• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4619882)   Today's Articles (912)   Subscriber (49404)
For: Sharma D, Badal A, Badano A. hybridMANTIS: a CPU-GPU Monte Carlo method for modeling indirect x-ray detectors with columnar scintillators. Phys Med Biol 2012;57:2357-72. [PMID: 22469917 DOI: 10.1088/0031-9155/57/8/2357] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Number Cited by Other Article(s)
1
Sengupta A, Badal A, Makeev A, Badano A. Computational models of direct and indirect X-ray breast imaging detectors for in silico trials. Med Phys 2022;49:6856-6870. [PMID: 35997076 DOI: 10.1002/mp.15935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 07/27/2022] [Accepted: 07/28/2022] [Indexed: 12/13/2022]  Open
2
Virtual Clinical Trials in 2D and 3D X-ray Breast Imaging and Dosimetry: Comparison of CPU-Based and GPU-Based Monte Carlo Codes. Cancers (Basel) 2022;14:cancers14041027. [PMID: 35205775 PMCID: PMC8870739 DOI: 10.3390/cancers14041027] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Revised: 02/12/2022] [Accepted: 02/13/2022] [Indexed: 12/10/2022]  Open
3
Volken W, Zulliger MA, Koller B, Manser P, Fix MK. Investigation on the resolution of a micro cone beam CT scanner scintillating detector using Monte Carlo methods. Phys Med 2018;53:17-24. [PMID: 30241750 DOI: 10.1016/j.ejmp.2018.08.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2018] [Revised: 06/13/2018] [Accepted: 08/05/2018] [Indexed: 11/19/2022]  Open
4
Sharma D, Sempau J, Badano A. Technical Note: On the efficiency of variance reduction techniques for Monte Carlo estimates of imaging noise. Med Phys 2017;45:629-634. [DOI: 10.1002/mp.12638] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 08/30/2017] [Accepted: 10/15/2017] [Indexed: 02/06/2023]  Open
5
Roncali E, Mosleh-Shirazi MA, Badano A. Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging. Phys Med Biol 2017;62:R207-R235. [PMID: 28976914 PMCID: PMC5739055 DOI: 10.1088/1361-6560/aa8b31] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
6
Maurino SL, Badano A, Cunningham IA, Karim KS. Theoretical and Monte Carlo optimization of a stacked three-layer flat-panel x-ray imager for applications in multi-spectral medical imaging. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2016;9783:97833Z. [PMID: 28845080 PMCID: PMC5568811 DOI: 10.1117/12.2217085] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
7
Zhao C, Konstantinidis AC, Zheng Y, Anaxagoras T, Speller RD, Kanicki J. 50μm pixel pitch wafer-scale CMOS active pixel sensor x-ray detector for digital breast tomosynthesis. Phys Med Biol 2015;60:8977-9001. [DOI: 10.1088/0031-9155/60/23/8977] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
8
Nillius P, Klamra W, Sibczynski P, Sharma D, Danielsson M, Badano A. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging. Med Phys 2015;42:600-605. [DOI: 10.1118/1.4905096] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Revised: 11/16/2014] [Accepted: 12/11/2014] [Indexed: 01/12/2023]  Open
9
Dong H, Sharma D, Badano A. Web-based, GPU-accelerated, Monte Carlo simulation and visualization of indirect radiation imaging detector performance. Med Phys 2014;41:121907. [PMID: 25471967 DOI: 10.1118/1.4901516] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]  Open
10
Gutierrez B, Badano A, Samuelson F. Analytic variance estimates of Swank and Fano factors. Med Phys 2014;41:072102. [PMID: 24989397 DOI: 10.1118/1.4881328] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]  Open
11
Sharma D, Badano A. Validation of columnar CsI x-ray detector responses obtained with hybridMANTIS, a CPU-GPU Monte Carlo code for coupled x-ray, electron, and optical transport. Med Phys 2013;40:031907. [PMID: 23464322 DOI: 10.1118/1.4791642] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA