1
|
El Azab NF, Abdelaal SH, Hassan SA, El-Kosasy AM. Dietary supplement mislabelling: case study on selected slimming products by developing a green isocratic HPLC method for their quality control. Sci Rep 2022; 12:22305. [PMID: 36566240 PMCID: PMC9790016 DOI: 10.1038/s41598-022-24830-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Accepted: 11/21/2022] [Indexed: 12/25/2022] Open
Abstract
Nowadays, a huge population consumes Dietary supplements for losing weight. Products are often claimed as botanical blends, yet they aren't necessarily safe. Misleading labels are also very common. Thus, validated analytical methods for a wide range of slimming compounds are highly needed. Herein, we present a simple HPLC/PDA method for the quantitation of seven popular slimming ingredients. Studied compounds were Caffeine, Raspberry Ketone, trans-Resveratrol, p-Synephrine, p-Octopamine, p-Hordenine and 2-phenethylamine. After optimization, separation was carried out on a C18 column and mobile phase was a mixture of Acetonitrile:Water containing 0.1% phosphoric acid (50:50, %v/v). The last compound was eluted at 9.76 min. Separation was efficient showing baseline- separated symmetric peaks, without using any gradient programs, organic mobile phase modifiers or modified stationary phases. Method validation was done following ICH guidelines. Calibration curves were linear over wide concentration ranges and calculated LOD values were in the range 0.02-0.09 µg/mL. Method greenness was assessed using Analytical Eco-scale, GAPI and AGREE metric tools. Further, four random sample products purchased from online supplement stores were assayed. Results proved some mislabeling actions. To support our findings, standard addition was carried out and average % recoveries were 96.67 - 101.44% with standard deviation ≤ 2.83 between measurements.
Collapse
Affiliation(s)
- Noha F. El Azab
- grid.7269.a0000 0004 0621 1570Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566 Egypt
| | - Sarah H. Abdelaal
- grid.7269.a0000 0004 0621 1570Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566 Egypt
| | - Said A. Hassan
- grid.7776.10000 0004 0639 9286Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Kasr El-Aini Street, Cairo, 11562 Egypt
| | - Amira M. El-Kosasy
- grid.7269.a0000 0004 0621 1570Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566 Egypt
| |
Collapse
|
2
|
Kariyil B, Akhil GH, Akshatha GD, Vasudhar Bhatt SV, Dhanusha G, John R. Germinated seeds of Hordeum vulgare target extrinsic pathway of apoptosis in triple-negative breast cancer cells. Pharmacogn Mag 2020. [DOI: 10.4103/pm.pm_123_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
|
3
|
Sommer T, Dlugash G, Hübner H, Gmeiner P, Pischetsrieder M. Monitoring of the dopamine D2 receptor agonists hordenine and N-methyltyramine during the brewing process and in commercial beer samples. Food Chem 2019; 276:745-753. [DOI: 10.1016/j.foodchem.2018.10.067] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 10/09/2018] [Accepted: 10/12/2018] [Indexed: 01/17/2023]
|
4
|
Viana C, Zemolin GM, Dal Molin TR, Gobo L, Ribeiro SM, Leal GC, Marcon GZ, de Carvalho LM. Detection and determination of undeclared synthetic caffeine in weight loss formulations using HPLC-DAD and UHPLC-MS/MS. J Pharm Anal 2017; 8:366-372. [PMID: 30595942 PMCID: PMC6308025 DOI: 10.1016/j.jpha.2017.12.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Revised: 11/05/2017] [Accepted: 12/11/2017] [Indexed: 02/07/2023] Open
Abstract
Caffeine is present in products marketed for weight loss, with the purpose of increasing thermogenesis and lipid metabolism. The dosage declared by the product manufacturer, or even its presence, is not always correctly described on the label. This work aimed to investigate the undeclared synthetic caffeine in weight loss formulations by a high-performance liquid chromatography with diode array detection (HPLC-DAD) method. From one hundred products purchased through Brazilian e-commerce, seventeen contained caffeine, either naturally or synthetically added to formulation. The caffeine-containing samples were confirmed by an ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method, and adulteration was clearly proven in five products. The content highest caffeine contained 448.8 mg per dose. Other irregularities were also found; nevertheless, the most serious was the addition of synthetic drugs without asking the consumers. Additional drugs expose the consumer to more possible side-effects as well as deleterious drug interactions. Intentional adulteration with any unlabeled substance is typically motivated by a desire to increase or alter the claimed effect of the marketed product to gain a commercial advantage.
Collapse
Affiliation(s)
- Carine Viana
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil.,Center of Health Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Gabriela M Zemolin
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Thaís R Dal Molin
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Luciana Gobo
- Department of Chemistry, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Sandra Maria Ribeiro
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Gabriela C Leal
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Gabriela Z Marcon
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| | - Leandro M de Carvalho
- Graduate Program in Pharmaceutical Sciences, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil.,Department of Chemistry, Federal University of Santa Maria (UFSM), Santa Maria-RS, Brazil
| |
Collapse
|
5
|
Zhang Y, Zhang M, Wei Q, Gao Y, Guo L, Al-Ghanim KA, Mahboob S, Zhang X. An Easily Fabricated Electrochemical Sensor Based on a Graphene-Modified Glassy Carbon Electrode for Determination of Octopamine and Tyramine. SENSORS 2016; 16:s16040535. [PMID: 27089341 PMCID: PMC4851049 DOI: 10.3390/s16040535] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/04/2016] [Revised: 04/05/2016] [Accepted: 04/11/2016] [Indexed: 11/16/2022]
Abstract
A simple electrochemical sensor has been developed for highly sensitive detection of octopamine and tyramine by electrodepositing reduced graphene oxide (ERGO) nanosheets onto the surface of a glassy carbon electrode (GCE). The electrocatalytic oxidation of octopamine and tyramine is individually investigated at the surface of the ERGO modified glassy carbon electrode (ERGO/GCE) by using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Several essential factors including the deposition cycle of reduced graphene oxide nanosheets and the pH of the running buffer were investigated in order to determine the optimum conditions. Furthermore, the sensor was applied to the quantification of octopamine and tyramine by DPV in the concentration ranges from 0.5 to 40 μM and 0.1 to 25 μM, respectively. In addition, the limits of detection of octopamine and tyramine were calculated to be 0.1 μM and 0.03 μM (S/N = 3), respectively. The sensor showed good reproducibility, selectivity and stability. Finally, the sensor successfully detected octopamine and tyramine in commercially available beer with satisfactory recovery ranges which were 98.5%–104.7% and 102.2%–103.1%, respectively. These results indicate the ERGO/GCE based sensor is suitable for the detection of octopamine and tyramine.
Collapse
Affiliation(s)
- Yang Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| | - Meiqin Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| | - Qianhui Wei
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| | - Yongjie Gao
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| | - Lijuan Guo
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| | - Khalid A Al-Ghanim
- Department of Zoology, College of Science, P. O. Box 2455, King Saud University, Riyadh 11451, Saudi Arabia.
| | - Shahid Mahboob
- Department of Zoology, College of Science, P. O. Box 2455, King Saud University, Riyadh 11451, Saudi Arabia.
- Department of Zoology, Government College University, Fsisalabad 38000, Pakistan.
| | - Xueji Zhang
- Research Center for Bioengineering and Sensing Technology, University of Science and Technology, Beijing 100083, China.
| |
Collapse
|
6
|
Viana C, Zemolin GM, Müller LS, Dal Molin TR, Seiffert H, de Carvalho LM. Liquid chromatographic determination of caffeine and adrenergic stimulants in food supplements sold in Brazilian e-commerce for weight loss and physical fitness. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2015; 33:1-9. [DOI: 10.1080/19440049.2015.1112040] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
7
|
Validated UPLC–MS/MS method for determination of hordenine in rat plasma and its application to pharmacokinetic study. J Pharm Biomed Anal 2015; 111:131-7. [DOI: 10.1016/j.jpba.2015.03.032] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2014] [Revised: 03/20/2015] [Accepted: 03/26/2015] [Indexed: 11/20/2022]
|
8
|
Chen Y, Meng J, Zou J, An J. Selective extraction based on poly(MAA-VB-EGMDA) monolith followed by HPLC for determination of hordenine in plasma and urine samples. Biomed Chromatogr 2014; 29:869-75. [PMID: 25355709 DOI: 10.1002/bmc.3367] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2014] [Revised: 08/08/2014] [Accepted: 09/25/2014] [Indexed: 01/08/2023]
Abstract
Hordenine is an active compound found in several foods, herbs and beer. In this work, a novel sorbent was fabricated for selective solid-phase extraction (SPE) of hordenine in biological samples. The organic polymer sorbent was synthesized in one step in the plastic barrel of a syringe by a pre-polymerization solution consisting of methacrylic acid (MAA), 4-vinylphenylboronic acid (VB) and ethylene glycol dimethacrylate (EGDMA). The conditions for preparation were optimized to generate a poly(MAA-VB-EGMDA) monolith with good permeability. The monolith exhibited good enrichment efficiency towards hordenine. By using tyramine as the internal standard, a poly(MAA-VB-EGMDA)-based SPE-HPLC method was established for analysis of hordenine. Conditions for SPE, including volume of eluting solvent, pH of sample solution, sampling rate and sample volume, were optimized. The proposed SPE-HPLC method presented good linearity (R(2) = 0.9992) within 10-2000 ng/mL and the detection limits was 3 ng/mL, which is significantly more sensitive than reported methods. The method was also applied in plasma and urine samples; good capability of removing matrices was observed, while hordenine in low content was well extracted and enriched. The recoveries were from 90.6 to 94.7% and from 89.3 to 91.5% for the spiked plasma and urine samples, respectively, with the relative standard deviations <4.7%.
Collapse
Affiliation(s)
- Yonggang Chen
- Department of Pharmacy, The Third Hospital of Wuhan, Wuhan, Hubei, 430060, People's Republic of China
| | - Junhua Meng
- Department of Pharmacy, The Third Hospital of Wuhan, Wuhan, Hubei, 430060, People's Republic of China
| | - Jili Zou
- Department of Pharmacy, The Third Hospital of Wuhan, Wuhan, Hubei, 430060, People's Republic of China
| | - Jing An
- Department of Pharmacy, The Third Hospital of Wuhan, Wuhan, Hubei, 430060, People's Republic of China
| |
Collapse
|