• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4671573)   Today's Articles (441)
For: Krmar M, Slivka J, Bikit I, Veskovic M, Conkic L, Bistrovic M, Rudic A. A new method for the measurement of bremsstrahlung spectra. Phys Med Biol 1999. [DOI: 10.1088/0031-9155/38/4/005] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Number Cited by Other Article(s)
1
Stamatelatos IE, Vasilopoulou T, Filippaki E, Georgolopoulou P, Ntalla E, Bassiakos Y. Photon activation analysis of large metallurgical slag samples using a 23 MV medical linear accelerator. J Radioanal Nucl Chem 2016. [DOI: 10.1007/s10967-016-4753-1] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
2
Ali ESM, Rogers DWO. An improved physics-based approach for unfolding megavoltage bremsstrahlung spectra using transmission analysis. Med Phys 2013;39:1663-75. [PMID: 22380398 DOI: 10.1118/1.3687164] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
3
Ali ESM, Rogers DWO. Functional forms for photon spectra of clinical linacs. Phys Med Biol 2011;57:31-50. [DOI: 10.1088/0031-9155/57/1/31] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
4
Scheithauer M, Schwedas M, Wiezorek T, Keller A, Wendt TG, Harder D. [Improvement of the accuracy of the Laplace transform method for the determination of radiotherapy spectra of clinical linear accelerators]. Z Med Phys 2003;13:22-9. [PMID: 12723520 DOI: 10.1078/0939-3889-00131] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
5
Sheikh-Bagheri D, Rogers DWO. Monte Carlo calculation of nine megavoltage photon beam spectra using the BEAM code. Med Phys 2002;29:391-402. [PMID: 11930914 DOI: 10.1118/1.1445413] [Citation(s) in RCA: 324] [Impact Index Per Article: 14.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
6
Stampanoni M, Fix M, Francois P, Rüegsegger P. Computer algebra for x-ray spectral reconstruction between 6 and 25 MV. Med Phys 2001;28:325-7. [PMID: 11318313 DOI: 10.1118/1.1350585] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA