1
|
Hashemi N, Tondro Anamag F, Javan Balegh Marand A, Rahnama'i MS, Herizchi Ghadim H, Salehi-Pourmehr H, Hajebrahimi S. A systematic and comprehensive review of the role of microbiota in urinary chronic pelvic pain syndrome. Neurourol Urodyn 2024; 43:1859-1882. [PMID: 38994675 DOI: 10.1002/nau.25550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Revised: 03/21/2024] [Accepted: 06/28/2024] [Indexed: 07/13/2024]
Abstract
BACKGROUND Many genitourinary tract disorders could be attributed partly to the microbiota. This study sought to conduct a systematic review of the role of the microbiota in urinary chronic pelvic pain syndrome (UCPPS). METHODS We searched Embase, Scopus, Web of Science, and PubMed with no time, language, or study type restrictions until December 1, 2023. The JBI Appraisal Tool was used to assess the quality of the studies. Study selection followed the PRISMA statement. Studies addressing microbiome variations among patients suffering from interstitial cystitis/bladder pain syndrome (IC/BPS) or chronic prostatitis/chronic pelvic pain syndrome (CP/CPPS) and a control group were considered eligible. RESULTS A total of 21 studies (1 UCPPS, 12 IC/BPS, and 8 CP/CPPS) comprising 1125 patients were enrolled in our final data synthesis. It has been shown that the reduced diversity and discrepant composition of the gut microbiota may partly be attributed to the UCPPS pathogenesis. In terms of urine microbiota, some operational taxonomic units were shown to be elevated, while others became less abundant. Furthermore, various bacteria and fungi are linked to specific clinical features. Few investigations denied UCPPS as a dysbiotic condition. CONCLUSIONS Urinary and intestinal microbiota appear to be linked with UCPPS, comprising IC/BPS and CP/CPPS. However, given the substantial disparity of published studies, a battery of prospective trials is required to corroborate these findings.
Collapse
Affiliation(s)
- Negin Hashemi
- Pharmaceutical Analysis Research Center, Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Farhad Tondro Anamag
- Research Center for Evidence-based Medicine, Iranian EBM Centre: A JBI Centre of Excellence, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | | | | | - Hanieh Salehi-Pourmehr
- Research Center for Evidence-based Medicine, Iranian EBM Centre: A JBI Centre of Excellence, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
- Medical Philosophy and History Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Sakineh Hajebrahimi
- Research Center for Evidence-based Medicine, Iranian EBM Centre: A JBI Centre of Excellence, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
- Urology Department, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
2
|
Karthikeyan R, Agri H, Yadav A, Jayakumar V, Kiranmayee B, Karikalan M, Chandra M, Lyngdoh V, Ghatak S, Sinha DK, Singh BR. A study on the occurrence of Burkholderia cepacia complex in ultrasound gels used in different veterinary clinical settings in India. Vet Res Commun 2023; 47:1413-1425. [PMID: 36914918 DOI: 10.1007/s11259-023-10091-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 02/26/2023] [Indexed: 03/14/2023]
Abstract
Burkholderia cepacia complex (Bcc) organisms are emerging multidrug-resistant pathogens. They are opportunistic and cause severe diseases in humans that may result in fatal outcomes. They are mainly reported as nosocomial pathogens, and transmission often occurs through contaminated pharmaceutical products. From 1993 to 2019, 14 Bcc outbreaks caused by contaminated ultrasound gels (USGs) have been reported in several countries, including India. We screened a total of 63 samples of USGs from various veterinary and human clinical care centers across 17 states of India and isolated 32 Bcc strains of Burkholderia cenocepacia (46.8%), B. cepacia (31.3%), B. pseudomultivorans (18.8%) and B. contaminans (3.1%) species. Some isolates were co-existent in a single ultrasound gel sample. The isolation from unopened gel bottles revealed the intrinsic contamination from manufacturing sites. The MALDI-TOF analysis to identify the Bcc at the species level was supported by the partial sequencing of the recA gene for accurate species identification. The phylogenetic analysis revealed that isolates shared clades with human clinical isolates, which is an important situation because of the possible infections of Bcc by USGs both in humans and animals. The pulsed field gel electrophoresis (PFGE) typing identified the genetic variation among the Bcc isolates present in the USGs. The findings indicated USGs as the potential source of Bcc species.
Collapse
Affiliation(s)
- Ravichandran Karthikeyan
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Himani Agri
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Akanksha Yadav
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Varsha Jayakumar
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Bhimavarapu Kiranmayee
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Mathesh Karikalan
- Center for wildlife Conservation Management and Disease Surveillance, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Mudit Chandra
- Department of Veterinary Microbiology, College of Veterinary Science, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, Punjab, India
| | - Vanita Lyngdoh
- Division of Animal and Fisheries Sciences, ICAR Research Complex for NEH Region, Umiam, Meghalaya, India
| | - Sandeep Ghatak
- Division of Animal and Fisheries Sciences, ICAR Research Complex for NEH Region, Umiam, Meghalaya, India
| | - Dharmendra K Sinha
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Bhoj R Singh
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India.
| |
Collapse
|
3
|
Adanu KK, Iroko D, Amegan-Aho K, Adedia D, Ndudiri OV, Ali MA, Oyortey MA, Kpodonu J. Comparing the effectiveness and lubricity of a novel Shea lubricant to 2% lidocaine gel for digital rectal examination: a randomized non-inferiority trial. Sci Rep 2023; 13:4666. [PMID: 36949085 PMCID: PMC10033511 DOI: 10.1038/s41598-023-31555-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Accepted: 03/14/2023] [Indexed: 03/24/2023] Open
Abstract
This study compared the level of lubricity and pain reduction of a novel shea lubricant to 2% lidocaine gel during digital rectal examination (DRE). Our research group performed a 9-week single-blind non-inferiority trial at the Ho Teaching Hospital involving 153 patients. The primary outcome measure was the mean pain difference during the procedure using a Visual Analogue Scale. 75 and 78 patients were randomized to the shea lubricant and 2% lidocaine gel groups respectively. The analysis considered the per-protocol population. The mean pain difference at endpoint was Δ - 0.01. The 95% lower confidence interval was a -0.595 difference in means, above the non-inferiority (NI) limit of - 0.720, thus establishing non-inferiority (Δ - 0.01, 95% CI - 0.59 to 0.57, NI - 0.72). With secondary outcome measures, perianal pruritus (p = 0.728), discomfort (p = 0.446), bowel urgency (p = 0.077) and urinary urgency (p = 0.841) were similar during the procedure. Shea lubricant had better lubricity and ease of use (p = 0.002). While the novel shea lubricant achieved similar level of pain reduction as obtained with 2% lidocaine gel, it had better ease of performance and lubricity.
Collapse
Affiliation(s)
- Kekeli Kodjo Adanu
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana.
| | - Davidson Iroko
- Department of Anaesthesia and Critical Care, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Kokou Amegan-Aho
- Department of Pediatrics, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - David Adedia
- Department of Basic Sciences, School of Basic and Biomedical Sciences, University of Health and Allied Sciences, Ho, Ghana
| | - Orish Verner Ndudiri
- Department of Microbiology, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Mahamudu Ayamba Ali
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | - Mawuenyo Attawa Oyortey
- Department of Surgery, School of Medicine, University of Health and Allied Sciences, Ho, Ghana
| | | |
Collapse
|
4
|
Hudson MJ, Park SC, Mathers A, Parikh H, Glowicz J, Dar D, Nabili M, LiPuma JJ, Bumford A, Pettengill MA, Sterner MR, Paoline J, Tressler S, Peritz T, Gould J, Hutter SR, Moulton-Meissner H, Perkins KM. Outbreak of Burkholderia stabilis Infections Associated with Contaminated Nonsterile, Multiuse Ultrasound Gel - 10 States, May-September 2021. MMWR. MORBIDITY AND MORTALITY WEEKLY REPORT 2022; 71:1517-1521. [PMID: 36454695 PMCID: PMC9721143 DOI: 10.15585/mmwr.mm7148a3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
Abstract
In July 2021, the Virginia Department of Health notified CDC of a cluster of eight invasive infections with Burkholderia stabilis, a bacterium in the Burkholderia cepacia complex (BCC), among hospitalized patients at hospital A. Most patients had undergone ultrasound-guided procedures during their admission. Culture of MediChoice M500812 nonsterile ultrasound gel used in hospital A revealed contamination of unopened product with B. stabilis that matched the whole genome sequencing (WGS) of B. stabilis strains found among patients. CDC and hospital A, in collaboration with partner health care facilities, state and local health departments, and the Food and Drug Administration (FDA), identified 119 B. stabilis infections in 10 U.S. states, leading to the national recall of all ultrasound gel products produced by Eco-Med Pharmaceutical (Eco-Med), the manufacturer of MediChoice M500812. Additional investigation of health care facility practices revealed frequent use of nonsterile ultrasound gel to assist with visualization in preparation for or during invasive, percutaneous procedures (e.g., intravenous catheter insertion). This practice could have allowed introduction of contaminated ultrasound gel into sterile body sites when gel and associated viable bacteria were not completely removed from skin, leading to invasive infections. This outbreak highlights the importance of appropriate use of ultrasound gel within health care settings to help prevent patient infections, including the use of only sterile, single-use ultrasound gel for ultrasonography when subsequent percutaneous procedures might be performed.
Collapse
|
5
|
Angrup A, Kanaujia R, Biswal M, Ray P. Systematic review of ultrasound gel associated Burkholderia cepacia complex outbreaks: Clinical presentation, sources and control of outbreak. Am J Infect Control 2022; 50:1253-1257. [PMID: 35158013 DOI: 10.1016/j.ajic.2022.02.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 01/30/2022] [Accepted: 02/01/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Burkholderia cepacia complex (Bcc) is an emerging opportunistic pathogen among immunocompromised patients. It frequently contaminates saline, fluids and ultrasound (US) gel used in hospitals. This systematic review was conducted to analyze Bcc outbreaks due to ultrasound (US) gel for better management of these outbreaks. METHODS As per PRISMA guidelines, electronic databases "Embase" and "Pubmed" and "Web of sciences" were searched from 1991 to April, 2021 to identify studies causing Burkholderia spp outbreak due to contamination of US gels. RESULTS The search identified 14 outbreak reports that met our inclusion criteria. Bacteremia was the most common clinical presentation in ten studies followed by urinary tract infections in 4 studies. In most of the studies B. cepacia was the most common isolated organism. Other members like B. ambifaria, B. contaminans, and B. stabilis caused outbreaks in two studies. Pulsed field gel electrophoresis and multilocus sequence typing were commonly employed methods to study the clonal association. In 8 outbreaks, intrinsic contamination of the gel, that is, contamination from manufacturing site, was present and 4 studies, extrinsic contamination, that is, contamination from environment was responsible for outbreak. CONCLUSION This review highlights the importance of US gel as a source of outbreak in health-care facilities. Ensuring sterility of US gel, sound epidemiological investigation of outbreak and prompt response by infection control team can prevent these outbreaks.
Collapse
Affiliation(s)
- Archana Angrup
- Department of Medical Microbiology, PGIMER, Chandigarh, India
| | | | - Manisha Biswal
- Department of Medical Microbiology, PGIMER, Chandigarh, India.
| | - Pallab Ray
- Department of Medical Microbiology, PGIMER, Chandigarh, India
| |
Collapse
|
6
|
Mullins K, Burnham K, Henricson EK, Cohen S, Fair J, Ray JW. Identification and Analysis of Bacterial Contamination of Ultrasound Transducers and Multiuse Ultrasound Transmission Gel Bottle Tips Before and After the Aseptic Cleansing Technique. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:1957-1963. [PMID: 32339352 DOI: 10.1002/jum.15300] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/14/2020] [Accepted: 03/22/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To provide a descriptive analysis for species identification of culture and Gram stain results from ultrasound transducers and multiuse ultrasound transmission gel bottle tips in active clinical use and to compare bacterial cultures from ultrasound transducers before and after aseptic cleansing. METHODS A prospective blinded descriptive analytic study of 18 distinct clinical care sites within a single primary clinical institution was conducted. Before and after a disinfectant towel cleanse, transducers were pressed against tryptic soy agar contact plates. Plates were deidentified and submitted for blind incubation, Gram staining, and species identification with microsequencing. Results were classified as clinically relevant (CR) or non-clinically relevant. In total, 188 samples were analyzed: 80 from ultrasound transducers before and cleansing, 13 from multiuse gel bottle tips before and after cleansing, and 2 precleansing samples from the data collector's pen and badge. RESULTS Fifty-nine precleansing samples (73.8%) grew cultures with CR bacteria, and 21 samples (26.3%) did not. Staphylococcus simulans represented 31.0% of all positive culture samples. Thirteen postcleansing samples (16.3%) grew cultures with CR bacteria, equating to a 78.0% reduction of CR bacterial growth (likelihood ratio, 57.10; P < .001). CONCLUSIONS Ultrasound transducers have a notable CR bacterial burden and may serve as potential infective vectors. Aseptic cleansing effectively eliminates most of the bacterial load from ultrasound transducers, but some bacteria persist, presenting a risk of nosocomial infection with ultrasound-guided interventions. These findings support American Institute of Ultrasound in Medicine 2018 guidelines intended to ensure an appropriate level of transducer preparation based on the examination type while emphasizing rational infection control measures to minimize the risk of potential patient harm.
Collapse
Affiliation(s)
- Kevin Mullins
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Kevin Burnham
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Erik K Henricson
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Stuart Cohen
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - James Fair
- Department of Surgery, Division of Emergency Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Jeremiah W Ray
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| |
Collapse
|
7
|
Zou Q, Li N, Liu J, Li X, Wang Z, Ai X, Tao F, Qu M, Cai M, Hu Y. Investigation of an outbreak of Burkholderia cepacia infection caused by drug contamination in a tertiary hospital in China. Am J Infect Control 2020; 48:199-203. [PMID: 31345617 DOI: 10.1016/j.ajic.2019.06.011] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2019] [Revised: 06/10/2019] [Accepted: 06/11/2019] [Indexed: 01/23/2023]
Abstract
BACKGROUND Contamination of drugs used in minimally invasive treatment may to lead to infection outbreaks and catastrophic public health events that require prompt detection and control. Our aim was to investigate the outbreak of Burkholderia cepacia infection and its source in a tertiary care, general hospital in Beijing, China. METHODS We investigated the outbreak of B cepacia infection from January 2017 to March 2018. The investigation included a detailed review of all cases, and field investigations. Environmental and product cultures were performed at the microbiology laboratory in the hospital. Isolates were evaluated for molecular relatedness using pulsed-field gel electrophoresis performed in an independent laboratory. RESULTS In total, 9 patients were infected from November 2017 to March 2018, and all patients had undergone the following surgeries: transurethral resection of the prostate (n = 4), perineal prostate biopsy (n = 2), transurethral resection of bladder tumors (n = 2), and ureteroscopy (n = 1). B cepacia was isolated from the urine of 9 patients, blood of 2 patients, grilles used for puncturing, and 2 samples in 1 batch of analgesic gels. Pulsed-field gel electrophoresis confirmed that the isolates from the patients and gels were homologous. CONCLUSIONS Our investigation revealed that the outbreak of B cepacia infection was caused by drug contamination.
Collapse
|
8
|
Abstract
CFTR protein malfunction results in thick, copious mucus, causes poor mucociliary clearance and, ultimately, structural lung damage such as bronchiectasis. All of these manifestations of cystic fibrosis contribute to a rich milieu for lower respiratory pathogens in patients affected by the disease. CF patients are, therefore, highly susceptible to chronic colonization with many pathogens such as Staphylococcus aureus and Pseudomonas aeruginosa. They are also uniquely prone to acute infections with respiratory pathogens, which tend to persist longer and cause more impairment in lung function than in patients without CF. Tailored strategies for managing infectious complications of CF patients include chronic prophylactic antibiotics, use of systemic as well as inhaled antibiotics, mechanical assistance with mucus clearance, and scrupulous infection control measures.
Collapse
|
9
|
Ilyas F, Burbridge B, Babyn P. Health Care-Associated Infections and the Radiology Department. J Med Imaging Radiat Sci 2019; 50:596-606.e1. [PMID: 31623975 PMCID: PMC7104925 DOI: 10.1016/j.jmir.2019.07.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2017] [Revised: 07/01/2019] [Accepted: 07/29/2019] [Indexed: 12/12/2022]
Abstract
Health care-associated infections (HCAIs) are a significant concern for both health care workers (HCWs) and patients. They are a major contributing factor of disease in industrialized countries, and are responsible for significant morbidity, mortality, and a direct annual financial loss of $6-7 billion in North America alone. They are an increasingly challenging health issue due to multidrug-resistant pathogens such as methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococci among others, along with an increasing number of susceptible patients. Over the last three decades, the risk of HCAIs has increased in the radiology department (RD) in part because of an increased number of patients visiting the department and an increase in the utilization of imaging modalities. In this review, we will discuss how patients and staff can be exposed to HCAIs in the RD, including contaminated inanimate surfaces, radiology equipment, and associated medical devices. As the role of medical imaging has extended from primarily diagnosis to include more interventions, the implementation and development of standardized infection minimization protocols and infection control procedures are vital in the RD, particularly in interventional radiology. With globalisation and the rapid movement of people regionally, nationally, and globally, there is greater risk of exposure to contagious diseases such as Ebola, especially if infected patients are undiagnosed when they travel. For effective infection control, advanced training and education of HCWs in the RD is essential. The purpose of this article is to provide an overview of HCAIs as related to activities of the RD. We will discuss the following major topics including the variety of HCAIs commonly encountered, the role of the RD in HCAIs, transmission of infections to patients and HCWs in the RD, standard infection prevention measures, and the management of susceptible/infected patients in the RD. We shall also examine the role of, and the preparedness of, HCWs, including RD technologists and interventional radiologists, who may be exposed to undiagnosed, yet infected patients. We shall conclude with a brief discussion of the role of further research related to HCAIs. Learning Objectives After the completion of this review article, the readers will • Understand the exposure and role of radiology department in health care-associated infections, • Know the causes/modes/transmission of infections in radiology department, • Be conscious of standard disinfection protocols, • Be aware of current and future strategies required for the effective control of health care-associated infection in the radiology department. This is a CME article and provides the equivalent of 2 hours of continuing education that may be applied to your professional development credit system. A 10-question multiple-choice quiz follows this reading. Please note that no formalized credit (category A) is available from CAMRT.
Collapse
Affiliation(s)
- Fatima Ilyas
- Department of Medical Imaging, University of Saskatchewan, Royal University Hospital, 103 Hospital Drive, Saskatoon, Saskatchewan, Canada.
| | | | | |
Collapse
|
10
|
Williams GW, Cai C, Artime CA, Teima D, Emerald A, Rajkumar KP. Evaluation of saline versus gel as contact medium for ultrasonographic image quality. JOURNAL OF CLINICAL ULTRASOUND : JCU 2019; 47:540-545. [PMID: 31206707 DOI: 10.1002/jcu.22750] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2019] [Revised: 04/29/2019] [Accepted: 05/27/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVES Evaluate the time taken to visualize the internal jugular vein and carotid arteries, and subjective image quality assessed on a 0-100 visual analogic scale, on an ultrasound model using either traditional ultrasound gel or normal saline. METHODS Twenty-two anesthesiology residents and twenty anesthesiology faculty were blinded and randomized into four separate groups using gel and saline as a conduction medium, in different sequences. RESULTS Subjective image quality was 12.2 ± 4.2 better with gel than with saline (P < 0.01). Image acquisition time did not differ significantly between the two mediums. There was no significant difference in subjective image quality or time to image acquisition between faculty and residents. CONCLUSIONS Internal jugular vein and carotid artery identification time using ultrasonography were similar between gel and saline as conduction mediums. The difference in subjective image quality did not appear clinically relevant. Better image quality resulted in less time taken to identify the structures, as expected. We conclude that saline may be an effective alternative medium to gel for vessel imaging and access guidance. Further study in a clinical setting is warranted.
Collapse
Affiliation(s)
| | - Chunyan Cai
- Division of Clinical and Translational Sciences, Department of Internal Medicine, McGovern Medical School at UTHealth, Houston, Texas
| | | | - Dalia Teima
- Department of Anesthesiology, McGovern Medical School at UTHealth, Houston, Texas
| | | | | |
Collapse
|
11
|
Juárez-Jiménez B, Pesciaroli C, Maza-Márquez P, López-Martínez S, Vílchez-Quero JL, Zafra-Gómez A. Biodegradation of methyl and butylparaben by bacterial strains isolated from amended and non-amended agricultural soil. Identification, behavior and enzyme activities of microorganisms. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2019; 245:245-254. [PMID: 31154171 DOI: 10.1016/j.jenvman.2019.05.122] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/26/2019] [Revised: 05/17/2019] [Accepted: 05/26/2019] [Indexed: 06/09/2023]
Abstract
The aim of the present study was to investigate the kinetics of methylparaben (MPB) and butylparaben (BPB) removal, two emerging pollutants with possible endocrine disrupting effects, from agricultural soil with and without amendment with compost from sewage sludge used as biostimulant. Compound removal is explained by a first-order kinetic model with half-life times of 6.5/6.7 days and 11.4/8.2 days, in presence/absence of compost, for MPB and BPB respectively. % R2 for the fitted model were higher than 96% in all cases. Additionally, isolation of bacteria capable to grow using MPB or BPB as carbon source was also carry out. Laboratory tests demonstrated the ability of these bacteria to biodegrade MPB and BPB from culture media in more than 95% in some cases. These strains showed high ability to biodegrade the compounds. Ten isolates, most of them related to Gram positive bacteria of the genus Bacillus, were identified by 16S rRNA gene sequencing. The study of the enzymatic activities of the isolates revealed both esterase (C4) and esterase-lipase activities.
Collapse
Affiliation(s)
- Belén Juárez-Jiménez
- Research Group of Environmental Microbiology, Department of Microbiology, Faculty of Pharmacy, Campus of Cartuja, And Water Institute, C/ Ramon y Cajal s/n, University of Granada, E-18071, Granada, Spain.
| | - Chiara Pesciaroli
- Department of Biotechnology and Bioscience, University of Milan Bicocca, Italy
| | - Paula Maza-Márquez
- Research Group of Environmental Microbiology, Department of Microbiology, Faculty of Pharmacy, Campus of Cartuja, And Water Institute, C/ Ramon y Cajal s/n, University of Granada, E-18071, Granada, Spain
| | - Sergio López-Martínez
- Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071, Granada, Spain
| | - José Luís Vílchez-Quero
- Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071, Granada, Spain
| | - Alberto Zafra-Gómez
- Research Group of Analytical Chemistry and Life Sciences, Department of Analytical Chemistry, University of Granada, Campus of Fuentenueva, E-18071, Granada, Spain.
| |
Collapse
|
12
|
Yagnik KJ, Kalyatanda G, Cannella AP, Archibald LK. Outbreak of Acinetobacter baumannii associated with extrinsic contamination of ultrasound gel in a tertiary centre burn unit. Infect Prev Pract 2019; 1:100009. [PMID: 34368675 PMCID: PMC8336045 DOI: 10.1016/j.infpip.2019.100009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 06/20/2019] [Indexed: 11/28/2022] Open
Abstract
Background During 2011 and 2012, an increase in occurrence of multidrug-resistant Acinetobacter baumannii infections was recorded in the Shands Hospital Burn Intensive Care Unit (BICU). An epidemic curve together with strain typing was consistent with an intermittent common source outbreak. An investigation was therefore initiated. Aim To identify risk factors for A. baumannii infection, characterize the source of the pathogen, implement control measures to terminate the outbreak, and institute preventive measures. Methods We conducted a retrospective case-control study; reviewed BICU infection control policies, practices and procedures, and patient exposure to healthcare workers (HCWs), and obtained epidemiologically-directed environmental cultures. Findings Eleven patients met the case definition. On multivariate analysis, case-patients were more likely to have undergone an ultrasound procedure in the BICU (adjusted odds ratio [AOR]: 19.5; confidence interval [CI]: 2.4-435) or have a FlexiSeal™ device (AOR: 11.9, CI:1.3-276). Epidemiologically-directed cultures of the environment, ultrasound equipment, and ultrasound gel from opened containers on the ultrasound trolley and in the Ultrasound Department were negative for the outbreak pathogen. Culture of an open ultrasound gel dispenser stored in the Ultrasound Department yielded an A. baumannii strain with DNA banding patterns identical to the outbreak strain. Conclusions Based on data from our epidemiologic, microbiologic, and observational studies, we believe that inadvertent extrinsic contamination of the gel dispenser occurred in the Ultrasound Department. Contaminated gel was then dispensed into multiuse vials of gel stored on the mobile carts. The outbreak was stemmed by instituting changes in practices in the Ultrasound Department, including introduction of single-use ultrasound vials and storage of ultrasound gel.
Collapse
Affiliation(s)
- Kruti J Yagnik
- University of Florida College of Medicine, Department of Medicine, Gainesville, FL, USA
| | - Gautam Kalyatanda
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA
| | - Anthony P Cannella
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA.,University of Florida College of Medicine, Department of Molecular Genetics & Microbiology, Gainesville, FL, USA.,University of Florida College of Medicine, Emerging Pathogens Institute, Gainesville, FL, USA
| | - Lennox K Archibald
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA
| |
Collapse
|
13
|
Incidence of residual bacterial contamination of transvaginal ultrasound probes. J Med Ultrason (2001) 2019; 46:475-479. [DOI: 10.1007/s10396-019-00941-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 03/08/2019] [Indexed: 10/27/2022]
|
14
|
Solaimalai D, Devanga Ragupathi NK, Ranjini K, Paul H, Verghese VP, Michael JS, Veeraraghavan B, James EJ. Ultrasound gel as a source of hospital outbreaks: Indian experience and literature review. Indian J Med Microbiol 2019; 37:263-267. [PMID: 31745029 DOI: 10.4103/ijmm.ijmm_19_249] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Purpose Hospital outbreaks are observed increasingly worldwide with various organisms from different sources such as contaminated ultrasound gel, intravenous (IV) fluids and IV medications. Among these, ultrasound gel is one of the most commonly reported sources for Burkholderia cepacia complex (Bcc) outbreaks. In this study, we describe our experience on investigation and the management of Bcc bacteraemia outbreak due to contaminated ultrasound gel from a tertiary care centre, South India. Materials and Methods Over a 10-day period in October 2016, seven children in our Paediatric intensive care unit (ICU) were found to have bacteraemia with Bcc isolated from their blood culture. Repeated isolation of the same organism with similar antimicrobial susceptibility pattern over a short incubation period from the same location, confirmed the outbreak. An active outbreak investigation, including environmental surveillance, was carried out to find the source and control the outbreak. Isolates were subjected to multi-locus sequence typing (MLST) and global eBURST (goeBURST) analysis. Results Environmental surveillance revealed contaminated ultrasound gel as the source of infection. MLST and goeBURST analysis confirmed that the outbreak was caused by a novel sequence type 1362 with the same clonal complex CC517. The outbreak was controlled by stringent infection control measures, withdrawal of contaminated ultrasound gel from regular usage and implementing the practice of using ultrasonogram (USG) probe cover for USG screening and guided procedures. Conclusion This report highlights the importance of early identification of an outbreak, prompt response of the ICU and infection control teams, sound environmental and epidemiological surveillance methods to identify the source and stringent infection control measures to control the outbreak. Contaminated ultrasound gel can be a potential source for healthcare-associated infection, which cannot be overlooked.
Collapse
Affiliation(s)
| | | | - Kala Ranjini
- Department of Child Health, Christian Medical College, Vellore, Tamil Nadu, India
| | - Hema Paul
- Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Valsan P Verghese
- Department of Child Health; Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Joy Sarojini Michael
- Department of Clinical Microbiology; Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Balaji Veeraraghavan
- Department of Clinical Microbiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Ebor Jacob James
- Department of Child Health, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
15
|
Westerway SC, Basseal JM, Abramowicz JS. Medical Ultrasound Disinfection and Hygiene Practices: WFUMB Global Survey Results. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:344-352. [PMID: 30409470 DOI: 10.1016/j.ultrasmedbio.2018.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 09/19/2018] [Accepted: 09/19/2018] [Indexed: 06/08/2023]
Abstract
As ultrasound technology rapidly evolves and is used more frequently in every area of medical diagnosis and treatment, it may be overlooked as a potential vector in the transmission of a health care-associated infection. A survey on disinfection and hygiene practice in medical ultrasound was disseminated via the World Federation for Ultrasound in Medicine and Biology (WFUMB) to its six member federations and associated ultrasound societies globally. One thousand twenty-nine responses were obtained across a broad range of ultrasound practitioners. A total of 76% of respondents used transducer covers every time to scan open wounds and 71% when blood and bodily fluids were present or for an interventional procedure. Approved high-level disinfectants are not always used, even when blood comes into contact with the transducer or after endocavity scans. Alcohol-based wipes were used by many respondents to clean both external transducers and endocavity transducers. Open-ended responses indicated that a large caseload hindered the time required for cleaning and that access to clear guidelines would be beneficial. Global survey results indicate that some users do not comply with disinfection practice, and there is a gap in knowledge on basic infection prevention and control education within the ultrasound unit. As the infectious status of a patient is not often disclosed prior to an ultrasound examination, training in suitable protocols for the cleaning and disinfection of ultrasound equipment is imperative to mitigate the risk of potential infection.
Collapse
Affiliation(s)
- Susan Campbell Westerway
- Department of Dentistry and Health Sciences, Charles Sturt University, New South Wales, Australia; World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA
| | - Jocelyne M Basseal
- Australasian Society for Ultrasound in Medicine, Chatswood, New South Wales, Australia.
| | - Jacques S Abramowicz
- World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA; Department of Obstetrics & Gynecology, University of Chicago, Chicago, Illinois, USA
| |
Collapse
|
16
|
Abstract
Biocides and formulated biocides are used worldwide for an increasing number of applications despite tightening regulations in Europe and in the United States. One concern is that such intense usage of biocides could lead to increased bacterial resistance to a product and cross-resistance to unrelated antimicrobials including chemotherapeutic antibiotics. Evidence to justify such a concern comes mostly from the use of health care-relevant bacterial isolates, although the number of studies of the resistance characteristics of veterinary isolates to biocides have increased the past few years. One problem remains the definition of "resistance" and how to measure resistance to a biocide. This has yet to be addressed globally, although the measurement of resistance is becoming more pressing, with regulators both in Europe and in the United States demanding that manufacturers provide evidence that their biocidal products will not impact on bacterial resistance. Alongside in vitro evidence of potential antimicrobial cross-resistance following biocide exposure, our understanding of the mechanisms of bacterial resistance and, more recently, our understanding of the effect of biocides to induce a mechanism(s) of resistance in bacteria has improved. This article aims to provide an understanding of the development of antimicrobial resistance in bacteria following a biocide exposure. The sections provide evidence of the occurrence of bacterial resistance and its mechanisms of action and debate how to measure bacterial resistance to biocides. Examples pertinent to the veterinary field are used where appropriate.
Collapse
|
17
|
Outbreak of Burkholderia cepacia bacteraemia in a tertiary care centre due to contaminated ultrasound probe gel. J Hosp Infect 2018; 100:e257-e258. [DOI: 10.1016/j.jhin.2018.04.014] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2018] [Accepted: 04/13/2018] [Indexed: 11/24/2022]
|
18
|
Glowicz J, Crist M, Gould C, Moulton-Meissner H, Noble-Wang J, de Man TJ, Perry KA, Miller Z, Yang WC, Langille S, Ross J, Garcia B, Kim J, Epson E, Black S, Pacilli M, LiPuma JJ, Fagan R. A multistate investigation of health care-associated Burkholderia cepacia complex infections related to liquid docusate sodium contamination, January-October 2016. Am J Infect Control 2018; 46:649-655. [PMID: 29329922 DOI: 10.1016/j.ajic.2017.11.018] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2017] [Revised: 11/21/2017] [Accepted: 11/22/2017] [Indexed: 11/24/2022]
Abstract
BACKGROUND Outbreaks of health care-associated infections (HAIs) caused by Burkholderia cepacia complex (Bcc) have been associated with medical devices and water-based products. Water is the most common raw ingredient in nonsterile liquid drugs, and the significance of organisms recovered from microbiologic testing during manufacturing is assessed using a risk-based approach. This incident demonstrates that lapses in manufacturing practices and quality control of nonsterile liquid drugs can have serious unintended consequences. METHODS An epidemiologic and laboratory investigation of clusters of Bcc HAIs that occurred among critically ill, hospitalized, adult and pediatric patients was performed between January 1, 2016, and October 31, 2016. RESULTS One hundred and eight case patients with Bcc infections at a variety of body sites were identified in 12 states. Two distinct strains of Bcc were obtained from patient clinical cultures. These strains were found to be indistinguishable or closely related to 2 strains of Bcc obtained from cultures of water used in the production of liquid docusate, and product that had been released to the market by manufacturer X. CONCLUSIONS This investigation highlights the ability of bacteria present in nonsterile, liquid drugs to cause infections or colonization among susceptible patients. Prompt reporting and thorough investigation of potentially related infections may assist public health officials in identifying and removing contaminated products from the market when lapses in manufacturing occur.
Collapse
|
19
|
Haviari S, Cassier P, Dananché C, Hulin M, Dauwalder O, Rouvière O, Bertrand X, Perraud M, Bénet T, Vanhems P. Outbreak of Achromobacter xylosoxidans and Ochrobactrum anthropi Infections after Prostate Biopsies, France, 2014. Emerg Infect Dis 2018; 22:1412-9. [PMID: 27434277 PMCID: PMC4982167 DOI: 10.3201/eid2208.151423] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
We report an outbreak of healthcare-associated prostatitis involving rare environmental pathogens in immunocompetent patients undergoing transrectal prostate biopsies at Hôpital Édouard Herriot (Lyon, France) during August 13-October 10, 2014. Despite a fluoroquinolone-based prophylaxis, 5 patients were infected with Achromobacter xylosoxidans and 3 with Ochrobactrum anthropi, which has not been reported as pathogenic in nonimmunocompromised persons. All patients recovered fully. Analysis of the outbreak included case investigation, case-control study, biopsy procedure review, microbiologic testing of environmental and clinical samples, and retrospective review of hospital records for 4 years before the outbreak. The cases resulted from asepsis errors during preparation of materials for the biopsies. A low-level outbreak involving environmental bacteria was likely present for years, masked by antimicrobial drug prophylaxis and a low number of cases. Healthcare personnel should promptly report unusual pathogens in immunocompetent patients to infection control units, and guidelines should explicitly mention asepsis during materials preparation.
Collapse
|
20
|
Nyhsen CM, Humphreys H, Koerner RJ, Grenier N, Brady A, Sidhu P, Nicolau C, Mostbeck G, D’Onofrio M, Gangi A, Claudon M. Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group. Insights Imaging 2017; 8:523-535. [PMID: 29181694 PMCID: PMC5707224 DOI: 10.1007/s13244-017-0580-3] [Citation(s) in RCA: 58] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 10/03/2017] [Accepted: 10/05/2017] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES The objective of these recommendations is to highlight the importance of infection prevention and control in ultrasound (US), including diagnostic and interventional settings. METHODS Review of available publications and discussion within a multidisciplinary group consistent of radiologists and microbiologists, in consultation with European patient and industry representatives. RECOMMENDATIONS Good basic hygiene standards are essential. All US equipment must be approved prior to first use, including hand held devices. Any equipment in direct patient contact must be cleaned and disinfected prior to first use and after every examination. Regular deep cleaning of the entire US machine and environment should be undertaken. Faulty transducers should not be used. As outlined in presented flowcharts, low level disinfection is sufficient for standard US on intact skin. For all other minor and major interventional procedures as well as all endo-cavity US, high level disinfection is mandatory. Dedicated transducer covers must be used when transducers are in contact with mucous membranes or body fluids and sterile gel should be used inside and outside covers. CONCLUSIONS Good standards of basic hygiene and thorough decontamination of all US equipment as well as appropriate use of US gel and transducer covers are essential to keep patients safe. MAIN MESSAGES • Transducers must be cleaned/disinfected before first use and after every examination. • Low level disinfection is sufficient for standard US on intact skin. • High level disinfection is mandatory for endo-cavity US and all interventions. • Dedicated transducer covers must be used for endo-cavity US and all interventions. • Sterile gel should be used for all endo-cavity US and all interventions.
Collapse
Affiliation(s)
- Christiane M. Nyhsen
- Radiology Department, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Hilary Humphreys
- Department of Clinical Microbiology, The Royal College of Surgeons in Ireland, Dublin, Ireland
- Department of Microbiology, Beaumont Hospital, Dublin, Ireland
| | - Roland J. Koerner
- Infection Prevention and Control Department, Department of Microbiology, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Nicolas Grenier
- Service d’Imagerie Diagnostique et Interventionnelle de l’Adulte Groupe Hospitalier, Pellegrin Place Amelie Raba-Leon, 33076 Bordeaux, Cedex France
| | - Adrian Brady
- Department of Radiology, Mercy University Hospital, Grenville Place, Cork, T12 WE28 Ireland
| | - Paul Sidhu
- King’s College Hospital, Denmark Hill, London, SE5 9RS UK
| | | | | | - Mirko D’Onofrio
- Radiology, Policlinico G.B. Rossi, VERONA, piazzale LA SCURO 10, 37134 Verona, Italy
| | - Afshin Gangi
- NHC, 1, Place de l’Hôpital, 67091 Strasbourg, France
| | - Michel Claudon
- Children Hospital, University Hospital - Nancy Brabois, Rue du Morvan, 54511 Vandoeuvre Les Nancy, Cedex France
| |
Collapse
|
21
|
Leduc P, Doublet JD, Bruyère F, Malavaud S. [Infection control practices while performing prostate biopsies in France: A CIAFU survey]. Prog Urol 2017; 27:529-535. [PMID: 28818480 DOI: 10.1016/j.purol.2017.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Revised: 05/28/2017] [Accepted: 07/05/2017] [Indexed: 10/19/2022]
Abstract
In 2008, the French Public Health Committee admitted that associating ultrasound probe protection, and related precautions, and low-level disinfection would be equivalent to the intermediate level disinfection. In 2010, the French Urology Association (AFU) updated guidelines regarding trans-rectal prostate biopsies, namely preventive measures related to cross-transmission of infections. We report an evaluation of compliance to them, driven in 2016 by AFU's infection committee. Although not recommended, almost one third of the urologists still perform biopsies under general anesthesia, and two thirds of them ask for a urine culture before biopsies. Several improvements are still needed: sterilization of needle guide should always be done when not of single use, the ultrasonography gel should be sterile, probes protection should be EC labeled, and compliance to probe processing between two patients should increase. Most of urologists happened to experience blood or feces contamination of probes. Less than half of probes are entirely floodable, and when intermediate level disinfection is done, glutaraldehyde is still referred as disinfectant by one third of the urologists. LEVEL OF EVIDENCE 4.
Collapse
Affiliation(s)
- P Leduc
- Unité d'épidémiologie et hygiène hospitalière, CHU Toulouse-Rangueil, 1, avenue Jean-Poulhès, 31059 Toulouse cedex 9, France
| | - J D Doublet
- Service d'urologie, centre hospitalier de Versailles, 177, rue de Versailles, 78157 Le Chesnaix cedex, France
| | - F Bruyère
- Service d'urologie, CHRU de Tours, 2, boulevard Tonnellé, 37044 Tours, France; PRES centre Val-de-Loire, université François-Rabelais de Tours, 37044 Tours, France
| | - S Malavaud
- Unité d'épidémiologie et hygiène hospitalière, CHU Toulouse-Rangueil, 1, avenue Jean-Poulhès, 31059 Toulouse cedex 9, France.
| | | |
Collapse
|
22
|
Fan C, Wang SC. Co-metabolic enhancement of organic removal from waste water in the presence of high levels of alkyl paraben constituents of cosmetic and personal care products. CHEMOSPHERE 2017; 179:306-315. [PMID: 28376394 DOI: 10.1016/j.chemosphere.2017.03.120] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/04/2016] [Revised: 03/27/2017] [Accepted: 03/28/2017] [Indexed: 06/07/2023]
Abstract
The enhanced removal of organic material from municipal waste water containing 50 mg/L of chemical oxygen demand and a given amount of alkyl paraben using a biofilm system was investigated. The parabens used were methyl, ethyl, and propyl paraben. The experiments were conducted at influent paraben concentrations of 10 and 50 mg/L. The influent pH was measured around 4.6 because of paraben hydrolysis. The effluent pH increased due to hydrogen consumption and small molecular acid generation. The higher removal rates were observed for the paraben with longer alkyl chains, which were more hydrophobic and capable of penetrating into microbial cells. The co-existing organic constituents in municipal waste water were found to be competitive with paraben molecules for microbial degradation at low paraben loading (i.e., 10 mg/L). Instead, the co-metabolic effect was observed at a higher paraben loading (i.e., 50 mg/L) due to more active enzymatic catalysis, implying the possible enhancement or organic removal in the presence of high levels of parabens. The difference in BOD and TOC removing ratios for parabens decreased with increasing HRT, implying their better mineralization than that of municipal organic constituents. This was because the microbial organism became more adapted to the reacting system with longer HRT, and more oxygenase was produced to facilitate the catechol formation and ring-opening reactions, causing apparent enhancement in mineralization.
Collapse
Affiliation(s)
- Chihhao Fan
- Department of Bioenvironmental Systems Engineering, National Taiwan University, Taipei, 10617, Taiwan.
| | - Shin-Chih Wang
- Geographic Information Technology Co., Ltd., Taipei, 10694, Taiwan.
| |
Collapse
|
23
|
Abstract
Colonization of the extremely preterm infant's gastrointestinal tract and skin begins in utero and is influenced by a variety of factors, the most important including gestational age and environmental exposures. The composition of the intestinal and skin microbiota influences the developing innate and adaptive immune responses with short-term and long-term consequences including altered risks for developing necrotizing enterocolitis, sepsis, and a wide variety of microbe-related diseases of children and adults. Alteration of the composition of the microbiota to decrease disease risk is particularly appealing for this ultra-high-risk cohort that is brand new from an evolutionary standpoint.
Collapse
|
24
|
JOURNAL CLUB: Ultrasound-Guided Breast Interventions: Low Incidence of Infectious Complications With Use of an Uncovered Probe. AJR Am J Roentgenol 2017; 208:1147-1153. [PMID: 28225634 DOI: 10.2214/ajr.16.16440] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the incidence of infectious complications after ultrasound-guided breast interventions performed with an intermediate-level disinfection protocol without an ultrasound probe cover. MATERIALS AND METHODS Two independent institutional databases were searched to identify breast infections in patients who underwent ultrasound-guided interventions between January 2005 and July 2013. The departments of radiology and infectious diseases independently maintained these databases. A comprehensive retrospective chart review based on periprocedural antibiotic use and clinical documentation of infection was also performed to reduce the likelihood of missing potential infectious complications. RESULTS A total of 12,708 ultrasound-guided breast procedures were performed in the time frame of this study. All potential cases of procedure-related infection were included for subspecialist review in an effort to give the most conservative (highest) estimate of infectious complications. Among these cases, 14 documented cases of possible procedure-related infection were identified, for an overall incidence of 0.11%. All infections were localized skin or soft-tissue infections and adequately treated with a short course of oral antibiotics. No cases of more serious infections or sepsis were found. None of the reported infections required IV antibiotic therapy, percutaneous intervention, surgical intervention, or hospitalization. CONCLUSION The incidence of infectious complications after an ultrasound-guided breast intervention without an ultrasound probe cover is extremely low. Physicians can use this information in the development of their disinfection protocols and to provide accurate information in counseling patients during preprocedural consultation.
Collapse
|
25
|
An Outbreak of Burkholderia cepacia Complex Infections Associated with Contaminated Liquid Docusate. Infect Control Hosp Epidemiol 2017; 38:567-573. [PMID: 28166854 DOI: 10.1017/ice.2017.11] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To investigate an outbreak of Burkholderia cepacia complex and describe the measures that revealed the source. SETTING A 629-bed, tertiary-care, pediatric hospital in Houston, Texas. PATIENTS Pediatric patients without cystic fibrosis (CF) hospitalized in the pediatric and cardiovascular intensive care units. METHODS We investigated an outbreak of B. cepacia complex from February through July 2016. Isolates were evaluated for molecular relatedness with repetitive extragenic palindromic polymerase chain reaction (rep-PCR); specific species identification and genotyping were performed at an independent laboratory. The investigation included a detailed review of all cases, direct observation of clinical practices, and respiratory surveillance cultures. Environmental and product cultures were performed at an accredited reference environmental microbiology laboratory. RESULTS Overall, 18 respiratory tract cultures, 5 blood cultures, 4 urine cultures, and 3 stool cultures were positive in 24 patients. Among the 24 patients, 17 had symptomatic infections and 7 were colonized. The median age of the patients was 22.5 months (range, 2-148 months). Rep-PCR typing showed that 21 of 24 cases represented the same strain, which was identified as a novel species within the B. cepacia complex. Product cultures of liquid docusate were positive with an identical strain of B. cepacia complex. Local and state health departments, as well as the CDC and FDA, were notified, prompting a multistate investigation. CONCLUSIONS Our investigation revealed an outbreak of a unique strain of B. cepacia complex isolated in clinical specimens from non-CF pediatric patients and from liquid docusate. This resulted in a national alert and voluntary recall by the manufacturer. Infect Control Hosp Epidemiol 2017;38:567-573.
Collapse
|
26
|
Re M, Blanco-Murcia J, Villaescusa A, De Gaspar I, de Segura IAG. Comparison of paravertebral blockade techniques with and without ultrasound guidance in calves. Am J Vet Res 2016; 77:1187-1193. [PMID: 27805442 DOI: 10.2460/ajvr.77.11.1187] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To compare the effectiveness of an ultrasound-guided paravertebral nerve blockade technique (UGPNB) with distal and proximal paravertebral nerve blockade techniques without ultrasound guidance (DPNB and PPNB, respectively) in calves. ANIMALS 4 calf cadavers and 7 healthy calves. PROCEDURES A suitable acoustic window was identified to facilitate access to the T13, L1, and L2 spinal nerves in cadavers and live calves. In cadavers, nerves were injected with dye under ultrasound guidance. In calves, the UGPNB, DPNB, and PPNB were performed in random order at 10-day intervals by injection of an anesthetic solution containing 2% lidocaine hydrochloride. Nociceptive withdrawal responses were assessed to determine the effects of the blockades. RESULTS In cadavers, nerve staining success rates (ie, ≥ 2-cm-long dye path) achieved with ultrasound guidance were 88% (T13 [ventral branch]), 75% (T13 and L1 [dorsal branches] and L1 and L2 [ventral branches]), and 38% (L2 [dorsal branch]). The nerves were each identified as a hyperechoic band in a longitudinal plane. In calves, the UGPNB, DPNB, and PPNB reduced the withdrawal response to the noxious stimulus, mainly in the dorsal-cranial, dorsal-caudal, and ventral-cranial areas of the flank. Overall, the UGPNB resulted in a better nociceptive cumulative score, administering only one half of the local anaesthetic dose, compared with findings for the DPNB and PPNB. However, time to perform the UGPNB was longer. CONCLUSIONS AND CLINICAL RELEVANCE The UGPNB evaluated may be an improved alternative to the DPNB and PPNB for provision of anesthesia for flank surgery in calves. However, effectiveness of the UGPNB should be evaluated in a clinical setting and in adult cattle.
Collapse
|
27
|
Dietrich CF, Horn R, Morf S, Chiorean L, Dong Y, Cui XW, Atkinson NSS, Jenssen C. Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound. J Thorac Dis 2016; 8:E851-E868. [PMID: 27747022 DOI: 10.21037/jtd.2016.08.49] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Central venous access has traditionally been performed on the basis of designated anatomical landmarks. However, due to patients' individual anatomy and vessel pathology and depending on individual operators' skill, this landmark approach is associated with a significant failure rate and complication risk. There is substantial evidence demonstrating significant improvement in effectiveness and safety of vascular access by realtime ultrasound (US)-guidance, as compared to the anatomical landmark-guided approach. This review comments on the evidence-based recommendations on US-guided vascular access which have been published recently within the framework of Guidelines on Interventional Ultrasound (InVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) from a clinical practice point of view.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450000, China
| | - Rudolf Horn
- Notfallstation, Kantonsspital Glarus, Glarus, Switzerland
| | - Susanne Morf
- Intensivmedizin Kantonsspital Graubünden, Chur, Switzerland
| | - Liliana Chiorean
- Department of Medical Imaging, des Cévennes Clinic, Annonay, France
| | - Yi Dong
- Translational Gastroenterology Unit, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Xin-Wu Cui
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Nathan S S Atkinson
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg, Wriezen, Germany
| |
Collapse
|
28
|
Saiman L, Siegel JD, LiPuma JJ, Brown RF, Bryson EA, Chambers MJ, Downer VS, Fliege J, Hazle LA, Jain M, Marshall BC, O’Malley C, Pattee SR, Potter-Bynoe G, Reid S, Robinson KA, Sabadosa KA, Schmidt HJ, Tullis E, Webber J, Weber DJ. Infection Prevention and Control Guideline for Cystic Fibrosis: 2013 Update. Infect Control Hosp Epidemiol 2016; 35 Suppl 1:S1-S67. [DOI: 10.1086/676882] [Citation(s) in RCA: 270] [Impact Index Per Article: 33.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The 2013 Infection Prevention and Control (IP&C) Guideline for Cystic Fibrosis (CF) was commissioned by the CF Foundation as an update of the 2003 Infection Control Guideline for CF. During the past decade, new knowledge and new challenges provided the following rationale to develop updated IP&C strategies for this unique population:1.The need to integrate relevant recommendations from evidence-based guidelines published since 2003 into IP&C practices for CF. These included guidelines from the Centers for Disease Control and Prevention (CDC)/Healthcare Infection Control Practices Advisory Committee (HICPAC), the World Health Organization (WHO), and key professional societies, including the Infectious Diseases Society of America (IDSA) and the Society for Healthcare Epidemiology of America (SHEA). During the past decade, new evidence has led to a renewed emphasis on source containment of potential pathogens and the role played by the contaminated healthcare environment in the transmission of infectious agents. Furthermore, an increased understanding of the importance of the application of implementation science, monitoring adherence, and feedback principles has been shown to increase the effectiveness of IP&C guideline recommendations.2.Experience with emerging pathogens in the non-CF population has expanded our understanding of droplet transmission of respiratory pathogens and can inform IP&C strategies for CF. These pathogens include severe acute respiratory syndrome coronavirus and the 2009 influenza A H1N1. Lessons learned about preventing transmission of methicillin-resistantStaphylococcus aureus(MRSA) and multidrug-resistant gram-negative pathogens in non-CF patient populations also can inform IP&C strategies for CF.
Collapse
|
29
|
Paul LM, Hegde A, Pai T, Shetty S, Baliga S, Shenoy S. An Outbreak of Burkholderia cepacia Bacteremia in a Neonatal Intensive Care Unit. Indian J Pediatr 2016; 83:285-8. [PMID: 26264633 DOI: 10.1007/s12098-015-1855-7] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2015] [Accepted: 07/16/2015] [Indexed: 10/23/2022]
Abstract
OBJECTIVES To identify the source of infection, to study the clinical profile and outcomes of neonates with Burkholderia septicemia and to determine the antimicrobial susceptibility patterns of the isolates. METHODS The authors describe a 3 mo outbreak of nosocomial Burkholderia cepacia bacteremia involving 12 neonates. During the outbreak, ventilator humidifier water, intravenous solutions and other possible sources were taken from the concerned neonatal intensive care units (NICUs); cultured and isolates identified by standard microbiological techniques and VITEK system. Clinical details of affected babies were also obtained to ascertain the clinical significance of the isolates. RESULTS All neonates had clinical and biochemical evidence of sepsis and the source could be tracked to intravenous solutions of 5% dextrose, normal saline (opened bottles) and continuous positive airway pressure humidifier water. Strain relatedness of the environmental isolates with the clinical isolates is likely as antibiotic susceptibility patterns were similar. CONCLUSIONS The investigations revealed the source of the nosocomial outbreak which is crucial for initiating appropriate control measures.
Collapse
Affiliation(s)
- Liz Mary Paul
- Department of Microbiology, Kasturba Medical College, Manipal University, Mangalore, India
| | - Ashwini Hegde
- Department of Microbiology, Kasturba Medical College, Manipal University, Mangalore, India.
| | - Tanvi Pai
- Department of Pediatrics, Kasturba Medical College, Manipal University, Mangalore, India
| | - Subodh Shetty
- Department of Pediatrics, Kasturba Medical College, Manipal University, Mangalore, India
| | - Shrikala Baliga
- Department of Microbiology, Kasturba Medical College, Manipal University, Mangalore, India
| | - Suchitra Shenoy
- Department of Microbiology, Kasturba Medical College, Manipal University, Mangalore, India
| |
Collapse
|
30
|
Singhal T, Shah S, Naik R. Outbreak of Burkholderia cepacia complex bacteremia in a chemotherapy day care unit due to intrinsic contamination of an antiemetic drug. Indian J Med Microbiol 2016; 33:117-9. [PMID: 25560013 DOI: 10.4103/0255-0857.148405] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
BACKGROUND In the end of 2009, a large number of patients with cancer undergoing chemotherapy at the day care unit of a private hospital in Mumbai, India developed Burkholderia cepacia complex (BCC) blood stream infection (BSI). OBJECTIVE The objectives were to identify the source of the outbreak and terminate the outbreak as rapidly as possible. MATERIALS AND METHODS All infection control protocols and processes were reviewed. Intensive training was started for all nursing staff involved in patient care. Cultures were sent from the environment (surfaces, water, air), intravenous fluids, disinfectants and antiseptics and opened/unopened medication. RESULTS A total of 13 patients with cancer with tunneled catheters were affected with BCC BSI. The isolates were of similar antimicrobial sensitivity. No significant breach of infection control protocols could be identified. Cultures from the prepared intravenous medication bags grew BCC. Subsequently, culture from unused vials of the antiemetic granisetron grew BCC, whereas those from the unopened IV fluid bag and chemotherapy medication were negative. On review, it was discovered that the outbreak started when a new brand of granisetron was introduced. The result was communicated to the manufacturer and the brand was withdrawn. There were no further cases. CONCLUSIONS This outbreak was thus linked to intrinsic contamination of medication vials. We acknowledge a delay in identifying the source as we were concentrating more on human errors in medication preparation and less on intrinsic contamination. We recommend that in an event of an outbreak, unopened vials be cultured at the outset.
Collapse
Affiliation(s)
- T Singhal
- Department of Infection Control, Kokilaben Dhirubhai Ambani Hospital and Medical Research Institute, Mumbai, Maharashtra, India
| | | | | |
Collapse
|
31
|
Nannini EC, Ponessa A, Muratori R, Marchiaro P, Ballerini V, Flynn L, Limansky AS. Polyclonal outbreak of bacteremia caused by Burkholderia cepacia complex and the presumptive role of ultrasound gel. Braz J Infect Dis 2015; 19:543-5. [PMID: 26322722 PMCID: PMC9427536 DOI: 10.1016/j.bjid.2015.06.009] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2015] [Revised: 06/27/2015] [Accepted: 06/30/2015] [Indexed: 12/01/2022] Open
Abstract
A nosocomial polyclonal outbreak associated to bacteremia caused by different Burkholderia cepacia complex (BCC) species and clones is reported. Molecular characterization identified Burkholderia stabilis, Burkholderia contaminans, and Burkholderia ambifaria among BCC isolates obtained from patients in neonatal and adult intensive care units. BCC was also isolated from an intrinsically contaminated ultrasound gel, which constituted the presumptive BCC source. Prior BCC outbreak related to contaminated ultrasound gels have been described in the setting of transrectal prostate biopsy. Outbreak caused strains and/or clones of BCC have been reported, probably because BCC are commonly found in the natural environment; most BCC species are biofilm producers, and different species may contaminate an environmental source. The finding of multiple species or clones during the analysis of nosocomial BCC cases might not be enough to reject an outbreak from a common source.
Collapse
Affiliation(s)
- Esteban C Nannini
- Division of Infectious Diseases, Sanatorio Británico, Rosario, Argentina; Division of Infectious Diseases, School of Medicine, Universidad Nacional de Rosario, Rosario, Argentina.
| | - Adriana Ponessa
- Department of Microbiology, Sanatorio Británico, Rosario, Argentina
| | - Rosa Muratori
- Division of Infectious Diseases, Sanatorio Británico, Rosario, Argentina
| | - Patricia Marchiaro
- Instituto de Biología Molecular y Celular de Rosario - CONICET, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, Argentina
| | - Viviana Ballerini
- Instituto de Biología Molecular y Celular de Rosario - CONICET, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, Argentina
| | - Luis Flynn
- Division of Infectious Diseases, Sanatorio Británico, Rosario, Argentina
| | - Adriana S Limansky
- Instituto de Biología Molecular y Celular de Rosario - CONICET, Facultad de Ciencias Bioquímicas y Farmacéuticas, Universidad Nacional de Rosario, Rosario, Argentina
| |
Collapse
|
32
|
Akpochafor M, Eze C, Adeneye S, Ajekigbe A. Assessment of ultrasound equipment as a possible source of nosocomial infection in Lagos state hospitals and radio-diagnostic centres. Radiography (Lond) 2015. [DOI: 10.1016/j.radi.2014.09.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
33
|
Dolan SA, Dowell E, LiPuma JJ, Valdez S, Chan K, James JF. An Outbreak ofBurkholderia cepaciaComplex Associated with Intrinsically Contaminated Nasal Spray. Infect Control Hosp Epidemiol 2015; 32:804-10. [DOI: 10.1086/660876] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Objective.To determine the source ofBurkholderia cepaciacomplex associated with a hospital outbreak and describe the measures taken to identify and confirm the source.Setting.A 250-bed, tertiary care pediatric hospital in Denver, Colorado.Methods.An epidemiologic investigation was used to identify possible causes for an apparent outbreak ofB. cepaciacomplex in pediatric patients who had new positive cultures with this organism from December 2003 to February 2004. Chart review, microbiology reports, surgical records, site visits, literature review, staff interviews, and cultures of common products and equipment were performed to determine a source of contamination. Random amplified polymorphic DNA and pulsed-field gel electrophoresis typing, performed by 2 independent laboratories, were used for molecular typing of patient and source isolates.Results.Five pediatric patients had new positiveB. cepaciacomplex cultures from either the sinus or the respiratory tract, and all 5 patients had prior exposure to 0.05% oxymetazoline hydrochloride Major Twice-A-Day 12-hour nasal spray (Proforma, Miami, FL). Four of the 5 patients had isolates that were identical to theB. cepaciacomplex isolates recovered from the unopened Twice-A-Day 12-hour nasal spray.Conclusions.Intrinsic contamination of Major Twice-A-Day 12-hour nasal spray withB. cepaciacomplex resulted in nosocomial transmission to 4 patients at our facility and resulted in a voluntary product recall by the manufacturer.B. cepaciacomplex species are common contaminants of an increasing variety of nonsterile medical products. Enhanced culture techniques may be useful in evaluating possible product contamination, suggesting additional measures that should be considered to assure the safety of products that may be used in high-risk patients.
Collapse
|
34
|
Bacterial Contamination of Ultrasound Probes at a Tertiary Referral University Medical Center. AJR Am J Roentgenol 2014; 203:928-32. [DOI: 10.2214/ajr.13.12407] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
35
|
O’Rourke M, Levan P, Khan T. Current Use of Ultrasound Transmission Gel for Transesophageal Echocardiogram Examinations: A Survey of Cardiothoracic Anesthesiology Fellowship Directors. J Cardiothorac Vasc Anesth 2014; 28:1208-10. [DOI: 10.1053/j.jvca.2014.02.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Indexed: 11/11/2022]
|
36
|
Investigation of current infection-control practices for ultrasound coupling gel: a survey, microbiological analysis, and examination of practice patterns. Reg Anesth Pain Med 2014; 38:415-24. [PMID: 23974866 DOI: 10.1097/aap.0b013e3182a0e12f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVES Ultrasound coupling gel may serve as a vector for the spread of bacteria and has been the causative agent for significant health care-associated infections. The purpose of this study was to document existing infection-control procedures and level of contamination present within nonsterile ultrasound gel from several clinical departments at a single institution. A second purpose was to examine the effectiveness of clinician education and manufacturer-based ultrasound additives on ultrasound gel contamination and in vitro bacterial proliferation, respectively. METHODS Compliance with Health Canada recommended infection-control policies were determined by survey. Contamination of in-use ultrasound gel bottles was determined by inspecting cultures after 72 hours of incubation. After infection-control education, a 28-day interval assessment was used to examine contamination rates in newly provided ultrasound gel. The ability of ultrasound gel containing parabens to prevent bacterial growth was examined in cultures grown with and without ultrasound gel. RESULTS Practitioners were not compliant with Health Canada recommendations, but the baseline ultrasound gel contamination rate within these departments was only 2.5%. Education in infection control did not improve the contamination rate over 28 days. Contamination was discovered in ultrasound gel supplied directly from the manufacturer. Ultrasound gel suppressed but did not prevent bacterial growth in a species- and time-specific manner. CONCLUSIONS The source of contamination for in-use ultrasound gel may be of manufacturer or human origin. Because additives to the ultrasound gel are not bactericidal, sterile ultrasound gel should be used for invasive and high-risk cases, and improving infection-control policies is warranted.
Collapse
|
37
|
M'Zali F, Bounizra C, Leroy S, Mekki Y, Quentin-Noury C, Kann M. Persistence of microbial contamination on transvaginal ultrasound probes despite low-level disinfection procedure. PLoS One 2014; 9:e93368. [PMID: 24695371 PMCID: PMC3973690 DOI: 10.1371/journal.pone.0093368] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Accepted: 03/04/2014] [Indexed: 11/18/2022] Open
Abstract
AIM OF THE STUDY In many countries, Low Level Disinfection (LLD) of covered transvaginal ultrasound probes is recommended between patients' examinations. The aim of this study was to evaluate the antimicrobial efficacy of LLD under routine conditions on a range of microorganisms. MATERIALS AND METHODS Samples were taken over a six month period in a private French Radiology Center. 300 specimens derived from endovaginal ultrasound probes were analyzed after disinfection of the probe with wipes impregnated with a quaternary ammonium compound and chlorhexidine. Human papillomavirus (HPV) was sought in the first set of s100 samples, Chlamydia trachomatis and mycoplasmas were searched in the second set of 100 samples, bacteria and fungi in the third 100 set samples. HPV, C. trachomatis and mycoplasmas were detected by PCR amplification. PCR positive samples were subjected to a nuclease treatment before an additional PCR assay to assess the likely viable microorganisms. Bacteria and fungi were investigated by conventional methods. RESULTS A substantial persistence of microorganisms was observed on the disinfected probes: HPV DNA was found on 13% of the samples and 7% in nuclease-resistant form. C. trachomatis DNA was detected on 20% of the probes by primary PCR but only 2% after nuclease treatment, while mycoplasma DNA was amplified in 8% and 4%, respectively. Commensal and/or environmental bacterial flora was present on 86% of the probes, occasionally in mixed culture, and at various levels (10->3000 CFU/probe); Staphylococcus aureus was cultured from 4% of the probes (10-560 CFU/probe). No fungi were isolated. CONCLUSION Our findings raise concerns about the efficacy of impregnated towels as a sole mean for disinfection of ultrasound probes. Although the ultrasound probes are used with disposable covers, our results highlight the potential risk of cross contamination between patients during ultrasound examination and emphasize the need for reviewing the disinfection procedure.
Collapse
Affiliation(s)
- Fatima M'Zali
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Carole Bounizra
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Sandrine Leroy
- Centre Hospitalier Universitaire de Nîmes, Service de Biostatistique, Epidémiologie Clinique, Santé Publique, Informatique Médicale, Nîmes, France
| | - Yahia Mekki
- Laboratoire de Virologie, Centre de Biologie et Pathologie Est, Hospices Civils de Lyon, Lyon, France
| | - Claudine Quentin-Noury
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| | - Michael Kann
- Université Bordeaux Segalen, Microbiologie Fondamentale et Pathogénicité Unité Mixte de Recherche 5234, Bordeaux, France
| |
Collapse
|
38
|
Lawrence MW, Blanks J, Ayala R, Talk D, Macian D, Glasser J, Schofer JM. Hospital-wide survey of bacterial contamination of point-of-care ultrasound probes and coupling gel. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2014; 33:457-462. [PMID: 24567457 DOI: 10.7863/ultra.33.3.457] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
OBJECTIVES The purpose of this study was to determine the hospital-wide incidence of bacterial contamination of point-of-care (bedside) ultrasound probes and coupling gel at a single academic medical center to predict the risk of nosocomial spread of infection. METHODS Bacterial cultures were performed on all point-of-care ultrasound probe surfaces and associated gel bottles in our institution (82 total probes in 9 separate departments). This process was repeated every 2 weeks for a total of 8 weeks; therefore, each probe was cultured 4 times during the study period. RESULTS Of the 320 probe cultures, 18 (5.6%), resulted in positive growth, all of which identified nonpathogenic organisms common to human skin flora and the environment. No methicillin-resistant Staphylococcus aureus or other notable pathogens were identified. No gel cultures resulted in bacterial growth. CONCLUSIONS Bacterial contamination of point-of-care ultrasound probes and coupling gel is low at this single academic medical center and involves nonpathogenic organisms only.
Collapse
Affiliation(s)
- Matthew W Lawrence
- LCDR, MC, USN, Emergency Department, Naval Medical Center, 2927 Bruce Station, Chesapeake, VA 23321 USA.
| | | | | | | | | | | | | |
Collapse
|
39
|
Souza Dias MB, Cavassin LG, Stempliuk V, Xavier LS, Lobo RD, Sampaio JL, Pignatari AC, Borrasca VL, Bierrenbach AL, Toscano CM. Multi-institutional outbreak of Burkholderia cepacia complex associated with contaminated mannitol solution prepared in compounding pharmacy. Am J Infect Control 2013; 41:1038-42. [PMID: 23663863 DOI: 10.1016/j.ajic.2013.01.033] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 01/17/2013] [Accepted: 01/17/2013] [Indexed: 11/26/2022]
Abstract
BACKGROUND Burkholderia cepacia complex (BCC) has been described as a cause of nosocomial outbreaks. We describe an outbreak of and identify risk factors for nosocomial BCC infections associated with intrinsically contaminated mannitol 3% solution. METHODS Urinary and bloodstream infection caused by BCC were identified in hospitalized patients who underwent urologic surgery and received intraoperative irrigation of 3% mannitol solution in February 2009. The investigation included retrospective chart review, case control study, procedural review, and culture of mannitol solution. RESULTS Seven BCC infections were identified. BCC isolates were recovered from blood and/or urine from patients and lots of mannitol in use during the outbreak period. Mannitol solution was produced by a compounding pharmacy. Receipt of larger volumes of contaminated solution was identified as a significant risk factor for infection (odds ratio, 1.5; P value < .05). BCC was also cultured in lots of mannitol in use in other hospitals. CONCLUSION Manipulated mannitol solution is a potential source of infection. Contamination with paraben-degrading organisms can occur at the time of manufacture. Our findings suggest that contamination of mannitol at a compounding pharmacy occurred. Prompt communication to other hospitals and implementation of infection control measures were effective in avoiding further cases of infection.
Collapse
|
40
|
Chittick P, Russo V, Sims M, Robinson-Dunn B, Oleszkowicz S, Sawarynski K, Powell K, Makin J, Darnell E, Boura JA, Boyanton B, Band J. An outbreak of Pseudomonas aeruginosa respiratory tract infections associated with intrinsically contaminated ultrasound transmission gel. Infect Control Hosp Epidemiol 2013; 34:850-3. [PMID: 23838230 DOI: 10.1086/671268] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We describe an outbreak of Pseudomonas aeruginosa respiratory tract infections related to intrinsically contaminated ultrasound gel used for intraoperative transesophageal echocardiograms in cardiovascular surgery patients. This investigation led to a product safety alert by the Food and Drug Administration and the development of guidelines for appropriate use of ultrasound gel.
Collapse
Affiliation(s)
- Paul Chittick
- Department of Infectious Disease, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
41
|
Loeb S, Vellekoop A, Ahmed HU, Catto J, Emberton M, Nam R, Rosario DJ, Scattoni V, Lotan Y. Systematic review of complications of prostate biopsy. Eur Urol 2013; 64:876-92. [PMID: 23787356 DOI: 10.1016/j.eururo.2013.05.049] [Citation(s) in RCA: 676] [Impact Index Per Article: 61.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2013] [Accepted: 05/24/2013] [Indexed: 12/11/2022]
Abstract
CONTEXT Prostate biopsy is commonly performed for cancer detection and management. The benefits and risks of prostate biopsy are germane to ongoing debates about prostate cancer screening and treatment. OBJECTIVE To perform a systematic review of complications from prostate biopsy. EVIDENCE ACQUISITION A literature search was performed using PubMed and Embase, supplemented with additional references. Articles were reviewed for data on the following complications: hematuria, rectal bleeding, hematospermia, infection, pain, lower urinary tract symptoms (LUTS), urinary retention, erectile dysfunction, and mortality. EVIDENCE SYNTHESIS After biopsy, hematuria and hematospermia are common but typically mild and self-limiting. Severe rectal bleeding is uncommon. Despite antimicrobial prophylaxis, infectious complications are increasing over time and are the most common reason for hospitalization after biopsy. Pain may occur at several stages of prostate biopsy and can be mitigated by anesthetic agents and anxiety-reduction techniques. Up to 25% of men have transient LUTS after biopsy, and <2% have frank urinary retention, with slightly higher rates reported after transperineal template biopsy. Biopsy-related mortality is rare. CONCLUSIONS Preparation for biopsy should include antimicrobial prophylaxis and pain management. Prostate biopsy is frequently associated with minor bleeding and urinary symptoms that usually do not require intervention. Infectious complications can be serious, requiring prompt management and continued work into preventative strategies.
Collapse
Affiliation(s)
- Stacy Loeb
- Department of Urology, New York University, New York, NY, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
42
|
The American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies Joint Committee recommendations for education and training in ultrasound-guided interventional pain procedures. Reg Anesth Pain Med 2013; 37:657-64. [PMID: 23080347 DOI: 10.1097/aap.0b013e318269c189] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
The use of ultrasound in pain medicine for interventional axial, nonaxial, and musculoskeletal pain procedures is rapidly evolving and growing. Because of the lack of specialty-specific guidelines for ultrasonography in pain medicine, an international collaborative effort consisting of members of the Special Interest Group on Ultrasonography in Pain Medicine from the American Society of Regional Anesthesia and Pain Medicine, the European Society of Regional Anaesthesia and Pain Therapy, and the Asian Australasian Federation of Pain Societies developed the following recommendations for education and training in ultrasound-guided interventional pain procedures. The purpose of these recommendations is to define the required skills for performing ultrasound-guided pain procedures, the processes for appropriate education, and training and quality improvement. Training algorithms are outlined for practice- and fellowship-based pathways. The previously published American Society of Regional Anesthesia and Pain Medicine and European Society of Regional Anaesthesia and Pain Therapy education and teaching recommendations for ultrasound-guided regional anesthesia served as a foundation for the pain medicine recommendations. Although the decision to grant ultrasound privileges occurs at the institutional level, the committee recommends that the training guidelines outlined in this document serve as the foundation for educational training and the advancement of the practice of ultrasonography in pain medicine.
Collapse
|
43
|
Leroy S. Infectious risk of endovaginal and transrectal ultrasonography: systematic review and meta-analysis. J Hosp Infect 2013; 83:99-106. [DOI: 10.1016/j.jhin.2012.07.014] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2011] [Accepted: 07/23/2012] [Indexed: 10/27/2022]
|
44
|
Organ M, Grantmyre J, Hutchinson J. Burkholderia cepacia infection of the prostate caused by inoculation of contaminated ultrasound gel during transrectal biopsy of the prostate. Can Urol Assoc J 2013; 4:E58-60. [PMID: 23293687 DOI: 10.5489/cuaj.857] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Burkholderia cepacia infection of the prostate is very rare. We report 6 cases of prostatic infection secondary to inoculation of contaminated ultrasound gel during transrectal biopsy of the prostate. All of these patients required hospitalization and were treated with intravenous antibiotics. One of these cases is the first description of chronic prostatitis with B. cepacia.
Collapse
|
45
|
Oleszkowicz SC, Chittick P, Russo V, Keller P, Sims M, Band J. Infections associated with use of ultrasound transmission gel: proposed guidelines to minimize risk. Infect Control Hosp Epidemiol 2012; 33:1235-7. [PMID: 23143361 DOI: 10.1086/668430] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Susan C Oleszkowicz
- Department of Epidemiology, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | |
Collapse
|
46
|
Pseudomonas aeruginosa Respiratory Tract Infections Associated With Contaminated Ultrasound Gel Used for Transesophageal Echocardiography—Michigan, December 2011–January 2012. Ann Emerg Med 2012; 60:374-6; discussion 376-7. [DOI: 10.1016/j.annemergmed.2012.07.106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
47
|
Bulman JB, Ganezer KS, Halcrow PW, Neeson I. Noncontact ultrasound imaging applied to cortical bone phantoms. Med Phys 2012; 39:3124-33. [PMID: 22755697 DOI: 10.1118/1.4709598] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns. METHODS A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm(3) and in bone mineral density from 0 to 1.7 g/cm(3). RESULTS Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of the in vivo range found in cortical bone. A total of 16-20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%-2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%-2%. Transmittance images of cortical bone phantoms showed differences in the nominal overall BMD values of the phantoms that were large enough to be distinguished by a visual examination. A list of possible sources of errors in quantitative NCU was also included in this study. CONCLUSIONS The results of this paper suggest that NCU might find additional applications in medical imaging, beyond its original and only previous usage in assessing third degree burns. The fact that the authors' phantom measurements using conventional, gel coupled ultrasound are in agreement with those obtained with NCU demonstrates that in spite of large additional levels of attenuation of up to 150 dB and new error sources, NCU could have comparable levels of accuracy to those of conventional quantitative ultrasound, while providing the medical and patient comfort-related advantages of not involving direct contact.
Collapse
Affiliation(s)
- J B Bulman
- Department of Physics, Loyola Marymount University, Los Angeles, CA 90045, USA
| | | | | | | |
Collapse
|
48
|
Gray RA, Williams PL, Dubbins PA, Jenks PJ. Decontamination of transvaginal ultrasound probes: review of national practice and need for national guidelines. Clin Radiol 2012; 67:1069-77. [PMID: 22591688 DOI: 10.1016/j.crad.2012.02.015] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2011] [Revised: 02/05/2012] [Accepted: 02/13/2012] [Indexed: 12/01/2022]
Abstract
AIM To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. MATERIALS AND METHODS A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. RESULTS There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. CONCLUSION While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.
Collapse
Affiliation(s)
- R A Gray
- Derriford Hospital, Crownhill, Plymouth, Devon, UK.
| | | | | | | |
Collapse
|
49
|
Amin A, Dare M, Sangamwar A, Bansal AK. Interaction of antimicrobial preservatives with blow-fill-seal packs: correlating sorption with solubility parameters. Pharm Dev Technol 2011; 17:614-24. [DOI: 10.3109/10837450.2011.557733] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
50
|
Ultrasound echocardiographic gel contamination by Burkholderia cepacia in an Italian hospital. J Hosp Infect 2011; 76:360-1. [PMID: 20970887 DOI: 10.1016/j.jhin.2010.07.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Accepted: 07/29/2010] [Indexed: 10/18/2022]
|