De Benetti F, Brosch-Lenz J, Guerra González JM, Uribe C, Eiber M, Navab N, Wendler T. DosePatch: physics-inspired cropping layout for patch-based Monte Carlo simulations to provide fast and accurate internal dosimetry. EJNMMI Phys 2024; 11:51. [PMID: 38922372 PMCID: PMC11208390 DOI: 10.1186/s40658-024-00646-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2023] [Accepted: 05/08/2024] [Indexed: 06/27/2024] Open
Abstract
BACKGROUND Dosimetry-based personalized therapy was shown to have clinical benefits e.g. in liver selective internal radiation therapy (SIRT). Yet, there is no consensus about its introduction into clinical practice, mainly as Monte Carlo simulations (gold standard for dosimetry) involve massive computation time. We addressed the problem of computation time and tested a patch-based approach for Monte Carlo simulations for internal dosimetry to improve parallelization. We introduce a physics-inspired cropping layout for patch-based MC dosimetry, and compare it to cropping layouts of the literature as well as dosimetry using organ-S-values, and dose kernels, taking whole-body Monte Carlo simulations as ground truth. This was evaluated in five patients receiving Yttrium-90 liver SIRT. RESULTS The patch-based Monte Carlo approach yielded the closest results to the ground truth, making it a valid alternative to the conventional approach. Our physics-inspired cropping layout and mosaicking scheme yielded a voxel-wise error of < 2% compared to whole-body Monte Carlo in soft tissue, while requiring only ≈ 10% of the time. CONCLUSIONS This work demonstrates the feasibility and accuracy of physics-inspired cropping layouts for patch-based Monte Carlo simulations.
Collapse
Affiliation(s)
- Francesca De Benetti
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Julia Brosch-Lenz
- Department of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jorge Mario Guerra González
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Carlos Uribe
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, Canada
| | - Matthias Eiber
- Department of Nuclear Medicine, Klinikum Rechts der Isar, Technical University of Munich, Munich, Germany
| | - Nassir Navab
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany
| | - Thomas Wendler
- Chair for Computer Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching, Germany.
- Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Augsburg, Augsburg, Germany.
- Institute of Digital Medicine, University Hospital Augsburg, Neusaess, Germany.
- Clinical Computational Medical Imaging Research, University of Augsburg, Augsburg, Germany.
| |
Collapse
|
2
|
Dieudonné A, Becker S, Soares M, Hollenbeck C, De Goltstein MC, Vera P, Santus R. Biological efficacy of simulated radiolabeled Lipiodol® ultra-fluid and microspheres for various beta emitters: study based on VX2 tumors. EJNMMI Res 2023; 13:101. [PMID: 37995042 PMCID: PMC10667182 DOI: 10.1186/s13550-023-01051-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/08/2023] [Indexed: 11/24/2023] Open
Abstract
BACKGROUND Radioembolization is one therapeutic option for the treatment of locally early-stage hepatocellular carcinoma. The aim of this study was to evaluate the distribution of Lipiodol® ultra-fluid and microspheres and to simulate their effectiveness with different beta emitters (90Y, 188Re, 32P, 166Ho, 131I, and 177Lu) on VX2 tumors implanted in the liver of 30 New Zealand rabbits. RESULTS Twenty-three out of 30 rabbits had exploitable data: 14 in the group that received Lipiodol® ultra-fluid (group L), 6 in the group that received microspheres (group M), and 3 in the control group (group C). The histologic analysis showed that the Lipiodol® ultra-fluid distributes homogeneously in the tumor up to 12 days after injection. The X-ray μCT images showed that Lipiodol® ultra-fluid has a more distal penetration in the tumor than microspheres. The entropy (disorder of the system) in the L group was significantly higher than in the M group (4.06 vs 2.67, p = 0.01). Equivalent uniform biological effective doses (EUBED) for a tumor-absorbed dose of 100 Gy were greater in the L group but without statistical significance except for 177Lu (p = 0.03). The radionuclides ranking by EUBED (from high to low) was 90Y, 188Re, 32P, 166Ho, 131I, and 177Lu. CONCLUSIONS This study showed a higher ability of Lipiodol® ultra-fluid to penetrate the tumor that translated into a higher EUBED. This study confirms 90Y as a good candidate for radioembolization, although 32P, 166Ho, and 188Re can achieve similar results.
Collapse
Affiliation(s)
- Arnaud Dieudonné
- Nuclear Medicine Department, Henri Becquerel Cancer Center, 76000, Rouen, France.
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France.
| | - Stéphanie Becker
- Nuclear Medicine Department, Henri Becquerel Cancer Center, 76000, Rouen, France
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
| | - Miguel Soares
- Research and Development Division, Laboratoire Guerbet, Aulnay-Sous-Bois, France
| | - Claire Hollenbeck
- Research and Development Division, Laboratoire Guerbet, Aulnay-Sous-Bois, France
| | | | - Pierre Vera
- Nuclear Medicine Department, Henri Becquerel Cancer Center, 76000, Rouen, France
- QuantIF-LITIS EA4108, University of Rouen, Rouen, France
| | - Robin Santus
- Research and Development Division, Laboratoire Guerbet, Aulnay-Sous-Bois, France
| |
Collapse
|
3
|
Chen G, Lu Z, Chen Y, Mok GSP. Voxel-S-value methods adapted to heterogeneous media for quantitative Y-90 microsphere radioembolization dosimetry. Z Med Phys 2023; 33:35-45. [PMID: 36535831 PMCID: PMC10068576 DOI: 10.1016/j.zemedi.2022.11.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2022] [Revised: 11/07/2022] [Accepted: 11/07/2022] [Indexed: 12/23/2022]
Abstract
PURPOSE The absorbed dose estimation from Voxel-S-Value (VSV) method in heterogeneous media is suboptimal as VSVs are calculated in homogeneous media. The aim of this study is to develop and evaluate new VSV methods in order to enhance the accuracy of Y-90 microspheres absorbed dose estimation in liver, lungs, tumors and lung-liver interface regions. METHODS Ten patients with Y-90 microspheres SPECT/CT and PET/CT data, six of whom had additional Tc-99m-macroaggregated albumin SPECT/CT data, were analyzed from the Deep Blue Data Repository. Seven existing VSV methods along with three newly proposed VSV methods were evaluated: liver and lung kernel with center voxel scaling (LiLuCK), liver kernel with density correction and lung kernel with center voxel scaling (LiKDLuCK), liver kernel with center voxel scaling and lung kernel with density correction (LiCKLuKD). Monte Carlo (MC) results were regarded as the gold standard. Absolute absorbed dose errors (%AADE) of these methods for the liver, lungs, tumors, upper liver, and lower lungs were assessed. RESULTS Liver and tumor's median %AADE of all methods were <3% for three types of imaging data. In the lungs, however, three recently proposed VSV methods provided median %AADEs of less than 7%, whereas the differences exceeded 20% for existing methods that did not use a lung kernel. LiCKLuKD could achieve median %AADE <2% in the liver, upper liver and tumors, and median %AADE <7% in the lungs and lower lungs in three types of data. CONCLUSION All methods are consistent with MC in the liver and tumors. Methods with tissue-specific kernel and effective correction achieve smaller errors in lungs. LiCKLuKD has comparable results with MC in absorbed dose estimation of Y-90 radioembolization for all target regions.
Collapse
Affiliation(s)
- Gefei Chen
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China
| | - Zhonglin Lu
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China; Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China
| | - Yue Chen
- Department of Nuclear Medicine, The Affiliated Hospital of Southwest Medical University, Nuclear Medicine and Molecular Imaging Key Laboratory of Sichuan Province. No. 25, Taiping St., Luzhou, Sichuan, China.
| | - Greta S P Mok
- Biomedical Imaging Laboratory (BIG), Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau SAR, China; Center for Cognitive and Brain Sciences, Institute of Collaborative Innovation, University of Macau, Taipa, Macau SAR, China; Ministry of Education Frontiers Science Center for Precision Oncology, University of Macau, Macau SAR, China.
| |
Collapse
|
4
|
Sharma NK, Kappadath SC, Chuong M, Folkert M, Gibbs P, Jabbour SK, Jeyarajah DR, Kennedy A, Liu D, Meyer JE, Mikell J, Patel RS, Yang G, Mourtada F. The American Brachytherapy Society consensus statement for permanent implant brachytherapy using Yttrium-90 microsphere radioembolization for liver tumors. Brachytherapy 2022; 21:569-591. [PMID: 35599080 PMCID: PMC10868645 DOI: 10.1016/j.brachy.2022.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/25/2022] [Accepted: 04/14/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE To develop a multidisciplinary consensus for high quality multidisciplinary implementation of brachytherapy using Yttrium-90 (90Y) microspheres transarterial radioembolization (90Y TARE) for primary and metastatic cancers in the liver. METHODS AND MATERIALS Members of the American Brachytherapy Society (ABS) and colleagues with multidisciplinary expertise in liver tumor therapy formulated guidelines for 90Y TARE for unresectable primary liver malignancies and unresectable metastatic cancer to the liver. The consensus is provided on the most recent literature and clinical experience. RESULTS The ABS strongly recommends the use of 90Y microsphere brachytherapy for the definitive/palliative treatment of unresectable liver cancer when recommended by the multidisciplinary team. A quality management program must be implemented at the start of 90Y TARE program development and follow-up data should be tracked for efficacy and toxicity. Patient-specific dosimetry optimized for treatment intent is recommended when conducting 90Y TARE. Implementation in patients on systemic therapy should account for factors that may enhance treatment related toxicity without delaying treatment inappropriately. Further management and salvage therapy options including retreatment with 90Y TARE should be carefully considered. CONCLUSIONS ABS consensus for implementing a safe 90Y TARE program for liver cancer in the multidisciplinary setting is presented. It builds on previous guidelines to include recommendations for appropriate implementation based on current literature and practices in experienced centers. Practitioners and cooperative groups are encouraged to use this document as a guide to formulate their clinical practices and to adopt the most recent dose reporting policies that are critical for a unified outcome analysis of future effectiveness studies.
Collapse
Affiliation(s)
- Navesh K Sharma
- Department of Radiation Oncology, Penn State Hershey School of Medicine, Hershey, PA
| | - S Cheenu Kappadath
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX
| | - Michael Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL
| | - Michael Folkert
- Northwell Health Cancer Institute, Radiation Medicine at the Center for Advanced Medicine, New Hyde Park, NY
| | - Peter Gibbs
- Personalised Oncology Division, Walter and Eliza Hall Institute, Melbourne, Victoria, Australia
| | - Salma K Jabbour
- Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ
| | | | | | - David Liu
- Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | | | - Rahul S Patel
- Icahn School of Medicine at Mount Sinai, New York, NY
| | - Gary Yang
- Loma Linda University, Loma Linda, CA
| | - Firas Mourtada
- Helen F. Graham Cancer Center & Research Institute, Christiana Care Health System, Newark, DE; Department of Radiation Oncology, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA.
| |
Collapse
|
5
|
Plachouris D, Mountris KA, Papadimitroulas P, Spyridonidis T, Katsanos K, Apostolopoulos D, Papathanasiou N, Hazle JD, Visvikis D, Kagadis GC. Clinical Evaluation of a Three-Dimensional Internal Dosimetry Technique for Liver Radioembolization with 90Y Microspheres Using Dose Voxel Kernels. Cancer Biother Radiopharm 2021; 36:809-819. [PMID: 33656372 DOI: 10.1089/cbr.2020.4554] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background: The purpose of this study was to develop a rapid, reliable, and efficient tool for three-dimensional (3D) dosimetry treatment planning and post-treatment evaluation of liver radioembolization with 90Y microspheres, using tissue-specific dose voxel kernels (DVKs) that can be used in everyday clinical practice. Materials and Methods: Two tissue-specific DVKs for 90Y were calculated through Monte Carlo (MC) simulations. DVKs for the liver and lungs were generated, and the dose distribution was compared with direct MC simulations. A method was developed to produce a 3D dose map by convolving the calculated DVKs with the activity biodistribution derived from clinical single-photon emission computed tomography (SPECT) or positron emission tomography (PET) images. Image registration for the SPECT or PET images with the corresponding computed tomography scans was performed before dosimetry calculation. The authors first compared the DVK convolution dosimetry with a direct full MC simulation on an XCAT anthropomorphic phantom. They then tested it in 25 individual clinical cases of patients who underwent 90Y therapy. All MC simulations were carried out using the GATE MC toolkit. Results: Comparison of the measured absorbed dose using tissue-specific DVKs and direct MC simulation on 25 patients revealed a mean difference of 1.07% ± 1.43% for the liver and 1.03% ± 1.21% for the tumor tissue, respectively. The largest difference between DVK convolution and full MC dosimetry was observed for the lung tissue (10.16% ± 1.20%). The DVK statistical uncertainty was <0.75% for both media. Conclusions: This semiautomatic algorithm is capable of performing rapid, accurate, and efficient 3D dosimetry. The proposed method considers tissue and activity heterogeneity using tissue-specific DVKs. Furthermore, this method provides results in <1 min, making it suitable for everyday clinical practice.
Collapse
Affiliation(s)
- Dimitris Plachouris
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Konstantinos A Mountris
- Department of Electrical Engineering, Aragon Institute of Engineering Research, IIS Aragon, University of Zaragoza, Zaragoza, Spain
| | | | - Trifon Spyridonidis
- Department of Nuclear Medicine, School of Medicine, University of Patras, Rion, Greece
| | | | | | | | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | | | - George C Kagadis
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
6
|
Tiwari A, Sunderland J, Graves SA, Strand S, Flynn R. Absorbed dose distributions from beta-decaying radionuclides: Experimental validation of Monte Carlo tools for radiopharmaceutical dosimetry. Med Phys 2020; 47:5779-5790. [PMID: 32955755 DOI: 10.1002/mp.14463] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2020] [Revised: 06/22/2020] [Accepted: 08/04/2020] [Indexed: 11/05/2022] Open
Abstract
PURPOSE This study aims to experimentally validate the Monte Carlo generated absorbed doses from the beta particles emitted by 90 Y and 177 Lu using radiochromic EBT3 film-based dosimetry. METHODS Line sources of 90 Y and 177 Lu were inserted longitudinally through blocks of low-density polyethylene and tissue-equivalent slabs of cortical bone and lung equivalent plastics. Radiochromic film (Gafchromic EBT3) was laser cut to accommodate orthogonal line sources of radioactivity, and the film was sandwiched intimately between the rectangular blocks to achieve charged particle equilibrium. Line sources consisted of plastic capillary tube of length (13 ± 0.1) cm, with 0.42-mm inner diameter and a wall thickness of 0.21 mm. 90 Y line sources were prepared from a solution of dissolved 90 Y resin microspheres. 177 Lu line sources were prepared from an aliquot of 177 Lu-DOTATATE. Film exposures were conducted for durations ranging from 10 min to 38 h. Radiochromic film calibration was performed by irradiation with 6-MV-bremsstrahlung x rays from a calibrated linear accelerator, in accordance with literature recommendations. Experimental geometries were precisely simulated within the GATE Monte Carlo toolkit, which has previously been used for the generation of dose point kernels. RESULTS The mean percentage difference between measured and simulated absorbed doses were 5.04% and 7.21% for 90 Y and 177 Lu beta absorbed dose in the range of (0.1-10) Gy. Additionally, 1D gamma analysis using a local 10%/1 mm gamma criterion was performed to compare the absorbed dose distributions. The percentage of measurement points passing the gamma criterion, averaged over all tests, was 93.5%. CONCLUSIONS We report the experimental validation of Monte Carlo derived beta absorbed dose distributions for 90 Y and 177 Lu, solidifying the validity of using Monte Carlo-based methods for estimating absorbed dose from beta emitters. Overall, excellent agreement was observed between the experimental beta absorbed doses in the linear region of the radiochromic film and the GATE Monte Carlo simulations demonstrating that radiochromic film dosimetry has sufficient sensitivity and spatial resolution to be used as a tool for measuring beta decay absorbed dose distributions.
Collapse
Affiliation(s)
- Ashok Tiwari
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1077, USA.,Department of Physics, University of Iowa, 203 Van Allen Hall, Iowa City, IA, 52242-1479, USA
| | - John Sunderland
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1077, USA.,Department of Physics, University of Iowa, 203 Van Allen Hall, Iowa City, IA, 52242-1479, USA
| | - Stephen A Graves
- Department of Radiology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1077, USA.,Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1089, USA
| | - Sarah Strand
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1089, USA
| | - Ryan Flynn
- Department of Radiation Oncology, University of Iowa Hospitals and Clinics, 200 Hawkins Dr., Iowa City, IA, 52242-1089, USA
| |
Collapse
|
7
|
Hermann AL, Dieudonné A, Ronot M, Sanchez M, Pereira H, Chatellier G, Garin E, Castera L, Lebtahi R, Vilgrain V. Relationship of Tumor Radiation–absorbed Dose to Survival and Response in Hepatocellular Carcinoma Treated with Transarterial Radioembolization with 90Y in the SARAH Study. Radiology 2020; 296:673-684. [DOI: 10.1148/radiol.2020191606] [Citation(s) in RCA: 70] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
8
|
St James S, Bednarz B, Benedict S, Buchsbaum JC, Dewaraja Y, Frey E, Hobbs R, Grudzinski J, Roncali E, Sgouros G, Capala J, Xiao Y. Current Status of Radiopharmaceutical Therapy. Int J Radiat Oncol Biol Phys 2020; 109:891-901. [PMID: 32805300 DOI: 10.1016/j.ijrobp.2020.08.035] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2020] [Accepted: 08/06/2020] [Indexed: 02/02/2023]
Abstract
In radiopharmaceutical therapy (RPT), a radionuclide is systemically or locally delivered with the goal of targeting and delivering radiation to cancer cells while minimizing radiation exposure to untargeted cells. Examples of current RPTs include thyroid ablation with the administration of 131I, treatment of liver cancer with 90Y microspheres, the treatment of bony metastases with 223Ra, and the treatment of neuroendocrine tumors with 177Lu-DOTATATE. New RPTs are being developed where radionuclides are incorporated into systemic targeted therapies. To assure that RPT is appropriately implemented, advances in targeting need to be matched with advances in quantitative imaging and dosimetry methods. Currently, radiopharmaceutical therapy is administered by intravenous or locoregional injection, and the treatment planning has typically been implemented like chemotherapy, where the activity administered is either fixed or based on a patient's body weight or body surface area. RPT pharmacokinetics are measurable by quantitative imaging and are known to vary across patients, both in tumors and normal tissues. Therefore, fixed or weight-based activity prescriptions are not currently optimized to deliver a cytotoxic dose to targets while remaining within the tolerance dose of organs at risk. Methods that provide dose estimates to individual patients rather than to reference geometries are needed to assess and adjust the injected RPT dose. Accurate doses to targets and organs at risk will benefit the individual patients and decrease uncertainties in clinical trials. Imaging can be used to measure activity distribution in vivo, and this information can be used to determine patient-specific treatment plans where the dose to the targets and organs at risk can be calculated. The development and adoption of imaging-based dosimetry methods is particularly beneficial in early clinical trials. In this work we discuss dosimetric accuracy needs in modern radiation oncology, uncertainties in the dosimetry in RPT, and best approaches for imaging and dosimetry of internal radionuclide therapy.
Collapse
Affiliation(s)
- Sara St James
- Department of Radiation Oncology, University of California San Francisco, San Francisco, California.
| | - Bryan Bednarz
- Department of Medical Physics and Human Oncology, University of Wisconsin School of Medicine and Public Health, Madison, Wisconsin
| | - Stanley Benedict
- Department of Radiation Oncology, University of California Davis, Sacramento, California
| | - Jeffrey C Buchsbaum
- Radiation Research Program, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, Maryland
| | - Yuni Dewaraja
- Department of Radiology, University of Michigan, Ann Arbor, Michigan
| | - Eric Frey
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Robert Hobbs
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | | | - Emilie Roncali
- Department of Radiation Oncology, University of California Davis, Sacramento, California
| | - George Sgouros
- Department of Radiology, Johns Hopkins University, Baltimore, Maryland
| | - Jacek Capala
- Radiation Research Program, Division of Cancer Treatment and Diagnosis, NCI, NIH, Bethesda, Maryland
| | - Ying Xiao
- Hospital of the University of Pennsylvania
| |
Collapse
|
9
|
Mikell JK, Dewaraja YK, Owen D. Transarterial Radioembolization for Hepatocellular Carcinoma and Hepatic Metastases: Clinical Aspects and Dosimetry Models. Semin Radiat Oncol 2020; 30:68-76. [PMID: 31727302 DOI: 10.1016/j.semradonc.2019.08.005] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Transarterial radioembolization (TARE) with Yttrium-90 (90Y) microspheres is a liver-directed therapy for primary and metastatic disease. This manuscript provides a review of the clinical literature on TARE indications and efficacy with overviews of patient-selection and toxicity. Current dosimetry models used in practice are safe, relatively simple, and easy for clinicians to use. Planning currently relies on the imperfect surrogate, 99mTc macroaggregated albumin. Post-therapy quantitative imaging (90Y SPECT/CT or 90Y PET/CT) of microspheres can be used to calculate the macroscopic in vivo absorbed dose distribution. Similar to the evolution of other brachytherapy dose calculations, TARE is moving toward more patient-specific dosimetry that includes calculating and reporting nonuniform dose distributions throughout tumors and normal uninvolved liver.
Collapse
Affiliation(s)
- Justin K Mikell
- Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, MI.
| | - Yuni K Dewaraja
- Department of Radiology, University of Michigan Medical Center, Ann Arbor, MI
| | - Dawn Owen
- Department of Radiation Oncology, University of Michigan Medical Center, Ann Arbor, MI
| |
Collapse
|
10
|
Frezza A, Joachim-Paquet C, Chauvin M, Després P. Validation of irtGPUMCD, a GPU-based Monte Carlo internal dosimetry framework for radionuclide therapy. Phys Med 2020; 73:95-104. [PMID: 32334403 DOI: 10.1016/j.ejmp.2020.04.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/31/2019] [Revised: 04/07/2020] [Accepted: 04/12/2020] [Indexed: 11/28/2022] Open
Abstract
PURPOSE Monte Carlo (MC) simulations are highly desirable for dose treatment planning and evaluation in radiation oncology. This is true also in emerging nuclear medicine applications such as internal radiotherapy with radionuclides. The purpose of this study is the validation of irtGPUMCD, a GPU-based MC code for dose calculations in internal radiotherapy. METHODS The female and male phantoms of the International Commission on Radiological Protection (ICRP 110) were used as benchmarking geometries for this study focused on 177Lu and including 99mTc and 131I. Dose calculations were also conducted for a real patient. For phantoms, twelve anatomical structures were considered as target/source organs. The S-values were evaluated with irtGPUMCD simulations (108 photons), with gamma branching ratios of ICRP 107 publication. The 177Lu electrons S-values were calculated for source organs only, based on local deposition of dose in irtGPUMCD. The S-value relative difference between irtGPUMCD and IDAC-DOSE were evaluated for all targets/sources considered. A DVHs comparison with GATE was conducted. An exponential track length estimator was introduced in irtGPUMCD to increase computational efficiency. RESULTS The relative S-value differences between irtGPUMCD and IDAC-DOSE were <5% while this comparison with GATE was <1%. The DVHs dosimetric indices comparison between GATE and irtGPUMCD for the patient led to an excellent agreement (<2%). The time required for the simulation of 108 photons was 1.5 min for the female phantom, and one minute for the real patient (<1% uncertainty). These results are promising and let envision the use of irtGPUMCD for internal dosimetry in clinical applications.
Collapse
Affiliation(s)
- Andrea Frezza
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, QC G1V 0A6, Canada
| | - Charles Joachim-Paquet
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, QC G1V 0A6, Canada
| | - Maxime Chauvin
- CRCT, UMR 1037, Inserm, Université Toulouse III Paul Sabatier, Toulouse, France
| | - Philippe Després
- Department of Physics, Engineering Physics and Optics and Cancer Research Center, Université Laval, Quebec City, QC G1V 0A6, Canada; Department of Radiation Oncology and Research Center of CHU de Québec - Université Laval, Quebec City, QC G1R 2J6, Canada.
| |
Collapse
|
11
|
Gosewisch A, Ilhan H, Tattenberg S, Mairani A, Parodi K, Brosch J, Kaiser L, Gildehaus FJ, Todica A, Ziegler S, Bartenstein P, Böning G. 3D Monte Carlo bone marrow dosimetry for Lu-177-PSMA therapy with guidance of non-invasive 3D localization of active bone marrow via Tc-99m-anti-granulocyte antibody SPECT/CT. EJNMMI Res 2019; 9:76. [PMID: 31414241 PMCID: PMC6694348 DOI: 10.1186/s13550-019-0548-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 07/30/2019] [Indexed: 11/15/2022] Open
Abstract
Background The bone marrow (BM) is a main risk organ during Lu-177-PSMA ligand therapy of metastasized castration-resistant prostate cancer (mCRPC) patients. So far, BM dosimetry relies on S values, which are pre-computed for reference anatomies, simplified activity distributions, and a physiological BM distribution. However, mCRPC patients may show a considerable bone lesion load, which leads to a heterogeneous and patient-specific activity accumulation close to BM-bearing sites. Furthermore, the patient-specific BM distribution might be significantly altered in the presence of bone lesions. The aim was to perform BM absorbed dose calculations through Monte Carlo (MC) simulations and to investigate the potential value of image-based BM localization. This study is based on 11 Lu-177-PSMA-617 therapy cycles of 10 patients (10 first cycles), who obtained a pre-therapeutic Ga-68-PSMA-11 PET/CT; quantitative Lu-177 SPECT acquisitions of the abdomen 24 (+CT), 48, and 72 h p.i.; and a Lu-177 whole-body planar acquisition at 24 h post-therapy. Patient-specific 3D volumes of interest were segmented from the Ga-68-PSMA-11 PET/CT, filled with activity information from the Lu-177 data, and imported into the FLUKA MC code together with the patient CT. MC simulations of the BM absorbed dose were performed assuming a physiological BM distribution according to the ICRP 110 reference male (MC1) or a displacement of active BM from the direct location of bone lesions (MC2). Results were compared with those from S values (SMIRD). BM absorbed doses were correlated with the decrease of lymphocytes, total white blood cells, hemoglobin level, and platelets. For two patients, an additional pre-therapeutic Tc-99m-anti-granulocyte antibody SPECT/CT was performed for BM localization. Results Median BM absorbed doses were 130, 37, and 11 mGy/GBq for MC1, MC2, and SMIRD, respectively. Significant strong correlation with the decrease of platelet counts was found, with highest correlation for MC2 (MC1: r = − 0.63, p = 0.04; MC2: r = − 0.71, p = 0.01; SMIRD: r = − 0.62, p = 0.04). For both investigated patients, BM localization via Tc-99m-anti-granulocyte antibody SPECT/CT indicated a displacement of active BM from the direct location of lesions similar to model MC2 and led to a reduction in the BM absorbed dose of 40 and 41% compared to MC1. Conclusion Higher BM absorbed doses were observed for MC-based models; however, for MC2, all absorbed doses were still below 2 Gy. MC1 resulted in critical values for some patients, but is suspected to yield strongly exaggerated absorbed doses by neglecting bone marrow displacement. Image-based BM localization might be beneficial, and future studies are recommended to support an improvement for the prediction of hematoxicities.
Collapse
Affiliation(s)
- Astrid Gosewisch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Harun Ilhan
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Sebastian Tattenberg
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Andrea Mairani
- Heidelberg Ion Beam Therapy Center, University Hospital Heidelberg, Heidelberg, Germany
| | - Katia Parodi
- Department of Medical Physics, Ludwig-Maximilians-Universität München, Garching b. München, Germany
| | - Julia Brosch
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Lena Kaiser
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Franz Josef Gildehaus
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Andrei Todica
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Sibylle Ziegler
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Peter Bartenstein
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany
| | - Guido Böning
- Department of Nuclear Medicine, University Hospital, LMU Munich, Marchioninistrasse 15, 81377, Munich, Germany.
| |
Collapse
|
12
|
Tse J, Geoghegan S. Calculations of dose point kernels of 64 Cu in different media with PENELOPE Monte Carlo code. Med Phys 2019; 46:2422-2429. [PMID: 30822361 DOI: 10.1002/mp.13465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2018] [Revised: 02/22/2019] [Accepted: 02/22/2019] [Indexed: 11/06/2022] Open
Abstract
PURPOSE The unique decay properties of copper-64 (64 Cu) has made it a radionuclide of interest in theragnostic applications of nuclear medicine. This study aims to calculate the dose point kernels (DPKs) of 64 Cu in various media with PENELOPE Monte Carlo code. METHODS Monte Carlo simulations were performed using PENELOPE code (version 2014). To calculate DPKs, the simulation comprised an isotropic point radiation source positioned at the origin of a spherical object of radius 50 cm. The absorbed dose along the radial direction outwards from the point source were scored with a resolution of 20 μm. Validations were firstly performed by calculating the DPKs of monoenergetic electrons and photons in water and the results were compared against the literature values. The continuous energy spectra of the beta minus and positron emissions from 64 Cu were numerically modeled and used as inputs to the simulation. DPKs of 64 Cu were calculated in water, soft tissue, lung tissue, and cortical bone, including all emissions types. RESULTS The simulations have been successfully validated against literature values. The largest deviations have been observed with 10 keV monoenergetic electrons with the average and maximum dose difference of -1.01% and -10.56%. The modeled energy spectra closely compared with the average energies from Brookhaven Laboratory National Nuclear Data Centre and the combined spectral shapes from the RAdiation Dose Assessment Resource (RADAR). The DPKs of 64 Cu demonstrated different radial dose deposition in different media owing to the different physical density and effective atomic number. CONCLUSIONS The DPKs of 64 Cu have been calculated with Monte Carlo simulations in four different media. They will be useful to study the dosimetric properties of 64 Cu-labeled radiopharmaceuticals and perform therapeutic dose planning.
Collapse
Affiliation(s)
- Jason Tse
- Medical Physics Department, Austin Hospital, Melbourne, VIC, Australia.,Faculty of Health Sciences, University of Sydney, Sydney, NSW, Australia
| | - Sean Geoghegan
- Department of Medical Physics, Royal Adelaide Hospital, Adelaide, SA, Australia
| |
Collapse
|
13
|
Huizing DMV, de Wit-van der Veen BJ, Verheij M, Stokkel MPM. Dosimetry methods and clinical applications in peptide receptor radionuclide therapy for neuroendocrine tumours: a literature review. EJNMMI Res 2018; 8:89. [PMID: 30159614 PMCID: PMC6115319 DOI: 10.1186/s13550-018-0443-z] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2018] [Accepted: 08/21/2018] [Indexed: 12/25/2022] Open
Abstract
Background The main challenge for systemic radiation therapy using radiopharmaceuticals (SRT) is to optimise the dose delivered to the tumour, while minimising normal tissue irradiation. Dosimetry could help to increase therapy response and decrease toxicity after SRT by individual treatment planning. Peptide receptor radionuclide therapy (PRRT) is an accepted SRT treatment option for irresectable and metastatic neuroendocrine tumours (NET). However, dosimetry in PRRT is not routinely performed, mainly due to the lack of evidence in literature and clinical implementation difficulties. The goal of this review is to provide insight in dosimetry methods and requirements and to present an overview of clinical aspects of dosimetry in PRRT for NET. Methods A PubMed query including the search criteria dosimetry, radiation dose, peptide receptor radionuclide therapy, and radionuclide therapy was performed. Articles were selected based on title and abstract, and description of dosimetric approach. Results A total of 288 original articles were included. The most important dosimetry methods, their main advantages and limitations, and implications in the clinical setting are discussed. An overview of dosimetry in clinical studies regarding PRRT treatment for NET is provided. Conclusion Clinical dosimetry in PRRT is feasible and can result in improved treatment outcomes. Current clinical dosimetry studies focus on safety and apply non-voxel-based dosimetry methods. Personalised treatment using sophisticated dosimetry methods to assess tumour and normal tissue uptake in clinical trials is the next step towards routine dosimetry in PRRT for NET. Electronic supplementary material The online version of this article (10.1186/s13550-018-0443-z) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Daphne Merel Valerie Huizing
- Department of Nuclear Medicine, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | | | - Marcel Verheij
- Department of Radiation Oncology, Netherlands Cancer Institute, Plesmanlaan 121, 1066 CX, Amsterdam, The Netherlands
| | | |
Collapse
|
14
|
Besemer AE, Yang YM, Grudzinski JJ, Hall LT, Bednarz BP. Development and Validation of RAPID: A Patient-Specific Monte Carlo Three-Dimensional Internal Dosimetry Platform. Cancer Biother Radiopharm 2018; 33:155-165. [PMID: 29694246 DOI: 10.1089/cbr.2018.2451] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
This work describes the development and validation of a patient-specific Monte Carlo internal dosimetry platform called RAPID (Radiopharmaceutical Assessment Platform for Internal Dosimetry). RAPID utilizes serial PET/CT or SPECT/CT images to calculate voxelized three-dimensional (3D) internal dose distributions with the Monte Carlo code Geant4. RAPID's dosimetry calculations were benchmarked against previously published S-values and specific absorbed fractions (SAFs) calculated for monoenergetic photon and electron sources within the Zubal phantom and for S-values calculated for a variety of radionuclides within spherical tumor phantoms with sizes ranging from 1 to 1000 g. The majority of the S-values and SAFs calculated in the Zubal Phantom were within 5% of the previously published values with the exception of a few 10 keV photon SAFs that agreed within 10%, and one value within 16%. The S-values calculated in the spherical tumor phantoms agreed within 2% for 177Lu, 131I, 125I, 18F, and 64Cu, within 3.5% for 211At and 213Bi, within 6.5% for 153Sm, 111In, 89Zr, and 223Ra, and within 9% for 90Y, 68Ga, and 124I. In conclusion, RAPID is capable of calculating accurate internal dosimetry at the voxel-level for a wide variety of radionuclides and could be a useful tool for calculating patient-specific 3D dose distributions.
Collapse
Affiliation(s)
- Abigail E Besemer
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin.,2 Department of Human Oncology, School of Medicine and Public Health, University of Wisconsin , Madison, Wisconsin
| | - You Ming Yang
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin.,3 Department of Radiation Oncology, University of California - Los Angeles , Los Angeles, California
| | - Joseph J Grudzinski
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin
| | - Lance T Hall
- 4 Department of Radiology, School of Medicine and Public Health, University of Wisconsin , Madison, Wisconsin.,5 Carbone Cancer Center, University of Wisconsin-Madison , Madison, Wisconsin
| | - Bryan P Bednarz
- 1 Department of Medical Physics, Wisconsin Institutes for Medical Research, University of Wisconsin , Madison, Wisconsin
| |
Collapse
|
15
|
Hashikin NAA, Yeong CH, Guatelli S, Abdullah BJJ, Ng KH, Malaroda A, Rosenfeld A, Perkins AC. Systematic investigation on the validity of partition model dosimetry for90Y radioembolization using Monte Carlo simulation. ACTA ACUST UNITED AC 2017; 62:7342-7356. [DOI: 10.1088/1361-6560/aa7e5b] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
16
|
Besemer AE, Titz B, Grudzinski JJ, Weichert JP, Kuo JS, Robins HI, Hall LT, Bednarz BP. Impact of PET and MRI threshold-based tumor volume segmentation on patient-specific targeted radionuclide therapy dosimetry using CLR1404. Phys Med Biol 2017; 62:6008-6025. [PMID: 28682793 DOI: 10.1088/1361-6560/aa716d] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Variations in tumor volume segmentation methods in targeted radionuclide therapy (TRT) may lead to dosimetric uncertainties. This work investigates the impact of PET and MRI threshold-based tumor segmentation on TRT dosimetry in patients with primary and metastatic brain tumors. In this study, PET/CT images of five brain cancer patients were acquired at 6, 24, and 48 h post-injection of 124I-CLR1404. The tumor volume was segmented using two standardized uptake value (SUV) threshold levels, two tumor-to-background ratio (TBR) threshold levels, and a T1 Gadolinium-enhanced MRI threshold. The dice similarity coefficient (DSC), jaccard similarity coefficient (JSC), and overlap volume (OV) metrics were calculated to compare differences in the MRI and PET contours. The therapeutic 131I-CLR1404 voxel-level dose distribution was calculated from the 124I-CLR1404 activity distribution using RAPID, a Geant4 Monte Carlo internal dosimetry platform. The TBR, SUV, and MRI tumor volumes ranged from 2.3-63.9 cc, 0.1-34.7 cc, and 0.4-11.8 cc, respectively. The average ± standard deviation (range) was 0.19 ± 0.13 (0.01-0.51), 0.30 ± 0.17 (0.03-0.67), and 0.75 ± 0.29 (0.05-1.00) for the JSC, DSC, and OV, respectively. The DSC and JSC values were small and the OV values were large for both the MRI-SUV and MRI-TBR combinations because the regions of PET uptake were generally larger than the MRI enhancement. Notable differences in the tumor dose volume histograms were observed for each patient. The mean (standard deviation) 131I-CLR1404 tumor doses ranged from 0.28-1.75 Gy GBq-1 (0.07-0.37 Gy GBq-1). The ratio of maximum-to-minimum mean doses for each patient ranged from 1.4-2.0. The tumor volume and the interpretation of the tumor dose is highly sensitive to the imaging modality, PET enhancement metric, and threshold level used for tumor volume segmentation. The large variations in tumor doses clearly demonstrate the need for standard protocols for multimodality tumor segmentation in TRT dosimetry.
Collapse
Affiliation(s)
- Abigail E Besemer
- Department of Medical Physics, University of Wisconsin-Madison, Madison, WI 53705, United States of America. Department of Human Oncology, University of Wisconsin-Madison, Madison, WI 53705, United States of America
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Khazaee Moghadam M, Kamali Asl A, Geramifar P, Zaidi H. Evaluating the Application of Tissue-Specific Dose Kernels Instead of Water Dose Kernels in Internal Dosimetry: A Monte Carlo Study. Cancer Biother Radiopharm 2017; 31:367-379. [PMID: 27996311 DOI: 10.1089/cbr.2016.2117] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE The aim of this work is to evaluate the application of tissue-specific dose kernels instead of water dose kernels to improve the accuracy of patient-specific dosimetry by taking tissue heterogeneities into consideration. MATERIALS AND METHODS Tissue-specific dose point kernels (DPKs) and dose voxel kernels (DVKs) for yttrium-90 (90Y), lutetium-177 (177Lu), and phosphorus-32 (32P) are calculated using the Monte Carlo (MC) simulation code GATE (version 7). The calculated DPKs for bone, lung, adipose, breast, heart, intestine, kidney, liver, and spleen are compared with those of water. The dose distribution in normal and tumorous tissues in lung, liver, and bone of a Zubal phantom is calculated using tissue-specific DVKs instead of those of water in conventional methods. For a tumor defined in a heterogeneous region in the Zubal phantom, the absorbed dose is calculated using a proposed algorithm, taking tissue heterogeneity into account. The algorithm is validated against full MC simulations. RESULTS The simulation results indicate that the highest differences between water and other tissue DPKs occur in bone for 90Y (12.2% ± 0.6%), 32P (18.8% ± 1.3%), and 177Lu (16.9% ± 1.3%). The second highest discrepancy corresponds to the lung for 90Y (6.3% ± 0.2%), 32P (8.9% ± 0.4%), and 177Lu (7.7% ± 0.3%). For 90Y, the mean absorbed dose in tumorous and normal tissues is calculated using tissue-specific DVKs in lung, liver, and bone. The results are compared with doses calculated considering the Zubal phantom water equivalent and the relative differences are 4.50%, 0.73%, and 12.23%, respectively. For the tumor in the heterogeneous region of the Zubal phantom that includes lung, liver, and bone, the relative difference between mean calculated dose in tumorous and normal tissues based on the proposed algorithm and the values obtained from full MC dosimetry is 5.18%. CONCLUSIONS A novel technique is proposed considering tissue-specific dose kernels in the dose calculation algorithm. This algorithm potentially enables patient-specific dosimetry and improves estimation of the average absorbed dose of 90Y in a tumor located in lung, bone, and soft tissue interface by 6.98% compared with the conventional methods.
Collapse
Affiliation(s)
| | - Alireza Kamali Asl
- 1 Department of Radiation Medicine Engineering, Shahid Beheshti University , Tehran, Iran
| | - Parham Geramifar
- 2 Research Center for Nuclear Medicine, Shariati Hospital, Tehran University of Medical Sciences , Tehran, Iran
| | - Habib Zaidi
- 3 Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital , Geneva, Switzerland .,4 Geneva Neuroscience Center, Geneva University , Geneva, Switzerland .,5 Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen , Groningen, The Netherlands
| |
Collapse
|
18
|
Sarrut D, Badel JN, Halty A, Garin G, Perol D, Cassier P, Blay JY, Kryza D, Giraudet AL. 3D absorbed dose distribution estimated by Monte Carlo simulation in radionuclide therapy with a monoclonal antibody targeting synovial sarcoma. EJNMMI Phys 2017; 4:6. [PMID: 28101733 PMCID: PMC5241566 DOI: 10.1186/s40658-016-0172-1] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2016] [Accepted: 12/28/2016] [Indexed: 11/10/2022] Open
Abstract
Backround Radiolabeled OTSA101, a monoclonal antibody targeting synovial sarcoma (SS) developed by OncoTherapy Science, was used to treat relapsing SS metastases following a theranostic procedure: in case of significant 111In-OTSA101 tumor uptake and favorable biodistribution, patient was randomly treated with 370/1110 MBq 90Y-OTSA101. Monte Carlo-based 3D dosimetry integrating time-activity curves in VOI was performed on 111In-OTSA101 repeated SPECT/CT. Estimated absorbed doses (AD) in normal tissues were compared to biological side effects and to the admitted maximal tolerated absorbed dose (MTD) in normal organs. Results in the tumors were also compared to disease evolution. Results Biodistribution and tracer quantification were analyzed on repeated SPECT/CT acquisitions performed after injection of 111In-OTSA101 in 19/20 included patients. SPECT images were warped to a common coordinates system with deformable registration. Volumes of interest (VOI) for various lesions and normal tissues were drawn on the first CT acquisition and reported to all the SPECT images. Tracer quantification and residence time of 111In-OTSA101 in VOI were used to evaluate the estimated absorbed doses per MBq of 90Y-OTSA101 by means of Monte Carlo simulations (GATE). A visual scale analysis was applied to assess tumor uptake (grades 0 to 4) and results were compared to the automated quantification. Results were then compared to biological side effects reported in the selected patients treated with 90Y-OTSA101 but also to disease response to treatment. After screening, 8/20 patients were treated with 370 or 1110 MBq 90Y-OTSA101. All demonstrated medullary toxicity, only one presented with transient grade 3 liver toxicity due to disease progression, and two patients presented with transient grade 1 renal toxicity. Median absorbed doses were the highest in the liver (median, 0.64 cGy/MBq; [0.27 −1.07]) being far lower than the 20 Gy liver MTD, and the lowest in bone marrow (median, 0.09 cGy/MBq; [0.02 −0.18]) being closer to the 2 Gy bone marrow MTD. Most of the patients demonstrated progressive disease on RECIST criteria during patient follow-up. 111In-OTSA101 tumors tracer uptake visually appeared highly heterogeneous in inter- and intra-patient analyses, independently of tumor sizes, with variable kinetics. The majority of visual grades corresponded to the automated computed ones. Estimated absorbed doses in the 95 supra-centimetric selected lesions ranged from 0.01 to 0.71 cGy per injected MBq (median, 0.22 cGy/MBq). The maximal tumor AD obtained was 11.5 Gy. Conclusions 3D dosimetry results can explain the observed toxicity and tumors response. Despite an intense visual 111In-OTSA101 liver uptake, liver toxicity was not the dose limiting factor conversely to bone marrow toxicity. Even though tumors 111In-OTSA101 avidity was visually obvious for treated patients, the low estimated tumors AD obtained by 3D dosimetry explain the lack of tumor response.
Collapse
Affiliation(s)
- David Sarrut
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, F-69008, France. .,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France.
| | | | - Adrien Halty
- Univ Lyon, INSA-Lyon, Université Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1206, Lyon, F-69008, France.,Univ Lyon, Centre Léon Bérard, Lyon, 69008, France
| | | | - David Perol
- Univ Lyon, Centre Léon Bérard, Lyon, 69008, France
| | | | | | - David Kryza
- Univ Lyon, Université Lyon 1, CNRS, LAGEP UMR 5007, Lyon, F-69008, France.,Hospices Civils de Lyon, Imthernat plateform, Lyon, F-69008, France
| | | |
Collapse
|
19
|
Mikell JK, Mahvash A, Siman W, Baladandayuthapani V, Mourtada F, Kappadath SC. Selective Internal Radiation Therapy With Yttrium-90 Glass Microspheres: Biases and Uncertainties in Absorbed Dose Calculations Between Clinical Dosimetry Models. Int J Radiat Oncol Biol Phys 2016; 96:888-896. [PMID: 27623307 DOI: 10.1016/j.ijrobp.2016.07.021] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 06/03/2016] [Accepted: 07/18/2016] [Indexed: 01/04/2023]
Abstract
PURPOSE To quantify differences that exist between dosimetry models used for 90Y selective internal radiation therapy (SIRT). METHODS AND MATERIALS Retrospectively, 37 tumors were delineated on 19 post-therapy quantitative 90Y single photon emission computed tomography/computed tomography scans. Using matched volumes of interest (VOIs), absorbed doses were reported using 3 dosimetry models: glass microsphere package insert standard model (SM), partition model (PM), and Monte Carlo (MC). Univariate linear regressions were performed to predict mean MC from SM and PM. Analysis was performed for 2 subsets: cases with a single tumor delineated (best case for PM), and cases with multiple tumors delineated (typical clinical scenario). Variability in PM from the ad hoc placement of a single spherical VOI to estimate the entire normal liver activity concentration for tumor (T) to nontumoral liver (NL) ratios (TNR) was investigated. We interpreted the slope of the resulting regression as bias and the 95% prediction interval (95%PI) as uncertainty. MCNLsingle represents MC absorbed doses to the NL for the single tumor patient subset; other combinations of calculations follow a similar naming convention. RESULTS SM was unable to predict MCTsingle or MCTmultiple (p>.12, 95%PI >±177 Gy). However, SMsingle was able to predict (p<.012) MCNLsingle, albeit with large uncertainties; SMsingle and SMmultiple yielded biases of 0.62 and 0.71, and 95%PI of ±40 and ± 32 Gy, respectively. PMTsingle and PMTmultiple predicted (p<2E-6) MCTsingle and MCTmultiple with biases of 0.52 and 0.54, and 95%PI of ±38 and ± 111 Gy, respectively. The TNR variability in PMTsingle increased the 95%PI for predicting MCTsingle (bias = 0.46 and 95%PI = ±103 Gy). The TNR variability in PMTmultiple modified the bias when predicting MCTmultiple (bias = 0.32 and 95%PI = ±110 Gy). CONCLUSIONS The SM is unable to predict mean MC tumor absorbed dose. The PM is statistically correlated with mean MC, but the resulting uncertainties in predicted MC are large. Large differences observed between dosimetry models for 90Y SIRT warrant caution when interpreting published SIRT absorbed doses. To reduce uncertainty, we suggest the entire NL VOI be used for TNR estimates when using PM.
Collapse
Affiliation(s)
- Justin K Mikell
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas
| | - Armeen Mahvash
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Wendy Siman
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas
| | - Veera Baladandayuthapani
- The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas; Department of Biostatistics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Firas Mourtada
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; Department of Radiation Oncology, Christiana Care, Newark, Delaware; Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, Pennsylvania
| | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, Texas.
| |
Collapse
|
20
|
|
21
|
Mikell J, Cheenu Kappadath S, Wareing T, Erwin WD, Titt U, Mourtada F. Evaluation of a deterministic grid-based Boltzmann solver (GBBS) for voxel-level absorbed dose calculations in nuclear medicine. Phys Med Biol 2016; 61:4564-82. [DOI: 10.1088/0031-9155/61/12/4564] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
22
|
Sanchez-Garcia M, Gardin I, Lebtahi R, Dieudonné A. Implementation and validation of collapsed cone superposition for radiopharmaceutical dosimetry of photon emitters. Phys Med Biol 2015; 60:7861-76. [PMID: 26406778 DOI: 10.1088/0031-9155/60/20/7861] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Two collapsed cone (CC) superposition algorithms have been implemented for radiopharmaceutical dosimetry of photon emitters. The straight CC (SCC) superposition method uses a water energy deposition kernel (EDKw) for each electron, positron and photon components, while the primary and scatter CC (PSCC) superposition method uses different EDKw for primary and once-scattered photons. PSCC was implemented only for photons originating from the nucleus, precluding its application to positron emitters. EDKw are linearly scaled by radiological distance, taking into account tissue density heterogeneities. The implementation was tested on 100, 300 and 600 keV mono-energetic photons and (18)F, (99m)Tc, (131)I and (177)Lu. The kernels were generated using the Monte Carlo codes MCNP and EGSnrc. The validation was performed on 6 phantoms representing interfaces between soft-tissues, lung and bone. The figures of merit were γ (3%, 3 mm) and γ (5%, 5 mm) criterions corresponding to the computation comparison on 80 absorbed doses (AD) points per phantom between Monte Carlo simulations and CC algorithms. PSCC gave better results than SCC for the lowest photon energy (100 keV). For the 3 isotopes computed with PSCC, the percentage of AD points satisfying the γ (5%, 5 mm) criterion was always over 99%. A still good but worse result was found with SCC, since at least 97% of AD-values verified the γ (5%, 5 mm) criterion, except a value of 57% for the (99m)Tc with the lung/bone interface. The CC superposition method for radiopharmaceutical dosimetry is a good alternative to Monte Carlo simulations while reducing computation complexity.
Collapse
Affiliation(s)
- Manuel Sanchez-Garcia
- APHP-Service de médecine nucléaire, Hôpital Beaujon, F-92110 Clichy, France. INSERM U1149, Clichy, France
| | | | | | | |
Collapse
|
23
|
Mikell JK, Mahvash A, Siman W, Mourtada F, Kappadath SC. Comparing voxel-based absorbed dosimetry methods in tumors, liver, lung, and at the liver-lung interface for (90)Y microsphere selective internal radiation therapy. EJNMMI Phys 2015; 2:16. [PMID: 26501817 PMCID: PMC4538912 DOI: 10.1186/s40658-015-0119-y] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2015] [Accepted: 07/07/2015] [Indexed: 11/08/2022] Open
Abstract
Background To assess differences between four different voxel-based dosimetry methods (VBDM) for tumor, liver, and lung absorbed doses following 90Y microsphere selective internal radiation therapy (SIRT) based on 90Y bremsstrahlung SPECT/CT, a secondary objective was to estimate the sensitivity of liver and lung absorbed doses due to differences in organ segmentation near the liver-lung interface. Methods Investigated VBDM were Monte Carlo (MC), soft-tissue kernel with density correction (SKD), soft-tissue kernel (SK), and local deposition (LD). Seventeen SIRT cases were analyzed. Mean absorbed doses (\documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯) were calculated for tumor, non-tumoral liver (NL), and right lung (RL). Simulations with various SPECT spatial resolutions (FHWMs) and multiple lung shunt fractions (LSs) estimated the accuracy of VBDM at the liver-lung interface. Sensitivity of patient RL and NL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ on segmentation near the interface was assessed by excluding portions near the interface. Results SKD, SK, and LD were within 5 % of MC for tumor and NL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯. LD and SKD overestimated RL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ compared to MC on average by 17 and 20 %, respectively; SK underestimated RL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ on average by −60 %. Simulations (20 mm FWHM, 20 % LS) showed that SKD, LD, and MC were within 10 % of the truth deep (>39 mm) in the lung; SK significantly underestimated the absorbed dose deep in the lung by approximately −70 %. All VBDM were within 10 % of truth deep (>12 mm) in the liver. Excluding 1, 2, and 3 cm of RL near the interface changed the resulting RL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ by −22, −38, and −48 %, respectively, for all VBDM. An average change of −7 % in the NL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ was realized when excluding 3 cm of NL from the interface. \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ was realized when excluding 3 cm of NL from the interface. Conclusions SKD, SK, and LD are equivalent to MC for tumor and NL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯. SK underestimates RL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ relative to MC whereas LD and SKD overestimate. RL \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$ \overline{AD} $$\end{document}AD¯ is strongly influenced by the liver-lung interface.
Collapse
Affiliation(s)
- Justin K Mikell
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, TX, 77030, USA.,The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| | - Armeen Mahvash
- Department of Interventional Radiology, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
| | - Wendy Siman
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, TX, 77030, USA.,The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA
| | | | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1155 Pressler St, Unit 1352, Houston, TX, 77030, USA. .,The University of Texas Graduate School of Biomedical Sciences at Houston, Houston, TX, USA.
| |
Collapse
|
24
|
O' Doherty J. A review of 3D image-based dosimetry, technical considerations and emerging perspectives in 90Y microsphere therapy. ACTA ACUST UNITED AC 2015; 2:1-34. [PMID: 27182449 DOI: 10.17229/jdit.2015-0428-016] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Yttrium-90 radioembolization (90Y-RE) is a well-established therapy for the treatment of hepatocellular carcinoma (HCC) and also of metastatic liver deposits from other malignancies. Nuclear Medicine and Cath Lab diagnostic imaging takes a pivotal role in the success of the treatment, and in order to fully exploit the efficacy of the technique and provide reliable quantitative dosimetry that are related to clinical endpoints in the era of personalized medicine, technical challenges in imaging need to be overcome. In this paper, the extensive literature of current 90Y-RE techniques and challenges facing it in terms of quantification and dosimetry are reviewed, with a focus on the current generation of 3D dosimetry techniques. Finally, new emerging techniques are reviewed which seek to overcome these challenges, such as high-resolution imaging, novel surgical procedures and the use of other radiopharmaceuticals for therapy and pre-therapeutic planning.
Collapse
Affiliation(s)
- Jim O' Doherty
- PET Imaging Centre, Division of Imaging Sciences and Biomedical Engineering, King's College London, King's Health Partners, St. Thomas' Hospital, London, United Kingdom
| |
Collapse
|