Thomas GW. How bedside feedback improves head-of-bed angle compliance for intubated patients.
ACTA ACUST UNITED AC 2017;
7:73-80. [PMID:
31187082 DOI:
10.1080/24725579.2017.1281851]
[Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
One clinical defense against ventilator-associated pneumonia is maintaining the head-of-bed angle of ventilated patients above 30°. Most previous studies of head-of-bed angles using electronic monitoring have recorded compliance rates of less than 50%. The purpose of this study was to determine how bedside feedback of the head-of-bed angle affects bed angles set by healthcare workers. Electronic inclinometers were installed on 22 beds in an intensive care for a period of 38 days. Intubated patients were randomly assigned into two cohorts. One cohort received a graphical display of the bed angle adjacent to the in-room computer display. The head-of-bed angle of each intubated patient was continuously recorded, yielding 1,528 h of observation. The mean head-of-bed angle was 28.78° for beds with displays and 25.50° for those without, a significant difference. The most significant effects were for angles near 30°. Beds in the display cohort were three times as likely to be in a compliant position as beds in the no-display cohort. The results suggest that electronic bedside feedback improves head-of-bed angle compliance by raising angles slightly below the compliance threshold into compliance. This result may support studies of how compliant bed-angle protocols affect health outcomes.
Collapse