De Saint-Hubert M, Caprioli M, de Freitas Nascimento L, Delombaerde L, Himschoot K, Vandenbroucke D, Leblans P, Crijns W. New optically stimulated luminescence dosimetry film optimized for energy dependence guided by Monte Carlo simulations. Phys Med Biol 2024; 69:075005. [PMID: 38394683 DOI: 10.1088/1361-6560/ad2ca2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Accepted: 02/23/2024] [Indexed: 02/25/2024]
Abstract
Optically stimulated luminescence (OSL) film dosimeters, based on BaFBr:Eu2+phosphor material, have major dosimetric advantages such as dose linearity, high spatial resolution, film re-usability, and immediate film readout. However, they exhibit an energy-dependent over-response at low photon energies because they are not made of tissue-equivalent materials. In this work, the OSL energy-dependent response was optimized by lowering the phosphor grain size and seeking an optimal choice of phosphor concentration and film thickness to achieve sufficient signal sensitivity. This optimization process combines measurement-based assessments of energy response in narrow x-ray beams with various energy response calculation methods applied to different film metrics. Theoretical approaches and MC dose simulations were used for homogeneous phosphor distributions and for isolated phosphor grains of different dimensions, where the dose in the phosphor grain was calculated. In total 8 OSL films were manufactured with different BaFBr:Eu2+median particle diameters (D50): 3.2μm, 1.5μm and 230 nm and different phosphor concentrations (1.6%, 5.3% and 21.3 %) and thicknesses (from 5.2 to 49μm). Films were irradiated in narrow x-ray spectra (N60, N80, N-150 and N-300) and the signal intensity relative to the nominal dose-to-water value was normalized to Co-60. Finally, we experimentally tested the response of several films in Varian 6MV TrueBeam STx linear accelerator using the following settings: 10 × 10 cm2field, 0deggantry angle, 90 cm SSD, 10 cm depth. The x-ray irradiation experiment reported a reduced energy response for the smallest grain size with an inverse correlation between response and grain size. The N-60 irradiation showed a 43% reduction in the energy over-response when going from 3μm to 230 nm grain size for the 5% phosphor concentration. Energy response calculation using a homogeneous dispersion of the phosphor underestimated the experimental response and was not able to obtain the experimental correlation between grain size and energy response. Isolated grain size modeling combined with MC dose simulations allowed to establish a good agreement with experimental data, and enabled steering the production of optimized OSL-films. The clinical 6 MV beam test confirmed a reduction in energy dependence, which is visible in small-grain films where a decrease in out-of-field over-response was observed.
Collapse
Affiliation(s)
| | - Marco Caprioli
- Department of Oncology, KU Leuven, Herestraat 49, Leuven, Belgium
| | | | - Laurence Delombaerde
- Department of Oncology, KU Leuven, Herestraat 49, Leuven, Belgium
- Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, Leuven, B-3000, Belgium
| | - Katleen Himschoot
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Dirk Vandenbroucke
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Paul Leblans
- Corporate Innovation Office, Agfa N.V., Septestraat 27, Mortsel, B-2640, Belgium
| | - Wouter Crijns
- Department of Radiation Oncology, University Hospitals Leuven, Herestraat 49, Leuven, B-3000, Belgium
| |
Collapse
|
2
|
Bossin L, Plokhikh I, Christensen JB, Gawryluk DJ, Kitagawa Y, Leblans P, Tanabe S, Vandenbroucke D, Yukihara EG. Addressing Current Challenges in OSL Dosimetry Using MgB 4O 7:Ce,Li: State of the Art, Limitations and Avenues of Research. MATERIALS (BASEL, SWITZERLAND) 2023; 16:3051. [PMID: 37109886 PMCID: PMC10142933 DOI: 10.3390/ma16083051] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Revised: 03/29/2023] [Accepted: 04/03/2023] [Indexed: 06/19/2023]
Abstract
The objective of this work is to review and assess the potential of MgB4O7:Ce,Li to fill in the gaps where the need for a new material for optically stimulated luminescence (OSL) dosimetry has been identified. We offer a critical assessment of the operational properties of MgB4O7:Ce,Li for OSL dosimetry, as reviewed in the literature and complemented by measurements of thermoluminescence spectroscopy, sensitivity, thermal stability, lifetime of the luminescence emission, dose response at high doses (>1000 Gy), fading and bleachability. Overall, compared with Al2O3:C, for example, MgB4O7:Ce,Li shows a comparable OSL signal intensity following exposure to ionizing radiation, a higher saturation limit (ca 7000 Gy) and a shorter luminescence lifetime (31.5 ns). MgB4O7:Ce,Li is, however, not yet an optimum material for OSL dosimetry, as it exhibits anomalous fading and shallow traps. Further optimization is therefore needed, and possible avenues of investigation encompass gaining a better understanding of the roles of the synthesis route and dopants and of the nature of defects.
Collapse
Affiliation(s)
- Lily Bossin
- Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland (E.G.Y.)
| | - Igor Plokhikh
- Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland (E.G.Y.)
- Laboratory for Multiscale Materials Experiments, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Jeppe Brage Christensen
- Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland (E.G.Y.)
| | - Dariusz Jakub Gawryluk
- Laboratory for Multiscale Materials Experiments, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland
| | - Yuuki Kitagawa
- National Institute of Advanced Industrial Science and Technology (AIST), Ikeda, Osaka 563-8577, Japan
| | - Paul Leblans
- Radiology Division, Agfa NV, 2640 Mortsel, Belgium
| | - Setsuhisa Tanabe
- Graduate School of Human and Environmental Studies, Kyoto University, Kyoto 606-8501, Japan
| | | | - Eduardo Gardenali Yukihara
- Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen, Switzerland (E.G.Y.)
| |
Collapse
|
3
|
|
4
|
Yukihara EG, Kron T. APPLICATIONS OF OPTICALLY STIMULATED LUMINESCENCE IN MEDICAL DOSIMETRY. RADIATION PROTECTION DOSIMETRY 2020; 192:122-138. [PMID: 33412585 DOI: 10.1093/rpd/ncaa213] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/15/2020] [Revised: 11/15/2020] [Accepted: 11/23/2020] [Indexed: 06/12/2023]
Abstract
If the first decade of the new millennium saw the establishment of a more solid foundation for the use of the Optically Stimulated Luminescence (OSL) in medical dosimetry, the second decade saw the technique take root and become more widely used in clinical studies. Recent publications report not only characterization and feasibility studies of the OSL technique for various applications in radiotherapy and radiology, but also the practical use of OSL for postal audits, estimation of staff dose, in vivo dosimetry, dose verification and dose mapping studies. This review complements previous review papers and reports on the topic, providing a panorama of the new advances and applications in the last decade. Attention is also dedicated to potential future applications, such as LET dosimetry, 2D/3D dosimetry using OSL, dosimetry in magnetic resonance imaging-guided radiotherapy (MRIgRT) and dosimetry of extremely high dose rates (FLASH therapy).
Collapse
Affiliation(s)
- Eduardo G Yukihara
- Department of Radiation Safety and Security, Paul Scherrer Institute, 5200 Villigen, Switzerland
| | - Tomas Kron
- Department of Physical Sciences, Peter MacCallum Cancer Centre, 3000 Melbourne, Australia
| |
Collapse
|
5
|
Shrestha N, Yukihara E, Cusumano D, Placidi L. Al2O3:C and Al2O3:C,Mg optically stimulated luminescence 2D dosimetry applied to magnetic resonance guided radiotherapy. RADIAT MEAS 2020. [DOI: 10.1016/j.radmeas.2020.106439] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
6
|
OSL using a prototype fibre-mounted sensor and automated reader assembly. Radiat Phys Chem Oxf Engl 1993 2020. [DOI: 10.1016/j.radphyschem.2019.108464] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
|
7
|
Souza LF, Novais AL, Antonio PL, Caldas LV, Souza DN. Luminescent properties of MgB4O7:Ce,Li to be applied in radiation dosimetry. Radiat Phys Chem Oxf Engl 1993 2019. [DOI: 10.1016/j.radphyschem.2019.108353] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
8
|
Nascimento L, Crijns W, Goveia G, Mirotta Z, Souza L, Vanhavere F, Saldarriaga Vargas C, De Saint-Hubert M. 2D reader for dose mapping in radiotherapy using radiophotoluminescent films. RADIAT MEAS 2019. [DOI: 10.1016/j.radmeas.2019.106202] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
9
|
Kalita JM, Chithambo ML. A COMPARATIVE STUDY OF THE DOSIMETRIC FEATURES OF α-Al2O3:C,Mg AND α-Al2O3:C. RADIATION PROTECTION DOSIMETRY 2017; 177:261-271. [PMID: 28398501 DOI: 10.1093/rpd/ncx039] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Accepted: 03/14/2017] [Indexed: 06/07/2023]
Abstract
A comparative study of the dosimetric features of α-Al2O3:C,Mg and α-Al2O3:C relevant to thermoluminescence dosimetry is reported. A glow curve of α-Al2O3:C,Mg measured at 1°C/s after beta irradiation to 1 Gy shows two subsidiary peaks at 42°C (labelled as I) and 72°C (II) and the main peak at 161°C (III) whereas a glow curve of α-Al2O3:C measured under the same conditions shows the main peak at 178°C (II') and a lower intensity peak at 48°C (I'). Apart from these ones, there are several other peaks at temperatures beyond that of the main peak in both α-Al2O3:C,Mg and α-Al2O3:C. However, the latter are not included in this study. We report a comparative quantitative analysis of dose response and fading of peaks I, II and III of α-Al2O3:C,Mg and peaks I' and II' of α-Al2O3:C. Analysis shows that the dose response of peaks I and III is sublinear within 1-10 Gy whereas that of peak II is superlinear within 1-4 Gy followed by a sublinear region within 4-10 Gy. In comparison, the dose response of peak I' is superlinear within 1-4 Gy followed by a sublinear region within 4-10 Gy whereas that of peak II' is sublinear within 1-4 Gy followed by a superlinear region within 4-10 Gy. As regards to fading corresponding to 1 Gy, peak I is very unstable and fades within 300 s, peak II is more stable and takes up to 43200 s to fade. In comparison, peak III fades down to 30% of its initial intensity within 2400 s. Interestingly, between 2400 and 800 s, the intensity fades by 17% only. Regarding fading in α-Al2O3:C, peak I' fades within 600 s whereas peak II' shows an inverse fading behaviour up to 64800 s. The rate of fading for peaks I, II and III in α-Al2O3:C,Mg was found to decrease with increase in dose. However, no such behaviour was observed in α-Al2O3:C. The fading in both samples is discussed on the basis of a charge hopping mechanism.
Collapse
Affiliation(s)
- J M Kalita
- Department of Physics and Electronics, Rhodes University, P O Box 94, Grahamstown 6140, South Africa
| | - M L Chithambo
- Department of Physics and Electronics, Rhodes University, P O Box 94, Grahamstown 6140, South Africa
| |
Collapse
|
10
|
Ahmed M, Shrestha N, Ahmad S, Schnell E, Akselrod M, Yukihara E. Demonstration of 2D dosimetry using Al 2 O 3 optically stimulated luminescence films for therapeutic megavoltage x-ray and ion beams. RADIAT MEAS 2017. [DOI: 10.1016/j.radmeas.2017.04.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
11
|
On the sensitivity of thermally and optically stimulated luminescence of α-Al 2 O 3 :C and α-Al 2 O 3 :C,Mg. RADIAT MEAS 2017. [DOI: 10.1016/j.radmeas.2017.03.006] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|