Dorst J, Ruhm L, Avdievich N, Bogner W, Henning A. Comparison of four 31P single-voxel MRS sequences in the human brain at 9.4 T. Magn Reson Med 2021; 85:3010-3026. [PMID: 33427322 DOI: 10.1002/mrm.28658] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2020] [Revised: 12/03/2020] [Accepted: 12/06/2020] [Indexed: 01/30/2023]
Abstract
PURPOSE In this study, different single-voxel localization sequences were implemented and systematically compared for the first time for phosphorous MRS (31 P-MRS) in the human brain at 9.4 T. METHODS Two multishot sequences, image-selected in vivo spectroscopy (ISIS) and a conventional slice-selective excitation combined with localization by adiabatic selective refocusing (semiLASER) variant of the spin-echo full intensity-acquired localized spectroscopy (SPECIAL-semiLASER), and two single-shot sequences, semiLASER and stimulated echo acquisition mode (STEAM), were implemented and optimized for 31 P-MRS in the human brain at 9.4 T. Pulses and coil setup were optimized, localization accuracy was tested in phantom experiments, and absolute SNR of the sequences was compared in vivo. The SNR per unit time (SNR/t) was derived and compared for all four sequences and verified experimentally for ISIS in two different voxel sizes (3 × 3 × 3 cm3 , 5 × 5 × 5 cm3 , 10-minute measurement time). Metabolite signals obtained with ISIS were quantified. The possible spectral quality in vivo acquired in clinically feasible time (3:30 minutes, 3 × 3 × 3 cm3 ) was explored for two different coil setups. RESULTS All evaluated sequences performed with good localization accuracy in phantom experiments and provided well-resolved spectra in vivo. However, ISIS has the lowest chemical shift displacement error, the best localization accuracy, the highest SNR/t for most metabolites, provides metabolite concentrations comparable to literature values, and is the only one of the sequences that allows for the detection of the whole 31 P spectrum, including β-adenosine triphosphate, with the used setup. The SNR/t of STEAM is comparable to the SNR/t of ISIS. The semiLASER and SPECIAL-semiLASER sequences provide good results for metabolites with long T2 . CONCLUSION At 9.4 T, high-quality single-voxel localized 31 P-MRS can be performed in the human brain with different localization methods, each with inherent characteristics suitable for different research issues.
Collapse
Affiliation(s)
- Johanna Dorst
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Loreen Ruhm
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,IMPRS for Cognitive and Systems Neuroscience, University of Tübingen, Tübingen, Germany
| | - Nikolai Avdievich
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Wolfgang Bogner
- High-Field MR Center, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Anke Henning
- High-Field MR Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany.,Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, Texas, USA
| |
Collapse
|
2
|
Gajdošík M, Chadzynski GL, Hangel G, Mlynárik V, Chmelík M, Valkovič L, Bogner W, Pohmann R, Scheffler K, Trattnig S, Krššák M. Ultrashort-TE stimulated echo acquisition mode (STEAM) improves the quantification of lipids and fatty acid chain unsaturation in the human liver at 7 T. NMR IN BIOMEDICINE 2015; 28:1283-1293. [PMID: 26313737 DOI: 10.1002/nbm.3382] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2015] [Revised: 07/15/2015] [Accepted: 07/24/2015] [Indexed: 06/04/2023]
Abstract
Ultrahigh-field, whole-body MR systems increase the signal-to-noise ratio (SNR) and improve the spectral resolution. Sequences with a short TE allow fast signal acquisition with low signal loss as a result of spin-spin relaxation. This is of particular importance in the liver for the precise quantification of the hepatocellular content of lipids (HCL). In this study, we introduce a spoiler Gradient-switching Ultrashort STimulated Echo AcqUisition (GUSTEAU) sequence, which is a modified version of a stimulated echo acquisition mode (STEAM) sequence, with a minimum TE of 6 ms. With the high spectral resolution at 7 T, the efficient elimination of water sidebands and the post-processing suppression of the water signal, we estimated the composition of fatty acids (FAs) via the detection of the olefinic lipid resonance and calculated the unsaturation index (UI) of hepatic FAs. The performance of the GUSTEAU sequence for the assessment of UI was validated against oil samples and provided excellent results in agreement with the data reported in the literature. When measuring HCL with GUSTEAU in 10 healthy volunteers, there was a high correlation between the results obtained at 7 and 3 T (R(2) = 0.961). The test-retest measurements yielded low coefficients of variation for HCL (4 ± 3%) and UI (11 ± 8%) when measured with the GUSTEAU sequence at 7 T. A negative correlation was found between UI and HCL (n = 10; p < 0.033). The ultrashort TE MRS sequence (GUSTEAU; TE = 6 ms) provided high repeatability for the assessment of HCL. The improved spectral resolution at 7 T with the elimination of water sidebands and the offline water subtraction also enabled an assessment of the unsaturation of FAs. This all highlights the potential use of this MRS acquisition scheme for studies of hepatic lipid composition in vivo.
Collapse
Affiliation(s)
- Martin Gajdošík
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Grzegorz L Chadzynski
- Department of Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Gilbert Hangel
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Vladimír Mlynárik
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Marek Chmelík
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Ladislav Valkovič
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Wolfgang Bogner
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
| | - Rolf Pohmann
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Klaus Scheffler
- Department of Biomedical Magnetic Resonance, University of Tübingen, Tübingen, Germany
- High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
| | - Siegfried Trattnig
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Christian Doppler Laboratory for Clinical Molecular MR Imaging, Vienna, Austria
| | - Martin Krššák
- High-Field MR Center, Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria
- Division of Endocrinology and Metabolism, Department of Internal Medicine III, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
3
|
Valkovič L, Chmelík M, Just Kukurová I, Jakubová M, Kipfelsberger MC, Krumpolec P, Tušek Jelenc M, Bogner W, Meyerspeer M, Ukropec J, Frollo I, Ukropcová B, Trattnig S, Krššák M. Depth-resolved surface coil MRS (DRESS)-localized dynamic (31) P-MRS of the exercising human gastrocnemius muscle at 7 T. NMR IN BIOMEDICINE 2014; 27:1346-1352. [PMID: 25199902 DOI: 10.1002/nbm.3196] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/02/2014] [Revised: 07/04/2014] [Accepted: 07/31/2014] [Indexed: 06/03/2023]
Abstract
Dynamic (31) P-MRS with sufficiently high temporal resolution enables the non-invasive evaluation of oxidative muscle metabolism through the measurement of phosphocreatine (PCr) recovery after exercise. Recently, single-voxel localized (31) P-MRS was compared with surface coil localization in a dynamic fashion, and was shown to provide higher anatomical and physiological specificity. However, the relatively long TE needed for the single-voxel localization scheme with adiabatic pulses limits the quantification of J-coupled spin systems [e.g. adenosine triphosphate (ATP)]. Therefore, the aim of this study was to evaluate depth-resolved surface coil MRS (DRESS) as an alternative localization method capable of free induction decay (FID) acquisition for dynamic (31) P-MRS at 7 T. The localization performance of the DRESS sequence was tested in a phantom. Subsequently, two dynamic examinations of plantar flexions at 25% of maximum voluntary contraction were conducted in 10 volunteers, one examination with and one without spatial localization. The DRESS slab was positioned obliquely over the gastrocnemius medialis muscle, avoiding other calf muscles. Under the same load, significant differences in PCr signal drop (31.2 ± 16.0% versus 43.3 ± 23.4%), end exercise pH (7.06 ± 0.02 versus 6.96 ± 0.11), initial recovery rate (0.24 ± 0.13 mm/s versus 0.35 ± 0.18 mm/s) and maximum oxidative flux (0.41 ± 0.14 mm/s versus 0.54 ± 0.16 mm/s) were found between the non-localized and DRESS-localized data, respectively. Splitting of the inorganic phosphate (Pi) signal was observed in several non-localized datasets, but in none of the DRESS-localized datasets. Our results suggest that the application of the DRESS localization scheme yielded good spatial selection, and provided muscle-specific insight into oxidative metabolism, even at a relatively low exercise load. In addition, the non-echo-based FID acquisition allowed for reliable detection of ATP resonances, and therefore calculation of the specific maximum oxidative flux, in the gastrocnemius medialis using standard assumptions about resting ATP concentration in skeletal muscle.
Collapse
Affiliation(s)
- Ladislav Valkovič
- Department of Biomedical Imaging and Image-guided Therapy, Medical University of Vienna, Vienna, Austria; High Field MR Center, Medical University of Vienna, Vienna, Austria; Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Valkovič L, Bogner W, Gajdošík M, Považan M, Kukurová IJ, Krššák M, Gruber S, Frollo I, Trattnig S, Chmelík M. One-dimensional image-selected in vivo spectroscopy localized phosphorus saturation transfer at 7T. Magn Reson Med 2014; 72:1509-15. [PMID: 24470429 DOI: 10.1002/mrm.25058] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 10/30/2013] [Accepted: 11/05/2013] [Indexed: 01/07/2023]
Abstract
PURPOSE To evaluate the feasibility of a one-dimensional image-selected in vivo spectroscopy (1D-ISIS) saturation transfer (ST) sequence at 7T for localized in vivo measurements of energy metabolism in different tissues in clinically reasonable examination times. METHODS The performance of a gradient offset independent adiabacity-based 1D-ISIS localization was tested on phantom and the localized ST sequence was compared with the nonlocalized version in vivo. We performed localized measurements of basal metabolism of human liver and different muscle groups of the calf. Localized ST experiments took 15-25 minutes. RESULTS The selectivity of the 1D-ISIS sequence was 81.63% and the outer volume suppression was 97.57%. The ST parameters acquired with the 1D-ISIS sequence and with the nonlocalized acquisition in the muscle were not statistically different. The forward rate constants for phosphocreatine (PCr)-adenosine triphosphate (ATP) and inorganic phosphate (Pi)-ATP exchange reactions were measured in the soleus (kCK = 0.30 ± 0.06 s(-1) and kATP = 0.11 ± 0.02 s(-1) , respectively) and in the medial gastrocnemius (kCK = 0.27 ± 0.06 s(-1) and kATP = 0.09 ± 0.03s(-1) , respectively) in 15 minutes per muscle group. The corresponding fluxes were FCK = 6.26 ± 1.28 μmol/g/s, FATP = 0.22 ± 0.05 μmol/g/s and FCK = 6.29 ± 1.66 μmol/g/s, FATP = 0.21 ± 0.07 μmol/g/s, for soleus and gastrocnemius, respectively. The hepatic ATP synthesis measurement was feasible in 24 minutes. CONCLUSION The fast assessment of PCr-ATP and Pi-ATP exchange rates at 7T makes the 1D-ISIS ST sequence a promising tool for examining local resting-state metabolism in clinically acceptable measurement times.
Collapse
Affiliation(s)
- Ladislav Valkovič
- High Field MR Centre, Department of Biomedical Imaging and Image-guided Therapy, Medical University Vienna, Vienna, Austria; Department of Imaging Methods, Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Abstract
The ability to select a discrete region within the body for signal acquisition is a fundamental requirement of in vivo NMR spectroscopy. Ideally, it should be possible to tailor the selected volume to coincide exactly with the lesion or tissue of interest, without loss of signal from within this volume or contamination with extraneous signals. Many techniques have been developed over the past 25 years employing a combination of RF coil properties, static magnetic field gradients and pulse sequence design in an attempt to meet these goals. This review presents a comprehensive survey of these techniques, their various advantages and disadvantages, and implications for clinical applications. Particular emphasis is placed on the reliability of the techniques in terms of signal loss, contamination and the effect of nuclear relaxation and J-coupling. The survey includes techniques based on RF coil and pulse design alone, those using static magnetic field gradients, and magnetic resonance spectroscopic imaging. Although there is an emphasis on techniques currently in widespread use (PRESS, STEAM, ISIS and MRSI), the review also includes earlier techniques, in order to provide historical context, and techniques that are promising for future use in clinical and biomedical applications.
Collapse
Affiliation(s)
- Stephen F Keevil
- Department of Medical Physics, Guy's and St Thomas' NHS Foundation Trust, Guy's Hospital, London, SE1 9RT, UK.
| |
Collapse
|
6
|
Keevil SF, Newbold MC. The performance of volume selection sequences for in vivo NMR spectroscopy: implications for quantitative MRS. Magn Reson Imaging 2001; 19:1217-26. [PMID: 11755732 DOI: 10.1016/s0730-725x(01)00449-0] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Previous work has demonstrated that deficiencies in volume selection sequences used in magnetic resonance spectroscopy may compromise the quality of the spectra obtained. In this paper, further studies on the ISIS and PRESS sequences are presented. Under conditions of partial saturation, ISIS can exhibit serious contamination with extraneous signal, particularly when a small volume of interest (VOI) is selected. ISIS protocols should therefore use VOIs that are large relative to the target volume, and repetition times that are as long as practicable. In PRESS, contamination is found to be minimised by using a VOI that is small relative to the target volume, and to be independent of repetition time. PRESS performance is also independent of echo time, except when very short echo times are used. These results are consistent with previously published work on ISIS and PRESS, and it is now possible to establish generic features of these sequences and to understand the implications for quantitative spectroscopy. T(1)-weighting of contamination in ISIS can compromise both relative and absolute quantification techniques in several respects. Contamination in PRESS is largely independent of relaxation times and would be easier to model and correct for in the context of quantitative spectroscopy.
Collapse
Affiliation(s)
- S F Keevil
- Department of Radiological Sciences, Guy's, King's and St Thomas' School of Medicine, King's College London, Guy's Campus, London, SE1 9RT, UK.
| | | |
Collapse
|
7
|
Starck G, Ljungberg M, Vikhoff-Baaz B, Alpsten M, Ekholm S, Forssell-Aronsson E. Point-wise measurements of MRS volume selection performance are insensitive to magnetic susceptibility effects of phantom materials. Magn Reson Imaging 2000; 18:867-74. [PMID: 11027881 DOI: 10.1016/s0730-725x(00)00184-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
The purpose was to analyse magnetic susceptibility effects on accuracy of point-wise measurements of signal profiles in the assessment of MRS volume selection performance. An existing phantom design consisting of a sphere with a movable signal source was used for the investigation. The influence from the phantom on magnetic field homogeneity was measured with phase sensitive 1H imaging and 31P spectroscopy on a 1.5 T whole body MR system. The susceptibility effects for such a phantom design can be separated in 1/ A variation in the background magnetic field, which is caused by the stationary structures and has a significant influence on spatial accuracy. 2/ A magnetic field distortion, which is caused by the movable signal source and has very little influence on accuracy. The spatial inaccuracy due to susceptibility effects in this phantom, was 0.03 mm for positions of the signal source covering a 40-mm VOI. Susceptibility effects from the movable signal source were substantial but had very little influence on spatial accuracy. Still, improvements of this phantom design are possible. Point-wise measurements using a phantom with a movable signal source is inherently insensitive to susceptibility effects from the signal source and permits accurate signal profile measurements of high spatial (sub-mm) resolution.
Collapse
Affiliation(s)
- G Starck
- Division of Medical Physics and Medical Engineering, Sahlgrenska University Hospital, S-413 45, Göteborg, Sweden.
| | | | | | | | | | | |
Collapse
|
8
|
Burtscher IM, Johansson E, Holtås S, Ståhlberg F. Quality assessment of localization technique performance in small volume in vivo 1H MR spectroscopy. Magn Reson Imaging 1999; 17:1511-9. [PMID: 10610000 DOI: 10.1016/s0730-725x(99)00076-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A new phantom and evaluation method for experimental evaluation of 1H-magnetic resonance spectroscopy single volume localization techniques regarding signal contamination (C), defined as the part of the signal originating outside the volume of interest, is presented. The quality assessment method is based on a spherical phantom with an oil/water interface in order to reduce susceptibility effects, and applied for stimulated-echo acquisition method (STEAM) and spin-echo (SE) sequences, echo times of 270, 135, and 10 ms, and cubic volumes of interest (VOI) of 1(3), 1.5(3), 2(3), 2.5(3), and 3(3) cm3. To be able to mimic measurements of the contamination in three dimensions the physical gradients representing the three orthogonal directions for slice selection were shifted in the pulse sequences. Contamination values in one dimension differed between 6.5% and 8.4% in SE sequences, and between 0.7% and 13.8% in STEAM sequences. In STEAM sequences a decrease of C with increasing VOI size was observed while SE sequences showed comparable C values for the different VOI sizes tested. The total contamination in three dimensions were 19% and 18% in SE and STEAM sequences with a TE of 270 ms, and 7% in a STEAM sequence with a TE of 10 ms, respectively. The presented evaluation method is easily applied to the new phantom and showed high reproducibility.
Collapse
Affiliation(s)
- I M Burtscher
- Department of Radiology, University Hospital, Lund, Sweden.
| | | | | | | |
Collapse
|
9
|
Ljungberg M, Starck G, Vikhoff-Baaz B, Forssell-Aronsson E, Alpsten M, Ekholm S. Signal profile measurements of single- and double-volume acquisitions with image-selected in vivo spectroscopy for 31P magnetic resonance spectroscopy. Magn Reson Imaging 1998; 16:829-37. [PMID: 9811147 DOI: 10.1016/s0730-725x(98)00007-1] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2023]
Abstract
The volume-selection performance was studied for single- and double-volume-of-interest (VOI) acquisition with the volume-selection method image-selected in vivo spectroscopy for 31P magnetic resonance spectroscopy. High-resolution signal profiles were measured using a phantom simulating a brain. Inside the phantom there was a small, remotely controlled, movable signal source filled with ortho-phosphoric acid. Signal profiles of the VOI were measured in three perpendicular directions for 1VOI (single VOI) and 2VOI (double VOI) acquisition. The measured signal profiles for both acquisitions were very similar, but they showed a discrepancy with regard to the intended VOI (iVOI). The transition regions were on average 3.8 mm and the average full width at half maximum of the signal profile was 30 mm for an iVOI size of 30*30*30 (mm3). No displacement was observed in the signal profiles. To avoid overlapping signal profiles, the minimum separation between two iVOIs was found to be 10 mm in our magnetic resonance (MR) system. A substantial negative signal contribution from regions outside the iVOI was measured in the y-direction for 1VOI acquisition and one of the two VOIs in 2VOI acquisition. The other VOI in 2VOI acquisition exhibited only minor contamination. The measurements presented underline the importance of detailed knowledge on the volume selection performance in in vivo magnetic resonance spectroscopy.
Collapse
Affiliation(s)
- M Ljungberg
- Department of Radiation Physics, Göteborg University, Sahlgrenska University Hospital, Sweden.
| | | | | | | | | | | |
Collapse
|
10
|
Vikhoff B, Stubgaard M, Stensgaard A, Ståhlberg F, Henriksen O. A two-compartment phantom for VOI profile measurements in small-bore 31P MR spectroscopy. Phys Med Biol 1998; 43:1761-70. [PMID: 9651038 DOI: 10.1088/0031-9155/43/6/027] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
A two-compartment gel phantom for VOI profile measurements in volume-selective 31P spectroscopy in small-bore units is presented. The phantom is cylindrical with two compartments divided by a very thin (30 microm) polyethene film. This thin film permits measurements with a minimum of susceptibility influences from the partition wall. The phantom was used for evaluation of the volume selection method ISIS (image-selected in vivo spectroscopy). The position of the phantom was fixed in the magnet during the measurements, while the volume of interest (VOI) was moved stepwise over the border. The signal from the two compartments was measured for each position and the data were evaluated following differentiation. We have found this phantom suitable for VOI profile measurements of ISIS in small-bore systems. The phantom forms a useful complement to recommended phantoms for small bore-spectroscopy.
Collapse
Affiliation(s)
- B Vikhoff
- Department of Radiation Physics and Radiology, Lund University Hospital, Sweden
| | | | | | | | | |
Collapse
|
11
|
Ljungberg M, Starck G, Forssell-Aronsson E, Alpsten M, Ekholm S. Signal profile measurements for evaluation of the volume-selection performance of ISIS. NMR IN BIOMEDICINE 1995; 8:271-277. [PMID: 8732183 DOI: 10.1002/nbm.1940080607] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
High-resolution signal profiles obtained with a test phantom were used in this study to evaluate the volume-selection performance of an implementation of ISIS (Image Selected In vivo Spectroscopy). The phantom simulated the brain with regard to volume and loading of coil. A remotely controlled, movable signal source inside the phantom was filled with orthophosphoric acid. Signal profiles of the volume of interest (VOI) were measured in three perpendicular directions. Special interest was focused on the transition zones, the position of the profiles, and the effects of off-resonance and T1 smearing. The transition zones were on average 5.6 mm wide and the full width at half maximum (FWHM) was 35 mm for a VOI of 40 x 40 x 40 mm3. The positions of the centre of the signal profiles were x = 3.2, y = -0.7 and z = 3.3 mm off-centre. The deviation of the volume position could be explained by off-resonance effects during imaging and spectroscopy. These data illustrate the importance of detailed knowledge of the volume-selection performance when attempting precision measurements using image-guided in vivo MRS.
Collapse
Affiliation(s)
- M Ljungberg
- Department of Radiation Physics, Göteborg University, Sahlgrenska University Hospital, Sweden
| | | | | | | | | |
Collapse
|
12
|
Starck G, Lundin R, Forssell-Aronsson E, Arvidsson M, Alpsten M, Ekholm S. Evaluation of volume selection methods in in vivo MRS. Design of a new test phantom. Acta Radiol 1995; 36:317-22. [PMID: 7742130 DOI: 10.1177/028418519503600321] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Abstract
In vivo MR spectroscopy (MRS) requires some kind of volume selection method to be able to measure the signal from a selected part of the body. To be able to interpret the spectra correctly, the quality of the volume selection must be investigated for each new MRS application using phantom measurements. A new phantom, especially suitable for precision measurements of the volume selection performance, is presented. It contains a small, remotely controlled signal source placed inside a larger vessel. This principle can be applied to various body regions, coil types and nuclei. The measurement conditions are close to the clinical situation. The phantom does not have to be repositioned during a signal profile measurement and the signal contribution from each point along the profile is determined regarding sign and amplitude.
Collapse
Affiliation(s)
- G Starck
- Department of Radiation Physics, Sahlgren's Hospital, University of Gothenburg, Sweden
| | | | | | | | | | | |
Collapse
|
13
|
Bovée WM, Keevil SF, Leach MO, Podo F. Quality assessment in in vivo NMR spectroscopy: II. A protocol for quality assessment. EEC Concerted Research Project. Magn Reson Imaging 1995; 13:123-9. [PMID: 7898272 DOI: 10.1016/0730-725x(94)00088-k] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
A protocol has been developed for quality assessment in in vivo NMR spectroscopy (MRS) on whole body and animal systems. The protocol, which has been evaluated in a series of international trials, defines procedures, objects and substances to evaluate the localisation of common slice and volume selection sequences, and to assess other relevant aspects of system performance, including: signal-to-noise; signal loss; relation between signal strength, concentration and volume; selective suppression of spectral lines; spectrometer stability.
Collapse
Affiliation(s)
- W M Bovée
- Delft University of Technology, Physics Department, The Netherlands
| | | | | | | |
Collapse
|
14
|
Slotboom J, Bovée WMMJ. Adiabatic slice-selective rf pulses and a single-shot adiabatic localization pulse sequence. ACTA ACUST UNITED AC 1995. [DOI: 10.1002/cmr.1820070303] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
15
|
Bain PG, O'Brien MD, Keevil SF, Porter DA. Familial periodic cerebellar ataxia: a problem of cerebellar intracellular pH homeostasis. Ann Neurol 1992; 31:147-54. [PMID: 1575453 DOI: 10.1002/ana.410310205] [Citation(s) in RCA: 61] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Six affected members of two families with familial periodic cerebellar ataxia were relieved of their symptoms with oral acetazolamide. Phosphorus 31 (31P) nuclear magnetic resonance spectroscopy showed abnormal intracellular pH levels in the cerebellum of all subjects when they were not treated. These levels returned to normal with treatment. Cerebral pH values were also measured in one family and were normal before and after treatment. An additional 3 patients with similar attacks, but without a family history, had normal untreated pH values in the cerebellum and cerebrum.
Collapse
Affiliation(s)
- P G Bain
- Department of Neurology, UMDS, Guy's Hospital, London, UK
| | | | | | | |
Collapse
|
16
|
Slotboom J, Mehlkopf A, Bovée W. A single-shot localization pulse sequence suited for coils with inhomogeneous RF fields using adiabatic slice-selective RF pulses. ACTA ACUST UNITED AC 1991. [DOI: 10.1016/0022-2364(91)90229-m] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|