Xiong T, Cai J, Zhou F, Liu B, Zhang J, Wu Q. An end-to-end deep convolutional neural network-based dose engine for parotid gland cancer seed implant brachytherapy. Med Phys 2024. [PMID: 38753975 DOI: 10.1002/mp.17123] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Revised: 04/12/2024] [Accepted: 04/29/2024] [Indexed: 05/18/2024] Open
Abstract
BACKGROUND Seed implant brachytherapy (SIBT) is a promising treatment modality for parotid gland cancers (PGCs). However, the current clinical standard dose calculation method based on the American Association of Physicists in Medicine (AAPM) Task Group 43 (TG-43) Report oversimplifies patient anatomy as a homogeneous water phantom medium, leading to significant dose calculation errors due to heterogeneity surrounding the parotid gland. Monte Carlo Simulation (MCS) can yield accurate dose distributions but the long computation time hinders its wide application in clinical practice. PURPOSE This paper aims to develop an end-to-end deep convolutional neural network-based dose engine (DCNN-DE) to achieve fast and accurate dose calculation for PGC SIBT. METHODS A DCNN model was trained using the patient's CT images and TG-43-based dose maps as inputs, with the corresponding MCS-based dose maps as the ground truth. The DCNN model was enhanced based on our previously proposed model by incorporating attention gates (AGs) and large kernel convolutions. Training and evaluation of the model were performed using a dataset comprising 188 PGC I-125 SIBT patient cases, and its transferability was tested on an additional 16 non-PGC head and neck cancers (HNCs) I-125 SIBT patient cases. Comparison studies were conducted to validate the superiority of the enhanced model over the original one and compare their overall performance. RESULTS On the PGC testing dataset, the DCNN-DE demonstrated the ability to generate accurate dose maps, with percentage absolute errors (PAEs) of 0.67% ± 0.47% for clinical target volume (CTV) D90 and 1.04% ± 1.33% for skin D0.1cc. The comparison studies revealed that incorporating AGs and large kernel convolutions resulted in 8.2% (p < 0.001) and 3.1% (p < 0.001) accuracy improvement, respectively, as measured by dose mean absolute error. On the non-PGC HNC dataset, the DCNN-DE exhibited good transferability, achieving a CTV D90 PAE of 1.88% ± 1.73%. The DCNN-DE can generate a dose map in less than 10 ms. CONCLUSIONS We have developed and validated an end-to-end DCNN-DE for PGC SIBT. The proposed DCNN-DE enables fast and accurate dose calculation, making it suitable for application in the plan optimization and evaluation process of PGC SIBT.
Collapse
Affiliation(s)
- Tianyu Xiong
- Image Processing Center, Beihang University, Beijing, People's Republic of China
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, People's Republic of China
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, People's Republic of China
| | - Fugen Zhou
- Image Processing Center, Beihang University, Beijing, People's Republic of China
| | - Bo Liu
- Image Processing Center, Beihang University, Beijing, People's Republic of China
| | - Jie Zhang
- Department of Oral and Maxillofacial Surgery, Peking University School of Stomatology, Beijing, People's Republic of China
| | - Qiuwen Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
2
|
Xiao Z, Xiong T, Geng L, Zhou F, Liu B, Sun H, Ji Z, Jiang Y, Wang J, Wu Q. Automatic planning for head and neck seed implant brachytherapy based on deep convolutional neural network dose engine. Med Phys 2024; 51:1460-1473. [PMID: 37757449 DOI: 10.1002/mp.16760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 08/30/2023] [Accepted: 09/15/2023] [Indexed: 09/29/2023] Open
Abstract
BACKGROUND Seed implant brachytherapy (SIBT) is an effective treatment modality for head and neck (H&N) cancers; however, current clinical planning requires manual setting of needle paths and utilizes inaccurate dose calculation algorithms. PURPOSE This study aims to develop an accurate and efficient deep convolutional neural network dose engine (DCNN-DE) and an automatic SIBT planning method for H&N SIBT. METHODS A cohort of 25 H&N patients who received SIBT was utilized to develop and validate the methods. The DCNN-DE was developed based on 3D-unet model. It takes single seed dose distribution from a modified TG-43 method, the CT image and a novel inter-seed shadow map (ISSM) as inputs, and predicts the dose map of accuracy close to the one from Monte Carlo simulations (MCS). The ISSM was proposed to better handle inter-seed attenuation. The accuracy and efficacy of the DCNN-DE were validated by comparing with other methods taking MCS dose as reference. For SIBT planning, a novel strategy inspired by clinical practice was proposed to automatically generate parallel or non-parallel potential needle paths that avoid puncturing bone and critical organs. A heuristic-based optimization method was developed to optimize the seed positions to meet clinical prescription requirements. The proposed planning method was validated by re-planning the 25 cases and comparing with clinical plans. RESULTS The absolute percentage error in the TG-43 calculation for CTV V100 and D90 was reduced from 5.4% and 13.2% to 0.4% and 1.1% with DCNN-DE, an accuracy improvement of 93% and 92%, respectively. The proposed planning method could automatically obtain a plan in 2.5 ± 1.5 min. The generated plans were judged clinically acceptable with dose distribution comparable with those of the clinical plans. CONCLUSIONS The proposed method can generate clinically acceptable plans quickly with high accuracy in dose evaluation, and thus has a high potential for clinical use in SIBT.
Collapse
Affiliation(s)
- Zhuo Xiao
- Image Processing Center, Beihang University, Beijing, People's Republic of China
| | - Tianyu Xiong
- School of Physics, Beihang University, Beijing, People's Republic of China
| | - Lishen Geng
- School of Physics, Beihang University, Beijing, People's Republic of China
| | - Fugen Zhou
- Image Processing Center, Beihang University, Beijing, People's Republic of China
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
| | - Bo Liu
- Image Processing Center, Beihang University, Beijing, People's Republic of China
- Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
| | - Haitao Sun
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, People's Republic of China
| | - Zhe Ji
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, People's Republic of China
| | - Yuliang Jiang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, People's Republic of China
| | - Junjie Wang
- Department of Radiation Oncology, Peking University Third Hospital, Beijing, People's Republic of China
| | - Qiuwen Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
3
|
Joya M, Nedaie HA, Geraily G, Rezaei H, Bromand A, Ghorbani M, Sheikhzadeh P. Investigation of TG-43 Dosimetric Parameters for 192Ir Brachytherapy Source Using GATE Monte Carlo Code. J Med Phys 2023; 48:268-273. [PMID: 37969149 PMCID: PMC10642593 DOI: 10.4103/jmp.jmp_41_23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 05/29/2023] [Accepted: 06/21/2023] [Indexed: 11/17/2023] Open
Abstract
Purpose According to the revised Task Group number 43 recommendations, a brachytherapy source must be validated against a similar or identical source before its clinical application. The purpose of this investigation is to verify the dosimetric data of the high dose rate (HDR) BEBIG 192Ir source (Ir2.A85-2). Materials and Methods The HDR 192Ir encapsulated seed was simulated and its main dosimetric data were calculated using Geant4 Application for Tomographic Emission (GATE) simulation code. Cubic cells were used for the calculation of dose rate constant and radial dose function while for anisotropy function ring cells were used. DoseActors were simulated and attached to the respective cells to obtain the required data. Results The dose rate constant was obtained as 1.098 ± 0.003 cGy.h - 1.U - 1, differing by 1.0% from the reference value reported by Granero et al. Similarly, the calculated values for radial dose and anisotropy functions presented good agreement with the results obtained by Granero et al. Conclusion The results of this study suggest that the GATE Monte Carlo code is a valid toolkit for benchmarking brachytherapy sources and can be used for brachytherapy simulation-based studies and verification of brachytherapy treatment planning systems.
Collapse
Affiliation(s)
- Musa Joya
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran, Iran
- Department of Radiology, Kabul University of Medical Sciences, Kabul, Afghanistan
| | - Hassan Ali Nedaie
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran, Iran
| | - Ghazale Geraily
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran, Iran
| | - Hadi Rezaei
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran, Iran
- Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| | - Awaz Bromand
- Department of Physics, Ghor Institute of Higher Education, Ghor, Afghanistan
| | - Mahdi Ghorbani
- Department of Biomedical Engineering and Medical Physics, School of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Peyman Sheikhzadeh
- Department of Medical Physics and Biomedical Engineering, Faculty of Medicine, Tehran, Iran
- Department of Nuclear Medicine, Imam Khomeini Hospital Complex, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Attalla EM, Sinousy DM, Ibrahim HF, Elmekawy AF, Elhussiny FA. The accuracy of out of field dose calculations in commercial treatment planning system using GATE/GEANT4 Monte Carlo simulation. Radiat Phys Chem Oxf Engl 1993 2023. [DOI: 10.1016/j.radphyschem.2023.110772] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
|
5
|
Te Ruruku T, Wong F, Marsh S. Accuracy of Acuros[Formula: see text] BV as determined from GATE monte-carlo simulation. Phys Eng Sci Med 2022; 45:1241-1249. [PMID: 36301444 DOI: 10.1007/s13246-022-01190-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 10/18/2022] [Indexed: 12/15/2022]
Abstract
The American Association of Physicists in Medicine's Task Group No.43 has provided a standardised dose calculation methodology that is now the international benchmark for all brachytherapy dosimetry publications and treatment planning systems. However, limitations in this methodology has seen the development of Model-Based Dose Calculation Algorithms (MBDCA). In 2009, Varian (Varian Medical Systems, Palo Alto, CA, USA) released Acuros[Formula: see text] BrachyVision (ABV) which calculates dose by explicitly solving the Linear Boltzmann Transport Equation. In this study we have assessed the accuracy of ABV dose calculations within a range of materials relevant to high dose rate brachytherapy with an iridium-192 ([Formula: see text]Ir) source. Accuracy assessment has been achieved by implementing a modelled GamaMed Plus [Formula: see text]Ir source within a series of phantoms using the GEANT4 Application for Emission Tomography (GATE) to calculate dose for comparison with dose as determined by ABV. Comparisons between GATE and ABV were made using point-to-point profile comparisons and 1D gamma analysis. Source validation results yielded good agreement with published data. Spectrum and TG43U1 comparisons showed no major differences, with TG43U1 comparisons agreeing within ± 1%. Point-to-point comparisons showed large differences between GATE and ABV near the source and in low density materials. 1D gamma analysis pass criteria of 2%/1 mm and 2%/2 mm yielded passing rates ranging between 51.72-100% and 62.07-100% respectively. A critical analysis of this study's results suggest that ABV is unable to accurately calculate doses in low density materials. Furthermore, spatial accuracy of dose near the source is within 2 mm.
Collapse
Affiliation(s)
- Tyrone Te Ruruku
- Medical Physics, Waikato Regional Cancer Center, Hamilton, Waikato, New Zealand.
| | - Felix Wong
- Medical Physics, Waikato Regional Cancer Center, Hamilton, Waikato, New Zealand
| | - Steven Marsh
- Medical Physics, University of Canterbury, Christchurch, Canterbury, New Zealand
| |
Collapse
|
6
|
Ait-Mlouk L, Khalis M, Asnaoui H, Ouabi H, Elboukhari S. Investigation of the dosimetric parameters of 125I BEBIG IsoSeed® I25.S06 source: GATE 8.2 Monte Carlo code. Appl Radiat Isot 2022; 186:110294. [DOI: 10.1016/j.apradiso.2022.110294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 04/17/2022] [Accepted: 05/13/2022] [Indexed: 11/02/2022]
|
7
|
BEBIG 60Co HDR brachytherapy source dosimetric parameters validation using GATE Geant4-based simulation code. Heliyon 2022; 8:e09168. [PMID: 35368537 PMCID: PMC8971593 DOI: 10.1016/j.heliyon.2022.e09168] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Revised: 01/20/2022] [Accepted: 03/07/2022] [Indexed: 11/21/2022] Open
Abstract
Purpose This study aims to validate the dosimetric characteristics of High Dose Rate (HDR) 60Co source (Co0.A86 model) using GATE Geant4-based Monte Carlo code. According to the recommendation of the American Association of Physicists in Medicine (AAPM) task group report number 43, the dosimetric parameters of a new brachytherapy source should be verified either experimentally or by Monte Carlo calculation before clinical applications. The validated 60Co source in this study will be used for the simulation of intensity-modulated brachytherapy (IMBT) of vaginal cancer using the same GATE Geant4-based Monte Carlo code in the future. Materials and methods GATE (version 9.0) simulation code was used to model and calculate the required TG-43U1 dosimetric data of the 60Co HDR source. DoseActors were defined for calculation of dose rate constant, radial dose function, and anisotropy function in a water phantom with an 80 cm radius. Results The dose rate constant was obtained as 1.070±0.008cGy.h−1.U−1 which shows a relative difference of 2.01% compared to the consensus value, 1.092 cGy.h−1.U−1. The calculated results of anisotropy and radial dose functions starting from 0.1 cm to 10 cm around the source showed excellent agreement with the results of published studies. The mean variation of the radial dose and anisotropy functions values from the consensus data were 1% and 0.9% respectively. Conclusion Findings from this investigation revealed that the validation of the HDR 60Co source is feasible by the GATE Geant4-based Monte Carlo code. As a result, the GATE Monte Carlo code can be used for the verification of the brachytherapy treatment planning system.
Collapse
|
8
|
Liu B, Xiong T, Lu J, Li S, Bai X, Zhou F, Wu Q. Technical note: A fast and accurate analytical dose calculation algorithm for 125 I seed-loaded stent applications. Med Phys 2021; 48:7493-7503. [PMID: 34482556 DOI: 10.1002/mp.15207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 08/12/2021] [Accepted: 08/28/2021] [Indexed: 12/09/2022] Open
Abstract
PURPOSE The safety and clinical efficacy of 125 I seed-loaded stent for the treatment of portal vein tumor thrombosis (PVTT) have been shown. Accurate and fast dose calculation of the 125 I seeds with the presence of the stent is necessary for the plan optimization and evaluation. However, the dosimetric characteristics of the seed-loaded stents remain unclear and there is no fast dose calculation technique available. This paper aims to explore a fast and accurate analytical dose calculation method based on Monte Carlo (MC) dose calculation, which takes into account the effect of stent and tissue inhomogeneity. METHODS A detailed model of the seed-loaded stent was developed using 3D modeling software and subsequently used in MC simulations to calculate the dose distribution around the stent. The dose perturbation caused by the presence of the stent was analyzed, and dose perturbation kernels (DPKs) were derived and stored for future use. Then, the dose calculation method from AAPM TG-43 was adapted by integrating the DPK and appropriate inhomogeneity correction factors (ICF) to calculate dose distributions analytically. To validate the proposed method, several comparisons were performed with other methods in water phantom and voxelized CT phantoms for three patients. RESULTS The stent has a considerable dosimetric effect reducing the dose up to 47.2% for single-seed stent and 11.9%-16.1% for 16-seed stent. In a water phantom, dose distributions from MC simulations and TG-43-DP-ICF showed a good agreement with the relative error less than 3.3%. In voxelized CT phantoms, taking MC results as the reference, the relative errors of TG-43 method can be up to 33%, while those of TG-43-DP-ICF method were less than 5%. For a dose matrix with 256 × 256 × 46 grid (corresponding to a phantom of 17.2 × 17.2 × 11.5 cm3 ) for 16-seed-loaded stent, it only takes 17 s for TG-43-DP-ICF to compute, compared to 25 h for the full MC calculation. CONCLUSIONS The combination of DPK and inhomogeneity corrections is an effective approach to handle both the presence of stent and tissue heterogeneity. Exhibiting good agreement with MC calculation and computational efficiency, the proposed TG-43-DP-ICF method is adequate for dose evaluation and optimization in seed-loaded stent implantation treatment planning.
Collapse
Affiliation(s)
- Bo Liu
- Image Processing Center, Beihang University, Beijing, People's Republic of China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
| | - Tianyu Xiong
- Department of Physics, Beihang University, Beijing, People's Republic of China
| | - Jian Lu
- Center of Interventional Radiology & Vascular Surgery, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China
| | - Shengwei Li
- Center of Interventional Radiology & Vascular Surgery, Department of Radiology, Zhongda Hospital, Medical School, Southeast University, Nanjing, China
| | - Xiangzhi Bai
- Image Processing Center, Beihang University, Beijing, People's Republic of China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
| | - Fugen Zhou
- Image Processing Center, Beihang University, Beijing, People's Republic of China.,Beijing Advanced Innovation Center for Biomedical Engineering, Beihang University, Beijing, People's Republic of China
| | - Qiuwen Wu
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina, USA
| |
Collapse
|
9
|
Kim SB, Song IH, Song YS, Lee BC, Gupta A, Lee JS, Park HS, Kim SE. Biodistribution and internal radiation dosimetry of a companion diagnostic radiopharmaceutical, [ 68Ga]PSMA-11, in subcutaneous prostate cancer xenograft model mice. Sci Rep 2021; 11:15263. [PMID: 34315965 PMCID: PMC8316415 DOI: 10.1038/s41598-021-94684-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/15/2021] [Indexed: 11/09/2022] Open
Abstract
[68Ga]PSMA-11 is a prostate-specific membrane antigen (PSMA)-targeting radiopharmaceutical for diagnostic PET imaging. Its application can be extended to targeted radionuclide therapy (TRT). In this study, we characterize the biodistribution and pharmacokinetics of [68Ga]PSMA-11 in PSMA-positive and negative (22Rv1 and PC3, respectively) tumor-bearing mice and subsequently estimated its internal radiation dosimetry via voxel-level dosimetry using a dedicated Monte Carlo simulation to evaluate the absorbed dose in the tumor directly. Consequently, this approach overcomes the drawbacks of the conventional organ-level (or phantom-based) method. The kidneys and urinary bladder both showed substantial accumulation of [68Ga]PSMA-11 without exhibiting a washout phase during the study. For the tumor, a peak concentration of 4.5 ± 0.7 %ID/g occurred 90 min after [68Ga]PSMA-11 injection. The voxel- and organ-level methods both determined that the highest absorbed dose occurred in the kidneys (0.209 ± 0.005 Gy/MBq and 0.492 ± 0.059 Gy/MBq, respectively). Using voxel-level dosimetry, the absorbed dose in the tumor was estimated as 0.024 ± 0.003 Gy/MBq. The biodistribution and pharmacokinetics of [68Ga]PSMA-11 in various organs of subcutaneous prostate cancer xenograft model mice were consistent with reported data for prostate cancer patients. Therefore, our data supports the use of voxel-level dosimetry in TRT to deliver personalized dosimetry considering patient-specific heterogeneous tissue compositions and activity distributions.
Collapse
Affiliation(s)
- Su Bin Kim
- Department of Applied Bioengineering, Graduate School of Convergence Science and Technology, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Korea.,Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea
| | - In Ho Song
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea
| | - Yoo Sung Song
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea
| | - Byung Chul Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea
| | - Arun Gupta
- Department of Radiology and Imaging Institution: B.P. Koirala Institute of Health Sciences (BPKIHS), Dharan-18, Province-1, Sunsari, Nepal
| | - Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03080, Korea
| | - Hyun Soo Park
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea.
| | - Sang Eun Kim
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul National University Bundang Hospital, 82 Gumi-ro, 173 Beon-gil, Bundang-gu, Seongnam, 13620, Korea. .,Advanced Institutes of Convergence Technology, 145 Gwanggyo-ro, Yeongtong-gu, Suwon, 16229, Korea. .,Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul National University, 1 Gwanak-ro, Gwanak-gu, Seoul, 08826, Korea.
| |
Collapse
|
10
|
Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy. Nucl Med Mol Imaging 2021; 55:86-95. [PMID: 33968275 DOI: 10.1007/s13139-020-00680-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/28/2020] [Accepted: 12/21/2020] [Indexed: 10/22/2022] Open
Abstract
Purpose Dose distributions are calculated by Monte Carlo (MC) simulations for two low-energy models 125I brachytherapy source-IrSeed-125 and IsoAid Advantage (model IAI-125A)-loaded in the 14-mm standardized plaque of the COMS during treatment of choroid melanoma. Methods In this study, at first, the radial dose function in water around 125I brachytherapy sources was calculated based on the recommendations of the Task Group No. 43 American Association of Physicists in Medicine (TG-43U1 APPM) using by GATE code. Then, brachytherapy dose distribution of a new model of the human eye was investigated for a 14-mm COMS eye plaque loaded with these sources with GATE Monte Carlo simulation. Results Results show that there are good agreements between simulation results of these sources and reporting measurements and simulations. Dosimetry results in the designed eye phantom for two types of iodine seeds show that the ratios of average dose of tumor to sclera, vitreous, and retina for IrSeed (IsoAid) source are 3.7 (3.7), 6.2 (6.1), and 6.3 (6.3), respectively, which represents the dose saving to healthy tissues. The maximum percentage differences between DVH curve of IsoAid and IrSeed seeds was about 8%. Conclusions Our simulation results show that although new model of the 125I brachytherapy source having a slightly larger dimension than IAI-125A, it can be used for eye melanoma treatment because the COMS eye plaque loaded with IrSeed-125 could produce similar results to the IsoAid seeds, which is applicable for clinical plaque brachytherapy for uveal melanoma.
Collapse
|
11
|
Tang W, Tang B, Li X, Wang Y, Li Z, Gao Y, Gao H, Yan C, Sun L. Cellular S-value evaluation based on real human cell models using the GATE MC package. Appl Radiat Isot 2020; 168:109509. [PMID: 33214023 DOI: 10.1016/j.apradiso.2020.109509] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2020] [Revised: 10/28/2020] [Accepted: 11/06/2020] [Indexed: 11/25/2022]
Abstract
Exploring the spatial distribution of the energy loss of ionising radiation at the subcellular level is indispensable for evaluating the radiobiological effects of targeted radionuclide therapy accurately. Believing that S-values are important for obtaining the target dose, the Committee on Medical Internal Radiation Dose (MIRD) proposed a method to obtain the cellular dosimetric parameter. However, most available data on cellular S-values were calculated based on simple geometric models, such as ellipsoids or spheres, which do not accurately reflect biological reality. To investigate the influence of the cellular model on S-values, calculations were performed for two kinds of polygon-surface phantom models of realistic, individual human cells, the lung epithelial cell model (the B2B Phantom model) and the hepatocyte model (the Liver Phantom model), using the Monte Carlo (MC) software package GATE. To analyse the influence of cell geometry on the final S-value, the differences in the S-values between the realistic cell models and simple geometric sphere and ellipsoid models with similar volumes were calculated and compared for six different combinations of source and target regions. The irradiation conditions were 0.01-1.10 MeV monoenergetic electron sources and the Auger electronic therapy nuclides Ga-67, Tc-99m, In-111, I-125 and Tl-201, which are commonly used in nuclear medicine. The S-values calculated in this study are different from the results of the simple geometry models proposed by previous researchers. Two more precise polygon-surface phantom models of realistic, individual human cells were used, which provided more accurate information about the cell dose and will be very useful for the diagnostic application of radiotherapy in the future.
Collapse
Affiliation(s)
- Wei Tang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Bo Tang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China; Department of Radiation Protection Safety, Shandong Center for Disease Control and Prevention, Jinan, 250014, China
| | - Xiang Li
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Yidi Wang
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Zhanpeng Li
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Yunan Gao
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Han Gao
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Congchong Yan
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China
| | - Liang Sun
- State Key Laboratory of Radiation Medicine and Protection, School of Radiation Medicine and Protection, Soochow University, Suzhou, 215123, China; Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, China.
| |
Collapse
|
12
|
Abolaban FA, Taha EM. Representation and illustration of the initial parameters in GATE 8.1 monte carlo simulation of an Elekta Versa-HD linear accelerator. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES 2020. [DOI: 10.1080/16878507.2020.1820271] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Affiliation(s)
- Fouad A. Abolaban
- King Abdulaziz University, College of Engineering, Nuclear Engineering Department, Jeddah, Kingdom of Saudi Arabia, Jeddah, Saudi Arabia
| | - Eslam M. Taha
- King Abdulaziz University, College of Engineering, Nuclear Engineering Department, Jeddah, Kingdom of Saudi Arabia, Jeddah, Saudi Arabia
| |
Collapse
|
13
|
Tiwari A, Gravesa SA, Sunderland J. The Impact of Tissue Type and Density on Dose Point Kernels for Patient-Specific Voxel-Wise Dosimetry: A Monte Carlo Investigation. Radiat Res 2020; 193:531-542. [PMID: 32315249 DOI: 10.1667/rr15563.1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2019] [Accepted: 03/11/2020] [Indexed: 11/03/2022]
Abstract
We report the generation of dose point kernels for clinically-relevant radionuclide beta decays and monoenergetic electrons in various tissues to understand the impact of tissue type on dose point kernels. Currently available voxel-wise dosimetry approaches using dose point kernels ignore tissue composition and density heterogeneities. Therefore, the study on the impact of tissue type on dose point kernels is warranted. Simulations were performed using the GATE Monte Carlo toolkit, which encapsulates GEANT4 libraries. Dose point kernels were simulated in phantoms of water, compact bone, lung, adipose tissue, blood and red marrow for radionuclides 90Y, 188Re, 32P, 89Sr, 186Re, 153Sm and 177Lu and monoenergetic electrons (0.015-10 MeV). All simulations were performed by assuming an isotropic point source of electrons at the center of a homogeneous spherical phantom. Tissue-specific differences between kernels were investigated by normalizing kernels for effective pathlength. Transport of 20 million particles was found to provide sufficient statistical precision in all simulated kernels. The simulated dose point kernels demonstrate excellent agreement with other Monte Carlo packages. Deviation from kernels reported in the literature did not exceed a 10% global difference, which is consistent with the variability among published results. There are no significant differences between the dose point kernel in water and kernels in other tissues that have been scaled to account for density; however, tissue density predictably demonstrated itself to be a significant variable in dose point kernel distribution.
Collapse
Affiliation(s)
- Ashok Tiwari
- Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242.,Department of Physics, University of Iowa, Iowa City, Iowa 52242
| | - Stephen A Gravesa
- Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242
| | - John Sunderland
- Department of Radiology, University of Iowa Hospitals and Clinics, Iowa City, Iowa 52242.,Department of Physics, University of Iowa, Iowa City, Iowa 52242
| |
Collapse
|
14
|
Dipuglia A, Cameron M, Davis JA, Cornelius IM, Stevenson AW, Rosenfeld AB, Petasecca M, Corde S, Guatelli S, Lerch MLF. Validation of a Monte Carlo simulation for Microbeam Radiation Therapy on the Imaging and Medical Beamline at the Australian Synchrotron. Sci Rep 2019; 9:17696. [PMID: 31776395 PMCID: PMC6881291 DOI: 10.1038/s41598-019-53991-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2019] [Accepted: 11/05/2019] [Indexed: 01/05/2023] Open
Abstract
Microbeam Radiation Therapy (MRT) is an emerging cancer treatment modality characterised by the use of high-intensity synchrotron-generated x-rays, spatially fractionated by a multi-slit collimator (MSC), to ablate target tumours. The implementation of an accurate treatment planning system, coupled with simulation tools that allow for independent verification of calculated dose distributions are required to ensure optimal treatment outcomes via reliable dose delivery. In this article we present data from the first Geant4 Monte Carlo radiation transport model of the Imaging and Medical Beamline at the Australian Synchrotron. We have developed the model for use as an independent verification tool for experiments in one of three MRT delivery rooms and therefore compare simulation results with equivalent experimental data. The normalised x-ray spectra produced by the Geant4 model and a previously validated analytical model, SPEC, showed very good agreement using wiggler magnetic field strengths of 2 and 3 T. However, the validity of absolute photon flux at the plane of the Phase Space File (PSF) for a fixed number of simulated electrons was unable to be established. This work shows a possible limitation of the G4SynchrotronRadiation process to model synchrotron radiation when using a variable magnetic field. To account for this limitation, experimentally derived normalisation factors for each wiggler field strength determined under reference conditions were implemented. Experimentally measured broadbeam and microbeam dose distributions within a Gammex RMI457 Solid Water® phantom were compared to simulated distributions generated by the Geant4 model. Simulated and measured broadbeam dose distributions agreed within 3% for all investigated configurations and measured depths. Agreement between the simulated and measured microbeam dose distributions agreed within 5% for all investigated configurations and measured depths.
Collapse
Affiliation(s)
- Andrew Dipuglia
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Matthew Cameron
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Jeremy A Davis
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Iwan M Cornelius
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Andrew W Stevenson
- CSIRO, Clayton, 3168, Australia
- Imaging and Medical Beamline, ANSTO/Australian Synchrotron, Melbourne, 3168, Australia
| | - Anatoly B Rosenfeld
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Marco Petasecca
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Stéphanie Corde
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
- Department of Radiation Oncology, Prince of Wales Hospital, Randwick, 2031, Australia
| | - Susanna Guatelli
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia
| | - Michael L F Lerch
- Centre for Medical and Radiation Physics, University of Wollongong, Wollongong, 2522, Australia.
| |
Collapse
|
15
|
Sarrut D, Krah N, Létang JM. Generative adversarial networks (GAN) for compact beam source modelling in Monte Carlo simulations. ACTA ACUST UNITED AC 2019; 64:215004. [DOI: 10.1088/1361-6560/ab3fc1] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
16
|
A comparison between GATE and MCNPX for photon dose calculations in radiation protection using a male voxel phantom. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2018.12.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
17
|
A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2019. [DOI: 10.2478/pjmpe-2019-0003] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Permanent and temporary implantation of I-125 brachytherapy sources has become an official method for the treatment of different cancers. In this technique, it is essential to determine dose distribution around the brachytherapy source to choose the optimal treatment plan. In this study, the dosimetric parameters for a new interstitial brachytherapy source I-125 (IrSeed-125) were calculated with GATE/GEANT4 Monte Carlo code. Dose rate constant, radial dose function and 2D anisotropy function were calculated inside a water phantom (based on the recommendations of TG-43U1 protocol), and inside several tissue phantoms around the IrSeed-125 capsule. Acquired results were compared with MCNP simulation and experimental data. The dose rate constant of IrSeed-125 in the water phantom was about 1.038 cGy·h−1U−1 that shows good consistency with the experimental data. The radial dose function at 0.5, 0.9, 1.8, 3 and 7 cm radial distances were obtained as 1.095, 1.019, 0.826, 0.605, and 0.188, respectively. The results of the IrSeed-125 is not only in good agreement with those calculated by other simulation with MCNP code but also are closer to the experimental results. Discrepancies in the estimation of dose around IrSeed-125 capsule in the muscle and fat tissue phantoms are greater than the breast and lung phantoms in comparison with the water phantom. Results show that GATE/GEANT4 Monte Carlo code produces accurate results for dosimetric parameters of the IrSeed-125 LDR brachytherapy source with choosing the appropriate physics list. There are some differences in the dose calculation in the tissue phantoms in comparison with water phantom, especially in long distances from the source center, which may cause errors in the estimation of dose around brachytherapy sources that are not taken account by the TG43-U1 formalism.
Collapse
|
18
|
Seo J, Son J, Cho Y, Park N, Kim DW, Kim J, Yoon M. Kilovoltage radiotherapy for companion animals: dosimetric comparison of 300 kV, 450 kV, and 6 MV X-ray beams. J Vet Sci 2018; 19:550-556. [PMID: 29649856 PMCID: PMC6070583 DOI: 10.4142/jvs.2018.19.4.550] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Revised: 03/21/2018] [Accepted: 03/31/2018] [Indexed: 11/20/2022] Open
Abstract
Radiotherapy for the treatment of cancer in companion animals is currently administered by using megavoltage X-ray machines. Because these machines are expensive, most animal hospitals do not perform radiotherapy. This study evaluated the ability of relatively inexpensive kilovoltage X-ray machines to treat companion animals. A simulation study based on a commercial treatment-planning system was performed for tumors of the brain (non-infectious meningoencephalitis), nasal cavity (malignant nasal tumors), forefoot (malignant muscular tumors), and abdomen (malignant intestinal tumors). The results of kilovoltage (300 kV and 450 kV) and megavoltage (6 MV) X-ray beams were compared. Whereas the 300 kV and 6 MV X-ray beams provided optimal radiation dose homogeneity and conformity, respectively, for brain tumors, the 6 MV X-rays provided optimal homogeneity and radiation conformity for nasal cavity, forefoot, and abdominal tumors. Although megavoltage X-ray beams provided better radiation dose distribution in most treated animals, the differences between megavoltage and kilovoltage X-ray beams were relatively small. The similar therapeutic effects of the kilovoltage and 6 MV X-ray beams suggest that kilovoltage X-ray beams may be effective alternatives to megavoltage X-ray beams in treating cancers in companion animals.
Collapse
Affiliation(s)
- Jaehyeon Seo
- Department of Bio-Convergence Engineering, Korea University, Seoul 02841, Korea
| | - Jaeman Son
- Department of Bio-Convergence Engineering, Korea University, Seoul 02841, Korea
| | - Yeona Cho
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Nohwon Park
- Korea Animal Cancer Center, Seoul 01684, Korea
| | - Dong Wook Kim
- Department of Radiation Oncology, Kyung Hee University Hospital at Gangdong, Seoul 05278, Korea
| | - Jinsung Kim
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul 03722, Korea
| | - Myonggeun Yoon
- Department of Bio-Convergence Engineering, Korea University, Seoul 02841, Korea
| |
Collapse
|
19
|
Ou H, Zhang B, Zhao S. Monte Carlo simulation of the relative biological effectiveness and DNA damage from a 400 MeV/u carbon ion beam in water. Appl Radiat Isot 2018; 136:1-9. [DOI: 10.1016/j.apradiso.2018.01.038] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2017] [Revised: 01/26/2018] [Accepted: 01/26/2018] [Indexed: 11/25/2022]
|
20
|
Besemer AE, Yang YM, Grudzinski JJ, Hall LT, Bednarz BP. Development and Validation of RAPID: A Patient-Specific Monte Carlo Three-Dimensional Internal Dosimetry Platform. Cancer Biother Radiopharm 2018; 33:155-165. [PMID: 29694246 DOI: 10.1089/cbr.2018.2451] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
This work describes the development and validation of a patient-specific Monte Carlo internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID utilizes serial PET/CT or SPECT/CT images to calculate voxelized three-dimensional (3D) internal dose distributions with the Monte Carlo code Geant4. RAPID's dosimetry calculations were benchmarked against previously published S-values and specific absorbed fractions (SAFs) calculated for monoenergetic photon and electron sources within the Zubal phantom and for S-values calculated for a variety of radionuclides within spherical tumor phantoms with sizes ranging from 1 to 1000 g. The majority of the S-values and SAFs calculated in the Zubal Phantom were within 5% of the previously published values with the exception of a few 10 keV photon SAFs that agreed within 10%, and one value within 16%. The S-values calculated in the spherical tumor phantoms agreed within 2% for 177Lu, 131I, 125I, 18F, and 64Cu, within 3.5% for 211At and 213Bi, within 6.5% for 153Sm, 111In, 89Zr, and 223Ra, and within 9% for 90Y, 68Ga, and 124I. In conclusion, RAPID is capable of calculating accurate internal dosimetry at the voxel-level for a wide variety of radionuclides and could be a useful tool for calculating patient-specific 3D dose distributions.
Collapse
Affiliation(s)
- Abigail E Besemer
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin.,2 Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin , Madison, Wisconsin
| | - You Ming Yang
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin.,3 Department of Radiation Oncology, University of California - Los Angeles , Los Angeles, California
| | - Joseph J Grudzinski
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin
| | - Lance T Hall
- 4 Department of Radiology, School of Medicine and Public Health, University of Wisconsin , Madison, Wisconsin.,5 Carbone Cancer Center, University of Wisconsin-Madison , Madison, Wisconsin
| | - Bryan P Bednarz
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin
| |
Collapse
|
21
|
Papadimitroulas P. Dosimetry applications in GATE Monte Carlo toolkit. Phys Med 2017; 41:136-140. [DOI: 10.1016/j.ejmp.2017.02.005] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Revised: 02/08/2017] [Accepted: 02/10/2017] [Indexed: 10/20/2022] Open
|
22
|
Fallahpoor M, Abbasi M, Kalantari F, Parach AA, Sen A. Practical Nuclear Medicine and Utility of Phantoms for Internal Dosimetry: XCAT Compared with Zubal. RADIATION PROTECTION DOSIMETRY 2017; 174:191-197. [PMID: 27247443 DOI: 10.1093/rpd/ncw115] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2016] [Accepted: 04/13/2016] [Indexed: 06/05/2023]
Abstract
PURPOSE The absorbed doses for two radioisotopes, 99mTc and 131I, between previously validated Zubal phantom and the recently developed XCAT phantom were compared. MATERIALS AND METHODS GATE Monte Carlo code was used to simulate the statistical process of radiation. A XCAT phantom with voxel and matrix sizes similar to a standard Zubal phantom was generated. According to Medical International Radiation Dose formalism, specific absorbed fraction (SAF) values for photons and S-factors for beta particles were tabulated. The amounts of absorbed doses were calculated and compared in different organs. RESULTS The differences of gamma radiation doses, SAFs, between Zubal and XCAT are >50% in adrenal from adrenal, pancreas from pancreas and thyroid from thyroid, in lung from kidney, kidneys from lungs and in kidneys from thyroid and thyroid from kidneys. The beta radiation doses differences between Zubal and XCAT are >50% in thyroid from thyroid, bladder from bladder, kidney from kidney, liver from bladder, thyroid from bladder and kidney from thyroid. The size and distances of the organs were different between XCAT and Zubal phantoms. Denoted differences of SAF and S-factors correspond to the different organ geometries in phantoms. CONCLUSION The results of absorbed doses in Zubal and XCAT phantoms are different. The variations prohibit easy comparison or interchangeability of dosimetry between these phantoms.
Collapse
Affiliation(s)
- Maryam Fallahpoor
- Department of Nuclear Medicine, Vali-Asr Hospital, School of Medicine, Tehran University of Medical Sciences, Tehran 1419731351, Iran
| | - Mehrshad Abbasi
- Department of Nuclear Medicine, Vali-Asr Hospital, School of Medicine, Tehran University of Medical Sciences, Tehran 1419731351, Iran
| | - Faraz Kalantari
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, Texas 75235
| | - Ali Asghar Parach
- Department of Medical Physics, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Anando Sen
- Department of Biomedical Engineering, University of Houston, Houston, Texas 77004
| |
Collapse
|
23
|
Sommer H, Ebenau M, Spaan B, Eichmann M. Monte Carlo simulation of ruthenium eye plaques with GEANT4: influence of multiple scattering algorithms, the spectrum and the geometry on depth dose profiles. Phys Med Biol 2017; 62:1848-1864. [DOI: 10.1088/1361-6560/aa5696] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Bednarz B, Besemer A. Radiation-Induced Second Cancer Risk Estimates From Radionuclide Therapy. EPJ WEB OF CONFERENCES 2017. [DOI: 10.1051/epjconf/201715304020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|
25
|
Asl RG, Parach AA, Nasseri S, Momennezhad M, Zakavi SR, Sadoughi HR. Specific Absorbed Fractions of Internal Photon and Electron Emitters in a Human Voxel-based Phantom: A Monte Carlo Study. World J Nucl Med 2017; 16:114-121. [PMID: 28553177 PMCID: PMC5436316 DOI: 10.4103/1450-1147.203065] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
The specific absorbed fraction (SAF) of energy is an essential element of internal dose assessment. Here reported a set of SAFs calculated for selected organs of a human voxel-based phantom. The Monte Carlo transport code GATE version 6.1 was used to simulate monoenergetic photons and electrons with energies ranging from 10 keV to 2 MeV. The particles were emitted from three source organs: kidneys, liver, and spleen. SAFs were calculated for three target regions in the body (kidneys, liver, and spleen) and compared with the results obtained using the MCNP4B and GATE/GEANT4 Monte Carlo codes. For most photon energies, the self-irradiation is higher, and the cross-irradiation is lower in the GATE results compared to the MCNP4B. The results show generally good agreement for photons and high-energy electrons with discrepancies within − 2% ±3%. Nevertheless, significant differences were found for cross-irradiation of photons of lower energy and electrons of higher energy due to statistical uncertainties larger than 10%. The comparisons of the SAF values for the human voxel phantom do not show significant differences, and the results also demonstrated the usefulness and applicability of GATE Monte Carlo package for voxel level dose calculations in nonuniform media. The present SAFs calculation for the Zubal voxel phantom is validated by the intercomparison of the results obtained by other Monte Carlo codes.
Collapse
Affiliation(s)
- Ruhollah Ghahraman Asl
- Bioinformatics Research Centre, Department of Nutrition and Biochemistry, Faculty of Medicine, Sabzevar University of Medical Sciences, Sabzevar, Iran
| | - Ali Asghar Parach
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Shahrokh Nasseri
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Mehdi Momennezhad
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Seyed Rasoul Zakavi
- Nuclear Medicine Research Center, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamid Reza Sadoughi
- Department of Biotechnology and Molecular Sciences, Faculty of Medicine, North Khorasan University of Medical Sciences, Bojnurd, Iran
| |
Collapse
|
26
|
Didi S, Moussa A, Yahya T, Mustafa Z. Simulation of the 6 MV Elekta Synergy Platform linac photon beam using Geant4 Application for Tomographic Emission. J Med Phys 2015; 40:136-43. [PMID: 26500399 PMCID: PMC4594382 DOI: 10.4103/0971-6203.165077] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
The present work validates the Geant4 Application for Tomographic Emission Monte Carlo software for the simulation of a 6 MV photon beam given by Elekta Synergy Platform medical linear accelerator treatment head. The simulation includes the major components of the linear accelerator (LINAC) with multi-leaf collimator and a homogeneous water phantom. Calculations were performed for the photon beam with several treatment field sizes ranging from 5 cm × 5 cm to 30 cm × 30 cm at 100 cm distance from the source. The simulation was successfully validated by comparison with experimental distributions. Good agreement between simulations and measurements was observed, with dose differences of about 0.02% and 2.5% for depth doses and lateral dose profiles, respectively. This agreement was also emphasized by the Kolmogorov-Smirnov goodness-of-fit test and by the gamma-index comparisons where more than 99% of the points for all simulations fulfill the quality assurance criteria of 2 mm/2%.
Collapse
Affiliation(s)
- Samir Didi
- Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda 60000, Morocco ; Department of Physics, Regional Hassan II Oncology Center, Oujda 60000, Morocco
| | - Abdelilah Moussa
- Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda 60000, Morocco ; Department of Physics, National School of Applied sciences of Al-Hoceima, Morocco
| | - Tayalati Yahya
- Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda 60000, Morocco
| | - Zerfaoui Mustafa
- Department of Physics, Laboratory of Physics of Radiation and Matter, Faculty of Sciences, University Mohammed First, Oujda 60000, Morocco ; Department of Physics, Regional Hassan II Oncology Center, Oujda 60000, Morocco
| |
Collapse
|
27
|
Sarrut D, Bardiès M, Boussion N, Freud N, Jan S, Létang JM, Loudos G, Maigne L, Marcatili S, Mauxion T, Papadimitroulas P, Perrot Y, Pietrzyk U, Robert C, Schaart DR, Visvikis D, Buvat I. A review of the use and potential of the GATE Monte Carlo simulation code for radiation therapy and dosimetry applications. Med Phys 2015; 41:064301. [PMID: 24877844 DOI: 10.1118/1.4871617] [Citation(s) in RCA: 238] [Impact Index Per Article: 26.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
In this paper, the authors' review the applicability of the open-source GATE Monte Carlo simulation platform based on the GEANT4 toolkit for radiation therapy and dosimetry applications. The many applications of GATE for state-of-the-art radiotherapy simulations are described including external beam radiotherapy, brachytherapy, intraoperative radiotherapy, hadrontherapy, molecular radiotherapy, and in vivo dose monitoring. Investigations that have been performed using GEANT4 only are also mentioned to illustrate the potential of GATE. The very practical feature of GATE making it easy to model both a treatment and an imaging acquisition within the same framework is emphasized. The computational times associated with several applications are provided to illustrate the practical feasibility of the simulations using current computing facilities.
Collapse
Affiliation(s)
- David Sarrut
- Université de Lyon, CREATIS; CNRS UMR5220; Inserm U1044; INSA-Lyon; Université Lyon 1; Centre Léon Bérard, France
| | - Manuel Bardiès
- Inserm, UMR1037 CRCT, F-31000 Toulouse, France and Université Toulouse III-Paul Sabatier, UMR1037 CRCT, F-31000 Toulouse, France
| | | | - Nicolas Freud
- Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Centre Léon Bérard, 69008 Lyon, France
| | | | - Jean-Michel Létang
- Université de Lyon, CREATIS, CNRS UMR5220, Inserm U1044, INSA-Lyon, Université Lyon 1, Centre Léon Bérard, 69008 Lyon, France
| | - George Loudos
- Department of Medical Instruments Technology, Technological Educational Institute of Athens, Athens 12210, Greece
| | - Lydia Maigne
- UMR 6533 CNRS/IN2P3, Université Blaise Pascal, 63171 Aubière, France
| | - Sara Marcatili
- Inserm, UMR1037 CRCT, F-31000 Toulouse, France and Université Toulouse III-Paul Sabatier, UMR1037 CRCT, F-31000 Toulouse, France
| | - Thibault Mauxion
- Inserm, UMR1037 CRCT, F-31000 Toulouse, France and Université Toulouse III-Paul Sabatier, UMR1037 CRCT, F-31000 Toulouse, France
| | - Panagiotis Papadimitroulas
- Department of Biomedical Engineering, Technological Educational Institute of Athens, 12210, Athens, Greece
| | - Yann Perrot
- UMR 6533 CNRS/IN2P3, Université Blaise Pascal, 63171 Aubière, France
| | - Uwe Pietrzyk
- Institut für Neurowissenschaften und Medizin, Forschungszentrum Jülich GmbH, 52425 Jülich, Germany and Fachbereich für Mathematik und Naturwissenschaften, Bergische Universität Wuppertal, 42097 Wuppertal, Germany
| | - Charlotte Robert
- IMNC, UMR 8165 CNRS, Universités Paris 7 et Paris 11, Orsay 91406, France
| | - Dennis R Schaart
- Delft University of Technology, Faculty of Applied Sciences, Radiation Science and Technology Department, Delft Mekelweg 15, 2629 JB Delft, The Netherlands
| | | | - Irène Buvat
- IMNC, UMR 8165 CNRS, Universités Paris 7 et Paris 11, 91406 Orsay, France and CEA/DSV/I2BM/SHFJ, 91400 Orsay, France
| |
Collapse
|
28
|
Belley MD, Segars WP, Kapadia AJ. Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver. Med Phys 2014; 41:063902. [PMID: 24877842 PMCID: PMC4032437 DOI: 10.1118/1.4873684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2013] [Revised: 04/10/2014] [Accepted: 04/14/2014] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. METHODS Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm(3)). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. RESULTS The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ~15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ~75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. CONCLUSIONS Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.
Collapse
Affiliation(s)
- Matthew D Belley
- Medical Physics Graduate Program, Duke University, Durham 27705, North Carolina
| | - William Paul Segars
- Medical Physics Graduate Program, Duke University, Durham, North Carolina and Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham 27710, North Carolina
| | - Anuj J Kapadia
- Medical Physics Graduate Program, Duke University, Durham, North Carolina and Department of Radiology, Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham 27710, North Carolina
| |
Collapse
|
29
|
Cornelius I, Guatelli S, Fournier P, Crosbie JC, Sanchez Del Rio M, Bräuer-Krisch E, Rosenfeld A, Lerch M. Benchmarking and validation of a Geant4-SHADOW Monte Carlo simulation for dose calculations in microbeam radiation therapy. JOURNAL OF SYNCHROTRON RADIATION 2014; 21:518-528. [PMID: 24763641 DOI: 10.1107/s1600577514004640] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2013] [Accepted: 02/28/2014] [Indexed: 06/03/2023]
Abstract
Microbeam radiation therapy (MRT) is a synchrotron-based radiotherapy modality that uses high-intensity beams of spatially fractionated radiation to treat tumours. The rapid evolution of MRT towards clinical trials demands accurate treatment planning systems (TPS), as well as independent tools for the verification of TPS calculated dose distributions in order to ensure patient safety and treatment efficacy. Monte Carlo computer simulation represents the most accurate method of dose calculation in patient geometries and is best suited for the purpose of TPS verification. A Monte Carlo model of the ID17 biomedical beamline at the European Synchrotron Radiation Facility has been developed, including recent modifications, using the Geant4 Monte Carlo toolkit interfaced with the SHADOW X-ray optics and ray-tracing libraries. The code was benchmarked by simulating dose profiles in water-equivalent phantoms subject to irradiation by broad-beam (without spatial fractionation) and microbeam (with spatial fractionation) fields, and comparing against those calculated with a previous model of the beamline developed using the PENELOPE code. Validation against additional experimental dose profiles in water-equivalent phantoms subject to broad-beam irradiation was also performed. Good agreement between codes was observed, with the exception of out-of-field doses and toward the field edge for larger field sizes. Microbeam results showed good agreement between both codes and experimental results within uncertainties. Results of the experimental validation showed agreement for different beamline configurations. The asymmetry in the out-of-field dose profiles due to polarization effects was also investigated, yielding important information for the treatment planning process in MRT. This work represents an important step in the development of a Monte Carlo-based independent verification tool for treatment planning in MRT.
Collapse
Affiliation(s)
- Iwan Cornelius
- Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia
| | - Susanna Guatelli
- Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia
| | - Pauline Fournier
- Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia
| | - Jeffrey C Crosbie
- Department of Obstetrics and Gynaecology, The University of Melbourne, Parkville, Victoria 3152, Australia
| | | | | | - Anatoly Rosenfeld
- Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia
| | - Michael Lerch
- Centre for Medical Radiation Physics, University of Wollongong, New South Wales 2522, Australia
| |
Collapse
|
30
|
Belley MD, Wang C, Nguyen G, Gunasingha R, Chao NJ, Chen BJ, Dewhirst MW, Yoshizumi TT. Toward an organ based dose prescription method for the improved accuracy of murine dose in orthovoltage x-ray irradiators. Med Phys 2014; 41:034101. [PMID: 24593746 PMCID: PMC3987731 DOI: 10.1118/1.4864237] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 12/16/2013] [Accepted: 01/16/2014] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Accurate dosimetry is essential when irradiating mice to ensure that functional and molecular endpoints are well understood for the radiation dose delivered. Conventional methods of prescribing dose in mice involve the use of a single dose rate measurement and assume a uniform average dose throughout all organs of the entire mouse. Here, the authors report the individual average organ dose values for the irradiation of a 12, 23, and 33 g mouse on a 320 kVp x-ray irradiator and calculate the resulting error from using conventional dose prescription methods. METHODS Organ doses were simulated in the Geant4 application for tomographic emission toolkit using the MOBY mouse whole-body phantom. Dosimetry was performed for three beams utilizing filters A (1.65 mm Al), B (2.0 mm Al), and C (0.1 mm Cu + 2.5 mm Al), respectively. In addition, simulated x-ray spectra were validated with physical half-value layer measurements. RESULTS Average doses in soft-tissue organs were found to vary by as much as 23%-32% depending on the filter. Compared to filters A and B, filter C provided the hardest beam and had the lowest variation in soft-tissue average organ doses across all mouse sizes, with a difference of 23% for the median mouse size of 23 g. CONCLUSIONS This work suggests a new dose prescription method in small animal dosimetry: it presents a departure from the conventional approach of assigninga single dose value for irradiation of mice to a more comprehensive approach of characterizing individual organ doses to minimize the error and uncertainty. In human radiation therapy, clinical treatment planning establishes the target dose as well as the dose distribution, however, this has generally not been done in small animal research. These results suggest that organ dose errors will be minimized by calibrating the dose rates for all filters, and using different dose rates for different organs.
Collapse
Affiliation(s)
- Matthew D Belley
- Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705
| | - Chu Wang
- Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705
| | - Giao Nguyen
- Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710
| | - Rathnayaka Gunasingha
- Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710
| | - Nelson J Chao
- Department of Medicine, Duke University Medical Center, Durham, North Carolina 27710 and Department of Immunology, Duke University Medical Center, Durham, North Carolina 27710
| | - Benny J Chen
- Department of Medicine, Duke University Medical Center, Durham, North Carolina 27710
| | - Mark W Dewhirst
- Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710
| | - Terry T Yoshizumi
- Duke Radiation Dosimetry Laboratory, Duke University Medical Center, Durham, North Carolina 27710; Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710; and Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710
| |
Collapse
|
31
|
Benhalouche S, Visvikis D, Le Maitre A, Pradier O, Boussion N. Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations. Med Phys 2013; 40:021711. [DOI: 10.1118/1.4774358] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023] Open
|
32
|
Papadimitroulas P, Loudos G, Nikiforidis GC, Kagadis GC. A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: comparison with other Monte Carlo codes. Med Phys 2012; 39:5238-47. [PMID: 22894448 DOI: 10.1118/1.4737096] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. METHODS Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., (177)Lu, (90)Y, and (32)P, and (c) gamma emitting isotopes, e.g., (111)In, (131)I, (125)I, and (99m)Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. RESULTS GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for (67)Ga, (68)Ga, (90)Y, (99m)Tc, (111)In, (123)I, (124)I, (125)I, (131)I, (153)Sm, (177)Lu (186)Re, and (188)Re generated in water, bone, and lung. CONCLUSIONS In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.
Collapse
|
33
|
Sung W, Kim S, Kim JI, Lee JG, Shin YJ, Jung JY, Ye SJ. Dosimetric perturbations due to an implanted cardiac pacemaker in MammoSite® treatment. Med Phys 2012; 39:6185-91. [DOI: 10.1118/1.4752088] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023] Open
|
34
|
D’Amours M, Pouliot J, Dagnault A, Verhaegen F, Beaulieu L. Patient-Specific Monte Carlo-Based Dose-Kernel Approach for Inverse Planning in Afterloading Brachytherapy. Int J Radiat Oncol Biol Phys 2011; 81:1582-9. [DOI: 10.1016/j.ijrobp.2010.09.029] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2010] [Revised: 09/03/2010] [Accepted: 09/21/2010] [Indexed: 11/27/2022]
|
35
|
Parach AA, Rajabi H, Askari MA. Assessment of MIRD data for internal dosimetry using the GATE Monte Carlo code. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2011; 50:441-450. [PMID: 21573984 DOI: 10.1007/s00411-011-0370-0] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2011] [Accepted: 05/01/2011] [Indexed: 05/30/2023]
Abstract
GATE/GEANT is a Monte Carlo code dedicated to nuclear medicine that allows calculation of the dose to organs of voxel phantoms. On the other hand, MIRD is a well-developed system for estimation of the dose to human organs. In this study, results obtained from GATE/GEANT using Snyder phantom are compared to published MIRD data. For this, the mathematical Snyder phantom was discretized and converted to a digital phantom of 100 × 200 × 360 voxels. The activity was considered uniformly distributed within kidneys, liver, lungs, pancreas, spleen, and adrenals. The GATE/GEANT Monte Carlo code was used to calculate the dose to the organs of the phantom from mono-energetic photons of 10, 15, 20, 30, 50, 100, 200, 500, and 1000 keV. The dose was converted into specific absorbed fraction (SAF) and the results were compared to the corresponding published MIRD data. On average, there was a good correlation (r (2)>0.99) between the two series of data. However, the GATE/GEANT data were on average -0.16 ± 6.22% lower than the corresponding MIRD data for self-absorption. Self-absorption in the lungs was considerably higher in the MIRD compared to the GATE/GEANT data, for photon energies of 10-20 keV. As for cross-irradiation to other organs, the GATE/GEANT data were on average +1.5 ± 8.1% higher than the MIRD data, for photon energies of 50-1000 keV. For photon energies of 10-30 keV, the relative difference was +7.5 ± 67%. It turned out that the agreement between the GATE/GEANT and the MIRD data depended upon absolute SAF values and photon energy. For 10-30 keV photons, where the absolute SAF values were small, the uncertainty was high and the effect of cross-section prominent, and there was no agreement between the GATE/GEANT results and the MIRD data. However, for photons of 50-1,000 keV, the bias was negligible and the agreement was acceptable.
Collapse
Affiliation(s)
- Ali Asghar Parach
- Department of Medical Physics, Faculty of Medical Sciences, Tarbiat Modares University, P.O. Box 14115-331, Tehran, Iran
| | | | | |
Collapse
|
36
|
Grevillot L, Frisson T, Maneval D, Zahra N, Badel JN, Sarrut D. Simulation of a 6 MV Elekta Precise Linac photon beam using GATE/GEANT4. Phys Med Biol 2011; 56:903-18. [DOI: 10.1088/0031-9155/56/4/002] [Citation(s) in RCA: 75] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
37
|
Jan S, Benoit D, Becheva E, Carlier T, Cassol F, Descourt P, Frisson T, Grevillot L, Guigues L, Maigne L, Morel C, Perrot Y, Rehfeld N, Sarrut D, Schaart DR, Stute S, Pietrzyk U, Visvikis D, Zahra N, Buvat I. GATE V6: a major enhancement of the GATE simulation platform enabling modelling of CT and radiotherapy. Phys Med Biol 2011; 56:881-901. [DOI: 10.1088/0031-9155/56/4/001] [Citation(s) in RCA: 548] [Impact Index Per Article: 42.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
38
|
Maigne L, Perrot Y, Schaart DR, Donnarieix D, Breton V. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV. Phys Med Biol 2011; 56:811-27. [DOI: 10.1088/0031-9155/56/3/017] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
39
|
Bignell L, Mo L, Alexiev D, Hashemi-Nezhad S. Sensitivity and uncertainty analysis of the simulation of 123I and 54Mn gamma and X-ray emissions in a liquid scintillation vial. Appl Radiat Isot 2010; 68:1495-502. [DOI: 10.1016/j.apradiso.2009.11.051] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|