1
|
Trotter M, Borst N, Thewes R, von Stetten F. Review: Electrochemical DNA sensing – Principles, commercial systems, and applications. Biosens Bioelectron 2020; 154:112069. [DOI: 10.1016/j.bios.2020.112069] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Revised: 01/28/2020] [Accepted: 02/01/2020] [Indexed: 02/06/2023]
|
2
|
Makiyan F, Rahimi F, Hajati M, Shafiekhani A, Rezayan AH, Ansari-Pour N. Label-free discrimination of single nucleotide changes in DNA by reflectometric interference Fourier transform spectroscopy. Colloids Surf B Biointerfaces 2019; 181:714-720. [PMID: 31228854 DOI: 10.1016/j.colsurfb.2019.05.066] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2019] [Revised: 05/12/2019] [Accepted: 05/26/2019] [Indexed: 10/26/2022]
Abstract
Phenotypic variation - such as disease susceptibility and differential drug response - has a strong genetic component. Substantial effort has therefore been made to identify causal genomic variants explaining such variation among humans. Point mutations (PMs), which are single nucleotide changes in the genome, have been identified to be the most abundant form of causal genomic variants, making them useful, reliable diagnostic markers. Methods developed to genotype PMs have moved towards solid-phase assays, which not only show greater sensitivity and specificity, but also enable scalability and faster processing time. Most current assays are, however, based on fluorescent probes, which makes them relatively expensive. To develop a more cost-effective label-free genotyping method, we used a porous silicon (PSi) base as an efficient support for DNA biosensing and coupled it with reflectometric interference Fourier transform spectroscopy (RIFTS). To assess the versatility of this approach, we tested both a single nucleotide substitution in VKORC1 (-1639G > A; rs9923231) and a single nucleotide insertion in BRCA1 (5382insC; rs80357906). We demonstrate that the PSi-RIFTS method can efficiently detect both PM types with high sensitivity where hybridization of complementary DNA can be quantifiably differentiated from mismatch and non-complementary hybridization events. In addition, we show that the PSi base with immobilized DNA not only can be re-used to type further samples, but it also remains stable for 14 days, suggesting its potential for high-throughput applications.
Collapse
Affiliation(s)
- Farideh Makiyan
- Division of Nanobiotechnology, Department of Life Sciences Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Fereshteh Rahimi
- Division of Nanobiotechnology, Department of Life Sciences Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran.
| | - Marziyeh Hajati
- Division of Nanobiotechnology, Department of Life Sciences Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Azizollah Shafiekhani
- Physics Department, Alzahra University, Tehran, Iran; School of Physics, Institute for Research in Fundamental Sciences, Tehran, Iran
| | - Ali Hossein Rezayan
- Division of Nanobiotechnology, Department of Life Sciences Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran
| | - Naser Ansari-Pour
- Division of Biotechnology, Department of Life Sciences Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran, Iran; Big Data Institute, Nuffield Department of Medicine, University of Oxford, Oxford, UK.
| |
Collapse
|
3
|
Pérez J, Dulay S, Mir M, Samitier J. Molecular architecture for DNA wiring. Biosens Bioelectron 2018; 121:54-61. [PMID: 30196048 DOI: 10.1016/j.bios.2018.08.050] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2018] [Revised: 08/14/2018] [Accepted: 08/21/2018] [Indexed: 10/28/2022]
Abstract
Detection of the hybridisation events is of great importance in many different biotechnology applications such as diagnosis, computing, molecular bioelectronics, and among others. However, one important drawback is the low current of some redox reporters that limits their application. This paper demonstrates the powerful features of molecular wires, in particular the case of S-[4-[2-[4-(2-Phenylethynyl)phenyl]ethynyl]phenyl] thiol molecule and the key role that play the nanometric design of the capture probe linkers to achieve an efficient couple of the DNA complementary ferrocene label with the molecular wire for an effective electron transfer in co-immobilised self-assembled monolayers (SAMs) for DNA hybridisation detection. In this article, the length of the linker capture probe was studied for electron transfer enhancement from the ferrocene-motifs of immobilised molecules towards the electrode surface to obtain higher kinetics in the presence of thiolated molecular wires. The use of the right couple of capture probe linker and molecular wire has found to be beneficial as it helps to amplify eightfold the signal obtained.
Collapse
Affiliation(s)
- Judit Pérez
- Nanobioengineering group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona 08028, Spain
| | - Samuel Dulay
- Nanobioengineering group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona 08028, Spain
| | - Mònica Mir
- Nanobioengineering group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona 08028, Spain; Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Monforte de Lemos 3-5. Pabellón 11, 28029 Madrid, Spain; Department of Electronics and Biomedical engineering, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain.
| | - Josep Samitier
- Nanobioengineering group, Institute for Bioengineering of Catalonia (IBEC) Barcelona Institute of Science and Technology (BIST), 12 Baldiri Reixac 15-21, Barcelona 08028, Spain; Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Monforte de Lemos 3-5. Pabellón 11, 28029 Madrid, Spain; Department of Electronics and Biomedical engineering, University of Barcelona, Martí i Franquès 1, 08028 Barcelona, Spain
| |
Collapse
|
4
|
Adzhri R, Md Arshad M, Gopinath SC, Ruslinda A, Fathil M, Ayub R, Nor MNM, Voon C. High-performance integrated field-effect transistor-based sensors. Anal Chim Acta 2016; 917:1-18. [DOI: 10.1016/j.aca.2016.02.042] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2015] [Revised: 02/24/2016] [Accepted: 02/25/2016] [Indexed: 12/18/2022]
|
5
|
Electrical sensing of DNA-hybridization using two-port network based on suspended carbon nanotube membrane. Biomed Microdevices 2015; 17:103. [DOI: 10.1007/s10544-015-0009-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
6
|
Zaffino RL, Galan T, Pardo WA, Mir M, Samitier J. Nanoprobes for enhanced electrochemical DNA sensors. WILEY INTERDISCIPLINARY REVIEWS-NANOMEDICINE AND NANOBIOTECHNOLOGY 2015; 7:817-27. [DOI: 10.1002/wnan.1344] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/05/2015] [Accepted: 03/07/2015] [Indexed: 11/05/2022]
Affiliation(s)
- Rosa Letizia Zaffino
- Nanobioengineering Laboratory; Institute for Bioengineering of Catalonia (IBEC); Barcelona Spain
- Department of Electronics; Barcelona University (UB); Barcelona Spain
| | - Teresa Galan
- Nanobioengineering Laboratory; Institute for Bioengineering of Catalonia (IBEC); Barcelona Spain
- Department of Electronics; Barcelona University (UB); Barcelona Spain
| | - Wilmer Alfonso Pardo
- Nanobioengineering Laboratory; Institute for Bioengineering of Catalonia (IBEC); Barcelona Spain
- Department of Electronics; Barcelona University (UB); Barcelona Spain
| | - Mònica Mir
- Nanobioengineering Laboratory; Institute for Bioengineering of Catalonia (IBEC); Barcelona Spain
- Centro de Investigación Biomédica en Red de Bioingeniería; Biomateriales y Nanomedicina (CIBER-BBN); Zaragoza Spain
| | - Josep Samitier
- Nanobioengineering Laboratory; Institute for Bioengineering of Catalonia (IBEC); Barcelona Spain
- Department of Electronics; Barcelona University (UB); Barcelona Spain
- Centro de Investigación Biomédica en Red de Bioingeniería; Biomateriales y Nanomedicina (CIBER-BBN); Zaragoza Spain
| |
Collapse
|
7
|
Karsten SL, Tarhan MC, Kudo LC, Collard D, Fujita H. Point-of-care (POC) devices by means of advanced MEMS. Talanta 2015; 145:55-9. [PMID: 26459443 DOI: 10.1016/j.talanta.2015.04.032] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2015] [Accepted: 04/12/2015] [Indexed: 12/21/2022]
Abstract
Microelectromechanical systems (MEMS) have become an invaluable technology to advance the development of point-of-care (POC) devices for diagnostics and sample analyses. MEMS can transform sophisticated methods into compact and cost-effective microdevices that offer numerous advantages at many levels. Such devices include microchannels, microsensors, etc., that have been applied to various miniaturized POC products. Here we discuss some of the recent advances made in the use of MEMS devices for POC applications.
Collapse
Affiliation(s)
- Stanislav L Karsten
- NeuroInDx, Inc., E. 28th Street, Signal Hill, CA 90755, USA; Center for International Research on MicroMechatronics, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan.
| | - Mehmet C Tarhan
- Center for International Research on MicroMechatronics, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; LIMMS/CNRS-IIS (UMI 2820), The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| | - Lili C Kudo
- NeuroInDx, Inc., E. 28th Street, Signal Hill, CA 90755, USA
| | - Dominique Collard
- Center for International Research on MicroMechatronics, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan; LIMMS/CNRS-IIS (UMI 2820), The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| | - Hiroyuki Fujita
- Center for International Research on MicroMechatronics, Institute of Industrial Science, The University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan
| |
Collapse
|