1
|
Almashakbeh Y, Shamimi H, Faris IH, Cortés JM, Callejas A, Rus G. Healthy human skin Kelvin-Voigt fractional and spring-pot biomarkers reconstruction using torsional wave elastography. Phys Eng Sci Med 2024; 47:575-587. [PMID: 38319472 PMCID: PMC11166795 DOI: 10.1007/s13246-024-01387-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Accepted: 01/07/2024] [Indexed: 02/07/2024]
Abstract
This paper presents a novel method for reconstructing skin parameters using Probabilistic Inverse Problem (PIP) techniques and Torsional Wave Elastography (TWE) rheological modeling. A comprehensive examination was conducted to compare and analyze the theoretical, time-of-flight (TOF), and full-signal waveform (FSW) approaches. The objective was the identification of the most effective method for the estimation of mechanical parameters. Initially, the most appropriate rheological model for the simulation of skin tissue behavior was determined through the application and comparison of two models, spring pot (SP) and Kevin Voigt fractional derivative (KVFD). A numerical model was developed using the chosen rheological models. The collection of experimental data from 15 volunteers utilizing a TWE sensor was crucial for obtaining significant information for the reconstruction process. The study sample consisted of five male and ten female subjects ranging in age from 25 to 60 years. The procedure was performed on the ventral forearm region of the participants. The process of reconstructing skin tissue parameters was carried out using PIP techniques. The experimental findings were compared with the numerical results. The three methods considered (theoretical, TOF, FSW) have been used. The efficacy of TOF and FSW was then compared with theoretical method. The findings of the study demonstrate that the FSW and TOF techniques successfully reconstructed the parameters of the skin tissue in all of the models. The SP model's the skin tissue η values ranged from 8 to 12 P a · s , as indicated by the TOF reconstruction parameters. η values found by the KVFD model ranged from 4.1 to 9.3 P a · s . The μ values generated by the KVFD model range between 0.61 and 96.86 kPa. However, FSW parameters reveal that skin tissue η values for the SP model ranged from 7.8 to 12 P a · s . The KVFD model determined η values between 6.3 and 9.5 P a · s . The KVFD model presents μ values ranging between 26.02 and 122.19 kPa. It is shown that the rheological model that best describes the nature of the skin is the SP model and its simplicity as it requires only two parameters, in contrast to the three parameters required by the KVFD model. Therefore, this work provides a valuable addition to the area of dermatology, with possible implications for clinical practice.
Collapse
Affiliation(s)
- Yousef Almashakbeh
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain.
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain.
| | - Hirad Shamimi
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain
| | - Inas H Faris
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain
- Excellence Research Unit,"Modelling Nature" (MNat), University of Granada, 18071, Granada, Spain
| | - José M Cortés
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain
| | - Antonio Callejas
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain
| | - Guillermo Rus
- Department of Structural Mechanics, University of Granada, 18071, Granada, Spain
- Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012, Granada, Spain
- Excellence Research Unit,"Modelling Nature" (MNat), University of Granada, 18071, Granada, Spain
| |
Collapse
|
2
|
Rus G, Faris IH, Torres J, Callejas A, Melchor J. Why Are Viscosity and Nonlinearity Bound to Make an Impact in Clinical Elastographic Diagnosis? SENSORS (BASEL, SWITZERLAND) 2020; 20:E2379. [PMID: 32331295 PMCID: PMC7219338 DOI: 10.3390/s20082379] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2020] [Revised: 04/17/2020] [Accepted: 04/20/2020] [Indexed: 12/24/2022]
Abstract
The adoption of multiscale approaches by the biomechanical community has caused a major improvement in quality in the mechanical characterization of soft tissues. The recent developments in elastography techniques are enabling in vivo and non-invasive quantification of tissues' mechanical properties. Elastic changes in a tissue are associated with a broad spectrum of pathologies, which stems from the tissue microstructure, histology and biochemistry. This knowledge is combined with research evidence to provide a powerful diagnostic range of highly prevalent pathologies, from birth and labor disorders (prematurity, induction failures, etc.), to solid tumors (e.g., prostate, cervix, breast, melanoma) and liver fibrosis, just to name a few. This review aims to elucidate the potential of viscous and nonlinear elastic parameters as conceivable diagnostic mechanical biomarkers. First, by providing an insight into the classic role of soft tissue microstructure in linear elasticity; secondly, by understanding how viscosity and nonlinearity could enhance the current diagnosis in elastography; and finally, by compounding preliminary investigations of those elastography parameters within different technologies. In conclusion, evidence of the diagnostic capability of elastic parameters beyond linear stiffness is gaining momentum as a result of the technological and imaging developments in the field of biomechanics.
Collapse
Affiliation(s)
- Guillermo Rus
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
- Excellence Research Unit “ModelingNature” MNat UCE.PP2017.03, University of Granada, 18071 Granada, Spain
| | - Inas H. Faris
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Jorge Torres
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Antonio Callejas
- Ultrasonics Group (TEP-959), Department of Structural Mechanics, University of Granada, 18071 Granada, Spain; (G.R.); (I.H.F.); (A.C.)
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
| | - Juan Melchor
- Biomechanics Group (TEC-12), Instituto de Investigación Biosanitaria, ibs.GRANADA, 18012 Granada, Spain;
- Excellence Research Unit “ModelingNature” MNat UCE.PP2017.03, University of Granada, 18071 Granada, Spain
- Department of Statistics and Operations Research, University of Granada, 18071 Granada, Spain
| |
Collapse
|
3
|
Viscoelastic Biomarkers of Ex Vivo Liver Samples via Torsional Wave Elastography. Diagnostics (Basel) 2020; 10:diagnostics10020111. [PMID: 32092900 PMCID: PMC7168906 DOI: 10.3390/diagnostics10020111] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2019] [Revised: 01/15/2020] [Accepted: 02/14/2020] [Indexed: 12/20/2022] Open
Abstract
The clinical ultrasound community demands mechanisms to obtain the viscoelastic biomarkers of soft tissue in order to quantify the tissue condition and to be able to track its consistency. Torsional Wave Elastography (TWE) is an emerging technique proposed for interrogating soft tissue mechanical viscoelastic constants. Torsional waves are a particular configuration of shear waves, which propagate asymmetrically in-depth and are radially transmitted by a disc and received by a ring. This configuration is shown to be particularly efficient in minimizing spurious p-waves components and is sensitive to mechanical constants, especially in cylinder-shaped organs. The objective of this work was to validate (TWE) technique against Shear Wave Elasticity Imaging (SWEI) technique through the determination of shear wave velocity, shear moduli, and viscosity of ex vivo chicken liver samples and tissue mimicking hydrogel phantoms. The results of shear moduli for ex vivo liver tissue vary 1.69–4.0kPa using TWE technique and 1.32–4.48kPa using SWEI technique for a range of frequencies from 200 to 800Hz. Kelvin–Voigt viscoelastic parameters reported values of μ = 1.51kPa and η = 0.54Pa·s using TWE and μ = 1.02kPa and η = 0.63Pa·s using SWEI. Preliminary results show that the proposed technique successfully allows reconstructing shear wave velocity, shear moduli, and viscosity mechanical biomarkers from the propagated torsional wave, establishing a proof of principle and warranting further studies.
Collapse
|
4
|
Performance Study of a Torsional Wave Sensor and Cervical Tissue Characterization. SENSORS 2017; 17:s17092078. [PMID: 28891995 PMCID: PMC5621116 DOI: 10.3390/s17092078] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/28/2017] [Revised: 09/07/2017] [Accepted: 09/08/2017] [Indexed: 02/03/2023]
Abstract
A novel torsional wave sensor designed to characterize mechanical properties of soft tissues is presented in this work. Elastography is a widely used technique since the 1990s to map tissue stiffness. Moreover, quantitative elastography uses the velocity of shear waves to achieve the shear stiffness. This technique exhibits significant limitations caused by the difficulty of the separation between longitudinal and shear waves and the pressure applied while measuring. To overcome these drawbacks, the proposed torsional wave sensor can isolate a pure shear wave, avoiding the possibility of multiple wave interference. It comprises a rotational actuator disk and a piezoceramic receiver ring circumferentially aligned. Both allow the transmission of shear waves that interact with the tissue before being received. Experimental tests are performed using tissue mimicking phantoms and cervical tissues. One contribution is a sensor sensitivity study that has been conducted to evaluate the robustness of the new proposed torsional wave elastography (TWE) technique. The variables object of the study are both the applied pressure and the angle of incidence sensor–phantom. The other contribution consists of a cervical tissue characterization. To this end, three rheological models have fit the experimental data and a static independent testing method has been performed. The proposed methodology permits the reconstruction of the mechanical constants from the propagated shear wave, providing a proof of principle and warranting further studies to confirm the validity of the results.
Collapse
|
5
|
Torsional Ultrasound Sensor Optimization for Soft Tissue Characterization. SENSORS 2017; 17:s17061402. [PMID: 28617353 PMCID: PMC5492724 DOI: 10.3390/s17061402] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 06/08/2017] [Accepted: 06/09/2017] [Indexed: 11/25/2022]
Abstract
Torsion mechanical waves have the capability to characterize shear stiffness moduli of soft tissue. Under this hypothesis, a computational methodology is proposed to design and optimize a piezoelectrics-based transmitter and receiver to generate and measure the response of torsional ultrasonic waves. The procedure employed is divided into two steps: (i) a finite element method (FEM) is developed to obtain a transmitted and received waveform as well as a resonance frequency of a previous geometry validated with a semi-analytical simplified model and (ii) a probabilistic optimality criteria of the design based on inverse problem from the estimation of robust probability of detection (RPOD) to maximize the detection of the pathology defined in terms of changes of shear stiffness. This study collects different options of design in two separated models, in transmission and contact, respectively. The main contribution of this work describes a framework to establish such as forward, inverse and optimization procedures to choose a set of appropriate parameters of a transducer. This methodological framework may be generalizable for other different applications.
Collapse
|
6
|
Ouared A, Kazemirad S, Montagnon E, Cloutier G. Ultrasound viscoelasticity assessment using an adaptive torsional shear wave propagation method. Med Phys 2016; 43:1603. [PMID: 27036560 DOI: 10.1118/1.4942813] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Abstract
PURPOSE Different approaches have been used in dynamic elastography to assess mechanical properties of biological tissues. Most techniques are based on a simple inversion based on the measurement of the shear wave speed to assess elasticity, whereas some recent strategies use more elaborated analytical or finite element method (FEM) models. In this study, a new method is proposed for the quantification of both shear storage and loss moduli of confined lesions, in the context of breast imaging, using adaptive torsional shear waves (ATSWs) generated remotely with radiation pressure. METHODS A FEM model was developed to solve the inverse wave propagation problem and obtain viscoelastic properties of interrogated media. The inverse problem was formulated and solved in the frequency domain and its robustness to noise and geometric constraints was evaluated. The proposed model was validated in vitro with two independent rheology methods on several homogeneous and heterogeneous breast tissue-mimicking phantoms over a broad range of frequencies (up to 400 Hz). RESULTS Viscoelastic properties matched benchmark rheology methods with discrepancies of 8%-38% for the shear modulus G' and 9%-67% for the loss modulus G″. The robustness study indicated good estimations of storage and loss moduli (maximum mean errors of 19% on G' and 32% on G″) for signal-to-noise ratios between 19.5 and 8.5 dB. Larger errors were noticed in the case of biases in lesion dimension and position. CONCLUSIONS The ATSW method revealed that it is possible to estimate the viscoelasticity of biological tissues with torsional shear waves when small biases in lesion geometry exist.
Collapse
Affiliation(s)
- Abderrahmane Ouared
- Laboratory of Biorheology and Medical Ultrasonics, University of Montréal Hospital Research Center (CRCHUM), Montréal, Québec H2X 0A9, Canada and Institute of Biomedical Engineering, University of Montréal, Montréal, Québec H3T 1J4, Canada
| | - Siavash Kazemirad
- Laboratory of Biorheology and Medical Ultrasonics, University of Montréal Hospital Research Center (CRCHUM), Montréal, Québec H2X 0A9, Canada
| | - Emmanuel Montagnon
- Laboratory of Biorheology and Medical Ultrasonics, University of Montréal Hospital Research Center (CRCHUM), Montréal, Québec H2X 0A9, Canada
| | - Guy Cloutier
- Laboratory of Biorheology and Medical Ultrasonics, University of Montréal Hospital Research Center (CRCHUM), Montréal, Québec H2X 0A9, Canada; Department of Radiology, Radio-Oncology and Nuclear Medicine, University of Montréal, Montréal, Québec H3T 1J4, Canada; and Institute of Biomedical Engineering, University of Montréal, Montréal, Québec H3T 1J4, Canada
| |
Collapse
|