Martin-Payo R, Fernandez-Alvarez MDM, García-García R, Pérez-Varela Á, Surendran S, Riaño-Galán I. Effectiveness of a hybrid closed-loop system for children and adolescents with type 1 diabetes during physical exercise: A cross-sectional study in real life. An Pediatr (Barc) 2024; 101:183-189. [PMID: 39112134 DOI: 10.1016/j.anpede.2024.07.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 05/22/2024] [Indexed: 09/17/2024] Open
Abstract
OBJECTIVE The aim of the study was to describe how physical exercise affects metabolic control, insulin requirements and carbohydrate intake in children who use hybrid closed-loop systems. METHODS Cross-sectional study design. The sample included 21 children and adolescents diagnosed with type 1 diabetes. During the study, participants were monitored for a period of 7 days to gather comprehensive data on these factors. RESULTS Nine participants (42.9%) had switched to exercise mode to raise the target glucose temporarily to 150 mg/dL. The HbA1c values ranged from 5.5% to 7.9% (median, 6.5%; IQR, 0.75). The percentage of time within the target range of 70-180 mg/dL was similar; however, there was an increased duration of hyperglycaemia and more autocorrections on exercise days. The time spent in severe hyperglycaemia (>250 mg/dL) increased by 2.7% in exercise compared to non-exercise days (P = .02). It is worth noting that hypoglycaemic episodes did not increase during the exercise days compared with non-exercise days. CONCLUSION The hybrid closed-loop system was effective and safe in children and adolescents with type 1 diabetes during the performance of competitive sports in real life.
Collapse
Affiliation(s)
- Ruben Martin-Payo
- Facultad de Medicina y Ciencias de la Salud, Universidad de Oviedo, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain
| | - Maria Del Mar Fernandez-Alvarez
- Facultad de Medicina y Ciencias de la Salud, Universidad de Oviedo, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain.
| | - Rebeca García-García
- Facultad de Medicina y Ciencias de la Salud, Universidad de Oviedo, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain; Endocrinología Pediátrica, Hospital Universitario Central de Asturias, Oviedo, Spain
| | - Ángela Pérez-Varela
- Facultad de Medicina y Ciencias de la Salud, Universidad de Oviedo, Oviedo, Spain
| | - Shelini Surendran
- Departamento de Biociencias, Facultad de Ciencias Médicas y de La Salud, University of Surrey, United Kingdom
| | - Isolina Riaño-Galán
- Facultad de Medicina y Ciencias de la Salud, Universidad de Oviedo, Oviedo, Spain; Instituto de Investigación Sanitaria del Principado de Asturias (ISPA), Oviedo, Spain; Endocrinología Pediátrica, Hospital Universitario Central de Asturias, Oviedo, Spain; Centro de Investigación Biomédica en Red de Epidemiología y Salud Pública (CIBERESP), Madrid, Spain
| |
Collapse
|
2
|
Castillo-Valdez PF, Rodriguez-Salvador M, Ho YS. Scientific Production Dynamics in mHealth for Diabetes: Scientometric Analysis. JMIR Diabetes 2024; 9:e52196. [PMID: 39172508 PMCID: PMC11377915 DOI: 10.2196/52196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2023] [Revised: 03/23/2024] [Accepted: 06/04/2024] [Indexed: 08/23/2024] Open
Abstract
BACKGROUND The widespread use of mobile technologies in health care (mobile health; mHealth) has facilitated disease management, especially for chronic illnesses such as diabetes. mHealth for diabetes is an attractive alternative to reduce costs and overcome geographical and temporal barriers to improve patients' conditions. OBJECTIVE This study aims to reveal the dynamics of scientific publications on mHealth for diabetes to gain insights into who are the most prominent authors, countries, institutions, and journals and what are the most cited documents and current hot spots. METHODS A scientometric analysis based on a competitive technology intelligence methodology was conducted. An innovative 8-step methodology supported by experts was executed considering scientific documents published between 1998 and 2021 in the Science Citation Index Expanded database. Publication language, publication output characteristics, journals, countries and institutions, authors, and most cited and most impactful articles were identified. RESULTS The insights obtained show that a total of 1574 scientific articles were published by 7922 authors from 90 countries, with an average of 15 (SD 38) citations and 6.5 (SD 4.4) authors per article. These documents were published in 491 journals and 92 Web of Science categories. The most productive country was the United States, followed by the United Kingdom, China, Australia, and South Korea, and the top 3 most productive institutions came from the United States, whereas the top 3 most cited articles were published in 2016, 2009, and 2017 and the top 3 most impactful articles were published in 2016 and 2017. CONCLUSIONS This approach provides a comprehensive knowledge panorama of research productivity in mHealth for diabetes, identifying new insights and opportunities for research and development and innovation, including collaboration with other entities, new areas of specialization, and human resource development. The findings obtained are useful for decision-making in policy planning, resource allocation, and identification of research opportunities, benefiting researchers, health professionals, and decision makers in their efforts to make significant contributions to the advancement of diabetes science.
Collapse
|
3
|
Umpierrez GE, Davis GM, ElSayed NA, Fadini GP, Galindo RJ, Hirsch IB, Klonoff DC, McCoy RG, Misra S, Gabbay RA, Bannuru RR, Dhatariya KK. Hyperglycemic Crises in Adults With Diabetes: A Consensus Report. Diabetes Care 2024; 47:1257-1275. [PMID: 39052901 PMCID: PMC11272983 DOI: 10.2337/dci24-0032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 03/29/2024] [Indexed: 07/27/2024]
Abstract
The American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), Joint British Diabetes Societies for Inpatient Care (JBDS), American Association of Clinical Endocrinology (AACE), and Diabetes Technology Society (DTS) convened a panel of internists and diabetologists to update the ADA consensus statement on hyperglycemic crises in adults with diabetes, published in 2001 and last updated in 2009. The objective of this consensus report is to provide up-to-date knowledge about the epidemiology, pathophysiology, clinical presentation, and recommendations for the diagnosis, treatment, and prevention of diabetic ketoacidosis (DKA) and hyperglycemic hyperosmolar state (HHS) in adults. A systematic examination of publications since 2009 informed new recommendations. The target audience is the full spectrum of diabetes health care professionals and individuals with diabetes.
Collapse
Affiliation(s)
- Guillermo E. Umpierrez
- Division of Endocrinology, Metabolism, and Lipids, Department of Medicine, Emory University School of Medicine, Atlanta, GA
| | - Georgia M. Davis
- Division of Endocrinology, Metabolism, and Lipids, Department of Medicine, Emory University School of Medicine, Atlanta, GA
| | - Nuha A. ElSayed
- American Diabetes Association, Arlington, VA
- Department of Medicine, Harvard Medical School, Boston, MA
| | - Gian Paolo Fadini
- Department of Medicine, University of Padua, Padua, Italy
- Veneto Institute of Molecular Medicine, Padua, Italy
| | - Rodolfo J. Galindo
- Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, University of Miami Miller School of Medicine, Miami, FL
| | - Irl B. Hirsch
- Division of Metabolism, Endocrinology, and Nutrition, Department of Medicine, University of Washington, Seattle, WA
| | - David C. Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA
| | - Rozalina G. McCoy
- Division of Endocrinology, Diabetes and Nutrition, Department of Medicine, University of Maryland School of Medicine, Baltimore, MD
- University of Maryland Institute for Health Computing, Bethesda, MD
| | - Shivani Misra
- Division of Metabolism, Digestion & Reproduction, Imperial College London, U.K
- Department of Diabetes & Endocrinology, Imperial College Healthcare NHS Trust, London, U.K
| | - Robert A. Gabbay
- American Diabetes Association, Arlington, VA
- Department of Medicine, Harvard Medical School, Boston, MA
| | | | - Ketan K. Dhatariya
- Elsie Bertram Diabetes Centre, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, U.K
- Department of Medicine, Norwich Medical School, University of East Anglia, Norwich, U.K
| |
Collapse
|
4
|
Umpierrez GE, Davis GM, ElSayed NA, Fadini GP, Galindo RJ, Hirsch IB, Klonoff DC, McCoy RG, Misra S, Gabbay RA, Bannuru RR, Dhatariya KK. Hyperglycaemic crises in adults with diabetes: a consensus report. Diabetologia 2024; 67:1455-1479. [PMID: 38907161 PMCID: PMC11343900 DOI: 10.1007/s00125-024-06183-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/28/2024] [Accepted: 03/29/2024] [Indexed: 06/23/2024]
Abstract
The American Diabetes Association (ADA), European Association for the Study of Diabetes (EASD), Joint British Diabetes Societies for Inpatient Care (JBDS), American Association of Clinical Endocrinology (AACE) and Diabetes Technology Society (DTS) convened a panel of internists and diabetologists to update the ADA consensus statement on hyperglycaemic crises in adults with diabetes, published in 2001 and last updated in 2009. The objective of this consensus report is to provide up-to-date knowledge about the epidemiology, pathophysiology, clinical presentation, and recommendations for the diagnosis, treatment and prevention of diabetic ketoacidosis (DKA) and hyperglycaemic hyperosmolar state (HHS) in adults. A systematic examination of publications since 2009 informed new recommendations. The target audience is the full spectrum of diabetes healthcare professionals and individuals with diabetes.
Collapse
Affiliation(s)
- Guillermo E Umpierrez
- Division of Endocrinology, Metabolism, and Lipids, Department of Medicine, Emory University School of Medicine, Atlanta, GA, USA.
| | - Georgia M Davis
- Division of Endocrinology, Metabolism, and Lipids, Department of Medicine, Emory University School of Medicine, Atlanta, GA, USA
| | - Nuha A ElSayed
- American Diabetes Association, Arlington, VA, USA
- Department of Medicine, Harvard Medical School, Boston, MA, USA
| | - Gian Paolo Fadini
- Department of Medicine, University of Padua, Padua, Italy
- Veneto Institute of Molecular Medicine, Padua, Italy
| | - Rodolfo J Galindo
- Division of Endocrinology, Diabetes and Metabolism, Department of Medicine, University of Miami Miller School of Medicine, Miami, FL, USA
| | - Irl B Hirsch
- Division of Metabolism, Endocrinology, and Nutrition, Department of Medicine, University of Washington, Seattle, WA, USA
| | - David C Klonoff
- Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA, USA
| | - Rozalina G McCoy
- Division of Endocrinology, Diabetes and Nutrition, Department of Medicine, University of Maryland School of Medicine, Baltimore, MD, USA
- University of Maryland Institute for Health Computing, Bethesda, MD, USA
| | - Shivani Misra
- Division of Metabolism, Digestion & Reproduction, Imperial College London, London, UK
- Department of Diabetes & Endocrinology, Imperial College Healthcare NHS Trust, London, UK
| | - Robert A Gabbay
- American Diabetes Association, Arlington, VA, USA
- Department of Medicine, Harvard Medical School, Boston, MA, USA
| | | | - Ketan K Dhatariya
- Elsie Bertram Diabetes Centre, Norfolk and Norwich University Hospitals NHS Foundation Trust, Norwich, UK
- Department of Medicine, Norwich Medical School, University of East Anglia, Norwich, UK
| |
Collapse
|
5
|
Rimon MTI, Hasan MW, Hassan MF, Cesmeci S. Advancements in Insulin Pumps: A Comprehensive Exploration of Insulin Pump Systems, Technologies, and Future Directions. Pharmaceutics 2024; 16:944. [PMID: 39065641 PMCID: PMC11279469 DOI: 10.3390/pharmaceutics16070944] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2024] [Revised: 06/25/2024] [Accepted: 06/27/2024] [Indexed: 07/28/2024] Open
Abstract
Insulin pumps have transformed the way diabetes is managed by providing a more accurate and individualized method of delivering insulin, in contrast to conventional injection routines. This research explores the progression of insulin pumps, following their advancement from initial ideas to advanced contemporary systems. The report proceeds to categorize insulin pumps according to their delivery systems, specifically differentiating between conventional, patch, and implantable pumps. Every category is thoroughly examined, emphasizing its unique characteristics and capabilities. A comparative examination of commercially available pumps is provided to enhance informed decision making. This section provides a thorough analysis of important specifications among various brands and models. Considered factors include basal rate and bolus dosage capabilities, reservoir size, user interface, and compatibility with other diabetes care tools, such as continuous glucose monitoring (CGM) devices and so on. This review seeks to empower healthcare professionals and patients with the essential information to improve diabetes treatment via individualized pump therapy options. It provides a complete assessment of the development, categorization, and full specification comparisons of insulin pumps.
Collapse
Affiliation(s)
| | | | | | - Sevki Cesmeci
- Department of Mechanical Engineering, Georgia Southern University, Statesboro, GA 30458, USA
| |
Collapse
|
6
|
Chen CW, Serata E, Scheub R, Dassau T, Wasserman RM, Anderson BJ, Volkening LK, Laffel LM. Text messaging to enhance glucose monitoring and self-care in teens with type 1 diabetes: Teens' perceptions predict outcomes. Diabetes Res Clin Pract 2024; 212:111719. [PMID: 38789009 DOI: 10.1016/j.diabres.2024.111719] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2024] [Revised: 05/18/2024] [Accepted: 05/20/2024] [Indexed: 05/26/2024]
Abstract
AIMS We assessed association between how teens with type 1 diabetes (T1D) perceived a text-messaging (TM) reminder system to check glucose levels and how their perceptions related to their responsiveness to TM reminders to check glucose levels. METHODS Teens received TM reminders 1-4 times daily to check glucose levels and to reply with the result. Qualitative assessments were performed quarterly. Teens were categorized by perceptions expressed at the majority of the visits and their TM responsiveness over 18 months. RESULTS There were 135 teens (51 % male), with a mean age of 14.8 ± 1.2 years, receiving TM reminders. Distribution of participants' perceptions was 37 % positive (POS), 35 % neutral (with both positive and negative responses (POS/NEG)), and 28 % negative (NEG). Teens with POS perceptions about TM reminders were more likely to respond with a glucose value to the TM reminders than teens with NEG or POS/NEG perceptions (p = 0.002). Youth with POS perceptions and TM responsiveness on ≥ 50 % of days had an 0.81 % improvement in their HbA1c (p = 0.004) over 18 months. CONCLUSIONS Teens with POS perceptions to TM reminders were likely to respond and their responsiveness yielded glycemic benefit, suggesting need to consider opinions of teens with T1D to maximize their intervention engagement and resulting benefits.
Collapse
Affiliation(s)
- Charlotte W Chen
- The Children's Hospital at Montefiore, Albert Einstein College of Medicine, Bronx, NY, USA
| | - Emily Serata
- Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
| | - Rachel Scheub
- Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
| | - Tal Dassau
- Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA
| | | | | | | | - Lori M Laffel
- Joslin Diabetes Center, Harvard Medical School, Boston, MA, USA.
| |
Collapse
|
7
|
Castañeda J, Arrieta A, van den Heuvel T, Battelino T, Cohen O. Time in Tight Glucose Range in Type 1 Diabetes: Predictive Factors and Achievable Targets in Real-World Users of the MiniMed 780G System. Diabetes Care 2024; 47:790-797. [PMID: 38113453 PMCID: PMC11043222 DOI: 10.2337/dc23-1581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Accepted: 11/13/2023] [Indexed: 12/21/2023]
Abstract
OBJECTIVE We studied time in tight range (TITR) (70-140 mg/dL) in real-world users of the MiniMed 780G system (MM780G). RESEARCH DESIGN AND METHODS CareLink Personal data were extracted (August 2020 to December 2022) to examine TITR and its relationship with time in range (TIR; 70-180 mg/dL), factors predicting higher TITR, and which TITR target is a reasonable treatment goal. RESULTS The 13,461 users (3,762 age ≤15 years and 9,699 age >15 years) showed an average TITR of 48.9% in those age ≤15 years and 48.8% in the older group (vs. TIR 71.2% and 73.9%, respectively). Consistent use of a glucose target (GT) of 100 mg/dL and active insulin time (AIT) of 2 h were the most relevant factors predicting higher TITR (P < 0.0001). In users consistently applying these optimal settings, TITR was 56.7% in those age ≤15 years and 57.0% in the older group, and the relative impact of these settings on TITR was 60% and 86% greater than that on TIR, respectively. TITRs of ∼45% (age ≤15 years 46.3% and older group 45.4%), ∼50% (50.7% and 50.7%) and ∼55% (56.4% and 58.0%) were best associated with glucose management indicators <7.0%, <6.8%, and <6.5%, respectively. TITRs of >45%, >50%, and >55% were achieved in 91%, 74%, and 55% of those age ≤15 years and 93%, 81%, and 57% of older group users, respectively, at optimal settings. CONCLUSIONS This study demonstrates that 1) mean TIR is high with a high mean TITR in MM780G users (>48%), 2) consistent use of optimal GT/AIT improves TITR (>56%), 3) the impact of these settings on TITR is larger than on TIR, and 4) a TITR target >50% is our suggested treatment goal.
Collapse
Affiliation(s)
| | - Arcelia Arrieta
- Medtronic International Trading Sàrl, Tolochenaz, Switzerland
| | | | - Tadej Battelino
- University Medical Centre Ljubljana, Ljubljana, Slovenia
- Faculty of Medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Ohad Cohen
- Medtronic International Trading Sàrl, Tolochenaz, Switzerland
| |
Collapse
|
8
|
Abraham MB, Smith GJ, Dart J, Davis EA, Jones TW. Clinical Outcomes with MiniMed TM 780G Advanced Hybrid Closed-Loop Therapy in 2- to 6-Year-Old Children with Type 1 Diabetes. Diabetes Technol Ther 2024; 26:341-345. [PMID: 38215208 DOI: 10.1089/dia.2023.0508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/14/2024]
Abstract
Advanced hybrid closed-loop (AHCL) therapy with the Medtronic MiniMed™ 780G system improves glycemia; however, the clinical outcomes in younger children remain less established. This pilot study aimed to explore the continuous glucose monitoring (CGM) metrics in very young children on AHCL. Children between 2 and 7 years of age and on insulin pump therapy were recruited. A 2-week phase in manual mode was followed by a 6-week AHCL phase. CGM metrics were analyzed to review glycemic outcomes. Out of 11 participants enrolled [mean (standard deviation [SD]) age 5.3 (0.8) years], 10 completed the study. Time in closed loop was 96.7 (3.9)%. In AHCL, participants had a mean (SD) time in range of 72.6 (7.4)% and spent 3.0 (1.74)% and 0.63 (0.46)% in time <70 and <54 mg/dL, respectively. AHCL is a feasible option for management of young children with type 1 diabetes.
Collapse
Affiliation(s)
- Mary B Abraham
- Children's Diabetes Centre, Telethon Kids Institute, The University of Western Australia, Perth, Australia
- Department of Endocrinology and Diabetes, Perth Children's Hospital, Perth, Australia
- Centre for Child Health Research, The University of Western Australia, Perth, Australia
| | - Grant J Smith
- Children's Diabetes Centre, Telethon Kids Institute, The University of Western Australia, Perth, Australia
| | - Julie Dart
- Children's Diabetes Centre, Telethon Kids Institute, The University of Western Australia, Perth, Australia
- Department of Endocrinology and Diabetes, Perth Children's Hospital, Perth, Australia
| | - Elizabeth A Davis
- Children's Diabetes Centre, Telethon Kids Institute, The University of Western Australia, Perth, Australia
- Department of Endocrinology and Diabetes, Perth Children's Hospital, Perth, Australia
- Discipline of Paediatrics, Medical School, The University of Western Australia, Perth, Australia
| | - Timothy W Jones
- Children's Diabetes Centre, Telethon Kids Institute, The University of Western Australia, Perth, Australia
- Department of Endocrinology and Diabetes, Perth Children's Hospital, Perth, Australia
- Discipline of Paediatrics, Medical School, The University of Western Australia, Perth, Australia
| |
Collapse
|
9
|
Singh R, Imberg H, Ahmadi SS, Hallström S, Jendle J, Tengmark BO, Folino A, Marie E, Lind M. Effects, Safety, and Treatment Experience of Advanced Hybrid Closed-Loop Systems in Clinical Practice Among Adults Living With Type 1 Diabetes. J Diabetes Sci Technol 2024:19322968241242386. [PMID: 38629871 DOI: 10.1177/19322968241242386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 04/28/2024]
Abstract
BACKGROUND There are few studies providing a more comprehensive picture of advanced hybrid closed-loop (AHCL) systems in clinical practice. The aim was to evaluate the effects of the AHCL systems, Tandem® t: slim X2™ with Control IQ™, and MiniMed™ 780G, on glucose control, safety, treatment satisfaction, and practical barriers for individuals with type 1 diabetes. METHOD One hundred forty-two randomly selected adults with type 1 diabetes at six diabetes outpatient clinics in Sweden at any time treated with either the Tandem Control IQ (TCIQ) or the MiniMed 780G system were included. Glycated hemoglobin A1c (HbA1c) and glucose metrics were evaluated. Treatment satisfaction and practical barriers were examined via questionnaires. RESULTS Mean age was 42 years, median follow-up was 1.7 years, 58 (40.8%) were females, 65% used the TCIQ system. Glycated hemoglobin A1c was reduced by 0.6% (6.8 mmol/mol; 95% confidence interval [CI] = 0.5-0.8% [5.3-8.2 mmol/mol]; P < .001), from 7.3% to 6.7% (57-50 mmol/mol). Time in range (TIR) increased with 14.5% from 57.0% to 71.5% (95% CI = 12.2%-16.9%; P < .001). Time below range (TBR) (<70 mg/dL, <3.9 mmol/L) decreased from 3.8% to 1.6% (P < .001). The standard deviation of glucose values was reduced from 61 to 51 mg/dL (3.4-2.9 mmol/L, P < .001) and the coefficient of variation from 35% to 33% (P < .001). Treatment satisfaction increased, score 14.8 on the Diabetes Treatment Satisfaction Questionnaire (DTSQ) (change version ranging from -18 to 18, P < .001). Four severe hypoglycemia events were detected and no cases of ketoacidosis. Skin problems were experienced by 32.4% of the study population. CONCLUSIONS Advanced hybrid closed-loop systems improve glucose control with a reasonable safety profile and high treatment satisfaction. Skin problems are common adverse events.
Collapse
Affiliation(s)
- Ramanjit Singh
- Department of Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Molecular and Clinical Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Henrik Imberg
- Department of Molecular and Clinical Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Mathematical Sciences, Chalmers University of Technology and University of Gothenburg, Gothenburg, Sweden
- Statistiska Konsultgruppen, Gothenburg, Sweden
| | - Shilan Seyed Ahmadi
- Department of Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Molecular and Clinical Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Sara Hallström
- Department of Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Molecular and Clinical Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Johan Jendle
- Faculty of Medicine and Health, School of Medical Science, Örebro University, Örebro, Sweden
| | | | - Anna Folino
- Department of Medicine and Emergency, Sahlgrenska University Hospital/Mölndal Hospital, Gothenburg, Sweden
| | - Ekström Marie
- Department of Medicine, NU Hospital Group, Uddevalla, Sweden
| | - Marcus Lind
- Department of Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
- Department of Molecular and Clinical Medicine, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
- Department of Medicine, NU Hospital Group, Uddevalla, Sweden
| |
Collapse
|
10
|
Beato-Víbora PI, Chico A, Moreno-Fernandez J, Bellido-Castañeda V, Nattero-Chávez L, Picón-César MJ, Martínez-Brocca MA, Giménez-Álvarez M, Aguilera-Hurtado E, Climent-Biescas E, Azriel-Mir S, Rebollo-Román Á, Yoldi-Vergara C, Pazos-Couselo M, Alonso-Carril N, Quirós C. A Multicenter Prospective Evaluation of the Benefits of Two Advanced Hybrid Closed-Loop Systems in Glucose Control and Patient-Reported Outcomes in a Real-world Setting. Diabetes Care 2024; 47:216-224. [PMID: 37948469 PMCID: PMC11387664 DOI: 10.2337/dc23-1355] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/25/2023] [Accepted: 10/22/2023] [Indexed: 11/12/2023]
Abstract
OBJECTIVE Advanced hybrid closed-loop systems (AHCL) have been shown to improve glycemic control and patient-reported outcomes in type 1 diabetes. The aim was to analyze the outcomes of two commercially available AHCL in real life. RESEARCH DESIGN AND METHODS A prospective study was performed, including adolescents and adults with type 1 diabetes, AHCL naïve, from 14 centers, who initiated the use of MM780G with SmartGuard or Tandem t:slimX2 with Control-IQ. Baseline and 3-month evaluations were performed, assessing HbA1c, time in different glycemic ranges, and patient-reported outcomes. The primary outcome was the between-group time in range 70-180 mg/dL difference from beginning to end of follow-up. RESULTS One hundred fifty participants were included, with 75 initiating each system (age: 39.9 ± 11.4 years [16-72]; 64% female; diabetes duration: 21.6 ± 11.9 years). Time in range increased from 61.53 ± 14.01% to 76.17 ± 9.48% (P < 0.001), with no between-group differences (P = 0.591). HbA1c decreased by 0.56% (95% CI 0.44%, 0.68%) (6 mmol/mol, 95% CI 5, 7) (P < 0.001), from 7.43 ± 1.07% to 6.88 ± 0.60% (58 ± 12 to 52 ± 7 mmol/mol) in the MM780G group, and from 7.14 ± 0.70% to 6.56 ± 0.53% (55 ± 8 to 48 ± 6 mmol/mol) in the Control-IQ group (both P < 0.001 to baseline, P = 0.819 between groups). No superiority of one AHCL over the other regarding fear of hypoglycemia or quality of life was found. Improvement in diabetes-related distress was higher in Control-IQ users (P = 0.012). Sleep quality was improved (PSQI: from 6.94 ± 4.06 to 6.06 ± 4.05, P = 0.004), without differences between systems. Experience with AHCL, evaluated by the INSPIRE measures, exceeded the expectations. CONCLUSIONS The two AHCL provide significant improvement in glucose control and satisfaction, with no superiority of one AHCL over the other.
Collapse
Affiliation(s)
| | - Ana Chico
- Hospital Santa Creu i Sant Pau, Barcelona, Spain
| | | | | | | | | | | | | | | | | | | | | | | | | | | | - Carmen Quirós
- Hospital Universitari Mutua de Terrassa, Barcelona, Spain
| |
Collapse
|
11
|
Seget S, Chobot A, Rusak E, Ochab A, Bielawska A, Polanska J, Jarosz-Chobot P. MiniMed 780GTM in children with type 1 diabetes under seven years of age: Prospective open-label, single-arm, double-center, follow-up study. Technol Health Care 2024; 32:1463-1472. [PMID: 37781828 DOI: 10.3233/thc-230490] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/03/2023]
Abstract
BACKGROUND Given the steadily rising incidence of type 1 diabetes (T1D), particularly among the youngest preschool children, coupled with well-documented challenges of achieving and maintaining optimal metabolic control in this age group, there is a growing need for advanced technological devices. OBJECTIVE To evaluate glycaemic control in children below the age of seven with type 1 diabetes (T1D) and assess the safety of the advanced hybrid closed loop (AHCL) system in comparison to the previous treatment method, a sensor-augmented pump with predictive low-glucose suspend (SAP-PLGS). METHOD Data from 10 children (aged 2.60-6.98 years) with T1D who transitioned to the AHCL system from SAP-PLGS were analysed. SAP-PLGS records from two weeks prior to the initiation of AHCL were compared with records from the initial four weeks post-switch (excluding the training period). These data were examined at two 2-week intervals and compared with records from two weeks post six-month usage of the AHCL. RESULTS A significant decrease in the average nighttime glucose concentration was observed compared to pre-AHCL values (p= 0.001, concordance W = 0.53). The Glucose Management Indicator (GMI) value significantly decreased from 6.88 ± 0.37% to 6.52 ± 0.32% (p= 0.018, rbc = 0.93) immediately following the device switch and stabilized at 6.50 ± 0.28% (p= 0.001, W = 0.53) and 6.55 ± 0.41% (p= 0.001, W = 0.53) at subsequent stages of the study. An improvement was also observed in mean glucose values for time spent < 54 mg/dl, while the proportion of time within this range was maintained, both during the day (p< 0.001, W = 0.58) and at night (p= 0.002, W = 0.83). CONCLUSION The AHCL MiniMed 780GTM system improved glycaemic control in the studied group of children under seven years of age with T1D compared to previous SAP-PLGS therapy. It proved to be safe for delivering insulin in this age group.
Collapse
Affiliation(s)
- Sebastian Seget
- Department of Children's Diabetology, Medical University of Silesia, Katowice, Poland
| | - Agata Chobot
- Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland
| | - Ewa Rusak
- Department of Children's Diabetology, Medical University of Silesia, Katowice, Poland
| | - Agnieszka Ochab
- Department of Pediatrics, Institute of Medical Sciences, University of Opole, Opole, Poland
| | - Anna Bielawska
- Department of Children's Diabetology, Medical University of Silesia, Katowice, Poland
| | - Joanna Polanska
- Department of Data Science and Engineering, Silesian University of Technology, Gliwice, Poland
| | | |
Collapse
|
12
|
Zimmer RT, Auth A, Schierbauer J, Haupt S, Wachsmuth N, Zimmermann P, Voit T, Battelino T, Sourij H, Moser O. (Hybrid) Closed-Loop Systems: From Announced to Unannounced Exercise. Diabetes Technol Ther 2023. [PMID: 38133645 DOI: 10.1089/dia.2023.0293] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/23/2023]
Abstract
Physical activity and exercise have many beneficial effects on general and type 1 diabetes (T1D) specific health and are recommended for individuals with T1D. Despite these health benefits, many people with T1D still avoid exercise since glycemic management during physical activity poses substantial glycemic and psychological challenges - which hold particularly true for unannounced exercise when using an AID system. Automated insulin delivery (AID) systems have demonstrated their efficacy in improving overall glycemia and in managing announced exercise in numerous studies. They are proven to increase time in range (70-180 mg/dL) and can especially counteract nocturnal hypoglycemia, even when evening exercise was performed. AID-systems consist of a pump administering insulin as well as a CGM sensor (plus transmitter), both communicating with a control algorithm integrated into a device (insulin pump, mobile phone/smart watch). Nevertheless, without manual pre-exercise adaptions, these systems still face a significant challenge around physical activity. Automatically adapting to the rapidly changing insulin requirements during unannounced exercise and physical activity is still the Achilles' heel of current AID systems. There is an urgent need for improving current AID-systems to safely and automatically maintain glucose management without causing derailments - so that going forward, exercise announcements will not be necessary in the future. Therefore, this narrative literature review aimed to discuss technological strategies to how current AID-systems can be improved in the future and become more proficient in overcoming the hurdle of unannounced exercise. For this purpose, the current state-of-the-art therapy recommendations for AID and exercise as well as novel research approaches are presented along with potential future solutions - in order to rectify their deficiencies in the endeavor to achieve fully automated AID-systems even around unannounced exercise.
Collapse
Affiliation(s)
- Rebecca Tanja Zimmer
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Alexander Auth
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Janis Schierbauer
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Sandra Haupt
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Nadine Wachsmuth
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Paul Zimmermann
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Thomas Voit
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Bayreuth, Bavaria, Germany;
| | - Tadej Battelino
- University Children's Hospital, Ljubljana, Slovenia, Department of Endocrinology, Diabetes and Metabolism, Bohoriceva 20, Ljubljana, Slovenia, 1000
- Slovenia;
| | - Harald Sourij
- Medical University of Graz, 31475, Auenbruggerplatz 15, 8036 Graz, Graz, Austria, 8036;
| | - Othmar Moser
- University of Bayreuth, 26523, Division Exercise Physiology and Metabolism Institute of Sport Science, Universitätsstraße 30, Bayreuth, Bayern, Germany, 95440;
| |
Collapse
|
13
|
Gómez Medina AM, Henao Carrillo DC, Silva León JD, Gómez González JA, Muñoz Velandia OM, Conde Brahim L, Mecón Prada GA, Rondón Sepúlveda M. Results From a Virtual Clinic for the Follow-up of Patients Using the Advanced Hybrid Closed-Loop System. J Diabetes Sci Technol 2023:19322968231204376. [PMID: 37942633 DOI: 10.1177/19322968231204376] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
BACKGROUND Evidence regarding the implementation of medium-term strategies in advanced hybrid closed-loop (AHCL) system users is limited. Therefore, this study aimed to describe the efficacy and safety of the AHCL system in patients with type 1 diabetes (T1D) on a six-month follow-up in a virtual diabetes clinic (VDC). METHOD A prospective cohort of adult patients with T1D treated using the AHCL system (Mini Med 780G; Medtronic, Northridge, California) in a VDC follow-up. Standardized training and follow-up were conducted virtually. Clinical data and metabolic control outcomes were reported at baseline, and at three and six months. RESULTS Sixty-four patients (mean age = 42 ± 14.6 years, 65% men, 54% with graduate education) were included. Percentage time in range (%TIR) increased significantly regardless of prior therapy with intermittently scanned continuous glucose monitoring + multiple daily injections and sensor-augmented pump therapy with predictive low-glucose management after starting AHCL and persisted during the follow-up period with no hypoglycemic events. The %TIR 70 to 180 mg/dL according to socioeconomic strata was 73.4% ± 5.3%, 78.1% ± 8.1%, and 84.2% ± 7.5% for the lower, middle, and upper strata, respectively. The sensor was used more frequently in the population with a higher education level. Adherence to sensor use and SmartGuard retention were higher in patients who underwent the VDC follow-up. CONCLUSIONS Medium-term follow-up of users of AHCL systems in a VDC contributes to safely achieving %TIR goals. Virtual diabetes clinic follow-up favored adherence to sensor use and continuous SmartGuard use. Socioeconomic strata were associated with a better glycemic profile and education level was associated with better adherence to sensor use.
Collapse
Affiliation(s)
- Ana María Gómez Medina
- Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia
| | | | - Julio David Silva León
- Endocrinology Unit, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia
| | | | - Oscar Mauricio Muñoz Velandia
- Department of Internal Medicine, Hospital Universitario San Ignacio, Pontificia Universidad Javeriana, Bogotá, Colombia
| | | | | | - Martin Rondón Sepúlveda
- Department of Clinical Epidemiology and Biostatistics, Pontificia Universidad Javeriana, Bogotá, Colombia
| |
Collapse
|
14
|
Elbarbary NS, Ismail EAR. MiniMed 780G™ advanced hybrid closed-loop system performance in Egyptian patients with type 1 diabetes across different age groups: evidence from real-world users. Diabetol Metab Syndr 2023; 15:205. [PMID: 37845757 PMCID: PMC10580510 DOI: 10.1186/s13098-023-01184-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 10/08/2023] [Indexed: 10/18/2023] Open
Abstract
BACKGROUND Advanced hybrid closed loop (AHCL) system provides both automated basal rate and correction boluses to keep glycemic values in a target range. OBJECTIVES To evaluate the real-world performance of the MiniMed™ 780G system among different age groups of Egyptian patients with type 1diabetes. METHODS One-hundred seven AHCL system users aged from 3 to 71 years were enrolled. Data uploaded by patients were aggregated and analyzed. The mean glucose management indicator (GMI), percentage of time spent within glycemic ranges (TIR), time below range (TBR) and time above range (TAR) were determined. RESULTS Six months after initiating Auto Mode, patients spent a mean of 85.31 ± 22.04% of the time in Auto Mode (SmartGuard) and achieved a mean GMI of 6.95 ± 0.58% compared with 7.9 ± 2.1% before AHCL initiation (p < 0.001). TIR 70-180 mg/dL was increased post-AHCL initiation from 63.48 ± 10.14% to 81.54 ± 8.43% (p < 0.001) while TAR 180-250 mg/dL, TAR > 250 mg/dL, TBR < 70 mg/dL and TBR < 54 mg/dL were significantly decreased (p < 0.001). After initiating AHCL, TIR was greater in children and adults compared with adolescents (82.29 ± 7.22% and 83.86 ± 9.24% versus 78.4 ± 7.34%, respectively; p < 0.05). The total daily dose of insulin was increased in all age groups primarily due to increased system-initiated insulin delivery including auto correction boluses and basal insulin. CONCLUSIONS MiniMed™ 780G system users across different age groups achieved international consensus-recommended glycemic control with no serious adverse effects even in challenging age group as children and adolescents.
Collapse
Affiliation(s)
- Nancy Samir Elbarbary
- Department of Pediatrics, Faculty of medicine, Ain shams University, 25 Ahmed Fuad St. Saint Fatima, Cairo, 11361, Egypt.
| | | |
Collapse
|
15
|
Rachmiel M, Lebenthal Y, Mazor-Aronovitch K, Brener A, Levek N, Jacobi-Polishook T, Ben Ari T, Abiri S, Landau Z, Pinhas-Hamiel O. MiniMed 780G Advanced Hybrid Closed-Loop System Outcomes According to Pubertal Status: Awesome Study Group Real-Life Experience. Diabetes Technol Ther 2023; 25:643-651. [PMID: 37219952 DOI: 10.1089/dia.2023.0081] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Background and Aims: Achieving good glycemic control is a major challenge for adolescents with type 1 diabetes (TID). The introduction of the MiniMed 780G system, an advanced hybrid closed-loop (AHCL) that enables an automatic correction of insulin, gave hope for improved glycemic outcomes in adolescents. We assessed specific characteristics associated with glycemic measures in youth with T1D switching to Minimed 780G. Methods: This retrospective observational real-life multicenter study from the AWeSoMe Group assessed continuous glucose monitoring (CGM) metrics of 22 patients (59% females, median age 13.9 interquartile range [IQR 11,18] years), from a high socioeconomic background. CGM metrics were recorded for 2-week periods before AHCL, after 1, 3, 6 months, and at the end of follow-up (median 10.9 [IQR 5.4, 17.4] months). Delta-variables (Δ) were calculated as the difference between the end of follow-up and baseline. Results: Time in range (TIR)70-180mg/dL increased from 65% [52, 72] to 75% [63, 80], P = 0.008, from baseline to end of follow-up. Time above range>180mg/dL decreased from 28% [20, 46] to 22% [14, 35], P = 0.047. Advanced pubertal stage was correlated with less improvement in ΔTAR>180mg/dL, r = 0.47, P = 0.05, and less CGM usage r = -0.57, P = 0.05. A longer disease duration was associated with less improvement in ΔTAR180-250mg/dL, r = 0.48, P = 0.05. Lower pump site change frequency was associated with higher glucose management indicator, r = 0.5, P = 0.03, and lower TIR70-180mg/dL r = -0.52, P = 0.08. Conclusion: The use of AHCL enabled improvements in TIR70-180mg/dL in youth with T1D. More advanced pubertal stages, longer disease duration, and less compliance were associated with less improvement, stressing the need for continuous support, and re-education in this age group.
Collapse
Affiliation(s)
- Marianna Rachmiel
- Pediatric Endocrinology Unit, Shamir (Assaf Harofeh) Medical Center, Beer Yaakov, Israel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
| | - Yael Lebenthal
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Pediatric Endocrinology and Diabetes Unit, Dana-Dwek Children's Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Kineret Mazor-Aronovitch
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- National Juvenile Diabetes Center, Maccabi Health Care Services, Ra'anana, Israel
- Pediatric Endocrine and Diabetes Unit, Edmond and Lily Safra Children's Hospital, Chaim Sheba Medical Center, Ramat-Gan, Israel
| | - Avivit Brener
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Pediatric Endocrinology and Diabetes Unit, Dana-Dwek Children's Hospital, Tel Aviv Sourasky Medical Center, Tel Aviv, Israel
| | - Noah Levek
- National Juvenile Diabetes Center, Maccabi Health Care Services, Ra'anana, Israel
- Pediatric Endocrine and Diabetes Unit, Edmond and Lily Safra Children's Hospital, Chaim Sheba Medical Center, Ramat-Gan, Israel
| | - Talia Jacobi-Polishook
- Pediatric Endocrinology Unit, Shamir (Assaf Harofeh) Medical Center, Beer Yaakov, Israel
| | - Tal Ben Ari
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Pediatric Endocrine and Diabetes Unit, E. Wolfson Medical Center, Holon, Israel
| | - Shirli Abiri
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- Pediatric Endocrine and Diabetes Unit, E. Wolfson Medical Center, Holon, Israel
| | - Zohar Landau
- National Juvenile Diabetes Center, Maccabi Health Care Services, Ra'anana, Israel
- Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - Orit Pinhas-Hamiel
- Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel
- National Juvenile Diabetes Center, Maccabi Health Care Services, Ra'anana, Israel
- Pediatric Endocrine and Diabetes Unit, Edmond and Lily Safra Children's Hospital, Chaim Sheba Medical Center, Ramat-Gan, Israel
| |
Collapse
|
16
|
Lendínez‐Jurado A, Gómez‐Perea A, Ariza‐Jiménez AB, Tapia‐Ceballos L, Becerra‐Paz I, Martos‐Lirio MF, Moreno‐Jabato F, Leiva‐Gea I. Impact on glucometric variables and quality of life of the advanced hybrid closed-loop system in pediatric and adolescent type 1 diabetes. J Diabetes 2023; 15:699-708. [PMID: 37337407 PMCID: PMC10415871 DOI: 10.1111/1753-0407.13426] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/28/2022] [Revised: 04/17/2023] [Accepted: 05/16/2023] [Indexed: 06/21/2023] Open
Abstract
BACKGROUND In recent years, technological advances in the field of diabetes have revolutionized the management, prognosis, and quality of life of diabetes patients and their environment. The aim of our study was to evaluate the impact of implementing the MiniMed 780G closed-loop system in a pediatric and adolescent population previously treated with a continuous subcutaneous insulin infusion pump and intermittent glucose monitoring. METHODS Data were collected from 28 patients with type 1 diabetes aged 6 to 17 years, with a follow-up of 6 months. We included both glucometric and quality of life variables, as well as quality of life in primary caregivers. Metabolic control variables were assessed at baseline (before system change) and at different cutoff points after initiation of the closed-loop system (48 hours, 7 days, 14 days, 21 days, 1 month, 3 months, 6 months). RESULTS Time in range 70-180 mg/dL increased from 59.44% at baseline to 74.29% in the first 48 hours after automation of the new system, and this improvement was maintained at the other cutoff points, as was time in hyperglycemia 180-250 mg/dL (24.44% at baseline to 18.96% at 48 hours) and >250 mg/dL (11.71% at baseline to 3.82% at 48 hours). CONCLUSIONS Our study showed an improvement in time in range and in all time spent in hyperglycemia from the first 48 hours after the automation of the system, which was maintained at 6 months.
Collapse
Affiliation(s)
- Alfonso Lendínez‐Jurado
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
- Universidad de Málaga, Andalucía TechMálagaSpain
| | - Ana Gómez‐Perea
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
- Instituto de Investigación Biomédica de Málaga (IBIMA)MálagaSpain
| | - Ana B. Ariza‐Jiménez
- Department of Pediatric EndocrinologyReina Sofia University HospitalCórdobaSpain
- Instituto Maimónides de Investigación Biomédica de Córdoba (IMIBIC), Universidad de CórdobaCórdobaSpain
| | - Leopoldo Tapia‐Ceballos
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
- Instituto de Investigación Biomédica de Málaga (IBIMA)MálagaSpain
| | - Icía Becerra‐Paz
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
| | - María F. Martos‐Lirio
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
- Universidad de Málaga, Andalucía TechMálagaSpain
| | - Fernando Moreno‐Jabato
- Instituto de Investigación Biomédica de Málaga (IBIMA)MálagaSpain
- Servicio de Supercomputación y Departamento de Arquitectura de ComputadoresUniversidad de MálagaMálagaSpain
| | - Isabel Leiva‐Gea
- Department of Pediatric EndocrinologyRegional University Hospital of MalagaMálagaSpain
- Universidad de Málaga, Andalucía TechMálagaSpain
- Instituto de Investigación Biomédica de Málaga (IBIMA)MálagaSpain
| |
Collapse
|
17
|
Bassi M, Franzone D, Dufour F, Strati MF, Scalas M, Tantari G, Aloi C, Salina A, d’Annunzio G, Maghnie M, Minuto N. Automated Insulin Delivery (AID) Systems: Use and Efficacy in Children and Adults with Type 1 Diabetes and Other Forms of Diabetes in Europe in Early 2023. Life (Basel) 2023; 13:783. [PMID: 36983941 PMCID: PMC10053516 DOI: 10.3390/life13030783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 03/07/2023] [Accepted: 03/10/2023] [Indexed: 03/17/2023] Open
Abstract
Type 1 diabetes (T1D) patients' lifestyle and prognosis has remarkably changed over the years, especially after the introduction of insulin pumps, in particular advanced hybrid closed loop systems (AHCL). Emerging data in literature continuously confirm the improvement of glycemic control thanks to the technological evolution taking place in this disease. As stated in previous literature, T1D patients are seen to be more satisfied thanks to the use of these devices that ameliorate not only their health but their daily life routine as well. Limited findings regarding the use of new devices in different age groups and types of patients is their major limit. This review aims to highlight the main characteristics of each Automated Insulin Delivery (AID) system available for patients affected by Type 1 Diabetes Mellitus. Our main goal was to particularly focus on these systems' efficacy and use in different age groups and populations (i.e., children, pregnant women). Recent studies are emerging that demonstrate their efficacy and safety in younger patients and other forms of diabetes.
Collapse
Affiliation(s)
- Marta Bassi
- IRCCS Istituto Giannina Gaslini, 16147 Genoa, Italy
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Daniele Franzone
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Francesca Dufour
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Marina Francesca Strati
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Marta Scalas
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Giacomo Tantari
- IRCCS Istituto Giannina Gaslini, 16147 Genoa, Italy
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | - Concetta Aloi
- LABSIEM (Laboratory for the Study of Inborn Errors of Metabolism), Pediatric Clinic, IRCCS Istituto Giannina Gaslini, 16147 Genoa, Italy
| | - Alessandro Salina
- LABSIEM (Laboratory for the Study of Inborn Errors of Metabolism), Pediatric Clinic, IRCCS Istituto Giannina Gaslini, 16147 Genoa, Italy
| | | | - Mohamad Maghnie
- IRCCS Istituto Giannina Gaslini, 16147 Genoa, Italy
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, 16126 Genoa, Italy
| | | |
Collapse
|
18
|
Grassi B, Gómez AM, Calliari LE, Franco D, Raggio M, Riera F, Castro M, McVean J, van den Heuvel T, Arrieta A, Castañeda J, Cohen O. Real-world performance of the MiniMed 780G advanced hybrid closed loop system in Latin America: Substantial improvement in glycaemic control with each technology iteration of the MiniMed automated insulin delivery system. Diabetes Obes Metab 2023; 25:1688-1697. [PMID: 36789699 DOI: 10.1111/dom.15023] [Citation(s) in RCA: 19] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 02/06/2023] [Accepted: 02/12/2023] [Indexed: 02/16/2023]
Abstract
AIM We studied real-world performance of MiniMed (MM) 780G system users from Argentina, Brazil, Colombia and Chile (geographical analysis), and the effect of each technology iteration of the MM system on glycaemic control (technology iteration analysis). MATERIALS AND METHODS CareLink data from August 2020 to September 2022 were extracted. Endpoints included continuous glucose monitoring metrics. For the geographical analysis, aggregated endpoints for MM780G system users were calculated. For the technology iteration analysis, MM780G system user outcomes were compared with outcomes when the same individuals were still using the MM640G or MM670G system. RESULTS On average, 1025 MM780G system users from the geographical analysis were followed for 136 (SD 135) days, spent 91.5 (14.3)% in advanced hybrid closed loop, showed a glucose management indicator (GMI) of 6.7 (0.3)%, a time in range between 70 and 180 mg/dl (TIR) of 76.5 (9.0)%, and a time below range 70 mg/dl (TBR) of 2.7 (2.1)%. The percentage of users reaching targets of GMI <7%, TIR >70% and TBR <4% was 80.8%, 78.1% and 80.1%, respectively. The technology iteration analysis on users transitioning from MM640G to MM780G system (N = 381) showed 0.4% decrease in GMI (7.1% to 6.7%, p < .0001), 10.7% increase in TIR (65.9% to 76.6%, p < .0001), while TBR remained. The percentage of insulin delivered automatically increased as well (47.5%-57.7%, p < .0001). Users transitioning from MM670G system (N = 78) showed a similar but less pronounced pattern. CONCLUSIONS Real-world Latin American MM780G users on average showed good glucose control, achieving international targets. Glycaemic control increased with every technology iteration of the MM system, providing more automation each time.
Collapse
Affiliation(s)
- Bruno Grassi
- Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Ana Maria Gómez
- Pontificia Universidad Javeriana, Bogotá, Colombia
- Hospital Universitario de San Ignacio, Bogotá, Colombia
| | | | - Denise Franco
- CPCLIN/DASA Clinical Research Centre, São Paulo, Brazil
| | | | | | | | | | | | - Arcelia Arrieta
- Medtronic International Trading Sarl, Tolochenaz, Switzerland
| | | | - Ohad Cohen
- Medtronic International Trading Sarl, Tolochenaz, Switzerland
| |
Collapse
|
19
|
The Use of a Hybrid Closed-Loop System for Glycemic Control in Two Pediatric Patients with Type 1 Diabetes Undergoing Minor Surgery. Healthcare (Basel) 2023; 11:healthcare11040587. [PMID: 36833120 PMCID: PMC9957216 DOI: 10.3390/healthcare11040587] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 01/22/2023] [Accepted: 02/13/2023] [Indexed: 02/18/2023] Open
Abstract
Technological progress in the treatment of type 1 diabetes requires doctors to use modern methods of insulin therapy in all areas of medicine that patients may come into contact with, including surgical interventions. The current guidelines indicate the possibility of using continuous subcutaneous insulin infusion in minor surgical procedures, but there are few reported cases of using a hybrid closed-loop system in perioperative insulin therapy. This case presentation focuses on two children with type 1 diabetes who were treated with an advanced hybrid closed-loop (AHCL) system during a minor surgical procedure. In the periprocedural period, the recommended mean glycemia and the time in range were maintained.
Collapse
|
20
|
Bassi M, Patti L, Silvestrini I, Strati MF, Ponzano M, Minuto N, Maggi D. One-year follow-up comparison of two hybrid closed-loop systems in Italian children and adults with type 1 diabetes. Front Endocrinol (Lausanne) 2023; 14:1099024. [PMID: 36777356 PMCID: PMC9909036 DOI: 10.3389/fendo.2023.1099024] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 01/16/2023] [Indexed: 01/27/2023] Open
Abstract
BACKGROUND AND AIMS Tandem Control-IQ and MiniMed 780G are the main Advanced Hybrid Closed Loop (AHCL) systems currently available in pediatric and adult patients with Type 1 Diabetes (T1D). The aim of our study was to evaluate glycemic control after 1-year of follow-up extending our previous study of 1-month comparison between the two systems. METHODS We retrospectively compared clinical and continuous glucose monitoring (CGM) data from the patients included in the previous study which have completed 1-year observation period. The study population consisted of 74 patients, 42 Minimed 780G users and 32 Tandem Control-IQ users. Linear mixed models with random intercept were performed to study the variations over time and the interaction between time and system; Mann-Whitney or T-test were used to compare systems at 1-year. RESULTS Both systems have been shown to be effective in maintaining the glycemic improvement achieved one month after starting AHCL. Significant changes over time were observed for TIR, TAR, TAR>250mg/dl, average glucose levels and SD (p<0.001). At 1-year follow-up Minimed 780G obtained better improvement in TIR (p<0.001), TAR (p=0.002), TAR>250mg/dl (p=0.001), average glucose levels (p<0.001). The comparison of the glycemic parameters at 1-year showed a significant superiority of Minimed 780G in terms of TIR (71% vs 68%; p=0.001), TAR (p=0.001), TAR>250 (p=0.009), average glucose levels(p=0.001) and SD (p=0.031). CONCLUSIONS The use of AHCL systems led to a significant improvement of glycemic control at 1-month, which is maintained at 1-year follow-up. MiniMed is more effective than Tandem in reaching the International recommended glycemic targets. Continuous training and education in the use of technology is essential to get the best out of the most advanced technological tools.
Collapse
Affiliation(s)
- Marta Bassi
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, Genoa, Italy
- Department of Pediatrics, IRCCS Istituto Giannina Gaslini, University of Genoa, Genoa, Italy
| | - Luca Patti
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
| | - Irene Silvestrini
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
| | - Marina Francesca Strati
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, Genoa, Italy
- Department of Pediatrics, IRCCS Istituto Giannina Gaslini, University of Genoa, Genoa, Italy
| | - Marta Ponzano
- Department of Health Science (DiSSAL), University of Genoa, Genoa, Italy
| | - Nicola Minuto
- Department of Pediatrics, IRCCS Istituto Giannina Gaslini, University of Genoa, Genoa, Italy
- *Correspondence: Nicola Minuto,
| | - Davide Maggi
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
- Diabetes Clinic, IRCCS Ospedale Policlinico San Martino Genoa, Genoa, Italy
| |
Collapse
|
21
|
Beato-Víbora PI, Ambrojo-López A, Fernández-Bueso M, Gil-Poch E, Javier Arroyo-Díez F. Long-term outcomes of an advanced hybrid closed-loop system: A focus on different subpopulations. Diabetes Res Clin Pract 2022; 191:110052. [PMID: 36030902 DOI: 10.1016/j.diabres.2022.110052] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Revised: 08/18/2022] [Accepted: 08/22/2022] [Indexed: 11/20/2022]
Abstract
BACKGROUND The long-term benefit provided by advanced hybrid closed-loop (AHCL) systems needs to be assessed in general populations and specific subpopulations. METHODS A prospective evaluation of subjects initiating the AHCL system 780G was performed. Time in range (70-180 mg/dl) (TIR), <70 mg/dl, <54 mg/dl, >180 mg/dl and >250 mg/dl were compared, at baseline and after one year, in different subpopulations, according to previous treatment (pump vs MDI), age (> or ≤25 years old) and hypoglycaemia risk at baseline. RESULTS 135 subjects were included (age: 35 ± 15 years, 64 % females, diabetes duration: 21 ± 12 years). An increase in TIR was found, from 67.26 ± 11.80 % at baseline to 77.41 ± 8.85 % after one year (p < 0.001). All the subgroups showed a significant improvement in TIR, time > 180 mg/dl and >250 mg/dl. At the 1-year evaluation, no significant differences were found, between previous pump users and MDI subjects. Children and young adults had a lower time < 70 mg/dl than adults. Subjects with a high risk of hypoglycaemia at baseline had a higher time spent at <70 mg/dl and <54 mg/dl than low-risk individuals. CONCLUSION The initial benefit provided by the AHCL system is sustained in the long term. MDI subjects obtain the same outcomes as subjects with pump experience.
Collapse
Affiliation(s)
- Pilar Isabel Beato-Víbora
- Diabetes Technology Unit, Endocrinology and Nutrition Department, Badajoz University Hospital, Badajoz, Spain.
| | - Ana Ambrojo-López
- Diabetes Technology Unit, Endocrinology and Nutrition Department, Badajoz University Hospital, Badajoz, Spain
| | - Mercedes Fernández-Bueso
- Diabetes Technology Unit, Endocrinology and Nutrition Department, Badajoz University Hospital, Badajoz, Spain
| | - Estela Gil-Poch
- Diabetes Technology Unit, Department of Paediatrics, Badajoz University Hospital, Badajoz, Spain
| | | |
Collapse
|
22
|
Abstract
PURPOSE OF REVIEW Closed-loop insulin pump systems (artificial pancreas) represent the cutting edge of insulin delivery technology. There are only a few systems currently approved for use in the USA: the MiniMed 670G/770G (which share an algorithm), t:slim X2 Control IQ, and the Omnipod 5. We review these systems and look into the future of the technology. RECENT FINDINGS All of the approved closed-loop insulin pump systems have demonstrated in multicenter prospective trials improvements in time in range, hemoglobin A1c, and time spent in hypoglycemia. The newer systems have also improved time spent in automation. Comparisons between the systems with regard to glycemic control are difficult to make due to differences in clinical trial design, but there are notable differences in the user experience between systems. The past few years have been a time of exponential development in the field of closed-loop insulin pump systems. However, more research is needed to provide full automation of these systems without any need for information from the user.
Collapse
Affiliation(s)
- Keren Zhou
- Endocrinology and Metabolism Institute, Cleveland Clinic, 9500 Euclid Avenue, F20, Cleveland, OH, 44195, US.
| | - Diana Isaacs
- Endocrinology and Metabolism Institute, Cleveland Clinic, 9500 Euclid Avenue, F20, Cleveland, OH, 44195, US
| |
Collapse
|
23
|
Bassi M, Teliti M, Lezzi M, Iosca A, Strati MF, Carmisciano L, d’Annunzio G, Minuto N, Maggi D. A Comparison of Two Hybrid Closed-Loop Systems in Italian Children and Adults With Type 1 Diabetes. Front Endocrinol (Lausanne) 2021; 12:802419. [PMID: 35116007 PMCID: PMC8805205 DOI: 10.3389/fendo.2021.802419] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 12/23/2021] [Indexed: 12/11/2022] Open
Abstract
Tandem Control-IQ and Minimed 780G represent the most Advanced Hybrid Closed Loop (AHCL) systems currently available in pediatric and adult subjects with Type 1 Diabetes (T1D). We retrospectively compared clinical and continuous glucose monitoring data from 51 patients who upgraded to Minimed 780G system and have completed 1-month observation period with data from 39 patients who upgraded to Tandem Control-IQ. Inverse probability weighting was used to minimize the basal characteristics imbalances. Both AHCL systems showed a significant improvement in glycemic parameters. Minimed 780G group achieved higher TIR increase (p= 0.004) and greater reduction of blood glucose average (p= 0.001). Tandem Control-IQ system significantly reduced the occurrence of TBR (p= 0.010) and the Coefficient of Variation of glucose levels (p= 0.005). The use of ACHL systems led to a significant improvement of glycemic control substantially reaching the International recommended glycemic targets. Minimed 780G appears to be more effective in managing hyperglycemia, while Tandem Control-IQ seems to be more effective in reducing time in hypoglycemia.
Collapse
Affiliation(s)
- Marta Bassi
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, Genoa, Italy
- Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Giannina Gaslini, Genoa, Italy
| | - Marsida Teliti
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
| | - Marilea Lezzi
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, Genoa, Italy
- Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Giannina Gaslini, Genoa, Italy
| | - Arianna Iosca
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
| | - Marina Francesca Strati
- Department of Neuroscience, Rehabilitation, Ophthalmology, Genetics, Maternal and Child Health, University of Genoa, Genoa, Italy
- Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Giannina Gaslini, Genoa, Italy
| | - Luca Carmisciano
- Department of Helath Science (DiSSAL), University of Genoa, Genoa, Italy
| | - Giuseppe d’Annunzio
- Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Giannina Gaslini, Genoa, Italy
| | - Nicola Minuto
- Department of Pediatrics, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Istituto Giannina Gaslini, Genoa, Italy
- *Correspondence: Nicola Minuto,
| | - Davide Maggi
- Department of Internal Medicine and Medical Specialties (DiMI), University of Genoa, Genoa, Italy
- Department of Helath Science (DiSSAL), University of Genoa, Genoa, Italy
- Diabetes Clinic, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS) Ospedale Policlinico San Martino Genoa, Genoa, Italy
| |
Collapse
|