Thorwarth D. Clinical use of positron emission tomography for radiotherapy planning - Medical physics considerations. Z Med Phys 2023; 33:13-21. [PMID: 36272949 PMCID: PMC10068574 DOI: 10.1016/j.zemedi.2022.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 08/17/2022] [Accepted: 09/21/2022] [Indexed: 11/06/2022]
Abstract
PET/CT imaging plays an increasing role in radiotherapy treatment planning. The aim of this article was to identify the major use cases and technical as well as medical physics challenges during integration of these data into treatment planning. Dedicated aspects, such as (i) PET/CT-based radiotherapy simulation, (ii) PET-based target volume delineation, (iii) functional avoidance to optimized organ-at-risk sparing and (iv) functionally adapted individualized radiotherapy are discussed in this article. Furthermore, medical physics aspects to be taken into account are summarized and presented in form of check-lists.
Collapse
Affiliation(s)
- Daniela Thorwarth
- Section for Biomedical Physics, Department of Radiation Oncology, University of Tübingen, Tübingen, Germany; German Cancer Consortium (DKTK), partner site Tübingen; and German Cancer Research Center (DKFZ), Heidelberg, Germany.
| |
Collapse
|
2
|
Hatt M, Lee JA, Schmidtlein CR, Naqa IE, Caldwell C, De Bernardi E, Lu W, Das S, Geets X, Gregoire V, Jeraj R, MacManus MP, Mawlawi OR, Nestle U, Pugachev AB, Schöder H, Shepherd T, Spezi E, Visvikis D, Zaidi H, Kirov AS. Classification and evaluation strategies of auto-segmentation approaches for PET: Report of AAPM task group No. 211. Med Phys 2017; 44:e1-e42. [PMID: 28120467 DOI: 10.1002/mp.12124] [Citation(s) in RCA: 134] [Impact Index Per Article: 19.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2016] [Revised: 12/09/2016] [Accepted: 01/04/2017] [Indexed: 12/14/2022] Open
Abstract
PURPOSE The purpose of this educational report is to provide an overview of the present state-of-the-art PET auto-segmentation (PET-AS) algorithms and their respective validation, with an emphasis on providing the user with help in understanding the challenges and pitfalls associated with selecting and implementing a PET-AS algorithm for a particular application. APPROACH A brief description of the different types of PET-AS algorithms is provided using a classification based on method complexity and type. The advantages and the limitations of the current PET-AS algorithms are highlighted based on current publications and existing comparison studies. A review of the available image datasets and contour evaluation metrics in terms of their applicability for establishing a standardized evaluation of PET-AS algorithms is provided. The performance requirements for the algorithms and their dependence on the application, the radiotracer used and the evaluation criteria are described and discussed. Finally, a procedure for algorithm acceptance and implementation, as well as the complementary role of manual and auto-segmentation are addressed. FINDINGS A large number of PET-AS algorithms have been developed within the last 20 years. Many of the proposed algorithms are based on either fixed or adaptively selected thresholds. More recently, numerous papers have proposed the use of more advanced image analysis paradigms to perform semi-automated delineation of the PET images. However, the level of algorithm validation is variable and for most published algorithms is either insufficient or inconsistent which prevents recommending a single algorithm. This is compounded by the fact that realistic image configurations with low signal-to-noise ratios (SNR) and heterogeneous tracer distributions have rarely been used. Large variations in the evaluation methods used in the literature point to the need for a standardized evaluation protocol. CONCLUSIONS Available comparison studies suggest that PET-AS algorithms relying on advanced image analysis paradigms provide generally more accurate segmentation than approaches based on PET activity thresholds, particularly for realistic configurations. However, this may not be the case for simple shape lesions in situations with a narrower range of parameters, where simpler methods may also perform well. Recent algorithms which employ some type of consensus or automatic selection between several PET-AS methods have potential to overcome the limitations of the individual methods when appropriately trained. In either case, accuracy evaluation is required for each different PET scanner and scanning and image reconstruction protocol. For the simpler, less robust approaches, adaptation to scanning conditions, tumor type, and tumor location by optimization of parameters is necessary. The results from the method evaluation stage can be used to estimate the contouring uncertainty. All PET-AS contours should be critically verified by a physician. A standard test, i.e., a benchmark dedicated to evaluating both existing and future PET-AS algorithms needs to be designed, to aid clinicians in evaluating and selecting PET-AS algorithms and to establish performance limits for their acceptance for clinical use. The initial steps toward designing and building such a standard are undertaken by the task group members.
Collapse
Affiliation(s)
- Mathieu Hatt
- INSERM, UMR 1101, LaTIM, University of Brest, IBSAM, Brest, France
| | - John A Lee
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | | | | | - Curtis Caldwell
- Sunnybrook Health Sciences Center, Toronto, ON, M4N 3M5, Canada
| | | | - Wei Lu
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | - Shiva Das
- University of North Carolina, Chapel Hill, NC, 27599, USA
| | - Xavier Geets
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | - Vincent Gregoire
- Université catholique de Louvain (IREC/MIRO) & FNRS, Brussels, 1200, Belgium
| | - Robert Jeraj
- University of Wisconsin, Madison, WI, 53705, USA
| | | | | | - Ursula Nestle
- Universitätsklinikum Freiburg, Freiburg, 79106, Germany
| | - Andrei B Pugachev
- University of Texas Southwestern Medical Center, Dallas, TX, 75390, USA
| | - Heiko Schöder
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| | | | - Emiliano Spezi
- School of Engineering, Cardiff University, Cardiff, Wales, United Kingdom
| | | | - Habib Zaidi
- Geneva University Hospital, Geneva, CH-1211, Switzerland
| | - Assen S Kirov
- Memorial Sloan Kettering Cancer Center, New York, NY, 10065, USA
| |
Collapse
|
4
|
Lapuyade-Lahorgue J, Visvikis D, Pradier O, Cheze Le Rest C, Hatt M. SPEQTACLE: An automated generalized fuzzy C-means algorithm for tumor delineation in PET. Med Phys 2016; 42:5720-34. [PMID: 26429246 DOI: 10.1118/1.4929561] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/28/2022] Open
Abstract
PURPOSE Accurate tumor delineation in positron emission tomography (PET) images is crucial in oncology. Although recent methods achieved good results, there is still room for improvement regarding tumors with complex shapes, low signal-to-noise ratio, and high levels of uptake heterogeneity. METHODS The authors developed and evaluated an original clustering-based method called spatial positron emission quantification of tumor-Automatic Lp-norm estimation (SPEQTACLE), based on the fuzzy C-means (FCM) algorithm with a generalization exploiting a Hilbertian norm to more accurately account for the fuzzy and non-Gaussian distributions of PET images. An automatic and reproducible estimation scheme of the norm on an image-by-image basis was developed. Robustness was assessed by studying the consistency of results obtained on multiple acquisitions of the NEMA phantom on three different scanners with varying acquisition parameters. Accuracy was evaluated using classification errors (CEs) on simulated and clinical images. SPEQTACLE was compared to another FCM implementation, fuzzy local information C-means (FLICM) and fuzzy locally adaptive Bayesian (FLAB). RESULTS SPEQTACLE demonstrated a level of robustness similar to FLAB (variability of 14% ± 9% vs 14% ± 7%, p = 0.15) and higher than FLICM (45% ± 18%, p < 0.0001), and improved accuracy with lower CE (14% ± 11%) over both FLICM (29% ± 29%) and FLAB (22% ± 20%) on simulated images. Improvement was significant for the more challenging cases with CE of 17% ± 11% for SPEQTACLE vs 28% ± 22% for FLAB (p = 0.009) and 40% ± 35% for FLICM (p < 0.0001). For the clinical cases, SPEQTACLE outperformed FLAB and FLICM (15% ± 6% vs 37% ± 14% and 30% ± 17%, p < 0.004). CONCLUSIONS SPEQTACLE benefitted from the fully automatic estimation of the norm on a case-by-case basis. This promising approach will be extended to multimodal images and multiclass estimation in future developments.
Collapse
Affiliation(s)
| | | | - Olivier Pradier
- LaTIM, INSERM, UMR 1101, Brest 29609, France and Radiotherapy Department, CHRU Morvan, Brest 29609, France
| | - Catherine Cheze Le Rest
- DACTIM University of Poitiers, Nuclear Medicine Department, CHU Milétrie, Poitiers 86021, France
| | | |
Collapse
|
7
|
Improvement of internal tumor volumes of non-small cell lung cancer patients for radiation treatment planning using interpolated average CT in PET/CT. PLoS One 2013; 8:e64665. [PMID: 23696903 PMCID: PMC3655997 DOI: 10.1371/journal.pone.0064665] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2013] [Accepted: 04/18/2013] [Indexed: 11/19/2022] Open
Abstract
Respiratory motion causes uncertainties in tumor edges on either computed tomography (CT) or positron emission tomography (PET) images and causes misalignment when registering PET and CT images. This phenomenon may cause radiation oncologists to delineate tumor volume inaccurately in radiotherapy treatment planning. The purpose of this study was to analyze radiology applications using interpolated average CT (IACT) as attenuation correction (AC) to diminish the occurrence of this scenario. Thirteen non-small cell lung cancer patients were recruited for the present comparison study. Each patient had full-inspiration, full-expiration CT images and free breathing PET images by an integrated PET/CT scan. IACT for AC in PETIACT was used to reduce the PET/CT misalignment. The standardized uptake value (SUV) correction with a low radiation dose was applied, and its tumor volume delineation was compared to those from HCT/PETHCT. The misalignment between the PETIACT and IACT was reduced when compared to the difference between PETHCT and HCT. The range of tumor motion was from 4 to 17 mm in the patient cohort. For HCT and PETHCT, correction was from 72% to 91%, while for IACT and PETIACT, correction was from 73% to 93% (*p<0.0001). The maximum and minimum differences in SUVmax were 0.18% and 27.27% for PETHCT and PETIACT, respectively. The largest percentage differences in the tumor volumes between HCT/PET and IACT/PET were observed in tumors located in the lowest lobe of the lung. Internal tumor volume defined by functional information using IACT/PETIACT fusion images for lung cancer would reduce the inaccuracy of tumor delineation in radiation therapy planning.
Collapse
|