1
|
Ghafur A, Balaguru P, Ramanan SG, Rajendranath R, Raj R, Zehran M, Raja T, Easow JM, Srinivasan S, Devaprasad D, Sukumar T, Nilgar P, Sakthivel K, Nirumal RM, Chandra K, Lakshmi SV, Sethuraman N, Devi Bakthavatchalam Y, Veeraraghavan B. Diving deep for the needle in the haystack: An outbreak investigation of Burkholderia cenocepacia bacteremia. Infect Control Hosp Epidemiol 2024; 45:677-680. [PMID: 38173359 DOI: 10.1017/ice.2023.241] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2024]
Abstract
In an Indian oncology setting, between August and December 2021, 56 patients, developed Burkholderia cenocepacia bacteremia. An investigation revealed a contaminated batch of the antiemetic drug palonosetron. The outbreak was terminated by withdrawing the culprit batch and the findings were reported promptly to regulatory authorities.
Collapse
Affiliation(s)
- Abdul Ghafur
- Infectious Diseases, Apollo Cancer Institute, Teynampet, Chennai
| | - Praveen Balaguru
- Infectious Diseases, Apollo Cancer Institute, Teynampet, Chennai
| | - S G Ramanan
- Medical Oncology, Apollo Cancer Institute, Teynampet, Chennai
| | | | - Revathi Raj
- Pediatric Hemato-Oncology, Apollo Cancer Institute, Teynampet, Chennai
| | - Mohammed Zehran
- Medical Oncology, Apollo Cancer Institute, Teynampet, Chennai
| | - T Raja
- Medical Oncology, Apollo Cancer Institute, Teynampet, Chennai
| | - Jose M Easow
- Medical Oncology, Apollo Cancer Institute, Teynampet, Chennai
| | | | | | | | | | - K Sakthivel
- Pharmacy, Apollo Cancer Institute, Teynampet, Chennai
| | | | - K Chandra
- Infection Control, Apollo Cancer Institute, Teynampet, Chennai
| | - Sree V Lakshmi
- Microbiology, Apollo Cancer Institute, Teynampet, Chennai
| | | | | | | |
Collapse
|
2
|
Kumar SP, Uthra KT, Chitra V, Damodharan N, Pazhani GP. Challenges and mitigation strategies associated with Burkholderia cepacia complex contamination in pharmaceutical manufacturing. Arch Microbiol 2024; 206:159. [PMID: 38483625 DOI: 10.1007/s00203-024-03921-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2023] [Revised: 02/15/2024] [Accepted: 03/02/2024] [Indexed: 03/19/2024]
Abstract
Burkholderia cepacia complex (BCC) is a Gram-negative, non-spore-forming bacterium with more than 20 opportunistic pathogenic species, most commonly found in soil and water. Due to their rapid mutation rates, these organisms are adaptable and possess high genomic plasticity. BCC can cause life-threatening infections in immunocompromised individuals, such as those with cystic fibrosis, chronic granulomatous disease, and neonates. BCC contamination is a significant concern in pharmaceutical manufacturing, frequently causing non-sterile product recalls. BCC has been found in purified water, cosmetics, household items, and even ultrasound gel used in veterinary practices. Pharmaceuticals, personal care products, and cleaning solutions have been implicated in numerous outbreaks worldwide, highlighting the risks associated with intrinsic manufacturing site contamination. Regulatory compliance, product safety, and human health protection depend on testing for BCC in pharmaceutical manufacturing. Identification challenges exist, with BCC often misidentified as other bacteria like non-lactose fermenting Escherichia coli or Pseudomonas spp., particularly in developing countries where reporting BCC in pharmaceuticals remains limited. This review comprehensively aims to address the organisms causing BCC contamination, genetic diversity, identification challenges, regulatory requirements, and mitigation strategies. Recommendations are proposed to aid pharmaceutical chemists in managing BCC-associated risks and implementing prevention strategies within manufacturing processes.
Collapse
Affiliation(s)
- Sethuraman Prem Kumar
- Department of Pharmaceutical Quality Assurance, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603203, India
| | - Karupanagounder Thangaraj Uthra
- Department of Pharmaceutical Chemistry, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603 203, India
| | - Vellapandian Chitra
- Department of Pharmacology, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603203, India
| | - Narayanasamy Damodharan
- Department of Pharmaceutics, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603203, India
| | - Gururaja Perumal Pazhani
- Department of Pharmaceutical Chemistry, SRM College of Pharmacy, SRM Institute of Science and Technology, Kattankulathur, Tamil Nadu, 603 203, India.
| |
Collapse
|
3
|
Karthikeyan R, Agri H, Yadav A, Jayakumar V, Kiranmayee B, Karikalan M, Chandra M, Lyngdoh V, Ghatak S, Sinha DK, Singh BR. A study on the occurrence of Burkholderia cepacia complex in ultrasound gels used in different veterinary clinical settings in India. Vet Res Commun 2023; 47:1413-1425. [PMID: 36914918 DOI: 10.1007/s11259-023-10091-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 02/26/2023] [Indexed: 03/14/2023]
Abstract
Burkholderia cepacia complex (Bcc) organisms are emerging multidrug-resistant pathogens. They are opportunistic and cause severe diseases in humans that may result in fatal outcomes. They are mainly reported as nosocomial pathogens, and transmission often occurs through contaminated pharmaceutical products. From 1993 to 2019, 14 Bcc outbreaks caused by contaminated ultrasound gels (USGs) have been reported in several countries, including India. We screened a total of 63 samples of USGs from various veterinary and human clinical care centers across 17 states of India and isolated 32 Bcc strains of Burkholderia cenocepacia (46.8%), B. cepacia (31.3%), B. pseudomultivorans (18.8%) and B. contaminans (3.1%) species. Some isolates were co-existent in a single ultrasound gel sample. The isolation from unopened gel bottles revealed the intrinsic contamination from manufacturing sites. The MALDI-TOF analysis to identify the Bcc at the species level was supported by the partial sequencing of the recA gene for accurate species identification. The phylogenetic analysis revealed that isolates shared clades with human clinical isolates, which is an important situation because of the possible infections of Bcc by USGs both in humans and animals. The pulsed field gel electrophoresis (PFGE) typing identified the genetic variation among the Bcc isolates present in the USGs. The findings indicated USGs as the potential source of Bcc species.
Collapse
Affiliation(s)
- Ravichandran Karthikeyan
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Himani Agri
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Akanksha Yadav
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Varsha Jayakumar
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Bhimavarapu Kiranmayee
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Mathesh Karikalan
- Center for wildlife Conservation Management and Disease Surveillance, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Mudit Chandra
- Department of Veterinary Microbiology, College of Veterinary Science, Guru Angad Dev Veterinary and Animal Sciences University, Ludhiana, Punjab, India
| | - Vanita Lyngdoh
- Division of Animal and Fisheries Sciences, ICAR Research Complex for NEH Region, Umiam, Meghalaya, India
| | - Sandeep Ghatak
- Division of Animal and Fisheries Sciences, ICAR Research Complex for NEH Region, Umiam, Meghalaya, India
| | - Dharmendra K Sinha
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India
| | - Bhoj R Singh
- Division of Epidemiology, ICAR-Indian Veterinary Research Institute, Izatnagar, Uttar Pradesh, India.
| |
Collapse
|
4
|
Angrup A, Kanaujia R, Biswal M, Ray P. Systematic review of ultrasound gel associated Burkholderia cepacia complex outbreaks: Clinical presentation, sources and control of outbreak. Am J Infect Control 2022; 50:1253-1257. [PMID: 35158013 DOI: 10.1016/j.ajic.2022.02.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Revised: 01/30/2022] [Accepted: 02/01/2022] [Indexed: 11/01/2022]
Abstract
BACKGROUND Burkholderia cepacia complex (Bcc) is an emerging opportunistic pathogen among immunocompromised patients. It frequently contaminates saline, fluids and ultrasound (US) gel used in hospitals. This systematic review was conducted to analyze Bcc outbreaks due to ultrasound (US) gel for better management of these outbreaks. METHODS As per PRISMA guidelines, electronic databases "Embase" and "Pubmed" and "Web of sciences" were searched from 1991 to April, 2021 to identify studies causing Burkholderia spp outbreak due to contamination of US gels. RESULTS The search identified 14 outbreak reports that met our inclusion criteria. Bacteremia was the most common clinical presentation in ten studies followed by urinary tract infections in 4 studies. In most of the studies B. cepacia was the most common isolated organism. Other members like B. ambifaria, B. contaminans, and B. stabilis caused outbreaks in two studies. Pulsed field gel electrophoresis and multilocus sequence typing were commonly employed methods to study the clonal association. In 8 outbreaks, intrinsic contamination of the gel, that is, contamination from manufacturing site, was present and 4 studies, extrinsic contamination, that is, contamination from environment was responsible for outbreak. CONCLUSION This review highlights the importance of US gel as a source of outbreak in health-care facilities. Ensuring sterility of US gel, sound epidemiological investigation of outbreak and prompt response by infection control team can prevent these outbreaks.
Collapse
Affiliation(s)
- Archana Angrup
- Department of Medical Microbiology, PGIMER, Chandigarh, India
| | | | - Manisha Biswal
- Department of Medical Microbiology, PGIMER, Chandigarh, India.
| | - Pallab Ray
- Department of Medical Microbiology, PGIMER, Chandigarh, India
| |
Collapse
|
5
|
Kwayess R, Al Hariri HE, Hindy JR, Youssef N, Haddad SF, Kanj SS. Burkholderia cepacia Infections at Sites Other than the Respiratory Tract: A Large Case Series from a Tertiary Referral Hospital in Lebanon. J Epidemiol Glob Health 2022; 12:274-280. [PMID: 35773618 PMCID: PMC9470806 DOI: 10.1007/s44197-022-00048-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 06/09/2022] [Indexed: 11/09/2022] Open
Abstract
Objectives The Burkholderia cepacia complex (Bcc), which was originally thought to be a single species, represents a group of 24 distinct species that are often resistant to multiple antibiotics, and usually known to cause life-threatening pulmonary infections in cystic fibrosis patients. Herein we describe a series of non-respiratory Bcc infections, the risk factors and epidemiologic factors, in addition to the clinical course. Patients and methods This is a retrospective chart review of 44 patients with documented B. cepacia infections isolated from sites other than the respiratory tract admitted between June 2005 and February 2020 to the American University of Beirut Medical Center (AUBMC), a tertiary referral hospital for Lebanon and the Middle East region. The epidemiological background of these patients, their underlying risk factors, the used antibiotic regimens, and the sensitivities of the B. cepacia specimens were collected. Results The majority of the Bcc infections (26/44, 59.1%) were hospital-acquired infections. The most common nationality of the patients was Iraqi (18/44, 40.9%), and the most common site of infection was bacteremia (17/44, 38.6%), followed by skin and soft tissues infections (16/44, 36.4%) and vertebral osteomyelitis (8/44, 18.2%). Most of the isolated B. cepacia were susceptible to ceftazidime, carbapenems, followed by TMP-SMX. Patients responded well to therapy with good overall outcome. Conclusions Bcc can cause infections outside the respiratory tract, mostly as hospital-acquired infections and in immunocompromised patients. Most patients were referred from countries inflicted by wars raising the possibility of a potential role of conflicts which need to be investigated in future studies. Directed therapy according to susceptibility results proved effective in most patients.
Collapse
Affiliation(s)
- Rola Kwayess
- Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon
| | - Housam Eddine Al Hariri
- Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon
| | - Joya-Rita Hindy
- Division of Infectious Diseases, American University of Beirut Medical Center, Riad El Solh, PO Box 11-0236, Beirut, 1107 2020, Lebanon
| | - Nada Youssef
- Department of Internal Medicine, American University of Beirut Medical Center, Beirut, Lebanon
| | - Sara F Haddad
- Division of Infectious Diseases, American University of Beirut Medical Center, Riad El Solh, PO Box 11-0236, Beirut, 1107 2020, Lebanon
| | - Souha S Kanj
- Division of Infectious Diseases, American University of Beirut Medical Center, Riad El Solh, PO Box 11-0236, Beirut, 1107 2020, Lebanon.
| |
Collapse
|
6
|
Outbreak of B.cepacia bacteremia following use of contaminated drug vials in a tertiary care centre. Indian J Med Microbiol 2021; 40:119-121. [PMID: 34969551 DOI: 10.1016/j.ijmmb.2021.12.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2021] [Revised: 12/02/2021] [Accepted: 12/08/2021] [Indexed: 11/21/2022]
Abstract
PURPOSE We report an outbreak of Burkholderia cepacia bacteremia related to contaminated drug vials. MATERIALS AND METHODS All patients having fever post coronary angiography were analysed from February 12, 2019 to March 18, 2019. A thorough inspection of the cath lab was done by the infection control team. Surveillance cultures were taken from various places including swabs from the all the drug vials used for the patients. RESULTS During the above period, a total of 898 cases had been taken up for angiographic procedures in all the four cath labs, out of which 72 were for neurological issues. Among these patients only 60 patients reported fever. No fever was reported among those who underwent angiograms for neurological issues. Of the 60 patients who had fever, 38 patients satisfied the case definition. Blood cultures were sent for 7(18.4%) patients and 17(44.7%) had been started on antibiotics. After identification of 2 cases with the positive culture and following the news that a drug manufacturing company had recalled a particular batch of drug (diltiazem), the source of the outbreak was thought to be contaminated diltiazem vials. Retrospectively it was noted that the 38 patients had received the diltiazem from three different batches. Subsequently the same organism was isolated from the drug vials also. Both the isolates were phenotypically the same. There were no patients with fever post procedure reported the week after the batch of diltiazem was recalled. CONCLUSION The outbreak was thus linked to the contaminated diltiazem vials. Physicians should thus be aware of such outbreaks that can cause bacteremias.
Collapse
|
7
|
Deb AK, Chavan P, Kaliaperumal S, Sistla S, Madigubba H, Sarkar S, Neena A. Clinical profile, visual outcome and root cause analysis of post-operative cluster endophthalmitis due to Burkholderia cepacia complex. Indian J Ophthalmol 2021; 70:164-170. [PMID: 34937230 PMCID: PMC8917597 DOI: 10.4103/ijo.ijo_1035_21] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Purpose: To present varied clinical presentations, surveillance reports, and final visual outcomes of a rare outbreak of cluster endophthalmitis caused by gram-negative, opportunistic bacilli, Burkholderia cepacia complex (Bcc). Methods: Details of five patients who developed postoperative cluster endophthalmitis were collected. For each patient, an undiluted vitreous sample was collected during vitreous tap. Bacterial culture from the vitreous sample in each case had grown Bcc. Surveillance investigations for root cause analysis (RCA) were performed in the operating room (OR), admission, and day-care wards to localize the source. Results: Four patients had undergone phacoemulsification surgery, and one patient had undergone penetrating keratoplasty. Each patient received an initial dose of empiric intravitreal ceftazidime and vancomycin. The organism isolated in each case was sensitive to ceftazidime, cotrimoxazole, and meropenem and resistant to other antibiotics. Core vitrectomy was done after 48–60 hours in four patients along with intravitreal imipenem injection. One patient did not provide consent for core vitrectomy and subsequently developed phthisis bulbi. Three patients had subsequent recurrences. Two patients had a final BCVA of 20/60, two had BCVA better than 20/200, while one patient had no perception of light. None of the surveillance samples from the OR complex could isolate Burkholderia. Conclusion: Extensive OR surveillance should be done to identify the potential source of infection. However, the source may not be identifiable in few instances like in our case. Longer follow-up is recommended in cases of Bcc endophthalmitis due to the persistent nature of the infection.
Collapse
Affiliation(s)
- Amit Kumar Deb
- Department of Ophthalmology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Pratima Chavan
- Department of Ophthalmology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Subashini Kaliaperumal
- Department of Ophthalmology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Sujatha Sistla
- Department of Microbiology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Haritha Madigubba
- Department of Microbiology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Sandip Sarkar
- Department of Ophthalmology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| | - Aswathi Neena
- Department of Ophthalmology, Jawaharlal Institute Postgraduate Medical Education and Research, Puducherry, India
| |
Collapse
|
8
|
Bilgin H, Altınkanat Gelmez G, Bayrakdar F, Sayın E, Gül F, Pazar N, Çulha G, Süzük Yıldız S, Cinel I, Korten V. An outbreak investigation of Burkholderia cepacia infections related with contaminated chlorhexidine mouthwash solution in a tertiary care center in Turkey. Antimicrob Resist Infect Control 2021; 10:143. [PMID: 34629114 PMCID: PMC8502507 DOI: 10.1186/s13756-021-01004-8] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 09/01/2021] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND We report a nosocomial outbreak caused by Burkholderia cepacia that occurred among six patients admitted in the medical and surgical intensive care unit between 04 March 2019 and 02 April 2019 in Istanbul, Turkey. METHODS The outbreak investigation was launched on 11 March 2019 five days after the detection of B. cepacia in four different patients. We defined potential reservoirs and started environmental screening. We sampled the liquid solutions used in patient care activities. Pulse-field gel electrophoresis (PFGE) was performed to determine the genetic relatedness of environmental and patient samples. RESULTS Burkholderia cepacia was isolated in tracheal aspiration cultures of six patients. Three out of six patients developed healthcare-associated pneumoniae due to B. cepacia. Environmental cultures in the ICUs revealed B. cepacia growth in 2% chlorhexidine-gluconate mouthwash solution that been used in the colonized patients as well as in samples obtained from the unused products. PFGE revealed the patient and a specific batch of chlorhexidine mouthwash solution samples had a 96% similarity. CONCLUSION Contamination of medical solutions used in critical patient care could cause outbreaks and should be detected early by infection control teams.
Collapse
Affiliation(s)
- Hüseyin Bilgin
- Infectious Diseases, and Clinical Microbiology, Marmara University Hospital, Istanbul, Turkey. .,Marmara University Hospital, Fevzi Cakmak Mah, Muhsinyazicioglu Cad No: 10 Pendik, Istanbul, Turkey.
| | | | - Fatma Bayrakdar
- National Molecular Microbiology Reference Laboratory, Public Health General Directorate, Ankara, Turkey
| | - Elvan Sayın
- Medical Microbiology, Marmara University Hospital, Istanbul, Turkey
| | - Fethi Gül
- Anesthesiology & Reanimation, and Critical Care, Marmara University Hospital, Istanbul, Turkey
| | - Nazlı Pazar
- Infection Prevention and Control, Marmara University Hospital, Istanbul, Turkey
| | - Gülcan Çulha
- Infection Prevention and Control, Marmara University Hospital, Istanbul, Turkey
| | - Serap Süzük Yıldız
- National Molecular Microbiology Reference Laboratory, Public Health General Directorate, Ankara, Turkey
| | - Ismail Cinel
- Anesthesiology & Reanimation, and Critical Care, Marmara University Hospital, Istanbul, Turkey
| | - Volkan Korten
- Infectious Diseases, and Clinical Microbiology, Marmara University Hospital, Istanbul, Turkey
| |
Collapse
|
9
|
Global burden, point sources, and outbreak management of healthcare-associated Burkholderia cepacia infections: An integrative review. Infect Control Hosp Epidemiol 2021; 41:777-783. [PMID: 32441235 DOI: 10.1017/ice.2020.184] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
OBJECTIVE To examine the global burden, associated point sources, and successful prevention and control measures for documented outbreaks of Burkholderia cepacia healthcare-associated infections (HAIs). DESIGN Integrative review. METHODS A review of all outbreaks of Burkholderia cepacia HAIs published in the peer-reviewed literature between January 1970 and October 2019 was conducted to identify the global burden, associated point sources, and successful prevention and control measures using the Guidelines for Outbreak Reports and Intervention Studies of Nosocomial Infections (ORION). RESULTS In total, we reviewed 125 documented outbreaks of Burkholderia cepacia-related HAIs worldwide. The reported B. cepacia HAIs for this period involved 3,287 patients. The point sources were identified in most outbreaks of B. cepacia HAIs (n = 93; 74.4%); they included medication vials, disinfectants, and antiseptics. Moreover, 95 of the outbreak reports (76%) described effective prevention and control measures, but only 33 reports indicated the use of a combination of environment-, patient- and staff-related measures. None of the outbreak reports used the ORION guidelines. CONCLUSIONS Outbreaks of Burkholderia cepacia HAIs are an ongoing challenge. They are often associated with immunocompromised patients who acquire the infection from exposure to contaminated medications, products, and equipment. These outbreaks are not infrequent, and a range of infection prevention and control measures have been effective in arresting spread. The use of ORION guidelines for outbreak reporting would improve the quality of information and data to generate evidence for translation into practice.
Collapse
|
10
|
Mullins K, Burnham K, Henricson EK, Cohen S, Fair J, Ray JW. Identification and Analysis of Bacterial Contamination of Ultrasound Transducers and Multiuse Ultrasound Transmission Gel Bottle Tips Before and After the Aseptic Cleansing Technique. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2020; 39:1957-1963. [PMID: 32339352 DOI: 10.1002/jum.15300] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/14/2020] [Accepted: 03/22/2020] [Indexed: 06/11/2023]
Abstract
OBJECTIVES To provide a descriptive analysis for species identification of culture and Gram stain results from ultrasound transducers and multiuse ultrasound transmission gel bottle tips in active clinical use and to compare bacterial cultures from ultrasound transducers before and after aseptic cleansing. METHODS A prospective blinded descriptive analytic study of 18 distinct clinical care sites within a single primary clinical institution was conducted. Before and after a disinfectant towel cleanse, transducers were pressed against tryptic soy agar contact plates. Plates were deidentified and submitted for blind incubation, Gram staining, and species identification with microsequencing. Results were classified as clinically relevant (CR) or non-clinically relevant. In total, 188 samples were analyzed: 80 from ultrasound transducers before and cleansing, 13 from multiuse gel bottle tips before and after cleansing, and 2 precleansing samples from the data collector's pen and badge. RESULTS Fifty-nine precleansing samples (73.8%) grew cultures with CR bacteria, and 21 samples (26.3%) did not. Staphylococcus simulans represented 31.0% of all positive culture samples. Thirteen postcleansing samples (16.3%) grew cultures with CR bacteria, equating to a 78.0% reduction of CR bacterial growth (likelihood ratio, 57.10; P < .001). CONCLUSIONS Ultrasound transducers have a notable CR bacterial burden and may serve as potential infective vectors. Aseptic cleansing effectively eliminates most of the bacterial load from ultrasound transducers, but some bacteria persist, presenting a risk of nosocomial infection with ultrasound-guided interventions. These findings support American Institute of Ultrasound in Medicine 2018 guidelines intended to ensure an appropriate level of transducer preparation based on the examination type while emphasizing rational infection control measures to minimize the risk of potential patient harm.
Collapse
Affiliation(s)
- Kevin Mullins
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Kevin Burnham
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Erik K Henricson
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - Stuart Cohen
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| | - James Fair
- Department of Surgery, Division of Emergency Medicine, University of Utah, Salt Lake City, Utah, USA
| | - Jeremiah W Ray
- Department of Physical Medicine and Rehabilitation, University of California, Davis, California, USA
| |
Collapse
|
11
|
Okomo U, Senghore M, Darboe S, Bojang E, Zaman SMA, Hossain MJ, Nwakanma D, Le Doare K, Holt KE, Hos NJ, Lawn JE, Bentley SD, Kampmann B. Investigation of sequential outbreaks of Burkholderia cepacia and multidrug-resistant extended spectrum β-lactamase producing Klebsiella species in a West African tertiary hospital neonatal unit: a retrospective genomic analysis. LANCET MICROBE 2020; 1:e119-e129. [DOI: 10.1016/s2666-5247(20)30061-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/12/2020] [Accepted: 05/13/2020] [Indexed: 10/23/2022]
|
12
|
Becker SL, Berger FK, Feldner SK, Karliova I, Haber M, Mellmann A, Schäfers HJ, Gärtner B. Outbreak of Burkholderia cepacia complex infections associated with contaminated octenidine mouthwash solution, Germany, August to September 2018. ACTA ACUST UNITED AC 2019; 23. [PMID: 30352639 PMCID: PMC6199865 DOI: 10.2807/1560-7917.es.2018.23.42.1800540] [Citation(s) in RCA: 25] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Three German patients developed nosocomial pneumonia after cardiac surgery and had Burkholderia cepacia complex detected in respiratory specimens. Two patients died of septic multi-organ failure. Whole-genome sequencing detected genetically identical B. cepacia complex strains in patient samples, from a batch of octenidine mouthwash solution, which had been used for nursing care, as well as in samples obtained from the manufacturer during production. Contamination of medical products during manufacturing may lead to international outbreaks.
Collapse
Affiliation(s)
- Sören L Becker
- Institute of Medical Microbiology and Hygiene, Saarland University, Homburg/Saar, Germany
| | - Fabian K Berger
- Institute of Medical Microbiology and Hygiene, Saarland University, Homburg/Saar, Germany
| | - Susanne K Feldner
- Department of Thoracic and Cardiovascular Surgery, Saarland University, Homburg/Saar, Germany
| | - Irem Karliova
- Department of Thoracic and Cardiovascular Surgery, Saarland University, Homburg/Saar, Germany
| | - Manfred Haber
- Hospital Pharmacy, Saarland University, Homburg/Saar, Germany
| | | | - Hans-Joachim Schäfers
- Department of Thoracic and Cardiovascular Surgery, Saarland University, Homburg/Saar, Germany
| | - Barbara Gärtner
- Institute of Medical Microbiology and Hygiene, Saarland University, Homburg/Saar, Germany
| |
Collapse
|
13
|
Yagnik KJ, Kalyatanda G, Cannella AP, Archibald LK. Outbreak of Acinetobacter baumannii associated with extrinsic contamination of ultrasound gel in a tertiary centre burn unit. Infect Prev Pract 2019; 1:100009. [PMID: 34368675 PMCID: PMC8336045 DOI: 10.1016/j.infpip.2019.100009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Accepted: 06/20/2019] [Indexed: 11/28/2022] Open
Abstract
Background During 2011 and 2012, an increase in occurrence of multidrug-resistant Acinetobacter baumannii infections was recorded in the Shands Hospital Burn Intensive Care Unit (BICU). An epidemic curve together with strain typing was consistent with an intermittent common source outbreak. An investigation was therefore initiated. Aim To identify risk factors for A. baumannii infection, characterize the source of the pathogen, implement control measures to terminate the outbreak, and institute preventive measures. Methods We conducted a retrospective case-control study; reviewed BICU infection control policies, practices and procedures, and patient exposure to healthcare workers (HCWs), and obtained epidemiologically-directed environmental cultures. Findings Eleven patients met the case definition. On multivariate analysis, case-patients were more likely to have undergone an ultrasound procedure in the BICU (adjusted odds ratio [AOR]: 19.5; confidence interval [CI]: 2.4-435) or have a FlexiSeal™ device (AOR: 11.9, CI:1.3-276). Epidemiologically-directed cultures of the environment, ultrasound equipment, and ultrasound gel from opened containers on the ultrasound trolley and in the Ultrasound Department were negative for the outbreak pathogen. Culture of an open ultrasound gel dispenser stored in the Ultrasound Department yielded an A. baumannii strain with DNA banding patterns identical to the outbreak strain. Conclusions Based on data from our epidemiologic, microbiologic, and observational studies, we believe that inadvertent extrinsic contamination of the gel dispenser occurred in the Ultrasound Department. Contaminated gel was then dispensed into multiuse vials of gel stored on the mobile carts. The outbreak was stemmed by instituting changes in practices in the Ultrasound Department, including introduction of single-use ultrasound vials and storage of ultrasound gel.
Collapse
Affiliation(s)
- Kruti J Yagnik
- University of Florida College of Medicine, Department of Medicine, Gainesville, FL, USA
| | - Gautam Kalyatanda
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA
| | - Anthony P Cannella
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA.,University of Florida College of Medicine, Department of Molecular Genetics & Microbiology, Gainesville, FL, USA.,University of Florida College of Medicine, Emerging Pathogens Institute, Gainesville, FL, USA
| | - Lennox K Archibald
- University of Florida College of Medicine, Department of Medicine, Division of Infectious Diseases & Global Medicine, Gainesville, FL, USA.,Malcolm Randall Veterans Health Administration Medical Centre, Gainesville, FL, USA
| |
Collapse
|
14
|
Incidence of residual bacterial contamination of transvaginal ultrasound probes. J Med Ultrason (2001) 2019; 46:475-479. [DOI: 10.1007/s10396-019-00941-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2019] [Accepted: 03/08/2019] [Indexed: 10/27/2022]
|
15
|
Solaimalai D, Devanga Ragupathi NK, Ranjini K, Paul H, Verghese VP, Michael JS, Veeraraghavan B, James EJ. Ultrasound gel as a source of hospital outbreaks: Indian experience and literature review. Indian J Med Microbiol 2019; 37:263-267. [PMID: 31745029 DOI: 10.4103/ijmm.ijmm_19_249] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Abstract
Purpose Hospital outbreaks are observed increasingly worldwide with various organisms from different sources such as contaminated ultrasound gel, intravenous (IV) fluids and IV medications. Among these, ultrasound gel is one of the most commonly reported sources for Burkholderia cepacia complex (Bcc) outbreaks. In this study, we describe our experience on investigation and the management of Bcc bacteraemia outbreak due to contaminated ultrasound gel from a tertiary care centre, South India. Materials and Methods Over a 10-day period in October 2016, seven children in our Paediatric intensive care unit (ICU) were found to have bacteraemia with Bcc isolated from their blood culture. Repeated isolation of the same organism with similar antimicrobial susceptibility pattern over a short incubation period from the same location, confirmed the outbreak. An active outbreak investigation, including environmental surveillance, was carried out to find the source and control the outbreak. Isolates were subjected to multi-locus sequence typing (MLST) and global eBURST (goeBURST) analysis. Results Environmental surveillance revealed contaminated ultrasound gel as the source of infection. MLST and goeBURST analysis confirmed that the outbreak was caused by a novel sequence type 1362 with the same clonal complex CC517. The outbreak was controlled by stringent infection control measures, withdrawal of contaminated ultrasound gel from regular usage and implementing the practice of using ultrasonogram (USG) probe cover for USG screening and guided procedures. Conclusion This report highlights the importance of early identification of an outbreak, prompt response of the ICU and infection control teams, sound environmental and epidemiological surveillance methods to identify the source and stringent infection control measures to control the outbreak. Contaminated ultrasound gel can be a potential source for healthcare-associated infection, which cannot be overlooked.
Collapse
Affiliation(s)
| | | | - Kala Ranjini
- Department of Child Health, Christian Medical College, Vellore, Tamil Nadu, India
| | - Hema Paul
- Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Valsan P Verghese
- Department of Child Health; Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Joy Sarojini Michael
- Department of Clinical Microbiology; Hospital Infection Control Committee, Christian Medical College, Vellore, Tamil Nadu, India
| | - Balaji Veeraraghavan
- Department of Clinical Microbiology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Ebor Jacob James
- Department of Child Health, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
16
|
Westerway SC, Basseal JM, Abramowicz JS. Medical Ultrasound Disinfection and Hygiene Practices: WFUMB Global Survey Results. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:344-352. [PMID: 30409470 DOI: 10.1016/j.ultrasmedbio.2018.09.019] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 09/19/2018] [Accepted: 09/19/2018] [Indexed: 06/08/2023]
Abstract
As ultrasound technology rapidly evolves and is used more frequently in every area of medical diagnosis and treatment, it may be overlooked as a potential vector in the transmission of a health care-associated infection. A survey on disinfection and hygiene practice in medical ultrasound was disseminated via the World Federation for Ultrasound in Medicine and Biology (WFUMB) to its six member federations and associated ultrasound societies globally. One thousand twenty-nine responses were obtained across a broad range of ultrasound practitioners. A total of 76% of respondents used transducer covers every time to scan open wounds and 71% when blood and bodily fluids were present or for an interventional procedure. Approved high-level disinfectants are not always used, even when blood comes into contact with the transducer or after endocavity scans. Alcohol-based wipes were used by many respondents to clean both external transducers and endocavity transducers. Open-ended responses indicated that a large caseload hindered the time required for cleaning and that access to clear guidelines would be beneficial. Global survey results indicate that some users do not comply with disinfection practice, and there is a gap in knowledge on basic infection prevention and control education within the ultrasound unit. As the infectious status of a patient is not often disclosed prior to an ultrasound examination, training in suitable protocols for the cleaning and disinfection of ultrasound equipment is imperative to mitigate the risk of potential infection.
Collapse
Affiliation(s)
- Susan Campbell Westerway
- Department of Dentistry and Health Sciences, Charles Sturt University, New South Wales, Australia; World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA
| | - Jocelyne M Basseal
- Australasian Society for Ultrasound in Medicine, Chatswood, New South Wales, Australia.
| | - Jacques S Abramowicz
- World Federation for Ultrasound in Medicine and Biology (WFUMB), Chicago, Illinois, USA; Department of Obstetrics & Gynecology, University of Chicago, Chicago, Illinois, USA
| |
Collapse
|
17
|
Milton SC, Cronin AJ, Monti JD. Evaluation of Glucomannan Powder as an Ultrasound Transmission Gel Alternative for Resource-Constrained Environments: A Prospective, Comparative Study. Wilderness Environ Med 2018; 29:446-452. [PMID: 30290983 DOI: 10.1016/j.wem.2018.06.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Revised: 06/15/2018] [Accepted: 06/15/2018] [Indexed: 11/30/2022]
Abstract
INTRODUCTION Resource and logistical constraints may limit the availability of commercial ultrasound (US) transmission gel (USTG) in austere environments. Glucomannan powder, a dietary fiber supplement, can be mixed with tap water to form a gel that may be a field-expedient substitute for USTG. We compared glucomannan gel with a commercial USTG for US image adequacy and quality. METHODS A single clinician obtained 193 US video clips from 14 different examinations on live-tissue and simulation training models using both commercial and glucomannan USTGs. Four US fellowship-trained providers, blinded to type of gel used, independently reviewed the randomized US video clips. The primary outcome of US image adequacy was scored as "yes" or "no" and analyzed using Pearson χ2 analysis. The secondary outcome of image quality was rated on a 0 to 5 Likert scale and analyzed with the independent t test. RESULTS For US image adequacy, commercial USTG was superior to glucomannan gel (P=0.042, 95% CI: 96.5-96.6%), with commercial USTG adequate in 96.6% of images (375 of 388 "yes"), whereas glucomannan USTG was adequate in 93.5% (359 of 384 "yes") of images. For US image quality there was no statistically significant difference between the 2 USTGs (P=0.176, 95% CI: 93.4-93.5%), with commercial USTG rated at 3.4±1.0 and glucomannan gel at 3.3±1.1. CONCLUSION Despite a high image adequacy rate, glucomannan gel proved inferior to commercial USTG for US image adequacy but produced equivalent image quality. Glucomannan USTG may be a reasonable substitute when commercial USTG is unavailable.
Collapse
Affiliation(s)
- Sandra C Milton
- Department of Emergency Medicine, Madigan Army Medical Center, Tacoma, WA
| | - Aaron J Cronin
- Department of Emergency Medicine, Madigan Army Medical Center, Tacoma, WA
| | - Jonathan D Monti
- Department of Emergency Medicine, Madigan Army Medical Center, Tacoma, WA.
| |
Collapse
|
18
|
Kanamori H, Rutala WA, Weber DJ. The Role of Patient Care Items as a Fomite in Healthcare-Associated Outbreaks and Infection Prevention. Clin Infect Dis 2018; 65:1412-1419. [PMID: 28520859 DOI: 10.1093/cid/cix462] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2017] [Accepted: 05/11/2017] [Indexed: 01/28/2023] Open
Abstract
Patient-care items can serve as a source or reservoir for healthcare-associated pathogens in hospitals. We reviewed healthcare- associated outbreaks from medical equipment and provide infection prevention recommendations. Multiple healthcare-associated outbreaks via a contaminated patient-care item were identified, including infections with multidrug-resistant organisms. The type of patient care items implicated as a fomite causing healthcare-associated infections (HAIs) has changed over time. Patient populations at risk were most commonly critically ill patients in adult and neonatal intensive care units. Most fomite related healthcare-associated outbreaks were due to inappropriate disinfection practices. Repeated healthcare-associated outbreaks via medical equipment highlight the need for infectious disease professionals to understand that fomites/medical devices may be a source of HAIs. The introduction of new and more complex medical devices will likely increase the risk that such devices serve as a source of HAIs. Assuring appropriate cleaning and disinfection or sterilization of medical equipment is necessary to prevent future fomite-associated outbreaks.
Collapse
Affiliation(s)
- Hajime Kanamori
- Division of Infectious Diseases, University of North Carolina School of Medicine, North Carolina.,Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina
| | - William A Rutala
- Division of Infectious Diseases, University of North Carolina School of Medicine, North Carolina.,Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina
| | - David J Weber
- Division of Infectious Diseases, University of North Carolina School of Medicine, North Carolina.,Hospital Epidemiology, University of North Carolina Health Care, Chapel Hill, North Carolina
| |
Collapse
|
19
|
Nyhsen CM, Humphreys H, Koerner RJ, Grenier N, Brady A, Sidhu P, Nicolau C, Mostbeck G, D’Onofrio M, Gangi A, Claudon M. Infection prevention and control in ultrasound - best practice recommendations from the European Society of Radiology Ultrasound Working Group. Insights Imaging 2017; 8:523-535. [PMID: 29181694 PMCID: PMC5707224 DOI: 10.1007/s13244-017-0580-3] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2017] [Revised: 10/03/2017] [Accepted: 10/05/2017] [Indexed: 12/31/2022] Open
Abstract
OBJECTIVES The objective of these recommendations is to highlight the importance of infection prevention and control in ultrasound (US), including diagnostic and interventional settings. METHODS Review of available publications and discussion within a multidisciplinary group consistent of radiologists and microbiologists, in consultation with European patient and industry representatives. RECOMMENDATIONS Good basic hygiene standards are essential. All US equipment must be approved prior to first use, including hand held devices. Any equipment in direct patient contact must be cleaned and disinfected prior to first use and after every examination. Regular deep cleaning of the entire US machine and environment should be undertaken. Faulty transducers should not be used. As outlined in presented flowcharts, low level disinfection is sufficient for standard US on intact skin. For all other minor and major interventional procedures as well as all endo-cavity US, high level disinfection is mandatory. Dedicated transducer covers must be used when transducers are in contact with mucous membranes or body fluids and sterile gel should be used inside and outside covers. CONCLUSIONS Good standards of basic hygiene and thorough decontamination of all US equipment as well as appropriate use of US gel and transducer covers are essential to keep patients safe. MAIN MESSAGES • Transducers must be cleaned/disinfected before first use and after every examination. • Low level disinfection is sufficient for standard US on intact skin. • High level disinfection is mandatory for endo-cavity US and all interventions. • Dedicated transducer covers must be used for endo-cavity US and all interventions. • Sterile gel should be used for all endo-cavity US and all interventions.
Collapse
Affiliation(s)
- Christiane M. Nyhsen
- Radiology Department, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Hilary Humphreys
- Department of Clinical Microbiology, The Royal College of Surgeons in Ireland, Dublin, Ireland
- Department of Microbiology, Beaumont Hospital, Dublin, Ireland
| | - Roland J. Koerner
- Infection Prevention and Control Department, Department of Microbiology, City Hospitals Sunderland, Kayll Road, Sunderland, SR4 7TP UK
| | - Nicolas Grenier
- Service d’Imagerie Diagnostique et Interventionnelle de l’Adulte Groupe Hospitalier, Pellegrin Place Amelie Raba-Leon, 33076 Bordeaux, Cedex France
| | - Adrian Brady
- Department of Radiology, Mercy University Hospital, Grenville Place, Cork, T12 WE28 Ireland
| | - Paul Sidhu
- King’s College Hospital, Denmark Hill, London, SE5 9RS UK
| | | | | | - Mirko D’Onofrio
- Radiology, Policlinico G.B. Rossi, VERONA, piazzale LA SCURO 10, 37134 Verona, Italy
| | - Afshin Gangi
- NHC, 1, Place de l’Hôpital, 67091 Strasbourg, France
| | - Michel Claudon
- Children Hospital, University Hospital - Nancy Brabois, Rue du Morvan, 54511 Vandoeuvre Les Nancy, Cedex France
| |
Collapse
|
20
|
Kenna DTD, Lilley D, Coward A, Martin K, Perry C, Pike R, Hill R, Turton JF. Prevalence of Burkholderia species, including members of Burkholderia cepacia complex, among UK cystic and non-cystic fibrosis patients. J Med Microbiol 2017; 66:490-501. [PMID: 28463663 DOI: 10.1099/jmm.0.000458] [Citation(s) in RCA: 60] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
PURPOSE We aimed to establish the prevalence of different Burkholderia species among UK cystic fibrosis (CF) and non-CF patients over a 2 year period. METHODOLOGY Matrix-assisted laser desorption/ionization-time of flight mass spectrometry was used to identify isolates to genus level, followed by recA/gyrB sequence clustering or species-specific PCR. In all, 1047 Burkholderia isolates were submitted for identification from 361 CF patients and 112 non-CF patients, 25 from the hospital environment and three from a commercial company. Potential cross-infection was assessed by pulsed-field gel electrophoresis (PFGE) and multi- locus-sequence typing (MLST). MICs were determined for 161 Burkholderia cepacia complex (Bcc) isolates. CF Trust registry data were sought to examine clinical parameters relating to Bcc infection. RESULTS Burkholderia multivorans was the most prevalent species among CF patients affecting 56 % (192) patients, followed by Burkholderia cenocepacia IIIA (15 %; 52 patients). Five novel recA clusters were found. Among non-CF patients, Burkholderia cepacia was the most prevalent species (37/112; 34 %), with 18 of 40 isolates part of a UK-wide B. cepacia 'cluster'. This and three other clusters were investigated by PFGE and MLST. Cable-pili positive isolates included two novel sequence types and representatives of ET12. Antibiotic susceptibility varied between and within species and CF/non- CF isolates. CF Trust registry data suggested no significant difference in lung function between patients harbouring B. cenocepacia, B. multivorans and other Bcc species (P=0.81). CONCLUSION The dominance of B. multivorans in CF, the presence of a B. cepacia cluster among non-CF patients and the existence of putative novel species all highlighted the continuing role of Burkholderia species as opportunistic pathogens.
Collapse
Affiliation(s)
- Dervla T D Kenna
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Daniel Lilley
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Amy Coward
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Kate Martin
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Claire Perry
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Rachel Pike
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Robert Hill
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| | - Jane F Turton
- Antimicrobial Resistance and Healthcare Associated Infections (AMRHAI) Reference Unit, National Infection Service, Public Health England, 61 Colindale Avenue, London NW9 5EQ, UK
| |
Collapse
|
21
|
JOURNAL CLUB: Ultrasound-Guided Breast Interventions: Low Incidence of Infectious Complications With Use of an Uncovered Probe. AJR Am J Roentgenol 2017; 208:1147-1153. [PMID: 28225634 DOI: 10.2214/ajr.16.16440] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the incidence of infectious complications after ultrasound-guided breast interventions performed with an intermediate-level disinfection protocol without an ultrasound probe cover. MATERIALS AND METHODS Two independent institutional databases were searched to identify breast infections in patients who underwent ultrasound-guided interventions between January 2005 and July 2013. The departments of radiology and infectious diseases independently maintained these databases. A comprehensive retrospective chart review based on periprocedural antibiotic use and clinical documentation of infection was also performed to reduce the likelihood of missing potential infectious complications. RESULTS A total of 12,708 ultrasound-guided breast procedures were performed in the time frame of this study. All potential cases of procedure-related infection were included for subspecialist review in an effort to give the most conservative (highest) estimate of infectious complications. Among these cases, 14 documented cases of possible procedure-related infection were identified, for an overall incidence of 0.11%. All infections were localized skin or soft-tissue infections and adequately treated with a short course of oral antibiotics. No cases of more serious infections or sepsis were found. None of the reported infections required IV antibiotic therapy, percutaneous intervention, surgical intervention, or hospitalization. CONCLUSION The incidence of infectious complications after an ultrasound-guided breast intervention without an ultrasound probe cover is extremely low. Physicians can use this information in the development of their disinfection protocols and to provide accurate information in counseling patients during preprocedural consultation.
Collapse
|
22
|
An Outbreak of Burkholderia cepacia Complex Infections Associated with Contaminated Liquid Docusate. Infect Control Hosp Epidemiol 2017; 38:567-573. [PMID: 28166854 DOI: 10.1017/ice.2017.11] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE To investigate an outbreak of Burkholderia cepacia complex and describe the measures that revealed the source. SETTING A 629-bed, tertiary-care, pediatric hospital in Houston, Texas. PATIENTS Pediatric patients without cystic fibrosis (CF) hospitalized in the pediatric and cardiovascular intensive care units. METHODS We investigated an outbreak of B. cepacia complex from February through July 2016. Isolates were evaluated for molecular relatedness with repetitive extragenic palindromic polymerase chain reaction (rep-PCR); specific species identification and genotyping were performed at an independent laboratory. The investigation included a detailed review of all cases, direct observation of clinical practices, and respiratory surveillance cultures. Environmental and product cultures were performed at an accredited reference environmental microbiology laboratory. RESULTS Overall, 18 respiratory tract cultures, 5 blood cultures, 4 urine cultures, and 3 stool cultures were positive in 24 patients. Among the 24 patients, 17 had symptomatic infections and 7 were colonized. The median age of the patients was 22.5 months (range, 2-148 months). Rep-PCR typing showed that 21 of 24 cases represented the same strain, which was identified as a novel species within the B. cepacia complex. Product cultures of liquid docusate were positive with an identical strain of B. cepacia complex. Local and state health departments, as well as the CDC and FDA, were notified, prompting a multistate investigation. CONCLUSIONS Our investigation revealed an outbreak of a unique strain of B. cepacia complex isolated in clinical specimens from non-CF pediatric patients and from liquid docusate. This resulted in a national alert and voluntary recall by the manufacturer. Infect Control Hosp Epidemiol 2017;38:567-573.
Collapse
|
23
|
|
24
|
Westerway SC, Basseal JM. The ultrasound unit and infection control - Are we on the right track? ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2017; 25:53-57. [PMID: 28228825 DOI: 10.1177/1742271x16688720] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 10/18/2016] [Accepted: 12/13/2016] [Indexed: 11/15/2022]
Abstract
Best practice guidelines for the disinfection of ultrasound transducers and infection prevention in ultrasound departments are generally recommended by either government health groups or the ultrasound societies of individual countries. The literature shows a wide variance in not only transducer cleaning methods but basic hygiene practices in the ultrasound workplace. This paper describes results from a UK survey of disinfection of ultrasound transducers and hygiene practice in the workplace. The survey revealed that some ultrasound practitioners did not follow current guidelines with regard to the correct disinfection method of transducers, cords or ultrasound machine keyboards. Furthermore, the survey exposed the lack of training from the product manufacturers on how to use the disinfection product appropriately. These inconsistencies may be responsible for compliance issues and highlight the need for an awareness campaign and a unified approach to infection control by ultrasound practitioners.
Collapse
Affiliation(s)
- Susan C Westerway
- Faculty of Dentistry & Health Sciences, Charles Sturt University, NSW, Australia; Australasian Society for Ultrasound in Medicine (ASUM), Sydney, NSW, Australia
| | - Jocelyne M Basseal
- Australasian Society for Ultrasound in Medicine (ASUM), Sydney, NSW, Australia
| |
Collapse
|
25
|
Nyhsen CM, Humphreys H, Nicolau C, Mostbeck G, Claudon M. Infection prevention and ultrasound probe decontamination practices in Europe: a survey of the European Society of Radiology. Insights Imaging 2016; 7:841-847. [PMID: 27778309 PMCID: PMC5110482 DOI: 10.1007/s13244-016-0528-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2016] [Revised: 09/19/2016] [Accepted: 10/03/2016] [Indexed: 11/26/2022] Open
Abstract
OBJECTIVES Although ultrasound (US) is considered one of the safest imaging modalities, concerns have been raised regarding potential infection transmission risks through US procedures. A survey was undertaken by the European Society of Radiology (ESR) to establish infection prevention and control measures in US and to highlight the importance of good medical practice. METHODS An online survey was sent to all 22,000 full ESR members. RESULTS The response rate of completed surveys was 4.3 % (946 practitioners, 97 % of which were radiologists, mostly working in larger hospital settings). Among respondents, 29 %, 11 % and 6 % did not disinfect the US probe after every patient when performing standard surface US, endo-cavity US and interventional procedures, respectively. Eleven percent did not always use probe covers for endo-cavity US; for interventional procedures, the proportion was 23 %. A minority used sterile gel sachets in direct patient contact for endo-cavity scans (30 %), and 77.5 % used sterile gel for interventional procedures. CONCLUSIONS The survey results highlight a wide range of practices throughout Europe and the need to raise awareness amongst practitioners regarding the importance of infection prevention and control measures. The development of European recommendations encompassing all US examinations, together with education is a priority. MAIN MESSAGES • Transmission of infection through ultrasound procedures is possible. • There is a wide range of ultrasound probe decontamination practices in Europe. • Not all practitioners use probe covers for endo-cavity or interventional ultrasound. • Not all practitioners use sterile gel for internal and invasive procedures. • Currently there are no European recommendations encompassing all US examinations.
Collapse
Affiliation(s)
| | - Hilary Humphreys
- Royal College of Surgeons in Ireland, RCSI Education & Research Centre, Beaumont Hospital, Beaumont Dublin 9, Ireland
| | - Carlos Nicolau
- Hospital Clinic de Barcelona, Villarroel 170, ES 8036 Barcelona, Spain
| | | | - Michel Claudon
- Radiology Department, Hôpital de Brabois, CHRU de Nancy and IADI INSERM U 947, Rue du Morvan, FR 54511 Vandoeuvre Les Nancy Cedex, France
| |
Collapse
|
26
|
Dietrich CF, Horn R, Morf S, Chiorean L, Dong Y, Cui XW, Atkinson NSS, Jenssen C. Ultrasound-guided central vascular interventions, comments on the European Federation of Societies for Ultrasound in Medicine and Biology guidelines on interventional ultrasound. J Thorac Dis 2016; 8:E851-E868. [PMID: 27747022 DOI: 10.21037/jtd.2016.08.49] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Central venous access has traditionally been performed on the basis of designated anatomical landmarks. However, due to patients' individual anatomy and vessel pathology and depending on individual operators' skill, this landmark approach is associated with a significant failure rate and complication risk. There is substantial evidence demonstrating significant improvement in effectiveness and safety of vascular access by realtime ultrasound (US)-guidance, as compared to the anatomical landmark-guided approach. This review comments on the evidence-based recommendations on US-guided vascular access which have been published recently within the framework of Guidelines on Interventional Ultrasound (InVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) from a clinical practice point of view.
Collapse
Affiliation(s)
- Christoph F Dietrich
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Sino-German Research Center of Ultrasound in Medicine, The First Affiliated Hospital of Zhengzhou University, Zhengzhou 450000, China
| | - Rudolf Horn
- Notfallstation, Kantonsspital Glarus, Glarus, Switzerland
| | - Susanne Morf
- Intensivmedizin Kantonsspital Graubünden, Chur, Switzerland
| | - Liliana Chiorean
- Department of Medical Imaging, des Cévennes Clinic, Annonay, France
| | - Yi Dong
- Translational Gastroenterology Unit, John Radcliffe Hospital, Oxford University Hospitals NHS Trust, Oxford, UK
| | - Xin-Wu Cui
- Medical Department, Caritas-Krankenhaus Bad Mergentheim, Academic Teaching Hospital of the University of Würzburg, Würzburg, Germany;; Department of Medical Ultrasound, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Nathan S S Atkinson
- Department of Ultrasound, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Christian Jenssen
- Department of Internal Medicine, Krankenhaus Märkisch Oderland Strausberg, Wriezen, Germany
| |
Collapse
|
27
|
Abstract
BACKGROUND Sterile and clean working conditions are one of the keystones of medical practice and this is also true for ultrasound-guided regional anesthesia. The routine clinical practice in ultrasound-guided regional anesthesia does not always comply with the principles of sterile and clean working conditions in medicine: therefore, patients are exposed to potential hazards regarding the transmission of pathogens via the ultrasound equipment. OBJECTIVE This article deals with the question of whether sterile working conditions in ultrasound-guided regional anesthesia are a relevant topic with medical and economic implications. Is it possible to implement the general recommendations for sterile working conditions in ultrasonography for the specific application of ultrasound-guided regional anesthesia? MATERIAL AND METHODS A search of the available literature and published guidelines in the field of sterile working conditions with ultrasound was carried out. RESULTS The association between cross-infections and ultrasound equipment is undeniable. Many methods for cleansing and disinfection of ultrasound equipment have been published. All these methods are associated with advantages and disadvantages. The direct sterilization of ultrasound probes with high-percentage alcohol can damage ultrasound probes (especially linear). The use of self-adhesive sterile ultrasound probe covers is a practical method to achieve sterile working conditions in ultrasound-guided regional anesthesia. CONCLUSION The use of sterile ultrasound probe covers and sterile ultrasound contact media is an important prerequisite to avoid cross-infection between patients. An appropriate scientific evaluation should serve as evidence in this field.
Collapse
|
28
|
Marhofer P, Fritsch G. Sterile working in ultrasonography: the use of dedicated ultrasound covers and sterile ultrasound gel. Expert Rev Med Devices 2015; 12:667-73. [PMID: 26325163 DOI: 10.1586/17434440.2015.1084872] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Ultrasound is currently an important tool for diagnostic and interventional procedures. Ultrasound imaging provides significant advantages as compared to other imaging methods. The widespread use of ultrasound also carries the risk of drawbacks such as cross-infections. A large body of literature reports this possibly life-threatening side effect and specific patient populations are particularly at risk (e.g., neonates). Various methods of ultrasound probe disinfection are described; however, none of the mechanical or chemical probe disinfection procedures is optimal and, in particular, disinfection with high concentration of alcohol might be associated with ultrasound probe damage. The preparation of ultrasound probes with dedicated probe covers is a useful alternative for sterile working conditions. One ultrasound probe cover discussed in this paper is directly glued on to the ultrasound probe without the use of ultrasound coupling gel. By the use of sterile ultrasound coupling gel at the outer surface, additional effects on aseptic working conditions can be obtained.
Collapse
Affiliation(s)
- Peter Marhofer
- a 1 Department of Anaesthesia, Intensive Care Medicine and Pain Therapy, Medical University of Vienna , A-1090 Vienna, Austria
| | - Gerhard Fritsch
- b 2 Department of Anesthesiology, Perioperative Medicine, and Critical Care Medicine, Paracelsus Medical University , Salzburg, Austria
| |
Collapse
|
29
|
O’Rourke M, Levan P, Khan T. Current Use of Ultrasound Transmission Gel for Transesophageal Echocardiogram Examinations: A Survey of Cardiothoracic Anesthesiology Fellowship Directors. J Cardiothorac Vasc Anesth 2014; 28:1208-10. [DOI: 10.1053/j.jvca.2014.02.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/17/2013] [Indexed: 11/11/2022]
|
30
|
Investigation of current infection-control practices for ultrasound coupling gel: a survey, microbiological analysis, and examination of practice patterns. Reg Anesth Pain Med 2014; 38:415-24. [PMID: 23974866 DOI: 10.1097/aap.0b013e3182a0e12f] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND AND OBJECTIVES Ultrasound coupling gel may serve as a vector for the spread of bacteria and has been the causative agent for significant health care-associated infections. The purpose of this study was to document existing infection-control procedures and level of contamination present within nonsterile ultrasound gel from several clinical departments at a single institution. A second purpose was to examine the effectiveness of clinician education and manufacturer-based ultrasound additives on ultrasound gel contamination and in vitro bacterial proliferation, respectively. METHODS Compliance with Health Canada recommended infection-control policies were determined by survey. Contamination of in-use ultrasound gel bottles was determined by inspecting cultures after 72 hours of incubation. After infection-control education, a 28-day interval assessment was used to examine contamination rates in newly provided ultrasound gel. The ability of ultrasound gel containing parabens to prevent bacterial growth was examined in cultures grown with and without ultrasound gel. RESULTS Practitioners were not compliant with Health Canada recommendations, but the baseline ultrasound gel contamination rate within these departments was only 2.5%. Education in infection control did not improve the contamination rate over 28 days. Contamination was discovered in ultrasound gel supplied directly from the manufacturer. Ultrasound gel suppressed but did not prevent bacterial growth in a species- and time-specific manner. CONCLUSIONS The source of contamination for in-use ultrasound gel may be of manufacturer or human origin. Because additives to the ultrasound gel are not bactericidal, sterile ultrasound gel should be used for invasive and high-risk cases, and improving infection-control policies is warranted.
Collapse
|
31
|
Souza Dias MB, Cavassin LG, Stempliuk V, Xavier LS, Lobo RD, Sampaio JL, Pignatari AC, Borrasca VL, Bierrenbach AL, Toscano CM. Multi-institutional outbreak of Burkholderia cepacia complex associated with contaminated mannitol solution prepared in compounding pharmacy. Am J Infect Control 2013; 41:1038-42. [PMID: 23663863 DOI: 10.1016/j.ajic.2013.01.033] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2012] [Revised: 01/17/2013] [Accepted: 01/17/2013] [Indexed: 11/26/2022]
Abstract
BACKGROUND Burkholderia cepacia complex (BCC) has been described as a cause of nosocomial outbreaks. We describe an outbreak of and identify risk factors for nosocomial BCC infections associated with intrinsically contaminated mannitol 3% solution. METHODS Urinary and bloodstream infection caused by BCC were identified in hospitalized patients who underwent urologic surgery and received intraoperative irrigation of 3% mannitol solution in February 2009. The investigation included retrospective chart review, case control study, procedural review, and culture of mannitol solution. RESULTS Seven BCC infections were identified. BCC isolates were recovered from blood and/or urine from patients and lots of mannitol in use during the outbreak period. Mannitol solution was produced by a compounding pharmacy. Receipt of larger volumes of contaminated solution was identified as a significant risk factor for infection (odds ratio, 1.5; P value < .05). BCC was also cultured in lots of mannitol in use in other hospitals. CONCLUSION Manipulated mannitol solution is a potential source of infection. Contamination with paraben-degrading organisms can occur at the time of manufacture. Our findings suggest that contamination of mannitol at a compounding pharmacy occurred. Prompt communication to other hospitals and implementation of infection control measures were effective in avoiding further cases of infection.
Collapse
|
32
|
Chittick P, Russo V, Sims M, Robinson-Dunn B, Oleszkowicz S, Sawarynski K, Powell K, Makin J, Darnell E, Boura JA, Boyanton B, Band J. An outbreak of Pseudomonas aeruginosa respiratory tract infections associated with intrinsically contaminated ultrasound transmission gel. Infect Control Hosp Epidemiol 2013; 34:850-3. [PMID: 23838230 DOI: 10.1086/671268] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
We describe an outbreak of Pseudomonas aeruginosa respiratory tract infections related to intrinsically contaminated ultrasound gel used for intraoperative transesophageal echocardiograms in cardiovascular surgery patients. This investigation led to a product safety alert by the Food and Drug Administration and the development of guidelines for appropriate use of ultrasound gel.
Collapse
Affiliation(s)
- Paul Chittick
- Department of Infectious Disease, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
33
|
Oleszkowicz SC, Chittick P, Russo V, Keller P, Sims M, Band J. Infections associated with use of ultrasound transmission gel: proposed guidelines to minimize risk. Infect Control Hosp Epidemiol 2012; 33:1235-7. [PMID: 23143361 DOI: 10.1086/668430] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Affiliation(s)
- Susan C Oleszkowicz
- Department of Epidemiology, Beaumont Health System, Royal Oak, Michigan 48073, USA.
| | | | | | | | | | | |
Collapse
|
34
|
Pseudomonas aeruginosa Respiratory Tract Infections Associated With Contaminated Ultrasound Gel Used for Transesophageal Echocardiography—Michigan, December 2011–January 2012. Ann Emerg Med 2012; 60:374-6; discussion 376-7. [DOI: 10.1016/j.annemergmed.2012.07.106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
35
|
Identification, molecular characterisation and antimicrobial susceptibility of genomovars of the Burkholderia cepacia complex in Spain. Eur J Clin Microbiol Infect Dis 2012; 31:3385-96. [DOI: 10.1007/s10096-012-1707-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2012] [Accepted: 07/16/2012] [Indexed: 12/01/2022]
|
36
|
Gray RA, Williams PL, Dubbins PA, Jenks PJ. Decontamination of transvaginal ultrasound probes: review of national practice and need for national guidelines. Clin Radiol 2012; 67:1069-77. [PMID: 22591688 DOI: 10.1016/j.crad.2012.02.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2011] [Revised: 02/05/2012] [Accepted: 02/13/2012] [Indexed: 12/01/2022]
Abstract
AIM To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. MATERIALS AND METHODS A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. RESULTS There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. CONCLUSION While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.
Collapse
Affiliation(s)
- R A Gray
- Derriford Hospital, Crownhill, Plymouth, Devon, UK.
| | | | | | | |
Collapse
|
37
|
Coutinho CP, dos Santos SC, Madeira A, Mira NP, Moreira AS, Sá-Correia I. Long-term colonization of the cystic fibrosis lung by Burkholderia cepacia complex bacteria: epidemiology, clonal variation, and genome-wide expression alterations. Front Cell Infect Microbiol 2011; 1:12. [PMID: 22919578 PMCID: PMC3417363 DOI: 10.3389/fcimb.2011.00012] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2011] [Accepted: 11/15/2011] [Indexed: 01/06/2023] Open
Abstract
Long-term respiratory infections with Burkholderia cepacia complex (Bcc) bacteria in cystic fibrosis (CF) patients generally lead to a more rapid decline in lung function and, in some cases, to a fatal necrotizing pneumonia known as the "cepacia syndrome." Bcc bacteria are ubiquitous in the environment and are recognized as serious opportunistic pathogens that are virtually impossible to eradicate from the CF lung, posing a serious clinical threat. The epidemiological survey of Bcc bacteria involved in respiratory infections at the major Portuguese CF Treatment Center at Santa Maria Hospital, in Lisbon, has been carried out by our research group for the past 16 years, covering over 500 clinical isolates where B. cepacia and B. cenocepacia are the predominant species, with B. stabilis, B. contaminans, B. dolosa, and B. multivorans also represented. The systematic and longitudinal study of this CF population during such an extended period of time represents a unique case-study, comprehending 41 Bcc-infected patients (29 pediatric and 12 adult) of whom around 70% have been persistently colonized between 7 months and 9 years. During chronic infection, the CF airways represent an evolving ecosystem, with multiple phenotypic variants emerging from the clonal population and becoming established in the patients' airways as the result of genetic adaptation. Understanding the evolutionary mechanisms involved is crucial for an improved therapeutic outcome of chronic infections in CF. This review focuses on our contribution to the understanding of these adaptive mechanisms based on extensive phenotypic, genotypic, and genome-wide expression approaches of selected Bcc clonal variants obtained during long-term colonization of the CF airways.
Collapse
Affiliation(s)
- Carla P. Coutinho
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| | - Sandra C. dos Santos
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| | - Andreia Madeira
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
- Department of Bioengineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| | - Nuno P. Mira
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| | - Ana S. Moreira
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| | - Isabel Sá-Correia
- Institute for Biotechnology and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
- Department of Bioengineering, Instituto Superior Técnico, Technical University of LisbonLisbon, Portugal
| |
Collapse
|
38
|
Lucero CA, Cohen AL, Trevino I, Rupp AH, Harris M, Forkan-Kelly S, Noble-Wang J, Jensen B, Shams A, Arduino MJ, LiPuma JJ, Gerber SI, Srinivasan A. Outbreak of Burkholderia cepacia complex among ventilated pediatric patients linked to hospital sinks. Am J Infect Control 2011; 39:775-8. [PMID: 21664002 DOI: 10.1016/j.ajic.2010.12.005] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 12/01/2010] [Accepted: 12/03/2010] [Indexed: 01/24/2023]
Abstract
We investigated a cluster of Burkholderia cepacia complex colonization in ventilated pediatric patients. Isolates from 15 patients, 2 sink drains, and several ventilator components were found to belong to a single B cenocepacia clone. Hospital tap water used during oral and tracheostomy care was identified as the most likely mechanism for transmission.
Collapse
|
39
|
Ultrasound echocardiographic gel contamination by Burkholderia cepacia in an Italian hospital. J Hosp Infect 2011; 76:360-1. [PMID: 20970887 DOI: 10.1016/j.jhin.2010.07.017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2010] [Accepted: 07/29/2010] [Indexed: 10/18/2022]
|
40
|
Olshtain-Pops K, Block C, Temper V, Hidalgo-Grass C, Gross I, Moses AE, Gofrit ON, Benenson S. An outbreak of achromobacter xylosoxidans associated with ultrasound gel used during transrectal ultrasound guided prostate biopsy. J Urol 2010; 185:144-7. [PMID: 21074197 DOI: 10.1016/j.juro.2010.08.093] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2010] [Indexed: 10/18/2022]
Abstract
PURPOSE We describe an outbreak of Achromobacter xylosoxidans after transrectal ultrasound guided prostate biopsy at a urology unit at a tertiary care center as well as clinical and microbiological investigation, and intervention. MATERIALS AND METHODS In September 2008, several days after undergoing transrectal ultrasound guided prostate biopsy, 4 patients were hospitalized with fever. We reviewed the procedure and infection control practices in the urology service. Environmental cultures were obtained from equipment and materials used for the procedure. Isolates were identified by routine laboratory procedures with molecular confirmation and characterized by pulsed field gel electrophoresis. RESULTS A. xylosoxidans was isolated from the urine of 2 patients, of whom 1 also had a positive blood culture. Review of transrectal ultrasound guided prostate biopsy revealed that the lubricant gel used in the procedure, which the biopsy needle passes through, was held in a plastic container that was repeatedly refilled from a large bag. A. xylosoxidans was isolated from this container. Pulsed field gel electrophoresis showed that the isolates obtained from patients and the gel were identical. CONCLUSIONS Contaminated lubricant gel was the cause of this outbreak. The practice of repeatedly refilling gel containers with nonsterile gel was replaced by the use of individual sterile gel sachets in each patient. No further cases occurred. During an invasive procedure involving a sterile body site, such as transrectal ultrasound guided prostate biopsy, using sterile gel is essential. Our experience emphasizes the crucial need to review all invasive procedures from an infection control perspective.
Collapse
Affiliation(s)
- Karen Olshtain-Pops
- Department of Clinical Microbiology and Infectious Diseases, Hadassah-Hebrew University Medical Center, Jerusalem, Israel
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Scheans P. Is your nursery full of MDROs? Neonatal Netw 2010; 29:392-395. [PMID: 21071366 DOI: 10.1891/0730-0832.29.6.392] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Multidrug-resistant organisms (MDROs) or multiresistant organisms are a significant and growing concern to all of us. Late-onset methicillin-resistant Staphylococcus aureus (MRSA) infections in the NICU are reported to have increased by 308 percent from 1995 to 2004.1 The Centers for Disease Control and Prevention (CDC) Healthcare Infection Control Practices Advisory Committee considers the prevention and control of MDROs a national priority, one that requires administrative and scientific leadership. This campaign will take commitment of financial resources, as well as of human resources devoted to practice improvement, expert consultation, laboratory support, monitoring of adherence to the practices that help with the problem, and data analysis.2 Unfortunately, this trend holds in developing countries as well. MDROs are a clinical challenge the world over.
Collapse
|
42
|
Epidemiology and molecular characterization of a clone of Burkholderia cenocepacia responsible for nosocomial pulmonary tract infections in a French intensive care unit. Diagn Microbiol Infect Dis 2010; 66:29-40. [DOI: 10.1016/j.diagmicrobio.2009.06.008] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2009] [Revised: 06/04/2009] [Accepted: 06/08/2009] [Indexed: 11/17/2022]
|
43
|
Heo ST, Kim SJ, Jeong YG, Bae IG, Jin JS, Lee JC. Hospital outbreak of Burkholderia stabilis bacteraemia related to contaminated chlorhexidine in haematological malignancy patients with indwelling catheters. J Hosp Infect 2009; 70:241-5. [PMID: 18799235 DOI: 10.1016/j.jhin.2008.07.019] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2008] [Accepted: 07/24/2008] [Indexed: 10/21/2022]
Abstract
Burkholderia cepacia complex (BCC) is an opportunistic pathogen that occasionally causes hospital outbreaks. This paper describes an outbreak of BCC bacteraemia in haematological malignancy patients related to a contaminated chlorhexidine gluconate solution. Eight BCC isolates were obtained from patients hospitalised in the same ward of a cancer centre in a Korean hospital. A further three BCC isolates were obtained from 0.5% chlorhexidine gluconate used in the same ward. The isolates were identified as B. stabilis and exhibited identical pulsed-field gel electrophoresis profiles. All patients with B. stabilis bacteraemia had indwelling intravenous catheters, which were treated with chlorhexidine to disinfect the catheters. Following identification of the source of contamination, strict controls regarding surveillance cultures for disinfectants have been enforced. No further B. stabilis infections have been found in the hospital.
Collapse
Affiliation(s)
- S T Heo
- Department of Internal Medicine, Gyeongsang National University School of Medicine, Jinju, Korea
| | | | | | | | | | | |
Collapse
|
44
|
Smole I, Thomann A, Frey J, Perreten V. Repression of common bull sperm flora and in vitro impairment of sperm motility with Pseudomonas aeruginosa introduced by contaminated lubricant. Reprod Domest Anim 2009; 45:737-42. [PMID: 19144031 DOI: 10.1111/j.1439-0531.2008.01319.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Semen collected from clinically healthy bulls at an artificial insemination centre was examined for bacterial diversity. While bacteria that are normally present in the common flora of bovine semen were absent, such as Mycoplasma sp., Proteus sp. and Corynebacterium sp., all semen samples contained an unusually high number of Pseudomonas aeruginosa strains. Analysis via pulsed field gel electrophoresis demonstrated that one particular P. aeruginosa strain, present in a sealed bottle of lubricant, was widespread in bull semen. This strain was shown to secrete substances that inhibited both the growth of bacteria constituting the normal bull sperm flora and the motility of spermatozoa in vitro. This study demonstrated that commercially available lubricants might contain bacteria that can spread amongst breeding bulls and affect the quality of semen. Bacteriological controls and species' identification are necessary at several production levels, including lubricants and extenders, to ensure high semen quality and avoid the spread of pathogens.
Collapse
Affiliation(s)
- I Smole
- Institute of Veterinary Bacteriology, Vetsuisse Faculty, University of Berne, Berne, Switzerland
| | | | | | | |
Collapse
|
45
|
Yan H, Shi L, Alam M, Li L, Yang L, Yamasaki S. Usefulness of Sau-PCR for molecular epidemiology of nosocomial outbreaks due to Burkholderia cepacia which occurred in a local hospital in Guangzhou, China. Microbiol Immunol 2008; 52:283-6. [DOI: 10.1111/j.1348-0421.2008.00035.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
46
|
Irwin AE, Price CS. More than skin deep: moisturizing body milk and Burkholderia cepacia. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2008; 12:115. [PMID: 18304377 PMCID: PMC2374588 DOI: 10.1186/cc6781] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Alvarez-Lerma and colleagues observed over an 18-day period that five critically ill patients admitted to a multidisciplinary 18-bed intensive care unit contracted Burkholderia cepacia from unopened containers of moisturizing body milk, calling into question the use in critical care settings of cosmetic products that do not guarantee sterilization during the manufacturing process. Is this the answer to the problem, however, or should the use of lotions in such settings be re-examined?
Collapse
|
47
|
Cunha MV, Pinto-de-Oliveira A, Meirinhos-Soares L, Salgado MJ, Melo-Cristino J, Correia S, Barreto C, Sá-Correia I. Exceptionally high representation of Burkholderia cepacia among B. cepacia complex isolates recovered from the major Portuguese cystic fibrosis center. J Clin Microbiol 2007; 45:1628-33. [PMID: 17360834 PMCID: PMC1865859 DOI: 10.1128/jcm.00234-07] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2007] [Revised: 03/02/2007] [Accepted: 03/07/2007] [Indexed: 11/20/2022] Open
Abstract
Burkholderia cepacia, a species found infrequently in cystic fibrosis (CF), was isolated from 85% of patients infected with bacteria of the B. cepacia complex that visited the major Portuguese CF center, in Lisbon, during 2003 to 2005. A detailed molecular analysis revealed that this was mainly due to two B. cepacia clones. These clones were indistinguishable from two strains isolated from intrinsically contaminated nonsterile saline solutions for nasal application, detected during routine market surveillance by the Portuguese Medicines and Health Products Authority.
Collapse
Affiliation(s)
- Mónica V Cunha
- IBB-Institute for Biological and Bioengineering, Centre for Biological and Chemical Engineering, Instituto Superior Técnico, Av. Rovisco Pais, 1049-001 Lisboa, Portugal
| | | | | | | | | | | | | | | |
Collapse
|