1
|
Investigation of the effects of the step size of Geant4 electromagnetic physics on the depth dose simulation of a small field proton beam. Radiat Phys Chem Oxf Engl 1993 2022. [DOI: 10.1016/j.radphyschem.2022.110050] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
2
|
Diffenderfer ES, Sørensen BS, Mazal A, Carlson DJ. The current status of preclinical proton FLASH radiation and future directions. Med Phys 2021; 49:2039-2054. [PMID: 34644403 DOI: 10.1002/mp.15276] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Revised: 09/12/2021] [Accepted: 09/17/2021] [Indexed: 11/05/2022] Open
Abstract
We review the current status of proton FLASH experimental systems, including preclinical physical and biological results. Technological limitations on preclinical investigation of FLASH biological mechanisms and determination of clinically relevant parameters are discussed. A review of the biological data reveals no reproduced proton FLASH effect in vitro and a significant in vivo FLASH sparing effect of normal tissue toxicity observed with multiple proton FLASH irradiation systems. Importantly, multiple studies suggest little or no difference in tumor growth delay for proton FLASH when compared to conventional dose rate proton radiation. A discussion follows on future areas of development with a focus on the determination of the optimal parameters for maximizing the therapeutic ratio between tumor and normal tissue response and ultimately clinical translation of proton FLASH radiation.
Collapse
Affiliation(s)
- Eric S Diffenderfer
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | - Brita S Sørensen
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark.,Department of Experimental Clinical Oncology, Aarhus University Hospital, Aarhus, Denmark
| | - Alejandro Mazal
- Department of Medical Physics, Centro de Protonterapia Quironsalud, Madrid, Spain
| | - David J Carlson
- Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania, USA
| |
Collapse
|
3
|
Kim C, Kim YJ, Lee N, Ahn SH, Kim KH, Kim H, Shin D, Lim YK, Jeong JH, Kim DY, Shin WG, Min CH, Lee SB. Evaluation of the dosimetric effect of scattered protons in clinical practice in passive scattering proton therapy. J Appl Clin Med Phys 2021; 22:104-118. [PMID: 34036701 PMCID: PMC8200426 DOI: 10.1002/acm2.13284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 04/08/2021] [Accepted: 04/25/2021] [Indexed: 12/04/2022] Open
Abstract
The present study verified and evaluated the dosimetric effects of protons scattered from a snout and an aperture in clinical practice, when a range compensator was included. The dose distribution calculated by a treatment planning system (TPS) was compared with the measured dose distribution and the dose distribution calculated by Monte Carlo simulation at several depths. The difference between the measured and calculated results was analyzed using Monte Carlo simulation with filtration of scattering in the snout and aperture. The dependence of the effects of scattered protons on snout size, beam range, and minimum thickness of the range compensator was also investigated using the Monte Carlo simulation. The simulated and measured results showed that the additional dose compared with the results calculated by the TPS at shallow depths was mainly due to protons scattered by the snout and aperture. This additional dose was filtered by the structure of the range compensator so that it was observed under the thin region of the range compensator. The maximum difference was measured at a depth of 16 mm (8.25%), with the difference decreasing with depth. Analysis of protons contributing to the additional dose showed that the contribution of protons scattered from the snout was greater than that of protons scattered from the aperture when a narrow snout was used. In the Monte Carlo simulation, this effect of scattered protons was reduced when wider snouts and longer‐range proton beams were used. This effect was also reduced when thicker range compensator bases were used, even with a narrow snout. This study verified the effect of scattered protons even when a range compensator was included and emphasized the importance of snout‐scattered protons when a narrow snout is used for small fields. It indicated that this additional dose can be reduced by wider snouts, longer range proton beams, and thicker range compensator bases. These results provide a better understanding of the additional dose from scattered protons in clinical practice.
Collapse
Affiliation(s)
- Chankyu Kim
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Yeon-Joo Kim
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Nuri Lee
- Department of Radiation Oncology, National Medical Center, Seoul, Republic of Korea
| | - Sang Hee Ahn
- Department of Radiation Oncology, Yonsei Cancer Center, Yonsei University College of Medicine, Seoul, Republic of Korea
| | - Kwang Hyeon Kim
- Department of Neurosurgery, Inje University Ilsan Paik Hospital, Gyeonggi-do, Republic of Korea
| | - Haksoo Kim
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Dongho Shin
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Young Kyung Lim
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Jong Hwi Jeong
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Dae Yong Kim
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| | - Wook-Geun Shin
- Department of Radiation Oncology, Seoul National University Hospital, Seoul, Republic of Korea
| | - Chul Hee Min
- Department of Radiation Convergence Engineering, Yonsei University, Gangwon-do, Republic of Korea
| | - Se Byeong Lee
- Proton Therapy Center, National Cancer Center Korea, Gyeonggi-do, Republic of Korea
| |
Collapse
|
4
|
De Marzi L, Patriarca A, Scher N, Thariat J, Vidal M. Exploiting the full potential of proton therapy: An update on the specifics and innovations towards spatial or temporal optimisation of dose delivery. Cancer Radiother 2020; 24:691-698. [PMID: 32753235 DOI: 10.1016/j.canrad.2020.06.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2020] [Revised: 06/07/2020] [Accepted: 06/09/2020] [Indexed: 02/07/2023]
Abstract
Prescription and delivery of protons are somewhat different compared to photons and may influence outcomes (tumour control and toxicity). These differences should be taken into account to fully exploit the clinical potential of proton therapy. Innovations in proton therapy treatment are also required to widen the therapeutic window and determine appropriate populations of patients that would benefit from new treatments. Therefore, strategies are now being developed to reduce side effects to critical normal tissues using alternative treatment configurations and new spatial or temporal-driven optimisation approaches. Indeed, spatiotemporal optimisation (based on flash, proton minibeam radiation therapy or hypofractionated delivery methods) has been gaining some attention in proton therapy as a mean of improving (biological and physical) dose distribution. In this short review, the main differences in planning and delivery between protons and photons, as well as some of the latest developments and methodological issues (in silico modelling) related to providing scientific evidence for these new techniques will be discussed.
Collapse
Affiliation(s)
- L De Marzi
- Institut Curie, centre de protonthérapie d'Orsay, campus universitaire, bâtiment 101, 91898 Orsay, France; Université PSL (Paris Sciences & Lettres), 60, rue Mazarine, 75006 Paris, France; Université Paris-Saclay, route de l'Orme-aux-Merisiers, RD 128, 91190 Saint-Aubin, France; Inserm U1021, centre universitaire, bâtiment 110, rue Henri-Becquerel, 91405 Orsay cedex, France; CNRS, UMR 3347, centre universitaire, bâtiment 110, rue Henri-Becquerel, 91405 Orsay cedex, France.
| | - A Patriarca
- Institut Curie, centre de protonthérapie d'Orsay, campus universitaire, bâtiment 101, 91898 Orsay, France; Université PSL (Paris Sciences & Lettres), 60, rue Mazarine, 75006 Paris, France
| | - N Scher
- Institut Curie, centre de protonthérapie d'Orsay, campus universitaire, bâtiment 101, 91898 Orsay, France; Université PSL (Paris Sciences & Lettres), 60, rue Mazarine, 75006 Paris, France
| | - J Thariat
- Service de radiothérapie oncologique, centre François-Baclesse, 3, avenue General-Harris, 14000 Caen, France; Laboratoire de physique corpusculaire de Caen, 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France; Institut national de physique nucléaire et physique des particules (IN2P3), 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France; EnsiCaen, 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France; CNRS, UMR6534, 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France; Unicaen, 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France; Normandie Université, 6, boulevard du Maréchal-Juin, 14050 Caen cedex, France
| | - M Vidal
- Centre Antoine-Lacassagne, 33, avenue Valombrose, 06000 Nice, France
| |
Collapse
|
5
|
Teoh S, Fiorini F, George B, Vallis KA, Van den Heuvel F. Is an analytical dose engine sufficient for intensity modulated proton therapy in lung cancer? Br J Radiol 2020; 93:20190583. [PMID: 31696729 PMCID: PMC7066954 DOI: 10.1259/bjr.20190583] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 11/02/2019] [Accepted: 11/04/2019] [Indexed: 12/16/2022] Open
Abstract
OBJECTIVE To identify a subgroup of lung cancer plans where the analytical dose calculation (ADC) algorithm may be clinically acceptable compared to Monte Carlo (MC) dose calculation in intensity modulated proton therapy (IMPT). METHODS Robust-optimised IMPT plans were generated for 20 patients to a dose of 70 Gy (relative biological effectiveness) in 35 fractions in Raystation. For each case, four plans were generated: three with ADC optimisation using the pencil beam (PB) algorithm followed by a final dose calculation with the following algorithms: PB (PB-PB), MC (PB-MC) and MC normalised to prescription dose (PB-MC scaled). A fourth plan was generated where MC optimisation and final dose calculation was performed (MC-MC). Dose comparison and γ analysis (PB-PB vs PB-MC) at two dose thresholds were performed: 20% (D20) and 99% (D99) with PB-PB plans as reference. RESULTS Overestimation of the dose to 99% and mean dose of the clinical target volume was observed in all PB-MC compared to PB-PB plans (median: 3.7 Gy(RBE) (5%) (range: 2.3 to 6.9 Gy(RBE)) and 1.8 Gy(RBE) (3%) (0.5 to 4.6 Gy(RBE))). PB-MC scaled plans resulted in significantly higher CTVD2 compared to PB-PB (median difference: -4 Gy(RBE) (-6%) (-5.3 to -2.4 Gy(RBE)), p ≤ .001). The overall median γ pass rates (3%-3 mm) at D20 and D99 were 93.2% (range:62.2-97.5%) and 71.3 (15.4-92.0%). On multivariate analysis, presence of mediastinal disease and absence of range shifters were significantly associated with high γ pass rates. Median D20 and D99 pass rates with these predictors were 96.0% (95.3-97.5%) and 85.4% (75.1-92.0%). MC-MC achieved similar target coverage and doses to OAR compared to PB-PB plans. CONCLUSION In the presence of mediastinal involvement and absence of range shifters Raystation ADC may be clinically acceptable in lung IMPT. Otherwise, MC algorithm would be recommended to ensure accuracy of treatment plans. ADVANCES IN KNOWLEDGE Although MC algorithm is more accurate compared to ADC in lung IMPT, ADC may be clinically acceptable where there is mediastinal involvement and absence of range shifters.
Collapse
|
6
|
DePew KD, Ahmad S, Jin H. Experimental Assessment of Proton Dose Calculation Accuracy in Small-Field Delivery Using a Mevion S250 Proton Therapy System. J Med Phys 2019; 43:221-229. [PMID: 30636847 PMCID: PMC6299753 DOI: 10.4103/jmp.jmp_33_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Purpose: Dose calculation accuracy of the Varian Eclipse treatment planning system (TPS) is empirically assessed for small-aperture fields using a Mevion S250 double scattering proton therapy system. Materials and Methods: Five spherical pseudotumors were modeled in a RANDO head phantom. Plans were generated for the targets with apertures of 1, 2, 3, 4, or 5 cm diameter using one, two, and three beams. Depth-dose curves and lateral profiles of the beams were taken with the planned blocks and compared to Eclipse calculations. Dose distributions measured with EBT3 films in the phantom were also compared to Eclipse calculations. Film quenching effect was simulated and considered. Results: Depth-dose scans in water showed a range pullback (up to 2.0 mm), modulation widening (up to 9.5 mm), and dose escalation in proximal end and sub-peak region (up to 15.5%) when compared to the Eclipse calculations for small fields. Measured full width at half maximum and penumbrae for lateral profiles differed <1.0 mm from calculations for most comparisons. In the phantom study, Eclipse TPS underestimated sub-peak dose. Gamma passing rates improved with each beam added to the plans. Greater range pullback and modulation degradation versus water scans were observed due to film quenching, which became more noticeable as target size increased. Conclusions: Eclipse TPS generates acceptable target coverage for small targets with carefully arranged multiple beams despite relatively large dose discrepancy for each beam. Surface doses higher than Eclipse calculations can be mitigated with multiple beams. When using EBT3 film, the quenching effect should be considered.
Collapse
Affiliation(s)
- Kyle D DePew
- Department of Radiation Oncology, University of Oklahoma Health Sciences Centre, Oklahoma City, Oklahoma, USA
| | - Salahuddin Ahmad
- Department of Radiation Oncology, University of Oklahoma Health Sciences Centre, Oklahoma City, Oklahoma, USA
| | - Hosang Jin
- Department of Radiation Oncology, University of Oklahoma Health Sciences Centre, Oklahoma City, Oklahoma, USA
| |
Collapse
|
7
|
Proton therapy for treatment of intracranial benign tumors in adults: A systematic review. Cancer Treat Rev 2018; 72:56-64. [PMID: 30530009 DOI: 10.1016/j.ctrv.2018.11.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Revised: 11/28/2018] [Accepted: 11/30/2018] [Indexed: 11/21/2022]
Abstract
INTRODUCTION The depth-dose distribution of a proton beam, materialized by the Bragg peak makes it an attractive radiation modality as it reduces exposure of healthy tissues to radiations, compared with photon therapy Prominent indications, based on a long-standing experience are: intraocular melanomas, low-grade skull-base and spinal canal malignancies. However, many others potential indications are under investigations such as the benign morbid conditions that are compatible with an extended life-expectancy: low grade meningiomas, paragangliomas, pituitary adenomas, neurinomas craniopharyngioma or recurrent pleomorphic adenomas. MATERIALS Given the radiation-induced risk of secondary cancer and the potential neurocognitive and functional alteration with photonic radiotherapy, we systematically analyzed the existing clinical literature about the use of proton therapy as an irradiation modality for cervical or intracranial benign tumors. The aim of this review was to report clinical outcomes of adult patients with benign intracranial or cervical tumors treated with proton therapy and to discuss about potential advantages of proton therapy over intensity modulated radiotherapy or radiosurgery. RESULTS Twenty-four studies were included. There was no randomized studies. Most studies dealt with low grade meningiomas (n = 9). Studies concerning neurinoma (n = 4), pituitary adenoma (n = 5), paraganglioma (n = 5), or craniopharyngioma (n = 1) were fewer. Whatever the indication, long term local control was systematically higher than 90% and equivalent to series with conventional radiotherapy. CONCLUSION Proton-therapy for treatment of adult benign intracranial and cervical tumors is safe. Randomized or prospective cohorts with long term cognitive evaluations are needed to assess the real place of proton-therapy in the treatment of adults benign head and neck tumors.
Collapse
|
8
|
Bednarz B, Grudzinski J, Marsh I, Besemer A, Baiu D, Weichert J, Otto M. Murine-specific Internal Dosimetry for Preclinical Investigations of Imaging and Therapeutic Agents. HEALTH PHYSICS 2018; 114:450-459. [PMID: 29481536 PMCID: PMC5831541 DOI: 10.1097/hp.0000000000000789] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
There is a growing need to estimate the absorbed dose to small animals from preclinical investigations involving diagnostic and therapeutic radiopharmaceuticals. This paper introduces a Monte Carlo-based dosimetry platform called RAPID, which is capable of calculating murine-specific three-dimensional (3D) dose distributions. A comparison is performed between absorbed doses calculated with RAPID and absorbed doses calculated in a commonly used reference mouse phantom called MOBY. Four test mice containing different xenografts underwent serial PET/CT imaging using a novel diagnostic therapy (theranostic) agent NM404, which can be labeled with I for imaging or I for therapy. Using the PET/CT data, 3D dose distributions from I-NM404 were calculated in the mice using RAPID. Mean organ doses in these four test mice were compared to mean organ doses derived by using two previously published I S-values datasets in MOBY. In addition, mean tumor doses calculated in RAPID were compared to mean organ doses derived from unit density spheres. Large differences were identified between mean organ doses calculated in the test mice using RAPID and those derived in the MOBY phantom. Mean absorbed dose percent errors in organs ranged between 0.3% and 333%. Overall, mass scaling improved agreement between MOBY phantom calculations and RAPID, where percent errors were all less than 26%, with the exception of the lung in which percent errors reached values of 48%. Percent errors in mean tumor doses in the test mice and unit density spheres were less pronounced but still ranged between 8% and 23%. This work demonstrates the limitations of using pre-computed S-values in computational phantoms to predict organ doses in small animals from theranostic procedures. RAPID can generate accurate 3D dose distributions in small animals and in turn offer much greater insight on the ability of a given theranostic agent to image and treat diseases.
Collapse
|
9
|
Lin YC, Pan C, Chiang K, Yuan M, Chu C, Tsai Y, Teng P, Lin C, Chao T, Lee C, Tung C, Chen A. Monte Carlo simulations for angular and spatial distributions in therapeutic-energy proton beams. Radiat Phys Chem Oxf Engl 1993 2017. [DOI: 10.1016/j.radphyschem.2017.03.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
10
|
Geng C, Daartz J, Lam-Tin-Cheung K, Bussiere M, Shih HA, Paganetti H, Schuemann J. Limitations of analytical dose calculations for small field proton radiosurgery. Phys Med Biol 2016; 62:246-257. [DOI: 10.1088/1361-6560/62/1/246] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
11
|
Durante M, Paganetti H. Nuclear physics in particle therapy: a review. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2016; 79:096702. [PMID: 27540827 DOI: 10.1088/0034-4885/79/9/096702] [Citation(s) in RCA: 145] [Impact Index Per Article: 18.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Charged particle therapy has been largely driven and influenced by nuclear physics. The increase in energy deposition density along the ion path in the body allows reducing the dose to normal tissues during radiotherapy compared to photons. Clinical results of particle therapy support the physical rationale for this treatment, but the method remains controversial because of the high cost and of the lack of comparative clinical trials proving the benefit compared to x-rays. Research in applied nuclear physics, including nuclear interactions, dosimetry, image guidance, range verification, novel accelerators and beam delivery technologies, can significantly improve the clinical outcome in particle therapy. Measurements of fragmentation cross-sections, including those for the production of positron-emitting fragments, and attenuation curves are needed for tuning Monte Carlo codes, whose use in clinical environments is rapidly increasing thanks to fast calculation methods. Existing cross sections and codes are indeed not very accurate in the energy and target regions of interest for particle therapy. These measurements are especially urgent for new ions to be used in therapy, such as helium. Furthermore, nuclear physics hardware developments are frequently finding applications in ion therapy due to similar requirements concerning sensors and real-time data processing. In this review we will briefly describe the physics bases, and concentrate on the open issues.
Collapse
Affiliation(s)
- Marco Durante
- Trento Institute for Fundamental Physics and Applications (TIFPA), National Institute of Nuclear Physics (INFN), University of Trento, Via Sommarive 14, 38123 Povo (TN), Italy. Department of Physics, University Federico II, Naples, Italy
| | | |
Collapse
|
12
|
Polf JC, Chuong M, Zhang B, Mehta M. Anteriorly Oriented Beam Arrangements with Daily in Vivo Range Verification for Proton Therapy of Prostate Cancer: Rectal Toxicity Rates. Int J Part Ther 2016; 2:509-517. [PMID: 31772963 DOI: 10.14338/ijpt-15-00015.1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Accepted: 08/17/2015] [Indexed: 11/21/2022] Open
Abstract
Purpose To model whether in vivo range verification could reduce high-grade rectal toxicity for patients with prostate cancer treated with pencil beam scanning proton therapy by allowing novel proton beam arrangements compared to standard lateral opposed beams. Materials and Methods Proton plans were generated for 8 patients with prostate cancer previously treated with photons by volumetric-modulated arc therapy (VMAT). The VMAT plans were generated by using a uniform 6-mm planning target volume (PTV) expansion. For the proton plans an additional distal margin (3.5% of beam range) was added to the uniform 6-mm PTV to account for range uncertainty, using 3 beam arrangements: (1) lateral opposed beams (LAT), (2) left and right anterior oblique beams (LAO/RAO), and (3) a single anterior-posterior beam (AP). Assuming use of in vivo range verification, plans were generated by using a reduced distal PTV and distal range uncertainty expansion (2 mm each) with AP (AP-2 mm) and LAO/RAO (LAO/RAO-2 mm) beam arrangements. Estimates of normal tissue complication probability (NTCP) for ≥grade 2 rectal bleeding were generated by using the Lyman-Kutcher-Burman model. Results Each proton and photon plan was able to achieve all prespecified rectal and bladder constraints. For the VMAT, LAT, AP, and LAO/RAO plans, estimated NTCP values for ≥grade 2 rectal bleeding were 0.19, 0.21, 0.24, and 0.2, respectively. For the AP-2 mm and LAO/RAO-2 mm plans, NTCP values were reduced to 0.11 and 0.1 with respect to ≥grade 2 rectal bleeding. Conclusion Presuming that in vivo range verification for pencil beam scanning proton therapy could localize the distal falloff of the Bragg peak to within 2 mm, novel beam arrangements (AP and LAO/RAO) may reduce the risk of serious rectal bleeding, compared to VMAT and LAT proton treatment techniques. These are achieved without an increase in modeled bladder complication rates.
Collapse
Affiliation(s)
- Jerimy C Polf
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Michael Chuong
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Bin Zhang
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| | - Minesh Mehta
- Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, MD, USA
| |
Collapse
|
13
|
Abstract
The physics of proton therapy has advanced considerably since it was proposed in 1946. Today analytical equations and numerical simulation methods are available to predict and characterize many aspects of proton therapy. This article reviews the basic aspects of the physics of proton therapy, including proton interaction mechanisms, proton transport calculations, the determination of dose from therapeutic and stray radiations, and shielding design. The article discusses underlying processes as well as selected practical experimental and theoretical methods. We conclude by briefly speculating on possible future areas of research of relevance to the physics of proton therapy.
Collapse
Affiliation(s)
- Wayne D Newhauser
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA, 70803, USA
- Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA, 70809, USA
| | - Rui Zhang
- Medical Physics Program, Department of Physics and Astronomy, Louisiana State University, 202 Nicholson Hall, Baton Rouge, LA, 70803, USA
- Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA, 70809, USA
| |
Collapse
|
14
|
Schuemann J, Giantsoudi D, Grassberger C, Moteabbed M, Min CH, Paganetti H. Assessing the Clinical Impact of Approximations in Analytical Dose Calculations for Proton Therapy. Int J Radiat Oncol Biol Phys 2015; 92:1157-1164. [PMID: 26025779 DOI: 10.1016/j.ijrobp.2015.04.006] [Citation(s) in RCA: 69] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2014] [Revised: 03/13/2015] [Accepted: 04/02/2015] [Indexed: 11/29/2022]
Abstract
PURPOSE To assess the impact of approximations in current analytical dose calculation methods (ADCs) on tumor control probability (TCP) in proton therapy. METHODS Dose distributions planned with ADC were compared with delivered dose distributions as determined by Monte Carlo simulations. A total of 50 patients were investigated in this analysis with 10 patients per site for 5 treatment sites (head and neck, lung, breast, prostate, liver). Differences were evaluated using dosimetric indices based on a dose-volume histogram analysis, a γ-index analysis, and estimations of TCP. RESULTS We found that ADC overestimated the target doses on average by 1% to 2% for all patients considered. The mean dose, D95, D50, and D02 (the dose value covering 95%, 50% and 2% of the target volume, respectively) were predicted within 5% of the delivered dose. The γ-index passing rate for target volumes was above 96% for a 3%/3 mm criterion. Differences in TCP were up to 2%, 2.5%, 6%, 6.5%, and 11% for liver and breast, prostate, head and neck, and lung patients, respectively. Differences in normal tissue complication probabilities for bladder and anterior rectum of prostate patients were less than 3%. CONCLUSION Our results indicate that current dose calculation algorithms lead to underdosage of the target by as much as 5%, resulting in differences in TCP of up to 11%. To ensure full target coverage, advanced dose calculation methods like Monte Carlo simulations may be necessary in proton therapy. Monte Carlo simulations may also be required to avoid biases resulting from systematic discrepancies in calculated dose distributions for clinical trials comparing proton therapy with conventional radiation therapy.
Collapse
Affiliation(s)
- Jan Schuemann
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts.
| | - Drosoula Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Clemens Grassberger
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Maryam Moteabbed
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Chul Hee Min
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
15
|
Schuemann J, Dowdell S, Grassberger C, Min CH, Paganetti H. Site-specific range uncertainties caused by dose calculation algorithms for proton therapy. Phys Med Biol 2014; 59:4007-31. [PMID: 24990623 DOI: 10.1088/0031-9155/59/15/4007] [Citation(s) in RCA: 90] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The purpose of this study was to assess the possibility of introducing site-specific range margins to replace current generic margins in proton therapy. Further, the goal was to study the potential of reducing margins with current analytical dose calculations methods. For this purpose we investigate the impact of complex patient geometries on the capability of analytical dose calculation algorithms to accurately predict the range of proton fields. Dose distributions predicted by an analytical pencil-beam algorithm were compared with those obtained using Monte Carlo (MC) simulations (TOPAS). A total of 508 passively scattered treatment fields were analyzed for seven disease sites (liver, prostate, breast, medulloblastoma-spine, medulloblastoma-whole brain, lung and head and neck). Voxel-by-voxel comparisons were performed on two-dimensional distal dose surfaces calculated by pencil-beam and MC algorithms to obtain the average range differences and root mean square deviation for each field for the distal position of the 90% dose level (R90) and the 50% dose level (R50). The average dose degradation of the distal falloff region, defined as the distance between the distal position of the 80% and 20% dose levels (R80-R20), was also analyzed. All ranges were calculated in water-equivalent distances. Considering total range uncertainties and uncertainties from dose calculation alone, we were able to deduce site-specific estimations. For liver, prostate and whole brain fields our results demonstrate that a reduction of currently used uncertainty margins is feasible even without introducing MC dose calculations. We recommend range margins of 2.8% + 1.2 mm for liver and prostate treatments and 3.1% + 1.2 mm for whole brain treatments, respectively. On the other hand, current margins seem to be insufficient for some breast, lung and head and neck patients, at least if used generically. If no case specific adjustments are applied, a generic margin of 6.3% + 1.2 mm would be needed for breast, lung and head and neck treatments. We conclude that the currently used generic range uncertainty margins in proton therapy should be redefined site specific and that complex geometries may require a field specific adjustment. Routine verifications of treatment plans using MC simulations are recommended for patients with heterogeneous geometries.
Collapse
Affiliation(s)
- J Schuemann
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA
| | | | | | | | | |
Collapse
|
16
|
Bueno M, Paganetti H, Duch MA, Schuemann J. An algorithm to assess the need for clinical Monte Carlo dose calculation for small proton therapy fields based on quantification of tissue heterogeneity. Med Phys 2014; 40:081704. [PMID: 23927301 DOI: 10.1118/1.4812682] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
PURPOSE In proton therapy, complex density heterogeneities within the beam path constitute a challenge to dose calculation algorithms. This might question the reliability of dose distributions predicted by treatment planning systems based on analytical dose calculation. For cases in which substantial dose errors are expected, resorting to Monte Carlo dose calculations might be essential to ensure a successful treatment outcome and therefore the benefit is worth a presumably long computation time. The aim of this study was to define an indicator for the accuracy of dose delivery based on analytical dose calculations in treatment planning systems for small proton therapy fields to identify those patients for which Monte Carlo dose calculation is warranted. METHODS Fourteen patients treated at our facility with small passively scattered proton beams (apertures diameters below 7 cm) were selected. Plans were generated in the XiO treatment planning system in combination with a pencil beam algorithm developed at the Massachusetts General Hospital and compared to Monte Carlo dose calculations. Differences in the dose to the 50% of the gross tumor volume (D50, GTV) were assessed in a field-by-field basis. A simple and fast methodology was developed to quantify the inhomogeneity of the tissue traversed by a single small proton beam using a heterogeneity index (HI)-a concept presented by Plugfelder et al. [Med. Phys. 34, 1506-1513 (2007)] for scanned proton beams. Finally, the potential correlation between the error made by the pencil beam based treatment planning algorithm for each field and the level of tissue heterogeneity traversed by the proton beam given by the HI was evaluated. RESULTS Discrepancies up to 5.4% were found in D50 for single fields, although dose differences were within clinical tolerance levels (<3%) when combining all of the fields involved in the treatment. The discrepancies found for each field exhibited a strong correlation to their associated HI-values (Spearman's ρ=0.8, p<0.0001); the higher the level of tissue inhomogeneities for a particular field, the larger the error by the analytical algorithm. With the established correlation a threshold for HI can be set by choosing a tolerance level of 2-3%-commonly accepted in radiotherapy. CONCLUSIONS The HI is a good indicator for the accuracy of proton field delivery in terms of GTV prescription dose coverage when small fields are delivered. Each HI-value was obtained from the CT image in less than 3 min on a computer with 2 GHz CPU allowing implementation of this methodology in clinical routine. For HI-values exceeding the threshold, either a change in beam direction (if feasible) or a recalculation of the dose with Monte Carlo would be highly recommended.
Collapse
Affiliation(s)
- M Bueno
- Departament de Dosimetria i Física Mèdica, Institut de Tècniques Energètiques, Universitat Politècnica de Catalunya, 08028 Barcelona, Spain.
| | | | | | | |
Collapse
|
17
|
McDonald MW, Wolanski MR, Simmons JW, Buchsbaum JC. Technique for sparing previously irradiated critical normal structures in salvage proton craniospinal irradiation. Radiat Oncol 2013; 8:14. [PMID: 23311343 PMCID: PMC3556160 DOI: 10.1186/1748-717x-8-14] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2012] [Accepted: 12/27/2012] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Cranial reirradiation is clinically appropriate in some cases but cumulative radiation dose to critical normal structures remains a practical concern. The authors developed a simple technique in 3D conformal proton craniospinal irradiation (CSI) to block organs at risk (OAR) while minimizing underdosing of adjacent target brain tissue. METHODS Two clinical cases illustrate the use of proton therapy to provide salvage CSI when a previously irradiated OAR required sparing from additional radiation dose. The prior radiation plan was coregistered to the treatment planning CT to create a planning organ at risk volume (PRV) around the OAR. Right and left lateral cranial whole brain proton apertures were created with a small block over the PRV. Then right and left lateral "inverse apertures" were generated, creating an aperture opening in the shape of the area previously blocked and blocking the area previously open. The inverse aperture opening was made one millimeter smaller than the original block to minimize the risk of dose overlap. The inverse apertures were used to irradiate the target volume lateral to the PRV, selecting a proton beam range to abut the 50% isodose line against either lateral edge of the PRV. Together, the 4 cranial proton fields created a region of complete dose avoidance around the OAR. Comparative photon treatment plans were generated with opposed lateral X-ray fields with custom blocks and coplanar intensity modulated radiation therapy optimized to avoid the PRV. Cumulative dose volume histograms were evaluated. RESULTS Treatment plans were developed and successfully implemented to provide sparing of previously irradiated critical normal structures while treating target brain lateral to these structures. The absence of dose overlapping during irradiation through the inverse apertures was confirmed by film. Compared to the lateral X-ray and IMRT treatment plans, the proton CSI technique improved coverage of target brain tissue while providing the least additional radiation dose to the previously irradiated OAR. CONCLUSIONS Proton craniospinal irradiation can be adapted to provide complete sparing of previously irradiated OARs. This technique may extend the option of reirradiation to patients otherwise deemed ineligible for further radiotherapy due to prior dose to critical normal structures.
Collapse
Affiliation(s)
- Mark W McDonald
- Department of Radiation Oncology, Indiana University School of Medicine, Indianapolis, IN, USA.
| | | | | | | |
Collapse
|
18
|
Yamashita T, Akagi T, Aso T, Kimura A, Sasaki T. Effect of inhomogeneity in a patient's body on the accuracy of the pencil beam algorithm in comparison to Monte Carlo. Phys Med Biol 2012; 57:7673-88. [PMID: 23123683 DOI: 10.1088/0031-9155/57/22/7673] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
The pencil beam algorithm (PBA) is reasonably accurate and fast. It is, therefore, the primary method used in routine clinical treatment planning for proton radiotherapy; still, it needs to be validated for use in highly inhomogeneous regions. In our investigation of the effect of patient inhomogeneity, PBA was compared with Monte Carlo (MC). A software framework was developed for the MC simulation of radiotherapy based on Geant4. Anatomical sites selected for the comparison were the head/neck, liver, lung and pelvis region. The dose distributions calculated by the two methods in selected examples were compared, as well as a dose volume histogram (DVH) derived from the dose distributions. The comparison of the off-center ratio (OCR) at the iso-center showed good agreement between the PBA and MC, while discrepancies were seen around the distal fall-off regions. While MC showed a fine structure on the OCR in the distal fall-off region, the PBA showed smoother distribution. The fine structures in MC calculation appeared downstream of very low-density regions. Comparison of DVHs showed that most of the target volumes were similarly covered, while some OARs located around the distal region received a higher dose when calculated by MC than the PBA.
Collapse
Affiliation(s)
- T Yamashita
- Hyogo Ion Beam Medical Center, Shingu-cho, Tatsuno, Hyogo, Japan.
| | | | | | | | | |
Collapse
|
19
|
Zhao L, Newton J, Oldham M, Das IJ, Cheng CW, Adamovics J. Feasibility of using PRESAGE® for relative 3D dosimetry of small proton fields. Phys Med Biol 2012; 57:N431-43. [PMID: 23103526 DOI: 10.1088/0031-9155/57/22/n431] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
Small field dosimetry is challenging due to the finite size of the conventional detectors that underestimate the dose distribution. With the fast development of the dynamic proton beam delivery system, it is essential to find a dosimeter which can be used for 3D dosimetry of small proton fields. We investigated the feasibility of using a proton formula PRESAGE® for 3D dosimetry of small fields in a uniform scanning proton beam delivery system with dose layer stacking technology. The relationship between optical density and the absorbed dose was found to be linear through small volume cuvette studies for both photon and proton irradiation. Two circular fields and three patient-specific fields were used for proton treatment planning calculation and beam delivery. The measured results were compared with the calculated results in the form of lateral dose profiles, depth dose, isodose plots and gamma index analysis. For the circular field study, lateral dose profile comparison showed that the relative PRESAGE® profile falls within ± 5% from the calculated profile for most of the spatial range. For unmodulated depth dose comparison, the agreement between the measured and calculated results was within 3% in the beam entrance region before the Bragg peak. However, at the Bragg peak, there was about 20% underestimation of the absorbed dose from PRESAGE®. For patient-specific field 3D dosimetry, most of the data points within the target volume passed gamma analysis for 3% relative dose difference and 3 mm distance to agreement criteria. Our results suggest that this proton formula PRESAGE® dosimeter has the potential for 3D dosimetry of small fields in proton therapy, but further investigation is needed to improve the dose under-response of the PRESAGE® in the Bragg peak region.
Collapse
Affiliation(s)
- Li Zhao
- Indiana University Health Proton Therapy Center, Bloomington, IN, USA
| | | | | | | | | | | |
Collapse
|
20
|
Abstract
The main advantages of proton therapy are the reduced total energy deposited in the patient as compared to photon techniques and the finite range of the proton beam. The latter adds an additional degree of freedom to treatment planning. The range in tissue is associated with considerable uncertainties caused by imaging, patient setup, beam delivery and dose calculation. Reducing the uncertainties would allow a reduction of the treatment volume and thus allow a better utilization of the advantages of protons. This paper summarizes the role of Monte Carlo simulations when aiming at a reduction of range uncertainties in proton therapy. Differences in dose calculation when comparing Monte Carlo with analytical algorithms are analyzed as well as range uncertainties due to material constants and CT conversion. Range uncertainties due to biological effects and the role of Monte Carlo for in vivo range verification are discussed. Furthermore, the current range uncertainty recipes used at several proton therapy facilities are revisited. We conclude that a significant impact of Monte Carlo dose calculation can be expected in complex geometries where local range uncertainties due to multiple Coulomb scattering will reduce the accuracy of analytical algorithms. In these cases Monte Carlo techniques might reduce the range uncertainty by several mm.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| |
Collapse
|
21
|
Paganetti H. Range uncertainties in proton therapy and the role of Monte Carlo simulations. Phys Med Biol 2012. [PMID: 22571913 DOI: 10.1088/0031‐9155/57/11/r99] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The main advantages of proton therapy are the reduced total energy deposited in the patient as compared to photon techniques and the finite range of the proton beam. The latter adds an additional degree of freedom to treatment planning. The range in tissue is associated with considerable uncertainties caused by imaging, patient setup, beam delivery and dose calculation. Reducing the uncertainties would allow a reduction of the treatment volume and thus allow a better utilization of the advantages of protons. This paper summarizes the role of Monte Carlo simulations when aiming at a reduction of range uncertainties in proton therapy. Differences in dose calculation when comparing Monte Carlo with analytical algorithms are analyzed as well as range uncertainties due to material constants and CT conversion. Range uncertainties due to biological effects and the role of Monte Carlo for in vivo range verification are discussed. Furthermore, the current range uncertainty recipes used at several proton therapy facilities are revisited. We conclude that a significant impact of Monte Carlo dose calculation can be expected in complex geometries where local range uncertainties due to multiple Coulomb scattering will reduce the accuracy of analytical algorithms. In these cases Monte Carlo techniques might reduce the range uncertainty by several mm.
Collapse
Affiliation(s)
- Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
| |
Collapse
|