1
|
Le Basle Y, Chennell P, Tokhadze N, Astier A, Sautou V. Physicochemical Stability of Monoclonal Antibodies: A Review. J Pharm Sci 2020; 109:169-190. [DOI: 10.1016/j.xphs.2019.08.009] [Citation(s) in RCA: 118] [Impact Index Per Article: 29.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 08/19/2019] [Accepted: 08/19/2019] [Indexed: 01/10/2023]
|
2
|
Horak J, Lämmerhofer M. Racemization without deamidation: Effect of racemization conditions on 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate tagged amino acids. J Chromatogr A 2019; 1604:460492. [PMID: 31488295 DOI: 10.1016/j.chroma.2019.460492] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 08/23/2019] [Accepted: 08/27/2019] [Indexed: 01/01/2023]
Abstract
The aim of this research study was to provide a more thorough understanding of the underlying mechanism and to broaden the application field of the recently introduced racemization method employing the amino acid derivatization tag 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC, AccQ) for heat-induced stereoisomerization of common amino acids as well as uniformly isotopically labeled [U-13C15N]-amino acids. The influence of different buffer types such as sodium borate buffer and sodium carbonate buffer as well as their pH and molarity on the racemization and deamidation of amino acids were investigated. It was found that a 0.4 M borate buffer with a pH of 8.0 +/- 0.2 was the most suitable derivatization as well as racemization buffer to ensure degradation free racemization of deamidation prone compounds such as glutamine. Hereby essential was the in-solution pH measurement before and after derivatization with AQC as well as after heat-induced racemization. This strategy provided further insight at which pH an actual racemization event was observed and when an unwanted deamidation of glutamine to glutamic acid occurred. In addition also the influence of the presence of oxygen during racemization was studied. In this context it was possible to determine ideal oxidation and racemization conditions for the production of scalemic mixtures of chiral isotopically labeled methionine AQC-DL-[U-13C15N]-Met as well as its oxidation products, AQC-DL-[U-13C15N]-Met-O and AQC-DL-[U-13C15N]-Met-O2. All stereoselective separations were performed on the zwitterionic Chiralpak ZWIX(+) column combined with HPLC-ESI-QTOF-MS analysis in positive ionization mode.
Collapse
Affiliation(s)
- Jeannie Horak
- Eberhard-Karls-University Tuebingen, Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, Auf der Morgenstelle 8 (Haus B), 72076 Tuebingen, Germany.
| | - Michael Lämmerhofer
- Eberhard-Karls-University Tuebingen, Institute of Pharmaceutical Sciences, Pharmaceutical (Bio-)Analysis, Auf der Morgenstelle 8 (Haus B), 72076 Tuebingen, Germany
| |
Collapse
|
3
|
Horká M, Růžička F, Kubesová A, Šlais K. Dynamic labeling of diagnostically significant microbial cells in cerebrospinal fluid by red chromophoric non-ionogenic surfactant for capillary electrophoresis separations. Anal Chim Acta 2012; 728:86-92. [DOI: 10.1016/j.aca.2012.03.045] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2012] [Revised: 03/21/2012] [Accepted: 03/26/2012] [Indexed: 02/08/2023]
|
4
|
Horká M, Růžička F, Holá V, Kahle V, Moravcová D, Šlais K. Capillary Electromigration Separation of Proteins and Microorganisms Dynamically Modified by Chromophoric Nonionogenic Surfactant. Anal Chem 2009; 81:6897-904. [DOI: 10.1021/ac900897c] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Marie Horká
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| | - Filip Růžička
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| | - Veronika Holá
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| | - Vladislav Kahle
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| | - Dana Moravcová
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| | - Karel Šlais
- Institute of Analytical Chemistry Academy of Sciences of the Czech Republic, v. v. i., Veveří 97, 602 00 Brno, Czech Republic, and Department of Microbiology, Faculty of Medicine, Masaryk University Brno, Czech Republic
| |
Collapse
|
5
|
Horká M, Růzicka F, Holá V, Slais K. CE separation of proteins and yeasts dynamically modified by PEG pyrenebutanoate with fluorescence detection. Electrophoresis 2007; 28:2300-7. [PMID: 17557360 DOI: 10.1002/elps.200600710] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The optimized protocols of the bioanalytes separation, proteins and yeasts, dynamically modified by the nonionogenic tenside PEG pyrenebutanoate, were applied in CZE and CIEF with the acidic gradient in pH range 2-5.5, both with fluorescence detection. PEG pyrenebutanoate was used as a buffer additive for a dynamic modification of proteins and/or yeast samples. The narrow peaks of modified analytes were detected. The values of the pI's of the labeled proteins were calculated using new fluorescent pI markers in CIEF and they were found to be comparable with pI's of the native compounds. As an example of the possible use of the suggested CIEF technique, the mixed cultures of yeasts, Candida albicans, Candida glabrata, Candida kefyr, Candida krusei, Candida lusitaniae, Candida parapsilosis, Candida tropicalis, Candida zeylanoides, Geotrichum candidum, Saccharomyces cerevisiae, Trichosporon asahii and Yarrowia lipolytica, were reproducibly focused and separated with high sensitivity. Using UV excitation for the on-column fluorometric detection, the minimum detectable amounts of analytes, femtograms of proteins and down to ten cells injected on the separation capillary, were estimated.
Collapse
Affiliation(s)
- Marie Horká
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic.
| | | | | | | |
Collapse
|
6
|
Abstract
CE- and microchip-based separations coupled with LIF are powerful tools for the separation, detection and determination of biomolecules. CE with certain configurations has the potential to detect a small number of molecules or even a single molecule, thanks to the high spatial coherence of the laser source which permits the excitation of very small sample volumes with high efficiency. This review article discusses the use of LIF detection for the analysis of peptides and proteins in CE. The most common laser sources, basic instrumentation, derivatization modes and set-ups are briefly presented and special attention is paid to the different fluorogenic agents used for pre-, on- and postcapillary derivatization of the functional groups of these compounds. A table summarizing major applications of these derivatization reactions to the analysis of peptides and proteins in CE-LIF and a bibliography with 184 references are provided which covers papers published to the end of 2005.
Collapse
|
7
|
Horka M, Ruzicka F, Horký J, Holá V, Slais K. Capillary Isoelectric Focusing and Fluorometric Detection of Proteins and Microorganisms Dynamically Modified by Poly(ethylene glycol) Pyrenebutanoate. Anal Chem 2006; 78:8438-44. [PMID: 17165837 DOI: 10.1021/ac061200h] [Citation(s) in RCA: 30] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The nonionogenic pyrene-based tenside, poly(ethylene glycol) pyrenebutanoate, was prepared and applied in capillary isoelectric focusing with fluorometric detection. This dye was used here as a buffer additive in capillary isoelectric focusing for a dynamic modification of the sample of proteins and microorganisms. The values of the isoelectric points of the labeled bioanalytes were calculated with use of the fluorescent pI markers and were found comparable with pI of the native compounds. The mixed cultures of proteins and microorganisms, Escherichia coli CCM 3954, Staphylococcus epidermidis CCM 4418, Proteus vulgaris, Enterococcus faecalis CCM 4224, and Stenotrophomonas maltophilia, the strains of the yeast cells, Candida albicans CCM 8180, Candida krusei, Candida parapsilosis, Candida glabrata, Candida tropicalis, and Saccharomyces cerevisiae were reproducibly focused and separated by the suggested technique. Using UV excitation for the on-column fluorometric detection, the minimum detectable amount was down to 10 cells injected on the separation capillary.
Collapse
Affiliation(s)
- Marie Horka
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Veverí 97, 61142 Brno, Czech Republic.
| | | | | | | | | |
Collapse
|
8
|
Salas-Solano O, Tomlinson B, Du S, Parker M, Strahan A, Ma S. Optimization and Validation of a Quantitative Capillary Electrophoresis Sodium Dodecyl Sulfate Method for Quality Control and Stability Monitoring of Monoclonal Antibodies. Anal Chem 2006; 78:6583-94. [PMID: 16970337 DOI: 10.1021/ac060828p] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In previous work, a capillary electrophoresis sodium dodecyl sulfate (CE-SDS) method using precolumn labeling and laser-induced fluorescence (LIF) detection was developed at Genentech Inc. as part of the control system for the quality control release of a recombinant monoclonal antibody (rMAb) (Hunt, G.; Nashabeh, W. Anal. Chem. 1999, 71, 2390-2397.). In the current work, a generic and quantitative CE-SDS assay with LIF detection of rMAbs with improved accuracy and precision is described. The implementation of an alkylating step with iodoacetamide and optimization of the incubation temperature and time, in the presence of SDS, greatly decrease any thermally induced fragmentation of nonreduced labeled rMAb samples. In addition, a quantitative study of the effects of sample buffer pH on rMAb fragmentation is also presented. Furthermore, the performance of alternative CE-SDS polymer solutions and instrumentation for quantitative analysis of rMAbs is shown in this article. The validation of this method, under the guidelines of the International Committee on Harmonization (ICH), demonstrates that the assay quantitatively determines the consistency of rMAb manufacture as it relates to size heterogeneity and product purity.
Collapse
Affiliation(s)
- Oscar Salas-Solano
- Department of Late Stage Analytical Development, Genentech, Inc., South San Francisco, California 94080, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Ullmer R, Plematl A, Rizzi A. Derivatization by 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate for enhancing the ionization yield of small peptides and glycopeptides in matrix-assisted laser desorption/ionization and electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2006; 20:1469-79. [PMID: 16586471 DOI: 10.1002/rcm.2464] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
The characterization of glycosylation in proteins by mass spectrometry (MS) is often impeded by strong suppression of ionization of glycopeptides in the presence of non-glycosylated peptides. Glycopeptides with a large carbohydrate part and a short peptide backbone are particularly affected by this problem. To meet the goal of generating mass spectra exhibiting glycopeptide coverages as complete as possible, derivatization of glycopeptides offers a practical way to increase their ionization yield. This paper investigated derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) which is a rapid labeling technique commonly used for fluorescence detection in high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE). As test samples we used peptides and glycopeptides obtained by enzymatic digestion of three different glycoproteins, i.e., human antithrombin, chicken ovalbumin, and bovine alpha1-acid-glycoprotein. It was found that AQC derivatization resulted in strongly increased signal intensities when analyzing small peptides and glycopeptides by matrix-assisted laser desorption/ionization (MALDI)-MS. For these compounds the limit of detection could be reduced to low fmol amounts. Without derivatization only glycopeptides containing large peptide backbones were detected by MALDI-MS. This effect was even significant when glycopeptides were pre-separated and enriched by means of lectin affinity chromatography before MALDI-MS analysis and when using electrospray ionization (ESI). This labeling method, applied in combination with MS detection for the first time, was found to be well suited for the enhancement of detection sensitivity for small glycopeptides in MALDI-MS analysis and thus for reducing the need for pre-separation steps.
Collapse
Affiliation(s)
- Roman Ullmer
- Institute of Analytical Chemistry and Food Chemistry, University of Vienna, Währinger Strasse 38, A-1090 Vienna, Austria
| | | | | |
Collapse
|
10
|
Horká M, Růzicka F, Holá V, Slais K. Dynamic modification of microorganisms by pyrenebutanoate for fluorometric detection in capillary zone electrophoresis. Electrophoresis 2005; 26:548-55. [PMID: 15690456 DOI: 10.1002/elps.200406082] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Pyrenebutanoate, a fluorescent amphiphilic probe, is suggested here as a capillary zone electrophoresis (CZE) buffer additive for dynamic modification and analysis of microbial cells. Mixed cultures of microorganisms Escherichia coli, Candida albicans, Enterococcus faecalis and Staphylococcus epidermidis were concentrated, resolved by CZE and detected. Using UV excitation for on-column fluorometric detection, a detection sensitivity for the microorganisms on the order of from one to tens of injected cells was achieved.
Collapse
Affiliation(s)
- Marie Horká
- Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno.
| | | | | | | |
Collapse
|
11
|
Quantitation of Amino Acids as 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate Derivatives. ACTA ACUST UNITED AC 2005. [DOI: 10.1016/s0301-4770(05)80011-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
|
12
|
Sun C, Yang J, Li L, Wu X, Liu Y, Liu S. Advances in the study of luminescence probes for proteins. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 803:173-90. [PMID: 15063324 DOI: 10.1016/j.jchromb.2003.12.039] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2003] [Accepted: 12/16/2003] [Indexed: 11/30/2022]
Abstract
Spectral probes (or labels) have been widely used for the investigation and determination of proteins and have made considerable progress. Traditional luminescence probes include fluorescent derivatizing reagents, fluorescent probes and chemiluminescence probes which continue to develop. Of them, near infrared (NIR) fluorescent probes are especially suitable for the determination of biomolecules including proteins, so their development has been rapid. Novel luminescence probes (such as nanoparticle probes and molecular beacons) and resonance light scattering probes recently appeared in the literature. Preliminary results indicate that they possess great potential for ultrasensitive protein detection. This review summarizes recent developments of the above-mentioned probes for proteins and 195 references are cited.
Collapse
Affiliation(s)
- Changxia Sun
- Key Laboratory for Colloid and Interface Chemistry of Education Ministry, Department of Chemistry, Shandong University, Jinan 250100, PR China
| | | | | | | | | | | |
Collapse
|
13
|
Abstract
The article gives a comprehensive review on the recent developments in the applications of high-performance capillary electromigration methods, including zone electrophoresis, isotachophoresis, isoelectric focusing, affinity electrophoresis, electrokinetic chromatography and electrochromatography, to analysis, preparation and physicochemical characterization of peptides. The article presents new approaches to the theoretical description and experimental verification of electromigration behavior of peptides, and covers the methodological aspects of capillary electroseparations of peptides, such as strategy and rules for the rational selection of separation mode and experimental conditions, sample treatment, suppression of peptide adsorption to the inner capillary wall, new developments in individual separation modes and new designs of detection systems. Several types of applications of capillary electromigration methods to peptide analysis are presented: conventional qualitative and quantitative analysis for determination of purity, determination in biomatrices, monitoring of physical and chemical changes and enzymatic conversions, amino acid and sequence analysis and peptide mapping of proteins. Some examples of micropreparative peptide separations are given and capabilities of capillary electromigration techniques to provide important physicochemical characteristics of peptides are demonstrated.
Collapse
Affiliation(s)
- V Kasicka
- Institute of Organic Chemistry and Biochemistry, Academy of Sciences of the Czech Republic, Prague.
| |
Collapse
|
14
|
Liu HJ, Strong RE, Krull IS, Cohen SA. Homogeneous preparation of fluorescent-derivatized insulin and its application to competitive chromatographic immunoassays. Anal Biochem 2001; 298:103-11. [PMID: 11673901 DOI: 10.1006/abio.2001.5361] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A homogeneously labeled insulin sample was prepared using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) as the fluorescent-labeling reagent, and this was successfully applied to a chromatographic immunoassay. This labeled insulin was prepared by tagging all the three amino groups with AQC. Both CE and chromatographic immunoassay experiments indicated that the prepared insulin still kept its immunoaffinity to its antibody. It was observed that appropriate concentrations of acetonitrile (ACN) were efficient in lowering the quenching of the fluorescent signal of tagged insulin, in keeping the dilute, tagged insulin in solution, and in improving its peak shape during a chromatographic immunoassay. The tagged insulin was found to be 20-400 times more sensitive than native insulin detected under ultraviolet detection conditions. A competitive chromatographic immunoassay system was set up and calibrated. The system was used for analyses of an insulin-spiked urine sample, with a 96% recovery obtained.
Collapse
Affiliation(s)
- H J Liu
- Department of Chemistry, Northeastern University, 102 Hurtig Building, 360 Huntington Avenue, Boston, Massachusetts 02115, USA
| | | | | | | |
Collapse
|
15
|
Abstract
This review article with 223 references describes recent developments in capillary electrophoresis (CE) of proteins and covers papers published during last two years, from the previous review (V. Dolnik, Electrophoresis 1999, 20, 3106-3115) through Spring 2001. It describes the topics related to CE of proteins including modeling of the electrophoretic properties of proteins, sample pretreatment, wall coatings, improving selectivity, detection, special electrophoretic techniques, and applications.
Collapse
Affiliation(s)
- V Dolnik
- Molecular Dynamics, Sunnyvale, CA 94085, USA.
| | | |
Collapse
|
16
|
Abstract
A method of homogeneously derivatizing large proteins for highly sensitive analysis is described. Homogeneity of the derivative was realized by tagging all the free amino groups of proteins. With this method, alpha-chymotrypsinogen A, ovalbumin and bovine serum albumin were derivatized with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC). Prior to the derivatization, all the proteins were reduced and alkylated. After reacting the resulting unfolded proteins with excessive amounts of AQC, the samples were analyzed with matrix assisted laser desorption ionization-time of flight-mass spectrometry (MALDI-TOF-MS) to determine the derivatization degree. The results indicated that all three proteins had been, or had almost been, fully derivatized. HPLC and CE were used for characterizing these protein derivatives. Under the optimized fluorescence detection conditions, the detectability of the tagged proteins was 2400-6200 times better than that detected at UV 280 nm, 170-300 times better than detected at UV 214 nm, and 150-420 times better than measured with their native fluorescence.
Collapse
Affiliation(s)
- H Liu
- Department of Chemistry, Northeastern University, Boston, MA 02115, USA
| | | | | | | |
Collapse
|
17
|
Liu H, Krull IS, Cohen SA. Femtomole peptide mapping by derivatization, high-performance liquid chromatography, and fluorescence detection. Anal Biochem 2001; 294:7-18. [PMID: 11412000 DOI: 10.1006/abio.2001.5142] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A highly sensitive peptide mapping method using derivatization and fluorescence detection is described. Bovine cytochrome c was digested using a buffer compatible with the derivatization that followed. The derivatization was performed with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. The peptide mapping of the tagged digest was conducted with both HPLC and capillary LC (CLC) systems. A capillary LC-electrospray ionization mass spectrometer (MS) was set up for measuring the molecular weights of the tagged peptides. Optimization was made of the conditions used for digestion, derivatization, and mapping. MS measurements of the tagged peptides suggested that there was only one derivatization product produced from all peptides (except one) and that all the identified peptides were fully tagged. Peptide mapping of the tagged digest reviews a larger number of peptides, covering almost the entire sequence. Peptide mapping of a 20 fmol amount of tagged digest was readily performed with the CLC system. By using derivatization and fluorescence detection, the sensitivity of peptide mapping could be improved 2000 times compared to that observed with uv detection of untagged peptides.
Collapse
Affiliation(s)
- H Liu
- Department of Chemistry, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115, USA
| | | | | |
Collapse
|