Surgery Unit, University Hospitals of Leicester NHS Trust, Leicester, UK; National Institute for Health Research (NIHR), Leicester Biomedical Research Centre, Leicester, UK.
| |
Collapse
|
2
|
Danieluk A, Chlabicz S. Automated Measurements of Ankle-Brachial Index: A Narrative Review. J Clin Med 2021; 10:jcm10215161. [PMID: 34768679 PMCID: PMC8585080 DOI: 10.3390/jcm10215161] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 10/30/2021] [Accepted: 11/01/2021] [Indexed: 12/24/2022] Open
Abstract
Peripheral artery disease (PAD) is an atherosclerotic disease that causes obstruction in lower limb arteries. It increases cardiovascular risk even in asymptomatic patients. Accurate diagnostic tools for identification of affected individuals are needed. Recently, there have been attempts to establish a reliable method of automated ankle-brachial index (ABI) identification. A search of PubMed database to identify studies assessing automatic ABI measurements in agreement with standard PAD diagnosis methods was conducted in December 2020. A total of 57 studies were analyzed in the review. The majority of analyzed studies found ABI measured by automatic oscillometric devices to be potentially feasible for use. Some note that, even though the Doppler and oscillometric methods are not fully interchangeable, the oscillometric devices could be used in screening. Significantly fewer publications are available on automatic plethysmographic devices. For photoplethysmography, most studies reported either good or moderate agreement with reference standards. For air plethysmography, poorer agreement with Doppler ABI is suggested. It is noted that pulse volume recording (PVR) function may improve the diagnostic accuracy of the devices.
Collapse
|
3
|
Casey S, Lanting S, Oldmeadow C, Chuter V. The reliability of the ankle brachial index: a systematic review. J Foot Ankle Res 2019; 12:39. [PMID: 31388357 PMCID: PMC6679535 DOI: 10.1186/s13047-019-0350-1] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/30/2019] [Accepted: 07/29/2019] [Indexed: 11/10/2022] Open
Abstract
Background The ankle brachial index (ABI) is widely used in clinical practice as a non-invasive method to detect the presence and severity of peripheral arterial disease (PAD). Current guidelines suggest that it should be used to monitor potential progression of PAD in affected individuals. As such, it is important that the test is reliable when used for repeated measurements, by the same or different health practitioners. This systematic review aims to examine the literature to evaluate the inter- and intra-rater reliability of the ABI. Methods A systematic search of MEDLINE, EMBASE and CINAHL Complete was conducted to 20 January 2019. Two authors independently reviewed and selected relevant studies and extracted the data. Methodological quality was determined using the Quality Appraisal of Reliability (QAREL) Checklist. Results Fifteen studies of ABI reliability in a range of patient populations were identified as suitable for inclusion in the review: seven considered inter-rater reliability, four intra-rater reliability, and four studies evaluated both inter- and intra-rater reliability. Inter-rater reliability was found to be highly variable, with intraclass correlation coefficients (ICC's) ranging from poor to excellent (ICC 0.42-1.00), while intra-rater also demonstrated considerable variation, with ICCs from 0.42-0.98. Meta-analysis was not possible due to the lack of statistical information reported. Conclusions Results of included studies suggest the inter- and intra-tester reliability of the ABI is acceptable. However, inconsistencies in obtaining systolic pressure measurements, calculating ABI values, and incomplete reporting of methodologies and statistical analysis make it difficult to determine the validity of the results of included studies. Further research, with more consistent reliability methodology, statistical analysis and reporting conducted in populations at risk of PAD is needed to conclusively determine the ABI reliability.
Collapse
|